Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
com
Catalog HY15-3502/US
PAGE NO.
SUPER COILS
CC ............................................... 1/2 Solenoid Tubes ................................................................................... CE3-CE4
CA ............................................... 5/8 Solenoid Tubes ................................................................................... CE5-CE6
SH
LM
FC
Flow
Controls
ELECTRONICS
XPRO902 .................................... 12 VDC PWM Controller, 110Hz, 19W ................................................... CE17-CE18
XPRO932 .................................... 12 VDC PWM Controller, 110Hz, 30W ................................................... CE17-CE18
Load/Motor
Controls
STANDARD COILS
Unicoil ........................................ 1/2 Solenoid Tubes ................................................................................... CE7-CE8
Unicoil ........................................ 5/8 Solenoid Tubes ................................................................................. CE9-CE10
PC
Pressure
Controls
CV
Check
Valves
SERIES
Shuttle
Valves
Contents
DC
Directional
Controls
Manual
Valves
MV
XPRO904rid ............................... 24 VDC PWM Controller, 95-230Hz, 19W, Multi-adj. ............................. CE21-CE22
XPRO934rid ............................... 24 VDC PWM Controller, 95-230Hz, 30W, Multi-adj. ............................. CE21-CE22
SV
XPRO704b .................................. Soft Start and Stop Valve Controller, 12/24 VDC .............................................. CE24
PV
Proportional
Valves
Solenoid
Valves
XPRO704 .................................... Soft Start Valve Controller, 12/24 VDC ............................................................. CE23
Coils &
Electronics
CE
XPRO804 .................................... Power Saver Controller, 12/24 VDC PWM ........................................................ CE25
Bodies &
Cavities
BC
TD
Technical
Data
Logic
Elements
LE
XPRO902d .................................. 12 VDC PWM Controller, 95-230Hz, 19W .............................................. CE19-CE20
XPRO932d .................................. 12 VDC PWM Controller, 95-230Hz, 30W .............................................. CE19-CE20
Technical Tips
CV
INTRODUCTION
Check
Valves
SH
Shuttle
Valves
LM
Load/Motor
Controls
FC
This technical tips section is designed to help familiarize you with the Parker line of Coils. In this section we
highlight the features and discuss some of the available options. We also use this section to present some
common terminology related to coil and coil technology.
Flow
Controls
DC Windings
All coils are DC wound. An internal
full wave rectifier is added for AC
current, eliminating inrush current,
and allowing for voltage interchangeability.
Variety of Terminations
Coils are offered in a wide variety
of terminations, including integrally
molded connectors and voltages to
meet your system requirements.
PC
Pressure
Controls
LE
Logic
Elements
DC
Directional
Controls
MV
Low Carbon
Steel Frame
Zinc plated low
carbon steel frame
surrounds coil, increasing
flux density. Low carbon steel provides better
magnetic properties and greater permeability.
Manual
Valves
Diodes
Internally molded
diodes are available.
Polarity is molded into
coil for ease of installation.
SV
Solenoid
Valves
Ribbed Surface
External ridges
provide a larger
coil surface area, which
allows for better heat dissipation.
PV
Proportional
Valves
CE
Coils &
Electronics
BC
Bodies &
Cavities
TD
Technical
Data
CE1
Technical Tips
1.57
Non-Rectified
710549-00
710549-01
Rectified
712126-01
712126-00
.39
1.04
Shuttle
Valves
Load/Motor
Controls
PC
LE
DC
MV
SV
Solenoid
Valves
FC
Flow
Controls
LM
Pressure
Controls
Continuous duty does not mean the coil will have the
same amount of power after hours of operation as it
had at initial actuation. Coils do heat up during use.
This internal heat rise increases the resistance of the
coil and thus, decreases the current (V = IR). The
performance curves presented on the solenoid valve
pages are based on a coil at room temperature and
85% of voltage. Thus, when using a valve in continuous duty applications, you may need to derate the
performance. In short, the continuous duty rating
signifies that while the coil will get hot during use and
resistance will increase, it will not generate enough
heat to damage the coil.
SH
Logic
Elements
Voltages: Parker has a wide selection of coils available to meet your needs. Most coil terminations are
available with our standard voltages of 12V and 24V in
DC, and 120V and 240V in AC. Voltages 6V, 10V, 18V,
36V, 48V DC and 440V AC are also available for many
termination types at a slight premium. Contact your
Parker representative should your application call for
voltages other than our standard offering.
Directional
Controls
Manual
Valves
Below are some of the common options to the Unicoil product offering.
Check
Valves
COMMON OPTIONS
.06
1.04
Proportional
Valves
PV
Conduit
Conduit
Rectified
712704-00
2.45
Non-Rectified
710549-02
1.57
1.04
1.37
CE
Coils &
Electronics
1.04
BC
.06
1.06
.22
.22
1.04
Bodies &
Cavities
.06
TD
1.06
CE2
1.00
1.04
Technical
Data
Current Types: Both direct current (DC) and alternating current (AC) versions are available for the Parker
line of coils. The AC versions are essentially DC coils
with a full wave rectifier integrally molded into the coil.
The rectifiers are rated for voltage peaks up to 1000
volts maximum. For voltage transients greater than
1000 volts, a Harris Thyrector is recommended. The
AC coils operate at 50/60 cycles (Hz). Since the AC
versions are rectified
AC Coil Assembly
DC coils, there is
no inrush current
like with true
AC coils. It
also means
DC coils and
AC coils are
Voltage Surge
Suppressor (Thyrector)
interchangeable.
Features
Check
Valves
SH
Shuttle
Valves
LM
Load/Motor
Controls
FC
Flow
Controls
PC
Pressure
Controls
LE
Ordering Information
CC
Super Coil
1/2 I.D.
