Sei sulla pagina 1di 20

Technical Particulars for Erection & Maintenance work of Transm

S. No.

Particulars

Unit

Rate in Rs.

km

1612

Check survey as per approved route of line


includes re-checking of the line route as per
approved profile chainage, tower center
marking, bisection of angle tower as required
at site

3
a
b
c
d
e
f
4

Excavation excluding back filing, including


shoring, shuttering, dewatering etc. upto the
required depth as per foundation
specification/ drawings
Normal Soil(m3)
hard Soil
Soft rock/integrated rock
hard rock without blasting
hard rock with blasting
subermed hard/ normal at marine soil
Setting of template& stub/Anchor bolt

a
b
c
d

Setting of template& stub/Anchor bolt and


removal after concreting, excluding cost of
excavation and concreting but including back
filing with excavated/borrowed earth (with all
lead & lift) in layers in layers with ramming &
watering
132 kV S/C with +6m ext.
132 kV D/C with +6m ext.
220 kV S/C with +6m ext.
220 kV D/C with +6m ext.

nos.
nos.
nos.
nos.

Tangent
tower(A)
1427
1861
2068
2485

220 kV D/C Spl. Tower with +18m ext. ; span


upto550m

nos.

4152

f
5

221 kV D/C Spl. Tower with +18m ext. span


exceeding 550m
Concreting

nos.
(m3)

4152

a
b
c
d
6

Providing and laying cement concrete for all


types of foundation as per ISS 456 including
cement, sand, stone aggregate 20mm nominal
size , water etc. preparing surfaces,
shuttering, Mixng , placing , ramming , curing,
finishing as per specification & drawings
1:4:8 mix
1:3:6 mix
1:2:4 mix
1:1.5:3 mix
Steel Reinforcement (MT)

(m3)
(m3)
(m3)
(m3)
MT

6217
4748
4890
5965

cubic metre
144
305
337
770
706
209
Nos.

Cutting, bending, welding of joints if required,


fixing and placing of steel reinforcement as
per specification and drawings including
material
Earthing

42795

Earthing of towers with pipe type earthing


excluding the supply of pipes, wires, bolts &
connectors but excluding coke/charcoal etc.
augering & backfilling in all types of soil

set

1091

Earthing of tower legs with Counter poise


earthing excluding supply of materials but
including excavation and back filling in all
types of soil

each set by laying 4 wires each 15m long at a depth


of 600mm
set

1384

ii
8

each set by laying 4 wires each 25m long at a depth


of 600mm
set
Erection of towers(structures matrerials)

i
ii
iii
iv
v
a
b
c
d

Erection of super structures including Dshackles, ACD, Hangers, U-bolts, Step


bolts,danger plate, phase plate,etc. Also
including tack welding of bolts & nuts upto
bottom cross arm,/ beam level including
application of Zinc rich paint
132 kV S/C tower
132 kV D/C tower
220 kV S/C tower
220 kV D/C tower
220 kV D/C Spl. Tower with span upto550m
Normal Structure
with +4.5m extn to normal structure
with +9m extn to normal structure
with +18m extn to normal structure

vi
a
b
c
d

220 kV D/C Spl. Tower with span exceeding


550m
Normal Structure
with +4.5m extn to normal structure
with +9m extn to normal structure
with +18m extn to normal structure

Erection of 3mtr ext. including tack welding &


of bolts & nuts & application of Zn rich paint

132
132
220
220
10

kV
kV
kV
kV

S/C tower
D/C tower
S/C tower
D/C tower

Erection of 6mtr ext. including tuck welding of


bolts & nuts & application of Zn rich paint

2276

nos.
nos.
nos.
nos.

Tangent
tower(A)
5291
7343
7959
11590

nos.
nos.
nos.
nos.

26367
6237
12715
25943

nos.
nos.
nos.
nos.

34153
6173
12394
26152

nos.
nos.
nos.
nos.

Tangent
tower(A)
882
1123
1203
1603
Nos.

