Advance Data Sheet

BCM4706
Communications Processor with Network
Acceleration Hardware
GE N ER A L DE S CR I P TI O N

F E A T U RE S

The Broadcom BCM4706 processor is a


communications device targeted for wireless access
points and routers.

Advanced MIPS32 74K Core


- 32 KB I-cache, 32 KB D-cache
- BCM4706 CPU runs at 600 MHz/1200 DMIPs
On-chip SoC RAM provides low latency read/
write access to improve system performance
Advanced Gigabit Ethernet MAC
MII/RGMII/SGMII interface
Supports external GbE switch (such as
BCM53115/BCM53125)
Supports external 10/100 switch (such as
BCM5325E)
One USB 2.0 host port
16-bit/32-bit DDR2 300 MHz memory interface
Supports serial or parallel Flash
Dual PCI Express interface compliant with PCI
Express base specification revision 1.1
UART/MDIO/SPI/JTAG interface, up to 16 GPIOs
I8S audio/TDM voice interfaces
BCM4706 package: 23 mm 23 mm, 484-pin
PBGA

At the center of the device is a high-performance


600 MHz MIPS32 74K core with a 32 KB four-way
set associative instruction cache, a 32 KB four-way
set associative data cache, and a 64-entry translation
lookaside buffer (TLB). Enhanced CPU memory
subsystem architecture provides increased system
performance. The device uses state-of-the-art, low
power, and low leakage 65 nm LP technology.
The BCM4706 integrates several peripheral
interfaces including Gigabit Ethernet MACs, USB 2.0,
PCI Express, serial and parallel Flash, DDR memory,
and audio/voice TDM subsystem. Various common I/
O controllers are also integrated. These I/O
controllers include JTAG, UART, MDIO, GPIO, and SPI.

RGMII
or MII
2.5 Gbps

MIPS32 Core
(600 MHz)

DDR2
Memory Controller

2.5 Gbps

SerDes

EJTAG
I-Cache
32 KB

D-Cache
32 KB

SGMII/
SerDes

480 Mbps

SerDes

SerDes

USB Phy

PCle
1x1

PCle
1x1

USB 2.0
Host

GMAC

GMAC

Parser/FP

Parser/FP

DMA

DMA

CPU Local Bus


SoC-RAM
(512 KB)

System Bus

System Bus
TDM
Peripheral Interface

GPIO

Serial
Flash

Parallel
Flash
8b/16b

SPI

I2C

UART
/I2C

UART
I8S/TDM
2 VOIP Channels
or
8 Audio Channels

Figure 1: Functional Block Diagram


4706-DS00-R
5300 California Avenue Irvine, CA 92617 Phone: 949-926-5000 Fax: 949-926-5203
4/12/2011 DXKOG

June 02, 2010

Revision History
Revision

Date

Change Description

4706-DS00-R

06/02/10

Initial release

Broadcom Corporation
5300 California Avenue
Irvine, CA 92617
2010 by Broadcom Corporation
All rights reserved
Printed in the U.S.A.
Broadcom, the pulse logo, Connecting everything, and the Connecting everything logo are among the
trademarks of Broadcom Corporation and/or its affiliates in the United States, certain other countries and/
or the EU. Any other trademarks or trade names mentioned are the property of their respective owners.
This data sheet (including, without limitation, the Broadcom component(s) identified herein) is not designed,
intended, or certified for use in any military, nuclear, medical, mass transportation, aviation, navigations,
pollution control, hazardous substances management, or other high risk application. BROADCOM PROVIDES
THIS DATA SHEET "AS-IS", WITHOUT WARRANTY OF ANY KIND. BROADCOM DISCLAIMS ALL WARRANTIES,
EXPRESSED AND IMPLIED, INCLUDING, WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF
MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT.
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

Table of Contents

Table of Contents
Section 1: Functional Description ...................................................................................... 9
Overview.........................................................................................................................................................9
MIPS Core .......................................................................................................................................................9
Reset ...............................................................................................................................................................9
Crystal Oscillator and Clock Generator..........................................................................................................9
DDR2 SDRAM Interface ................................................................................................................................10
USB 2.0 Host Controllers ..............................................................................................................................10
PCI Express Interface ....................................................................................................................................10
Transaction Layer Interface ...................................................................................................................11
Data Link Layer.......................................................................................................................................11
Physical Layer.........................................................................................................................................12
Logical Subblock.....................................................................................................................................12
Scrambler/Descrambler.........................................................................................................................12
8B/10B Encoder/Decoder ......................................................................................................................12
Elastic FIFO.............................................................................................................................................12
Electrical Subblock .................................................................................................................................13
Configuration Space...............................................................................................................................13
10/100/1000 Ethernet MAC Controller .......................................................................................................13
Flash Interface ..............................................................................................................................................13
SPI/UART/GPIO Interface.............................................................................................................................14
I8S/TDM Interface ........................................................................................................................................14

Section 2: Hardware Signal Descriptions.......................................................................... 15


BCM4706 Pin Tables .....................................................................................................................................21
BCM4706 Ballmap ........................................................................................................................................27

Section 3: Electrical Characteristics.................................................................................. 28


Absolute Maximum Ratings .........................................................................................................................28
Recommended Operating Conditions and DC Characteristics....................................................................29
Core and I/O Power Sequencing Requirements ..........................................................................................30
DDR2 SDRAM Memory Interface DC Characteristics ..................................................................................31
USB Host Interface DC Characteristics .........................................................................................................31
PCIe DC Characteristics.................................................................................................................................33
1G SGMII/SerDes Port Signals......................................................................................................................33
Standard 3.3V Signals...................................................................................................................................34
Standard 2.5V Signals...................................................................................................................................34

BROADCOM
June 02, 2010 4706-DS00-R

Page 3
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

Table of Contents

XTAL Oscillator Interface..............................................................................................................................34

Section 4: Timing Characteristics ..................................................................................... 35


Reset and Clock Timing ................................................................................................................................35
Parallel Flash Timing.....................................................................................................................................36
Parallel Flash READ Timing.....................................................................................................................36
Parallel Flash WRITE Timing...................................................................................................................37
Serial Flash Timing (ST Micro-compatible Device) ......................................................................................38
DDR2 SDRAM AC Timing Characteristics .....................................................................................................39
USB Host Interface AC Timing Characteristics .............................................................................................40
PCIe Interface Timing ...................................................................................................................................41
PCIe_REFCLKP/N Timing ........................................................................................................................41
MII Interface Timing .....................................................................................................................................43
MII Input Timing.....................................................................................................................................43
MII Output Timing..................................................................................................................................44
RGMII Interface Timing ................................................................................................................................45
RGMII Output Timing (Normal Mode) ...................................................................................................45
RGMII Output Timing (Delayed Mode) ..................................................................................................46
RGMII Input Timing (Normal Mode) ......................................................................................................47
RGMII Input Timing (Delayed Mode) .....................................................................................................48
SGMII/SerDes Serial Interface......................................................................................................................49
Serial Interface Output Timing...............................................................................................................49
Serial Interface Input Timing..................................................................................................................50
I8S/TDM Audio/Video AC Specification ......................................................................................................51
JTAG Interface ..............................................................................................................................................52
MDC/MDIO Master Interface ......................................................................................................................53
SPI Master Interface .....................................................................................................................................54
Timing Parameters for CPHA=0 .............................................................................................................54
Timing Parameters for CPHA=1 .............................................................................................................55

Section 5: Thermal Specifications .................................................................................... 56


BCM4706.......................................................................................................................................................56
BCM4706 Thermal Specifications Without External Heatsink at 70C ..................................................56
BCM4706 Thermal Specifications with External Heatsink at 70C.........................................................57
BCM4706 Thermal Specifications Without External Heatsink at 85C ..................................................58
BCM4706 Thermal Specifications with External Heatsink at 85C.........................................................59

Section 6: Mechanical Information.................................................................................. 60


BCM4706.......................................................................................................................................................60

BROADCOM
June 02, 2010 4706-DS00-R

Page 4
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

Table of Contents

Section 7: Ordering Information ...................................................................................... 61

BROADCOM
June 02, 2010 4706-DS00-R

Page 5
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

List of Figures

List of Figures
Figure 1: Functional Block Diagram....................................................................................................................1
Figure 2: PCI Express Layer Model ...................................................................................................................11
Figure 3: BCM4706 BallmapTop View...........................................................................................................27
Figure 4: Power Supply Sequencing .................................................................................................................30
Figure 5: Reset and Clock Timing......................................................................................................................35
Figure 6: Parallel Flash READ Timing Diagram..................................................................................................36
Figure 7: Parallel Flash WRITE Timing Diagram ................................................................................................37
Figure 8: Serial Flash Timing Diagram ..............................................................................................................38
Figure 9: PCIe_REFCLKP/N Timing ....................................................................................................................41
Figure 10: PCIe[1:0]_RDP/N Timing..................................................................................................................41
Figure 11: PCIe[1:0]_TDP/N Timing..................................................................................................................42
Figure 12: MII Input Timing ..............................................................................................................................43
Figure 13: MII Output Timing ...........................................................................................................................44
Figure 14: RGMII Output Timing (Normal Mode).............................................................................................45
Figure 15: RGMII Output Timing (Delayed Mode)............................................................................................46
Figure 16: RGMII Input Timing (Normal Mode)................................................................................................47
Figure 17: RGMII Input Timing (Delayed Mode)...............................................................................................48
Figure 18: Serial Interface Output Timing ........................................................................................................49
Figure 19: Serial Interface Input Timing ...........................................................................................................50
Figure 20: IXS Transmitter Timing ....................................................................................................................51
Figure 21: IXS Receiver Timing .........................................................................................................................51
Figure 22: JTAG Interface .................................................................................................................................52
Figure 23: MDC/MDIO Master Interface..........................................................................................................53
Figure 24: SPI Master Interface: Timing Parameters for CPHA=0 ....................................................................54
Figure 25: SPI Master Interface: Timing Parameters for CPHA=1 ....................................................................55
Figure 26: BCM4706 Mechanical Information .................................................................................................60

BROADCOM
June 02, 2010 4706-DS00-R

Page 6
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

List of Tables

List of Tables
Table 1: Hardware Signals ................................................................................................................................15
Table 2: BCM4706 Sorted by Pin Location .......................................................................................................21
Table 3: BCM4706 Sorted by Signal Name .......................................................................................................24
Table 4: Absolute Maximum Ratings................................................................................................................28
Table 5: Recommended Operating Conditions ................................................................................................29
Table 6: Total Power and Supply Current.........................................................................................................29
Table 7: DC Characteristics for DDR2 SDRAM Interface...................................................................................31
Table 8: USB Host Interface DC Characteristics................................................................................................31
Table 9: USB 1.1 Electrical and Timing Parameters..........................................................................................32
Table 10: PCIe DC Characteristics.....................................................................................................................33
Table 11: 1G SGMII/SerDes Port Signals ..........................................................................................................33
Table 12: Standard 3.3V Signals .......................................................................................................................34
Table 13: Standard 2.5V Signals .......................................................................................................................34
Table 14: XTAL Oscillator Interface ..................................................................................................................34
Table 15: Reset and Clock Timing.....................................................................................................................35
Table 16: Parallel Flash READ Timing ...............................................................................................................36
Table 17: Parallel Flash WRITE Timing..............................................................................................................37
Table 18: Serial Flash Timing ............................................................................................................................38
Table 19: AC Characteristics for DDR SDRAM Interface ...................................................................................39
Table 20: USB 2.0 Host Interfaces Timing Parameters .....................................................................................40
Table 21: USB 1.1 Timing Parameters ..............................................................................................................40
Table 22: PCIe_REFCLKP/N Timing ...................................................................................................................41
Table 23: PCIe[1:0]_RDP/N Timing...................................................................................................................42
Table 24: PCIe[1:0]_TDP/N Timing ...................................................................................................................42
Table 25: MII Input Timing ...............................................................................................................................43
Table 26: MII Output Timing ............................................................................................................................44
Table 27: RGMII Output Timing (Normal Mode) ..............................................................................................45
Table 28: RGMII Output Timing (Delayed Mode).............................................................................................46
Table 29: RGMII Input Timing (Normal Mode) .................................................................................................47
Table 30: RGMII Input Timing (Delayed Mode)................................................................................................48
Table 31: Serial Interface Output Timing .........................................................................................................49
Table 32: Serial Interface Input Timing ............................................................................................................50
Table 33: IXS Receiver Timing...........................................................................................................................51
Table 34: JTAG Interface...................................................................................................................................52
Table 35: MDC/MDIO Master Interface ...........................................................................................................53

BROADCOM
June 02, 2010 4706-DS00-R

Page 7
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

List of Tables

Table 36: SPI Master Interface .........................................................................................................................54


Table 37: Timing Parameters for CPHA=1 ........................................................................................................55
Table 38: Package for 2s2p Board,
TA = 70C, P = 2.7W from Simulation ..............................................................................................56
Table 39: BCM4706 Thermal Specifications Without External Heatsink at 70C .............................................56
Table 40: Package with 30x30x25 mm External Heat Sink on 2s2p Board,
TA = 70C, P = 2.7W from Simulation ..............................................................................................57
Table 41: BCM4706 Thermal Specifications with 30x30x25 mm External Heatsink at 70C............................57
Table 42: Package for 2s2p Board,
TA = 85 C, P = 2.7 W from Simulation ............................................................................................58
Table 43: BCM4706 Thermal Specifications Without External Heatsink at 85C .............................................58
Table 44: Package with 30x30x25 mm External Heat Sink on 2s2p Board,
TA = 85C, P = 2.7W from Simulation ..............................................................................................59
Table 45: BCM4706 Thermal Specifications with 30x30x25 mm External Heatsink at 85C............................59
Table 46: Ordering Information .......................................................................................................................61

BROADCOM
June 02, 2010 4706-DS00-R

Page 8
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

Functional Description

Section 1: Functional Description


Overview
The Broadcom BCM4706 is a family of processors optimized for power and cost without compromising
performance. Integrating a high-performance 600 MHz MIPS32 74KTM core with a 32 KB four-way set
associative instruction cache, a 32 KB four-way set associative data cache, and a 64-entry TLB, the BCM4706
offers significant performance improvements in both transfer rates and CPU utilization.
Flexible support for a variety of system bus interfaces is provided including Gigabit Ethernet MACs, an audio/
voice TDM unit, a USB 2.0 host port, PCI Express (X1 lane), 16-bit/32-bit DDR2 300 MHz memory control, serial
Flash port, and 16-bit parallel Flash port. There are 16 GPIOs on the BCM4706 processor. All inputs can be used
to generate processor interrupts.

MIPS Core
The chip integrates an advanced 600 MHz MIPS32 74K core with a 32 KB four-way set associative I-cache and
a 32 KB four-way set associative D-Cache. The MIPS32 74K core has an integrated 32 32-bit single-cycle
multiply/accumulate block running at CPU core speed, providing additional signal or media processing
capabilities. The integrated MMU with a 64-entry TLB block is included, allowing support for common
multithreaded real-time operating systems (RTOS) such as the standard Linux distribution.