Specifications
Coil Type
S
P
Standard
Puissant
Nominal Wattage
(See Ordering
Information For
Exact Wattage)
S
P
14 Watts
19 Watts
Wattage
Voltage
Termination
Code Wattage
S
Standard
Puissant
Code
Voltage
Watts
Amps
Ohms**
S
P
Duty Cycle
010
10 VDC
14
19
1.38
1.90
Magnetic Wire
Insulation Class
012*
018
12 VDC
18 VDC
14
14
19
19
1.15
0.77
Temperature
Range
-40C to +200C
(-40F to +392F)
024*
24 VDC
14
19
0.58
Temperature
Rise At Nominal
Voltage And
Natural Ventilation
S
P
048
115*
48 VDC
115 VAC
14
16
19
19
0.29
0.17
230
230 VAC
17
22
0.09
0.12
Dielectric Strength
Maximum Current
Leakage (Amps)
Encapsulating
Material
PV
Proportional
Valves
Logic
Elements
Volts
Color Identification S
On The Terminal
P
Boss
CE
Weight
DC
Directional
Controls
MV
Manual
Valves
SV
75C (135F)
95C (172F)
*Standard Voltages
7.25
5.26
2596 1919
Code Termination
Solenoid
Valves
A
AD
C
*D
H
HE
*L
LS
LD
Black Ring
Red Ring
LE
PF
Coils &
Electronics
PM
AC Coil Assembly
*S
*W
WE
*Y
BC
Bodies &
Cavities
TD
Technical
Data
CE3
A - Amp Junior
AD - Amp Junior
with 3 Amp Diode
(+ and - metered)
13 (.52) I.D.
39.6
(1.56)
56.0
(2.21)
53.0
(2.07)
Y - Single Screw
LE - Double Lead
with 3 Amp Diode
(Internal ground)
8-32 UNC screw & nut
W - Double Screw
8-32 UNC screw & nut
(+ and - metered)
67.0
(2.62)
FC
PF - Female
Packard
Connector
PM - Male
Packard
Connector
XXVDC XXW
CCX XXX H
PAT.XXXXXXX
MADEINU.S.A.
XXVDC XXW
CCX XXX H
Voltage
Pressure
Controls
PC
PAT.XXXXXXX
MADEINU.S.A.
Part No.
XXVDC XXW
CCX XXX H
PAT.XXXXXXX
MADEINU.S.A.
39.6
(1.56)
WE - Double Screw
with 3 Amp Diode
LM
Load/Motor
Controls
XXVDC XXW
CCX XXX H
PAT.XXXXXXX
MADEINU.S.A.
XXVDC XXW
CCX XXX H
PAT.XXXXXXX
MADEINU.S.A.
XXVDC XXW
CCX XXX H
PAT.XXXXXXX
MADEINU.S.A.
33.8
(1.33)
SH
Shuttle
Valves
L - Double Lead
18 gauge 457mm 18" long
black color
S - Double Spade
Flow
Controls
19.8
(0.78)
Check
Valves
53.0
(2.07)
D - DIN 43650
XXVDC XXW
CCX XXX H
PAT.XXXXXXX
MADEINU.S.A.
(+ and - metered)
XXVDC XXW
CCX XXX H
PAT.XXXXXXX
MADEINU.S.A.
XXVDC XXW
CCX XXX H
PAT.5002253
MADEINU.S.A.
XXVDC XXW
CCX XXX H
PAT.XXXXXXX
MADEINU.S.A.
75.0
(2.97)
DC
DT04 - 2P - EP04
HE - Integral Deutsch
with 3 Amp Diode
MV
53.0
(2.07)
64.0
(2.53)
62.74
(2.47)
Directional
Controls
C - Double Lead
177.0
(7.0)
H - Integral Deutsch
Manual
Valves
57.0
(2.25)
Logic
Elements
LE
SV
Solenoid
Valves
NOTES:
1. The standard A.C. coil includes a molded-in full wave rectifier rated for 800 peak reverse voltage.
2. All P Puissant (high wattage) coils use a red ring as an indiction marker on the terminal boss.
Proportional
Valves
PV
Coils &
Electronics
CE
Bodies &
Cavities
BC
Technical
Data
TD
CE4
Features
Check
Valves
SH
Shuttle
Valves
LM
Load/Motor
Controls
FC
Flow
Controls
PC
Pressure
Controls
LE
Ordering Information
CA
Super Coil
5/8 I.D.
Specifications
Coil Type
S
P
Standard
Puissant
Nominal Wattage
(See Ordering
Information For
Exact Wattage)
S
P
18 Watts
28 Watts
Wattage
Voltage
Termination
Code Wattage
S
Standard
Puissant
Code
Voltage
Watts
Amps
Ohms**
S
P
Duty Cycle
010
10 VDC
18
28
1.80
2.80
5.56
3.57
Magnetic Wire
Insulation Class
012*
018
12 VDC
18 VDC
18
18
28
28
1.50
1.00
2.33
1.56
8.00
18.0
5.14
11.6
Temperature
Range
-40C to +200C
(-40F to +392F)
024*
24 VDC
18
28
0.75
1.17
32.0
20.6
Temperature
Rise At Nominal
Voltage And
Natural Ventilation
S
P
048
115*
48 VDC
115 VAC
18
18
28
28
0.38
0.20
230
230 VAC
18
28
0.10
0.15
Dielectric Strength
Maximum Current
Leakage (Amps)
Encapsulating
Material
PV
Proportional
Valves
Logic
Elements
Volts
Color Identification S
On The Terminal
P
Boss
CE
Weight
DC
Directional
Controls
MV
Manual
Valves
SV
75C (135F)
95C (172F)
*Standard Voltages
2100 1430
Code Termination
Solenoid
Valves
A
AD
C
*D
H
HE
HS
*L
LS
LD
Black Ring
Red Ring
LE
PF
Coils &
Electronics
AC Coil Assembly
PM
*S
*W
WE
*Y
BC
Bodies &
Cavities
TD
Technical
Data
CE5
L - Double Lead
S - Double Spade
A - Amp Junior
AD - Amp Junior
with 3 Amp Diode
(+ and - metered)
LE - Double Lead
with 3 Amp Diode
WE - Double Screw
with 3 Amp Diode
(+ and - metered)
61.0
(2.40)
C - Double Lead
Conduit (1/2" NPTF)
18 gauge 457mm 18" long, black color
Load/Motor
Controls
PM - Male
Packard
Connector
PF - Female
Packard
Connector
Logic
Elements
DC
57.0
(2.23)
178.0
(7.0)
H - Integral Deutsch
DT04 - 2P - EP04
HE - Integral Deutsch
with 3 Amp Diode
PC
LE
XXVDC XXW
CAX XXX H
PAT.XXXXXXX
MADEINU.S.A.
