Sei sulla pagina 1di 123

FlexiPacket Microwave

Solution Site Installation Abstract


(This document does not contain information on commercial availability)

A25000-A1200-A031-02-76P1
(March 2010)

The information in this document is subject to change without notice and describes only the product defined in the introduction of this documentation. This
documentation is intended for the use of Nokia Siemens Networks customers only for the purposes of the agreement under which the document is submitted, and
no part of it may be used, reproduced, modified or transmitted in any form or means without the prior written permission of Nokia Siemens Networks. The
documentation has been prepared to be used by professional and properly trained personnel, and the customer assumes full responsibility when using it. Nokia
Siemens Networks welcomes customer comments as part of the process of continuous development and improvement of the documentation.
The information or statements given in this documentation concerning the suitability, capacity, or performance of the mentioned hardware or software products are
given as is and all liability arising in connection with such hardware or software products shall be defined conclusively and finally in a separate agreement
between Nokia Siemens Networks and the customer. However, Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions
contained in the document are adequate and free of material errors and omissions. Nokia Siemens Networks will, if deemed necessary by Nokia Siemens
Networks, explain issues which may not be covered by the document.
Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO EVENT WILL NOKIA SIEMENS NETWORKS BE LIABLE FOR
ERRORS IN THIS DOCUMENTATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR
CONSEQUENTIAL OR ANY LOSSES,SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS
OPPORTUNITY OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION IN IT.
This documentation and the product it describes are considered protected by copyrights and other intellectual property rights according to the applicable laws.
The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark of Nokia Corporation. Siemens is a registered trademark of
Siemens AG.
Other product names mentioned in this document may be trademarks of their respective owners, and they are mentioned for identification purposes only.
Copyright Nokia Siemens Networks 2009. All rights reserved.

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 1

Solution Site Installation Abstract

Name of the Radio Solution

FlexiPacket Microwave

Mechanical compatibility

XD, FH

Frequency Range

7-13-15-18-23-38 GHz

Capacity

Ethernet traffic

Configuration

1+0
1+1 HSBY

Indoor Device

FlexiPacket Hub A2200


FlexiPacket Hub A1200

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 2

INDEX

1+0 INTEGRATED SYSTEM (XD FlexiPacket Radio)


- Standard terminal (1+0 Configuration)
- XD Antennas

Sheet
Sheet

7
8

1+0 INTEGRATED SYSTEM (FH FlexiPacket Radio)


- Standard terminal (1+0 Configuration)
- FH Antennas

Sheet
Sheet

9
10

1+1 INTEGRATED SYSTEM (XD FlexiPacket Radio)


- Protected terminal (1+1 Configuration): Hot-Standby
- Layout
- Protection Covers and O-rings
- Polarization Change
- P/N, Attenuation and Flanges
- XD Antennas

Sheet
Sheet
Sheet
Sheet
Sheet
Sheet

11
12
13
14
15
16

1+1 INTEGRATED SYSTEM (FH FlexiPacket Radio)


- Protected terminal (1+1 Configuration): Hot-Standby
- Layout
- 1+1 Coupler particular
- 1+1 Coupler and Waveguide Adapter P/N, Attenuation and Flanges
- FH Antennas

Sheet
Sheet
Sheet
Sheet
Sheet

17
18
19
20
21

1+0 NOT INTEGRATED SYSTEM (XD FlexiPacket Radio)


- Standard terminal (1+0 Configuration)
- Layout
- Pole Fixing
- Wall Fixing
- Protection Covers and O-rings
- P/N, Attenuation and Flanges
- XD Antennas

Sheet
Sheet
Sheet
Sheet
Sheet
Sheet
Sheet

22
23
24
25
26
27
28

1+0 NOT INTEGRATED SYSTEM (FH FlexiPacket Radio)


- Standard terminal (1+0 Configuration)
- Layout
- FH alignment unit and Waveguide Adapter
- Waveguide Adapter P/N, Attenuation and Flanges
- XD Antennas

Sheet
Sheet
Sheet
Sheet
Sheet

29
30
31
32
33

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 3

1+1 NOT INTEGRATED SYSTEM (XD FlexiPacket Radio)


- Protected terminal (1+1 Configuration): Hot-Standby
- Layout
- Pole Fixing
- Wall Fixing
- Protection Covers and O-rings
- P/N, Attenuation and Flanges
- XD Antennas

Sheet
Sheet
Sheet
Sheet
Sheet
Sheet
Sheet

34
35
36
37
38
39
40

1+1 NOT INTEGRATED SYSTEM (FH FlexiPacket Radio)


- Protected terminal (1+1 Configuration): Hot-Standby
- Layout
- FH alignment unit, 1+1 Coupler and waveguide adapter
- 1+1 Coupler and Waveguide Adapter P/N, Attenuation and Flanges
- FH Antennas

Sheet
Sheet
Sheet
Sheet
Sheet

41
42
43
44
45

NOT INTEGRATED SYSTEM (with Flexible Waveguide)


- Solution With Flexible Waveguide Connection (XD FlexiPacket Radio)
- Solution With Flexible Waveguide Connection (FH FlexiPacket Radio)
- Solution With Flexible Waveguide Connection, Attenuation

Sheet
Sheet
Sheet

46
47
48

Sheet

49

Sheet
Sheet
Sheet

50
51
52

11 OUTDOOR ASSEMBLY (XD FlexiPacket Radio)


- Assembly on support frame
- Dimension

Sheet
Sheet

53
54

12 OUTDOOR ASSEMBLY (FH FlexiPacket Radio)


- Assembly on alignment unit
- Dimension

Sheet
Sheet

55
56

13 OUTDOOR ASSEMBLY (XD and FH FlexiPacket Radio)


- External connectors
- In/out Ethernet cable connector
- In/out Ethernet cable
- PS Connector (on request)

Sheet
Sheet
Sheet
Sheet

57
58
59
60

10 NOT INTEGRATED SYSTEM (with Elliptical Waveguide)


This solution is not the standard solution. It is available on demand.
- Solution with elliptical waveguide connection
for single polarization (XD FlexiPacket radio)
- Solution with elliptical waveguide connection
for single polarization (FH FlexiPacket radio)
- Solution with elliptical wave guide pressurization with external dehydrator
- Elliptical wave guide

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 4

- ODU PS Cable (on request)


- ACG Connector for fine alignment
- Ground bolt and ground cable
- Polarization application

Sheet
Sheet
Sheet
Sheet

61
62
63
64

14 ETHERNET CABLE AND POWER SUPPLY CABLE CONNECTIONS


- Grounding connections
- Pole fixing of the grounding plate kit
- Typical fixing

Sheet
Sheet
Sheet

65
66
67

15 FlexiPacket Hub A-2200


- Rack Assembly
- Grounding connections
- Installing the device in a 19-inch rack (Standard solution)
- Installing the device in an ETSI rack (Option on request)
- Installing the device in a 23-inch rack (Option on request)
- Installing the device on a wall
- Installing the patch panel
- Equipment composition
- Equipment composition table
- E1/T1 Patch Panel
- Main unit functions
- Main unit - 1000Base-X Network Ports connections (1)
- Main unit - 1000Base-X Network Ports connections (2)
- Main unit - 1000Base-X Network Ports connections (3)
- Main unit Console Port connection
- Main unit Management Port connection
- Main unit - Alarms Interface connections
- 10-port 100/1000BASE-FX optical fiber access module connections (1)
- 10-port 100/1000BASE-FX optical fiber access module connections (2)
- 10-port 100/1000BASE-FX optical fiber access module connections (3)
- 8-port 10/100/1000BASE-T copper cable access module connections
- 8-port E1/T1 configuration
- 16-port E1/T1 configuration
- 32-port E1/T1 configuration
- E1/T1 connection
- OC3/STM1 CES Access module connections
- Front -facing AC power supply connection
- Front -facing DC power supply connection
- Cable trays

Sheet
Sheet
Sheet
Sheet
Sheet
Sheet
Sheet
Sheet
Sheet
Sheet
Sheet
Sheet
Sheet
Sheet
Sheet
Sheet
Sheet
Sheet
Sheet
Sheet
Sheet
Sheet
Sheet
Sheet
Sheet
Sheet
Sheet
Sheet
Sheet

68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 5

16 FlexiPacket Hub A-1200


- Modular version in Rack Assembly
- Fixed version in Rack Assembly
- Grounding connections
- Installing the device in a 19-inch rack (Standard solution)
- Installing the device in an ETSI rack (Option on request)
- Installing the device in a 23-inch rack (Option on request)
- Installing the device on a wall
- Equipment composition
- Equipment composition table
- Fixed Version - Main Unit Functions
- Modular Version - Main Unit Functions
- Main Unit (Fixed Version) - 1000base-X Network Ports Connections
- Main Unit (Modular Version) - 1000base-X Network Ports Connections
- Main unit - 1000Base-X Network Ports connections
- Main Unit (Modular/Fixed Version) - Console Port Connection
- Main Unit (Modular/Fixed Version) - Management Port Connection
- Main Unit (Modular/Fixed Version) - Alarms Interface Connections
- Main Unit (Fixed Version) - Ports 10/100/1000base-T
Copper Cable Interface Connections
- Main Unit (Modular Version) - Ports 10/100/1000base-T
Copper Cable Interface Connections
- Main Unit (Modular/Fixed Version) - Ports E1/T1 Interface Connections
- E1/T1 Connection
- Main Unit (Modular/Fixed Version) - Dc Power Supply Connection

17 ACCESSORIES
- FlexiPacket Radio Cables
- FlexiPacket Radio Cables accessories
- FlexiPacket Radio Connectors
- FlexiPacket Hub Cables
- Crimping tools

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet
Sheet
Sheet
Sheet
Sheet
Sheet
Sheet
Sheet
Sheet
Sheet
Sheet
Sheet
Sheet
Sheet
Sheet
Sheet
Sheet

97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113

Sheet 114
Sheet
Sheet
Sheet
Sheet

115
116
117
118

Sheet
Sheet
Sheet
Sheet
Sheet

119
120
121
122
123

Sheet 6

1+0 INTEGRATED SYSTEM (XD FlexiPacket Radio)


1+0 CONFIGURATION
(Terminal)

XD Integrated antenna
(for P/N see sheet 8)

PS cable
(See sheets 60 and 61)
(b)
XD FlexiPacket Radio
(See sheets 53, 54 and 57)

FlexiPacket Hub A-2200


(See sheets from 68 to 96)

Ethernet cable
(See sheets 65, 66 and 67)
(a)

FlexiPacket Hub A-1200


(See sheets from 97 to 118)
19/23/N3 ETSI Rack

(a) Cable delivered as standard supply: max length = 100 m. This cable must be connected to one of the
available Ethernet connectors (port#1 to port#7) of the 8-port Ethernet access module on the left side of the
FlexiPacket Hub A-2200 or to one of the available Ethernet connectors (port#1 to port#7) of the FlexiPacket Hub
A-1200.
(b) -48 VDC Power Supply Unit available in the site.

