WIRELESS SMOKE/HEAT/FREEZE ALARM


INSTALL INSTRUCTIONS
FCCID:ZFHSMKT3345
IndustryCanadaID:9640ASMKT3345

2GIGsWirelessSmoke/Heat/FreezeAlarmisa3xAAAbatterypoweredwirelessalarmintended
foruseina2GIGsystem.Thealarmhasabuiltinwirelesstransmitter,whichcommunicates
withthe2GIGControlPanel.Whensmoke,excessiveheatorcoldisdetected,thealarmsounds
aloudlocalalarmandthebuiltintransmittersendsasignaltotheControlPanel.Thisalarmis
designedtoprovideprotectionwithina35footradiusoftheunit.The2GIGSMTK3345can
sendalarm,tamperandbatteryconditionmessagestotheControlPanel.

Box Contents
WirelessSmoke/HeatAlarm
Packofscrewsandfixings
3AAAEnergizerE92batteries(1.5V1100mAh)orequivalent
TheWirelessSmoke/HeatAlarmcontainsasounderthatgeneratestheASHIs3.41temporal3
patterninanalarmcondition.
Inalarm,amessageisalsosenttotheControlPanelandthealarmszonetypeandnameare
displayedatthepanel.Duringanalarmcondition,pressingthealarmshushbuttonsilencesthe
sounder.TricoloredLED(red,yellow,green)andasounderonthealarmprovidelocalvisualand
audibleindicationofthealarmsstatus.
Afterpoweruphascompletedandthealarmisfunctioningnormally,thegreenLEDblinksevery12
seconds.
AlarmTrouble:Whenthealarmhasageneralfault,theyellowLEDblinksonceeveryfourseconds
andthereisachirpevery48seconds.After4hoursthe2GIGControlPaneldisplaysalossof
supervisionmessage.
AlarmDirtyFeature:Whenthealarmhasbeencontaminated,theyellowLEDblinksonceevery8
secondsandthereisachirpevery48seconds.After4hoursthe2GIGControlPaneldisplaysaloss
ofsupervisionmessage.
LowBatteryDetection:TheWirelessSmoke/HeatAlarmispoweredby3AAAbatteries.Thealarm
regularlychecksforalowbattery.Ifalowbatteryisdetected,thetransmittersendsalowbattery
messagetothe2GIGControlPanel,thatdisplaysthealarmsIDatlowbattery.Inaddition,the
yellowLEDofthealarmblinksevery12seconds.Thealarmssounderchirpsevery48seconds
(yellowLEDcontinuestoblink)untilthebatteriesarereplaced.Pressingthehushbuttonsilences
thechirpingfor12hoursifnoothertroubleconditionsexist.Replacethebatterieswhenthe
chirpingbegins.Replacetheoldbatterieswithnewones.
Ifyouareexperiencinglowbatteryissues,checktomakesurethatyouhavethecorrectbatteries
installed(3AAAEnergizerE92).

Programming
Thefollowingstepsdescribegeneralguidelinesforprogramming(learning)theWireless
Smoke/HeatAlarm(2GIGSMKT3345)intothe2GIGControlPanel.Scrollbetweenoptions
usingtheandarrows.Movetothepreviousornextpromptbypressingtheand
arrows.FormoredetailsregardinghowtoprogramtheControlPanel,refertothe2GIG
ControlPanelInstallGuide.
1. SelectRFsensor#(01to48).AssigntheWirelessSmoke/HeatAlarmtoanewzone.
2. SelectRFsensortype.
(09)24hourfire(recommendedforsmokeandfire)
(16)24hourfirewithverification(optional)
(23)noresponsetype(optionalwithfreeze)
3. SelectRFequipmenttype.
4. SelectRFsensorequipmentcode.Enter1058fortheSMKT33452GIGSmoke/HeatAlarm.
5. EnterRFsensorserialnumber(7digits).
ManualEntry:Typeinthelast7digitsoftheTXIDthatisfoundoutsidetheboxoronthe
bottomoftheheadunitbyremovingthebase.
AutoEntry:WiththepanelinLearninmode(pressShiftthenLearn)causeatamperonthe
alarmbytwistingthebaseunitcounterclockwiseandremovingit.ThecorrectTXIDshould
appear.AcceptthecorrectTXIDbypressingok.
Remembertopressthearrowtocontinuethroughthesystemconfigurationprompts.
6. SelectRFsensorequipmentage.
(0)new(productisnew)
(1)existing(productalreadyexists).
7. SelectRFsensorloopnumber.Selectwhichloopyouwouldliketosetup.
(1)Smoke
(2)Heat
(3)Freeze
NOTE:Eachloopmustbesetupasadifferentzone.Ifyouwanttoutilizeallthreefeatures
(smoke,heat,freeze)youwillneedtosetupthreedifferentzonesanduseeachloop.
8. SelectRFsensor1dialerdelay
(0)disabled(thereshouldneverbeadialerdelayonthistypeofalarm)
9. ConstructRFsensordescriptor.PressInsertthenpressanynumberbetween002and255to
addaword.Forexample,ifyouwantedtonamethisalarmassmokealarm,pressInsertthen
press208forSMOKE.PressInsertthenpress005forALARM.
10. SelectRFsensorreports(0to1).
(0)disabled(sensordoesnotreporttocentralstation)
(1)enabled(sensorreportstothecentralstation)
11. SelectRFsensorsupervised(0to1).
(0)disabled(sensordoesnotreportlossofsupervisionorlowbattery)
(1)enabled(sensorreportslossofsupervisionorlowbattery)
12. SelectRFsensorchime(0to13).
(0)disabled(panelwillnotchimewhensensorisactivated)
(1)(13)(selectsavoiceandchimetosoundwhensensorisactivated)
13. Toprogramanothersensor,clicknext.
14. Toexitprogramming,clickskipthenendandexit.Uponexit,thepaneltakesafewsecondsto
reset.

