NEC Cooperation
CONTENTS
Part1
Part2
Part3
LCT
LCTCONNECTION
CONNECTION
ALL
ALLMENUS
MENUS
ITEMS
ITEMSMEANING
MEANINGIN
INMENUS
MENUS
&&HOW
HOWTO
TOUSE
USEIT
IT
PASOLINK Introduction
TARGETS
KNOW HOW TO LOGIN LCT
KNOW ITEMS MEANING IN MENUS
KNOW HOW TO USE ITEMS IN MENUS
PASOLINK Introduction
PASOLINK Introduction
PASOLINK Introduction
HYPER-TERMINAL SETTING
PASOLINK Introduction
LCT--MENUS
(1+0)
5.CAS
6.CRC
99.Exit
TX power :*.**
RX level :*.**
Manufactured date
Software version
Bit rate
Option module
Manufactured date
Sub band
Start frequency
Shift frequency
PASOLINKSerial
Introduction
number
ODU
Software version
Bit rate
RF band
ODU
Monitoring
1. Monitoring voltage
2. Monitoring voltage (con mode)
3. Alarm/Status
4. Inventory
00. Menu
99. Exit
4.Framing
00.Menu
IDU
Maintenance
(1+1)
3.Flow ctrl
7.Collion Report
IDU
4.Exit
1. MAINT
2. FE loop back ctrl 1-16
3. NE loop back ctrl 1-16
4. BER ALM >> AIS
5. CW
6. Power mute
7. ATPC manual ctrl
00. Menu
99. Exit
1. to 5. same as 1+0
6. Power mute1
7. Power mute2
8. TX SW ctrl
9. RX SW ctrl
10. ATPC manual ctrl
00. & 99. same as 1+0
1. Port1 setting
2. Port2 setting
3. FE link down
00. Menu
99. Exit
2.Mode
Alarm Table
3.Monitoring
1. System configuration
2. LAN setting
3. Channel usage error
00. Menu
99. Exit
1.Thoughtput
Port setting
2.Maintenance
Maintenance
1.Setting
1. ATPC/MTPC
2. MTPC TX power
3. ATPC TX power range
4. ODU ALM mode
5. RX threshold
00. Menu
99. Exit
LAN setting
Next Item
Password Change:
TX power ctrl
Setting
Password:
TX PWR ALM
RX LEV ALM
APC 1 ALM
APC2 ALM
IF INPUT ALM
MUTE
TX FREQ CH
RX FREQ CH
Password :********
Change Password? (No:0/Yes:1) :1
New Password :********
New Password (Re-enter) : * * * * * * * *
1. Setting
2. Maintenance
3. Monitoring
99. Exit
Select Function No. :
PASOLINK Introduction
SETTING MENU
1. Setting
2. Maintenance
3. Monitoring
4. Exit
Select Function No:
Setting
1. Bit rate
(1 6x2MB)
2. AIS RCVD alarm/status (alarm)
3. AIS SEND alarm/status (alarm)
4. TX/RX frequency
(4ch)
5. TX power ctrl
(ATPC)
6. Main channel usage 1 - 16 (used: UUNN NNNN UUNN
NNNN)
7. BER alarm threshold
(10-3)
8. Frame ID (1)
9. WS channel usage
(on)
1 0.DSC1
(232)
11 .DSC2
(232)
12.DEM invert
(off)
13.Alarm table
14.Next items
00.Menu
99.Exit
Select Item No. :
PASOLINK Introduction
10
Setting
2. AIS RCVD alarm/status (status)
1. Bit rate (1 6x2MB)
Press 2 and Enter
2. AIS RCVD alarm/status (status)
AIS RCVD alarm/status
Press
3
and
Enter
3. AIS SEND alarm/status (status)
(status:0 /alarm :1)
4. TX/RX frequency
(4ch)
5. TX power ctrl
(ATPC)
3. AIS SEND alarm/status (alarm)
6. Main channel usage 1 - 16 (used: UUNN
NNNN UUNN NNNN)
AIS SEND alarm/status
7. BER alarm threshold (10-3)
(status:0 /alarm :1 )
8. Frame ID
(1)
9. WS channel usage (on)
Note:
1 0.DSC1 (232)
When AIS SEND is set to alarm , and AIS is sent out
11 .DSC2 (232)
the front panel IDU alarm LED lights. When AIS
12.DEM invert
(off)
SEND is set to status and AIS is sent out, no
13.Alarm table
alarm indication is initiated.
14.Next items
00. Menu
When AIS RCVD is set to alarm , on reception of AIS
99. Exit
the front panel IDU alarm LED lights. When AIS
Select Item No. :
RCVD is set to status on reception of AIS no
alarm indication is initiated.
