Sei sulla pagina 1di 4

SL.

No
1

Item

BOM
Technical Specification

DC Capacity
Module Capacity
Inverter Output Power
Solar Modules-Crystalline

Inverters-with Negative Grounding Kit

MPPT Controler inverter 750 kW with associated control and


protection devices integrated to convert DC Power into 3 Phase
AC voltage, along with grid synchronizing facility - voltages 380
Volt AC(+15% to -10%) 3 Phase 50 Hz, Peak Effficiency > 98%,
THD < 3%

Module Mounting Structures - Pre/Post Galvanized and


support pads complete with module mounting assembly.

Module Mounting Structures - Pre/Post Galvanized. Design as per


IS code of wind speed of that perticular area. Electro galvanized
nuts and bolt. Design life should be more than 25 Years and
minimum yield strength of 340 MPA.

16 Channel String Combiner Boxes and terminal lugs for 4 Outdoor installation, UV resistant, glass fibre reinfiorsed plastic,
Sq.mm solar cable
self extinguishing, halogen free, IP-55 or Higher (IEC 60529),
Voltage grade 650V with earthing stud with self locking door
handle, for mounting on rail or cage clamp type suitable for
conductor sizes 2.5,4,6,10,16,32,64,100,120,240 mm cable inlet
and outlet as per requirement. Facility for providing fuses for
individual circuites, surge arresters & blocking diodes as required

Cable Connectors (MC4 male & female)

1000V (IEC/CEI),600V (UL), With safety clip that requires a tool to


unlock (NEC2008 compliant) Certified for applications with
modules according to IEC 61730, Safety class II,Directive
2002/95/EC on the restriction of the use of certain hazardous
substances in electrical and electronic equipment -with Minimal
voltage drop, High current-carrying capacity,Minimal power loss,
Minimal contact resistance,High durability contacts withstand up
to 1 million mating cycles, Operating temperatures up to
350C,higher temperatures permitted for short
periods

7
(i)

POWER AND CONTROL CABLES:-ESTIMATION


DC-LT Cables
1CX4mmsq. (Solar)-Cu

Single-pole, double insulated solar cable with fine-wire copper


strand. TV certified according to the latest regulations. -40C to
+120C (permanent) UV, ozone and hydrolysis-resistant.

(ii)

1CX120 mmsq.(SCB to Inverter)-Al

(iii)

1CX300mmsq. (Inverter to Transformer)-Al

LT Power Cable will be 1.1 kV, Armoured or unarmoured,


unearthed grade, double core/multi-core, stranded Al conductor
as mentioned, XLPE insulated with PVC outer sheath made on PVC
compound. Cable will be direct burried in case of Armoured cable
and will be laid under HDPE pipes if unarmoured. All other details
will be as Indian Standards .IEC 60189: IS 694/ IS 1554/IS/IEC
69948

Crystalline silicon power module with OC Voltage~37.7 V, Isc~8.5


Amp, Vmp~30.9V, Imp~8.1 Amp

Make

Unit

Quantity

Canadian Solar/CNPV

Watt
Watt
Watt
Nos.

11000000
300
750000
36666

TMEIC

Nos.

14

Custom Made

MW

11.0

Trinity/Hensel/Statcon or eq.

Nos.

116

Lapp/Reputed or eq.

Nos.

1924

Advance Cables/KEI/Polycab or eq

Mtrs

154000

Havelles/Advance/RPG/Polycab or eq.

Mtrs

24200

Havelles/Advance/RPG/Polycab or eq.

Mtrs

3360

SL. No
1

Item

Technical Specification

OIL FILLED POWER TRANSFORMERS:


i).380/.380/33kV
800/800/1600 kVA ONAN, Off -Load T/C, with cable terminations on LT
side and bare bushing on HT side.

i) .380/.380/33 KV
800/800/1600 kVA ONAN, Dy11y11 Off -Load T/C, Z = 5 %, 3 Phase 50 Hz class A
insulation, outdoor type for 50C ambient complete with bushings and cable
boxes, with cable terminations on both LT side and bare bushing on HT side.

ii).380/33 kV
800 kVA ONAN, Off -Load T/C, with cable terminations on LT side and
bare bushing on HT side.

ii) .380/33 KV
800 kVA ONAN, Dy11 Off -Load T/C, Z = 5 %, 3 Phase 50 Hz class A insulation,
outdoor type for 50C ambient complete with bushings and cable boxes, with
cable terminations on both LT side and bare bushing on HT side.

ii) Auxiliary Transformer

33/.4 KV Aux. Transformer, 25 kVA, outdoor type with cable terminations on LT


side and Bushing on HT Side.

33 kV VCB Panels for 33kv incoming/outgoing feeders with


Control and Auxiliary cable and their end termination kits

For 33kV outgoing feeders, complete with Outdoor circuit breakers, CT-PT set,
indication meters for current, voltage, power factor and energy, with outdoor C&R
panel with protection relays for grid and internal faults, fully wired with
annunciation and DC fail protection associated auxiliary contects and open close
switches with earthing facility, having annunciation windows and hooter facility.

LA, Isolator and HG Fuse with supply and foundation of 2 Pole


Structure

30 KA LA and 630 A Isolator and HG Fuse of suitable current rating mounted on


lattice structure

SCADA SYSTEM to control and monitor complete plant


parameters and operate the system from remote and Other
Accessories

The system will be controlled from the main control room where all the data from
different parts of the plant will be received, analyzed and action taken either
manually or on auto as per the system design.The scada should have remote
monitoring capability.