132
132
220
220

11

kV
kV
kV
kV

S/C tower
D/C tower
S/C tower
D/C tower

Erection of Sub-station structures (MT)


including levelling, setting of stub, tightening
& pucnhing of nut & bolts and tack welding
upto beam level asper specification

nos.
nos.
nos.
nos.

Tangent
tower(A)
1764
2164
2405
3046

MT

2950

12

13

a
b
c

Conductor Stringing

Stringing of ACSR Panther including hoisting


of insulator string, laying , jointing, &
tensioning of conductor, clamping with armour
rods, & fixing of vibration damper per route
km of line
3 conductor for S/C line
km
6 conductor for D/C line
km
Stringing of ACSR Zebra including hoisting of
insulator string, laying , jointing, & tensioning
of conductor, clamping with armour rods, &
fixing of vibration damper per route km of line
3 conductor for S/C line
6 conductor for D/C line
Stringing of ACSR Panther including hoisting
of insulator string, laying , jointing, &
tensioning of conductor, clamping with armour
rods, & fixing of vibration damper per route
km of line for river crossing section i.e from
Anchor tower to anchor tower for regular
flowing river only
3 conductor for S/C line
6 conductor for D/C line

km
km

29005
41192

km
km

28011
41896

Stringing of ACSR Zebra including hoisting of


insulator string, laying , jointing, & tensioning
of conductor, clamping with armour rods, &
fixing of vibration damper per route km of line
for river crossing section i.e from Anchor
tower to anchor tower for regular flowing river
only
3 conductor for S/C line
km
6 conductor for D/C line
km
Earth wire Stringing
Stringing of galvanised steel stranded wire
including laying, jointing, & tensioning,
clamping , clipping & fixing vibration damper
and earth bond etc.
1 Nos. for 7/3.15 mm galvanised wire
1Nos. for 7/4 mm galvanised wire
2 Nos. for 7/3.66 mm galvanised wire
Stringing of galvanised steel stranded wire
including laying, jointing, & tensioning,
clamping , clipping & fixing vibration damper
and earth bond etc. per route km of line for
river crossing section i.e from Anchor tower to
anchor tower for regular flowing river only

22079
32148

km
km
km

37344
53939

3737
4361
6542

Rs./km

a
b
c

1 Nos. for 7/3.15 mm galvanised wire


1Nos. for 7/4 mm galvanised wire
2 Nos. for 7/3.66 mm galvanised wire

km
km
km

4858
5676
5498

14

Dismantling of towers

a
b
c
d
e
15
a

Dismantling of super structures alonwith


extensions having tack welding of bolts & nuts
, including removing of D-shackles, hanger, Ubolts,step bolts, ACD, danger plate, phase
plate of tower including transportation from
site to our store and stacking of all materials,
number plate,
132 kV & 220 kV S/C & D/C towers (all types)
400 kV & S/C & D/C Towers (all types)
220 D/C spl. Tower
400kV S/C & D/C spl. Tower
SubStation Structures
Destringing of Earth wires/ Conductor
ACSR panther Conductor

MT

MT
MT
MT
MT
MT

Dismantling of vibration dampers & armour


rods, removal of conductor from clamps &
fittings in rollers , detensioning, dehoisting of
insulator string as required and collecting the
material and depositing the same in our store
and stacking
3 conductor for S/C line
km
6 conductor for D/C line
km
ACSR zebra conductor

Dismantling of vibration dampers & armour


rods, removal of conductor from clamps &
fittings in rollers , detensioning, dehoisting of
insulator string as required and collecting the
material and depositing the same in our store
and stacking
3 conductor for S/C line
km
6 conductor for D/C line
km
Earth wire

16
a

Dismantling of earth bonds,vibration dampers,


declipping & fitting in rollers ,detensioning,
and collecting the material and depositing the
same in our store and stacking
1 Nos. for 7/3.15 mm galvanised wire
km
1Nos. for 7/4 mm galvanised wire
km
2 Nos. for 7/3.66 mm galvanised wire
km
Restringing of Earth wires/ Conductor
ACSR panther Conductor

