Sei sulla pagina 1di 60

We reserve all rights in this document and in the information contained therein.

Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

Typical Project Procedure


for use of
SmartPlant Instrumentation
with System 800xA

Based on

Prep.

: C R Rogers

25Feb08

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

Resp. dept.

- SPI Demonstration

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

1
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

TABLE OF CONTENTS

INTRODUCTION
1.1
1.2

RELATED ABB DOCUMENTATION ....................................................................................................... 5


TERMS AND ABBREVIATIONS ............................................................................................................... 6

PURPOSE AND SCOPE


2.1

SCOPE .................................................................................................................................................... 7

PREREQUISITES

3.1 SPI ADMINISTRATION .......................................................................................................................... 8


3.1.1
SPI Database ................................................................................................................................. 8
3.1.2
Browser Archiving........................................................................................................................ 8
3.1.3
Hosting, Software Administration and Support ........................................................................ 8
3.2 ABB ....................................................................................................................................................... 9
3.2.1
Remote Access............................................................................................................................... 9
3.2.2
Local Printing................................................................................................................................ 9
3.3 SECURITY .............................................................................................................................................. 9
3.3.1
Local Network Access................................................................................................................... 9
3.3.2
Remote Client Access ................................................................................................................... 9
4

INSTRUMENT TAGGING AND DATA STORAGE

11

4.1 TAGGING AND PARAMETERISATION OF ICSS OBJECTS .................................................................. 11


4.1.1
Minimum Object Parameter Requirements............................................................................. 12
4.1.2
Parameter Definition .................................................................................................................. 12
4.1.3
Non-Instrument Object Oriented Primary Tagging Parameter Definition .......................... 12
4.2 OBJECT DEFINITIONS ......................................................................................................................... 13
4.3 PROCESS DATA ................................................................................................................................... 14
4.4 INSTRUMENT INDEX BROWSER VIEWS ............................................................................................. 14
5

CONTROL/FUNCTION BLOCK DATA POINTS

ABB CONFIGURATION TOOL


6.1

ERROR! BOOKMARK NOT DEFINED.


16

PROCESS ENGINEERING TOOL INTEGRATION (PETI) ..................................................................... 16

ICSS PANELS AND WIRING


7.1
7.2
7.3
7.4
7.5
7.6
7.7
7.8

17

STRUCTURE AND CABLING................................................................................................................. 17


FIELD TERMINALS AND IO MODULES............................................................................................... 17
CROSS WIRING.................................................................................................................................... 18
SIGNAL TYPE AND MODULE ASSIGNMENT ....................................................................................... 18
EQUIPMENT IDENTIFICATION/NUMBERING...................................................................................... 19
REMOTE IO PANELS ........................................................................................................................... 19
SERIAL IO ........................................................................................................................................... 19
FOUNDATION FIELDBUS ..................................................................................................................... 19

Based on

Prep.

: C R Rogers

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

- SPI Demonstration

25Feb08

Resp. dept.

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

2
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

SPI BROWSERS AND REPORTS


8.1
8.2
8.3
8.4

20

INSTRUMENT DATA REPORTS ............................................................................................................ 20


PANEL AND WIRING REPORTS ........................................................................................................... 20
LOOP DIAGRAMS ................................................................................................................................ 20
SPI PREFERENCES .............................................................................................................................. 20

WORKFLOW PHILOSOPHY AND PROCEDURES


9.1

21

ICSS PANELS AND WIRING ................................................................................................................ 22

10 CHANGE CONTROL

23

10.1 ARCHIVES AND FREEZES,................................................................................................................... 23


10.2 SPI REPORT REVISION CONTROL ..................................................................................................... 23
10.3 IO ADDITION AND DELETION ............................................................................................................ 23
10.3.1 IO Addition.................................................................................................................................. 23
10.3.2 IO Deletion .................................................................................................................................. 24
10.4 SPI STATUS FIELD .............................................................................................................................. 24

APPENDIX A SPI Fields and 800xA Parameters


APPENDIX B Tag Browsers and Reports
APPENDIX C Control Type Parameters Listings
APPENDIX D Panel and Wiring Reports
APPENDIX E IO Hardware Types
APPENDIX F Process Flow Diagram

Based on

Prep.

: C R Rogers

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

- SPI Demonstration

25Feb08

Resp. dept.

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

3
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

REVISION RECORD & HOLDS & DISCREPANCIES

Revision
Rev

Para.

0.1
1.0

All
All

Description
Draught for Internal Comment
Initial Issue

Date

By

Check

Appv

28Feb08
4Mar08

CRR

DJD

Holds and Discrepancies


No.

Section

Description

Based on

Prep.

: C R Rogers

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

- SPI Demonstration

25Feb08

Resp. dept.

