SCOPE
1.
This Defence Standard (DEF STAN) 02179 defines the specific requirements for the design,
production and fitting out of Magazine, Detonator and Readyuse Magazine Lockers.
2.
Included in this Defence Standard at Annex E is the existing range of Magazine, Readyuse
Magazine and Detonator Lockers fitted on HM Surface Ships and Royal Fleet Auxiliaries
(RFA).
FOREWORD
Sponsorship
1.
This Defence Standard is sponsored by the Warship Support agency (WSA), Ministry of
Defence (MOD).
2.
Any user of this Standard either within MOD or in industry may propose an amendment to
it. Proposals for amendments that are not directly applicable to a particular contract are to
be made to the publishing authority identified on Page (i), and those directly applicable to a
particular contract are to be dealt with using contract procedures.
3.
4.
5.
Unless otherwise stated, reference in this Standard to approval, approved, authorized and
similar terms, means by the MOD in writing.
6.
Any significant amendments that may be made to this Standard at a later date will be indicated
by a vertical sideline. Deletions will be indicated by 000 appearing at the end of the line
interval.
7.
This standard has been reissued to reflect changes in Departmental Nomenclature due to the
MOD reorganization and the changes to technical requirements.
Conditions of Release
General
8.
This Defence Standard has been devised solely for the use of the MOD, and its contractors in
the execution of contracts for the MOD. To the extent permitted by law, the MOD hereby
excludes all liability whatsoever and howsoever arising (including but without limitation,
liability resulting from negligence) for any loss or damage however caused when the Standard
is used for any other purpose.
9.
This document is Crown Copyright and the information herein may be subject to Crown or
third party rights. It is not to be released, reproduced or published without written permission
of the MOD.
10.
The Crown reserves the right to amend or modify the contents of this Standard without
consulting or informing any holder.
This Standard is the property of the Crown. Unless otherwise authorized in writing by the
MOD must be returned on completion of the contract, or submission of the tender, in
connection with which it is issued.
12.
When this Standard is used in connection with a MOD tender or contract, the user is to ensure
that he is in possession of the appropriate version of each document, including related
documents, relevant to each particular tender or contract. Enquiries in this connection may
be made to the authority named in the tender or contract.
13.
When Defence Standards are incorporated into MOD contracts, users are responsible for their
correct application and for complying with contractual and other statutory requirements.
Compliance with a Defence Standard does not of itself confer immunity from legal obligations.
The Category of this Standard has been determined using the following criteria:
a.
b.
c.
Related Documents
15.
In the tender and procurement processes the related documents listed in each section and
Annex A can be obtained as follows:
a.
British Standards
b.
Defence Standards
c.
Other documents
16.
All applications to the MOD for related documents are to quote the relevant MOD Invitation
to Tender or Contract number and date, together with the sponsoring Directorate and the
Tender or Contract Sponsor.
17.
Prime Contractors are responsible for supplying their subcontractors with relevant
documentation, including specifications, standards and drawings.
This Defence Standard may call for the use of processes, substances and/or procedures that
are injurious to health if adequate precautions are not taken. It refers only to technical
suitability and in no way absolves either the supplier or the user from statutory obligations
relating to health and safety at any stage of manufacture or use. Where attention is drawn to
hazards, those quoted may not necessarily be exhaustive.
19.
This Standard has been written and is to be used taking into account the policy stipulated in
JSP 430: MOD Ship Safety Management System Handbook.
Additional Information
20.
CONTENTS
Page No
SCOPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FOREWORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sponsorship . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Conditions of Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Categories of Naval Defence Standard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Related Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Health and Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Additional Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CONTENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2
3
3
3
4
4
4
4
5
SECTION
1.
1.1
1.2
PERFORMANCE SPECIFICATION . . . . . . . . . . . . . . . 8
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Environmental Conditions . . . . . . . . . . . . . . . . . . . . . . . . 8
SECTION
2.
NATIONAL/INTERNATIONAL REGULATIONS . . . . 8
SECTION
3.
3.1
3.1.1
3.1.2
3.1.3
3.1.4
3.1.5
3.1.6
3.1.7
3.1.8
3.1.9
3.1.10
3.1.11
3.1.11.1
3.1.11.2
3.1.11.3
3.1.12
3.1.12.1
3.1.12.2
3.1.12.3
3.1.12.4
3.1.13
3.1.14
3.1.15
3.1.16
3.1.17
3.1.18
3.1.19
3.1.20
3.1.21
3.1.22
3.1.23
3.1.24
MILITARY STANDARDS/REQUIREMENTS . . . . . . . .
General Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Distortion/Racking (due to flooding) . . . . . . . . . . . . . . . .
Base/Legs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Shock (Non-Contact Underwater Explosion) . . . . . . . . .
Electrical Screening . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Response to Attack on Ammunition . . . . . . . . . . . . . . . . .
Insulation/Cladding Plates . . . . . . . . . . . . . . . . . . . . . . . .
Radar Cross Section (Radar Echo Area) . . . . . . . . . . . . .
