Sei sulla pagina 1di 30

Equipment Standards List

Equipment_Standard
ACB

Equipment_Name
AIR BREAKER

ACU

AIR CONDITIONING UNIT

ACU-CR
ACU-P

COMPUTER ROOM AIR


CONDITIONER
PORTABLE AIR CONDITIONER
UNIT

ACU-SU

AIR CONDITIONING SPLIT


UNIT

ACU-SUDM

DUCTLESS MINI SPLIT AIR


CONDITIONING

AED

AUTO EXTERNAL
DEFIBRILLATOR

AELT

AERIAL LIFT

AHU

AIR HANDLING UNIT

AHU-FA
AHU-MU

AHU FAN ASSEMBLY


MAKE UP AIR UNIT

AIRCOMP

AIR COMPRESSOR

AIRCOMP-PROCESS

PROCESS AIR COMPRESSOR

AIRD

AIR DRYER

ARCN

AIR CURTAIN

BAT-CHGR
BAT-ENGS
BAT-METS

BATTERY CHARGER
ENGINE START BATTERIES
BATTERY METERING SYSTEM

BFPR

BACKFLOW PREVENTER

BLER
BOILER
BOILER-GH

BUILD-EXT
BUILD-INT
BUILD-MS
BUILD-TR

BLEACHERS
BOILER
HEATING BOILER, GAS
BUILDING AUTOMATION
SYSTEM
BUILDING EXTERIOR
BUILDING INTERIOR
BUILDING MANAGEMENT SYSTEM
BUILDING TOURS - ROOF INSPECTIONS

CBSHLTR

CAMPUS BUS SHELTER

CDRM

CLOTHES DRYER MACHINE

CHIL

CHILLER

CHIL-C
CHIL-CP

CENTRIFUGAL CHILLER
CHILLER CONTROL PANEL

CHIL-DF

DRINKING FOUNTAIN WATER


CHILLER

CIRCUITBRK
CLASSRM

CIRCUIT BREAKER
CLASS ROOM

CLOS-EL

ELECTRICAL CLOSET

BUILD-AS

COMPRESS
CONCENTR

AIR COMPRESSOR
CONCENTRATOR

CONDENSER

CONDENSING UNIT

COOLER

COOLER

COOLTWR
COOLTWR-CCT
COOLTWR-CF
COPIER

COOLING TOWER
CLOSED COIL WET TYPE COOLING TOWER
CROSS FLOW COOLING TOWER
DEPARTMENTAL COPIER

CORU

CONVECTOR RADIATION
UNIT

CRANE-GNTY

GANTRY CRANE

CSER

CUSTOMER SERVICE

CU-WC

WATER COOLED
CONDENSING UNIT

CWAM

CLOTHES WASHER MACHINE

DAMP

DAMPER

DISP

DISPOSAL

DOOR

DOOR

DOOR-AUTO

AUTOMATIC DOOR

DOOR-EME

EMERGENCY EXIT DOOR

DOOR-EXT

EXTERIOR DOOR

DOOR-INT
DSHW

INTERIOR DOOR
DISHWASHER

DSTCTR

DUST COLLECTOR

DSW
DUCT-BUS

DISCONNECT SWITCH
BUS DUCT

EDCA

EDDY CURRENT ANALYSIS

ELEVATOR

ELEVATOR

ERV

ENERGY RECOVERY
VENTILATION

EXHAUST-FHD

FUME EXHAUST HOOD

EXHAUST-KITHD

KITCHEN EXHAUST HOOD

EXHAUST-VHD

EXHAUST VENTILATION HOOD

FAN-DEX

DISH WASHER EXHAUST FAN

FAN-EX

EXHAUST FAN

FAN-FSEX

FIRE SMOKE EXHAUST FAN

FAN-MOTR
FAN-OA

FAN MOTOR
OUTSIDE AIR FAN

FAN-PS

PRESSURIZED SUPPLY FAN

FAN-REL

RELIEF FAN

FAN-RET
FAN-SP
FAN-SP
FAN-TA

FCU
FDWRMR
FILT-HVAC
FILT-WTR
FIRE-AS
FIRE-EXT
FIRE-EXT-10-DRY
FIRE-EXT-20-CO2
FIRE-EXT-20-DRY
FIRE-MS
FIRE-SP
FIRE-SPR
FIRE-SS