PASOLINK Introduction
11
PASOLINK Introduction
12
1. ATPC/MTPC (ATPC)
ATPC/MTPC (MTPC:0 /
ATPC:1) :0
PASOLINK Introduction
13
(-55dBm)
PASOLINK Introduction
PASOLINK Introduction
15
8. Frame ID(2)
Input ID No. (0-7): 1
Setting
1. Bit rate
(1 6x2MB)
2. AIS RCVD alarm/status (status)
3. AIS SEND alarm/status (status)
4. TX/RX frequency
(4ch)
5. TX power ctrl
(ATPC)
6. Main channel usage 1 - 16 (used: UNNN
#### #### ####)
7. BER alarm threshold (10-3)
8. Frame ID (1)
9. WS channel usage
(on)
1 0.DSC1
(232)
11 .DSC2
(232)
12.DEM invert
(off)
13.Alarm table
14.Next items
00. Menu
99. Exit
Select Item No. : 5
PASOLINK Introduction
DSC ASSIGNMENT
Setting
1. Bit rate (1 6x2MB)
2. AIS RCVD alarm/status (status)
3. AIS SEND alarm/status (status)
4. TX/RX frequency
(4ch)
5. TX power ctrl
(ATPC)
6. Main channel usage 1 - 16 (used:
UNNN #### #### ####)
7. BER alarm threshold (10-3)
8. Frame ID
(1)
9. WS channel usage (on)
1 0.DSC1 (232)
11 .DSC2 (232)
12.DEM invert
(off)
13.Alarm table
14.Next items
00. Menu
99. Exit
Select Item No. : 5
17
WS CHANNEL USAGE
The WS option is applicable only on the 16x2 MB system with WS
INTFC mounted. In this case if WS E1 channel is not used, set
this to not use inhibit alarms.
When the WS INTFC module (optional) is not mounted, this menu item
is not displayed.
9. WS channel usage (not used)
WS Channel usage (used:0 / not used:1) : 0
12.DEM invert (off)
DEM invert (off:0 / on:1) :
DEM INVERT
When the ODU receive signal is down converted the signal sent
to the IDU may have a normal or inverted spectrum.
18
ALARM TABLE
Setting
1. Bit rate (1 6x2MB)
2. AIS RCVD alarm/status (status)
3. AIS SEND alarm/status (status)
4. TX/RX frequency
(4ch)
5. TX power ctrl
(ATPC)
6. Main channel usage 1 - 16 (used:
UUNN NNNN UUNN NNNN)
7. BER alarm threshold (10-3)
8. Frame ID
(1)
9. WS channel usage (on)
1 0.DSC1 (232)
11 .DSC2 (232)
12.DEM invert
(off)
13.Alarm table
14.Next items
00. Menu
99. Exit
Select Item No. : 5
This menu item defines the external relay
outputs. The alarms are sent out
through four relays(1 +0) or six
relays(1 +1). Multiple alarms can be
assigned to any relay and alarms can
be assigned to multiple relays.
C1 C2 C3 C4 C5 C6
1.INPUT LOSS
OUT OUT --- --- --- --2.AIS RCVD
--- --- --- --- --- --3.AIS SEND
--- --- --- --- --- --4.OUTPUT LOSS
--- --- OUT OUT --- --5.TX CLK LOSS
OUT --- --- --- --- --- --larm table 2/3
C1 C2 C3 C4 C5 C6
9.FSYNC ALM1
--- --- OUT --- --- --11.HIGH BER ALM1 --- --- OUT --- --- --12.HIGH BER ALM2 --- --- --- OUT --- --13.LOW BER ALM1
--- --- --- --- --- --15.BER ALM
--- --- OUT --- OUT --17.MOD ALM1
OUT --- --- --- --- --19.DEM ALM1
--- --- OUT --- --- --21.OPR ALM1
OUT --- OUT --- --- --23.TX PWR ALM
OUT --- --- --- --- --25.RX LEV ALM1
--- --- OUT --- --- --------33.MAINT
MASK MASK MASK MASK MASK OUT
PASOLINK Introduction
19
(1+0) expandable configuration is selected when in an (1+1) hardware configuration only one channel IDU
and ODU is equipped or used. Other channel alarms are inhibited.
(1+1) Hot standby only one channel is transmitted at a time but receive from both channels and select one.
(1+1) Twin Path both channels transmit andPASOLINK
use two different
frequencies.
Introduction
20
Port setting
LAN setting
1. Port1 setting
2. Port2 setting
3. FE link down
00. Menu
99. Exit
3.Flow ctrl
4.Framing
5.CAS
6.CRC
7.Collion Report
00.Menu
0. Disable
1.