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 7

1+0 INTEGRATED SYSTEM


XD ANTENNAS

ANTENNA
DIAMETER (m)
FREQUENCY
BAND
(GHz)

FEEDER
FLANGE
0.2

0.3

0.6

0.8

X
X

13

15

18

23

38

1.2

PDR84

PBR120

PBR140

PBR220

PBR220

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

PBR320

Sheet 8

1+0 INTEGRATED SYSTEM (FH FlexiPacket Radio)


1+0 CONFIGURATION
(Terminal)

FH antenna
(for P/N see sheet 10)

FH FlexiPacket Radio
(See sheets 55, 56 and 57)

PS cable
(See sheets 60 and 61)
(b)

FlexiPacket Hub A-2200


(See Sheets from 68 to 96)

Ethernet cable
(See sheets 65, 66 and 67)
(a)

FlexiPacket Hub A-1200


(See sheets from 97 to 118)

19/23/N3 ETSI Rack

(a) Cable delivered as standard supply: max length = 100 m. This cable must be connected to one of the
available Ethernet connectors (port#1 to port#7) of the 8-port Ethernet access module on the left side of the
FlexiPacket Hub A-2200 or to one of the available Ethernet connectors (port#1 to port#7) of the FlexiPacket Hub
A-1200.
(b) -48 VDC Power Supply Unit available in the site.

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 9

1+0 INTEGRATED SYSTEM


FH ANTENNAS

ANTENNA
DIAMETER (m)

FREQUENCY
BAND
(GHz)

FEEDER
FLANGE
0.2

0.3

0.6

0.9

1.2

1.8

2.4

UDR80

13

15

18

UBR220

UBR220

23

38

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

UBR120

UBR140

UBR320

Sheet 10

1+1 INTEGRATED SYSTEM (XD FlexiPacket Radio)


1+1 CONFIGURATION
Hot-StandBy
(Terminal)
XD Integrated antenna
(for P/N see sheet 16)

XD FlexiPacket Radio
(See sheets 53, 54 and 57)

1+1 integrated supporting frame


(See sheets from 12 to 15)

PS cables
(See sheets 60 and 61)
(b)
Ethernet cables
(See sheets 65, 66 and 67)
(a)
FlexiPacket Hub A-2200
(See Sheets from 68 to 96)

FlexiPacket Hub A-1200


(See sheets from 97 to 118)
19/23/N3 ETSI Rack

(a) Cables delivered as standard supply: max length = 100 m. These cables must be connected to two of the
available Ethernet connectors (port#1 to port#7) of the 8-port Ethernet access module on the left side of the
FlexiPacket Hub A-2200 or to one of the available Ethernet connectors (port#1 to port#7) of the FlexiPacket Hub
A-1200. One port must be even, the other port must be odd.
(b) -48 VDC Power Supply Unit available in the site.
FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 11

1+1 INTEGRATED SYSTEM (XD FlexiPacket Radio)


LAYOUT

Installation pole
(75-115 mm)
UP
MAIN
XD FlexiPacket Radio

Down
protection

ODU safety
hook

1+1 supporting frame


(for P/N see sheet 15)

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 12

1+1 INTEGRATED SYSTEM (XD FlexiPacket Radio)


PROTECTION COVERS AND O-RINGS

(a)

(b)

Protection
cover

O-RING

(b)

Protection
cover

(a)(b)

(a) The O-rings are delivered with the frame.


(b) Remove during installation

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 13

1+1 INTEGRATED SYSTEM (XD FlexiPacket Radio)


POLARIZATION CHANGE

STEP TWIST

POLARIZATION CHANGE

V
STEP TWIST

VERTICAL POLARIZATION

HORIZONTAL POLARIZATION

The polarization change can be executed by loosening the fixing screws of the step twist and rotating the disk
until the reference notches on the desired polarization are aligned.
At the end of the operation only, tighten the screws while ensuring alignment of the reference notches.

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

PROTECTION
COVER

Sheet 14

1+1 INTEGRATED SYSTEM (XD FlexiPacket Radio)


P/N, ATTENUATION AND FLANGE

1+1 FRAME
UNBALANCED HSBY
FREQ.
BAND
(GHz)
P/N

1+1 FRAME
BALANCED HSBY

COUPLING
ATTENUATION
(dB)
MAIN

ST.BY

P/N

COUPLING
ATTENUATION
(dB)

FRAME
FLANGE
(to Antenna)

T555IU11.07

1.0

101

T555IB11.07

30.3

UDR84

13

T555IU11.13

1.2

101

T555IB11.13

30.3

UBR120

15

T555IU11.15

1.3

101

T555IB11.15

30.3

UBR140

18

T555IU11.18

1.3

101

T555IB11.18

30.3

UBR220

23

T555IU11.23

1.3

101

T555IB11.23

30.3

UBR220

38

T555IU11.38

1.3

101

T555IB11.38

30.3

UBR320

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 15

1+1 INTEGRATED SYSTEM


XD ANTENNAS

ANTENNA
DIAMETER (m)
FREQUENCY
BAND
(GHz)

FEEDER
FLANGE
0.2

0.3

0.6

0.8

X
X

13

15

18

23

38

1.2

PDR84

PBR120

PBR140

PBR220

PBR220

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

PBR320

Sheet 16

1+1 INTEGRATED SYSTEM (FH FlexiPacket Radio)


1+1 CONFIGURATION
Hot-StandBy
(Terminal)
FH antenna
(for P/N see sheet 21)

1+1 Coupler
(see sheet from 19 to 20)

FH FlexiPacket Radio
(See sheets 55, 56 and 57)

PS cables
(See sheets 60 and 61)
(b)

Ethernet cables
(See sheets 65, 66 and 67)
(a)

FlexiPacket Hub A-2200


(See Sheets from 68 to 96)
FlexiPacket Hub A-1200
(See sheets from 97 to 118)

19/23/N3 ETSI Rack

(a) Cables delivered as standard supply: max length = 100 m. These cables must be connected to two of the
available Ethernet connectors (from port#1 to port#7) of the FlexiPacket Hub A-2200 or to one of the available
Ethernet connectors (port#1 to port#7) of the FlexiPacket Hub A-1200. One port must be even, the other port
must be odd. (b) -48 VDC Power Supply Unit available in the site.
FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 17

1+1 INTEGRATED SYSTEM (FH FlexiPacket Radio)


LAYOUT

Installation pole
(48-115 mm)

FH FlexiPacket Radio

UP
protection
1+1 Coupler

DOWN
main

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 18

1+1 INTEGRATED SYSTEM (FH FlexiPacket Radio)


1+1 COUPLER PARTICULAR

1+1 Coupler
(for P/N see sheet 20)

FH antenna

Fix the
Protection
ODU

Fix the
Main ODU

FRONT VIEW

SIDE VIEW

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 19

1+1 COUPLER- (FH FlexiPacket Radio)


P/N, ATTENUATION AND FLANGE

FREQUENCY BAND
(GHz)

Waveguide Adapter
P/N

FLANGE
(to Antenna)

T55055.01

UDR80

13

T55055.02

UBR120

15

T55055.03

UBR140

18-23

T55055.04

UBR220

38

T55055.08

UBR320

WAVEGUIDE ADAPTER P/N AND FLANGE

FREQUENCY BAND
(GHz)

Waveguide Adapter
P/N

FLANGE
(to Antenna)

T55055.01

UDR80

13

T55055.02

UBR120

15

T55055.03

UBR140

18-23

T55055.04

UBR220

38

T55055.08

UBR320

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 20

1+1 INTEGRATED SYSTEM


FH ANTENNAS

ANTENNA
DIAMETER (m)

FREQUENCY
BAND
(GHz)

FEEDER
FLANGE
0.2

0.3

0.6

0.9

1.2

1.8

2.4

UDR80

13

15

18

UBR220

UBR220

23

38

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

UBR120

UBR140

UBR320

Sheet 21

1+0 NOT INTEGRATED SYSTEM (XD FlexiPacket Radio)


1+0 CONFIGURATION
(Terminal)
Installation pole
(75-115 mm)
XD Integrated antenna
(for P/N see sheet 28)

Flexible waveguide supports


(See sheets 46 and 48)

Flexible waveguide
(See sheets 46 and 48)

XD FlexiPacket Radio
(See sheets 53, 54 and 57)

Vertical 1+0 frame


(See sheets from 23 to 27)

PS cable
(See sheets 60 and 61)
(b)

Ethernet cable
(See sheets 65, 66 and 67)
(a)
FlexiPacket Hub A-1200
(See sheets from 97 to 118)

FlexiPacket Hub A-2200


(See Sheets from 68 to 96)

19/23/N3 ETSI Rack

(a) Cable delivered as standard supply: max length = 100 m. This cable must be connected to one of the
available Ethernet connectors (from port#1 to port#7) of the FlexiPacket Hub A-2200 or to one of the available
Ethernet connectors (port#1 to port#7) of the FlexiPacket Hub A-1200.
(b) -48 VDC Power Supply Unit available in the site.
FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 22

VERTICAL 1+0 NOT INTEGRATED SYSTEM (XD FlexiPacket Radio)


LAYOUT

Installation pole
(75-115 mm)

1+0 supporting frame


(For P/N see sheet 28)
XD FlexiPacket Radio

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 23

VERTICAL 1+0 NOT INTEGRATED SYSTEM (XD FlexiPacket Radio)


POLE FIXING

Installation pole
(75-115 mm)

1+0 supporting frame

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 24

VERTICAL 1+0 NOT INTEGRATED SYSTEM (XD FlexiPacket Radio)


WALL FIXING

(b)

Protection
cover

Insert (a)

1+0 supporting
frame

(a) The inserts are not delivered with the frame, if this fixing is requested they have to be separately
provided.
(b) Remove during installation

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 25

VERTICAL 1+0 NOT INTEGRATED SYSTEM (XD FlexiPacket Radio)


PROTECTION COVER and O-RINGS

(b)

(a)

Protection
cover

O-RING

Protection
cover

(b)

(a) The O-rings are delivered with the frame.