XXVDC XXW
CAX XXX H
PAT.XXXXXXX
MADEINU.S.A.
Voltage
FC
Directional
Controls
XXVDC XXW
CAX XXX H
PAT.XXXXXXX
MADEINU.S.A.
W - Double Screw
71.0
(2.79)
Flow
Controls
Y - Single Screw
LM
Pressure
Controls
57.0
(2.23)
XXVDC XXW
CAX XXX H
PAT.XXXXXXX
MADEINU.S.A.
60.0
(2.36)
(Internal ground)
8-32 UNC screw & nut
Part No.
XXVDC XXW
CAX XXX H
PAT.XXXXXXX
MADEINU.S.A.
XXVDC XXW
CAX XXX H
43.0
(1.71)
PAT.XXXXXXX
MADEINU.S.A.
16 (.64) I.D.
50.0
(1.97)
SH
Shuttle
Valves
36.0
(1.43)
Check
Valves
D - DIN 43650
MV
PAT.XXXXXXX
MADEINU.S.A.
57.0
(2.23)
68.0
(2.68)
Solenoid
Valves
SV
PV
NOTES:
1. The standard A.C. coil includes a molded-in full wave rectifier rated for 800 peak reverse voltage.
2. All P Puissant (high wattage) coils use a red ring as an indiction marker on the terminal boss. (No ring on Integral Deutsch connector.)
Proportional
Valves
66.5
(2.62)
XXVDC XXW
CAX XXX H
PAT.XXXXXXX
MADEINU.S.A.
XXVDC XXW
CAX XXX H
PAT.XXXXXXX
MADEINU.S.A.
XXVDC XXW
CAX XXX H
PAT.XXXXXXX
MADEINU.S.A.
79.0
(3.12)
Manual
Valves
(+ and - metered)
Coils &
Electronics
CE
Bodies &
Cavities
BC
Technical
Data
TD
CE6
Features
Check
Valves
SH
Shuttle
Valves
LM
Load/Motor
Controls
FC
Flow
Controls
PC
Pressure
Controls
LE
Logic
Elements
Directional
Controls
Manual
Valves
SV
Optional
(With Diode Consult Factory)
Ordering Information
Specifications
Wattage
Duty Rating
Wire Class
Heat Rise
A.C. Rectifier
Lead Wire
Lead Wire
Strain Relief
Encapsulating
Material
DC
MV
Standard
(Without Diode)
Finish
14 Watts
Continuous @ 100% voltage
Class N - 200C (392F)
45C (115F) over ambient
Integral full wave bridge
18 gauge 24 long, 600 volt rating
34 kg (75 lbs.) @ 21C (70F) &
18 kg (40 lbs.) @ 93C (200F)
Rynite, resistant to moisture,
caustic solutions, fungus,
and temperatures from
-40C (-40F) to 200C (392F)
Coil - Black
Frame - Yellow zinc dichromate
Type
PG9
PG11
1.57
Non-Rectified
710549-00
710549-01
Rectified
712126-01
712126-00
.39
1.04
Solenoid
Valves
Proportional
Valves
1.04
Conduit
Coils &
Electronics
2.45
Termination
Diode
Voltage
Code Termination
C
*Conduit With Leads
Diode
J
M
Amp Jr.
Metri-Pack
*Dual Spade
S
W
*Dual Screw
Dual Lead (DC Only)
WS
1.04
Rectified
712704-00
Wattage
.06
Conduit
Unicoil
1/2 I.D.
Code Diode
Omit Without Diode
PV
CE
Code Wattage
L 14 Watt
S8
Code
Voltage
Current
Amps
2.40
Resistance
Ohms
2.5
Lead
Color
Black
*D006
6 VDC
*D010
D012
*D018
10 VDC
1.45
6.9
Yellow
12 VDC
18 VDC
1.17
0.84
10.2
21.5
Red
Gray
D024
24 VDC
0.57
41.8
Blue
*D036
*D048
36 VDC
48 VDC
0.45
0.32
80.5
150.6
Orange
Green
A120
120 VAC
0.16
663
Brown
A240
240 VAC
* Consult Factory.
0.07
3032
White
Non-Rectified
710549-02
1.57
BC
1.04
1.37
.06
Bodies &
Cavities
.06
1.06
.22
.22
1.04
TD
Technical
Data
1.06
1.00
1.04
CE7
Nut Side
Double Lead
1/2" NPTF
1.752 1.602
0.080
1.18
1.312
Nut Side
1.49
0.080
Cartridge Side
1.312
ISO Standard
DIN 43650
Plug Face Only
1.752 1.602
Type C - Male
Connector
Nut Side
1.752 1.602
1.47
1.20
0.080
Cartridge Side
0.564
Cartridge Side
Type J
Amp Jr.