3255
3752
4570
5291
3255
Rs./km

24291
35371

31907
45312

4105
4794
7199
Rs./km

Dismantling of vibration dampers & armour


rods,fittings in rollers , detensioning, holding
& lowering of conductor , dehoisting of
insulator string as required, adding/ removing
& jointing of conductor, hoisting of insulator
string, lifting of conductor rollers, and
retensioning, jointing, fitting of vibration
dampers and armour rods, and clamping per
route km of line section to be restrung
dismantled material not reused to be
deposited in our store and stacked
3 conductor for S/C line
km
6 conductor for D/C line
km
ACSR zebra conductor

22079
32148

Dismantling of vibration dampers & armour


rods,fittings in rollers , detensioning, holding
& lowering of conductor , dehoisting of
insulator string as required, adding/ removing
& jointing of conductor, hoisting of insulator
string, lifting of conductor rollers, and
retensioning, jointing, fitting of vibration
dampers and armour rods, and clamping per
route km of line section to be restrung
dismantled material not reused to be
deposited in our store and stacked
3 conductor for S/C line
km
6 conductor for D/C line
km
Earth wire

17

Dismantling of earth bonds, vibration dampers


& declipping & fitting in rollers ,detensioning,
holding & lowering of earth wire , adding/
removing & jointing of earth wire, lifting of
rollers, and retensioning, jointing, clipping
,fitting of vibration dampers and earth bonds
per route km of line section to be restrung
dismantled material not reused to be
deposited in our store and stacked
1 Nos. for 7/3.15 mm galvanised wire
km
1Nos. for 7/4 mm galvanised wire
km
2 Nos. for 7/3.66 mm galvanised wire
km
Rivetment of Towers

29005
41192

3737
4361
6542

Providing and laying cement concrete


including curing, compaction etc.complet
using stone aggregate 40 mm nominal size
m3
( crusher broken) in foundation plinth, using 1
cement : 5 sand : 10 aggregate mix

1575

Random rubble stone masonry for rivetment in


1:5 cement sand mortar including providing
and fixing 100 mm dia PCC drain pipe & raised
and cut-pointing on stone masonry in 1:3
cement sand mortar excluding excavation but m3
back filing inside rivetment using excavated/
borrowed earth (with all lead & lift) in layers
not exceeding 20 cm in depth & considering
each deposited layer by ramming & watering

1508

Random rubble dry stone pitching including


preparing surface etc. complete with raised &
m3
cut pointing in cement sand mortar 1:3 curing
etc.

543

Cement concrete coping grade 1cement :2


coarse sand :4 graded stone aggregate )
rounding edges etc. but excluding the cost of
rasing of steps etc. complete for 75 mm thick
with 20mm thick nominal size aggregate

sq. metre

Brick masonry in foundation & plinth with


bricks of class designation 75 in cement
mortar ( 1cement : 5 coarse sand)

m3

Brick on edge flooring with bricks of class


designation 75 including poiniting in cement
Sq. metre
mortar( 1:3) complete laid on 12 mm thick bed
of cement sand mortar 1:5

18
a

19
a

Setting of stub anchor bolt & template


132 kV D/C narrow base towers
Tangent tower(A)
Small angle tower(B)
Medium angle Tower( C )
Erection of Towers
132 kV D/C narrow base towers
Tangent tower(A)
Small angle tower(B)
Medium angle Tower( C )

242

1939

248

Nos.
Nos.
Nos.

1725
2601
2794

Nos.
Nos.
Nos.

6136
13779
19419

ork of Transmission Lines

Small angle
tower(B)
1535
2597
2455
2902

Medium
angle
Tower( C )
2388
2806
2902
3528

Large
angle/dead
end(D)
2470
3014
3319
4152

Small angle
tower(B)
6222
10683
10150
17413

Medium
angle
Tower( C )
6639
12474
11693
18857

Large
angle/dead
end(D)
9332
17093
15232
25270

Small angle
tower(B)
1235
1571
1684
2918

Medium
angle
Tower( C )
1459
1861
1988
3688

Large
angle/dead
end(D)
1779
2261
2421
4875

Small angle
tower(B)
2325
2855
3175
4025

Medium
angle
Tower( C )
3014
3704
4105
5211

Large
angle/dead
end(D)
3511
4313
4794
6061