RETURN FAN
SMOKE PURGE FAN
SUPPLY FAN
TRANSFER AIR FAN
VEHICLE EXHAUST
EXTRACTION FAN
FAN COIL UNIT
FOOD WARMER
FILTER HVAC
FILTER WATER
FIRE ALARM SYSTEM
FIRE EXTINGUISHER
FIRE EXTINGUISHER, #10 DRY CHEMICAL
FIRE EXTINGUISHER, #20 CO2
FIRE EXTINGUISHER, #20 DRY CHEMICAL
FIRE MIST SYSTEM
STAND PIPE SYSTEM
FIRE SPRINKLER SYSTEM
SPRINKLER SYSTEM

FIRE-SUP

FIRE SUPPRESSION SYSTEM

FKLT
FLMTR
FO-C
FO-P
FURNACE
GEN
GEN-CP
GEN-EMP
GEN-SW
GFP

FORKLIFT
FLOW METER
FUEL OIL CONTROLS
FUEL OIL PUMP
HOT AIR FURNACE
GENERATOR
GENERATOR CONTROL PANEL
EMERGENCY POWER GENERATOR
GENERATOR SWITCHGEAR
GROUND FAULT PROTECTION
ELECTRICAL SAFETY
GLOVES

FAN-VEXE

GLOVES-ELS

GMU

GLYCOL MAKE-UP UNIT

HEATEX

HEAT EXCHANGER

HEATR-CU
HEATR-D

CABINET UNIT HEATER


DUCT HEATER
DOMESTIC HOT WATER
HEATER
ELECTRIC UNIT HEATER

HEATR-DHW
HEATR-EU

HEATR-SP

SPACE HEATER

HEATR-STU

STEAM UNIT HEATER

HUMID

HUMIDIFIER

HVAC-OV

HVAC OUTLET VENT

HV-SW

HIGH VOLTAGE SWITCH

ICEM

ICE MACHINE

INCA

INSTRUMENT CALIBRATION

LGHT

LIGHTING

LGHT-EM

EMERGENCY LIGHT

LGHT-EMS

EMERGENCY EXIT LIGHT


SIGN

LGHTF-EM
LGHT-PL
LGHT-PP
LVTC

EMERGENCY LIGHTING FIXTURE


LIGHTING PARKING LOT
LIGHTING POWER PANEL
LOW VOLTAGE CABLE TESTING

MANH

MANHOLE

MAS
MCC
MECHRM
MOTOR-ES
MTS
MVC
MVS

MEDIUM VOLTAGE AIR SWITCH (ABOVE 600V)


MOTOR CONTROL CENTER
MECHANICAL ROOM
ELECTRIC MOTOR STARTER
MANUAL TRANSFER SWITCH
MEDIUM VOLTAGE CABLE TESTING
MEDIUM VOLTAGE SWITCH - METAL ENCLOSED

MZAH

MULTIZONE AIR HANDLING


UNIT

ODP

OUTPUT DISTRIBUTION PANEL

OHGD

OVERHEAD GARAGE DOOR

OVEN

OVEN

PAJK

PALLET JACK

PANEL-PA
PANEL-RP

PRE ACTION PANEL


REMOTE POWER PANEL

PAPR

PAYMENT APPROVAL
PROCESS

PAS
PBX-NR
PC

PRE ACTION SYSTEM


PBX MACHINE
DESKTOP COMPUTER

PDU

PHONE
PHX
PIV
PLOTTER
PQM
PRINTER
PS-EM

POWER DISTRIBUTION UNIT


PORTABLE FUME
COLLECTOR
LEXAR PHONE
PLATE AND FRAME HEAT EXCHANGER
POST INDICATING VALVE
PEN PLOTTER
POWER SYSTEM METERING DEVICE
COMPUTER PRINTER
EMERGENCY POWER MANAGEMENT SYSTEM

PUMP

PUMP

PUMP-A

AIR PUMP

PUMP-BF

BOILER FEED WATER PUMP

PFCR

PUMP-CHE
PUMP-CIR

CHEMICAL WATER
TREATMENT PUMP
CIRCULATING PUMP

PUMP-CRU

CONDENSATE RETURN PUMP


UNIT

PUMP-CW
PUMP-CW

CHILLED WATER PUMP


CONDENSER WATER PUMP

PUMP-D

DOMESTIC WATER PUMP

PUMP-FB
PUMP-FH
PUMP-FIRE
PUMP-FIREJ
PUMP-FUO

PUMP-HEAT
PUMP-HW
PUMP-MU

FIRE BOOSTER PUMP


FIRE HOUSE PUMP
FIRE PUMP
FIRE JOCKEY PUMP
FUEL OIL PUMP
GASOLINE DISPENSING
PUMP
HEAT PUMP
HOT WATER PUMP
MAKE UP WATER PUMP