Type D
DIN Plug Face 43650
Type C
Conduit
SH
Shuttle
Valves
1.18
1.312
1.671
0.896
0.881
0.42
LM
Load/Motor
Controls
0.875
1.671
0.881
1.155
FC
Flow
Controls
1.671
0.881
1.316
1.312
Nut Side
1.752 1.602
Nut Side
1.120
0.080
Cartridge Side
Nut Side
8-32 Screw
and Nut
1.752 1.602
1.506
1.20
0.080
Cartridge Side
LE
0.995
1.584
Cartridge Side
Type P
Dual Spade
Type S
Double Screw
DC
MV
Manual
Valves
Type M
Metri-Pack 150.2 Series
Mating Connector 12162193
0.545
1.312
Thru Holes
Tinned Brass
SAE 1B-0.25
1.752 1.602
1.20
0.080
1.671
0.881
0.860 1.180
1.312
Packard
#12162269
0.50
Logic
Elements
1.671
0.881
1.233
Directional
Controls
1.671
0.881
Pressure
Controls
PC
Nut Side
Solenoid
Valves
PV
18 Gauge
Nut Side 24" Long
1.752 1.602
0.080
Cartridge Side
Type W
Dual Lead
1.335
Code Connector
WS
24" Leads
WS6 6" Leads
Cartridge Side
Type WS
Weather Pack Shroud 12010973
Mating Connector 12015792
CE
Bodies &
Cavities
BC
TD
Technical
Data
0.080
1.355
0.660
1.312
18 Gauge
24" Long
1.752 1.602
SV
0.390
Proportional
Valves
0.660
1.312
1.671
0.881
Coils &
Electronics
0.390
1.671
0.881
CE8
Features
Check
Valves
SH
Shuttle
Valves
LM
Load/Motor
Controls
FC
Flow
Controls
PC
Pressure
Controls
LE
Logic
Elements
Directional
Controls
Manual
Valves
SV
Optional
(With Diode Consult Factory)
Ordering Information
Specifications
Wattage
Duty Rating
Wire Class
Heat Rise
A.C. Rectifier
Lead Wire
Lead Wire
Strain Relief
Encapsulating
Material
DC
MV
Standard
(Without Diode)
Finish
20 Watts
Continuous @ 100% voltage
Class N - 200C (392F)
45C (115F) over ambient
Integral full wave bridge
18 gauge 24 long, 600 volt rating
34 kg (75 lbs.) @ 21C (70F) &
18 kg (40 lbs.) @ 93C (200F)
Rynite, resistant to moisture,
caustic solutions, fungus,
and temperatures from
-40C (-40F) to 200C (392F)
Coil - Black
Frame - Yellow zinc dichromate
1.57
Type
PG9
PG11
Non-Rectified
710549-00
710549-01
Rectified
712126-01
712126-00
.39
1.04
Solenoid
Valves
Proportional
Valves
1.04
Diode
Voltage
Code Termination
C
*Conduit With Leads
Diode
J
M
Amp Jr.
Metri-Pack
*Dual Spade
S
W
*Dual Screw
Dual Lead (DC Only)
WS
Code
Voltage
Current
Amps
3.33
Resistance
Ohms
1.8
Lead
Color
Black
*D006
6 VDC
*D010
D012
*D018
10 VDC
2.10
4.8
Yellow
12 VDC
18 VDC
1.67
1.21
7.2
14.9
Red
Gray
D024
24 VDC
0.88
27.4
Blue
*D036
*D048
36 VDC
48 VDC
0.61
0.47
58.9
102.4
Orange
Green
A120
120 VAC
0.192
626
Brown
A240
240 VAC
0.10
2400
White
* Consult Factory.
Conduit
Coils &
Electronics
2.45
Termination
1.04
Rectified
712704-00
Wattage
.06
Conduit
Unicoil
5/8 I.D.
Code Diode
Omit Without Diode
PV
CE
Code Wattage
L 20 Watt
S10
Non-Rectified
710549-02
1.57
BC
1.04
1.37
.06
Bodies &
Cavities
.06
1.06
.22
.22
1.04
TD
Technical
Data
1.06
1.00
1.04
CE9
1.927
1.927
1.025
1.025
1.145
Double Lead
1/2" NPTF
2.124 1.964
1.180
Nut Side
1.470
ISO Standard
DIN 43650
Plug Face Only
Nut Side
2.124 1.964
1.485
0.080
Cartridge Side
1.215
0.080
Cartridge Side
0.579
Cartridge Side
Type J
Amp Jr.
Type D
DIN Plug Face 43650
Type C
Conduit
LM
Type C
Male
2.124 1.964
1.505
0.080
Shuttle
Valves
1.470
FC
Flow
Controls
Nut Side
0.886
0.865
1.180
1.470
SH
1.025
Load/Motor
Controls
1.927
1.927
1.927
1.927
1.025
1.025
Pressure
Controls
PC
1.025
1.231
0.490
0.535
LE
Nut Side
1.470
0.860 1.180
Nut Side
1216229
Nut Side
1.135
0.080
1.521
1.215
0.080
Cartridge Side
1.599
Cartridge Side
Type S
Double Screw
Type P
Dual Spade
DC
MV
Manual
Valves
Type M
Metri-Pack 150.2 Series
Mating Connector 12162193
8-32 Screw
and Nut
2.124 1.964
1.215
Cartridge Side
0.995
Thru Holes
Tinned Brass
SAE 18-0.25
2.124 1.964
2.124 1.964
0.080
1.470
Logic
Elements
1.385
Directional
Controls
1.470
SV
1.927
0.380
0.652
1.470
Nut Side
0.380
1.470
0.652
18 Gauge
24" Long
Nut Side
1.370
Cartridge Side
1.370
0.080
Type W
Dual Lead
Code Connector
WS
24" Leads
WS6 6" Leads
Cartridge Side
Type WS
Weather Pack Shroud 12010973
Mating Connector 12015792
CE
Bodies &
Cavities
BC
TD
Technical
Data
0.080
PV
18 Gauge
24" Long
2.124 1.964
2.124 1.964
Solenoid
Valves
1.025
Proportional
Valves
1.025
Coils &
Electronics
1.927
CE10
Features
Check
Valves
SH
Shuttle
Valves
LM
Load/Motor
Controls
FC
Flow
Controls
PC
Pressure
Controls
LE
Specifications
Logic
Elements
Wattage
Duty Rating
Wire Class
A.C. Rectifier
Lead Wire
Lead Wire
Strain Relief
Encapsulating
Material
Symbol
DC
Directional
Controls
MV
Manual
Valves
SV
PV
Proportional
Valves
Solenoid
Valves
AC Coil Assembly
AC Coil Assembly
CE
Coils &
Electronics
NOTE:
Parker A.C. Coils incorporate integrally molded full
wave rectifiers which are rated for reverse voltage
peaks of 1000 volts maximum. For voltage transients
greater than 1000 volts P.I.V., Harris Thyrector
V150LA10A or V150LA20A for 115 VAC and
V250LA15A or V250LA40A for 200 VAC is
recommended.