Radar Absorbent Material . . . . . . . . . . . . . . . . . . . . . . . .
Welding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Galvanizing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Painting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Surface Coatings for Detonator Lockers only . . . . . . . . .
External Coatings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Internal Coatings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Locker Doors and Lids . . . . . . . . . . . . . . . . . . . . . . . . . . .
Door Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Hinges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Locking Arrangements . . . . . . . . . . . . . . . . . . . . . . . . . . .
Clips and Closing Arrangements . . . . . . . . . . . . . . . . . . .
Flooding Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Drainage Arrangements . . . . . . . . . . . . . . . . . . . . . . . . . .
Venting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Interchangeability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stowage Arrangements . . . . . . . . . . . . . . . . . . . . . . . . . . .
Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Representative Inert Rounds/Ammunition Boxes . . . . . .
Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maximum/Minimum Thermometer Bracket . . . . . . . . .
Temperature Card Holder . . . . . . . . . . . . . . . . . . . . . . . . .
Magazine Designed Capacity List S285K . . . . . . . . . . .
5
8
8
8
9
9
9
9
2
10
10
10
10
10
10
10
10
11
11
11
11
11
11
11
12
12
12
12
12
12
12
12
12
13
Page No
3.1.25
3.1.26
3.1.27
3.1.28
3.1.28.1
3.1.28.2
3.2
Noticeboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tally/Marker Plates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Warning Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Detonator Lockers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Deck Mounted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Bulkhead Mounted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Test and Trials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
13
13
13
13
13
13
13
SECTION
4.
4.1
4.2
4.3
4.3.1
4.3.2
4.3.3
DESIGN REQUIREMENTS/GUIDANCE . . . . . . . . . . .
Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Composite Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
General Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Locker Carcass . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Locker Coatings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
14
14
14
14
14
15
15
SECTION
5.
ANNEX A
RELATED DOCUMENTS . . . . . . . . . . . . . . . . . . . . . . . . 16
ANNEX B
ANNEX C
ANNEX D
ANNEX E
Table E.1
Table E.2
Table E.3
Figure E.1
Figure E.2
Figure E.3
Figure E.4
Figure E.5
Figure E.6
Figure E.7
Figure E.8
Figure E.9
Figure E.10
Figure E.11
Figure E12a
Figure E12B
Figure E.12
Figure E.13
21
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
35
36
37
41
42
43
44
45
46
47
48
ALPHABETICAL INDEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
1.
PERFORMANCE SPECIFICATION
Related Documents: DEF STAN 02-154; DEF STAN 08-123; see also Annex A.
1.1
1.2
General
a.
Prior to the design of a new locker, consideration should be given to either using
an existing locker, or stowage of the explosive store in an appropriate magazine.
b.
Environmental Conditions
a.
2.
Sea States - The locker shall withstand, without failure, the maximum
sea states the vessel will meet in its design role;
(2)
Green seas loading - The requirements of DEF STAN 02154 shall be met
in full;
(3)
(4)
(5)
(b)
NATIONAL/INTERNATIONAL REGULATIONS
(No relevant information included)
3.
MILITARY STANDARDS/REQUIREMENTS
Related Documents: BS EN ISO 1461; BS EN 12163; BS EN 12164; BS EN 12167;
BS 381c; DEF STAN 80-78; DEF STAN 80-125; DEF STAN 80-165;
DEF STAN 80-187;DEF STAN 02-183 Parts 1 and 2; DEF STAN 02-706;
DEF STAN 02-723; DEF STAN 02-758; DEF STAN 02-759; BR 862; BR 8470; see also
Annex A.
3.1
General Requirements
3.1.1
Magazine Lockers shall be capable of withstanding full flooding from the Ship's
firemain and maintain watertightness and structural integrity.
3.1.2
Base/Legs
a.
3.1.3
3.1.4
All lockers shall be designed to remain captive and not become a hazard, after
experiencing shock up to 70 per cent of the maximum ship shock level.
b.
Explosive stores contained within Magazine Lockers shall remain safe and
serviceable after experiencing noncontact underwater explosion up to 70 per
cent of the maximum ship shock level.
c.
Explosive stores contained within RU Magazine Lockers shall remain safe after
experiencing noncontact underwater explosion up to 70 per cent of the
maximum ship shock level.
d.
A figure of 70 per cent of the maximum ship shock level equates to a hull shock
factor of 0.91 for Destroyers and Frigates and of 1.2 for larger ships. Actual
shock levels are derived by factoring the appropriate Grade Curve in BR 8470,
normally Grade 1987D.
e.
For lockers limited to a specific ship class, the Warship Project Manager (WPM),
shall be consulted to ensure that the shock levels in Clause 3.1.3d. are
appropriate.
Electrical Screening
a.
3.1.5
The need for Electromagnetic Pulse (EMP) and Radio Frequency (RF)
screening shall be evaluated when designing new or replacement Magazine and
RU Magazine Lockers.