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

4
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

INTRODUCTION
In many projects ABB are required to utilise or interface to Intergraph SmartPlant
Instrumentation (SPI) for the definition of requirements for Control, Safety and Monitoring
System (ICSS). This may include design and definition of general instrumentation, field
wiring, panels, IO allocation and wiring.
A project SPI database may be
administered/owned by an end user, an EPC, by ABB or a third party.
In some projects ABB may use semi-automated configuration tools in order to minimise
engineering effort and improve configuration efficiency. These tools provide automatic
extraction of data from SPI and auto-configuration of ICSS control objects and IO
arrangements. In other projects automated tools may not be used. In both cases however,
the location and usage of data storage in SPI needs to be agreed.
This procedure is intended to define SPI related working and interface procedures for the
SPI engineering authority and ABB during the feed and execution stages of a project. It
includes references to ABB tools and methods for the efficient configuration of a typical
Control, Safety and Monitoring System.
It should be noted that each customer, Owner/Administrator may have different
requirements and standards when utilising SPI. A review and confirmation of the interface
will be required for each project in order to establish the relationship between SPI definition
and ICSS configuration and agree project responsibilities and procedures between parties.
The review will lead to the generation of a project specific procedure.

1.1

RELATED ABB DOCUMENTATION


The following document is a general guide in the utilisation of SPI for ICSS projects. Some
aspects may not apply to a particular project.
ABB Document Reference
50019-N02
3BUA00184R501

Title
ABB Guidelines for SmartPlant Instrumentation for
Automation Engineering
Process Engineering Tool Integration,
Configuration and Operation

Based on

Prep.

: C R Rogers

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

- SPI Demonstration

25Feb08

Resp. dept.

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

5
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

1.2

TERMS AND ABBREVIATIONS


EPC
ICSS
ICSS-E
SPI-E

DDS
FDS
PETI
PMC
PQ
SPI
SPI-A
UDF

Engineering Procurement Contractor


Integrated Control and Safety System
The organisation responsible for design and configuration of the ICSS
The organisation normally responsible for SPI engineering,
instrumentation and process data definition, and field instrumentation
and cabling within SPI (e.g. Owner/Operator or EPC or ABB or third
party or a mixture, according to the specific contract)
Detail Design Specification
Functional Design Specification
Process Engineering Tool Integration an ABB tool interfacing
between SPI and system 800xA
Project Management Contractor
Refers to the ABB standard Project Query system
SmartPlant Instrumentation (INtools)
SPI system administrator
User Defined Field

Based on

Prep.

: C R Rogers

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

- SPI Demonstration

25Feb08

Resp. dept.

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

6
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

PURPOSE AND SCOPE


This document is intended as a general guide to the SPI-E/Operator/ABB working
procedure in respect of SmartPlant Instrumentation. It sets out the various requirements
including a definition of the relationship between SPI database fields and various ICSS
device parameters and the procedural order of working. In the area of panels, wiring,
cables etc. this procedure defines relationships between IO type and standardised IO
hardware format.
The document extensively addresses aspects of work flow and the working relationship
including data location definitions, sequence of working, responsibilities, change
identification and control, implementation in the ICSS etc.
The intention is to provide guidance during project start-up to allow the SPI related
interfaces to operate efficiently for the duration of the project.

2.1

SCOPE
This procedure defines a SPI-E / ABB working arrangement. It does not include instructions
in the basic functions of SPI. It does include use, setup and operational definitions for
project specific key functions and requirements.

Based on

Prep.

: C R Rogers

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

- SPI Demonstration

25Feb08

Resp. dept.

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

7
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

PREREQUISITES
It is assumed that personnel working in the area of SPI have the appropriate training and
exposure to SPI.
The SPI base version and patch version need to be known at the earliest stage of the
project in order to allow the appropriate ABB tools (if to be used) to be selected.

3.1

SPI ADMINISTRATION

3.1.1

SPI Database
The SPI Administrator (SPI-A) will provide and maintain the project SPI database. This
may be on a local or a remote server platform. The SPI-A shall provide the SPI-E
personnel and ABB users with necessary SPI access capability.
Access may be via a local network, terminal server, Citrix or some other mechanism.
To allow access to the SPI server, each ABB user will be registered with SPI-A support
and will be provided with a unique user name and password. Additionally each user may
be required to use a Secure ID or some other method to ensure restricted and
authorised access to SPI data and panel/cable/wiring design functions.

3.1.2

Browser Archiving
All browsers used in the extraction of data from the SPI database are required to have
archiving functionality. This archiving capability will be set up by the SPI-A.
Archiving is used for establishing records of database content as required, and can be
the basis for difference reporting when needed.

3.1.3

Hosting, Software Administration and Support


Responsibility for SPI administration normally lies with the SPI host. The identity of the
host will vary according to individual project arrangements. The host could the
Operator/Owner, an EPC, a PMC/third party central sourcing facility in a large multiple
EPC project (MAC project), or ABB. Normally all SPI licensing, maintenance and
administration is provided by the host.
Many SPI based projects are likely to have remote clients. Access may be via Citrix,
Terminal Server or other mechanisms. For these clients the host will provide all remote
access functionality.

Based on

Prep.