BC
Bodies &
Cavities
Voltage Surge
Suppressor (Thyrector)
TD
Technical
Data
CE11
Type W
Dual Lead
Type P
Dual Spade
Thru Hole
Tinned Brass
SAE 1B-0.25
18 Gauge
24" Long
Voltage
Part No.
25.8
(1.02)
Type D
DIN
Type S
Double Screw
DIN 43650
Plug Face Only
LM
40.4
(1.59)
Load/Motor
Controls
33.5
(1.32)
37.1
(1.46)
Type J
AMP Junior
Timer Type C
8-32 Screw
& Nut
FC
Flow
Controls
33.7
(1.33)
SH
24" Long
Shuttle
Valves
28.6
(1.13)
Type C
Double Lead With
Conduit Connector
Check
Valves
33.1
(1.31)
PC
40.8
(1.61)
Pressure
Controls
36.6
(1.44)
NOTES:
1. Coil to be installed with part number on nut side.
2. For additional terminals, voltages and wattages,
consult factory for details.
Logic
Elements
LE
851009-006
851003-006*
851005-006*
851011-006
2.22
25
851008-006
851010-006
851004-006
851006-006
851012-006
3.90
**48 VDC
120 VAC
230 VAC
**440 VAC
**Consult Factory
Lead Wire
Color
Black
12
851007-010
851009-010
851003-010*
851005-010*
851011-010
1.43
25
851008-010
851010-010
851004-010
851006-010
851012-010
2.48
12
851007-012
851009-012
851003-012*
851005-012*
851011-012
1.05
25
851008-012
851010-012
851004-012
851006-012
851012-012
1.94
12
851007-018
851009-018
851003-018*
851005-018*
851011-018
0.75
25
851008-018
851010-018
851004-018
851006-018
851012-018
1.42
12
851007-024
851009-024
851003-024*
851005-024*
851011-024
0.52
25
851008-024
851010-024
851004-024
851006-024
851012-024
1.17
12
851007-036
851009-036
851003-036*
851005-036*
851011-036
0.38
25
851008-036
851010-036
851004-036
851006-036
851012-036
0.73
12
851007-048
851009-048
851003-048*
851005-048*
851011-048
0.26
25
851008-048
851010-048
851004-048
851006-048
851012-048
0.59
12
851003-120
851005-120
0.14
25
851004-120
851006-120
0.23
12
851003-240
851005-240
0.08
25
851004-240
851006-240
0.12
12
851003-480
851005-480
0.04
25
851004-480
851006-480
0.07
*UL Listed
Yellow
Red
Gray
Blue
Orange
Green
Brown
White
Violet
MV
SV
PV
CE
BC
TD
Technical
Data
**36 VDC
Amps
Manual
Valves
851007-006
24 VDC
Type S
Double
Screw
Solenoid
Valves
12
**18 VDC
Type D
DIN
Plug Face
Proportional
Valves
**6 VDC
12 VDC
Type C
Conduit
Connector
Coils &
Electronics
Watts
**10 VDC
Type W
Double
Lead
Bodies &
Cavities
Voltage
Type P
Double
Spade
Directional
Controls
DC
CE12
Features
Check
Valves
SH
Shuttle
Valves
LM
Load/Motor
Controls
FC
Flow
Controls
Specifications
Wattage
Duty Rating
Wire Class
A.C. Rectifier
Lead Wire
Lead Wire
Strain Relief
Encapsulating
Material
PC
Pressure
Controls
LE
Logic
Elements
DC
Directional
Controls
MV
Manual
Valves
SV
Symbol
AC Coil Assembly
Solenoid
Valves
PV
Proportional
Valves
AC Coil Assembly
CE
NOTE:
Parker A.C. Coils incorporate integrally molded full
wave rectifiers which are rated for reverse voltage
peaks of 1000 volts maximum. For voltage transients
greater than 1000 volts P.I.V., Harris Thyrector
V150LA10A or V150LA20A for 115 VAC and
V250LA15A or V250LA40A for 200 VAC is
recommended.
Coils &
Electronics
BC
Bodies &
Cavities
Voltage Surge
Suppressor (Thyrector)
TD
Technical
Data
CE13
Type W
Dual Lead
Type P
Dual Spade
Thru Hole
Tinned Brass
SAE 1B-0.25
18 Gauge
24" Long
Voltage
Part No.
38.4
(1.51)
28.6
(1.13)
Type D
DIN
LM
42.2
(1.66)
Load/Motor
Controls
40.6
(1.60)
Type J
AMP Junior
Timer Type C
DIN 43650
Plug Face Only
FC
Flow
Controls
45.0
(1.77)
SH
24" Long
Shuttle
Valves
31.7
(1.25)
Type C
Double Lead With
Conduit Connector
Check
Valves
PC
40.8
(1.61)
Pressure
Controls
40.2
(1.58)
NOTES:
1. Coil to be installed with part number on nut side.
2. For additional terminals, voltages and wattages,
consult factory for details.