3.1.6
Free standing lockers shall be provided with their own legs or base units
(between 100 mm to 150 mm high). The legs shall be strong enough to take the
full weight of the locker when full and to be capable of being bolted directly on to
Ship's seatings. Considerations shall be given to methods that overcome any
possible distortion of the locker due to the forces caused by deck movement in a
seaway being transmitted through the hold down bolts at the deck seating.
Insulation/Cladding Plates
a.
All Magazine and RU Magazine Lockers (excluding Detonator Lockers) that are
exposed to direct sunlight (i.e. Upper Deck Lockers) shall be insulated
internally to prevent condensation. All lockers manufactured from metallic
materials and exposed to direct sunlight shall also be fitted with external solar
cladding plates over the top and sides. Lockers sited close to a bulkhead do not
require cladding plates on the side adjacent to the bulkhead.
b.
The internal insulation shall be made from 19 mm thick Phenolic Foam. It shall
be secured by adhesive bonding or studding on all faces, excluding the base.
(A suitable insulation is available from MOD under NS No 0414/9679594).
c.
When fitted, the Solar Cladding plates shall stand off by 25 mm from the top
and sides of the locker to allow a free passage of cooling air. (See Clause 4.3.1a.).
3.1.7
3.1.8
3.1.9
Radar Absorbent Material (RAM) shall be used only when the RCS cannot be
reduced by shaping.
Welding
a.
3.1.10
All welding practice shall conform to the requirements of DEF STAN 02706.
Galvanizing
a.
All Mild Steel components shall be hot dip galvanized in accordance with the
requirements of BS EN ISO 1461.
3.1.11
Painting
3.1.11.1
3.1.11.2
a.
External and internal surfaces shall be suitably prepared and painted with two
coats of High Gloss Signal Red (BS 381C No 537) to DEF STAN 8078.
b.
External Coatings
a.
3.1.11.3
Unless stated on the relevant locker SDN then the following shall apply:
(1)
(2)
Internal Coatings
a.
Unless stated on the relevant locker SDN then the inside of all lockers
(excluding the wood battens) shall be prepared in accordance with the
requirements of DEF STAN 02759 and painted with two coats of Fire
Retardant white paint in accordance with the requirements of
DEF STAN 8078. One coat of white emulsion to DEF STAN 80125 shall be
applied to insulation prior to two coats of fire retardant white. For Composite
Materials see Clause 4.3.3a.
10
3.1.12
3.1.12.1
3.1.13
(2)
(3)
Locker door seals shall be capable of making the doors/lids watertight without
degradation from environmental conditions; additionally they shall be readily
replaceable.
The material and number of hinges required by each locker type shall be
dictated by the design requirements. The hinge pin shall be of the floating type
`peened and clenched' over at each end to prevent the pin from being removed.
Locking Arrangements
a.
3.1.12.4
Hinges
a.
3.1.12.3
(1)
Door Seals
a.
3.1.12.2
The locking arrangements for all lockers provided shall be in accordance with
the requirements of DEF STAN 02183 Part 1 or Part 2, as applicable.
b.
The clips are not to be able to rotate freely or spring open under the influence of
vessel motion, vibration or shock.
c.
Flooding Connection
a.
All magazine lockers shall be provided with one in number 1inch BSP female
connection in accordance with SDN 002 609 576. The connection (shall be
linked to the firemain or other locker flooding source as required) shall be sited
below the venting arrangements when the vent is sited in any position other
than the top of the locker.
NOTE Detonator lockers are not to be floodable.
3.1.14
Drainage Arrangements
a.
Magazine lockers shall be fitted with a minimum of two in number M12 or M20
brass drain plugs (brass type CZ 112 complying with BS EN 12163,
BS EN 12164 or BS EN 12167 as applicable). The drain plugs shall be sited at
the front of the locker.
b.
Readyuse lockers shall be fitted with two drain holes sited at the front of the
lockers. The holes shall be fitted with antisabotage arrangements, consisting
of a grille on the underside and a `Tophat' on the inside of the locker. On small
RU Lockers, antisabotage arrangements may be dispensed with due to space
restrictions.
11
3.1.15
Venting
a.
3.1.16
Configuration
a.
3.1.17
3.1.22
Fittings
a.
b.
The use of wood shall be kept to a minimum. Only unpainted hardwood shall be
used, which shall be fireproofed and scrubbed clean.
c.
3.1.23
Where practicable, racks, sections and shelves within the locker shall be clearly
marked for instant recognition. Each item shall be provided with adequate
supports and restraints, consistent with rapid removal.
3.1.21
Identification
a.
3.1.20
Lockers built to the same size and design shall be interchangeable on vessels'
seatings without modification.
Stowage Arrangements
a.
3.1.19
Interchangeability
a.
3.1.18
Magazine lockers shall be fitted with a suitable hook or bracket within the
locker to hold a maximum/minimum thermometer (NS No 0253/5229203).
A temperature card holder fabricated from 1.6 mm thick Aluminium Alloy shall
be fixed in a prominent position on the inside of the magazine locker, sized to
take an S285C record card (210 mm wide x 130 mm high). When these
dimensions cannot be achieved the largest board possible shall be provided.
