Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Research Paper
Received: 7th May 2008; Revised: 13th December 2008; Accepted: 15th December 2008
Abstract: This research studied the effects of continuous and intermittent aeration on
submerged aerated bio filter (SAB) reactor. Three reactors were set up parallel to treat
artificial grey water by using sucrose: C12H22O11 with concentration of 300 mg COD L-1.
The bio ball media was used as support material to attach microorganisms. All reactors
were operated under batch and continuous conditions. Air supply to each reactor was
continuous, two hours on and off intermittent and four hours on and off intermittent
modes. Up flow rate of 0.048 m3 day-1 and air flow rate of 3.5 L h-1 were applied for
continuous reactor. The results showed that all reactors have no significant differences
on removal efficiency of COD (81-87%) as well as DO concentration and ammonium
removal.
Keywords: Ammonium, Aerated treatment, bio ball media, COD, grey water
INTRODUCTION
Domestic wastewater is estimated to contribute about 70 % of organic loading in rivers in
urban areas in Indonesia. As example, the Citarum River as the main water resource of Saguling
Dam, West Java contributes about 260 ton of domestic wastewater every day and increasing
COD, BOD, nitrogen and phosphate every year from 2002 until 2005 in both dry and rainy
seasons [1-2] around the Saguling Dam. The management system of domestic wastewater in
urban areas generally consists of centralized system and decentralized system. The centralized
system collects the wastewater and then transports it through the sewer systems to the domestic
wastewater treatment plant, while the decentralized system treat the waste water on site usually
in small scale, such as septic tank and pit latrine. Most of domestic wastewater in Indonesia
comes from grey water from washing, bathing, kitchen, which is flowing through the sewer or
drainage system without treatment. This condition increases the pollution of the water body,
169
Journal of Applied Sciences in Environmental Sanitation, 3 (3): 169-175.
Prayatni Soewondo and Andik Yulianto, 2008.The Effect of Aeration Mode on Submerged Aerobic Bio Filter Reactor
for Grey Water Treatment.
.
which is shown by some parameters like the decreasing of dissolved oxygen concentration and
the increasing of turbidity concentration, organic material and other materials. The quality of grey
water in Indonesia from some cities show that the concentration range of some parameters like
organic loading, TSS, ammonium, and oil & grease are 300-317 mg COD L-1, 23-200 mg L-1, 2-10
mg L-1, 71-123 mg L-1 [3-5]. In general, 47% of organic material in grey water is contributed by
domestic water, 26% of suspended solid, 12% of total nitrogen and 67% of total phosphate [6].
Attached growth reactor under an aerobic condition is one alternative technology to treat
wastewater, for example a submerged aerobic bio filter (SAB). This system has higher efficiency
than active sludge systems, especially for low organic loading [7]. However, compared to
anaerobic conditions, its more expensive in energy use (for its continuous aeration) and the
organic degradation is not always significant. The SAB reactor consists of aeration system to
supply the air and a fixed media. Aeration in SAB reactors are intends to give air to biological
metabolism under aerobic condition, stabilize the biological process, and to avoid retaining on
media by increasing the air flow rate. The range of air flow rate is between 5-15 Nm3 h-1.m2. The
fixed media is used to attach microorganism which then work as a bio film; it can be submerged
or floated under the water, depends on the operating system chosen. The COD removal is done
better with floating media in SAB reactors than submerged media [8]. The intermittent aeration in
SAB system could reduce the use of energy when the aeration system is turned down, especially
at night [9]. However, little was known for the effect of intermittent aeration to the removal
efficiencies of organic matter and some other parameters, such as dissolved oxygen, ammonium
and phosphate. Therefore, this research attempted to compare the capacity of SAB reactors on
reducing COD, ammonium and phosphate on different conditions of aeration time.