Reset
A power-on or hard reset is initiated by an active low reset pulse on the RESET_N Schmitt-triggered input pin.
The reset signal has a minimum required low pulse duration to guarantee that a sufficiently long reset is applied
to all internal circuits, including integrated PHYs (see Table 15: Reset and Clock Timing, on page 35). The
initialization process loads all pin configurable modes, resets all internal processes, and puts the device in the
idle state. During initialization, the clock source input signal must be active, and the 3.3V power supply to the
device must be stable.

Crystal Oscillator and Clock Generator


A typical BCM4706-based platform requires only a single crystal to clock the entire device. Several internal PLLs
are driven by the oscillator and generate the various clocks, including the clock for the 10/100/1000 MAC core
and the MIPS32 74K, DDR2 SDRAM, PCIe, UART, and USB 2.0 host controllers.

BROADCOM
June 02, 2010 4706-DS00-R

Page 9
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

DDR2 SDRAM Interface

DDR2 SDRAM Interface


The integrated DDR2 controller has on-chip serial termination resistors on the address, data and control
signals, except DDR clocks. The differential clock pair needs external serial termination resistors. Additionally,
VREF pin must be set to half of the DDR_OVDD_1P8 voltage. This can be accomplished by using two equal value
resistors to divide the DDR_OVDD_1P8 voltage.

USB 2.0 Host Controllers


The BCM4706 integrates a USB 2.0 host controller that supports high-speed USB 2.0 ports. It is also backward
compatible with full-speed and low-speed USB 1.1 devices. Each host port has a dedicated overcurrent input
to notify the OS or driver to take appropriate action. Individual port power control is also available.

PCI Express Interface


The PCI Express (PCIe) core on the BCM4706 is a high performance serial I/O interconnect that is protocol
compliant and electrically compatible with the PCI Express Base Specification v1.1. This core contains all the
necessary blocks, including logical and electrical functional subblocks, to perform PCIe functionality and
maintain high-speed links using existing PCI system configuration software implementations without
modification.
The PCIe core is organized in logical layers: Transaction Layer, Data Link Layer, and Physical Layer, as shown in
Figure 2. A configuration or link management block is provided for enumerating the PCIe configuration space
and supporting generation and reception of System Management Messages by communicating with PCIe
layers.
Each layer is partitioned into dedicated transmit and receive units that allow point-to-point communication
between the host and BCM4706 device. The transmit side processes outbound packets while the receive side
processes inbound packets. Packets are formed and generated in the Transaction and Data Link Layer for
transmission onto the high-speed links and onto the receiving device. A header is added at the beginning to
indicate the packet type and any other optional fields.

BROADCOM
June 02, 2010 4706-DS00-R

Page 10
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

PCI Express Interface

HW/SW Interface

HW/SW Interface

Transaction
Layer

Transaction
Layer

Data Link
Layer

Data Link
Layer

Physical Layer

Physical Layer

Logical Subblock

Logical Subblock

Electrical Subblock

Electrical Subblock

TX

TX

RX

RX

Figure 2: PCI Express Layer Model

Transaction Layer Interface


The PCIe core employs a packet-based protocol to transfer data between the host and BCM4706 device,
delivering new levels of performance and features. The upper layer of the PCIe is the Transaction Layer, which
is primarily responsible for assembly and disassembly of transaction layer packets (TLPs). TLP structure
contains header, data payload, and end-to-end CRC (ECRC) fields, which are used to communicate transactions,
such as read and write requests and other events.
A pipelined full split-transaction protocol is implemented in this layer to maximize efficient communication
between devices with credit-based flow control of TLP, which eliminates wasted link bandwidth due to retries.

Data Link Layer


The data link layer serves as an intermediate stage between the transaction layer and the physical layer. Its
primary responsibility is to provide a reliable, efficient mechanism for the exchange of TLPs between two
directly connected components on the link. Services provided by the data link layer include data exchange,
initialization, error detection and correction, and retry services.
Data link layer packets (DLLPs) are generated and consumed by the data link layer. DLLPs are the mechanism
used to transfer link management information between data link layers of the two directly connected
components on the link, including TLP acknowledgement, power management, and flow control.

BROADCOM
June 02, 2010 4706-DS00-R

Page 11
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

PCI Express Interface

Physical Layer
The physical layer of the PCIe provides a handshake mechanism between the data link layer and the high-speed
signaling used for Link data interchange. This layer is divided into the logical and electrical functional subblocks.
Both subblocks have dedicated transmit and receive units that allow for point-to-point communication
between the host and PCIe device. The transmit section prepares outgoing information passed from the data
link layer for transmission, and the receiver section identifies and prepares received information before passing
it to the data link layer. This process involves link initialization, configuration, scrambler, and data conversion
into a specific format.

Logical Subblock
The logical subblocks primary functions are to prepare outgoing data from the data link layer for transmission
and identify received data before passing it to the data link layer.

Scrambler/Descrambler
This PCIe PHY component generates a pseudo-random sequence for scrambling of data bytes and the idle
sequence. On the transmit side, scrambling is applied to characters prior to the 8b/10b encoding. On the
receive side, descrambling is applied to characters after 8b/10b decoding. Scrambling may be disabled in
polling and recovery for testing and debugging purposes.

8B/10B Encoder/Decoder
The PCIe core on the BCM4706 uses an 8b/10b encoder/decoder scheme to provide DC balancing, clock
synchronization and data recovery, and error detection. The transmission code is specified in ANSI X3.2301994, clause 11 and in IEEE 802.3z, 36.2.4.
Using this scheme, 8-bit data characters are treated as 3 bits and 5 bits mapped onto a 4-bit code group and a
6-bit code group, respectively. The control bit in conjunction with the data character is used to identify when
to encode one of the twelve Special Symbols included in the 8b/10b transmission code. These code groups are
concatenated to form a 10-bit Symbol, which is then transmitted serially. Special Symbols are used for link
management, frame TLPs, and DLLPs, allowing these packets to be quickly identified and easily distinguished.

Elastic FIFO
An elastic FIFO is implemented in the receiver side to compensate for the differences between the transmit
clock domain and the receive clock domain, with worst case clock frequency specified at 600 ppm tolerance.
As a result, the transmit and receive clocks can shift one clock every 1666 clocks. In addition, the FIFO
adaptively adjusts the elastic level based on the relative frequency difference of the write and read clock. This
technique reduces the elastic FIFO size and the average receiver latency by half.

BROADCOM
June 02, 2010 4706-DS00-R

Page 12
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

10/100/1000 Ethernet MAC Controller

Electrical Subblock
The high-speed signals utilize the common mode logic (CML) signaling interface with on-chip termination and
deemphasis for best in class signal integrity. A deemphasis technique is employed to reduce the effects of
intersymbol interference (ISI) due to the interconnect by optimizing voltage and timing margins for worst case
channel loss. This results in a maximally open eye at the detection point, thereby allowing the receiver to
receive data with an acceptable bit-error rate (BER).
To further minimize ISI, multiple bits of the same polarity that are output in succession are deemphasized.
Subsequent same bits are reduced by a factor of 3.5 dB in power. This amount is specified by PCIe to allow for
maximum interoperability while minimizing the complexity of controlling the deemphasis values. The highspeed interface requires AC coupling on the transmit side to eliminate the DC common mode voltage from the
receiver. The range of AC capacitance allowed is 75 nF to 200 nF.

Configuration Space
The PCIe function in the BCM4706 implements the configuration space as defined in the PCI Express Base
Specification v1.1.

10/100/1000 Ethernet MAC Controller


The BCM4706 integrates a high performance yet flexible Ethernet MAC controller. GMAC port 0 of the
BCM4706 supports the following interfaces through strap pin settings:
RGMII: 10/100/1000 Mbps mode
MII: 10/100 Mbps mode
The BCM4706 supports a second GMAC with SGMII interface in 10/100/1000 Mbps mode. These interfaces can
work with a wide variety of Ethernet PHYs and switches.
In RGMII mode, the bus signals operate at 2.5V, with the exception that the MDIO and MDC pins operate at
3.3V. All the Ethernet MAC controller output pins have built-in series termination so external termination
resistors are not required.

Flash Interface
An on-chip, 16-bit external bus interface (EBI) provides the following connectivity options:
16-bit NOR or NAND flash memory. BCM4706 supports up to 256 MB.
Serial Flash (ST-compatible four-pin SPI interface)
The BCM4706 has two Flash chip select pins so it can support up to two Flash devices in any of the
combinations in the following list:
One parallel Flash
One serial Flash

BROADCOM
June 02, 2010 4706-DS00-R

Page 13
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

SPI/UART/GPIO Interface

Two parallel Flash


Two serial Flash
One serial Flash + one parallel Flash (either the serial Flash or parallel Flash can be the boot device)
One serial Flash + NAND Flash (serial Flash must be the boot device to set up the on-chip NAND Flash
controller before it is accessed)

The BCM4706 has 16-bit parallel Flash data pins and supports either an 8-bit or 16-bit parallel Flash through
strap-pin settings when the parallel Flash is the boot device. However, byte-mode configuration should not be
used when 16-bit parallel Flash is used. When the BCM4706 is used in a configuration with two parallel Flash
devices, mixing of 8-bit and 16-bit parallel Flash memory is not supported.

SPI/UART/GPIO Interface
The BCM4706 supports one dedicated two-wire UART interface (UART_TX and UART_RX pins). It can support
one additional UART interface by sharing GPIO pins. The BCM4706 also supports one SPI master. The pin
sharing is enabled by software with the following configuration:
GPIO[3:0] and GPIO[9:8] can be configured as the SPI master interface.
GPIO[7:6] can be configured as the UART interface.
There are 16 3.3V GPIO pins on the BCM4706. These pins can be used to connect to various external devices.
Upon power-up and reset, these pins become tristated. Subsequently, they can be programmed to be either
input or output pins via the GPIO control register.

I8S/TDM Interface
The BCM4706 integrates a Voice/Audio TDM subsystem core that provides support for up to two full-duplex
voice channel conversations or up to eight audio channels for stereo or multichannel music/sound acquisition
or playback applications. The BCM4706 supports various flavors of TDM interface operations to work with
external A/D or D/A devices. The following list contains the possible channel combinations:
Audio/voice output only: one three-wire I8S/TDM interface
Audio/voice input only: one three-wire I8S/TDM interface
Full-duplex audio/voice: two three-wire I8S/TDM interfaces or one four-wire TDM interface

BROADCOM
June 02, 2010 4706-DS00-R

Page 14
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

Hardware Signal Descriptions

Section 2: Hardware Signal Descriptions


The section describes the BCM4706 hardware signals and uses the following conventions:
I = Input signal
O = Output signal
I/O = Bidirectional signal
IPD = Input Signal with internal pull-down
IPU = Input Signal with internal pull-up
Table 1: Hardware Signals
Pin Names

I/O

Pin Description

DDR SDRAM Interface


DDR_SDRAM_ADDR[14:0]
DDR_SDRAM_BA[2:0]
DDR_SDRAM_CAS
DDR_SDRAM_CKE
DDR_SDRAM_CS_N
DDR_SDRAM_ODT
DDR_SDRAM_RAS
DDR_SDRAM_REF

O
O
O
O
O
O
O
I

1.8V
1.8V
1.8V
1.8V
1.8V
1.8V
1.8V
0.9V

DDR_SDRAM_WE
DDR_SDRAM_ZQ

O
I/O

1.8V

DDR_SDRAM_CK0P/N
DDR_SDRAM_CK2P/N
DDR_SDRAM_DM[3:0]
DDR_SDRAM_DQSP[3:0]
DDR_SDRAM_DQSN[3:0]
DDR_SDRAM_DQ[31:0]

O
O
O
I/O
I/O
I/O

1.8V
1.8V
1.8V
1.8V
1.8V
1.8V

DDR2 address bus


DDR2 bank address
DDR2 column address select
DDR2 clock enable
DDR2 chip select
DDR2 on-die termination
DDR2 row address select
0.9V (DDR_OVDD_1P8 divided by two) DDR2 reference
voltage
DDR2 write enable
Output impedance calibration. This pin should be attached to
a 240 resister to VSS for impedance calibration.
DDR2 differential clock pair for byte lane 1 and 0
DDR2 differential clock pair for byte lane 3 and 2
DDR2 data mask
DDR2 differential pair data strobe for byte lane 3 to 0
DDR2 differential pair data strobe for byte lane 3 to 0
DDR2 data bus

BROADCOM
June 02, 2010 4706-DS00-R

Page 15
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

Hardware Signal Descriptions

Table 1: Hardware Signals (Cont.)


Pin Names

I/O

Pin Description

Parallel Flash Interface/Strap Pins


Note: Strap pin values are latched during reset, after reset the pin behaves as a Flash address pin.
FLASH_ADDR[26:0]
IPD/O 3.3V
When connecting to NAND Flash:
FLASH_ADDR0: NAND Flash CLE (command latch enable)
output.
FLASH_ADDR1: NAND Flash ALE (address latch enable)
output.
FLASH_ADDR2: NAND Flash WP# (write protect) output
(active low).
FLASH_ADDR21: NAND Flash R/B# (ready/not busy) input
with internal pullup.
FLASH_ADDR[4:20], [22:25]: Unused.
FLASH_ADDR6/
IPD/O 3.3V
MIPS EJTAG mode enable:
MIPS_EJTAG_MODE
0: General JTAG interface
1: MIPS EJTAG interface (connect to ICE)
FLASH_ADDR8/
IPD/O 3.3V
Ethernet interface voltage level select:
GMAC_VSEL
Set this pin low to configure port 0 GMAC interface to
operate in 2.5V RGMII.
Set this pin high for 3.3V MII.
FLASH_ADDR12/PCIe_DIS IPD/O 3.3V
PCIe port 1 disable:
0: PCIe port 1 is enabled.
1: PCIe port 1 is disabled for power saving.
FLASH_ADDR16/
IPD/O 3.3V
PCIe SerDes reference clock select:
PCIe_REFCLKSEL
0: Use internal PLL to generate 100 MHz clock.
1: Use the external 100 MHz differential clock source,
through PCIe_REFCLKP/N pins.
FLASH_ADDR17/
IPD/O 3.3V
Boot Flash type, depending on SFLASH_BOOT setting, this pin
BOOT_FLASH_TYPE
specifies the parallel Flash or serial Flash boot device type:
If (SFLASH_BOOT == 0):
0: 8-bit parallel Flash
1: 16-bit parallel Flash
If (SFLASH_BOOT == 1):
0: ST-compatible serial Flash
1: Atmel serial Flash
FLASH_ADDR18/
IPD/O 3.3V
Specifies using parallel Flash or serial Flash as the boot device:
SFLASH_BOOT
0: Boot device is a parallel Flash
1: Boot device is a serial Flash
FLASH_ADDR19/
IPD/O 3.3V
MIPS endian setting:
MIPS_ENDIAN
0: Little endian
1: Big endian

BROADCOM
June 02, 2010 4706-DS00-R

Page 16
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

Hardware Signal Descriptions

Table 1: Hardware Signals (Cont.)