(b) Remove during installation

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 26

1+0 NOT INTEGRATED SYSTEM (XD FlexiPacket Radio)


P/N AND FLANGE

FREQUENCY BAND
(GHz)

1+0 FRAME
P/N

FRAME FLANGE
(to Antenna)

T555RS10.07

UDR80

13

T555RS10.13

UBR120

15

T555RS10.15

UBR140

18

T555RS10.18

UBR220

23

T555RS10.18

UBR220

38

T555RS10.28

UBR340

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 27

1+0 INTEGRATED SYSTEM


XD ANTENNAS

ANTENNA
DIAMETER (m)
FREQUENCY
BAND
(GHz)

FEEDER
FLANGE
0.2

0.3

0.6

0.8

X
X

13

15

18

23

38

1.2

PDR84

PBR120

PBR140

PBR220

PBR220

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

PBR320

Sheet 28

1+0 NOT INTEGRATED SYSTEM (FH FlexiPacket Radio)


1+0 CONFIGURATION
(Terminal)

FH antenna
(for P/N see sheet 33)

Flexible waveguide supports


(See sheets 46 and 48)

Flexible waveguide
(See sheets 47 and 48)

FH alignment unit
(See sheets 30 and 31)
Waveguide adapter
(See sheets 30 and 31)

ODU ground cable


(See sheet 63)

FH FlexiPacket Radio
(See sheets 55, 56 and 57)

PS cable
(See sheets 60 and 61)
(b)

Ethernet cable
(See sheets 65, 66 and 67)
(a)

FlexiPacket Hub A-2200


(See Sheets from 68 to 96)
19/23/N3 ETSI Rack
FlexiPacket Hub A-1200
(See sheets from 97 to 118)

(a) Cable delivered as standard supply: max length = 100 m. This cable must be connected to one of the
available Ethernet connectors (from port#1 to port#7) of the FlexiPacket Hub A-2200 or to one of the available
Ethernet connectors (port#1 to port#7) of the FlexiPacket Hub A-1200.
(b) -48 VDC Power Supply Unit available in the site.
FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 29

1+0 NOT INTEGRATED SYSTEM (FH FlexiPacket Radio)


LAYOUT

FH alignment unit
Waveguide adapter

FH FlexiPacket Radio

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 30

1+0 NOT INTEGRATED SYSTEM (FH FlexiPacket Radio)


FH ALIGNMENT UNIT AND WAVEGUIDE ADAPTER

Flexible Waveguide

Guide hole always up

FH alignment unit
for P/N see sheet 32)
2.5 or 3 mm

Waveguide adapter
(for P/N see sheet 32)

M8x20 screws
(8Nm)

6 mm

FH FlexiPacket Radio

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 31

1+0 NOT INTEGRATED SYSTEM (FH FlexiPacket Radio)


WAVEGUIDE ADAPTER P/N AND FLANGE

FREQUENCY BAND
(GHz)

Waveguide Adapter
P/N

FLANGE
(to Antenna)

T55055.01

UDR80

13

T55055.02

UBR120

15

T55055.03

UBR140

18-23

T55055.04

UBR220

38

T55055.08

UBR320

FH alignment unit
P/N

FREQUENCY BAND
(GHz)

FH alignment unit
20, 30, 60 (P/N)

7, 13, 15, 18, 23, 38

T55050.01

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 32

1+0 INTEGRATED SYSTEM


FH ANTENNAS

ANTENNA
DIAMETER (m)

FREQUENCY
BAND
(GHz)

FEEDER
FLANGE
0.2

0.3

0.6

0.9

1.2

1.8

2.4

UDR80

13

15

18

UBR220

UBR220

23

38

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

UBR120

UBR140

UBR320

Sheet 33

1+1 NOT INTEGRATED SYSTEM (XD FlexiPacket Radio)


1+1 CONFIGURATION
Hot-StandBy
(Terminal)

XD Integrated antenna
(for P/N see sheet 40)

Flexible waveguide supports


(See sheets 46 and 48)

XD FlexiPacket Radio
(See sheets 53, 54 and 57)
Flexible waveguide
(See sheets 46 and 48)
1+1 supporting frame-not
integrated system
(See sheets from 35 to 39)

PS cables
(See sheets 60 and 61)
(b)

Ethernet cables
(See sheets 65, 66 and 67)
(a)

FlexiPacket Hub A-2200


(See sheets from 68 to 96)

FlexiPacket Hub A-1200


(See sheets from 97 to 118)
19/23/N3 ETSI Rack

(a) Cables delivered as standard supply: max length = 100 m. These cables must be connected to two of the
available Ethernet connectors (from port#1 to port#7) of the 8-port Ethernet access module on the left side of the
FlexiPacket Hub A-2200 or to one of the available Ethernet connectors (port#1 to port#7) of the FlexiPacket Hub
A-1200. One port must be even, the other port must be odd.
(b) -48 VDC Power Supply Unit available in the site.
FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 34

1+1 NOT INTEGRATED SYSTEM (XD FlexiPacket Radio)


LAYOUT

Installation pole
(75-115 mm)

1+1 supporting frame


(for P/N see sheet 39)

Protection

MAIN

XD FlexiPacket Radio

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 35

1+1 NOT INTEGRATED SYSTEM (XD FlexiPacket Radio)


POLE FIXING

Installation pole
(75-115 mm)

1+1 supporting frame

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 36

1+1 NOT INTEGRATED SYSTEM (XD FlexiPacket Radio)


WALL FIXING

Insert

(a)

1+1 supporting
frame

(a) The inserts are not delivered with the frame, if this fixing is requested they have to be separately provided.

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 37

1+1 NOT INTEGRATED SYSTEM (XD FlexiPacket Radio)


PROTECTION COVER AND O-RINGS

Protection
cover

(a)

O-RING

Protection
cover

(a) The O-rings are delivered with the frame.

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 38

1+1 NOT INTEGRATED SYSTEM (XD FlexiPacket Radio)


P/N, ATTENUATION AND FLANGE

1+1 FRAME
UNBALANCED HSBY
FREQ.
BAND
(GHz)
P/N

1+1 FRAME
BALANCED HSBY

COUPLING
ATTENUATION
(dB)
MAIN

ST.BY

P/N

COUPLING
ATTENUATION
(dB)

FRAME
FLANGE
(to Antenna)

T555IU11.07

1.0

101

T555IB11.07

30.3

UDR84

13

T555IU11.13

1.2

101

T555IB11.13

30.3

UBR120

15

T555IU11.15

1.3

101

T555IB11.15

30.3

UBR140

18

T555IU11.18

1.3

101

T555IB11.18

30.3

UBR220

23

T555IU11.23

1.3

101

T555IB11.23

30.3

UBR220

38

T555IU11.38

1.3

101

T555IB11.38

30.3

UBR320

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 39

1+1 INTEGRATED SYSTEM


XD ANTENNAS

ANTENNA
DIAMETER (m)
FREQUENCY
BAND
(GHz)

FEEDER
FLANGE
0.2

0.3

0.6

0.8

X
X

13

15

18

23

38

1.2

PDR84

PBR120

PBR140

PBR220

PBR220

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

PBR320

Sheet 40

1+1 NOT INTEGRATED SYSTEM (FH FlexiPacket Radio)


1+1 CONFIGURATION
Hot-StandBy
(Terminal)

FH antenna
(for P/N see sheet 45)

Flexible waveguide supports


(See sheets 46 and 48)

Flexible waveguide
(See sheets 47 and 48)

FH alignment unit
(See sheets 42 and 43)

Waveguide adapter
(See sheets 42 and 43)

1+1 Coupler
(See sheets 42 and 43)

FH FlexiPacket Radio
(See sheets 55, 56 and 57)

PS cables
(See sheets 60 and 61)
(b)

Ethernet cables
(See sheets 65, 66 and 67)
(a)

FlexiPacket Hub A-2200


(See sheets from 68 to 96)

19/23/N3 ETSI Rack

FlexiPacket Hub A-1200


(See sheets from 97 to 118)

(a) Cables delivered as standard supply: max length = 100 m. These cables must be connected to two of the
available Ethernet connectors (from port#1 to port#7) of the FlexiPacket Hub A-2200 or to one of the available
Ethernet connectors (port#1 to port#7) of the FlexiPacket Hub A-1200. One port must be even, the other port
must be odd. (b) -48 VDC Power Supply Unit available in the site.
FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 41

1+1 NOT INTEGRATED SYSTEM (FH FlexiPacket Radio)


LAYOUT

Installation pole
(48-115 mm)

FH alignment unit

Waveguide adapter
(for P/N see sheet 44)
UP
protection
FH FlexiPacket Radio

1+1 Coupler
(for P/N See sheet 44)

DOWN
main

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 42

1+1 NOT INTEGRATED SYSTEM (FH FlexiPacket Radio)


FH ALIGNMENT UNIT, 1+1 COUPLER AND WAVEGUIDE ADAPTER

1+1 Coupler
(for P/N See sheet 44)

Fix the
Waveguide adapter
(see figure - for P/N see
sheet 44)

Fix the
Protection ODU

Fix the
Main ODU

SIDE VIEW

FRONT VIEW

Flexible Waveguide
Guide hole always up
2.5 or 3 mm

Waveguide adapter

FH alignment unit
6 mm

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

M8x20 screws
(8Nm)

Sheet 43

1+1 COUPLER- (FH FlexiPacket Radio)


P/N, ATTENUATION AND FLANGE

FREQUENCY BAND
(GHz)

Waveguide Adapter
P/N

FLANGE
(to Antenna)

T55055.01

UDR80

13

T55055.02

UBR120

15

T55055.03

UBR140

18-23

T55055.04

UBR220

38

T55055.08

UBR320

Waveguide Adapter
P/N AND FLANGE

FREQUENCY BAND
(GHz)