12
3.1.24
3.1.25
A holder with a perspex cover shall be provided for the A4size `Magazine
Designed Capacity List', and fixed on the inside of the door.
Noticeboard
a.
3.1.26
Tally/Marker Plates
a.
3.1.27
All lockers shall be identified by fitting a marker plate (in accordance with the
requirements of DEF STAN 02723) indicating the manufacturer's name, date
of manufacture and Naval Store Catalogue Number (NS Cat No). The plate,
shall be fabricated in accordance with the requirements of SDN 003 545 289 (or
MOD approved equivalent) and shall be sited within the locker in a prominent
position.
Warning Notices
a.
3.1.28
Detonator Lockers
3.1.28.1
Deck Mounted
a.
3.1.28.2
Bulkhead Mounted
a.
3.2
The following tests shall be carried out on selected lockers as defined in the
contract action:
(1)
Magazine Lockers, minus their contents and with their doors/lids clipped
and locked shall be capable of holding a predetermined static head of fresh
water (defined in the contract);
(2)
13
(4)
(5)
4.
DESIGN REQUIREMENTS/GUIDANCE
Related Documents: DEF STAN 02167; BR 862; see also Annex A.
4.1
4.2
4.3
4.3.1
Construction
a.
All Magazine Lockers shall be designed to be capable of being used for readyuse
stowage of explosive stores with the minimum of conversion.
b.
The criteria detailed in this standard shall be considered in the design tof a new
locker. Additionally the requirements of the applicable parts of BR 862 shall be
met in full.
Material
a.
b.
The material type and thickness shall be such that the mass of the locker is kept
to a minimum, consistent with adequate strength. The effect of a saltladen
atmosphere and the range of solid and chemical constituents in salt water shall
be taken into account.
Composite Material
a.
Consideration shall be given to the use of materials which will preclude the
necessity for the physical shaping of lockers to reduce RCS. (See also Clauses
3.1.8a., 3.1.9a. and Section 3).
b.
General Construction
a.
The use of composite materials in the locker carcass obviates the requirement
for solar cladding.
b.
The use of a polyester laminating resin system in accordance with DEF STAN
02 167 shall be employed.
c.
Where required, a linear PVC thermoplastic foam shall be used as the core
insulation material in composite lockers.
d.
14
4.3.2
4.3.3
Locker Carcass
a.
b.
The carcass shall be constructed by first laying in the external skin of the locker
and curing it.
c.
Locker Coatings
a.
5.
(2)
15
BS EN 12163
BS EN 12164
BS EN 12167
Copper and copper alloys. Profiles and rectangular bar for general
purposes
BS 381C
JSP 430
DEF STAN 80125 Paint Finishing Emulsion For Canvas Type: Brushing
DEF STAN 80165 Paint System for Ships' Weatherwork, High Durability, Light
Weatherwork Grey, Type: Brushing
DEF STAN 80187 Paint System for Ships' Weatherwork
BR 862
Armament Stores:
Part 1:
Naval Magazine and Explosives Regulations
HM Surface Ships
Part 2:
Naval Magazine and Explosives Regulations Submarines
Part 3:
Naval Magazine and Explosives Regulations
BR 8470
16
JATO Locker
Demolition Charges
Over Centre Steel Clip (Drawings 003 503 128 to 003 503 141 inclusive)
Locking Hasps and Staple (Steel) (Drawings 003 503 142 to 003 503 144
inclusive)
Cladding Fastener (Steel) (Drawings 003 503 145 to 003 503 146
inclusive)
Hinge (Steel) (Drawings 003 503 147 to 003 503 149 inclusive)
Air Vent
17
VSP 167 155 03 Sea Gnat Magazine Horizontal Lockers Type 23 (Port and Starboard)
VSP 191
DG Ships/
XC1/
102/NC910(15)
American
Locker Ammunition, Readyuse
Origin Drawing
No. 5177578
ANNEX B.
B.
ABBREVIATIONS AND DEFINITIONS
B1.
For the purpose of this Standard the following abbreviations and definitions apply.
CMS
BR
Book of Reference
BS
British Standard
BS EN
BSP
D/S
Data Sheet
DEF STAN
Defence Standard
EMP
Electromagnetic Pulse
GRP
ISO
MAG
Magazine
MOD
Ministry of Defence
NATO
NES
NS
Naval Stores
NSN
PVC
Polyvinyl Chloride
QAWT
RAM
RATTAM
RCS
RF
Radio Frequency
18
B2.
RU
Readyuse
SDN
UN
United Nations
WPM
Locker
Magazine Locker
ANNEX C.
C.
PROCUREMENT CHECK LIST
C1.
ANNEX D.
D.
CHECK LIST FOR A NEW/REFURBISHED MAGAZINE LOCKER OR READY-USE
MAGAZINE LOCKER
D1. This Check List is not intended to be an exhaustive list of items but an aid in making up a more
comprehensive check list if necessary.
a.
19
Yes
No
20
The locker has been painted and the colours are as specified. The
paint is in good condition and is free from serious defects.
The inside of the locker has been checked for completeness and is
free from foreign objects and defects.