Pin Names

I/O

FLASH_ADDR22/
TX_DELAY_MODE

IPD/O 3.3V

FLASH_ADDR23/
RX_DELAY_MODE

IPD/O 3.3V

FLASH_ADDR[25:24]/
GMAC_MODE

IPD/O 3.3V

FLASH_CS0_N

3.3V

FLASH_CS1_N

3.3V

FLASH_DATA[15:0]

I/O

3.3V

FLASH_OE_N

3.3V

FLASH_WE_N

3.3V

Pin Description
GMAC port 0 transmit interface 2 ns delay mode:
0: No delay
1: Enable 2 ns delay
GMAC port 0 receive interface 2 ns delay mode:
0: No delay
1: Enable 2 ns delay
GMAC port 0 interface mode:
2'b01: MII mode
2'b1x: RGMII mode
Chip select for the boot Flash (active low). Can be connected
to serial or parallel Flash
Chip select for second Flash (active low). Can be connected to
serial, parallel, or NAND Flash
Parallel/NAND Flash data bus. External pull downs are
required when unused.
Output enable (active low). NAND Flash RE# (read enable)
output (active low)
Write enable (active low). NAND Flash WE# (write enable)
output (active low)

Ethernet Interface (RGMII/MII)


Port 0
Note: RGMII10/100/1000 Mbps; MII10/100 Mbps only
GMAC_COL
IPD
2.5V/3.3V Collision detect
GMAC_CRS
IPD
2.5V/3.3V Carrier sense
GMAC_RXCLK
IPD/O 2.5V/3.3V Receive clock
GMAC_RXD[3:0]
IPD
2.5V/3.3V Receive data
GMAC_RXDV
IPD
2.5V/3.3V Receive data valid
GMAC_RXER
IPD
2.5V/3.3V Receive error
GMAC_TXCLK
IPD/O 2.5V/3.3V Transmit clock
GMAC_TXD[3:0]
O
2.5V/3.3V Transmit data
GMAC_TXEN
O
2.5V/3.3V Transmit enable
GMAC_TXER
O
2.5V/3.3V Transmit error
Port 1
Note: SGMII10/100/1000 Mbps
SGMII_TXDP
O
1.2V
SGMII SerDes transmit data
SGMII_TXDN
O
1.2V
SGMII SerDes transmit data
SGMII_RXDP
I
1.2V
SGMII SerDes receive data
SGMII_RXDN
I
1.2V
SGMII SerDes receive data

BROADCOM
June 02, 2010 4706-DS00-R

Page 17
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

Hardware Signal Descriptions

Table 1: Hardware Signals (Cont.)


Pin Names

I/O

Pin Description

GPIO/SPI/UART Interfaces (internal PU/PD of GPIOs is user-configurable through register setting)


GPIO0/SPI_SCLK
I/O
3.3V
GPIO bit 0 or SPI master clock output
GPIO1/SPI_SS0
I/O
3.3V
GPIO bit 1 or first SPI master select output
GPIO2/SPI_MOSI
I/O
3.3V
GPIO bit 2 or SPI master data output
GPIO3/SPI_MISO
I/O
3.3V
GPIO bit 3 or SPI master data input
GPIO4
I/O
3.3V
GPIO bit 4
GPIO5/
I/O
3.3V
GPIO bit 5
GPIO6/UART_RX2
I/O
3.3V
GPIO bit 6 or 2nd UART receive data input
GPIO7/UART_TX2
I/O
3.3V
GPIO bit 7 or 2nd UART transmit data output
GPIO8/SPI_SS1
I/O
3.3V
GPIO bit 8 or second SPI select
GPIO9/SPI_SS2
I/O
3.3V
GPIO bit 9 or third SPI select
GPIO10/FLASH_CS2_N
I/O
3.3V
GPIO bit 10 or additional chip select
GPIO11/FLASH_CS3_N
I/O
3.3V
GPIO bit 11 or additional chip select
GPIO[12:15]
I/O
3.3V
GPIO bits 12 to 15
JTAG Interface
JTCK
IPU
3.3V
JTAG clock
JTDI
IPU
3.3V
JTAG data input
JTDO
O
3.3V
JTAG data output
JTMS
IPU
3.3V
JTAG mode select
JTRST
IPU
3.3V
JTAG reset (active low)
MIIM Interface
MDC
O
3.3V
Management clock
MDIO
IPD/O 3.3V
Management data
PCIe Interface
PCIe0_RDN
I
1.2V
Negative leg of the differential pair receive serial data on PCIe
port 0
PCIe0_RDP
I
1.2V
Positive leg of the differential pair receive serial data on PCIe
port 0
PCIe0_TDN
O
1.2V
Negative leg of the differential pair transmit serial data on PCIe
port 0
PCIe0_TDP
O
1.2V
Positive leg of the differential pair transmit serial data on PCIe
port 0
PCIe0_RST_N
O
1.2V
PCIe port 0 reset (active low)
PCIe1_RDN
I
1.2V
Negative leg of the differential pair receive serial data on PCIe
port 1
PCIe1_RDP
I
1.2V
Positive leg of the differential pair receive serial data on PCIe
port 1
PCIe1_TDN
O
1.2V
Negative leg of the differential pair transmit serial data on PCIe
port 1

BROADCOM
June 02, 2010 4706-DS00-R

Page 18
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

Hardware Signal Descriptions

Table 1: Hardware Signals (Cont.)


Pin Names

I/O

Pin Description

PCIe1_TDP

1.2V

PCIe1_RST_N
PCIe_REFCLKOUTP/N
PCIe_REFCLKP/N

O
O
I

1.2V
1.2V
1.2V

Positive leg of the differential pair transmit serial data on PCIe


port 1
PCIe port 1 reset (active low)
100 MHz reference clock output differential pair
100 MHz reference clock input differential pair
This is used when FLASH_ADDR16/PCIe_REFCLKSEL pin is
enabled.

O
O
IPU

3.3V
3.3V
3.3V

Clock output for serial Flash


Data output signal driving serial Flash
Data input from serial Flash

IPU/O
IPU/O
IPU/O
IPU/O
IPU/O
IPU/O

3.3V
3.3V
3.3V
3.3V
3.3V
3.3V

TDM channel 0 bit clock


TDM channel 0 serial data input/output
TDM channel 0 word select
TDM channel 1 bit clock
TDM channel 1 serial data input/output
TDM channel 1 word select

IPU
O

3.3V
3.3V

UART receive data


UART transmit data

I/O
I/O

1.2V
1.2V

USB differential pair data


USB resistance reference. This pin should be connected to an
external 4.02 k resistor in parallel with a 100 pF capacitor to
ground.
USB over-current-detect input pin

Serial Flash Interface


SFlash_CLK
SFlash_SO
SFlash_SI
I8S/TDM Interface
TDM0_BITCLK
TDM0_SDIO
TDM0_WS
TDM1_BITCLK
TDM1_SDIO
TDM1_WS
UART Interface
UART_RX
UART_TX
USB Interface
USB_DATA_N/P
USB_RREF
USB_OCD
Miscellaneous Interface
RESET_N
XTALI
XTALO
OSC_XTAL_SEL

IPU

3.3V

IPU
I
O
IPD

3.3V
3.3V
3.3V
3.3V

NC

Chip reset, active low, Schmitt-triggered


25 MHz crystal/oscillator input
Crystal output
25 MHz oscillator/crystal input clock select, 0V: selects crystal,
3.3V: selects oscillator
No connect

BROADCOM
June 02, 2010 4706-DS00-R

Page 19
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

Hardware Signal Descriptions

Table 1: Hardware Signals (Cont.)


Pin Names

I/O

Power
CORE_DVDD_1P2
CORE_PLLAVDD_1P2
MISC1_PLLAVDD_1P2
MISC2_PLLAVDD_1P2
DDR_OVDD_1P8
INT_OVDD_33

1.2V
1.2V
1.2V
1.2V
1.8V
3.3V

GMAC_OVDD_25_33
PCIe_PLLVDD_1P2
PCIe_SDVDD_1P2
SGMII_PLLAVDD_1P2
SGMII_VDD_1P2
USB_DVDD_1P2
USB_PLLAVDD_1P2
USB_AVDD_2P5
USB_AVDD_3P3
XTAL_PLLAVDD_3P3
Ground
DVSS
PCIe_PLLVSS
PCIe_SDVSS
CORE_PLLAVSS
MISC1_PLLAVSS
MISC2_PLLAVSS
SGMII_PLLAVSS
SGMII_VSS
USB_AVSS

Pin Description

1.2V digital core power


1.2V core PLL analog power
1.2V miscellaneous PLL analog power
1.2V miscellaneous PLL analog power
1.8V DDR2 and 1.8V I/O power
3.3V interface I/O power, including Flash, I8S/TDM, GPIO,
MDC, UART, JTAG interfaces, and global clock/reset pins
2.5V/3.3V GMAC port 0 power supply, tied to 2.5V for RGMII, 3.3V for MII
1.2V
1.2V PCIe SerDes PLL analog power
1.2V
1.2V PCIe SerDes TX/RX analog power
1.2V
1.2V SGMII SerDes PLL power
1.2V
1.2V SGMII SerDes TX/RX analog power
1.2V
1.2V USB PHY PLL digital power
1.2V
1.2V USB PHY PLL analog power
2.5V
2.5V USB PHY analog power
3.3V
3.3V USB PHY analog power
3.3V
3.3V analog power for XTALI/O

0V
0V
0V
0V
0V
0V
0V
0V
0V

Ground
PCIe SerDes PLL analog ground
PCIe SerDes analog TX/RX ground
Core PLL analog ground
Miscellaneous PLL analog ground
Miscellaneous PLL analog ground
SGMII SerDes PLL ground
SGMII SerDes TX/RX ground
USB PHY ground