Logic
Elements
LE
851023-006
851017-006
851019-006
2.43
30
851022-006
851024-006
851018-006
851020-006
4.84
48 VDC
120 VAC
230 VAC
440 VAC
Black
17
851021-010
851023-010
851017-010
851019-010
1.58
30
851022-010
851024-010
851018-010
851020-010
3.28
17
851021-012
851023-012
851017-012
851019-012
1.44
30
851022-012
851024-012
851018-012
851020-012
2.30
17
851021-018
851023-018
851017-018
851019-018
0.94
30
851022-018
851024-018
851018-018
851020-018
1.86
17
851021-024
851023-024
851017-024
851019-024
0.72
30
851022-024
851024-024
851018-024
851020-024
1.20
17
851021-036
851023-036
851017-036
851019-036
0.43
30
851022-036
851024-036
851018-036
851020-036
0.88
17
851021-048
851023-048
851017-048
851019-048
0.30
30
851022-048
851024-048
851018-048
851020-048
0.58
17
851017-120
851019-120
0.15
30
851018-120
851020-120
0.24
17
851017-240
851019-240
0.08
30
851018-240
851020-240
0.13
17
851017-480
851019-480
0.04
30
851018-480
851020-480
0.07
Yellow
Red
Gray
Blue
Orange
Green
Brown
White
Violet
MV
SV
PV
CE
BC
TD
Technical
Data
36 VDC
Lead Wire
Color
Manual
Valves
851021-006
24 VDC
Amps*
Solenoid
Valves
17
18 VDC
Type D
DIN
Plug Face
Proportional
Valves
6 VDC
12 VDC
Type C
Conduit
Connector
Coils &
Electronics
Watts
10 VDC
Type W
Double
Lead
Bodies &
Cavities
Voltage
Type P
Double
Spade
Directional
Controls
DC
CE14
Features
Shuttle
Valves
LM
Specifications
Check
Valves
SH
Load/Motor
Controls
FC
Flow
Controls
PC
Pressure
Controls
LE
Wattage
42 Watts Standard
30 Watts Low Watt
Duty Rating
Wire Class
Lead Wire
Lead Wire
Strain Relief
Encapsulating
Material
Color
Black
AC Coil Assembly
No inductive or capacitive loads can be installed
between surge suppressor and rectified valves.
AC Coil Assembly
Logic
Elements
Voltage Surge
Suppressor (Thyrector)
DC
Directional
Controls
Type W
Double Lead
Type P
Dual Spade
Thru Hole
Tinned Brass
SAE 1B-0.25
48.1
(1.89)
18 Gauge
24" Long
MV
Voltage
Manual
Valves
Part No.
56.0
(2.20)
SV
40.7
(1.60)
40.7
(1.60)
Solenoid
Valves
59.8
(2.35)
Type D
ISO Standard
Type C
Double Lead With
Conduit Connector
PV
DIN 43650
Plug Face Only
Proportional
Valves
NOTES:
CE
Coils &
Electronics
BC
Bodies &
Cavities
TD
50.6
(1.99)
51.8
(2.04)
Voltage
Type P
Double Spade
Type W
Double Lead
Type D
ISO STANDARD
Amps
Lead Wire
Color
42 Watts
42 Watts
12 VDC
24 VDC
851060-012*
851060-024*
851062-012*
851062-024*
851058-012*
851058-024*
3.53
1.79
Red
Blue
Technical
Data
30 Watts
12 VDC
853496-012
853497-012
853495-012
2.50
Red
30 Watts
24 VDC
853496-024
853497-024
853495-024
1.25
Blue
*UL Listed
CE15
Check
Valves
CV
Shuttle
Valves
SH
Load/Motor
Controls
LM
Flow
Controls
FC
Pressure
Controls
PC
Logic
Elements
LE
Directional
Controls
DC
Manual
Valves
MV
Solenoid
Valves
SV
Proportional
Valves
PV
Coils &
Electronics
CE
Bodies &
Cavities
BC
Technical
Data
TD
CE16
General Description
Check
Valves
SH
Shuttle
Valves
LM
Load/Motor
Controls
FC
Flow
Controls
PC
Pressure
Controls
LE
Logic
Elements
DC
I Max Adjustment
0 - 100 %
Operation
The 902/932 and 904/934 are valve top mounted PWM
controllers for proportional control valves. They can be
used with an external potentiometer to give accurate
current control using the units internal reference
voltage. Alternatively these controllers can be used
with a 0-10V command signal from a PLC or engine
management system.
Output LED
Directional
Controls
Features
Nominal
Voltage
Solenoid
Valves
Maximum
Power
Proportional
Valves
Coils &
Electronics
12V DC
12V DC
24V DC
24V DC
XPRO902
XPRO932
XPRO904
XPRO934
19W
30W
19W
30W
IP 65
Maximum
Current
XPRO902
XPRO932
XPRO904
XPRO934
1.6A
2.6A
1.0A
1.4A
0.7
0.6
0.5
0.4
0.3
XPRO
Non-XPRO
0.2
Command Voltage
0 - 10V
Input Resistance
10K ohms
Refference Voltage
XPRO902
XPRO932
XPRO904
XPRO934
Cable Length
1 meter
Application
Frequency
110 Hz 5%
For use with most proportional valves. GP, HP, JP, GTP
and AP series valves.