PUMP-SUMP

SUMP PUMP

PUMP-GD

PUMP-WSH

WATER SOURCE HEAT PUMP

REFRIG

REFRIGERATION

REFRIG-GMS

REFRIGERANT GAS
MONITORING SYSTEM

ROOF

ROOF

RTU
SBD
SHREDDER
SHWR-EM
SMOKE-DET
STS
STW
SWITCH-AT
TANK-FUST

ROOF TOP UNIT


SWITCHBOARD
PAPER SHREDDER
EMERGENCY SHOWER
SMOKE DETECTOR
STATIC TRANSFER SWITCH
STAIRWAY
AUTOMATIC TRANSFER SWITCH
FUEL STORAGE TANK

TANK-HWS

HOT WATER STORAGE TANK

TELE-2LINE-A
TELE-4LINE-A

TYPE A PHONE W/TWO LINES


TYPE A PHONE W/FOUR LINES
EMERGENCY TELEPHONE
ELEVATOR

TELE-EME

TEST-100
TOWER-NCR

EMERGENCY TELEPHONE
VOICE
TEST STATION
NCR TOWER

TRANSFMR

ELECTRICAL TRANSFORMER

TRANSFMR-60
TRANSFMR-WT
TRNSFMR-DT
TRNSFMR-EL

60 HZ - 50 HZ TRANSFORMER
WET TYPE TRANSFORMER
DRY TYPE TRANSFORMER
ELECTRICAL TRANSFORMER

TELE-EMV

TSCS

TRAFFIC SIGNAL CONTROL


SYSTEM

TVS
UPS-BS
UPS-M
UPS-MB
UPS-PT
UPS-SW
USS
VAC-2000

TRANSIENT AND SURGE SUPPRESSION


UPS BATTERY STRING
UPS MODULE
UPS MAINTENANCE BYPASS
UPS SYSTEM PACKAGED TYPE
UPS SWITCHGEAR
UNIT SUBSTATION
STANDARD FLOOR VACUUM

VAV

VARIABLE AIR VOLUME

VEHICLE-CU

COMMERCIAL UNIT VEHICLE

VEHICLE-EL

ELECTRIC VEHICLE

VFD

VARIABLE FREQUENCY
DRIVE

VIBA

VIBRATION ANALYSIS

WFTN
WSEQ

WATER FOUNTAIN
WORKSHOP EQUIPMENT

Equipment_Description
Air Conditioning Unit - often referred to as AC, a self-contained unit with
evaporating and condensing coils packaged together. Not a split system.
Window
and
through-wall
unit Type.
Computer
Room
Air Conditioner
- or Data Center Cooling System is a unit
that monitors and maintains the temperature, air distribution and humidity
in a network room or data center.
Portable Air Conditioner Unit
Air Conditioning Split Unit (indoor Unit) - or Air Conditioning Split System,
Split System Air Conditioners this is referred to as indoor unit and
evaporator coil (air handler, heat pump, furnace or heater).
Ductless Mini Split Air Conditioning - The ductless split system has an
outside condensing unit, very similar to a regular split system air
conditioner. It also has an indoor unit. However, the indoor unit are not
ducted; they simply hang on a wall or mount in the ceiling (Cassette Unit).
They are much quieter than window units Some of the more common
brand
names
are Mitsubishi,
LG,- is
Sanyo,
Samsung,
Fujitsu,
andthat
etc.
Automatic
External
Defibrillator
a portable
electronic
device
automatically diagnoses the potentially life threatening cardiac
arrhythmias of ventricular fibrillation and ventricular tachycardia in a
patient, and is able to treat them through defibrillation, the application of
electrical therapy which stops the arrhythmia, allowing the heart to
reestablish
anMan
effective
rhythm.
Aerial lift - or
lift, Scissor
Lift, Bucket Truck
Air Handling Unit - An air handling unit, or air handler, is a device used to
condition and circulate air as part of a heating, ventilating, and airconditioning system. An air handling unit is usually a large metal box
containing a blower, heating or cooling elements filter racks or chambers,
and dampers. Air handling unit usually connect to a ductwork ventilation
system that distributes the conditioned air through the building and
returns it to the AHU. Sometimes AHUs discharge (supply) and admit
(return) air directly to and from the space served without ductwork.
Make-Up Air Unit - An air handler that conditions 100% outside air and no
recirculate
air. - May be for pneumatic controls, or process air of any
Air
Compressor
type. An air compressor is a device that converts power (usually from an
electric motor, a diesel engine or a gasoline engine) into kinetic energy by
compressing and pressurizing air, which, on command, can be released
in quick bursts. There are numerous methods of air compression, divided
into either positive-displacement or negative-displacement types. Air
compressors are commonly found in a wide range of industrial and
commercial facilities.
Air Dryer - Air dryer unit typically associated with air compressors. A
compressed air dryer is a device for removing water vapor from
compressed air. Compressed air dryers are commonly found in a wide
range of industrial and commercial facilities.