FOC Cable for SCADA


POWER CABLES:A. LT Cables
Al Cable 3.5Cx50 sqmm Armoured (Aux Xmer to Inverter Room)
Copper Cable 3Cx2.5sqmm Armoured
Copper Cable 4Cx2.5sqmm Armoured
Copper Cable 12Cx2.5sqmm Armoured (Control Cable)
Copper Cable 4Cx6 sqmm Armoured
B. HT Cables
Overhead ACSR Conductor
33 kv, 3CX185mmsq -Al (Transformer to HT Panel & Power Evacuation)

Multimode and Single mode Fiber cable as per design requirement

LT Power Cable will be 1.1 kV, Armoured, unearthed grade, double core/multi-core,
stranded Cu/Al conductor as mentioned, XLPE insulated with PVC outer sheath
made on PVC compound. All other details will be as Indian Standards .IEC 60189:
IS 694/ IS 1554/IS/IEC 69948

Earthed grade, XLPE, Armoured ,Aluminium, 3 core, PVC outer sheath, self
extinguishing type

Make

Unit

Essennar/Voltamp/Tesla or eq.

Nos.

Quantity

Swastik/Uttam

Nos.

ABB/Schneider/Their approved
System house

Nos.

Standard

Nos.

L&T/SKYTRON/Inaccess or Eq.

MW

11

D-Link/Spiktel

Mtrs

3300

eq.
eq.
eq.
eq.
eq.

Mtrs

2200
1100
1400
1750
1100

Standard
Havelles/Polycab/RPG or eq.

Mtrs
Mtrs

700
1400

Havelles/Polycab/RPG
Havelles/Polycab/RPG
Havelles/Polycab/RPG
Havelles/Polycab/RPG
Havelles/Polycab/RPG

or
or
or
or
or

EARTHING SYSTEM OF TOTAL PLANT including modules,


Laying of GI Flat 50x8 mm, GI Flat 25x3 mm, GI Pipe in the entire plant for
structure, all electrical equipments, switch yard and Lightening equipment earthing. Earth pits as per IS 3043. Providing Lightening arrestor poles,
Protection for the entire plant
spikes and air termination rods of suitable height along with cables upto earthing
points so as to cover the entire plant area.

Custom Made

MW

11

7
8

33 KV Four Pole structure


SDB - 415 volt, 50 cycles for LT Distribution System with 1
Incomer and 3 outgoing feeder of Three Phase and 3 outgoing
feeder of Single Phase

Custom Made
Custom Made

Set
Nos.

1
7

Nos.
MW

10
11

MW
LS
LS
LS

11
1
1
1

Raychem/3M

Nos.

Standard

LS
MW

1
11

9
10

11
(i)
(ii)
(iii)

Disc Insulator, Isolator, Pin insulator, LA, CT-PT, Meter


415 V LT SCB with 1 incomer from Auxiliary Transformer and 3 Nos. 3 Ph 415V
outgoing feeders and 3 Nos. single Phase 220 V outgoing feeders.

Plant Lighting System LED light 15Wp and cabling


2 Lights at Main gate and two at Inverter room
Safety Items (Any other item as required for proper safety of a FIRE BUCKETS-12 Nos, 4.5 kg CO2 FIRE EXTINGUISHERS-6 Nos, FOAM FIRE
power plant as per statutory requirement to be included)
EXTINGUISHERS -6 no.
Danger boards as per IS 2551 33kV
Danger boards as per IS 2551- 415V
First aid box as per IS
2 Nos. Shock treatment charts duly framed as per IS
33kV grade hand gloves as per IS
2 Nos. 12mm thick 900 mm x 1800 mm rubber mats conforming to latest IS
standards
ELECTRICAL ACCESSORIES :Control Terminal Clips on Type, Cable Glands Double crimping
Crimping Type Lugs
Armored cable end Termination Kits

U-Type, Ring Type, Pin Type for different cables


Cable termination of Armored cables including supply of double compression
brass cable glands with earth tags, crimping type tinned copper lugs,heat
shrinkable cable sealing kits and consumables for the following size of cables.
For 33kV,3C x 185 sq mm,Unearthed grade AL XLPE with heat shrinkable sealing
kits

(iv)
12

Conduits of different sizes


DC/AC Area Work

Complete Plant AC and DC work

Custom Made

Custom Made
Custom Made
Standard

Civil Works (Annexure -II)

SL. No
1
(i)
(ii)
(iii)
(iv)
(v)
(vi)
(vii)
2
3
(a)
(b)
4

5
Note:

Item
Foundations and complete Civil Works for :Main Transformers
Structure Foundation for LA and Isolator
VCB Panels
C&R Panel
Four Pole Structure
Auxiliary Transformer
Metering Cubical Foundation
Mod. Mounting Structures Foundation
Cable Trenches (Included In AC/DC Work)
For HT Cable
For LT Cable
Inverter Room CFL, Micro filter, Duct outlet for
hot air , switches, PVC conduit and necessary
wiring from auxiliary supply point for local
lighting etc

Unit
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
MW
Mtrs
Mtrs
Nos.

Four Pole and Transformer Yard Fencing


Nos.
1) No peripheral roads.
2) Only WBM roads upto inverter/control rooms.
3) Minimum Drainage work as required to prevent water logging.

nt water logging.

Quantity
7
7
7
7
1
1
1
11
1400
8800
4