0.1
Bodies &
Cavities
TD
XPRO902
XPRO932
XPRO904
XPRO934
(IP) Rating
CE
BC
Current, A
Manual
Valves
PV
Output Regulation
Specifications
MV
SV
0
0.5
+8V (2mA)
+8V (2mA)
+15V (2mA)
+15V (2mA)
Technical
Data
CE17
2.5
4.5
6.5
8.5
10.5 12.5
Time, minutes
14.5
16.5
18.5
Ordering Information
Millimeters (Inches)
34.0
(1.34)
68.0
(2.68)
Check
Valves
Dimensions
XPRO
SH
40.0
(1.57)
Maximum
Current
Shuttle
Valves
Controller
LM
Load/Motor
Controls
932 2.6A
904 1.0A
934 1.4A
Flow
Controls
FC
Connection Details
10K Potentiometer
Red: +12V
Red: +24V
Green: Command
Green: Command
LE
Logic
Elements
10K Potentiometer
Pressure
Controls
PC
XPRO902 and XPRO932
Blue: 0V
Blue: 0V
Blue: 0V Supply
Blue: 0V Supply
Directional
Controls
DC
From PLC
Red: +12V
Red: +24V
Manual
Valves
MV
From PLC
SV
0-10V
Green: Command
Green: Command
Solenoid
Valves
0-10V
0V
0V
Blue: 0V
Blue: 0V
Blue: 0V Supply
Blue: 0V Supply
Proportional
Valves
PV
Controller
XPRO 904
XPRO 934
X
X
X
X
BC
Bodies &
Cavities
Controller
XPRO 902
XPRO 932
X
X
X
X
TD
Technical
Data
Coil
CCS012D
CCP012D
CAS012D
CAP012D
Coils &
Electronics
CE
CE18
General Description
Shuttle
Valves
LM
Load/Motor
Controls
FC
Flow
Controls
PC
Pressure
Controls
LE
Logic
Elements
DC
Directional
Controls
MV
Manual
Valves
SV
Solenoid
Valves
PV
Proportional
Valves
CE
Coils &
Electronics
BC
I Max Adjustment
0 - 100%
Operation
The 902d/932d and 904d/934d are valve top mounted
PWM controllers for proportional control valves. They
can be used with an external potentiometer to give
accurate current control using the units internal
reference voltage. Alternatively these controllers can
be used with a 0-10V command signal from a PLC or
engine management system.
Frequency
Output LED
Output Regulation
(Curve shows coil temperature compensation)
0.7
0.6
Specifications
Nominal
Voltage
XPRO902d
XPRO932d
XPRO904d
XPRO934d
12V DC
12V DC
24V DC
24V DC
Maximum
Power
XPRO902d
XPRO932d
XPRO904d
XPRO934d
19W
30W
19W
30W
(IP) Rating
IP 65
Maximum
Current
XPRO902d
XPRO932d
XPRO904d
XPRO934d
Bodies &
Cavities
Command Voltage
0 - 10V
Input Resistance
10K ohms
Refference Voltage
XPRO902d
XPRO932d
XPRO904d
XPRO934d
Cable Length
1 meter
Frequency
95 Hz - 230 Hz
TD
Features
0.5
Current, A
Check
Valves
SH
0.4
0.3
Non-XPRO
0.2
1.6A
2.6A
1.0A
1.4A
0.1
0
0.5
+8V (2mA)
+8V (2mA)
+15V (2mA)
+15V (2mA)
XPRO
2.5
4.5
6.5
8.5
10.5 12.5
Time, minutes
14.5
16.5
18.5
Application
Technical
Data
For use with most proportional valves. GP, HP, JP, GTP
and AP series valves.
CE19
Ordering Information
Millimeters (Inches)
34.0
(1.34)
68.0
(2.68)
Check
Valves
Dimensions
XPRO
SH
40.0
(1.57)
Maximum
Current
Shuttle
Valves
Controller
LM
Load/Motor
Controls
932d 2.6A
904d 1.0A
934d 1.4A
Setting for standard:
Dither frequency: 110 HZ
Flow
Controls
FC
Connection Details
10K Potentiometer
Red: +12V
Red: +24V
Green: Command
Green: Command
LE
Logic
Elements
10K Potentiometer
Pressure
Controls
PC
XPRO902d and XPRO932d
Blue: 0V
Blue: 0V
Blue: 0V Supply
Blue: 0V Supply
Directional
Controls
DC
From PLC
Red: +12V
Red: +24V
Manual
Valves
MV
From PLC
SV
0-10V
Green: Command
Green: Command
Solenoid
Valves
0-10V
0V
0V
Blue: 0V
Blue: 0V
Blue: 0V Supply
Blue: 0V Supply
Proportional
Valves
PV
Controller
XPRO 904d
XPRO 934d
X
X
X
X
BC
Bodies &
Cavities
Controller
XPRO 902d
XPRO 932d
X
X
X
X
TD
Technical
Data
Coil
CCS012D
CCP012D
CAS012D
CAP012D
Coils &
Electronics
CE
CE20
General Description
Check
Valves
I Max Adjustment
0 - 100%
Output LED
SH
Operation
Load/Motor
Controls
FC
Flow
Controls
PC
Pressure
Controls
LE
Logic
Elements
DC
Directional
Controls
MV
Manual
Valves
SV
Solenoid
Valves
PV
Proportional
Valves
CE
Specifications
Coils &
Electronics
Nominal
Voltage
Maximum
Power
(IP) Rating
IP 65
Maximum
Current
XPRO902rid
XPRO932rid
XPRO904rid
XPRO934rid
Command Voltage
0 - 10V
BC
Bodies &
Cavities
10K ohms
Refference Voltage
Cable Length
1 meter
Ramp Up/Down
200ms - 8s
Frequency
Ramp Up
I min 0 - 50%
Features
Output Regulation
(Curve shows coil temperature compensation)
0.7
0.6
0.5
0.4
0.3
XPRO
Non-XPRO
0.2
1.6A
2.6A
1.0A
1.4A
Input Resistance
TD
Ramp Down
Current, A
Shuttle
Valves
LM
0.1
0
0.5
2.5
4.5
6.5
8.5
10.5 12.5
Time, minutes
14.5
16.5
18.5
Application
Technical
Data
For use with most proportional valves. GP, HP, JP, GTP
and AP series valves.