BROADCOM
June 02, 2010 4706-DS00-R

Page 20
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

BCM4706 Pin Tables

BCM4706 Pin Tables


Table 2: BCM4706 Sorted by Pin Location
Ball Signal

Ball Signal

Ball Signal

Ball Signal

A1

DDR_OVDD_1P8

B16

FLASH_ADDR5

D10

FLASH_DATA1

F1

DDR_SDRAM_DQ24

A2

DDR_SDRAM_DQ30

B17

DVSS

D11

DDR_SDRAM_DQ25

A3

DDR_SDRAM_DQ31

FLASH_WE_N

FLASH_ADDR23/
RX_DELAY_MODE

F2

B18

F3

DDR_SDRAM_DM3

A4

JTRST

B19

UART_TX

D12

FLASH_ADDR20

F4

DVSS

A5

JTMS

B20

MDIO

D13

FLASH_ADDR15

F5

INT_OVDD_33

A6

SFlash_SO

B21

GPIO13

D14

F6

DVSS

A7

FLASH_DATA15

B22

GPIO12

FLASH_ADDR12/
PCIe_DIS

F7

INT_OVDD_33

A8

FLASH_DATA11

C1

DDR_SDRAM_DQSP3

F8

DVSS

A9

FLASH_DATA7

C2

DDR_SDRAM_DQSN3

F9

INT_OVDD_33

A10

FLASH_DATA3

C3

DDR_OVDD_1P8

A11

FLASH_ADDR26

C4

DVSS

A12

FLASH_ADDR22/
TX_DELAY_MODE

C5

JTCK

C6

DVSS

FLASH_ADDR18/
SFLASH_BOOT

C7

FLASH_DATA14

C8

DVSS

C9

FLASH_DATA6

C10

DVSS

C11

FLASH_ADDR25/
GMAC_MODE

A13
A14

FLASH_ADDR14

A15

FLASH_ADDR10

A16

FLASH_ADDR6/
MIPS_EJTAG_MODE

A17

FLASH_ADDR2

A18

FLASH_OE_N

A19

UART_RX

A20

MDC

D15

FLASH_ADDR7

D16

FLASH_ADDR4

D17

NC

D18

INT_OVDD_33

D19

RESET_N

D20

USB_OCD

D21

GPIO9/SPI_SS2

D22

INT_OVDD_33

E1

DDR_SDRAM_DQ22

E2

DDR_SDRAM_DQ23

E3

DDR_SDRAM_DQ27

E4

NC

DVSS

E5

JTDI

FLASH_ADDR17/
BOOT_FLASH_TYPE

E6

SFlash_SI

E7

FLASH_DATA13

C14

DVSS

E8

FLASH_DATA8

C12
C13

A21

GPIO15

C15

FLASH_ADDR9

E9

FLASH_DATA5

A22

GPIO14

C16

DVSS

E10

FLASH_DATA0

E11

FLASH_ADDR24/
GMAC_MODE

B1

DDR_SDRAM_DQ26

C17

FLASH_ADDR1

B2

DVSS

C18

FLASH_CS0_N

B3

DVSS

C19

INT_OVDD_33

B4

DVSS

C20

DVSS

INT_OVDD_33

F16

DVSS

F17

INT_OVDD_33

F18

DVSS

F19

GPIO5

F20

GPIO8/SPI_SS1

F21

GPIO7/UART_TX2

F22

GPIO2/SPI_MOSI

G1

DDR_OVDD_1P8

G2

DVSS

G3

DDR_OVDD_1P8

G4

DVSS
DVSS
DVSS
DVSS

G8

DVSS

G9

CORE_DVDD_1P2

G10

DVSS
CORE_DVDD_1P2

GPIO10/FLASH_CS2_N

E14

FLASH_ADDR11

E15

FLASH_ADDR8/
GMAC_VSEL

DVSS

DVSS

F15

G7

C22
D2

F14

G6

FLASH_CS1_N
FLASH_DATA10

INT_OVDD_33

FLASH_ADDR16/
PCIe_REFCLKSEL

B6
B8

DVSS

F13

E13

GPIO11/FLASH_CS3_N
DDR_SDRAM_DQ28

F12

FLASH_ADDR19/
MIPS_ENDIAN

C21
D1

INT_OVDD_33

E12

DVSS
DVSS

DVSS

F11

G5

B5
B7

F10

B9

DVSS

D3

DDR_SDRAM_DQ29

E16

FLASH_ADDR3

G11

B10

FLASH_DATA2

D4

DVSS

E17

FLASH_ADDR0

G12

DVSS
CORE_DVDD_1P2

B11

DVSS

D5

JTDO

E18

DVSS

G13

B12

FLASH_ADDR21

D6

SFlash_CLK

E19

INT_OVDD_33

G14

DVSS
DVSS

B13

DVSS

D7

FLASH_DATA12

E20

OSC_XTAL_SEL

G15

B14

FLASH_ADDR13

D8

FLASH_DATA9

E21

DVSS

G16

DVSS

D9

FLASH_DATA4

E22

GPIO6/UART_RX2

G17

DVSS

B15

DVSS

BROADCOM
June 02, 2010 4706-DS00-R

Page 21
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

BCM4706 Pin Tables

Ball Signal

Ball Signal

Ball Signal

Ball Signal

G18

INT_OVDD_33

J17

DVSS

L16

DVSS

N15

DVSS

G19

GPIO4

J18

DVSS

L17

DVSS

N16

DVSS

G20

GPIO3/SPI_MISO

J19

NC

L18

PCIe_REFCLKN

N17

PCIe_SDVSS

G21

GPIO1/SPI_SS0

J20

TDM1_SDIO

L19

PCIe0_RDP

N18

PCIe_SDVSS

G22

GPIO0/SPI_SCLK

J21

TDM0_SDIO

L20

PCIe0_RDN

N19

PCIe0_TDP

H1

DDR_SDRAM_DQSP2

J22

TDM0_BITCLK

L21

PCIe_SDVDD_1P2

N20

PCIe0_TDN

H2

DDR_SDRAM_DQSN2

K1

DDR_SDRAM_DQ20

L22

PCIe1_RST_N

N21

PCIe_REFCLKOUTN

H3

DVSS

K2

DDR_SDRAM_DQ16

M1

DDR_SDRAM_DQ14

N22

PCIe_REFCLKOUTP

H4

DDR_SDRAM_DQ21

K3

DVSS

M2

DDR_SDRAM_DQ15

P1

DDR_SDRAM_DQ12

H5

DVSS

K4

DDR_SDRAM_DQ17

M3

DDR_OVDD_1P8

P2

DDR_SDRAM_DQ9

H6

DVSS

K5

DVSS

M4

DVSS

P3

DDR_OVDD_1P8

H7

DVSS

K6

DVSS

M5

DVSS

P4

DDR_SDRAM_DQ8

H8

DDR_OVDD_1P8

K7

DVSS

M6

DVSS

P5

DVSS

H9

DVSS

K8

DVSS

M7

DVSS

P6

DVSS

H10

CORE_DVDD_1P2

K9

DVSS

M8

DDR_OVDD_1P8

P7

DVSS

H11

DVSS

K10

DVSS

M9

DVSS

P8

DVSS

H12

CORE_DVDD_1P2

K11

DVSS

M10 DVSS

P9

DVSS

H13

DVSS

K12

DVSS

M11 DVSS

P10

DVSS

H14

CORE_DVDD_1P2

K13

DVSS

M12 DVSS

P11

DVSS

H15

DVSS

K14

CORE_DVDD_1P2

M13 DVSS

P12

DVSS

H16

DVSS

K15

DVSS

M14 CORE_DVDD_1P2

P13

DVSS

H17

DVSS

K16

PCIe_SDVSS

M15 DVSS

P14

CORE_DVDD_1P2

H18

NC

K17

DVSS

M16 DVSS

P15

DVSS

H19

NC

K18

PCIe_PLLVSS

M17 PCIe_SDVDD_1P2

P16

DVSS

H20

NC

K19

PCIe_SDVDD_1P2

M18 PCIe_REFCLKP

P17

DVSS

H21

TDM1_WS

K20

PCIe_SDVSS

M19 PCIe_SDVDD_1P2

P18

DVSS

H22

TDM0_WS

K21

PCIe0_RST_N

M20 PCIe_SDVSS

P19

PCIe_SDVDD_1P2

J1

DDR_SDRAM_CK2P

K22

TDM1_BITCLK

M21 PCIe1_RDP

P20

PCIe_PLLVDD_1P2

J2

DDR_SDRAM_CK2N

L1

DDR_SDRAM_DQ19

M22 PCIe1_RDN

P21

PCIe1_TDP

J3

DDR_OVDD_1P8

L2

DDR_SDRAM_DQ18

N1

DDR_SDRAM_DQSP1

P22

PCIe1_TDN

J4

DVSS

L3

DVSS

N2

DDR_SDRAM_DQSN1

R1

DDR_SDRAM_DQ11

J5

DVSS

L4

DDR_SDRAM_DM2

N3

DVSS

R2

DDR_SDRAM_DQ10

J6

DVSS

L5

DVSS

N4

DDR_SDRAM_DQ13

R3

DVSS

J7

CORE_DVDD_1P2

L6

DVSS

N5

DVSS

R4

DDR_SDRAM_DM1

J8

DVSS

L7

CORE_DVDD_1P2

N6

DVSS

R5

DVSS

J9

DVSS

L8

DVSS

N7

DVSS

R6

DVSS

J10

DVSS

L9

CORE_DVDD_1P2

N8

CORE_DVDD_1P2

R7

DVSS

J11

DVSS

L10

DVSS

N9

DVSS

R8

CORE_DVDD_1P2

J12

DVSS

L11

DVSS

N10

DVSS

R9

DVSS

J13

DVSS

L12

DVSS

N11

DVSS

R10

DDR_OVDD_1P8

J14

DVSS

L13

DVSS

N12

DVSS

R11

CORE_DVDD_1P2

J15

DVSS

L14

DVSS

N13

DVSS

R12

DVSS

J16

DVSS

L15

DVSS

N14

DVSS

R13

DVSS

BROADCOM
June 02, 2010 4706-DS00-R

Page 22
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

BCM4706 Pin Tables

Ball Signal

Ball Signal

Ball Signal

Ball Signal

R14

DVSS

U13

SGMII_PLLAVDD_1P2

W12 SGMII_PLLAVDD_1P2

AA11 XTAL_PLLAVDD_3P3

R15

DVSS

U14

SGMII_VDD_1P2

W13 SGMII_VDD_1P2

AA12 XTALO

R16

DVSS

U15

DVSS

W14 SGMII_VDD_1P2

AA13 SGMII_VDD_1P2

R17

DVSS

U16

DVSS

W15 SGMII_VDD_1P2

AA14 SGMII_TXDN

R18

DVSS

U17

GMAC_OVDD_25_33

W16 GMAC_TXD1

AA15 SGMII_VDD_1P2

R19

DVSS

U18

DVSS

W17 GMAC_TXCLK

AA16 SGMII_RXDP

R20

USB_AVDD_2P5

U19

USB_AVDD_3P3

W18 GMAC_COL

AA17 SGMII_VDD_1P2

R21

PCIe_SDVDD_1P2

U20

USB_AVSS

W19 GMAC_RXDV

AA18 GMAC_TXER

R22

PCIe_SDVSS

U21

NC

W20 MISC1_PLLAVSS

AA19 GMAC_RXD3

T1

DVSS

U22

USB_DATA_N

W21 MISC2_PLLAVDD_1P2

AA20 GMAC_RXD2

T2

DVSS

V1

DDR_OVDD_1P8

W22 NC

AA21 CORE_PLLAVDD_1P2

T3

DVSS

V2

DVSS

Y1

DDR_SDRAM_DQ7

AA22 NC

T4

DVSS

V3

DVSS

Y2

DDR_SDRAM_DQ3

AB1

DDR_SDRAM_CK0P

T5

DVSS

V4

DDR_SDRAM_CKE

Y3

DDR_SDRAM_DQ0

AB2

DDR_SDRAM_CK0N

T6

DVSS

V5

DDR_SDRAM_RAS

Y4

DDR_OVDD_1P8

AB3

DDR_SDRAM_ODT

T7

DVSS

V6

DDR_OVDD_1P8

Y5

DVSS

AB4

DDR_SDRAM_WE

T8

DVSS

V7

DVSS

Y6

DDR_SDRAM_BA1

AB5

DDR_SDRAM_BA0

T9

CORE_DVDD_1P2

V8

DVSS

Y7

DDR_SDRAM_ADDR0

AB6

DDR_SDRAM_ADDR2

T10

DVSS

V9

DVSS

Y8

DDR_SDRAM_ADDR4

AB7

DDR_SDRAM_ADDR5

T11

DVSS

V10

DDR_OVDD_1P8

Y9

DDR_SDRAM_ADDR6

AB8

DDR_SDRAM_ADDR8

T12

DVSS

V11

NC

Y10

DDR_SDRAM_ADDR10

AB9

DDR_SDRAM_ADDR11

T13

DVSS

V12

DVSS

Y11

NC

AB10 DDR_SDRAM_ADDR13

T14

CORE_DVDD_1P2

V13

NC

Y12

SGMII_PLLAVSS

AB11 SGMII_PLLAVSS

T15

DVSS

V14

SGMII_VSS

Y13

SGMII_VSS

AB12 XTALI

T16

DVSS

V15

DVSS

Y14

SGMII_VSS

AB13 SGMII_VSS

T17

DVSS

V16

DVSS

Y15

SGMII_VSS

AB14 SGMII_TXDP

T18

DVSS

V17

GMAC_OVDD_25_33

Y16

SGMII_VSS

AB15 SGMII_VSS

T19

USB_DVDD_1P2

V18

DVSS

Y17

GMAC_TXEN

AB16 SGMII_RXDN

T20

NC

V19

GMAC_CRS

Y18

GMAC_TXD3

AB17 SGMII_VSS

T21

USB_AVSS

V20

MISC2_PLLAVSS

Y19

GMAC_RXER

AB18 GMAC_TXD0

T22

USB_RREF

V21

USB_PLLAVDD_1P2

Y20

CORE_PLLAVSS

AB19 GMAC_TXD2

U1

DDR_SDRAM_DQSN0

V22

USB_DATA_P

Y21

MISC1_PLLAVDD_1P2

AB20 GMAC_RXCLK

U2

DDR_SDRAM_DQSP0

W1

DDR_SDRAM_DQ6

Y22

NC

AB21 GMAC_RXD1

U3

DVSS

W2

DDR_SDRAM_DQ5

AA1

DDR_SDRAM_DQ2

AB22 GMAC_RXD0

U4

DVSS

W3

DDR_SDRAM_DQ4

AA2

DDR_SDRAM_DQ1

U5

DVSS

W4

DVSS

AA3

DDR_SDRAM_DM0

U6

DVSS

W5

DDR_SDRAM_CAS

AA4

DDR_SDRAM_REF

U7

DVSS

W6

DDR_SDRAM_CS_N

AA5

DDR_SDRAM_BA2

U8

DVSS

W7

DDR_SDRAM_ADDR3

AA6

DVSS

U9

DVSS

W8

DDR_OVDD_1P8

AA7

DDR_SDRAM_ADDR1

U10

DVSS

W9

DDR_SDRAM_ADDR9

AA8

DVSS

U11

DVSS

W10 DDR_SDRAM_ADDR12

AA9

DDR_SDRAM_ADDR7

U12

DVSS

W11 DDR_SDRAM_ZQ

AA10 DDR_SDRAM_ADDR14

BROADCOM
June 02, 2010 4706-DS00-R

Page 23
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

BCM4706 Pin Tables

Table 3: BCM4706 Sorted by Signal Name


Signal

Ball

Signal

Ball

Signal

Ball

Signal

Ball

CORE_DVDD_1P2

G9

DDR_SDRAM_ADDR2

AB6

DDR_SDRAM_DQ27

E3

DVSS

C20

CORE_DVDD_1P2

G11

DDR_SDRAM_ADDR3

W7

DDR_SDRAM_DQ28

D1

DVSS

D2

CORE_DVDD_1P2

G13

DDR_SDRAM_ADDR4

Y8

DDR_SDRAM_DQ29

D3

DVSS

D4

CORE_DVDD_1P2

H10

DDR_SDRAM_ADDR5

AB7

DDR_SDRAM_DQ3

Y2

DVSS

E18

CORE_DVDD_1P2

H12

DDR_SDRAM_ADDR6

Y9

DDR_SDRAM_DQ30

A2

DVSS

E21

CORE_DVDD_1P2

H14

DDR_SDRAM_ADDR7

AA9

DDR_SDRAM_DQ31

A3

DVSS

F4

CORE_DVDD_1P2

J7

DDR_SDRAM_ADDR8

AB8

DDR_SDRAM_DQ4

W3

DVSS

F6

CORE_DVDD_1P2

K14

DDR_SDRAM_ADDR9

W9

DDR_SDRAM_DQ5

W2

DVSS

F8

CORE_DVDD_1P2

L7

DDR_SDRAM_BA0

AB5

DDR_SDRAM_DQ6

W1

DVSS

F10

CORE_DVDD_1P2

L9

DDR_SDRAM_BA1

Y6

DDR_SDRAM_DQ7

Y1

DVSS

F12

CORE_DVDD_1P2

M14

DDR_SDRAM_BA2

AA5

DDR_SDRAM_DQ8

P4

DVSS

F14

CORE_DVDD_1P2

N8

DDR_SDRAM_CAS

W5

DDR_SDRAM_DQ9

P2

DVSS

F16

CORE_DVDD_1P2