Waveguide Adapter
P/N

FLANGE
(to Antenna)

T55055.01

UDR80

13

T55055.02

UBR120

15

T55055.03

UBR140

18

T55055.04

UBR220

23

T55055.04

UBR220

38

T55055.08

UBR320

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 44

1+1 INTEGRATED SYSTEM


FH ANTENNAS

ANTENNA
DIAMETER (m)

FREQUENCY
BAND
(GHz)

FEEDER
FLANGE
0.2

0.3

0.6

0.9

1.2

1.8

2.4

UDR80

13

15

18

UBR220

UBR220

23

38

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

UBR120

UBR140

UBR320

Sheet 45

NOT INTEGRATED SYSTEM


SOLUTION WITH FLEXIBLE WAVEGUIDE CONNECTION (XD FlexiPacket Radio)

P
USE ONLY THE SCREWS
SUPPLIED WITH THE
ANTENNA

VERTICAL
POLARIZATION

P
U

HORIZONTAL
POLARIZATION
75115mm POLE
(recommended 115mm)

POLE FIXING for

(a) FLEXIBLE WAVEGUIDE

1+0 VERTICAL FRAME


or

FLEXIBLE WAVEGUIDE

1+1 SUPPORTING FRAME

SUPPORTING FRAME WITH PASSING HOLE


USE ONLY THE SCREWS SUPPLIED
WITH THE FLEXIBLE WAVEGUIDE
or
SUPPORTING FRAME WITH BLIND HOLE
USE ONLY THE SCREWS SUPPLIEDWITH THE
SUPPORTING FRAME

PRESSURIZABLE FLANGE

UNPRESSURIZABLE FLANGE

(a) - 1 pole fixer is delivered with a waveguide of length 0.6 m;


- 2 pole fixers are delivered with a waveguide of length 1 m.

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 46

NOT INTEGRATED SYSTEM


SOLUTION WITH FLEXIBLE WAVEGUIDE CONNECTION (FH FlexiPacket Radio)
USE ONLY THE SCREWS
SUPPLIED WITH THE
ANTENNA

VERTICAL
POLARIZATION

HORIZONTAL
POLARIZATION
48115mm POLE
(recommended 115mm)

(a) POLE FIXING for

FLEXIBLE WAVEGUIDE
1+0 FRAME NOT INTEGRATED SYSTEM
FLEXIBLE WAVEGUIDE

or
1+1 FRAME NOT INTEGRATED SYSTEM

WAVEGUIDE ADAPTER
USE ONLY THE SCREWS SUPPLIED
WITH THE FLEXIBLE WAVEGUIDE
PRESSURIZABLE FLANGE
UNPRESSURIZABLE FLANGE

(a) - 1 pole fixer is delivered with a waveguide of length 0.6 m;


- 2 pole fixers are delivered with a waveguide of length 1 m.

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 47

NOT INTEGRATED SYSTEM


SOLUTION WITH FLEXIBLE WAVE GUIDE

ATTENUATION WITH FLEXIBLE WAVE GUIDE

FREQUENCY BAND
(GHz)

FLEXIBLE
WAVE GUIDE KIT
(L. = 600 mm) (a)
ATTENUATION
Type
(dB)

FLEXIBLE
WAVE GUIDE KIT
(L. = 1000 mm) (b)
ATTENUATION
Type
(dB)

UDR-PDR 84

0.18

UDR-PDR 84

0.39

13

UBR-PBR 120

0.30

UBR-PBR 120

0.50

15

UBR-PBR 140 (c)

0.406

UBR-PBR 140 (c)

0.66

18

UBR-PBR 220

0.72

UBR-PBR 220

1.20

23

UBR-PBR 220

0.72

UBR-PBR 220

1.20

38

UBR-PBR 320

1.20

UBR-PBR 320

2.20

(a) This flexible waveguide is used with antennas diameters up to 0.80m


(b) This flexible waveguide is used with antennas diameters 1.2 m
(c) Special (UBR) flange

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 48

NOT INTEGRATED SYSTEM (XD FlexiPacket Radio)


SOLUTION WITH ELLIPTICAL WAVEGUIDE
CONNECTION for SINGLE POLARIZATION
Note: This solution is not the standard solution. It is available on demand.

P
"E" BEND 90 g
(NB1)

U
VERTICAL
POLARIZATION

U
P

TWIST

(NB1)
"E" BEND 90 g
(NB1)

U
U
P
P

HORIZONTAL
POLARIZATION

WAVEGUIDE
SUPPORT (NB1)

75115mm POLE
(recommended 115mm)
1+0 VERTICAL FRAME
or
e

UNIVERSAL CLAMP
and RUBBBER BUSH
(NB1)

1+1 SUPPORTING FRAME

SUPPORTING FRAME WITH PASSING HOLE


USE ONLY THE SCREWS SUPPLIED
WITH THE WAVGUIDE CONNECTOR

U
or

PRESSURIZABLE FLANGE

UNPRESSURIZABLE FLANGE

SUPPORTING FRAME WITH BLIND HOLE


USE ONLY THE SCREWS SUPPLIED WITH THE
SUPPORTING FRAME

When the ODUs must be installed inside a shelter or equipment room, the waveguide must be connected to ground before
entering inside the shelter or equipment room.
For the waveguide pressurization See sheet 51.

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 49

NOT INTEGRATED SYSTEM (FH FlexiPacket Radio)


SOLUTION WITH ELLIPTICAL WAVEGUIDE
CONNECTION for SINGLE POLARIZATION
Note: This solution is not the standard solution. It is available on demand.

"E" BEND 90

VERTICAL
POLARIZATION

(NB1)
TWIST
(NB1)
"E" BEND 90
(NB1)

HORIZONTAL
POLARIZATION
48115mm POLE
(recommended 115mm)

UNIVERSAL CLAMP
and RUBBBER BUSH
(NB1)

WAVEGUIDE
SUPPORT (NB1)

1+0 FRAME NOT INTEGRATED SYSTEM


or
1+1 FRAME NOT INTEGRATED SYSTEM

PRESSURIZABLE FLANGE

USE ONLY THE SCREWS SUPPLIED


WITH THE WAVEGUIDE CONNECTOR

UNPRESSURIZABLE FLANGE

When the ODUs must be installed inside a shelter or equipment room, the waveguide must be connected to ground before
entering inside the shelter or equipment room.
For the waveguide pressurization See sheet 51.

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 50

NOT INTEGRATED SYSTEM


SOLUTION WITH ELLIPTICAL WAVE GUIDE
PRESSURIZATION WITH EXTERNAL DEHYDRATOR

Note: This solution is not the standard solution. It is available on demand.

WAVEGUIDE CONNECTOR
ODU SIDE

EXTERNAL DEHYDRATOR
90 GAS
INLET

Note: It is recommended for waveguide run over: 16 m (15 GHz), 25 m (18 GHz)

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 51

NOT INTEGRATED SYSTEM


SOLUTION WITH ELLIPTICAL WAVE GUIDE
Note: This solution is not the standard solution. It is available on demand.

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 52

OUTDOOR ASSEMBLY (XD FlexiPacket Radio)


ASSEMBLY ON SUPPORT FRAME

GROUND CABLE

XD FlexiPacket Radio
(See sheet 54)

IN/OUT ETHERNET
CABLE

PS CABLE

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 53

OUTDOOR ASSEMBLY (XD FlexiPacket Radio)


DIMENSION

168 mm

238 mm

238 mm

SIDE VIEW

124 mm
REAR VIEW

TOP VIEW

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 54

OUTDOOR ASSEMBLY (FH FlexiPacket Radio)


ASSEMBLY ON ALIGNMENT UNIT

FH alignment unit

FH FlexiPacket Radio
(See sheet 56)

Ground cable

PS cable

IN/OUT Ethernet cable

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 55

OUTDOOR ASSEMBLY (FH FlexiPacket Radio)


DIMENSION

237.8

168.46

237.8

124.1

FRONT VIEW

SIDE VIEW

TOP VIEW
REAR VIEW
Detail

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 56

OUTDOOR ASSEMBLY (XD and FH FlexiPacket Radio)


EXTERNAL CONNECTORS

IN/OUT ETHERNET
CABLE CONNECTOR
(See Sheets 58 and 59)

PS CONNECTOR
(See Sheets 60 and 61)

AGC CONNECTOR
(See Sheet 62)

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

GROUND BOLT
(See Sheet 63)

Sheet 57

OUTDOOR ASSEMBLY (XD and FH FlexiPacket Radio)


IN/OUT ETHERNET CABLE CONNECTOR

IN/OUT ETHERNET
CABLE CONNECTOR
Front view

LEMO multipolar connector with 8 golden power pins (24 AWG).

Ethernet connector pin function


Pin #

Pair

3 (white/green)

3 (green)

2 (white/orange)

2 (orange)

1 (white/blue)

1 (blue)

4 (white/brown)

4 (brown)

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 58

OUTDOOR ASSEMBLY (XD and FH FlexiPacket Radio)


IN/OUT ETHERNET CABLE

Max. length: 100 m

Ethernet cable
(P/N T555ETCB.23)

8-pin Lemo connector


(P/N T555ETLE.08)

Ethernet cable connection


Outdoor side: male shielded LEMO multipolar connector with 8 golden power pins (24 AWG).
Indoor side: terminated with a shielded RJ45.
The cable is double shielded, four twisted pairs, Cat 5e. In order to minimize the power loss in the cable, the
minimum required value for the AWG is 24. Cable materials are designed for outdoor conditions. The cable
shield shall be connected to the FlexiPacket Radio grounding point.
Lemo connector
Pin #

RJ45 connector

Pair

Pin #

Pair

3 (white/green)

3 (white/green)

3 (green)

3 (green)

2 (white/orange)

2 (white/orange)

2 (orange)

1 (blue)

1 (white/blue)

1 (white/blue)

1 (blue)

2 (orange)

4 (white/brown)

4 (white/brown)

4 (brown)

4 (brown)

Note: To terminate the Ethernet cable, use the special crimping tool (refer to sheet 123).

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 59

OUTDOOR ASSEMBLY (XD and FH FlexiPacket Radio)


PS CONNECTOR

PS CABLE CONNECTOR
Front view

LEMO multipolar connector with 2 golden power pins. (13 AWG).