CE21
Ordering Information
Millimeters (Inches)
34.0
(1.34)
68.0
(2.68)
Check
Valves
Dimensions
XPRO
SH
40.0
(1.57)
Maximum
Current
Shuttle
Valves
Controller
LM
Load/Motor
Controls
932rid 2.6A
904rid 1.0A
934rid 1.4A
Setting for standard:
Dither frequency: 110 HZ
Flow
Controls
FC
Connection Details
10K Potentiometer
Red: +12V
Red: +24V
Green: Command
Green: Command
LE
Logic
Elements
10K Potentiometer
Pressure
Controls
PC
XPRO902rid and XPRO932rid
Blue: 0V
Blue: 0V
Blue: 0V Supply
Blue: 0V Supply
Directional
Controls
DC
From PLC
Red: +12V
Red: +24V
Manual
Valves
MV
From PLC
SV
0-10V
Green: Command
Green: Command
Solenoid
Valves
0-10V
0V
0V
Blue: 0V
Blue: 0V
Blue: 0V Supply
Blue: 0V Supply
Proportional
Valves
PV
Controller
XPRO 904rid
XPRO 934rid
X
X
X
X
BC
Bodies &
Cavities
Controller
XPRO 902rid
XPRO 932rid
X
X
X
X
TD
Technical
Data
Coil
CCS012D
CCP012D
CAS012D
CAP012D
Coils &
Electronics
CE
CE22
General Description
Shuttle
Valves
LM
Load/Motor
Controls
FC
Flow
Controls
PC
Pressure
Controls
LE
Logic
Elements
DC
Features
XPRO
704
Operation
The 704 is a soft start plug top PWM controller used
for reducing the hydraulic pressure peaks produced
when a hydraulic valve is operated. It can simply be
used in place of a standard DIN connector.
Output Voltage
12/24V
Dimensions
Millimeters (Inches)
48.0
(1.90)
Directional
Controls
Voltage To Coil
Check
Valves
SH
XPRO
704
28.0
(1.10)
MV
Manual
Valves
SV
Solenoid
Valves
PV
Proportional
Valves
CE
Coils &
Electronics
BC
0.5
1.0
1.5
2.0
Time sec
Connection Details
Application
For use with most proportional valves. GP, HP, JP, GTP
and AP series valves.
Specifications
XPRO
704
Blue 0V Supply
Nominal Voltage
Maximum Power
36W
(IP) Rating
IP 65
Maximum Current
3.0A
Coil Resistance
4.5 - 30 ohms
Ramp Up
Fixed 1000ms
Ordering Information
Bodies &
Cavities
XPRO
704
TD
Controller
Plug Type
Technical
Data
CE23
Step point up
SH
Shuttle
Valves
Features
Check
Valves
General Description
Operation
The 704b is a valve top mounted soft start, soft stop
controller for use with a range of valves.
The controller can be set to jump to a preset step
voltage then ramp up to maximum at a preset rate. It
can also be set to jump down to a preset step voltage
and ramp down to zero. This can be used to eliminate
bangs or hydraulic shocks associated with operating a
hydraulic valve.
Flow
Controls
FC
34.0
(1.34)
Step Up
Set Point
Step Down
Set Point
MV
Manual
Valves
Ramp Rate
Down
Control
Signal Off
DC
Directional
Controls
Ramp
Rate Up
LE
Logic
Elements
68.0
(2.68)
Time
Application
For use with most proportional valves. GP, HP, JP, GTP
and AP series valves.
Connection Details
Connect to
Switch
SV
Specifications
Solenoid
Valves
Voltage To Coil
Millimeters (Inches)
34.0
(1.34)
Control Signal On
Pressure
Controls
PC
Dimensions
Output Voltage
Load/Motor
Controls
LM
Maximum Power
36W
(IP) Rating
IP 65
Maximum Current
3.0A
Coil Resistance
4.8 - 30 ohms
Coil Voltage
+V Supply
Coils &
Electronics
PV
Nominal Voltage
Ordering Information
BC
1 meter
Step Up Adjust
10 - 80%
10 - 80%
Ramp Up/Down
200ms - 4s
Proportional
Valves
XPRO
704b
Controller
Plug Type
TD
CE24
CE
Bodies &
Cavities
Cable Length
Blue: 0V Supply
Technical
Data
Green/Yellow: Control
General Description
Check
Valves
SH
Shuttle
Valves
LM
Load/Motor
Controls
FC
Flow
Controls
PC
Pressure
Controls
LE
Features
XPRO
804
Operation
The 804 is a power saver plug top PWM controller
used for reducing the current consumption of a standard on/off valve. The plug will deliver full voltage to
the valve for 50mS then drop down to a holding
voltage of 30% of the applied voltage. This can be
used where multiple valves are used and power
consumption is a consideration. It can simply be used
in place of a standard DIN connector.
Dimensions
Millimeters (Inches)
Logic
Elements
DC
Voltage, V
Directional
Controls
MV
XPRO
804
Manual
Valves
SV
50
100
150
200
250
Solenoid
Valves
PV
Proportional
Valves
Coils &
Electronics
BC
Connection Details
Time minutes
Application
CE
28.0
(1.10)
XPRO
804
Blue 0V Supply
Specifications
Bodies &
Cavities
Nominal Voltage
Maximum Power
36W
(IP) Rating
IP 65
Maximum Current
3.0A
Coil Resistance
4.5 - 30 ohms
Current Reduction
30% of Max
Ordering Information
TD
XPRO
804
Controller
Plug Type
Technical
Data
CE25
Check
Valves
CV
Shuttle
Valves
SH
Load/Motor
Controls
LM
Flow
Controls
FC
Pressure
Controls
PC
Logic
Elements
LE
Directional
Controls
DC
Manual
Valves
MV
Solenoid
Valves
SV
Proportional
Valves
PV
Coils &
Electronics
CE
Bodies &
Cavities
BC
Technical
Data
TD
CE26