ANNEX E.
E.
CURRENT RANGE OF AMMUNITION AND DETONATOR LOCKERS
E1.
The following Tables and Figures show the existing range of Magazine and RU Lockers; they
are included for completeness.
Description
Material
Steel
Steel
Cladding Fastener
Steel/Alloy
Hinge
Steel
Steel
Air Vent
Aluminium Alloy
Stainless Steel
NSN 0262/4340892
Brass
Brass
Brass
NSN 0262/4233434
2 Padlock
Steel
21
22
Overall External
Size (mm)
641
362
749
625
673
356
95
978
626
984
4 Magazines
724
20 mm (CMS)
4 Magazines
20 mm Ammunition
F219/0287994559745
F219/0287994559746
F219/0287994559747
SDN
Locker
Contents
F219/0287994559706
2 Boxes C40
F219/0287994559717
40/60 Ammunition
984
F219/0287994559721
4 Charges
F219/0287994559725
F219/0287994559732
40/60 (CMS)
F219/0287994559716
20 mm Amunition (Oerlikon)
F219/0287994559731
F219/0287994559718
F219/0287994559741
Material
Fig
No
-
1048
635
845
371
432
115
356
673
1029
115
340
625
673
1048
635
845
429
629
775
439
800
724
429
629
775
439
800
4 Boxes H33
1181
533
813
318
304
406
322
310
412
Detonators
483
673
432
520
700
746
Detonators
483
673
651
520
700
965
Various
845
756
699
864
762
915
F219/0287994559748
Various
845
756
699
864
762
915
F219/0287994559740
60 Fitted Charges
724
502
229
769
520
390
F219/0287994559742
4 x W18 Boxes
895
700
600
1005
741
810
Aluminium Alloy
y
Aluminium Alloy
y
Mild Steel
Aluminium Alloy
y
Aluminium Alloy
Response
p
Force Ready-use
y
Locker
10 x SA80 Magazines
4
5
6
3 x 9 mm Pistols
003 546 866
5 x SA80 Rifles
7125993528053
as required
q
6 x 9 mm Magazines
2 x Ancillary Radios
690
355
1400 Composite
p
ANNEX E.
Usable Internal
Size (mm)
NSN
NSN
SDN
Locker
Contents
Overall External
Size (mm)
Material
Fig.
No
W
900
1140
1355
954
712
457
457
890
1200
D
600
790
630
865
432
788
788
606
826
H
900
900
1060
775
962
1118
1118
480
1030
Al Alloy
Al Alloy
Al Alloy
Al Alloy
Al Alloy
Al Alloy
Al Alloy
Al Alloy
Al alloy
7
8
9
10
11
12
12
13
14
2 x N36 Containers
Mk II Mod 3 Fuzes
1320
262
510
590
272
290
1364
325
624
610
519
756
Mild Steel
Mild Steel
15
16
Mk II Mod 3 Fuzes
274
570
300
385
670
816
Mild Steel
17
1678
654
630
1815
810
855
Al Alloy
18
12 MSS
545
190
161
610
206
168
Al Alloy
19
8 x M548 Boxes
20 Rounds Sea Gnat/SRBOC
1185
540
795
Not Applicable
1385
1302
720
1040
1080
2170
Al Alloy
Al Alloy
20
21
Al Alloy
VSP 191
003 365 075
American Origin
5177578
Not Applicable
1205 1000
850
Not Applicable
1064
1500
940
1030
1150
1423
2170
1130
1550
Al Alloy
Al Alloy
Al Alloy
22
23
24
550
560
1625
Al Alloy
0581/2090995456991
Not Codified
Not Codified
23
F219/99-721 7414
F219/996654127
F219/994102778
Not Codified
0606/1055997600570
Not Codified
4 Drums (Magazine)
6 x N17 Boxes
4 x H33 Boxes
Various
2 x C40 Boxes
12 Motors
27 Flares
60 Charges
8 x C238 Boxes (B MARC).
12 x M548 Boxes (PHALANX)
ANNEX E.