P14

DDR_SDRAM_CK0N

AB2

DDR_SDRAM_DQSN0

U1

DVSS

F18

CORE_DVDD_1P2

R8

DDR_SDRAM_CK0P

AB1

DDR_SDRAM_DQSN1

N2

DVSS

G2

CORE_DVDD_1P2

R11

DDR_SDRAM_CK2N

J2

DDR_SDRAM_DQSN2

H2

DVSS

G4

CORE_DVDD_1P2

T9

DDR_SDRAM_CK2P

J1

DDR_SDRAM_DQSN3

C2

DVSS

G5

CORE_DVDD_1P2

T14

DDR_SDRAM_CKE

V4

DDR_SDRAM_DQSP0

U2

DVSS

G6

CORE_PLLAVDD_1P2

AA21

DDR_SDRAM_CS_N

W6

DDR_SDRAM_DQSP1

N1

DVSS

G7

CORE_PLLAVSS

Y20

DDR_SDRAM_DM0

AA3

DDR_SDRAM_DQSP2

H1

DVSS

G8

DDR_OVDD_1P8

A1

DDR_SDRAM_DM1

R4

DDR_SDRAM_DQSP3

C1

DVSS

G10

DDR_OVDD_1P8

C3

DDR_SDRAM_DM2

L4

DDR_SDRAM_ODT

AB3

DVSS

G12

DDR_OVDD_1P8

G1

DDR_SDRAM_DM3

F3

DDR_SDRAM_RAS

V5

DVSS

G14

DDR_OVDD_1P8

G3

DDR_SDRAM_DQ0

Y3

DDR_SDRAM_REF

AA4

DVSS

G15

DDR_OVDD_1P8

H8

DDR_SDRAM_DQ1

AA2

DDR_SDRAM_WE

AB4

DVSS

G16

DDR_OVDD_1P8

J3

DDR_SDRAM_DQ10

R2

DDR_SDRAM_ZQ

W11

DVSS

G17

DDR_OVDD_1P8

M3

DDR_SDRAM_DQ11

R1

DVSS

B2

DVSS

H3

DDR_OVDD_1P8

M8

DDR_SDRAM_DQ12

P1

DVSS

B3

DVSS

H5

DDR_OVDD_1P8

P3

DDR_SDRAM_DQ13

N4

DVSS

B4

DVSS

H6

DDR_OVDD_1P8

R10

DDR_SDRAM_DQ14

M1

DVSS

B5

DVSS

H7

DDR_OVDD_1P8

V1

DDR_SDRAM_DQ15

M2

DVSS

B7

DVSS

H9

DDR_OVDD_1P8

V6

DDR_SDRAM_DQ16

K2

DVSS

B9

DVSS

H11

DDR_OVDD_1P8

V10

DDR_SDRAM_DQ17

K4

DVSS

B11

DVSS

H13

DDR_OVDD_1P8

W8

DDR_SDRAM_DQ18

L2

DVSS

B13

DVSS

H15

DDR_OVDD_1P8

Y4

DDR_SDRAM_DQ19

L1

DVSS

B15

DVSS

H16

DDR_SDRAM_ADDR0

Y7

DDR_SDRAM_DQ2

AA1

DVSS

B17

DVSS

H17

DDR_SDRAM_ADDR1

AA7

DDR_SDRAM_DQ20

K1

DVSS

C4

DVSS

J4

DDR_SDRAM_ADDR10 Y10

DDR_SDRAM_DQ21

H4

DVSS

C6

DVSS

J5

DDR_SDRAM_ADDR11 AB9

DDR_SDRAM_DQ22

E1

DVSS

C8

DVSS

J6

DDR_SDRAM_ADDR12 W10

DDR_SDRAM_DQ23

E2

DVSS

C10

DVSS

J8

DDR_SDRAM_ADDR13 AB10

DDR_SDRAM_DQ24

F1

DVSS

C12

DVSS

J9

DDR_SDRAM_ADDR14 AA10

DDR_SDRAM_DQ25

F2

DVSS

C14

DVSS

J10

DDR_SDRAM_DQ26

B1

DVSS

C16

DVSS

J11

BROADCOM
June 02, 2010 4706-DS00-R

Page 24
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

BCM4706 Pin Tables

Signal

Ball

Signal

Ball

Signal

Ball

Signal

Ball

DVSS

J12

DVSS

N5

DVSS

T7

FLASH_ADDR14

A14

DVSS

J13

DVSS

N6

DVSS

T8

FLASH_ADDR15

D13

DVSS

J14

DVSS

N7

DVSS

T10

J15

DVSS

N9

DVSS

T11

FLASH_ADDR16/
PCIe_REFCLKSEL

E13

DVSS
DVSS

J16

DVSS

N10

DVSS

T12

C13

DVSS

J17

DVSS

N11

DVSS

T13

FLASH_ADDR17/
BOOT_FLASH_TYPE

DVSS

J18

DVSS

N12

DVSS

T15

FLASH_ADDR18/
SFLASH_BOOT

A13

DVSS

K3

DVSS

N13

DVSS

T16

K5

DVSS

N14

DVSS

T17

FLASH_ADDR19/
MIPS_ENDIAN

E12

DVSS
DVSS

K6

DVSS

N15

DVSS

T18

FLASH_ADDR2

A17
D12

DVSS

K7

DVSS

N16

DVSS

U3

FLASH_ADDR20

DVSS

K8

DVSS

P5

DVSS

U4

FLASH_ADDR21

B12

FLASH_ADDR22/
TX_DELAY_MODE

A12

FLASH_ADDR23/
RX_DELAY_MODE

D11

FLASH_ADDR24/
GMAC_MODE

E11
C11

DVSS

K9

DVSS

P6

DVSS

U5

DVSS

K10

DVSS

P7

DVSS

U6

DVSS

K11

DVSS

P8

DVSS

U7

DVSS

K12

DVSS

P9

DVSS

U8

DVSS

K13

DVSS

P10

DVSS

U9

DVSS

K15

DVSS

P11

DVSS

U10

DVSS

K17

DVSS

P12

DVSS

U11

FLASH_ADDR25/
GMAC_MODE

DVSS

L3

DVSS

P13

DVSS

U12

FLASH_ADDR26

A11

DVSS

L5

DVSS

P15

DVSS

U15

FLASH_ADDR3

E16
D16

DVSS

L6

DVSS

P16

DVSS

U16

FLASH_ADDR4

DVSS

L8

DVSS

P17

DVSS

U18

FLASH_ADDR5

B16

FLASH_ADDR6/
MIPS_EJTAG_MODE

A16

FLASH_ADDR7

D15
E15

DVSS

L10

DVSS

P18

DVSS

V2

DVSS

L11

DVSS

R3

DVSS

V3

DVSS

L12

DVSS

R5

DVSS

V7

DVSS

L13

DVSS

R6

DVSS

V8

FLASH_ADDR8/
GMAC_VSEL

DVSS

L14

DVSS

R7

DVSS

V9

FLASH_ADDR9

C15

DVSS

L15

DVSS

R9

DVSS

V12

FLASH_CS0_N

C18

DVSS

L16

DVSS

R12

DVSS

V15

FLASH_CS1_N

B6

DVSS

L17

DVSS

R13

DVSS

V16

FLASH_DATA0

E10

DVSS

M4

DVSS

R14

DVSS

V18

FLASH_DATA1

D10

DVSS

M5

DVSS

R15

DVSS

W4

FLASH_DATA10

B8

DVSS

M6

DVSS

R16

DVSS

Y5

FLASH_DATA11

A8

DVSS

M7

DVSS

R17

DVSS

AA6

FLASH_DATA12

D7

DVSS

M9

DVSS

R18

DVSS

AA8

FLASH_DATA13

E7

DVSS

M10

DVSS

R19

FLASH_ADDR0

E17

FLASH_DATA14

C7

DVSS

M11

DVSS

T1

FLASH_ADDR1

C17

FLASH_DATA15

A7

DVSS

M12

DVSS

T2

FLASH_ADDR10

A15

FLASH_DATA2

B10

DVSS

M13

DVSS

T3

FLASH_ADDR11

E14

FLASH_DATA3

A10

DVSS

M15

DVSS

T4

D14

FLASH_DATA4

D9

DVSS

M16

DVSS

T5

FLASH_ADDR12/
PCIe_DIS

DVSS

T6

B14

E9

N3

FLASH_ADDR13

FLASH_DATA5

DVSS

BROADCOM
June 02, 2010 4706-DS00-R

Page 25
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

BCM4706 Pin Tables

Signal

Ball

Signal

Ball

Signal

Ball

Signal

Ball

FLASH_DATA6

C9

INT_OVDD_33

E19

PCIe_SDVDD_1P2

M17

SGMII_VSS

Y16

FLASH_DATA7

A9

INT_OVDD_33

F5

PCIe_SDVDD_1P2

M19

SGMII_VSS

AB13

FLASH_DATA8

E8

INT_OVDD_33

F7

PCIe_SDVDD_1P2

P19

SGMII_VSS

AB15

FLASH_DATA9

D8

INT_OVDD_33

F9

PCIe_SDVDD_1P2

R21

SGMII_VSS

AB17

FLASH_OE_N

A18

INT_OVDD_33

F11

PCIe_SDVSS

K16

TDM0_BITCLK

J22

FLASH_WE_N

B18

INT_OVDD_33

F13

PCIe_SDVSS

K20

TDM0_SDIO

J21

GMAC_COL

W18

INT_OVDD_33

F15

PCIe_SDVSS

M20

TDM0_WS

H22

GMAC_CRS

V19

INT_OVDD_33

F17

PCIe_SDVSS

N17

TDM1_BITCLK

K22

GMAC_OVDD_25_33

U17

INT_OVDD_33

G18

PCIe_SDVSS

N18

TDM1_SDIO

J20

GMAC_OVDD_25_33

V17

JTCK

C5

PCIe_SDVSS

R22

TDM1_WS

H21

GMAC_RXCLK

AB20

JTDI

E5

PCIe0_RDN

L20

UART_RX

A19

GMAC_RXD0

AB22

JTDO

D5

PCIe0_RDP

L19

UART_TX

B19

GMAC_RXD1

AB21

JTMS

A5

PCIe0_RST_N

K21

USB_AVDD_2P5

R20

GMAC_RXD2

AA20

JTRST

A4

PCIe0_TDN

N20

USB_AVDD_3P3

U19

GMAC_RXD3

AA19

MDC

A20

PCIe0_TDP

N19

USB_AVSS

T21

GMAC_RXDV

W19

MDIO

B20

PCIe1_RDN

M22

USB_AVSS

U20

GMAC_RXER

Y19

MISC1_PLLAVDD_1P2

Y21

PCIe1_RDP

M21

USB_DATA_N

U22

GMAC_TXCLK

W17

MISC1_PLLAVSS

W20

PCIe1_RST_N

L22

USB_DATA_P

V22

GMAC_TXD0

AB18

MISC2_PLLAVDD_1P2

W21

PCIe1_TDN

P22

USB_DVDD_1P2

T19

GMAC_TXD1

W16

MISC2_PLLAVSS

V20

PCIe1_TDP

P21

USB_OCD

D20

GMAC_TXD2

AB19

NC

D17

RESET_N

D19

USB_PLLAVDD_1P2

V21

GMAC_TXD3

Y18

NC

E4

SFlash_CLK

D6

USB_RREF

T22

GMAC_TXEN

Y17

NC

H18

SFlash_SI

E6

XTAL_PLLAVDD_3P3

AA11

GMAC_TXER

AA18

NC

H19

SFlash_SO

A6

XTALI

AB12

GPIO0/SPI_SCLK

G22

NC

H20

SGMII_PLLAVDD_1P2

U13

XTALO

AA12

GPIO1/SPI_SS0

G21

NC

J19

SGMII_PLLAVDD_1P2

W12

GPIO10/FLASH_CS2_N C22

NC

T20

SGMII_PLLAVSS

Y12

GPIO11/FLASH_CS3_N C21

NC

U21

SGMII_PLLAVSS

AB11

GPIO12

B22

NC

V11

SGMII_RXDN

AB16

GPIO13

B21

NC

V13

SGMII_RXDP

AA16

GPIO14

A22

NC

W22

SGMII_TXDN

AA14

GPIO15

A21

NC

Y11

SGMII_TXDP

AB14

GPIO2/SPI_MOSI

F22

NC

Y22

SGMII_VDD_1P2

U14

GPIO3/SPI_MISO

G20

NC

AA22

SGMII_VDD_1P2

W13

GPIO4

G19

OSC_XTAL_SEL

E20

SGMII_VDD_1P2

W14

GPIO5

F19

PCIe_PLLVDD_1P2

P20

SGMII_VDD_1P2

W15

GPIO6/UART_RX2

E22

PCIe_PLLVSS

K18

SGMII_VDD_1P2

AA13

GPIO7/UART_TX2

F21

PCIe_REFCLKN

L18

SGMII_VDD_1P2

AA15

GPIO8/SPI_SS1

F20

PCIe_REFCLKOUTN

N21

SGMII_VDD_1P2

AA17

GPIO9/SPI_SS2

D21

PCIe_REFCLKOUTP

N22

SGMII_VSS

V14

INT_OVDD_33

C19

PCIe_REFCLKP

M18

SGMII_VSS

Y13

INT_OVDD_33

D18

PCIe_SDVDD_1P2

K19

SGMII_VSS

Y14

INT_OVDD_33

D22

PCIe_SDVDD_1P2

L21

SGMII_VSS

Y15

BROADCOM
June 02, 2010 4706-DS00-R

Page 26
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

BCM4706 Ballmap

BCM4706 Ballmap
4

DDR_OVD DDR_SDR DDR_SDR


D_1P8
AM_DQ30 AM_DQ31

JTRST

JTMS

SFlash_SO

DDR_SDR
AM_DQ26

DVSS

DVSS

FLASH_CS
1_N

DVSS

DVSS

DVSS

DDR_SDR DDR_SDR
DDR_OVD
AM_DQSP AM_DQSN
D_1P8
3
3

DVSS

JTCK

DDR_SDR
AM_DQ28

DVSS

JTDO

DDR_SDR DDR_SDR DDR_SDR


AM_DQ22 AM_DQ23 AM_DQ27

NC

JTDI

DDR_SDR DDR_SDR DDR_SDR


AM_DQ24 AM_DQ25 AM_DM3

DVSS

INT_OVDD
_33

DVSS

INT_OVDD
_33

DVSS

DVSS

G
H

DVSS

DDR_SDR
AM_DQ29

DDR_OVD
DDR_OVD
DVSS
DVSS
D_1P8
D_1P8
DDR_SDR DDR_SDR
DDR_SDR
DVSS
AM_DQSP AM_DQSN
AM_DQ21
2
2

4/12/2011 DXKOG

DDR_SDR DDR_SDR DDR_OVD


AM_CK2P AM_CK2N
D_1P8

DDR_SDR DDR_SDR
AM_DQ20 AM_DQ16

DDR_SDR DDR_SDR
AM_DQ19 AM_DQ18

DDR_SDR DDR_SDR DDR_OVD


AM_DQ14 AM_DQ15
D_1P8

DDR_SDR DDR_SDR
AM_DQSP AM_DQSN
1
1

DVSS

DVSS

DVSS

DVSS

10

11

FLASH_DA
TA14

FLASH_DA
TA10

DVSS

DVSS

FLASH_DA
TA6

FLASH_DA
TA2

DVSS

DVSS
FLASH_AD
DR25/GMA
C_MODE

DVSS

INT_OVDD
_33

DVSS

DVSS

DVSS

DVSS

DDR_OVD
D_1P8

DVSS

CORE_DV
DD_1P2

DVSS

DVSS

INT_OVDD
_33

CORE_DV
DD_1P2

DVSS

DVSS

CORE_DV
DD_1P2

DVSS

DVSS

GPIO7/
GPIO8/SPI
GPIO2/SPI
UART_TX2
_SS1
_MOSI
GPIO3/SPI GPIO1/SPI GPIO0/SPI
_MISO
_SS0
_SCLK

DVSS

DVSS

DVSS

DVSS

DVSS

PCIe_REF
CLKN

DVSS

DVSS

DVSS

DVSS

CORE_DV
DD_1P2

DVSS

DVSS

PCIe_SDV PCIe_REF PCIe_SDV PCIe_SDV PCIe1_RD PCIe1_RD


DD_1P2
CLKP
DD_1P2
SS
P
N

DVSS

DVSS

DVSS

DVSS

DVSS

DVSS

DVSS

DVSS

PCIe_SDV PCIe_SDV
SS
SS

DVSS

DVSS

DVSS

DVSS

DVSS

CORE_DV
DD_1P2

DVSS

DVSS

DVSS

DVSS

DVSS

DVSS

DVSS

DVSS

DVSS

DVSS

DVSS

DVSS

USB_AVD
D_2P5

DVSS

CORE_DV
DD_1P2

DVSS

USB_DVD
D_1P2

NC

DVSS

USB_AVD
USB_AVSS
D_3P3

DVSS

GMAC_CR MISC2_PL USB_PLLA USB_DATA


S
LAVSS
VDD_1P2
_P

DVSS

DVSS

DDR_SDR DDR_SDR
AM_DQ11 AM_DQ10

DDR_SDR
AM_DM1

DVSS

DVSS

DVSS

CORE_DV
DD_1P2

DVSS

DVSS

CORE_DV
DD_1P2

DDR_OVD CORE_DV
D_1P8
DD_1P2
DVSS

DVSS

DVSS

DVSS

DDR_OVD
D_1P8

DDR_SDR
DDR_OVD
AM_ADDR
D_1P8
9
DDR_SDR DDR_SDR
AM_ADDR AM_ADDR
4
6
DDR_SDR
DVSS
AM_ADDR
7
DDR_SDR DDR_SDR
AM_ADDR AM_ADDR
11
8