MATERIALS AND METHODS
The entire research was performed at the Water Research Laboratory of Environmental
Engineering Study Program of ITB, using three reactors under aerobic conditions. These
experiments used artificial domestic wastewater using sucrose: C12H22O11 as organic compounds
with concentration similar to 300 mg COD L-1. The microorganisms were obtained from septic
tanks and sewerages around Ganesha Street in Bandung, West Java, Indonesia.
During the acclimatization, 400-500 mg L-1 of glucose was used as carbon source while
aqueous solution of NH4Cl, KH2PO4, FeSO4.7H2O, MnSO4, and Ca(OH)2 was used as nutrient
source, with COD:N:P ratio equal to 100:5:1. After acclimatization phase, the reactors were run
under batch and continuous condition using sucrose with COD concentration 300 mg L-1 and
Compost (NPK) with composition of NH4 8,30%, NO3 6,70%, P2O5 9%, K2O 20%, MgO 2%, and
FeSO4.7H2O. Each reactor was operated in different conditions: a continuous aeration, two hours
on and off aeration and four hours on and off aeration.
Under the continuous condition, the reactor was operated up flow with flow rate of 0.048 m3
-1
day and air flow rate of 3.5 L h-1. The reactor is 14 cm in diameter, 180 cm in height, and 18
liters in volume (Fig. 1). The support material for attaching the microorganism was bio ball which
was made of polypropylene with diameter 3.33 cm, height 2.6 cm and weight 4.7 0.2 g. The
support media is filled to 90 cm and the sampling point took each 30 cm in width.
170
Journal of Applied Sciences in Environmental Sanitation, 3 (3): 169-175.
Prayatni Soewondo and Andik Yulianto, 2008.The Effect of Aeration Mode on Submerged Aerobic Bio Filter Reactor
for Grey Water Treatment.
.
Prayatni Soewondo and Andik Yulianto, 2008.The Effect of Aeration Mode on Submerged Aerobic Bio Filter Reactor
for Grey Water Treatment.
.
(2)
t C B
Where: rSCOD= rate of COD removal (hour. mg TSS)-1
C = reduction concentration of COD in period range (mg L-1 COD)
t = period range (tend t0) (hour)
CB = biomass concentration (mg L-1 TSS)
RESULTS AND DISCUSSION
Table 1 shows the COD removal on different aeration time under batch experiments. The
initial concentration of each batch reactor was 300 mg L-1 SCOD and achieved the steady state
condition after 18 hours. Based on equation (1) and (2), the COD degradation in batch reactor
were about 86 % 2 % with removal rate of COD: 0.013 h-1 for continuous aeration, 0.014 h-1
for both 2 and four hours intermittent aeration. This shows that under batch condition the aeration
time has no significant effect to the SCOD removal rate.
Table 1: COD removal on different aeration time under batch experiments
Time, hour
0
3
6
9
12
15
18
Continuous
aeration
300
210
80
58
42
40
28
The COD removal on different aeration time under continuous experiments was shown in
Table 2. Even though the efficiency of COD degradation under 4 hour intermittent aeration can
attain to 87 % , which is higher than continuous aeration (83%) and 2 hour intermittent aeration
(81%), yet there is no significant effect to the COD removal rate. The average COD removal rate
of every reactor is 0.034 h-1.
172
Journal of Applied Sciences in Environmental Sanitation, 3 (3): 169-175.
Prayatni Soewondo and Andik Yulianto, 2008.The Effect of Aeration Mode on Submerged Aerobic Bio Filter Reactor
for Grey Water Treatment.
.
Time, hour
Influent
3
6
9
12
15
18
345
300
330
367
335
346
The DO and Ammonium concentration is one important factor that affected the
microorganism during the experiment. Table 3 shows the profile of DO concentration in each
sampling points in all reactors.