W
D
H
730
434
615
945
615
605
1205
540
736
844
755
700
542
262
674
Not applicable
Not Applicable
720
496
220
1056
672
770
F219/0287995450838
F219/0287995450839
F219/0287995450840
F219/0287995450841
F219/0287995450842
F219/0287995450843
F219/0287995450844
F219/0287995450845
F219/2090997355937
PLAN OF TRAY
DRAIN HOLE
CL OF CLIP
CL OF HINGE
CL OF LOCKING ARRANGEMENT
PLAN OF BASE
General Information
Material
Locker
Locker Material
Locker Type
Readyuse
Internal Furniture
Material
NS Cat No
F219/0287994559716
F219/0287994559731
Protection
Drawing
External Cladding
N/A
Internal Insulation
Flooding
Ventilation
Contents
Contents
4 in no Magazines
W
D
H
724 x 429 x 629
External
Dimensions mm
W
D
H
775 x 439 x 800
Weight Full
Weight Empty
Overall Size
286 kg
24
General Information
Material
Locker
Detonator Locker
Locker Material
Locker Type
Internal Furniture
Material
Hardwood Battens
NS CAT No
F219/0287-99-455-9741
Drawing
Protection
Contents
Contents (Boxes)
2 x D6:
2 x N33:
W
D
H
12.5 x 12.0 x 16.0
Battens
Removed
External
Dimensions
W
D
H
12.7 x 12.2 x 16.2
Overall Size
Weight Full
Weight Empty
External Cladding
Not Applicable
Internal Insulation
Not Applicable
Flooding
Not Applicable
Ventilation
Not Applicable
25
General Information
Material
Locker
Detonator Locker(s)
Locker Material
Mild Steel
Locker Type
Free Standing
Internal Furniture
Material
Hardwood
NS Cat No
F219/0290-99-455-9745 4 Box
F219/2090-99-455-9746 6 Box
Protection
Drawing
External Cladding
Not Applicable
Internal Insulation
Not Applicable
Flooding
Not Applicable
Ventilation
Not Applicable
Contents
Contents
W
483
D
673
H
432
W
483
D
673
H
651
External
Dimensions mm
W
520
D
700
H
746
W
520
D
700
H
965
Weight Full
Weight Empty
26
Battens
Panels
AIR VENT
DRAIN
FRONT ELEVATION (SECTIONAL)
General Information
Material
Locker
Pyrotechnic Locker
Locker Material
Locker Type
Internal Furniture
Material
Hardwood Battens
NS Cat No
F219/2090-99-455-9747
F219/2090-99-455-9748
Protection
Drawing
External Cladding
Contents
Contents
Internal Insulation
Pyrotechnics (Various)
W
D
H
845 x 756 x 699
External
Dimensions mm
W
D
H
864 x 762 x 915
Weight Full
Weight Empty
Not Applicable
Flooding
Special Arrangement
Ventilation
Overall Size
82 kg
27
Not Applicable
General Information
Material
Locker
Smoke Marker
Locker Material
Locker Type
Ready use
Internal Furniture
Material
Hardwood Battens
NS Cat No
F219/2090-99-455-9742
Drawing
Protection
External Cladding
Not Applicable
Contents
Internal Insulation
Not Applicable
Contents
Flooding
Not Applicable
Ventilation
Not Applicable
Internal
Dimensions mm
W
D
H
895 x 700 x 600
Battens
Removed
External
Dimensions mm
W
D
H
1005 x 741 x 810
Overall Size
Weight Full
Weight Empty
28
General Information
Material
Locker
Locker Material
Composite Material
Locker Type
Readyuse
Internal Furniture
Material
Composite Material
NS Cat No
F219/7125-99-352-8053
Protection
Drawing
External Cladding
Not Applicable
Contents
Contents
Internal Insulation
Not Applicable
5 x SA80 Rifles
Flooding
Not Applicable
3 x 9 mm Pistols
Ventilation
Not Applicable
10 x SA80 Magazines
6 x 9 mm Magazines
2 x Ancillary Radios
Not Applicable
Usable Space
W
D
H
690 x 355 x 1400
Overall Size
Unknown
95 kg
29
General Information
Material
Locker
Locker Material
Locker Type
Internal Furniture
Material
NS Cat No
F219/8140-99-545-0838
Protection
Drawing
External Cladding
Internal Insulation
Contents
Contents
W
D
H
730 x 434 x 615
Usable
Space
External
Dimensions mm
W
D
H
900 x 600 x 900
Overall Size
Weight Full
Weight Empty
Flooding
Not Applicable
Ventilation
Not Applicable
196 kg
85.3 kg (Estimated)
General Information
Material
Locker
Locker Material
Locker Type
Free Standing
Internal Furniture
Material
Hardwood Battens
NS Cat No
F219/8040-99-545-0839
Protection
Drawing
External Cladding
Internal Insulation
Contents
Contents
6 x N17 Boxes
W
D
H
945 x 615 x 605
Usable
Space
External
Dimensions mm
W
D
H
1140 x 790 x 900
Overall Size
Weight Full
Weight Empty
Flooding
Not Applicable
Ventilation
Not Applicable
31
General Information
Material
Locker
Locker Material
Locker Type
Internal Furniture
Material
NS Cat No
F219/8140-99-545-0840
Protection
Drawing
External Cladding
Internal Insulation
Contents
Contents
W
D
H
1205 x 540 x 368(2)
External
Dimensions mm
W
D
H
1355 x 630 x 1060
Weight Full
Weight Empty
Flooding
Not Applicable