PS connector pin function


Pin number

Signal name

Note

A1

Battery +

Internally this pin is floating. During


installation can be grounded or not.

A2

Battery -

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 60

OUTDOOR ASSEMBLY (XD and FH FlexiPacket Radio)


ODU PS CABLE

PS cable
(P/N T555PSCB.13)

2-pin Lemo connector


(P/N T555PSLE.02)

Max. length: 100 m

PS cable connections
Outdoor side: male shielded LEMO multipolar connector with 2 golden power pins 13 AWG).
Indoor side: terminate the cable on the battery or on the repeater.
Use a 3A circuit breaker in the indoor side of the cable.

Breaker

Battery

(see Note)

3A

BLUE

-48 Vdc

BROWN

Return

Battery Battery +
.

Pin number

Signal name

Note

Color wire

A1

Battery +

Internally this pin is floating.


During installation can be
grounded or not.

Brown

A2

Battery -

Blue

Note: The breaker must be installed in the Power Distribution Box.


Note: To terminate the PS cable, use the special crimping tool (refer to sheet 123 ).

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 61

OUTDOOR ASSEMBLY (XD and FH FlexiPacket Radio)


ACG CONNECTOR FOR FINE ALIGNMENT

ACG CONNECTOR
Front view

Female BNC 50 ohm, IP65 waterproof connector

RSSI parameters
Parameters

Value

Output voltage range and


Received Power range

-0.5V @ Prx = -90 dBm


-4.0V @ Prx = -20dBm

Output impedance

100 ohm / 1nF

Nominal sensitivity

0.5V/10dB

Accuracy

3 dB

Multimeter

Fine alignment check the DC voltage meter readings

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 62

OUTDOOR ASSEMBLY (XD and FH FlexiPacket Radio)


GROUND BOLT AND GROUND CABLE

1x6 mm PVC Ye-Gr


grounding cable

Uninsulated tube terminal


2
for 6 mm cable

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 63

OUTDOOR ASSEMBLY (XD and FH FlexiPacket Radio)


POLARIZATION APPLICATION

VERTICAL
POLARIZATION

REAR VIEW

HORIZONTAL
POLARIZATION

REAR VIEW

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 64

ETHERNET CABLE AND POWER SUPPLY CABLE CONNECTIONS


GROUNDING CONNECTIONS

Note: Q.ty 2 for each Eth or PS cables (ODU and IDU sides grounding). In addition: q.ty 1 each 30m cable length
after the first 40m, both for Eth and PS cables.
Note: For the grounding kit installation it is recommended to use the especial cable stripper (refer to sheet 123).
Note: The bending radius must be in accordance with the cable specification.

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 65

ETHERNET CABLE AND POWER SUPPLY CABLE CONNECTIONS


POLE FIXING OF THE GROUNDING PLATE KIT

a) These materials are included in P/N 332-309/91


b) The materials in the picture are shown as example. If required must be separately provided.

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 66

ETHERNET CABLE AND POWER SUPPLY CABLE CONNECTIONS


TYPICAL FIXING

Ethernet cable and Power Supply cable

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 67

FlexiPacket Hub A-2200


RACK ASSEMBLY

E1/T1 Patch panel


(a)

2013/2200/2200

66.5

FlexiPacket Hub A-2200

19/23/N3 ETSI Rack

565/600/600
500/300/300

a) The E1/T1 Patch panel is present in 16/32 E1/T1 configuration.

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 68

FlexiPacket Hub A-2200


GROUNDING CONNECTIONS

TO
STATION
EARTHING SYSTEM

(a)

YE-GR PVC 1x25mm


Grounding cable

M4x8 cylindrical
head screw
Grounding cable
2
(6mm L=400)

M4x8 cylindrical head screw

a) This cable is included in the 19"/23/N3 ETSI rack.

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 69

FlexiPacket Hub A-2200


INSTALLING THE DEVICE IN A 19-INCH RACK
(STANDARD SOLUTION)

Mounting brackets to
both sides of the device

Flat-head screws

(a)

19-inch
(a)
mounting bracket

19-inch rack

screws

(b)

a) These accessories are included in the A-2200 19-inch rack mounting kit, delivered with the FlexiPacket Hub
A-2200 chassis.
b) These screws are not supplied by Nokia Siemens Networks.

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 70

FlexiPacket Hub A-2200


INSTALLING THE DEVICE IN AN ETSI RACK
(OPTION ON REQUEST)

Mounting brackets to
both sides of the device

Flat-head screws (a)

N3 (Etsi) rack
(a)
mounting bracket

N3 (Etsi) rack

screws

(b)

a) These accessories are included in the A-2200 N3 (21 ETSI) rack mounting kit, ordered separately
(P/N AT22421-00-AA-S).
b) These screws are not supplied by Nokia Siemens Networks.

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 71

FlexiPacket Hub A-2200


INSTALLING THE DEVICE IN A 23-INCH RACK
(OPTION ON REQUEST)

Mounting brackets to both sides


of the device

Flat-head screws (a)

23-inch rack
(a)
mounting bracket

23-inch rack

screws

(b)

a) These accessories are contained in the A-2200 23-inch rack mounting kit (AT22402-00-AA-S), ordered
separately (P/N AT22402-00-AA-S).
b) These screws are not supplied by Nokia Siemens Networks.

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 72

FlexiPacket Hub A-2200


INSTALLING THE DEVICE ON A WALL

Mounting brackets to both sides


of the device

Wall
(a)
mounting bracket

Anchor and screw (b)

Flat-head
screws

(a)

a) These accessories are contained in the A-2200 Wall mounting kit, ordered separately
(P/N AT22403-00-AA-S).
b) The anchors and screws are not supplied by Nokia Siemens Networks.

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 73

FlexiPacket Hub A-2200


INSTALLING THE PATCH PANEL
The patch panel is delivered with brackets for 19-inch rack installation pre-installed. A mounting kit containing
two additional brackets with screws can be ordered separately. The two mounting brackets included in the kit
enable either 23-inch rack, ETSI rack, or wall installation.

screw

(b)

19-inch rack

(a)

N3/23-inch rack
mounting bracket

(a)

Attaching the mounting


brackets to patch panel
for wall installation

a) These accessories are contained in the A-2200 Patch Panel 23-inch Rack Mount kit, ordered separately
(P/N AT22404-00-AA-S).
b) These screws are not supplied by Nokia Siemens Networks.

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 74

(a)

FlexiPacket Hub A-2200


EQUIPMENT COMPOSITION

Fan tray

TIC (TDM Interface Card) bay

Main Unit

F
A

Power
supply bays

Access module bays

10-port 100/1000BASE-FX
optical fiber access module

Front-facing AC
power supply

8-port 10/100/1000BASE-T
copper cable access module

Front-facing DC
power supply

16-port E1/T1 CES


access module

8-port TIC

8-port E1/T1 CES


access module

32-port TIC

Blank faceplate

4 Ports OC3/STM1 CES


access module

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 75

FlexiPacket Hub A-2200


EQUIPMENT COMPOSITION TABLE

Ref.
layout

Descripition

P/N

A-2200 Extended temperature supported Carrier


Ethernet Edge Switch Base System (RoHS)

AT23000-00-AC-S

A-2200 PS AC, ETSI Front Entry

AT22034-00-AA-S

Note

Ref.

This item includes:


- Shelf
- Main unit,
- 19 Rack mounting kit.
- Fan tray
- Console cable

Sheet 78,
Sheet 79,
Sheet 80,
Sheet 82,
Sheet 83,
Sheet 84
Sheet 78

or

A-2200 PS DC, ETSI Front Entry

AT22038-00-AA-S

A-2200 PS AC, ETSI Front Entry

AT22034-00-AA-S

Sheet 78
Sheet 78
or

A-2200 PS DC, ETSI Front Entry

AT22038-00-AA-S

Sheet 78

A-2200 10-port 100/1000Base-FX Access Module


supporting extended temperature range (RoHS)

AT23110-00-AC-S

Sheet 84,
Sheet 85

A-2200 8-port 10/100/1000Base-T Access Module


with Sync Eth. Supporting extended temperature
range (RoHS)

AT23108-00-AB-S

A-2200 16-port T1/E1 CES Access Module


supporting extended temperature range

AT23216-00-AC-S

A-2200 10-port 100/1000Base-FX Access Module


supporting extended temperature range (RoHS)

AT23110-00-AC-S

A-2200 8-port 10/100/1000Base-T Access Module


with Sync Eth. Supporting extended temperature
range (RoHS)

AT23108-00-AB-S

A-2200 16-port T1/E1 CES Access Module


supporting extended temperature range

AT23216-00-AC-S

A-2200 8-port T1/E1 CES Access module supporting


extended temperature range

AT23208-00-AC-S

or

A-2200 4 Ports OC3/STM1 CES Access Module,


single slot size, supporting extended temperature
range

AT23314-00-AA-S

or

Sheet 92

A-2200 8-port T1/E1 TIC Module supporting


extended temperature range, RJ-45 termination

AT23408-00-AA-S

or

Sheet 89

A-2200 32-port T1/E1 TIC Module supporting


extended temperature range

AT23132-00-AA-S

or

Blank faceplate

or
Sheet 86
or

requires 32 T1/E1 TIC

Sheet 90,
Sheet 91
Sheet 84,
Sheet 85

or
Sheet 86
or

requires 32 T1/E1 TIC

Sheet 90,
Sheet 91

requires 8 T1/E1 TIC

Sheet 89

requires one on two 16port T1/E1 Patch Panel


( 16 or 32 T1/E1
configuration)

Sheet 90,
Sheet 91

used if no unit is required

A-2200 Rack mounting kit, 23

AT22402-00-AA-S

A-2200 Rack mounting kit, N3 21 ETSI

AT22421-00-AA-S

A-2200 Wall mounting kit

AT22403-00-AA-S

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 76

FlexiPacket Hub A-2200


E1/T1 PATCH PANEL

Ref.
layout
X

Descripition

P/N

A-2200 16-port T1/E1 Patch Panel supporting extended


temperature range

AT23416-00-AA-S

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Note

Ref

quantity 1 - in the 16
T1/E1 configuration

Sheet 90

quantity 2 - in the 32
T1/E1 configuration

Sheet 91

Sheet 77

FlexiPacket Hub A-2200


MAIN UNIT FUNCTIONS

1000Base-X Network Ports and LEDS

Dry contact connector

Ref.
Dry Contact
Connector
1000Base-X
Network Ports
and LEDS
Management
Ports

Management ports

Descripition
26-pin dry contact connector for alarm indicators

SPF ports 1000Base interfaces

Management ports:
One RS-232 console port
Two USB ports (to be supported in future releases)
One 10/100 Base-TX out-of-band management port

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 78

FlexiPacket Hub A-2200


MAIN UNIT - 1000BASE-X NETWORK PORTS CONNECTIONS (1)

LC connector

(a)

SPF Optical module


(see table to sheet 81)

OPTICAL Patch-Cord
(see table to sheet 81)

Port
Link 1 to 4

Descripition
SPF ports for module 1000Base-FX fiber interfaces

a) These materials are supplied with the installation materials.