PM_Schedule

Air Curtain - are also known as air doors or fly fans or air screens. An air
curtain is a device used for separating two spaces from each other,
usually at the exterior entrance. The most common configuration for air
curtains is a downward-facing blower fan mounted over an opening,
blowing air across the surface of the opening. Air Curtains can come with,
or without heaters to heat the air. Normally the opening is an entrance to
a building, or opening between two space conditioned at difference
temperatures. Air curtains can serve many purposes. They can be
intended to help keep flying insects out by creating forceful turbulence. It
also helps keep out outside air, reducing infiltration though the opening.
They can also be used to avoid cold drafts by mixing in warm air heated
by the air curtain. The fan must be powerful enough to generate a jet of
air that can reach the floor.

Backflow Preventer - A backflow preventer is a check valve that prevents


water from flowing backwards into a water supply line resulting in a
contaminated water supply.
Bleachers
Boiler - It is part of an HVAC system.
Building Automation System - It is part of an HVAC system.

Building Exterior
Building Interior
EMENT SYSTEM
ROOF INSPECTIONS
Campus Bus Shelter - or Transit Shelter is a designated place where
buses stop for passengers to board or leave a bus.
Clothes Dryer Machine
Chiller - There are basically two types of chillers, they are water cooled
chiller and air cooled chiller. A chiller is a refrigeration apparatus that
produces cold water or water/glycol mix, to provide comfort cooling for
buildings. A chiller uses the evaporation of a refrigerant to cool the fluid
through a heat exchanger. The fluid through a piping system or circuit to
reach the air handling unit, fan coil unit/unit ventilator, chilled beam and
etc.

Drinking Fountain Water Chiller - Are also known as indoor process


chiller, remote chiller, remote water chiller. A drinking fountain water chiller
is a refrigeration apparatus that produces cold water to provide cool water
for drinking water fountain through a piping system.
Class Room
Electrical Closet - An electrical closet or electrical room is a room or
space in a building dedicated to electrical equipment. The size of the
electrical room is usually proportional to the size of the building. Large
buildings may have a main electrical room and subsidiary electrical
rooms. Electrical equipment may be for power distribution equipment, or
for communications equipment.

Condensing Unit (Outdoor Unit) or condenser unit, these condenser units


are located on the outside of the building. The condenser unit has electric
power supply and copper tubes one for vapor refrigerant entering and
another for liquid refrigerant leaving the unit that lead inside of the
building to air-conditioning split system unit, evaporator unit, refrigeration
unit walking cooler ice maker and etc.
Cooler - Unit used to keep things cool typically used by Food Services for
food products, Walk-in Cooler/Freezer, but could be some laboratory
coolers.

Cooling Tower
TYPE COOLING TOWER
OLING TOWER
Convector Radiation Unit - or Convection space heaters Steam / Hot
Water, without fans rely on the natural air circulation in a room to
distribute heat, rather than using a fan to direct the flow of hot air. As a
result, these heaters are generally quiet but slower at heating a room than
models with fans.
Gantry Crane - or Portable A-Frames & Trolley, A-Frame Lifting Gantry,
Hand Operated Chain Hoist.
Customer Service - Customer service is a series of activities designed to
enhance the level of customer satisfaction that is, the feeling that service
has met the customer expectation.
Water Cooled Condensing Unit
Clothes Washer Machine - or Washing Machine, Laundry Machine,
Clothes Washer, Washer.
Damper - Fire Damper, Smoke Damper, Ceiling Radiation Damper, Relief
Damper, etc.
Fire Damper: A device designed to impede the spread of fire through
walls, floors and partitions.
Ceiling Radiation Damper: A device designed to impede the spread of fire
through openings in ceiling membranes.
Smoke Damper: Is a piece of hardware that restricts smoke from traveling
into and throughout an HVAC system.
Disposal - or Garbage Disposal, Garbage Disposer, Food Waste
Disposal, Food Waste Disposer.
Door - A door is a movable structure used to open and close an entrance,
typically consisting of a panel that swings on hinges or that slides or spins
inside a space.
Automatic Door - Automatic doors are movable doors that close or open
automatically at a walkway and are normally used for entrances and exits.
There are different types of automatic doors. Some types of automatic
doors are activated when a person enter/leave because of sensors
included in the doors, or by hitting a button which results the doors to
open. These types of doors are used in industrial, factory operations.
Emergency Exit Door - in a structure is a special exit for emergencies
such as a fire.
Exterior Door

