ISSN 1818-4952
IDOSI Publications, 2014
DOI: 10.5829/idosi.wasj.2014.29.04.13861
Pass ability
Recycle concrete
INTRODUCTION
Self compacting
Sump flow
Corresponding Author: Sherif A. Khafaga, Housing and Building National Research Center, Dokki, Giza, Egypt.
465
Measured values
Fineness (cm2/gm)
3500
--
Specific Gravity
3.15
--
Expansion (mm)
1.1
1.9167
3.334
--
2 days
18.6
28 days
50.8
Specific weight
Dolomite
10
2.80
1.59
19.3
Coefficient of abrasion %
14.5
Coarse RCA
10
2.60
1.52
2.7
24.6
26.8
Specification Limit *
2.50
30
30
* Egyptian Code for design and construction for concrete structures 203/2007 [12].
Table 3: Properties of fine aggregate.
Specimen
Specific weight
Natural sand
2.70
1.53
Absorption %
1.10
Fine RCA
2.60
1.43
3.00
Specification Limit *
2.00
*Egyptian Code for design and construction for concrete structures 203/2007 [12]
Mix No.
% Coarse RCA
% Fine RCA
V funnel test
--------------------------t0 (sec)
t5min (sec)
720
6.2
8.2
10
2
3
4
5
25
0
25
50
75
685
660
650
645
4.5
4.7
4.6
5
6.6
7.2
8.2
8.8
9.3
10
10.5
10.6
12
13
15
16
6
7
8
9
50
0
25
50
75
650
645
625
610
4.6
4.8
4.85
5
6.9
7.3
7.4
8.9
9.5
10.1
10.1
11.2
13
15
17
18
10
11
12
13
75
0
25
50
75
645
640
615
605
4.3
5
4.9
5
9
9.7
10.9
12.1
12.8
13.1
13.5
14.7
17
18
19
22
740
720
720
700
685
680
660
650
645
640
620
600
0
25
50
75
100
Fig. 1: Effect of coarse RCA replacement percentage on the Slump flow of concrete
740
720
700
685
680
660
660
640
650
645
620
600
0
25
50
75
% Replacement of Sand by Fine RCA
100
Fig. 2: Effect of fine RCA on the slump flow of concrete with 25% replacement of coarse RCA
water content in the SCC mix due to the high water
absorption of RCA. The slump flow time T50 results of the
concretes with different RCA percentages are given in
Table 4. The T50 varied in the range of 4.55 seconds.
The slump flow time T50 of SCC generally ranges from 2 to
5 seconds, the obtained values of T50 were within the
acceptable range.
650
645
640
625
620
610
600
0
25
50
75
100
Fig. 3: Effect of fine RCA on the slump flow of concrete with 50% replacement of coarse RCA
740
720
700
680
660
645
640
640
620
615
605
600
0
25
50
75
% Replacement of Sand by Fine RCA
100
Fig. 4: Effect of fine RCA on the slump flow of concrete with 75% replacement of coarse RCA
Table 5: Hardened concrete test results of the studied mixtures
Mix No.
% Coarse RCA
% Fine RCA
Density (g/mm3)
28 days Tensile
strength (N/mm2)
28 days Flexural
strength (N/mm2)
63
87
72
2.43
4.89
10.20
2
3
4
5
25
0
25
50
75
56
53
53
52
80
75
74
72
70
71
71
72
2.37
2.45
2.44
2.38
3.60
3.31
3.11
3.09
10.08
10.02
9.96
9.93
6
7
8
9
50
0
25
50
75
55
51
51
49
78
72
72
69
70
71
71
70
2.38
2.29
2.39
2.34
3.36
3.23
3.17
2.93
10.08
9.79
8.86
7.80
10
11
12
13
75
0
25
50
75
52
51
49
45
71
71
69
63
72
72
72
72
2.36
2.32
2.42
2.26
3.10
3.07
2.92
2.83
8.40
7.80
7.47
7.03
17
13
12
10
25
50
% Replasement of Dolomite by Coarse RCA
75
15
12
16
13
25
50
% Replasement of Sand by Fine RCA
75
Fig. 6: Effect of Fine RCA on passing ability of SCC with 25% replacement of Coarse RCA
24
22
20
18
16
14
12
10
8
6
4
2
0
17
18
15
13
25
50
% Replasement of Sand by Fine RCA
75
Fig. 7: Effect of Fine RCA on passing ability of SCC with 50% replacement of Coarse RCA.
passing ability of concrete. The maximum differences
between the concrete height inside and outside the J-ring
( h) shall be not more than 20mm according to ETSSCC
[15], to ensure good passing ability without significant
blockage. As shown in Table 4, all SCC mixes produced in
the present study possessed reasonably good passing
ability except mix No.13. Fig. 5 indicated that the increase
in the percentage of coarse RCA used as replacement of
22
17
19
18
25
50
% Replasement of Sand by Fine RCA
75
Fig. 8: Effect of Fine RCA on passing ability of SCC with 75% replacement of Coarse RCA
100
90
87
80
80
78
71
70
60
50
40
30
20
10
0
0
25
50
% Replasement of Dolomite by Coarse RCA
75
80
75
74
72
25
50
75
70
60
50
40
30
20
10
0
0
Fig. 10: Effect of fine RCA on 28 days compressive strength of SCC with 25% replacement of coarse RCA.
Hardened Self Compacting Concrete Properties: Effect
of RCA Replacement Percentage on Concrete Density:
Table 5 shows the average densities of all mixes after
28 days. Analyzing the results appearing generally that
the density of hardened concrete slightly decreased as
the rate of natural coarse aggregates replacement by RCA
increased. This was expected, since the RCA presented a
78
80
72
72
70
69
60
50
40
30
20
10
0
0
25
50
% Replasement of Sand by Fine RCA
75
Fig. 11: Effect of fine RCA on 28 days compressive strength of SCC with 50% replacement of coarse RCA
100
90
80
70
71
71
69
63
60
50
40
30
20
10
0
0
25
50
% Replasement of Sand by Fine RCA
75
Fig. 12: Effect of fine RCA on 28 days compressive strength of SCC with 75% replacement of coarse RCA.
specimens at 7 and 28 days. In this Table, the percentages
of
compressive
strength obtained at 7 days (R7)
compared with 28 days compressive strength (R28) was
also shown.
In addition, Figs. 9, 10, 11 and 12 show the effect of
using coarse and fine RCA on the compressive strength
at 28 days. In general, the compressive strength of the
studied mixes after 28 days ranged from 63MPa for mix No.
13 to 87MPa for mix No. 1, i.e. high strength concrete.
As shown in Table 5 and Figures (9, 10, 11 and 12), the
compressive strengths at 28 days decreased with
increasing of the percentage of coarse RCA used by 8, 10
and 18 % for replacements percentages 25, 50 and 75 %
respectively. Also, it is clear, that the using of fine RCA
has a significant effect on the compressive strengths at
7 and 28 days. It was observed that the replacement of
fine RCA resulting in significant reduction in the
compressive strength. It was also found that the all mixes
achieved at 7 days 70-72% of the compressive strength
CONCLUSIONS
REFERENCES
1.
2.
3.
4.
5.
6.
7.
8.
9.
473
474