DDR_SDR
AM_ADDR
12
DDR_SDR
AM_ADDR
10
DDR_SDR
AM_ADDR
14
DDR_SDR
AM_ADDR
13

DVSS

DVSS

DVSS

DVSS

DVSS

DVSS

GMAC_OV
DD_25_33

DVSS

GMAC_OV
DD_25_33

DVSS

TDM1_WS TDM0_WS

DVSS

DVSS

DVSS

NC

TDM1_SDI TDM0_SDI TDM0_BIT


O
O
CLK

DVSS

DVSS

AB

GPIO5

DVSS

DDR_SDR DDR_SDR DDR_OVD DDR_SDR


AM_DQ12
AM_DQ9
D_1P8
AM_DQ8

AA

DVSS

DVSS

INT_OVDD
_33

DVSS

CORE_DV
DD_1P2

DVSS

DVSS

DVSS

DVSS

INT_OVDD
_33

GPIO6/
UART_RX2

PCIe_PLLV PCIe_SDV PCIe_SDV PCIe0_RS


SS
T_N
SS
DD_1P2

DVSS

DVSS

DVSS

DVSS

DVSS

DVSS

DDR_SDR
DDR_SDR DDR_SDR
AM_ADDR
DVSS
AM_CAS AM_CS_N
3
DDR_SDR
DDR_SDR DDR_SDR DDR_SDR DDR_OVD
DDR_SDR
DVSS
AM_ADDR
AM_DQ7
AM_DQ3
AM_DQ0
D_1P8
AM_BA1
0
DDR_SDR
DDR_SDR DDR_SDR DDR_SDR DDR_SDR DDR_SDR
DVSS
AM_ADDR
AM_DQ2
AM_DQ1
AM_DM0
AM_REF
AM_BA2
1
DDR_SDR DDR_SDR
DDR_SDR DDR_SDR DDR_SDR DDR_SDR DDR_SDR
AM_ADDR AM_ADDR
AM_CK0P AM_CK0N AM_ODT
AM_WE
AM_BA0
5
2

GPIO9/SPI INT_OVDD
_SS2
_33

PCIe_SDV
SS

DDR_SDR
AM_DQ13

DVSS

USB_OCD

DVSS

DVSS

DVSS

DVSS

DVSS

DDR_OVD
D_1P8

DDR_SDR DDR_SDR DDR_SDR


AM_DQ6
AM_DQ5
AM_DQ4

GPIO12

GPIO11/FL GPIO10/FL
ASH_CS3_ ASH_CS2_
N
N

CORE_DV
DD_1P2

DVSS

GPIO13

MDIO

DVSS

DVSS

DVSS

22
GPIO14

INT_OVDD OSC_XTAL
_33
_SEL

NC

DVSS

21
GPIO15

DVSS

NC

DVSS

20
MDC

FLASH_AD
FLASH_AD FLASH_AD
DR8/GMAC
DR3
DR0
_VSEL

DVSS

DVSS

DVSS

INT_OVDD
RESET_N
_33

DVSS

DVSS

DVSS

NC

DVSS

DVSS

DVSS

FLASH_AD FLASH_CS INT_OVDD


DR1
0_N
_33

DVSS

CORE_DV
DD_1P2

DVSS

FLASH_
ADDR11

UART_TX

DVSS

DVSS

DDR_SDR DDR_SDR DDR_OVD


AM_CKE
AM_RAS
D_1P8

FLASH_AD
FLASH_AD FLASH_AD
DR12/PCIe
DR7
DR4
_DIS

FLASH_W
E_N

GPIO4

CORE_DV
DD_1P2

DVSS

DVSS

DVSS

INT_OVDD
_33

DVSS

DVSS

FLASH_AD
DR9

FLASH_AD
DR5

DVSS

DVSS

DVSS

DVSS

DVSS

DVSS

DDR_SDR
AM_DM2

DDR_OVD
D_1P8

DVSS

FLASH_AD
DR13

DVSS

DVSS

DVSS
FLASH_AD
DR17/BOO
T_FLASH_
TYPE

DVSS

DVSS

DVSS

FLASH_AD
DR21

CORE_DV
DD_1P2

DVSS

DVSS

19

CORE_DV
DD_1P2

DVSS

DVSS

18

DVSS

DVSS

DVSS

17

CORE_DV
DD_1P2

DVSS

DVSS

16

CORE_DV
DD_1P2

DVSS

DDR_SDR DDR_SDR
AM_DQSN AM_DQSP
0
0

15

INT_OVDD
_33

DVSS

14

DVSS

DVSS

DVSS

13

FLASH_AD
SFlash_CL FLASH_DA FLASH_DA FLASH_DA FLASH_DA DR23/RX_ FLASH_AD FLASH_AD
DR20
DR15
K
TA12
TA9
TA4
TA1
DELAY_M
ODE
FLASH_AD
FLASH_AD FLASH_AD
DR16/PCIe
FLASH_DA FLASH_DA FLASH_DA FLASH_DA
DR24/GMA DR19/MIPS
SFlash_SI
_REFCLKS
TA13
TA8
TA5
TA0
C_MODE
_ENDIAN
EL

DDR_SDR
AM_DQ17

DVSS

12

FLASH_AD FLASH_AD
FLASH_AD
FLASH_DA FLASH_DA FLASH_DA FLASH_DA FLASH_AD DR22/TX_ DR18/SFL FLASH_AD FLASH_AD DR6/MIPS_ FLASH_AD FLASH_OE
UART_RX
TA15
TA11
TA7
TA3
DR26
DELAY_M ASH_BOO
DR14
DR10
EJTAG_M
DR2
_N
ODE
T
ODE

NC

TDM1_BIT
CLK

PCIe0_RD PCIe0_RD PCIe_SDV PCIe1_RS


P
N
DD_1P2
T_N

PCIe0_TD
P

PCIe0_TD
N

PCIe_REF
CLKOUTN

PCIe_REF
CLKOUTP

PCIe_SDV PCIe_PLLV PCIe1_TD


DD_1P2
DD_1P2
P

PCIe1_TD
N

PCIe_SDV PCIe_SDV
DD_1P2
SS
USB_AVSS

USB_RRE
F

NC

USB_DATA
_N

DVSS

SGMII_PLL SGMII_VD
AVDD_1P2
D_1P2

DVSS

SGMII_VS
S

DVSS

DDR_SDR SGMII_PLL SGMII_VD


AM_ZQ
AVDD_1P2
D_1P2

SGMII_VD
D_1P2

SGMII_VD
D_1P2

SGMII_PLL SGMII_VS
AVSS
S

SGMII_VS
S

SGMII_VS
S

XTALO

SGMII_VD
D_1P2

SGMII_TX
DN

SGMII_VD
D_1P2

SGMII_RX
DP

SGMII_VD
D_1P2

GMAC_TX GMAC_RX GMAC_RX CORE_PLL


ER
D3
D2
AVDD_1P2

XTALI

SGMII_VS
S

SGMII_TX
DP

SGMII_VS
S

SGMII_RX
DN

SGMII_VS
S

GMAC_TX GMAC_TX GMAC_RX GMAC_RX GMAC_RX


D0
D2
CLK
D1
D0

DVSS

NC

NC
XTAL_PLL
AVDD_3P3
SGMII_PLL
AVSS

NC

DVSS

MISC2_PL
GMAC_TX GMAC_TX GMAC_CO GMAC_RX MISC1_PL
LAVDD_1P
D1
CLK
L
DV
LAVSS
2
MISC1_PL
SGMII_VS GMAC_TX GMAC_TX GMAC_RX CORE_PLL
LAVDD_1P
S
EN
D3
ER
AVSS
2

NC

NC

NC

Figure 3: BCM4706 BallmapTop View

BROADCOM

June 02, 2010 4706-DS00-R

Page 27

BCM4706 Advance Data Sheet

Electrical Characteristics

Section 3: Electrical Characteristics


Absolute Maximum Ratings
Table 4: Absolute Maximum Ratingsa
Parameter

Symbol

Min

Max

Units

3.3V Supply Voltage

INT_OVDD_33, GMAC_OVDD_25_33,
USB_AVDD_3P3, XTAL_PLLAVDD_3P3
GMAC_OVDD_25_33, USB_AVDD_2P5
CORE_DVDD_1P2, CORE_PLLAVDD_1P2,
MISC1_PLLAVDD_1P2, MISC2_PLLAVDD_1P2,
PCIe_PLLVDD_1P2, PCIe_SDVDD_1P2,
SGMII_PLLAVDD_1P2, SGMII_VDD_1P2,
USB_DVDD_1P2, USB_PLLAVDD_1P2
DDR_OVDD_1P8
TJ_MAX

0.5

+3.63

0.5
0.5

+2.75
+1.32

V
V

0.5

+1.98
+125

V
oC

TA

+70

oC

TA

40

+85

oC

TSTG

40

+85
+125
60

%
o
C
%

2.5V Supply Voltage


1.2V Supply Voltage

1.8V Supply Voltage


Maximum Junction
Temperature
Commercial Ambient
Temperature (Operating)
Industrial Ambient
Temperature (Operating)
Operating Humidity
Storage Temperature
Storage Humidity

a. These specifications indicate levels where permanent damage to the device may occur. Functional operation
is not guaranteed under these conditions. Operation at maximum conditions for extended periods may
adversely affect long-term reliability of the device.

BROADCOM
June 02, 2010 4706-DS00-R

Page 28
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

Recommended Operating Conditions and DC Characteristics

Recommended Operating Conditions and DC Characteristics


Table 5: Recommended Operating Conditions
Symbol

Nominal

Limits

Units

CORE_DVDD_1P2
1.2V
5%
V
CORE_PLLAVDD_1P2
1.2V
5%
V
MISC1_PLLAVDD_1P2
1.2V
5%
V
MISC2_PLLAVDD_1P2
1.2V
5%
V
DDR_OVDD_1P8
1.8V
0.1
V
INT_OVDD_33
3.3V
5%
V
GMAC_OVDD_25_33
2.5V/3.3V
5%
V
PCIe_PLLVDD_1P2
1.2V
5%
V
PCIe_SDVDD_1P2
1.2V
5%
V
SGMII_PLLAVDD_1P2
1.2V
5%
V
SGMII_VDD_1P2
1.2V
5%
V
USB_DVDD_1P2
1.2V
5%
V
USB_PLLAVDD_1P2
1.2V
5%
V
USB_AVDD_2P5
2.5V
5%
V
USB_AVDD_3P3
3.3V
5%
V
XTAL_PLLAVDD_3P3
3.3V
5%
V
Note: See the BCM4706 Hardware Design Guide on docSAFE for more information on power supplies
decoupling.

Table 6: Total Power and Supply Current


Supply Voltage

BCM4706 Typical Value

Units

3.3V
2.5V
1.8V
1.2V

75
105
840
1670

mW
mW
mW
mW

Note: These power consumption numbers were derived under nominal conditions. For example, typical
corner silicon, nominal temperature (25C), and nominal voltages.

BROADCOM
June 02, 2010 4706-DS00-R

Page 29
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

Core and I/O Power Sequencing Requirements

Core and I/O Power Sequencing Requirements


The BCM4706 device requires specific power sequencing between the core and I/O supplies.
The BCM4706 device power sequence requires I/O power (3.3V; 2.5V; 1.8V) to come up first, followed by
the core power (1.2V). The requirement is that the core power (1.2V) should not be on until the I/O power
(3.3V, 2.5V, 1.8V) reaches at least 1.0V.
When core power reaches nominal core voltage (1.2V 5%), the I/O power should be stable at nominal I/O
voltage (3.3V 5%, 2.5V 5%, or 1.8V 5%)
The maximum ramp-up time for core power 1.2V (from 0V to nominal voltage 5%) is 2 ms as shown in
figure below.
In addition, for successful power-up, Broadcom recommends that the external hardware reset be asserted for
at least 50 ms after both I/O and core power are stable as shown in Figure 4.

Figure 4: Power Supply Sequencing

BROADCOM
June 02, 2010 4706-DS00-R

Page 30
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

DDR2 SDRAM Memory Interface DC Characteristics

DDR2 SDRAM Memory Interface DC Characteristics


Table 7: DC Characteristics for DDR2 SDRAM Interface
Parameter

Symbol Min

Max

Units

Conditions

SSTL Reference Voltage

VREF

DDR_OVDD_1P8
0.49

DDR_OVDD_1P8
0.51

VIHDC

VREF + 0.125

DC Input Low Voltage


AC Input High Voltage
AC Input Low Voltage
DC Output High Voltage

VILDC
VIHAC
VILAC
VOH

V
V
V
V

DC Output Low Voltage


DC Output Source Current
DC Output Sink Current
Output Impedance
Termination Impedance

VOL
IOH
IOL
ZOUT
ZTERM

0.3
VREF + 0.2

DDR_OVDD_1P8 0.35

9
9
36
54
108

DDR_OVDD_1P8 +
0.3
VREF 0.125

VREF 0.2

Typically derived
from
DDR_OVDD_1P8
2

DC Input High Voltage

0.35

44
66
132

V
mA
mA

Strong termination
Weak termination

USB Host Interface DC Characteristics


Table 8: USB Host Interface DC Characteristics
Parameter

Symbol

Min

Typ

Max

Units

Conditions

VHSCM

-50

500

mV

VHSDI

300

mV

Static | VIDP VIDN |

VHSSQ

150
625

100

525

mV
mV
mV
mV

Squelch detected
No Squelch detected
Disconnect detected
Disconnect undetected

360
10

400
0

440
10

mV
mV

Static condition
Static condition

Receiver HS mode
Input Common Mode Voltage
Range
Differential Input Voltage
Sensitivity
Squelch Detection Threshold
(differential)

Disconnect Detection Threshold VHSDSC


(differential)
TransmitterHS mode
Output High Voltage
Output Low Voltage

VHSOH
VHSOL

BROADCOM
June 02, 2010 4706-DS00-R

Page 31
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

USB Host Interface DC Characteristics

Table 8: USB Host Interface DC Characteristics (Cont.)


Parameter

Symbol

Min

Typ

Max

Units

Conditions

Output Impedance

RO

40.5

45

49.5

ohm

Single-ended

Chirp-J Output Voltage


(differential)

VCHIRPJ

1100

mV

700

HS Termination
disabled RPU
connected
Chirp-K Output Voltage
VCHIRPK
-900
-500
mV
HS Termination
(differential)
disabled RPU
connected
Note: See Section 7 of the USB 2.0 specification (www.usb.org) for more info on the Receiver Eye Diagram
Template.