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 79

FlexiPacket Hub A-2200


MAIN UNIT - 1000BASE-X NETWORK PORTS CONNECTIONS (2)

(a)

(a)

RJ45 Shielded
connector
SPF Electrical module
(see table to sheet 81)

4x2xAWG26
Cat 5e Cable

GbEth
PIN

(1000 Base T)

(10 Base T/100Base Tx)

Bi-directional Data pair A wire b

DATA Tx wire b

Bi-directional Data pair A wire a

DATA Tx wire a

Bi-directional Data pair B wire b

DATA Rx wire b

Bi-directional Data pair B wire a

NOT USED

Bi-directional Data pair C wire b

NOT USED

Bi-directional Data pair C wire a

DATA Rx wire a

Bi-directional Data pair D wire b

NOT USED

Bi-directional Data pair D wire a

NOT USED

a) These materials are supplied with the installation materials (refer to sheet 122).
Note: To terminate the Ethernet cable use the special crimping tool (refer to sheet 123).

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 80

FlexiPacket Hub A-2200 HW


MAIN UNIT - 1000BASE-X NETWORK PORTS CONNECTIONS (3)

Gigabit Ethernet SFP module


Descripition

P/N

SFP GE DDM 1000Base-SX 500m 850nm LC

AT10005-ID-R

SFP GE DDM 1000Base-LX 10km 1310nm LC

AT10006-ID-R

SFP GE DDM 1000Base-LH 70km 1550nm LC

AT10007-ID-R

SFP GE DDM 1000Base-LH 120km 1550nm LC

AT10012-0D-R

SFP GE DDM 1000Base-LH 50km 1550nm LC

AT10027-ID-R

SFP GE 1000Base-T Copper RJ-45

AT10037-R

STM1 SFP module


Descripition

P/N

SFP FE/STM1/OC-3 DDM 15km 1310nm LC

AT10014-ID-R

SFP FE/STM1/OC-3 DDM 40km 1310nm LC

AT10015-ID-R

SFP FE/STM1/OC-3 DDM 80km 1550nm LC

AT10016-ID-R

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 81

FlexiPacket Hub A-2200


MAIN UNIT CONSOLE PORT CONNECTION

JACK
(Equipment side)

It is included with
the base system

RJ45 connector

DB-9 connector

Console cable pin assignments


PC side (DB-9)

A-2200 side (RJ45)

2 (RX)

3 (TX)

3 (TX)

6 (RX)

8 (CTS)

7 (RTS)

7 (RTS)

8 (CTS)

5 (CGND)

4, 5 (CGND)

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 82

lexiPacket Hub A-2200


MAIN UNIT MANAGEMENT PORT CONNECTION

JACK
(Equipment side)

LAN cable

10/100BASE-TX cable pin assignments


PIN

Type

Signal

Input

RX+

Input

RX-

n/a

n/a

Output

TX+

Output

TX-

n/a

n/a

n/a

n/a

n/a

n/a

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 83

FlexiPacket Hub A-2200


MAIN UNIT - ALARMS INTERFACE CONNECTIONS

Dry contact port pin assignment


Pin

A-2200 Alarm Cable


(P/N AT22407-00-AA-S)

Cable Color

Signal

Black

Warning Normally Closed

Brown

Minor Normally Closed

Red

Major Normally Closed

Light green

Critical Normally Closed

Yellow

Not Connected

Green

Not Connected

Black/white

Not Connected

Purple

Alarm In 3

Brown/white

Dry In Alarm Reference

10

White

Warning Alarm Common

11

Pink

Minor Alarm Common

12

Orange

Major Alarm Common

13

Blue

Critical Alarm Common

14

Gray

Not Connected

15

Red/white

Not Connected

16

Orange/white

Not Connected

17

Green/white

Alarm In 4

18

Blue/white

Alarm In 1

19

Purple/white

Warning Normally Open

20

Red/black

Minor Normally Open

21

Orange/black

Major Normally Open

22

Pink/red

Critical Normally Open

23

Green/black

Not Connected

24

Gray/black

Not Connected

25

Pink/black

Not Connected

26

Yellow/black

Alarm In 2

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 84

FlexiPacket Hub A-2200


10-PORT 100/1000BASE-FX OPTICAL FIBER ACCESS MODULE CONNECTIONS (1)
Note: This module cannot be used to connect the FlexiPacket Radio.

D1

E1

LC connector

(a)

SPF Optical module


(see table to sheet 87)

OPTICAL Patch-Cord
(see table to sheet 87)

Port
Link 2 to 8

Descripition
SPF ports for module 100/1000Base-FX fiber interfaces

a) These materials are supplied with the installation materials.

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 85

FlexiPacket Hub A-2200


10-PORT 100/1000BASE-T OPTICAL FIBER ACCESS MODULE CONNECTIONS (2)
Note: This module cannot be used to connect the FlexiPacket Radio.

D1

E1
Port 1
SPF electrical module ONLY

(a)

(a)

RJ45 Shielded
connector
(P/N 422-053/63)
SPF Electrical module
(see table to sheet 87)

4x2xAWG26
Cat 5e Cable
(P/N 106-041/76)

GbEth
PIN

(1000 Base T)

(10 Base T/100Base Tx)

Bi-directional Data pair A wire b

DATA Tx wire b

Bi-directional Data pair A wire a

DATA Tx wire a

Bi-directional Data pair B wire b

DATA Rx wire b

Bi-directional Data pair B wire a

NOT USED

Bi-directional Data pair C wire b

NOT USED

Bi-directional Data pair C wire a

DATA Rx wire a

Bi-directional Data pair D wire b

NOT USED

Bi-directional Data pair D wire a

NOT USED

a) These materials are supplied with the installation materials.


Note: To terminate the Ethernet cable use the special crimping tool (refer to sheet 123).

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 86

FlexiPacket Hub A-2200


10-PORT 100/1000BASE-FX OPTICAL FIBER ACCESS MODULE CONNECTIONS (3)

Gigabit Ethernet SFP module


Descripition

P/N

SFP GE DDM 1000Base-SX 500m 850nm LC

AT10005-ID-R

SFP GE DDM 1000Base-LX 10km 1310nm LC

AT10006-ID-R

SFP GE DDM 1000Base-LH 70km 1550nm LC

AT10007-ID-R

SFP GE DDM 1000Base-LH 120km 1550nm LC

AT10012-0D-R

SFP GE DDM 1000Base-LH 50km 1550nm LC

AT10027-ID-R

SFP GE 1000Base-T Copper RJ-45

AT10037-R

STM1 SFP module


Descripition

P/N

SFP FE/STM1/OC-3 DDM 15km 1310nm LC

AT10014-ID-R

SFP FE/STM1/OC-3 DDM 40km 1310nm LC

AT10015-ID-R

SFP FE/STM1/OC-3 DDM 80km 1550nm LC

AT10016-ID-R

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 87

FlexiPacket Hub A-2200


8-PORT 10/100/1000BASE-T COPPER CABLE ACCESS MODULE CONNECTIONS

D2

E2
Port #8

JACK
(Equipment side)

LCT

JACK
(Equipment side)

4x2xAWG26
Cat 5e Cable

Port

(a)

Descripition

Connector type

10/100/1000Base-T copper interfaces

Link 1 to 8

RJ45

10/100/1000BASE-T cable pin assignments


PIN

(1000 Base T)

(10 Base T/100Base Tx)

Bi-directional Data pair A wire b

DATA Tx wire b

Bi-directional Data pair A wire a

DATA Tx wire a

Bi-directional Data pair B wire b

DATA Rx wire b

Bi-directional Data pair B wire a

NOT USED

Bi-directional Data pair C wire b

NOT USED

Bi-directional Data pair C wire a

DATA Rx wire a

Bi-directional Data pair D wire b

NOT USED

Bi-directional Data pair D wire a

NOT USED

a) This cable is supplied terminated at both ends with the installation materials (refer to sheet 122).

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 88

FlexiPacket Hub A-2200


8-PORT E1/T1 CONFIGURATION

see note (b)

E4

F1

(a)

Port
1 to 8

Description
T1/E1 interface

Connector type
RJ48

a) Connection details are provided on sheet 92.


b) 8-port CES services are implemented by installing an access module, which enables E1/T1 functionality,
and a TDM Interface Card (TIC) which enables 8 E1/T1 interfaces.
When an 8-port TIC is used, the 8-port CES access module must be installed in the right-most access bay
ONLY.

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 89

FlexiPacket Hub A-2200


16-PORT E1/T1 CONFIGURATION

X
see note (b)

F2

E3
Champ cable
(supplied with the patch panel)

Ports 1 to 4
(a)

Port
1 to 16

Ports 5 to 8
(a)

Ports 9 to 12
(a)

Description
T1/E1 interface

Ports 13 to 16
(a)

Connector type
RJ48

a) Connection details are provided on sheet 92.


b) 16-port CES services are implemented by installing an access module, which enables E1/T1 functionality.
A TIC is installed together with a patch panel, enabling 16 E1/T1 interfaces.