2M
2.
4M
3.
8M
4.
16M
5.
32M
99.Exit
Mode Setting
Port setting
Next item
1.System configuration
2. LAN setting
3. Channel usage error
00. Menu
99. Exit
Select Item No. : 5
2.Mode
Throughput setting
0. AUTONEG (Auto-MDI/MDIX)
1.10M-Half (MDI)
2.10M-Full (MDI)
3.100M-Half (MDI)
4.100M Full (MDI)
5 .10M-Half (MDIX)
6.10M-Full (MDIX)
7.100M-Half (MDIX)
8.100M Full (MDIX)
00. Menu
99. Exit
Port setting
1.Thoughtput
2.Mode
3.Flow ctrl
4.Collion Report
00.Menu
99.Exit
PASOLINK Introduction
21
PASOLINK Introduction
22
PASOLINK Introduction
23
1. Throughput (disable)
Throughput (disable:0 / 2M:1 / 4M:2 / 8M:3 / 16M:4 / 32M:5) :1
1. Port 1 setting
1. Throughput
(2M)
2 .Mode
(AUTONEG(AUTO-MDI/MDIX))
3. Flow ctrl (off)
4. Framing (on)
5. CAS
(on)
6. CRC
(on)
7. Collision report (report)
00. Menu
99. Exit
4. Framing (off)
Framing ( off : 0 / on : 1 ) :
5. CAS (off)
Applies when Port throughput is set to 2MB with Framing ON. If CAS is ON
LAN data is also sent in TS16. IF CAS is off then LAN data is not sent in
TS16. PASOLINK Introduction
24
1. Port 1 setting
1. Throughput
(2M)
2 .Mode
(AUTONEG(AUTO-MDI/MDIX))
3. Flow ctrl (off)
4. Framing (on)
5. CAS
(on)
6. CRC
(on)
7. Collision report (report)
00. Menu
99. Exit
2. Mode
(10M-HALF(MDI))
10M-HALF(MDI) :1 / 10M-FULL(MDI) :2
100M-HALF(MDI) :3 / 100M-FULL(MDI) :4
10M-HALF(MDIX) :5 / 10M-FULL(MDIX) :6
1 00M-HALF(MDIX):7 / 1 00M-FULL(MDIX):8
Select No. :2
PASOLINK Introduction
25
MAINTENANCE
1. Setting
2. Maintenance
3. Monitoring
4. Exit
Select Function No:
To display the Maintenance menu, press
[2] and [Enter] from the LCT main
menu.
The first item in the maintenance menu shows
the status of the maintenance mode
(Normal or MAINT).
The Maintenance Menu is used to carry out
the following functions.
Maintenance ON/OFF
Far end loop back
Near end loop back
Transmit CW carrier
Stop Transmission (Mute)
BER AIS insertion ON/OFF
TX and RX manual switching(1+1)
Manual ATPC control
Maintenance
1. MAINT
(NORM)
2. FE loop back ctrl 1-16 (ctrl:---- ---- ---- ----)
(ans :---- ---- ---- ----)
3. NE loop back ctrl 1-16 (ctrl:---- ---- ---- ----)
(ans :---- ---- ---- ----)
4. BER ALM >> AIS
(on)
5. CW
(off)
6. Power mute1
(off)
7. Power mute2
(off)
8. TX SW ctrl
(AUTO)
9. RX SW ctrl
(AUTO)
10. ATPC manual ctrl
(off)
00. Menu
99. Exit
The maintenance items 7, 8, and 9 applies to (1+ 1) configuration
If TX power control mode is MTPC menu item 10 is not displayed
MAINT (Normal:0 / MAINT:1) : 0
When the maintenance mode is on, or any of the maintenance
control items are on, the front panel MAINT LED (amber)
lights.