Testing
Beforetesting,putthepanelintotestmodesothecentralstationisnotnotifiedtoprevent
unwantedalarms.TestingthealarmactivatesanalarmsoundandsendsasignaltotheControl
Panel.Thetestfunctioncannotbeusedifthealarmhasatroublecondition.

Testalarmsounder,LEDsandtransmitter
1.HoldtheTestbuttonfor4beeps(approximately6seconds).
2.ReleasetheTestbutton.
3.Oncereleased,theproductwillcontinuetobeep5moretimes.Beforethebeepsstop,a
signalwillbesenttriggeringthealarm.

SmokeTest
Holdacottonwickatthesideofthealarmandgentlyblowsmokethroughthealarmuntilthe
smoketriggersthealarm.Youcanalsousesmokeaerosol.

DirectHeatTest(UseHairDryer10001500Watts)
Directheattowardthealarm.Holdtheheatsourceabout12inchesfromthealarmtoavoid
damagetotheplastic.Thealarmresetsonlyafterithastimetocool.

Ifanalarmfailsanyofthesetests,seeMaintenanceforhowtocleanthealarm.

Mounting the Alarm


1.

Seethediagramtoinstallthemountingbaseontheceilingoronthewall.Usethe2screwsand
anchorsprovided.Maneuverthebasesothescrewsareattheelbowofthescrewslotsand
secure.
2. Fitthealarminsidethebasebyaligningitoverthebaseasshown(alarmsalignmentnotch
shouldbeslightlyoffsetfromthemountingbasetamperreleasetab),thenturnthealarm
clockwiseuntilthealarmclicksintothebase.

Inserting and Replacing Batteries


1.
2.
3.
4.
5.

Removethealarmfromitsbasebytwistingtheitcounterclockwise.Removeanddisposeof
thebatteriesaccordingtoyourlocalregulations.
Toensureproperpowerdownsequence,waitaminimumof20secondsbefore
insertingnewbatteries.
Insert3AAAEnergizerE92batteriesinthebatterycompartment.Followthepolaritydiagram
insidethecompartment.Ifthebatteriesareinsertedincorrectly,removegentlywithanon
conductivetoolandcorrectlyreinsert.
Reinstallthealarmontothemountingbasebyturningthealarmclockwiseuntilthemating
marksalign.
Afterthepowerupsequence,thegreenLEDshouldblinkaboutonceevery12secondsto
indicatenormaloperation.Ifthebatteriesarenotinsertedcorrectly,thealarmwillnotoperate
andthebatteriesmaybedamaged.Ifthealarmdoesnotpowerup,checkforcorrectbattery
insertionandforfullychargedbatteries.

Constantexposuretohighhumiditymayreducebatterylife.