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 90

FlexiPacket Hub A-2200


32-PORT E1/T1 CONFIGURATION

X
Patch panel 1

X
Patch panel 2

F2

see note (b)

D3

E3
Champ cable
(supplied with the patch panel)

Patch panel 1

Ports 1 to 4

Ports 5 to 8

Ports 9 to 12

Ports 13 to 16

Patch panel 2

Ports 17 to 20
(a)

Ports 21 to 24
(a)

Ports 25 to 28
(a)

Ports 29 to 32
(a)

Patch Panel 1

Patch Panel 2

Ports

Ports

1 to 16

17 to 32

Description
T1/E1 interface

Connector type
RJ48

a) Connection details are provided on sheet 92.


b) 32-port CES services are implemented by installing two access modules, which enable E1/T1 functionality.
A TIC is installed together with two patch panels, enabling 32 E1/T1 interfaces.

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 91

FlexiPacket Hub A-2200 HW


E1/T1 CONNECTION

RJ48 Port (E1/T1)

RJ48 connector

E1 cable - 120 Ohm

(a)

JACK
(Equipment side)

T1/E1 pin assignments


PIN

Type

Signal

Input

RX+

Input

RX-

n/a

n/a

Output

TX+

Output

TX-

n/a

n/a

n/a

n/a

n/a

n/a

a) These materials are supplied with the installation materials (refer to sheet 122).

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 92

FlexiPacket Hub A-2200


OC3/STM1 CES ACCESS MODULE CONNECTIONS

D5

Port

E5

Descripition

Type

Signal

Connector
type

TX 1

STM1 electrical interface

Input

Tx

BNC

RX 1

STM1 electrical interface

Output

Rx

BNC

TX 2

STM1 electrical interface

Input

Tx

BNC

RX 2

STM1 electrical interface

Output

Rx

BNC

TX 3

STM1 electrical interface

Input

Tx

BNC

RX 3

STM1 electrical interface

Output

Rx

BNC

TX 4

STM1 electrical interface

Input

Tx

BNC

RX 4

STM1 electrical interface

Output

Rx

BNC

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 93

FlexiPacket Hub A-2200


FRONT -FACING AC POWER SUPPLY CONNECTION

AC Power Cord

P/N

AC Power cords description

AT20089-00-AA

A-12XX/2000 Power Cord,USA

AT20089-01-AA

A-12XX/2000 Power Cord,EUR

AT20089-02-AA

A-12XX/2000 Power Cord,JPN

AT20089-03-AA

A-12XX/2000 Power Cord,UK

AT20089-04-AA

A-12XX/2000 Power Cord,SWI

AT20089-05-AA

A-12XX/2000 Power Cord,DNK

AT20089-06-AA

A-12XX/2000 Power Cord,IL

AT20089-07-AA

A-12XX/2000 Power Cord,INDIA

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 94

FlexiPacket Hub A-2200


FRONT -FACING DC POWER SUPPLY CONNECTION

Power Supply
Cable 2x1.5mm

DC PSU connector
(delivered with the
power supply unit)
RECOMMENDED WIRING
P/N

Station
Breaker

Description

Power Supply Return

-48 Vdc nominal 10%

4A

Power
connector
BLUE

Return
-48 Vdc

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

RED

2
1

Sheet 95

FlexiPacket Hub A-2200 HW


CABLE TRAYS

Top position tray

Fiber or cable

Fiber or cable

P/N

Bottom position tray

Description

AT22406-00-AA-S

A-2200 Rack Fiber Tray, 19"

AT22406-00-AA-S

A-2200 Rack Fiber Tray, 23"

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 96

FlexiPacket Hub A-1200


Modular version in RACK ASSEMBLY

43.6

2013/2200/2200

445

FlexiPacket Hub A-1200 Modular

19/23/N3 ETSI Rack

565/600/600
500/300/300

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 97

FlexiPacket Hub A-1200


Fixed version in RACK ASSEMBLY

66.5

2013/2200/2200

330

FlexiPacket Hub A-1200 Fixed

19/23/N3 ETSI Rack

565/600/600
500/300/300

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 98

FlexiPacket Hub A-1200


GROUNDING CONNECTIONS

TO
STATION
EARTHING SYSTEM

(a)

YE-GR PVC 1x25mm


Grounding cable

M4x8 cylindrical head screw

Grounding cable
2
(6mm L=400)

M4x8 cylindrical head screw

Alternative Grounding Point on rear side

a) This cable is included in the 19"/23/N3 ETSI rack.


FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 99

FlexiPacket Hub A-1200


INSTALLING THE DEVICE IN A 19-INCH RACK
(STANDARD SOLUTION)

Mounting brackets to both


sides of the device

Flat-head screws

(a)

19-inch
(a)
mounting bracket
Note:
In this figure is shown the
MODULAR VERSION only
19-inch rack

screws

(b)

a) These accessories are included in the A-1200 19-inch rack mounting kit, delivered with the FlexiPacket Hub
(Modular or Fixed version) A-1200 chassis.
b) These screws are not supplied by Nokia Siemens Networks.

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 100

FlexiPacket Hub A-1200


INSTALLING THE DEVICE IN AN ETSI RACK
(OPTION ON REQUEST)

Mounting brackets to
both sides of the device

Flat-head screws (a)

N3 (Etsi) rack
(a)
mounting bracket
Note:
In this figure is shown the
MODULAR VERSION only
N3 (Etsi) rack

screws

(b)

a) These accessories are included in the A-1200 N3 (21 ETSI) rack mounting kit, ordered separately
(P/N AT12406-00-AA-S for Modular version) or (P/N AT12408-00-AA-S for Fixed version).
b) These screws are not supplied by Nokia Siemens Networks.

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 101

FlexiPacket Hub A-1200


INSTALLING THE DEVICE IN A 23-INCH RACK
(OPTION ON REQUEST)

Flat-head screws (a)

Mounting brackets to both sides


of the device

Note:
In this figure is shown the
MODULAR VERSION only

23-inch rack
(a)
mounting bracket

23-inch rack

screws

(b)

a) These accessories are contained in the A-1200 23-inch rack mounting kit, ordered separately
(P/N AT12402-00-AA-S for Modular version) or (P/N AT12403-00-AA-S for Fixed version).
b) These screws are not supplied by Nokia Siemens Networks.

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 102

FlexiPacket Hub A-1200


INSTALLING THE DEVICE ON A WALL

Mounting brackets to both sides


of the device

Wall
(a) mounting bracket

(b)

(a)

Anchor and screw

Flat-head
screws

Note:
In this figure is shown the
MODULAR VERSION only

a) These accessories are contained in the A-1200 Wall mounting kit, ordered separately
(P/N AT12404-00-AA-S for Modular or Fixed version).
b) The anchors and screws are not supplied by Nokia Siemens Networks.

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 103

FlexiPacket Hub A-1200


EQUIPMENT COMPOSITION

FIXED VERSION
Fan tray

Main Unit

MODULAR VERSION
Fan tray

Module (Optional)

Main Unit

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 104

FlexiPacket Hub A-1200


EQUIPMENT COMPOSITION TABLE

Ref.
layout

Descripition

P/N

Note

Ref.

A-1200/FPH FIXED SWITCH DC ET

AT12002-00-AC-S

This item includes:


- Shelf
- Main unit,
- 19 Rack mounting kit.
- Fan tray
- Console cable

Sheet 106

A-1200/FPH MODULAR SWITCH DC ET

AT12003-00-AC-S

This item includes:


- Shelf
- Main unit,
- 19 Rack mounting kit.
- Fan tray
- Console cable

Sheet 107

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 105

FlexiPacket Hub A-1200


FIXED VERSION - MAIN UNIT FUNCTIONS

100/1000Base-FX SFP
Network Ports and LEDS

E1/T1 PORTS

10/100/1000Base-T
Network Ports and LEDS

Management ports

Ref.
Dry Contact Connector

26-pin dry contact connector for alarm indicators

2 SFP ports 1000Base-X Optical interfaces

10/100/1000Base-T
Network Ports
and LEDS

6-port s 10/100/1000Base-T copper interfaces

Management Ports

DC Power connector

DC Power
Connector

Descripition

100/1000Base-X
Network Ports and
LEDS

E1/T1 Ports

Dry contact connector

8-ports E1/T1 interfaces


Management ports:
One RS-232 console port
One USB ports (to be supported in future releases)
One 10/100 Base-TX out-of-band management port
2 DC Power Connector

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 106

FlexiPacket Hub A-1200


MODULAR VERSION - MAIN UNIT FUNCTIONS

100/1000Base-FX SFP
Network Ports and LEDS

E1/T1 PORTS

10/100/1000Base-T
Network Ports and LEDS

Management ports

Ref.
Dry Contact Connector

Dry contact connector

Descripition
26-pin dry contact connector for alarm indicators

100/1000Base-X
Network Ports and
LEDS

2/4 SFP ports 1000Base-X Electrical/Optical interfaces

10/100/1000Base-T
Network Ports
and LEDS

6-port s 10/100/1000Base-T copper interfaces

E1/T1 Ports

Management Ports

DC Power connector

DC Power
Connector

8-ports E1/T1 interfaces


Management ports:
One RS-232 console port
One USB ports (to be supported in future releases)
One 10/100 Base-TX out-of-band management port
2 DC Power Connector

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 107

FlexiPacket Hub A-1200


MAIN UNIT (FIXED VERSION) - 1000BASE-X NETWORK PORTS CONNECTIONS

LC connector

(a)

SPF Optical module


(see table to sheet 110)

OPTICAL Patch-Cord
(see table to sheet 110)

Port
1 and 2

Descripition
SPF ports for module 100/1000Base-FX fiber interfaces

a) These materials are supplied with the installation materials.

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 108

FlexiPacket Hub A-1200


MAIN UNIT (MODULAR VERSION) - 1000BASE-X NETWORK PORTS CONNECTIONS

LC connector

(a)

SPF Optical module


(see table to sheet 110)

OPTICAL Patch-Cord
(see table to sheet 110)

Port
1 to 4

Descripition
SPF ports for module 100/1000Base-FX fiber interfaces

a) These materials are supplied with the installation materials.