PASOLINK
Introduction
26
FE LOOP-BACK
Maintenance
1. MAINT
(NORM)
2. FE loop back ctrl 1-16 (ctrl:---- ---- ---- ----)
(ans :---- ---- ---- ----)
3. NE loop back ctrl 1-16 (ctrl:---- ---- ---- ----)
(ans :---- ---- ---- ----)
4. BER ALM >> AIS
(on)
5. CW
(off)
6. Power mute1
(off)
7. Power mute2
(off)
8. TX SW ctrl
(AUTO)
9. RX SW ctrl
(AUTO)
10. ATPC manual ctrl
(off)
00. Menu
99. Exit
* An asterisk on the cont line indicates that the loopback control is sent to the selected channel
* An asterisk on the ans line indicates that the loopback control was successfully carried out on the selected channel
z A z on the cont line indicates that the loopback control was initiated from the opposite station IDU
# E1 channel is inhibited by hardware restrictions or LAN signal transmission usage
PASOLINK Introduction
27
NE LOOP-BACK
Maintenance
1. MAINT
(NORM)
2. FE loop back ctrl 1-16 (ctrl:---- ---- ---- ----)
(ans :---- ---- ---- ----)
3. NE loop back ctrl 1-16 (ctrl:---- ---- ---- ----)
(ans :---- ---- ---- ----)
4. BER ALM >> AIS
(on)
5. CW
(off)
6. Power mute1
(off)
7. Power mute2
(off)
8. TX SW ctrl
(AUTO)
9. RX SW ctrl
(AUTO)
10. ATPC manual ctrl
(off)
00. Menu
99. Exit
PASOLINK Introduction
28
:1
PASOLINK Introduction
29
PASOLINK Introduction
30
MONITORING
1. Setting
2. Maintenance
3. Monitoring
4. Exit
Select Function No:
Press [3] and [Enter] from the
LCT main Menu to display
the Monitoring menu.
The monitoring menu is used to
monitor the equipment for
preventive maintenance
purposes. This menu
provides monitoring of the
Transmit and Receive signal
levels. Equipment status and
alarm can also be monitored
from this menu. Inventory list
provides details of the
modules in the equipment
Monitoring
1. Monitoring voltage
2. Monitoring voltage
(continuous mode)
3. Alarm/Status
4. Inventory
00. Menu
Monitoring voltage
TX power1 :4.10V (< -5dB)
RX level1 :2.37V ( -61dBm)
TX power2 :*.**
RX level2 :*.**
PASOLINK Introduction
31
ALARM/STATUS MONITORING
Monitoring
1. Monitoring voltage
2. Monitoring voltage
(continuous mode)
3. Alarm/Status
4. Inventory
00. Menu
Select item No. : 3
(1ch )
PASOLINK Introduction
32
ALARMS
IF Input ALM
IF input level in the ODU below (approximately)63dBm.
STATUS INFORMATION
MUTE
ODU output mute on/off status
TX/RX Frequency CH
Channel number corresponding to the ODU
transmit/receiver frequency
IDU Alarms
Input loss 1 16
In the 2MB interface, loss of 2MB input signal
detected. Alarm indicated for each channel.
Channel Usage Error 1 -16 In the 2MB
interface,2MB channel# is to
Used and a signal is detected at the input
AIS RCVD 1-16
In the 2MB interface, AIS (all1) received from
MUX equipment or Back-to-back 2MB
connection. Alarm indicated for each
channel.
PASOLINK Introduction
33
ALARMS
WS output loss
In the optional WS interface card, Receive WS
signal not detected from the demodulator.
TX CLK loss
Loss of TX clock, in the 2 MB interface.
RX CLK loss
Loss of RX clock in the 2 MB interface.
FSYNC ALM
Loss of RX frame synchronization at the RX DPU.
HIGH BER ALM
When the receive BER is > 10-3
LOW BER ALM
When the receive BER is > 10-6
BER ALM
BER alarm point for inserting AIS. Alarm trigger
point can be selectable from (10-3, 10-4,
10-5 and 10-6)
MOD ALM
Modulator 850 MHz PLL oscillator loop unlock
condition.
DEM ALM
RX carrier not synchronized or lost.
OPR ALM
Communication error between ODU and IDU
ODU ALARMS
TX Power ALM
Transmitter output power decreased by 3 to 5 dB
RX Level ALM
Receive level below squelch level
APC1 ALM
ODU 1st local oscillator APC unlock alarm
APC2 ALM
ODU 2st local oscillator APC unlock alarm
PASOLINK Introduction
34
INVENTORY
Monitoring
1. Monitoring voltage
2. Monitoring voltage
(continuous mode)
3. Alarm/Status
4. Inventory
00. Menu
Select item No. : 3
No.1 ODU
Serial number
16352
Manufactured date
OCT/2005
Software version (ROM/RAM) (1.02/2.03)
Bit rate
17/34MB
RF band
13GHz High
Sub band
A
Start frequency
13020.500MHz
Shift frequency
266MHz
CH separation
1.750MHz
IDU
SW UNIT
Serial number
4023
Manufactured date
DEC/2005
Software version (ROM/RAM) (1.20/2.40)
Bit rate
2/4/8/16x2MB
Option module
PM CARD
Inventory 2/4
IDU
No.1 MD UNIT
Serial number
12650
Manufactured date
DEC/2005
Software version (ROM/RAM) (1.2/2.49)
No.2 MD UNIT
PASOLINK Introduction
35