Table 9: USB 1.1 Electrical and Timing Parameters


Value
Parameter

Symbol

Condition

Minimum

Typical

Maximum

Units

VDI
VCM

Static |VIDP VIDN 200


|

0.8

mV

2.5

VFSOH
VFSOL
VCRS

Static condition
Static condition

2.8
0.0
1.3

3.6
0.3
2.0

V
V
V

RO

Single-ended

28

36

44

RPD

14.25

15.75

ZIN

300

ReceiverFS
Differential Input Sensitivity
(min)
Differential Common Mode
Range (max)
TransmitterFS
Output High Voltage
Output Low Voltage
Output Signal Crossover
Voltage
Output Impedance
Terminations
Bus Pull-down Resistor on
Host Port
Input Impedance

BROADCOM
June 02, 2010 4706-DS00-R

Page 32
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

PCIe DC Characteristics

PCIe DC Characteristics
Table 10 shows PCIe DC characteristics.
Table 10: PCIe DC Characteristics
Parameter

Description

Min

Typ

Max

Units

Transmitter Output Impedance (differential)


Transmitter Output Voltage (differential peak to peak)

100

1200

mVP-P

Receiver Input Impedance (differential)


Receiver Input Voltage (differential peak to peak)

175

100

2000

mVP-P

Transmitter
ZOUT
VOD
Receiver
ZIN
VID

1G SGMII/SerDes Port Signals


Table 11 shows the 1G SGMII/SerDes port signals. These signals are AC coupled.
Table 11: 1G SGMII/SerDes Port Signals
Parameter

Description

Min

Typ

Max

Units

VID
RIN
VOD

Receiver Input Voltage, differential peak to peak, AC coupled


Receiver Input Impedance, differential, integrated on-chip
Transmitter Output Voltage, differential peak-to-peak,
programmable
Transmitter Output Impedance (differential)

100
80

100
700

2000
120
1100

mV

mV

80

100

120

RO

BROADCOM
June 02, 2010 4706-DS00-R

Page 33
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

Standard 3.3V Signals

Standard 3.3V Signals


These specifications apply to all 3.3V signals, such as Flash, Serial Flash, MII, I8S/TDM, GPIO, MDC/MDIO, UART,
JTAG interfaces, and global clock/reset pins.
Table 12: Standard 3.3V Signals
Parameter

Description

Min

Typ

Max

Units

VIN
VIL
VIH
VOL
VOH
CI

Input voltage
Input low voltage
Input high voltage
Output low voltage
Output high voltage
I/O pin capacitance

0.3

2.0

2.4

3.6
0.8

0.4

10

V
V
V
V
V
pF

Standard 2.5V Signals


These specifications apply to the RGMII interface.
Table 13: Standard 2.5V Signals
Parameter

Description

Min

Typ

Max

Units

VIN
VIL
VIH
VOL
VOH
CI

Input voltage
Input low voltage
Input high voltage
Output low voltage
Output high voltage
I/O pin capacitance

0.3

1.7

2.0

2.75
0.8

0.4

10

V
V
V
V
V
pF

XTAL Oscillator Interface


Table 14: XTAL Oscillator Interface
Parameter

Symbol

Min

Max

Units

Input Low Voltage


Input High Voltage

XTALIL
XTALIH

0.3
2.0

+0.8
XTAL_PLLAVDD_3P3 + 0.5

V
V

BROADCOM
June 02, 2010 4706-DS00-R

Page 34
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

Timing Characteristics

Section 4: T iming Characteristics


Reset and Clock Timing
t210
Voltage
Rails

t204
t201

t203

XTAL_IN
(25 MHz)
t202
t208

t207

RESET_N

t209
Configuration
Strap Signals

Valid

Figure 5: Reset and Clock Timing


Table 15: Reset and Clock Timing
Parameter Description

Minimum

Typical

Maximum

Units

t201
t202
t203
t204
t207
t208
t209
t210

50
0
8.5

50

25.0000
20
20

110

10

MHz
ns
ns
ms
s
s
s
ms

XTALI frequency
XTALI high time
XTALI low time
RESET_N low pulse duration
Configuration valid setup to RESET_N rising
Configuration valid hold from RESET_N rising
RESET_N deassertion to normal operation
Reset low hold time after power supplies
stabilize

BROADCOM
June 02, 2010 4706-DS00-R

Page 35
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

Parallel Flash Timing

Parallel Flash Timing


Parallel Flash READ Timing
FLASH_ADDR[26:0]

Address Valid
t3

t2

t1

FLASH_CS[1:0]_N

FLASH_OE_N

t0

FLASH_DATA[15:0]

Data Valid

Figure 6: Parallel Flash READ Timing Diagram


Table 16: Parallel Flash READ Timing
Parameter Descriptions

Min

Typ

Max

Units

Comments

Internal reference
clock
Internal reference
clock
Internal reference
clock
Internal reference
clock

WaitCount0+
1
WaitCount1+
1
WaitCount2+
1
WaitCount3+
1

t0

Output Enable Assertion Time

32

t1

Chip Select Inactive Time

32

t2

Chip Select Low to Output Enable Low 1

32

t3

Output Enable High to Chip Select


High

32

Note: Each timing parameter can be programmed individually through the corresponding WaitCount
field on the FlashWaitCnt register.

Note: The internal reference clock runs at 150 MHz.

BROADCOM
June 02, 2010 4706-DS00-R

Page 36
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

Parallel Flash Timing

Parallel Flash WRITE Timing


FLASH_ADDR[26:0]

Address Valid
t3

t2

t1

FLASH_CS[1:0]_N

FLASH_WE_N

t0

FLASH_DATA[15:0]

Data Valid

Figure 7: Parallel Flash WRITE Timing Diagram


Table 17: Parallel Flash WRITE Timing
Parameter

Descriptions

Min

Typ

Max

Units

t0
t1
t2

Output Enable Assertion Time


Chip Select Inactive Time
Chip Select Low to Write Enable
Low
Write Enable High to Chip Select
High

1
1
1

32
32
32

Internal reference clock WaitCount0 + 1


Internal reference clock WaitCount1 + 1
Internal reference clock WaitCount2 + 1

32

Internal reference clock WaitCount3 + 1

t3

Comments

Note: Each timing parameter can be programmed individually through the corresponding WaitCount
field on the FlashWaitCnt register.

Note: The internal reference clock runs at 150 MHz.

BROADCOM
June 02, 2010 4706-DS00-R

Page 37
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

Serial Flash Timing (ST Micro-compatible Device)

Serial Flash Timing (ST Micro-compatible Device)


tp
SFlash_CLK
t1
Flash_CSx_N
t2

t3

SFlash_SI
t4
SFlash_SO
Figure 8: Serial Flash Timing Diagram
Table 18: Serial Flash Timing
Parameter

Descriptions

Min

Typ

Max

Units

fFREQ
tP
t1

SFlash_CLK frequency
Cycle time: SFlash_CLK period
Delay time: Flash_CSx_N low to SFlash_CLK rising
edge
Setup time: SFlash_SI valid to SFlash_CLK falling
edge
Hold time: SFlash_CLK falling edge to SFlash_SI
invalid
Output valid time: SFlash_SO valid to SFlash_CLK
rising edge

26.67/40
20

37.5

MHz
ns
ns

10

ns

ns

5.5

ns

t2
t3
t4

BROADCOM
June 02, 2010 4706-DS00-R

Page 38
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

DDR2 SDRAM AC Timing Characteristics

DDR2 SDRAM AC Timing Characteristics


Table 19 shows the AC characteristics for the DDR SDRAM interface.
Table 19: AC Characteristics for DDR SDRAM Interface
Parameter Description

Min

Typ

Max

Units

tCK(avg)

Average clock period (programmable) 3.33

ns

tCH(avg)

Average clock HIGH pulse width

0.48

0.5

0.52

tCK(avg)

tCL(avg)

Average clock LOW pulse width

0.48

0.5

0.52

tCK(avg)

tJIT(per)
tJIT(cc)
tJIT(duty)
tDQSS

125
250
125
250

125
250
125
250

ps
ps
ps
ps

tDQSH

Clock period jitter


Cycle to cycle clock period jitter
Duty cycle jitter
DQS latching rising transitions to
associated clock edges (for write, also
related to tDSS, tDSH)
DQS HIGH pulse width (for write)

0.35

0.5

tCK(avg)

tDQSL

DQS LOW pulse width (for write)

0.35

0.5

tCK(avg)

tWPRE

Write preamble, DQS driver turn-on to 0.35


the first DQS edge
Write postamble, DQS time to high-Z 0.4
after the last falling DQS edge
Delay from clock to address and control
signals, VDL adjustable (related to tIS,
tIH at DDR2 SDRAM)
Control and address output pulse width 0.6

tCK(avg)

tCK(avg)

0.25

tCK(avg)

tCK(avg)

0.25

tCK(avg)

0.35

tCK(avg)

400

ns
ns
ns

tWPST
tCK2AC
tIPW

tWDQ2DQS Delay from DQ or DM to DQS, VDL


adjustable (for write, related to tDS,
tDH at DDR2 SDRAM)
tDIPW
DQ and DM output pulse width (for
write)
tDQSCK
DQS delay from clock (for read)
tRDQDQSS DQ to DQS setup time (for read)
tRDQDQSH DQ hold time after DQS (for read)

400

0.2-tCK(avg)/4
tCK(avg)/4+0.2

BROADCOM
June 02, 2010 4706-DS00-R

Page 39
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

USB Host Interface AC Timing Characteristics

USB Host Interface AC Timing Characteristics


Table 20: USB 2.0 Host Interfaces Timing Parameters
Parameter

Symbol

Min

Typ

Max

Units

Conditions

Baud Rate
Units Interval

BPS
UI

480
2083

Mbps
ps

THSRX

0.15

0.15

UI

THSR
THSF
THSTX

500
500
0.05

0.05

ps
ps
UI

10% to 90%
90% to 10%

Receiver HS mode
Receiver Jitter Tolerance
TransmitterHS mode
Output Rise Time
Output Fall Time
TX Output Jitter

Table 21: USB 1.1 Timing Parameters


Value
Parameter

Symbol

Condition Min

Typ

12

83.33
To next
18.5

transition
RX Jitter Tolerance
TJR2
For paired 9

transitions
Output Rise Time
TFSR
10 to 90% 4

Output Fall Time


TFSF
10 to 90% 4

Note: For details, see the USB 1.1 Specification, Section 7.3.2, Tables 7-5 and 7-6.
Baud Rate
Units Interval
RX Jitter Tolerance

BPS
UI
TJR1

BROADCOM
June 02, 2010 4706-DS00-R

Max

Units

18.5

Mbps
ns
ns

ns

20
20

ns
ns

Page 40
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

PCIe Interface Timing

PCIe Interface Timing


PCIe_REFCLKP/N Timing
Figure 9 shows PCIe_REFCLKP/N timing.

PCIe_REFCLKP/N

TF

TJ

TR

T CYCLE

Figure 9: PCIe_REFCLKP/N Timing


Table 22: PCIe_REFCLKP/N Timing
Parameter

Descriptions

Min

Typ

Max

Units

FREQ
TOL
VID
tR/tF
tJ

Frequency (1/TCYCLE)
Tolerance
Differential peak-to-peak amplitude
Rise/Fall time
Max RMS (10 kHz to 50 MHz)

50
1.32

100

+50
1.70
1.0
4.7

MHz
ppm
VP-P
ns
ps

PCIe[1:0]_RDP/N Timing
Figure 10 shows PCIe[1:0]_RDP/N timing.

TJITTER
PCIe[1:0]_RDP/N

Figure 10: PCIe[1:0]_RDP/N Timing

BROADCOM
June 02, 2010 4706-DS00-R

Page 41
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

PCIe Interface Timing

Table 23: PCIe[1:0]_RDP/N Timing


Parameter

Descriptions

Min

Typ

Max

Units

FREQ
ZIN
VID
tJ

Baud rate
Input impedance (differential)
Differential peak-to-peak input voltage
Jitter tolerance (minimum RX EYE width)

175
0.4

2.5
100

2000

GBaud

mVP-P
UI

PCIe[1:0]_TDP/N Timing
Figure 11 shows PCIe[1:0]_TDP/N timing.

TJITTER

PCIe[1:0]_TDP/N

TR

TF

Figure 11: PCIe[1:0]_TDP/N Timing


Table 24: PCIe[1:0]_TDP/N Timing
Parameter

Descriptions

Min

Typ

Max

Units

FREQ
ZOUT
VOD
TR/TF
tJ

Baud rate
Output impedance (differential)
Differential peak-to-peak output voltage
Output rise/fall time (20% to 80%)
Output jitter (minimum TX EYE width)

0.125
0.7

2.5
100

1200

GBaud

mVP-P
UI
UI

BROADCOM
June 02, 2010 4706-DS00-R

Page 42
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

MII Interface Timing

MII Interface Timing


This section shows timing information for the MII Interface pins.

MII Input Timing


t402
t401

t403

t404

GMAC_RXCLK

GMAC_RXDV
GMAC_RXD[3:0]

Figure 12: MII Input Timing


Table 25: MII Input Timing
Parameter Description
t401
t402
t403
t404

Min

GMAC_RXDV, GMAC_RXD[3:0] to GMAC_RXC rising setup


10
time
GMAC_RXC clock period (10BASE-T mode)

GMAC_RXC clock period (100BASE-TX mode)

GMAC_RXC high/low time (10BASE-T mode)


160
GMAC_RXC high/low time (100BASE-TX mode)
16
GMAC_RXDV, GMAC_RXD[3:0] to GMAC_RXC rising hold time 10
Duty cycle
40

BROADCOM
June 02, 2010 4706-DS00-R

Typ

Max

Units

ns

400
40

50

240
24

60

ns
ns
ns
ns
ns
%

Page 43
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

MII Interface Timing

MII Output Timing

GMAC_TXCLK

GMAC_TXEN
GMAC_TXD[3:0]

Figure 13: MII Output Timing


Table 26: MII Output Timing
Parameter Description

Min

Typ

Max

Units

t405
t406

0
0

25

ns
ns

GMAC_TXC high to GMAC_TXEN, GMAC_TXD[3:0] valid


GMAC_TXC high to GMAC_TXEN, GMAC_TXD[3:0] invalid
(hold)

BROADCOM
June 02, 2010 4706-DS00-R

Page 44
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

RGMII Interface Timing

RGMII Interface Timing


The following specifies timing information for the GMAC interface pins when configured in RGMII mode.

RGMII Output Timing (Normal Mode)


RGMII output timing defaults to the normal mode when the FLASH_ADDR22/TX_DELAY_MODE pin is pulled
low at power-on reset.

GMAC_TXCLK

GMAC_TXD[3:0]

Figure 14: RGMII Output Timing (Normal Mode)


Table 27: RGMII Output Timing (Normal Mode)
Parameter Description

Min

Typ

Max

GMAC_TXCLK clock period (1000M mode)


7.2
8.0 8.8

GMAC_TXCLK clock period (100M mode)


36
40
44

GMAC_TXCLK clock period (10M mode)


360
400 440
t201
Tskew: Data to clock output skew
500 (1000M)
+500 (1000M)

Duty cycle for 1000M (GE)


45
50
55

Duty cycle for 10/100M (FE)


40
50
60
Note: The output timing in 10/100M operation is always as specified in the delayed mode.

BROADCOM
June 02, 2010 4706-DS00-R

Units
ns
ns
ns
ps
%
%

Page 45
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

RGMII Interface Timing

RGMII Output Timing (Delayed Mode)


RGMII output timing is set to the delayed mode when the FLASH_ADDR22/TX_DELAY_MODE pin is pulled high
at power-on reset.