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 109

FlexiPacket Hub A-1200


MAIN UNIT - 1000BASE-X NETWORK PORTS CONNECTIONS

Gigabit Ethernet SFP module


Descripition

P/N

SFP GE DDM 1000Base-SX 500m 850nm LC

AT10005-ID-R

SFP GE DDM 1000Base-LX 10km 1310nm LC

AT10006-ID-R

SFP GE DDM 1000Base-LH 70km 1550nm LC

AT10007-ID-R

SFP GE DDM 1000Base-LH 120km 1550nm LC

AT10012-0D-R

SFP GE DDM 1000Base-LH 50km 1550nm LC

AT10027-ID-R

STM1 SFP module


Descripition

P/N

SFP FE/STM1/OC-3 DDM 15km 1310nm LC

AT10014-ID-R

SFP FE/STM1/OC-3 DDM 40km 1310nm LC

AT10015-ID-R

SFP FE/STM1/OC-3 DDM 80km 1550nm LC

AT10016-ID-R

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 110

FlexiPacket Hub A-1200


MAIN UNIT (MODULAR/FIXED VERSION) - CONSOLE PORT CONNECTION

JACK
(Equipment side)

It is included with
the base system

RJ45 connector

DB-9 connector

Console cable pin assignments


PC side (DB-9)

A-1200 side (RJ45)

2 (RX)

3 (TX)

3 (TX)

6 (RX)

8 (CTS)

7 (RTS)

7 (RTS)

8 (CTS)

5 (CGND)

4, 5 (CGND)

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 111

FlexiPacket Hub A-1200


MAIN UNIT (MODULAR/FIXED VERSION) - MANAGEMENT PORT CONNECTION

JACK
(Equipment side)

LAN cable

10/100BASE-TX cable pin assignments


PIN

Type

Signal

Input

RX+

Input

RX-

n/a

n/a

Output

TX+

Output

TX-

n/a

n/a

n/a

n/a

n/a

n/a

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 112

FlexiPacket Hub A-1200


MAIN UNIT (MODULAR/FIXED VERSION) - ALARMS INTERFACE CONNECTIONS

Dry contact port pin assignment


Pin

Cable Color

Signal

Black

Warning Normally Closed

Brown

Minor Normally Closed

Red

Major Normally Closed

Light green

Critical Normally Closed

Yellow

Not Connected

Green

Not Connected

Black/white

Not Connected

Purple

Alarm In 3

Brown/white

Dry In Alarm Reference

10

White

Warning Alarm Common

11

Pink

Minor Alarm Common

12

Orange

Major Alarm Common

13

Blue

Critical Alarm Common

14

Gray

Not Connected

15

Red/white

Not Connected

16

Orange/white

Not Connected

17

Green/white

Alarm In 4

18

Blue/white

Alarm In 1

19

Purple/white

Warning Normally Open

20

Red/black

Minor Normally Open

21

Orange/black

Major Normally Open

22

Pink/red

Critical Normally Open

23

Green/black

Not Connected

24

Gray/black

Not Connected

25

Pink/black

Not Connected

26

Yellow/black

Alarm In 2

A-2200 Alarm Cable


(P/N AT22407-00-AA-S)

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 113

FlexiPacket Hub A-1200


MAIN UNIT (FIXED VERSION) - PORTS 10/100/1000BASE-T COPPER CABLE INTERFACE CONNECTIONS

JACK
(Equipment side)

4x2xAWG26
Cat 5e Cable

Port

(a)

Descripition

Connector type

10/100/1000Base-T copper interfaces

3 to 8

RJ45

10/100/1000BASE-T cable pin assignments


PIN

(1000 Base T)

(10 Base T/100Base Tx)

Bi-directional Data pair A wire b

DATA Tx wire b

Bi-directional Data pair A wire a

DATA Tx wire a

Bi-directional Data pair B wire b

DATA Rx wire b

Bi-directional Data pair B wire a

NOT USED

Bi-directional Data pair C wire b

NOT USED

Bi-directional Data pair C wire a

DATA Rx wire a

Bi-directional Data pair D wire b

NOT USED

Bi-directional Data pair D wire a

NOT USED

a) This cable is supplied terminated at both ends with the installation materials (refer to sheet 122).

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 114

FlexiPacket Hub A-1200


MAIN UNIT (MODULAR VERSION) - PORTS 10/100/1000BASE-T COPPER CABLE INTERFACE
CONNECTIONS

JACK
(Equipment side)

4x2xAWG26
Cat 5e Cable

Port

(a)

Descripition

Connector type

10/100/1000Base-T copper interfaces

3 to 8

RJ45

10/100/1000BASE-T cable pin assignments


PIN

(1000 Base T)

(10 Base T/100Base Tx)

Bi-directional Data pair A wire b

DATA Tx wire b

Bi-directional Data pair A wire a

DATA Tx wire a

Bi-directional Data pair B wire b

DATA Rx wire b

Bi-directional Data pair B wire a

NOT USED

Bi-directional Data pair C wire b

NOT USED

Bi-directional Data pair C wire a

DATA Rx wire a

Bi-directional Data pair D wire b

NOT USED

Bi-directional Data pair D wire a

NOT USED

a) This cable is supplied terminated at both ends with the installation materials (refer to sheet 122).

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 115

FlexiPacket Hub A-1200


MAIN UNIT (MODULAR/FIXED VERSION) - PORTS E1/T1 INTERFACE CONNECTIONS

JACK
(Equipment side)

JACK
(Equipment side)

Port
1 to 8

Description
T1/E1 interface

Connector type
RJ48

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 116

FlexiPacket Hub A-1200


E1/T1 CONNECTION

RJ48 Port (E1/T1)

RJ48 connector

E1 cable - 120 Ohm

(a)

JACK
(Equipment side)

T1/E1 pin assignments


PIN

Type

Signal

Input

RX+

Input

RX-

n/a

n/a

Output

TX+

Output

TX-

n/a

n/a

n/a

n/a

n/a

n/a

a) These materials are supplied with the installation materials (refer to sheet 122).

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 117

FlexiPacket Hub A-1200


MAIN UNIT (MODULAR/FIXED VERSION) - DC POWER SUPPLY CONNECTION

Power Supply
Cable 2x1.5mm

DC PSU connector
(delivered with the
power supply unit)
RECOMMENDED WIRING
Connector

Pin

Description

Power Supply Return

-48 Vdc nominal 10%

Power Supply Return

-48 Vdc nominal 10%

Station
Breaker
4A

PWR A

Return

PWR B

PWR A
BLUE
RED

-48 VDC
Station
Breaker
4A

BLUE
RED

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

1
PWR B

Return
-48 VDC

2
1

Sheet 118

ACCESSORIES
FlexiPacket Radio CABLES

Product code

Product name

Notes

T555ETCB.23

Ethernet cable reel

CAT 5e 500m

T555PSCB.13

Power Supply cable reel

500m

T555GDOU.06

Grounding cable kit for FlexiPacket Radio Q.ty 1 for each Flexi-Packet Radio

T555GDCB.10

Grounding cable kit for Eth and PS

Q.ty 2 for each Eth or PS cables (ODU


and IDU sides ground-ing). In addition:
q.ty 1 each 30m cable lenght after the
first 40m, both for Eth and PS cables

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 119

ACCESSORIES
FlexiPacket Radio CABLES ACCESSORIES

Product code

Product name

Notes

T555TEKT.00

Cable tie for outdoor 74-220d (100 pcs)

STANDARD USE: quantity 1 piece for


0.3 meter for each cable. These cable
ties (to be used near the FlexiPacket
Radio) are mandatory

T555TEKT.01

Cable tie for outdoor 26-62d (100 pcs)

STANDARD USE: quantity 1 piece for


0.3 meter for each cable (to be used for
all the cable run)

T555CLKT.00

Clamp FIMO for 1 Eth + 1 PS cables


(50pcs)

OPTIONAL: (in alter-native to the cable


tie T555TEKT.01) order quantity 1 for 0.3
meter for max 1 IDU/ODU Eth + power
supply connections

T555CLKT.20

Clamp FIMO for 2 Eth + 2 PS cables


(50pcs)

OPTIONAL: (in alter-native to the cable


tie T555TEKT.01) order quantity 1 for 0.3
meter for max 2 IDU/ODU Eth + power
supply connections

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 120

ACCESSORIES
FlexiPacket Radio CONNECTORS

Product code

Product name

Notes

T555ETRJ.08

RJ45 connector for Ethernet cable

Order one for each FlexiPacket Radio

T555ETLE.08

Lemo connector for Ethernet cable

Order one for each FlexiPacket Radio

T555PSLE.02

Lemo connector for Power cable

Order if FlexiPacket Radio is supplied


through dedicated -48VDC interface, one
for each Flexi-Packet Radio

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 121

ACCESSORIES
FlexiPacket Hub CABLES

Product code

Product name

Notes

Grounding Cable
T555GDOU.06 Grounding cable for FlexiPacket Radio

Qty: one each Indoor Device

E1 cables

OPTIONAL (E1 interfaces are standard


RJ45 - quote if requested)

T55249.01

E1 CABLE (RJ48C CONNECTOR)


FIU19 4xRJ45 2m Cable 15 meters

Four cables 15meters each, with one


connector in one side. Qty: 1 each 4 E1
ports

T55252.01

FIU 19 4XRJ45 CONNECTOR KIT

Four connectors, use with T55249.01

RJ 45 CONNECTOR FOR LAN CABLE


RJ45 connector for Ethernet cable

Alternative solution to T55249.01 and


T55252.01

T555ETRJ.08
T36614.01

CABLE REEL E1/T1 120OHM 500m

LAN Cables

OPTIONAL

CS73199.05

LAN cable CAT6 S/FTP RJ45-RJ45 5m

Terminated cable at both ends

CS73199.10

LAN cable CAT6 S/FTP RJ45-RJ45 10m

Terminated cable at both ends

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 122

ACCESSORIES
CRIMP TOOLS

Crimping tools

Code

Description

T555ETTL.00
T555ETTL.01
T555ETTL.02

Crimp tool for Eth Lemo connector


Crimp positioner for Eth Lemo connector
Crimp extractor for Eth Lemo connector

T555PSTL.00
T555PSTL.01
T555PSTL.02

Crimp tool for PS Lemo connector


Crimp positioner for PS Lemo connector
Crimp extractor for PS Lemo connector

T555RJTL.00

Crimp tool for RJ45 connector

T555TETL.00

Crimp tool for cable tie

Note

Needed
Mandatory tools
for Lemos
connectors
crimping

Needed
Mandatory tools
or equivalent

Needed
Recommended
or equivalent
Tools
T555GDTL.00

Cable stripper for grounding cable

FlexiPacket Radio
Solution Site Installation Abstract
A25000-A1200-A031-02-76P1

Sheet 123