Ventilation
Not Applicable
Usable
Space
Overall Size
32
General Information
Material
Locker
Pyrotechnic Locker
Locker Material
Locker Type
Magazine: Watertight
Cladded/Insulated
Internal Furniture
Material
Hardwood Battens
NS Cat No
F219/8140-99-545-0841
Protection
Drawing
External Cladding
Internal Insulation
Flooding
Ventilation
Contents
Contents
Pyrotechnics (Various)
W
D
H
844 x 755 x 700
Usable
Space
External
Dimensions mm
W
D
H
954 x 865 x 775
Overall Size
Weight Full
Weight Empty
Variable
81.6 kg (estimated)
33
General Information
Material
Locker
Locker Material
Locker Type
Internal Furniture
Material
Hardwood Battens
NS Cat No
F219/8140995450842
Protection
Drawing
External Cladding
Internal Insulation
Contents
Contents
W
D
H
542 x 262 x 674
Usable
Space
External
Dimensions mm
W
D
H
712 x 432 x 962
Overall Size
Weight Full
Weight Empty
Flooding
Not Applicable
Ventilation
Not Applicable
126.5 kg
77.5 kg (estimated)
34
FRONT ELEVATION
SIDE ELEVATION
FLOODING
CONNECTION
AIR VENT
CL OF CLIP
CL OF HINGE
CL OF LOCKING
ARRANGEMENT
DRAIN PLUG
FLOODING
CONNECTION
AIR VENT
CL OF CLIP
CL OF HINGE
CL OF LOCKING
ARRANGEMENT
DRAIN PLUG
35
General Information
Material
Locker
Locker Material
Locker Type
Readyuse
Internal Furniture
Material
NS Cat No
Motor
Flare
Drawing
Motor
SDN 003 547 250
Flare
SDN 000 872 157
or DGS D183b/0013
F219/0287995450843
F219/0287995450844
Protection
Contents
Contents
Motor
Flare
12 Motors
27 Flares
External Cladding
Not Applicable
Internal Insulation
Not Applicable
Flooding
2 Hose Connection
Ventilation
Not Applicable
W
D
H
457 x 788 x 1118
Overall Size
465 kg
36
General Information
Material
Locker
Locker Material
Locker Type
Internal Furniture
Material
NS Cat No
F219/8140-99-545-0845
Protection
Drawing
External Cladding
Internal Insulation
Contents
Contents
60 in no Charges SC 1LB MK N1
W
D
H
720 x 496 x 220
Including
Insulation
External
Dimensions
mm
W
D
H
890 x 606 x 780
Overall Size
Weight Full
Weight Empty
Flooding
Not Applicable
Ventilation
Not Applicable
58 kg
31 kg (estimated)
37
General Information
Material
Locker
30 mm BMARC/Phalanx
Locker Material
Locker Type
Internal Furniture
Material
Hardwood Battens
NS Cat No
F219/2090-735-5937
Protection
Drawing
External Cladding
Contents
Contents
W
D
H
1056 x 672 x 770
Usable
Space
External
Dimensions mm
W
D
H
1200 x 826 x 1030
Overall
Size
Weight Full
Weight Empty
Ventilation
188 kg (estimated)
38
General Information
Material
Locker
Locker Material
Locker Type
Watertight
Internal Furniture
Material
NS Cat No
F219/2090-99-545-6991
Protection
Drawing
External Cladding
Not Applicable
Internal Insulation
Not Applicable
Contents
2 in no N36 Containers 4.5 MK8 Misfired
Rounds
Contents
Flooding
Ventilation
W
D
H
1320 x 510 x 272
To inside of
rubber pad and
anchorage
External
Dimensions mm
W
D
H
1364 x 624 x 519
Including base,
stand and lid
Weight Full
Weight Empty
General Information
Material
Locker
Locker Material
Locker Type
Internal Furniture
Material
Hardwood Battens
NS Cat No
Not Codified
Protection
Drawing
DG SHIPS/XC1/102/NC910
External Cladding
Not Applicable
Internal Insulation
Not Applicable
Flooding
Not Applicable
Ventilation
Not Applicable
Contents
Contents
W
D
H
267 x 572 x 152
External
Dimensions mm
W
D
H
325 x 610 x 756
Primers
W
Overall Size
Weight Full
Weight Empty
Figure E.16 Free Standing Ready-use Locker for MK II MOD 3 Depth Charge Pistols and Primers
(magazines only)
40
General Information
Material
Locker
Locker Material
Locker Type
Internal Furniture
Material
Hardwood Battens
NS Cat No
Not Codified
Protection
Drawing
External Cladding
Internal Insulation
Contents
Contents (Boxes)
W
D
H
267 x 572 x 152
External
Dimensions mm
W
D
H
385 x 670 x 816
Weight Full
Weight Empty
Flooding
Not Applicable
Ventilation
Not Applicable
Overall Size
Figure E.17 Free Standing Ready-use Locker for MK II MOD 3 Depth Pistols and Primers
41
INSULATION
General Information
Material
Locker
Locker Material
Locker Type
Internal
Furniture
Material
NS Cat No
F219/997217414
Protection
Drawing
External Cladding
Internal
Insulation
Flooding
1 BSP Female
Ventilation
Contents
Contents
22 in no N4/N5 Rockets
W
D
H
1678 x 654 x 630
External
Dimensions mm
W
D
H
1815 x 810 x 855
Weight Full
Weight Empty
Usable Space
Overall Size
241 kg
General Information
Locker
Material
Marine Sound Signal
Locker Material