NFPA Recommended Locations for Alarm

AccordingtotheNationalFireProtectionAssociation(NFPA)themajorthreatfromfireina
dwellingunitoccursatnightwheneveryoneisasleep.Theprincipalthreattopersonsin
sleepingareascomesfromfiresintheremainderofthehouse;thereforesmokealarmsare
bestlocatedbetweenthebedroomareasandtherestofthehouse.
WhereNOTtoinstalltheAlarm
Directlyaboveasink,cooker,stoveoroven
Donotlocatealarmwithin5feet(1.5m)ofanycookingappliance
Nexttoadoororwindowthatwouldbeaffectedbydrafts(extractorfanorairvent)
Outside
Inorbelowacupboard
Whereairflowwouldbeobstructedbycurtainsorfurniture
Wheredirtordustcouldcollectandblockthesensor
Whereitcouldbeknocked,damaged,orinadvertentlyremoved

DoNOTINSTALLthisalarminalocationwherethenormalambienttemperatureis
below40F(4.4C)orwhereitexceeds100F(37.8C)
INSTALLthisequipmentinaccordancewiththeNationalFireProtectionAssociation(NFPA)72.

Maintenance
Cleanthealarmonceayear.Tocleanthealarm,removeitfromthemountingbase.Youcan
cleantheinteriorusingcompressedairoravacuumcleaner.Bloworvacuumthroughthe
openingsaroundtheperimeterofthealarm.Theoutsideofthealarmcanbewipedwitha
dampcloth.Aftercleaning,testthealarmbypushingtheTestbutton.Ifcleaningdoesnot
restorethealarmtonormaloperationyouneedtoreplacethealarm.

WARNING:READTHEFOLLOWINGCAREFULLY

NFPA72states:Firewarningequipmentforresidentialoccupanciesarecapableof
protectingabout50%oftheoccupantsinpotentiallyfatalfires.Victimsincludethe
elderly,children,andthephysicallyormentallyimpaired.Victimsincludeanyperson
thatcannotescapeevenwhenwarnedearlyenoughthatescapeshouldbepossible.For
thesepeople,otherstrategiessuchasprotectioninplaceorassistedrescueorescape
wouldbenecessary.
StudiesshowthatSmoke/HeatAlarmsmaynotawakenallsleepingindividuals.Itisthe
responsibilityofindividualsinthehouseholdthatarecapableofassistingothersto
provideassistancetothosewhomaynotbeawakenedbytheaudiblealarmorthose
whomaybeincapableofsafelyevacuatingtheareaunassisted.
Abatterypoweredalarmmusthavethespecificbatterytypeinstalled,beingood
condition,andbemountedproperly.
Theuseofalcoholordrugsmayalsoimpaironesabilitytoheartheaudiblealarm.For
maximumprotection,ensurethatanaudiblealarmisinstalledoneveryfloorofthe
home.
Smoke/HeatAlarmsonlyprovideprotectiontotheresidenceifsmokeactuallyreaches
thealarm.TheSmoke/HeatAlarmisnotasubstituteforaninsurancepolicy.
Homeownersandrentersshouldhaveadequateinsurancetoprotecttheirproperties.

Safety Tips

MakeaFamilyEscapePlan.Drawamapofyourhomeshowingalldoorsandwindows.
Discusstheplanwitheveryoneinthehome.
Knowatleast2waysoutofeveryroom,ifpossible.Makesurealldoorsthatleadtothe
outsideofhomeopeneasily.
Haveanoutsidemeetingplace,likealightpole,mailbox,ortreeasafedistancefromthe
residencewhereeveryonemeets.
PracticeyourFamilyEscapePlanorFireDrillatnightandduringthedayatleasttwicea
year.Onlypracticewheneverymemberofthehousecanattend.
Practiceusingdifferentwaysout,ifpossible.
Teachyourchildrenhowtoescapeontheirownincaseyoucannothelpthem.
Closedoorsbehindyouasyouleave.

Family Escape Plan


AccordingtotheNationalFireProtectionAssociation(NFPA)thereoftenisverylittle
timebetweenthedetectionofafireandthetimeitbecomesdeadly.Thisintervalcanbe
aslittleas1minute.Planningandpracticingforfireconditionswithafocusonrapidexit
fromtheresidenceareimportant!Firedrillsshouldbeheldsothatallfamilymembers
knowtheactiontobetaken.

If the Alarm Sounds


Getoutandstayout.Nevergobackinsideforpeopleorpets.
Ifyouhavetoescapethroughsmoke,getlowandgounderthesmoke.
Callthefiredepartmentfromoutsideyourhome.
FORMORESAFETYINFORMATIONSEE:www.nfpa.org/education

Specifications
TransmitterFrequency
TransmitterFrequencyTolerance
TransmitterBandwidth
ModulationType
UniqueIDCodes
SupervisoryInterval
Dimensions
Weight(includingbatteries)
Color
SpacingRating
AudibleSignal(ANSITemporal3)
Sensitivity
MaxCurrent
AlarmCurrent
SupervisoryCurrent
OperatingTemperature
RelativeHumidity
Batteries(included)
RegulatoryListing
Warranty
IncludedAccessories