Interior Door
Dishwasher - Commercial or household.
Dust Collector - is a system used to enhance the quality of air released
from industrial and commercial processes by collecting dust and other
impurities from air or gas. Designed to handle high-volume dust loads, a
dust collector system consists of a blower, dust filter, a filter-cleaning
system, and a dust receptacle or dust removal system. It is distinguished
from air cleaners, which use disposable filters to remove dust.

Eddy Current Analysis - for chillers and boilers. Eddy current testing is a
nondestructive accurate method of analyzing the chillers and heat
exchanger tubes. It can be done quickly with minimal downtime. This type
of testing will identify common problems, which cause tube leaks that
result in major repair cost and extended downtime.
Elevator - Vertical transport equipment that moves people or goods
between floors.
Energy Recovery Ventilation - or heat recovery ventilator, pre-conditioning
unit is the energy recovery process of exchanging the energy contained in
normally exhausted building or space air and using it to treat
(precondition) the incoming outdoor ventilation air in HVAC systems.
During the warmer seasons, the system pre-cools and dehumidifies while
humidifying and pre-heating in the cooler seasons. The benefit of using
energy recovery is the ability to meet the ASHRAE ventilation & energy
standards, while improving indoor air quality and reducing total HVAC
equipment capacity.
Fume Exhaust Hood - or Fume Hood, Fume Cabinet, Fume cupboard,
Laboratory Chemical Fume Hood. There are basically two types of fume
hoods, they are: Ductless fume hoods are self-contained unit with fan and
HEPA and/or carbon filters. Ducted fume hoods system includes an
exhaust hood, exhaust fan and ductwork.
Kitchen Exhaust Hood - or Kitchen Hood, Commercial Kitchen Exhaust
Hood. It is part of an HVAC System/Kitchen Equipment. A typical kitchen
ventilation system includes an exhaust hood or canopy, ductwork,
exhaust fan, and (supply make-up air fan if applicable), both fans
exhausting and supplying air within the cooking area.

TION HOOD
Dish Washer Exhaust Fan
Exhaust Fan - is a fan which is used to control the interior environment by
venting out unwanted odors, particulates, smoke, moisture, and other
contaminants which may be present in the air. Exhaust fans can also be
integrated into a heating and cooling system. Common locations for
exhaust fans include bathrooms, kitchens, shops, and Mechanical rooms,
and etc.
Fire Smoke Exhaust Fan - It is part of a Fire Alarm System/HVAC system.

Pressurized Supply Fan - or stairway air supply pressurized smoke


blocking system.

Relief Fan - It is part of an HVAC system. On some systems, this relief air
is called exhaust air, but should not be confused with exhaust air that is
provided for the purpose of control of contaminates and compliance with
ventilation requirements.
Return Fan
Supply Fan

Vehicle Exhaust Extraction Fan or Automotive Exhaust Blower Fan, It is


part of Automotive Shop.
Fan Coil Unit/Unit Ventilator
Food Warmer - code used by Auxiliary services or others
HVAC Air Filter
Water Filter System
Fire Alarm System
Fire Extinguisher
ER, #10 DRY CHEMICAL
ER, #20 CO2
ER, #20 DRY CHEMICAL

Fire Sprinkler System


Fire Suppression System - are used in conjunction with smoke detectors
and fire alarm systems to improve and increase public safety.
Forklift
CSI # 41 62 23 Forklift Trucks
Water Flow Meter

Hot Air Furnace


Electric Generator

TROL PANEL
ER GENERATOR

ROTECTION
Electrical Safety Gloves (ELSG)
Glycol Make-up Unit or Glycol/Water Make-Up Glycol Make-Up, Package
glycol make-up system, are designed to maintain minimum system
pressure levels. The systems are completely automatic and operate as
needed to add water or water-glycol solution to a closed loop heating,
chilled water, snowmelt, or radiant heat system and etc.
Heat Exchanger - It is part of an HVAC system. A heat exchanger is a
piece of equipment built for efficient heat transfer from one matter to
another.
Cabinet Unit Heater
Domestic Hot Water Heater

Space Heater - is self-contained equipment for heating an enclosed area.