Table 3: The profile of DO concentration in each sampling points under continuously experiments
No
Length,
cm
1
2
3
30
60
90
Average
continuous
aeration
4.35
4.48
4.87
4.56
The average DO concentrations for all reactors can attain to 4 mg L-1 and the concentration
increase by staging the sampling points in continuous aeration and two hours intermittent
aeration. In this research, the lowest averaging DO concentration is attained by two hours
intermittent aeration which only achieved a DO concentration of 4 mg L-1 because of limited
diffusion factor on the bio film. The limiting factors of reaction in suspension reactors is causing
DO concentration only achieveing 2-3 mg L-1 [11-12]. The low concentration of DO by using two
hours intermitten aeration shows the high activities of the microorganism. During the four hours
off aeration time, the DO concentration inside the reactor decreased because there was not
enough oxygen supply, especially after three hours long idle time. In contrary, the DO
concentration in the four hours intermittent aeration is relatively stable around 5 mg L-1 because
of the continuous aeration.
Table 5 shows the profile of Ammonium concentration in each sampling points under
continuous experiment. The ammonium concentration increases by staging the sampling points in
reactors with intermittent aeration. Theoretically, under aerobic condition ammonium will change
through nitrification process into nitrate and nitrite which then causes the decreasing of
ammonium concentration in the effluent. However, four hours intermittent aeration had the lowest
efficiency in ammonium removal even tough it used continuous aeration. This could be happen
173
Journal of Applied Sciences in Environmental Sanitation, 3 (3): 169-175.
Prayatni Soewondo and Andik Yulianto, 2008.The Effect of Aeration Mode on Submerged Aerobic Bio Filter Reactor
for Grey Water Treatment.
.
because the powder of NPK goes up flow together with the flow of air. A possible short circuit
between bed and bio was created by continuous aeration and four hours intermittent aeration.
Intermittent aeration time could reduce the short circuit possibility, happened in two hours
intermittent aeration time. The highest ammonium removal occurred December 2008 (Table 6),
because the biomass accumulates around the second sampling points so a short circuit flow
could be avoided.
Table 5: The profile of Ammonium concentration in each sampling point for continuous reactor
Length,
cm
30
60
90
Average
No
1
2
3
Table 6: The removal of COD and Ammonium and the increasing of DO concentration
No
1
2
3
Item
Removal of COD, %
Removal of Ammonium, %
Increasing of DO, %
Comparison between the submerged aerated bio filter (SAB) and Biological Aerated Filter
(BAF) [8, 13] showed that the SCOD removal achieved 80 % and the maximum ammonium
degradation achieved 50 %.
CONCLUSIONS
Intermittent or continuous aeration by influent concentration of 300 mg/L COD and 2.5 mg L-1
ammonium has no significant effect to the rate of organic removal under Submerged Aerated Bio
filter reactor. The average COD removal for continuous aeration, two hours and four hours
intermittent aeration are 83 %, 81 % and 87 %, respectively. The lowest dissolved oxygen
occurred in two hours on and off aeration which is around 4 mg L-1. Aeration mode affected the
efficiency of ammonium removal. Efficiency of ammonium removal for continuous aeration, two
hours and four hours intermittent aeration are 75 %, 61 %, and 60 %, respectively.
References
1. Soewondo, P., 2006. The Concentration of BOD, N-Total and P-Total During Dry and Rainy Seasons
in Saguling Dam, West Java, Indonesia, 2nd International Conference on Environmental and
Urban Management, Science, Nature and Justice, August 3-4, Semarang, Indonesia.
2. Soewondo,P., 2006. The Influence of Organic Loading in Saguling Dam, West Java, Indonesia,
International Seminar-Workshop on Integrated Water Resources Management, September 4-
174
Journal of Applied Sciences in Environmental Sanitation, 3 (3): 169-175.
Prayatni Soewondo and Andik Yulianto, 2008.The Effect of Aeration Mode on Submerged Aerobic Bio Filter Reactor
for Grey Water Treatment.
.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
175
Journal of Applied Sciences in Environmental Sanitation, 3 (3): 169-175.
Prayatni Soewondo and Andik Yulianto, 2008.The Effect of Aeration Mode on Submerged Aerobic Bio Filter Reactor
for Grey Water Treatment.
.
176
Journal of Applied Sciences in Environmental Sanitation, 3 (3): 169-175.