345.00MHz(crystalcontrolled)
+15kHz
24kHz
AmplitudeShiftKeyingOn/OffKeying(ASKOOK)
Over1billiondifferentcodecombinations
70minutes
.5x2.5high(125mmx63mmhigh)
8.57oz(243g)
White
70ft
85dBAmin.inalarm
.53.5%/foot
50mA
20mA
25uA
40100F(4.437.8C)
1590%NonCondensing
3AAAEnergizerE92orequivalent
UL217
2years
MountingHardwarePackage

Regulatory Information
ThisdevicecomplieswithPart15oftheFCC'sRules.Operationissubjecttothefollowing
twoconditions:
1 Thisdevicemaynotcauseharmfulinterference,and
2 Thisdevicemustacceptanyinterferencereceived,includinginterferencethatmay
causeundesiredoperation.
ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigital
device,pursuanttoPart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonable
protectionagainstharmfulinterferenceinaresidentialinstallation.
Thisequipmentgenerates,usesandcanradiateradiofrequencyenergyand,ifnotinstalled
andusedinaccordancewiththeinstructions,maycauseharmfulinterferencetoradio
communications.However,thereisnoguaranteethatinterferencewillnotoccurina
particularinstallation.Ifthisequipmentdoescauseharmfulinterferencetoradioor
televisionreception,whichcanbedeterminedbyturningtheequipmentoffandon,the
userisencouragedtotrytocorrecttheinterferencebyoneormoreofthefollowing
measures:
Reorientorrelocatethereceivingantenna.
Increasetheseparationbetweentheequipmentandreceiver.
Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthe
receiverisconnected.
Consultthedealeroranexperiencedradio/TVtechnicianforhelp.
ThisproductcomplieswithFCCradiationexposurelimitsforanuncontrolledenvironment.
Avoidoperatingthisproductatadistancelessthan20cmfromtheuser.
Caution:Anychangedormodificationsnotexpresslyapprovedbythepartyresponsiblefor
compliancecouldvoidtheuser'sauthoritytooperatethisequipment.

IC approval
ThisdevicecomplieswithIndustryCanadalicenseexemptRSSstandard(s).Operationis
subjecttothefollowingtwoconditions:(1)thisdevicemaynotcauseinterference,and(2)
thisdevicemustacceptanyinterference,includinginterferencethatmaycauseundesired
operationofthedevice.
RGLEMENTATIONIC:CetappareilestconformeavecIndustrieCanadaexemptsdelicense
standardRSS(s).L'oprationestsoumiseauxdeuxconditionssuivantes:(1)cetappareilne
peutcauserd'interfrences,et(2)cetappareildoitacceptertouteinterfrence,ycompris
lesinterfrencesquipeuventcauserunmauvaisfonctionnementdul'appareil.
CetquipementestconformeauxlimitesICexpositionaurayonnementpourun
environnementnoncontrl.Cetquipementdoittreinstalletutilisavecdistance
minimumde20cmentrel'utilisateuretl'lmentrayonnantdel'appareil.
Remarque:lefabricantn'estpasresponsabledesinterfrencesradiooutlvisioncauspar
desmodificationsnonautorisesdecetquipement.Unetellemodificationpourrait
annulerl'autoritdel'utilisateurd'exploitercetquipement.
ThisClassBdigitalapparatuscomplieswithCanadianICES003
CetappareilnumriquedeclasseBestconformeIanormeNMB003duCanada.

LIMITED WARRANTY
This2GIGTechnologiesproductiswarrantedagainstdefectsinmaterialandworkmanship
for1year.Thiswarrantyextendsonlytowholesalecustomerswhobuydirectfrom2GIG
Technologiesorthrough2GIGTechnologiesnormaldistributionchannels.2GIG
Technologiesdoesnotwarrantthisproducttoconsumers.Consumersshouldinquirefrom
theirsellingdealerastothenatureofthedealerswarranty,ifany.
Therearenoobligationsorliabilitiesonthepartof2GIGTechnologiesforconsequential
damagesarisingoutoforinconnectionwithuseorperformanceofthisproductorother
indirectdamageswithrespecttolossofproperty,revenue,orprofit,orcostofremoval,
installation,orreinstallation.Allimpliedwarrantiesforfunctionality,arevalidonlyuntilthe
warrantyexpires.This2GIGTechnologiesWarrantyisinlieuofallotherwarrantiesexpressed
orimplied.

For technical support in the USA and Canada


855-2GIG-TECH (855-244-4832)
For technical support outside of the USA and Canada
Contact your regional distributor
Visit 2gig.com for a list of distributors in your region