Humidifier - It is part of an HVAC system. A humidifier intervenes with
heating or cooling system and improves indoor moisture levels so that
can be comfortable and healthy working environment.
HVAC Outlet Vent
High Voltage Switch - or High Voltage Switchgear, a switchgear is used
both to de-energize equipment to allow work to be done and to clear
faults downstream.
Ice Machine - or Ice Maker
Instrument Calibration - Multimeter, Thermal Imaging, Flow Hood,
Combustion Analyzer, etc.
Lighting
Emergency Light (Not an Emergency Exit Light Sign) - An emergency light
is a battery-backed lighting device that comes on automatically when a
building experiences a power outage.

Emergency Exit Light Sign (Not an Emergency Light) - is a device in a


public facilities denoting the location of the emergency exit , guiding
people to the closest exit in case of fire or other emergency.
TING FIXTURE
Lighting for Parking Lot - the system

BLE TESTING
Manhole - or alternatively utility hole, cable chamber, maintenance hole,
inspection chamber, access chamber, confined space.
AIR SWITCH (ABOVE 600V)
Mechanical Room

CABLE TESTING
SWITCH - METAL ENCLOSED
Multizone Air Handling Unit - or Multi-zone systems provide more than
one area of a building with cooling and heating. Each zone can have a
different temperature regulated with separate thermostats.

TION PANEL
Overhead Garage Door - is a large door on a garage/loading dock area
that can either be opened manually or by an electric operator
Oven - or convection oven, fan oven, turbo oven
Pallet Jack - or Pallet Truck, or Pump Truck Pallet lift, Stacker lift. CSI # 1
22 00 Cranes and Hoists

Payment Approval Process (PAPR)


This procedure for the review and approval for payment of invoices for
services and goods to ensure UNC-Charlotte is paid in a timely and
responsible manner.

Portable Fume Collector - This system is ideal for smaller welding shops.
HEAT EXCHANGER
Post Indicating Valve

METERING DEVICE

ER MANAGEMENT SYSTEM
Pump - (HVAC) are also known as Primary chilled water pump, Primary
hot water pump, Secondary chilled water pump, Secondary hot water
pump, Chilled water pump, Building chilled water pumps, System chilled
water pump, Condenser water pump, Inline chilled water pump, Inline hot
water pump, Dual temperature water pump, Hot water pump, Building hot
water pump, System hot water, Boiler water pump. It is part of HVAC
systems are designed to provide water flow to the building or to provide
constant and or variable flow through HVAC equipment.

Boiler Feed Water Pump - is a specific type of pump used to pump feed
water into a steam boiler. CSI # 23 53 13
Chemical Water Treatment Pump

Condensate Return Pump Unit - Are utilized to collect condensate in


piping systems and pump it back to the mechanical room for re-use in the
boiler. Typically, condensate return units will pump back to a boiler feed
unit with make-up water provisions, which in turn supplies water on boiler
demand.

Domestic Cold Water Pump - or Circulating cold/hot Water Pump


Circulating Water Pump. CSI # 22 11 23

Fire Pump/Jockey Pump - is a part of fire sprinkler systems.


Fuel Oil Pump CSI # 23 12 13
Gasoline Dispensing Pump CSI # 23 12 16

Sump Pump - and or elevator sump pump. A sump pump is a pump used
to remove water that has accumulated in a water collecting sump basin,
commonly found in the basement of buildings and are used where
basement flooding happens regularly and to remedy dampness where the
water table is above the foundation of the building. CSI # 22 14 29

Water Source Heat Pump (WSHP) - A water source heat pump is a selfcontained water-cooled packaged heating and cooling unit with a
reversible refrigerant cycle. Its components are typically enclosed in a
common casing, and include a tube-in-tube heat exchanger, a
heating/cooling coil, a compressor, a fan, a reversing valve and controls.
A boiler/water heater is generally used for adding heat to the condensing
water during peak heating periods, if necessary. The system also utilizes
a water cooling tower to reject the heat energy from the condenser water
loop during periods of high cooling demand.
Water source heat pump units can be suspended in the ceiling plenum,
floor mounted behind walls, mechanical room and/or placed directly in the
occupied space as a console unit. There are also rooftop and unit
ventilator type water source heat pumps.
Refrigerator - household or commercial, with evaporator and condenser
coils in same unit, not a split system.
Refrigerant Gas Monitoring System Roof - The weather proofing material is the topmost or outermost layer
(skin) on the roof, exposed to the weather.
Roof Top Unit

Emergency Eyewash or Emergency Shower.