Locker Type
Readyuse
Internal Furniture
Material
NS Cat No
F219/2090-99-539-2053
Protection
Drawing
External Cladding
Not Applicable
Internal Insulation
Not Applicable
Flooding
Not Applicable
Ventilation
Not Applicable
Contents
Contents (Boxes)
W
D
H
545 x 190 x 161
Usable
Space
External
Dimensions mm
W
D
H
610 x 206 x 168
Overall
Size
Weight Full
Weight Empty
43
General Information
Material
Locker
20 mm BMARC `GAMBO'
Locker Material
Locker Type
Internal Furniture
Material
Hardwood Battens
NS Cat No
F219/2090-99-794-3516
Protection
Drawing
External Cladding
Contents
Contents
W
D
H
1185 x 540 x 795
Usable
Space
External
Dimensions mm
W
D
H
1385 x 720 x 1080
Overall
Size
Weight Full
Weight Empty
Flooding
Ventilation
44
General Information
Material
Locker
Locker Material
Locker Type
Internal Furniture
Material
NS Cat No
F219/8140-99-771-7212
Protection
Drawing
External Cladding
Contents
Contents (Boxes)
Flooding
Ventilation
Not Applicable
W
D
H
1302 x 1040 x 2170
Overall
Size
1124 kg (estimated)
487 kg
45
Side
CL of Clip
CL of Hinge
CL of Wedge Clip
CL of Locking Arrangements
Plan
General Information
Material
Locker
Locker Material
Locker Type
Internal Furniture
Material
NS Cat No
F219/GX-000-3645
Protection
Drawing
External Cladding
Contents
Contents
Ventilation
Not Applicable
W
D
H
1064 x 1203 x 2150
Overall
Size
830 kg (estimated)
320 kg
46
General Information
Material
Locker
JATO Locker
Locker Material
Locker Type
Internal Furniture
Material
Hardwood Battens
NS Cat No
Not Codified
Protection
Drawing
External Cladding
Contents
Contents
W
D
H
1205 x 1000 x 850
Usable
Space
External
Dimensions mm
W
D
H
1500 x 1150 x 1130
Overall
Size
Weight Full
Weight Empty
Flooding
Ventilation
47
General Information
Material
Locker
SRBOC
Locker Material
Locker Type
Internal Furniture
Material
NS Cat No
0606/1055-99-760-0570
Protection
Drawing
External Cladding
Contents
Contents (Boxes)
External
Dimensions mm
Aluminium Alloy
Aluminium Alloy
Flooding
Ventilation
Not Applicable
W
D
H
940 x 1423 x 1550
Weight Full
796 kg
Weight Empty
260 kg
Overall
Size
48
ALPHABETICAL INDEX
Fire characteristics: 12
Fittings: 12
Flooding connection: 11
Air vent: 11
Antisabotage arrangements: 11
Galvanizing: 10
Green seas loading: 8
Base/legs: 9
Hinges: 11
Identical lockers: 12
Identification: 12
Clips: 11
Insulation: 9, 14
Composite locker: 14
Configuration: 12
Contents board: 12
L
Locker: 19
Locker arrangements: 11
Locker carcass: 14
Locker coatings: 14
Detonator lockers: 13
Distortion/Racking: 8
Door seals: 11
Magazine locker: 19
Drain arrangements: 11
Material: 14
Drain holes: 11
Maximum/minimum thermometer: 12
Drain plugs: 11
N
Noticeboard: 12
E
Electrical screening: 9
Environmental conditions: 8
Painting: 10, 15
Pressure: 8
49
Shock: 9
QAWT arrangements: 11
Solar protection: 8
Solar radiation: 8
Stowage arrangements: 12
Structural: 8
Tally plate: 13
Thermometer: 12
Retaining arrangements: 10
V
S
Venting: 11
Salt corrosion: 8
Screening: 9
Screw threaded plugs: 11
Warning notices: 13
Sea states: 8
Weight of locker: 14
Seals: 11
Welding: 10
Self Colouring: 15
Wind effects: 8
50
DStan Helpdesk
Tel 0141 224 2531/2
Fax 0141 224 2503
Internet e-mail enquiries@dstan.mod.uk
File Reference
The DStan file reference relating to work on this standard is D/DStan/69/02/179.
Contract Requirements
When Defence Standards are incorporated into contracts users are responsible for their correct
application and for complying with contractual and statutory requirements. Compliance with a
Defence Standard does not in itself confer immunity from legal obligations.
Revision of Defence Standards
Defence Standards are revised as necessary by up issue or amendment. It is important that users of
Defence Standards should ascertain that they are in possession of the latest issue or amendment.
Information on all Defence Standards is contained in Def Stan 00-00 Standards for Defence Part 3 ,
Index of Standards for Defence Procurement Section 4 Index of Defence Standards and Defence
Specifications published annually and supplemented regularly by Standards in Defence News (SID
News). Any person who, when making use of a Defence Standard encounters an inaccuracy or
ambiguity is requested to notify the Directorate of Standardization (DStan) without delay in order
that the matter may be investigated and appropriate action taken.