GMAC_TXCLK
(internal)
Delayed
GMAC_TXCLK
(actual output
at source)

GMAC_TXD[3:0]

Figure 15: RGMII Output Timing (Delayed Mode)


Table 28: RGMII Output Timing (Delayed Mode)
Parameter Description

Min

Typ Max Units

t201D

7.2
36
360
1.2 (all speeds)

8.0 8.8
40 44
400 440
2.0

ns
ns
ns
ns

1.2

2.0

ns

45
40

50
50

55
60

%
%

t202D

GMAC_TXCLK clock period (1000M mode)


GMAC_TXCLK clock period (100M mode)
GMAC_TXCLK clock period (10M mode)
Tsetup, data valid to clock transition:
Available setup time at the output source (delayed mode)
Thold, clock transition to data valid:
Available hold time at the output source (delayed mode)
Duty cycle for 1000M (GE)
Duty cycle for 10/100M (FE)

BROADCOM
June 02, 2010 4706-DS00-R

Page 46
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

RGMII Interface Timing

RGMII Input Timing (Normal Mode)


RGMII Input Timing defaults to the delayed mode when the FLASH_ADDR23/RX_DELAY_MODE pin is pulled
low at power-on reset. The receive clock will not be delayed with 2 ns internally.

GMAC_RXCLK
(internal)

GMAC_RXCLK
(actual)

GMAC_RXD[3:0]

Figure 16: RGMII Input Timing (Normal Mode)


Table 29: RGMII Input Timing (Normal Mode)
Parameter Description

Min Typ Max Units

t301
t302

7.2
36
360
1.0
1.0
45
40

GMAC_RXCLK clock period (1000M mode)


GMAC_RXCLK clock period (100M mode)
GMAC_RXCLK clock period (10M mode)
Tsetup, input setup time: valid data to clock
Thold, input hold time: clock to valid data
Duty cycle for 1000M (GE)
Duty cycle for 10/100M (FE)

BROADCOM
June 02, 2010 4706-DS00-R

8.0
40
400
2.0
2.0
50
50

8.8
44
440

55
60

ns
ns
ns
ns
ns
%
%

Page 47
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

RGMII Interface Timing

RGMII Input Timing (Delayed Mode)


RGMII Input Timing is set to the delayed mode when the FLASH_ADDR23/RX_DELAY_MODE pin is pulled high
at power-on reset. The receive clock will be delayed with 2 ns internally.

GMAC_RXCLK
(internal)
Delayed
GMAC_RXCLK
(actual output
at destination)

GMAC_RXD[3:0]

Figure 17: RGMII Input Timing (Delayed Mode)


Table 30: RGMII Input Timing (Delayed Mode)
Parameter Description

Min

Typ

Max

Units

t301D
t302D

-1.0 (10/100/1000M)
3.0 (1000M)
9.0 (10/100M)

ns
ns
ns

Tsetup, input setup time (delayed mode)


Thold, input hold time (delayed mode)

BROADCOM
June 02, 2010 4706-DS00-R

Page 48
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

SGMII/SerDes Serial Interface

SGMII/SerDes Serial Interface


This subsection specifies timing information for the serial interface.

Serial Interface Output Timing


SGMII_TXDP

SGMII_TXDN

t805

t803

t802

Figure 18: Serial Interface Output Timing


Table 31: Serial Interface Output Timing
Parameter Description

Min

Typ

Max

Units

t801
t802
t803
t804
t805

100
100

1.25

200
200

0.24

GBaud
ps
ps
ps
UI

Transmit Data Signaling Speed


Transmit Data Rise Time (20%-80%)
Transmit Data Fall Time (20%- 80%)
Transmit Data Output Differential Skew
Transmit Data Total Jitter

BROADCOM
June 02, 2010 4706-DS00-R

Page 49
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

SGMII/SerDes Serial Interface

Serial Interface Input Timing


SGMII_RXDP

SGMII_RXDN

t808

Figure 19: Serial Interface Input Timing


Table 32: Serial Interface Input Timing
Parameter Description

Min

Typ

Max

Units

t806
t808

1.25

0.6

GBaud
UI

Receive Data Signaling Speed


Receive Data Jitter (peak-to-peak)

BROADCOM
June 02, 2010 4706-DS00-R

Page 50
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

I8S/TDM Audio/Video AC Specification

I8S/TDM Audio/Video AC Specification


Tperiod

TDM[1:0]_BITCLK
Thigh

Tlow

TDM[1:0]_WS or
TDM[1:0]_SDIO
T pd

Figure 20: IXS Transmitter Timing

Tperiod

TDM[1:0]_BITCLK
Thigh

Tlow

TDM[1:0]_WS or
TDM[1:0]_SDIO
T hold

Tsetup

Figure 21: IXS Receiver Timing


I

Table 33: IXS Receiver Timing


Parameter

Description

Min

Max Units Conditions

Tcyc
Tperiod
Thigh
Tlow
Tduty_cyc
Tpd

TDM[1:0]_BITCLK frequency
TDM[1:0]_BITCLK period
TDM[1:0]_BITCLK high
TDM[1:0]_BITCLK low
TDM[1:0]_BITCLK duty cycle
TDM[1:0]_BITCLK to TDM[1:0]_WS or TDM[1:0]_SDIO
delay
TDM[1:0]_WS or TDM[1:0]_SDIO setup time
TDM[1:0]_WS or TDM[1:0]_SDIO hold time

DC
13.33
5.33
5.33
40

75

8
8
60
3

MHz
ns
ns
ns
%
ns

Programmable

Output mode

2
2

ns
ns

Input mode
Input mode

Tsetup
Thold

BROADCOM
June 02, 2010 4706-DS00-R

Page 51
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

JTAG Interface

JTAG Interface
JTAG timing is synchronous to the JTCK clock.

Figure 22: JTAG Interface


Table 34: JTAG Interface
Parameter

Description

Min

Typ

Max

Units

TCYCLE
TSU
TH
TOD

JTAG Cycle Time


Input Setup Time
Input Hold Time
Output Delay Time Measured from Falling Edge of JTCK

50
10
10

22

ns
ns
ns
ns

BROADCOM
June 02, 2010 4706-DS00-R

Page 52
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

MDC/MDIO Master Interface

MDC/MDIO Master Interface


MDIO timing is synchronous to the MDC clock. The BCM4706 is an MDC/MDIO master device that drives the
MDC clock.

t1
MDC
t2
MDIO (out)
t3

t4

MDIO (in)
Figure 23: MDC/MDIO Master Interface
Table 35: MDC/MDIO Master Interface
Parameter

Description

Min

Typ

Max

Units

t1
t2
t3
t4

MDC cycle time, software programmable


MDIO output delay from MDC falling
MDIO input setup time to MDC rising
MDIO input hold time to MDC rising

40/60a

20
0

15

ns
ns
ns
ns

a. Six internal reference clock cycles, which is 40 ns.

BROADCOM
June 02, 2010 4706-DS00-R

Page 53
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

SPI Master Interface

SPI Master Interface


BCM4706 GPIO pins can be configured as SPI master interfaces to connect up to three SPI slaves. This supports
all four combinations of clock phase and polarity.

Timing Parameters for CPHA=0


tp
SCLK
(GPIO0)

CPHA=0
CPOL=0

CPOL=0

CPOL=1

CPOL=1

SS0/1/2
(GPIO1/8/9)

t2

t1
t3

MOSI
(GPIO2)
t4

t5

MISO
(GPIO3)
Figure 24: SPI Master Interface: Timing Parameters for CPHA=0
Table 36: SPI Master Interface
Parameter Description
tp
t1
t2
t3
t4
t5

Min

SCLK period, software programmable


80
Minimum leading time before the first SCLK edge

Minimum trailing time after the last SCLK edge

MOSI output delay from SCLK clock falling/rising (CPOL=0/


1)
MISO input setup time to SCLK clock rising/falling (CPOL=0/ 10
1)
MISO input hold time to SCLK clock rising/falling (CPOL=0/1) 10

BROADCOM
June 02, 2010 4706-DS00-R

Typ

Max

Units

1.5
0.5

10

ns

ns

ns

tp
tp

ns

Page 54
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

SPI Master Interface

Timing Parameters for CPHA=1


tp
SCLK
(GPIO0)

CPHA=1
CPOL=0

CPOL=0

CPOL=1

CPOL=1

SS0/1/2
(GPIO1/8/9)

t2

t1
t3

MOSI
(GPIO2)
t4

t5

MISO
(GPIO3)
Figure 25: SPI Master Interface: Timing Parameters for CPHA=1
Table 37: Timing Parameters for CPHA=1
Parameter

Description

Min

Typ

Max

Units

tp
t1
t2
t3

SCLK period, software programmable


Minimum leading time before the first SCLK edge
Minimum trailing time after the last SCLK edge
MOSI output delay from SCLK clock rising/falling
(CPOL=0/1)
MISO input setup time to SCLK clock falling/rising
(CPOL=0/1)
MISO input hold time to SCLK clock falling/rising
(CPOL=0/1)

80

1
1

10

ns

10

ns

10

ns

t4
t5

BROADCOM
June 02, 2010 4706-DS00-R

tp
tp

ns

Page 55
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

Thermal Specifications

Section 5: Thermal Specifications


This section describes the device thermal specifications. The maximum ThetaJA is a function of the maximum
ambient air temperature of the system.

BCM4706
This subsection describes BCM4706 device thermal specifications.

BCM4706 Thermal Specifications Without External Heatsink at 70C


Table 38 and Table 39 show the simulation and thermal performance data on the 2s2p board, without external
heatsink. The maximum ThetaJA is a function of the maximum ambient air temperature of the system.
Table 38: Package for 2s2p Board,
TA = 70C, P = 2.7W from Simulation
Parameter

Value

Device power dissipation, P(W)


Ambient air temperature TA (C)
JA in still air (C/W)
JB (C/W)
JC (C/W)

2.70
70
21.43
9.80
8.81

Table 39: BCM4706 Thermal Specifications Without External Heatsink at 70C


Air Velocity
m/s

ft/min

TJ_max (C)

TT_ (C)

JA (C/W)

JT (C/W)

JB (C/W)

0
0.508
1.016
2.032
3.048

0
100
200
400
600

127.86
122.36
119.63
116.60
114.87

109.20
103.65
100.86
97.73
95.93

21.43
19.39
18.38
17.26
16.62

6.91
6.93
6.95
6.99
7.02

12.25
12.16
12.05
11.89
11.78

BROADCOM
June 02, 2010 4706-DS00-R

Page 56
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

BCM4706

BCM4706 Thermal Specifications with External Heatsink at 70C


Table 40 and Table 41 show the simulation and thermal performance data with the 30x30x25 mm external
heatsink for the 2s2p board. The maximum ThetaJA is a function of the maximum ambient air temperature of
the system.
Table 40: Package with 30x30x25 mm External Heat Sink on 2s2p Board,
TA = 70C, P = 2.7W from Simulation
Parameter

Value

Device power dissipation, P(W)


Ambient air temperature TA (C)
JA in still air (C/W)
JB (C/W)
JC (C/W)

2.70
70
15.33
9.80
8.81

Table 41: BCM4706 Thermal Specifications with 30x30x25 mm External Heatsink at 70C
Air Velocity
m/s

ft/min

TJ_max (C)

TT_ (C)

JA (C/W)

JT (C/W)

JB (C/W)

0
0.508
1.016
2.032
3.048

0
100
200
400
600

111.39
101.31
99.42
98.31
97.81

90.63
79.98
77.98
76.83
76.32

15.33
11.59
10.90
10.48
10.30

7.69
7.90
7.94
7.96
7.96

9.77
9.08
8.94
8.87
8.85

BROADCOM
June 02, 2010 4706-DS00-R

Page 57
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

BCM4706

BCM4706 Thermal Specifications Without External Heatsink at 85C


Table 42 and Table 43 show the simulation and thermal performance data on the 2s2p board, without external
heatsink. The maximum ThetaJA is a function of the maximum ambient air temperature of the system.
Table 42: Package for 2s2p Board,
TA = 85 C, P = 2.7 W from Simulation
Parameter

Value

Device power dissipation, P(W)


Ambient air temperature TA (C)
JA in still air (C/W)
JB (C/W)
JC (C/W)

2.70
85
21.43
9.80
8.81

Table 43: BCM4706 Thermal Specifications Without External Heatsink at 85C


Air Velocity
m/s

ft/min

TJ_max (C)

TT_ (C)

JA (C/W)

JT (C/W)

JB (C/W)

0
0.508
1.016
2.032
3.048

0
100
200
400
600

142.86
137.36
134.63
131.60
129.87

124.20
118.65
115.86
112.73
110.93

21.43
19.39
18.38
17.26
16.62

6.91
6.93
6.95
6.99
7.02

12.25
12.16
12.05
11.89
11.78

BROADCOM
June 02, 2010 4706-DS00-R

Page 58
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

BCM4706

BCM4706 Thermal Specifications with External Heatsink at 85C


Table 44 and Table 45 show the simulation and thermal performance data with the 30x30x25 mm external
heatsink for the 2s2p board. The maximum ThetaJA is a function of the maximum ambient air temperature of
the system.
Table 44: Package with 30x30x25 mm External Heat Sink on 2s2p Board,
TA = 85C, P = 2.7W from Simulation
Parameter

Value

Device power dissipation, P(W)


Ambient air temperature TA (C)
JA in still air (C/W)
JB (C/W)
JC (C/W)

2.70
85
15.33
9.80
8.81

Table 45: BCM4706 Thermal Specifications with 30x30x25 mm External Heatsink at 85C
Air Velocity
m/s

ft/min

TJ_max (C)

TT_ (C)

JA (C/W)

JT (C/W)

JB (C/W)

0
0.508
1.016
2.032
3.048

0
100
200
400
600

126.39
116.31
114.42
113.31
112.81

105.63
94.98
92.98
91.83
91.32

15.33
11.59
10.90
10.48
10.30

7.69
7.90
7.94
7.96
7.96

9.77
9.08
8.94
8.87
8.85

BROADCOM
June 02, 2010 4706-DS00-R

Page 59
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

Mechanical Information

Section 6: Mechanical Information


BCM4706

Figure 26: BCM4706 Mechanical Information

BROADCOM
June 02, 2010 4706-DS00-R

Page 60
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

Ordering Information

Section 7: Ordering Information


Table 46: Ordering Information
Part Number

Package

Ambient Temperature

BCM4706KPBG

23 mm x 23 mm 484-pin PBGA (Lead-free)

0 to 70C

BROADCOM
June 02, 2010 4706-DS00-R

Page 61
4/12/2011 DXKOG

BCM4706 Advance Data Sheet

Broadcom Corporation reserves the right to make changes without further notice to any products
or data herein to improve reliability, function, or design.
Information furnished by Broadcom Corporation is believed to be accurate and reliable. However,
Broadcom Corporation does not assume any liability arising out of the application or use of this
information, nor the application or use of any product or circuit described herein, neither does it
convey any license under its patent rights nor the rights of others.

BROADCOM CORPORATION

5300 California Avenue


Irvine, CA 92617
2010 by BROADCOM CORPORATION. All rights reserved.
4706-DS00-R

June 02, 2010


4/12/2011 DXKOG

Phone: 949-926-5000
Fax: 949-926-5203
E-mail: info@broadcom.com