Stairway - or Staircase, Stairwell, Flight of Stairs.


SFER SWITCH
Fuel Storage Tank
Hot Water Storage Tank - or hot water tank, thermal storage tank, hot
water thermal storage unit, heat storage tank, hot water cylinder) is a
water tank that is used for storing hot water for space heating or domestic
use. A heavily insulated tank can retain heat for days. Hot water tanks
may have a built-in gas or oil burner system, or electric immersion
heaters, or may use an external heat exchanger to heat water from
another energy source such as district heating.

FOUR LINES
Emergency Telephone Elevator - Emergency telephone in passenger
elevator.
Emergency Telephone - Voice communication unit, wall mounted unit and
pedestal unit.

Electrical transformers are used to "transform" voltage from one level to


another, usually from a higher voltage to a lower voltage.

Electrical Transformer - typically part of HV Distribution System,

Traffic Signal Control System - or Traffic lights, stoplights, traffic lamps,


Signal light, push button, walk sign, voice activated speaker and etc. are
signaling devices positioned at road intersections, pedestrian crossings
and other locations to control competing flows of traffic. CSI # 34 41 13

URGE SUPPRESSION

KAGED TYPE

Variable Air Volume - or Terminal Unit (TU), Constant Air Volume (CAV),
Fan Powered Series Terminal (FPSU), Fan-Powered Parallel Terminal
(FPPU) Single Duct Terminal Units (SDTU), Dual-Duct Terminal Unit
(DDTU), Round-In/Round-Out VAV Unit (VRRF).
Commercial Unit Vehicle - To be reserved for use in identifying
commercial unit vehicles by Automotive and Motor Fleet.
Golf Car - or Golf Cart, Golf Buggy, Cart Ezgo, Utility Vehicle, Utility Cart.
Variable Frequency Drive - or Adjustable-Speed Drive, Adjustable
Frequency Drives, Variable Speed Drives, AC Drives, Microdrives,
Inverter Drives. CSI # 26 29 23
Vibration Analysis - or Vibration Test Is helpful in determining what is
going wrong in mechanical equipment. Vibration signatures can find
problems with balance, missing gear teeth, wear and alignment in rotating
reciprocating machines such as motors, pumps, chillers, compressors
and bearings.
Water fountain - or Drinking Fountain.
Oscillating Edge Sander Planer Table Saw

PM_Tasks

A-HP-LASERJET2
A-IBM-PS2
A-PC
A-STD-PC
A-SUN-COMPUTER
A-XEROX-COPIER-1
ACB
ACP
ACU
AHU
AIR-CONDITIONER
AIR-HANDLER-20HP
AIR-HANDLER-30HP
AIR-PUMP
AS400
ATS
BCH
BD
BLR
BMA
BMS
BOI
BOILER
C100
CAC
CBD
CCP
CCT
CHILLED-WATER-PU
CHL
CHP
CIR
COMPRESS
CONCEN
CONDENSER
COOL-250
COOL-50
CRP
CTR
CUH
CWP
DSW
DTT
DWP
ECP
ELEVATOR
ELF
EMS
EPG
EPS
ESB

HP Laser Jet II Printer


PS2 Computer
Desktop Computer
PC Compatible
Sun Work Station
Departmental Copier
AIR BREAKER
RETURN AIR FAN
AC UNIT TERMINAL TYPE
AIR HANDLER UNIT
Air Conditioner
Air Handler 20 HP
Air Handler 30 HP
Air Pump
IBM AS400 Workstation
AUTOMATIC TRANSFER SWITCH
BATTERY CHARGER
BUS DUCT
BUILDING TOURS - ROOF INSPECTIONS
BATTERY METERING SYSTEM
BUILDING MANAGEMENT SYSTEM
HEATING BOILER, GAS
Boiler
Pen Plotter
COMPUTER ROOM AC UNIT
CIRCUIT BREAKER
CHILLER CONTROL PANEL
CLOSED COIL WET TYPE COOLING TOWER
Chilled Water Pump
CENTRIFUGAL CHILLER
CHILLED WATER PUMP
CIRCULATING PUMP
Air Compressor
Concentrator
Condensing Unit
Air Conditioner
Air Conditioner
CONDENSATE RETURN PUMP
CROSS FLOW COOLING TOWER
CABINET UNIT HEATER
CONDENSER WATER PUMP
DISCONNECT SWITCH
DRY TYPE TRANSFORMER
DOMESTIC WATER PUMP
GENERATOR CONTROL PANEL
Elevator
EMERGENCY LIGHTING FIXTURE
ELECTRIC MOTOR STARTER
EMERGENCY POWER GENERATOR
EMERGENCY POWER MANAGEMENT SYSTEM
ENGINE START BATTERIES

EUH
EXHAUST
EXHAUST-FAN
FAN-ASSEMBLY
FBP
FCU
FHP
FIRE-EXT.-10-DRY
FIRE-EXT.-20-CO2
FIRE-EXT.-20-DRY
FJP
FMS
FOC
FOP
FSP
FSS
GENERATOR
GFP
GSW
GWP
HEAT-PUMP
HOT-WATER-PUMP
HP2
HPSERVER-A
HTD
HTR
HWH
HWP
IBMRT
KEF
LPP
LVTC
MAC
MAKE-UP-AIR-UNIT
MAS
MCC
MODEM
MOTOR-FAN
MTS
MUP
MVC
MVS
NCR-TWR
NETFRAME-A
OAF
ODP
PAP
PAS
PBX-NR
PCAT
PDU

ELECTRIC UNIT HEATER


Exhaust Ventilation Hood
Exhaust Fan
AHU Fan Assembly
FIRE BOOSTER PUMP
FAN COIL UNIT
FIRE HOUSE PUMP
Fire Extinguisher, #10 Dry Chemical
Fire Extinguisher, #20 CO2
Fire Extinguisher, #20 Dry Chemical
FIRE JOCKEY PUMP
FIRE MIST SYSTEM
FUEL OIL CONTROLS
FUEL OIL PUMP
STAND PIPE SYSTEM
SPRINKLER SYSTEM
Electricity Generator
GROUND FAULT PROTECTION
GENERATOR SWITCHGEAR
SUMP PUMP
Heat Pump
Hot Water Pump
HP Laserjet Printer 2
HP Pentium Pro Server
DUCT HEATER
SPACE HEATER
HOT WATER UNIT HEATER
HOT WATER PUMP
IBM RT PC Workstations
KITCHEN EXHAUST
LIGHTING POWER PANEL
LOW VOLTAGE CABLE TESTING
Apple Macintosh
Make Up Air Unit
MEDIUM VOLTAGE AIR SWITCH (above 600V)
MOTOR CONTROL CENTER
Hayes 9600 Baud Modem
Fan Motor
MANUAL TRANSFER SWITCH
MAKE UP WATER PUMP
MEDIUM VOLTAGE CABLE TESTING
MEDIUM VOLTAGE SWITCH - METAL ENCLOSED
NCR Tower
Netframe Server
OUTSIDE AIR FAN
OUTPUT DISTRIBUTION PANEL
PRE ACTION PANEL
PRE ACTION SYSTEM
PBX Machine
IBM AT Personal Computer
POWER DISTRIBUTION UNIT

PHONE
PHX
PQM
PROCESS-AIR-COMP
PS2/95
RAF
REFRIG
RPP
SAF
SBD
SEF
SHREDDER
SMOKE-DETECTOR
SPF
STDPRINT
STS
SUH
SUN
SUPPLY-FAN
T-2LINE-A
T-4LINE-A
TAF
TEST-100
TRANSFMR
TRANSFORMER
TVS
UMB
UPB
UPM
UPS
USS
USW
VAC-2000
VAX
VAXPRINT
VFD
VT-320
WTT
X100

Lexar Phone
PLATE AND FRAME HEAT EXCHANGER
POWER SYSTEM METERING DEVICE
Process Air Compressor
IBM PS/2 Computer
RETURN AIR FAN
Refrigerator
REMOTE POWER PANEL
SUPPLY AIR FAN
SWITCHBOARD
SMOKE EXHAUST FAN
Paper Shredder
Smoke Detector
SMOKE PURGE FAN
Standard Printer
STATIC TRANSFER SWITCH
STEAM UNIT HEATER
Sun Workstation
Supply Fan
Type A phone w/two lines
Type A phone w/four lines
TRANSFER AIR FAN
Test Station
60 Hz - 50 Hz Transformer
Transformer
TRANSIENT AND SURGE SUPPRESSION
UPS MAINTENANCE BYPASS
UPS BATTERY STRING
UPS MODULE
UPS SYSTEM PACKAGED TYPE
UNIT SUBSTATION
UPS SWITCHGEAR
Standard Floor Vacuum
DEC VAX Minicomputer
VAX Printer
VARIABLE FREQUENCY DRIVE
Display Terminal
WET TYPE TRANSFORMER
Copier

Potrebbero piacerti anche