: C R Rogers

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

- SPI Demonstration

25Feb08

Resp. dept.

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

8
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

The hosts SPI-A SPI support contact shall be nominated at the commencement of the
project. In the event of problems with access or SPI service, users will have free access
to the SPI-A support contact directly in order to raise or discuss issues.
3.2

ABB
Normally each ABB SPI user will be equipped with a PC having Windows XP 2003 SP2 as
the operating system with a minimum of 1 GB of RAM. These may be direct SPI clients to
a networked SPI server, in which case they are loaded with the appropriate SPI client;
otherwise, if a remote Citrix based client, there is no requirement for any specific
application package to be loaded to the SPI users equipment, all functionality being
available via the link.

3.2.1

Remote Access
ABB users shall log on to the project SPI database via the designated route as required
using the SPI user names and passwords issued by SPI-A. Refer to preceding
paragraphs.

3.2.2

Local Printing
Where Citrix is the chosen method of access each ABB user will nominate a default
local printer for SPI outputs and reports, accessible from the PC. The SPI-A will set up
the remote server with the ability to output to these default printers as requested by use
of the appropriate printer driver.

3.3

SECURITY
Various levels of access security may exist, depending on the user client access method.
SPI standard login will always be required.

3.3.1

Local Network Access


Where a local Intranet or an isolated network is used, simple SPI client access will be
required.

3.3.2

Remote Client Access


Terminal Server (Remote Desktop) access may be provided, normally requiring user
name and password for access.
Citrix is a commonly used method of providing remote, secure, multiple, individually
authorised SPI access. This access may be with or without Secure ID (or equivalent).

Based on

Prep.

: C R Rogers

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

- SPI Demonstration

25Feb08

Resp. dept.

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

9
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

After achieving access to the SPI server, SPI access is controlled by the standard
Intergraph method of user name and password. This is administered by SPI-A.

Based on

Prep.

: C R Rogers

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

- SPI Demonstration

25Feb08

Resp. dept.

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

10
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

INSTRUMENT TAGGING AND DATA STORAGE


The typical SPI project comprises a list of tag numbers and associated data. SPI entries
are based on the instrument tag and this forms the primary database field. This information
is stored in the Instrument Index Standard Browser
Definition of each entry may vary according to the users requirements or view of how to
utilise SPI. Many users include all instrumentation tags as entries in SPI. These may
include field instrument tags associated IO points and soft (e.g. alarm) tags all included
under a loop definition tag. Other users may only include a list of IO tags and utilise UDF
fields to define control system tagging. Each project must agree this tagging arrangement
at the outset.
Control system range data (e.g. engineering units and range) is commonly stored by tag in
SPI Process Data and accessed via the Process Data Browser. This may include alarm
set and trip points. Control system data may also be stored under and available via the
Instrument Index Standard Browser in user defined fields.
The Control System Tag field is available via the Control System / Control System Tag
Browser. This tag is commonly used when allocating IO channels. This browser relates
Tag Number with Control System Tag.
All storage locations of ICSS data must be agreed at the commencement of any project
involving SPI.
Refer to Appendix B for examples of browser content and views.

4.1

TAGGING AND PARAMETERISATION OF ICSS OBJECTS


ICSS objects are the entities configured in the control system that represent either external
instrumentation (i.e. transmitters, valves, detectors etc.) or IO between the ICSS and other
systems. The configuration in the ICSS is defined by the Control Type designation related
to the tag number.
The Instrument Tag needs to be applied in the ICSS as the configured object tag. It is
these tags that will appear on the faceplates of the instantiated objects within the ICSS.
Single input or single output objects (pushbuttons, indicators) may have the same IO and
object Tag Number; they are generally the same in SPI. The Control Type defines the
object type used in ICSS configuration.
Multiple IO ICSS objects (valves, transmitters with tagged alarms etc.) have the same base
numeric tag reference with different leading and trailing alpha characters for each element.
The ICSS object representing the field instrument or device could be a separate SPI entry

Based on

Prep.

: C R Rogers

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

- SPI Demonstration

25Feb08

Resp. dept.

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

11
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

with the same numeric core, the object then takes the SPI tag (e.g. XV for a valve). One
control object is configured in the ICSS for these grouped tag instances.
Control loop groupings (e.g. conventional control loops of say transmitter, PID function and
control valve) are defined by the Loop Tag field entries.
4.1.1

Minimum Object Parameter Requirements


The minimum data required in order to commence engineering a project i.e. to allow
configuration in 800xA, is the tag name and instrument type.
This allows the project to establish tagged objects and proceed with engineering the
application, with graphics generation and to download to soft controllers for early proof
and testing.
At this early project stage objects are instantiated into 800xA with all other customer
based parameters at default values. Later in the project, as specific data becomes
available, parameters such as engineering range and alarm limits can be updated, for
example by using the PETI tool. Panel, cabling, wiring etc. can follow.

4.1.2

Parameter Definition
In the ICSS, the parameters associated with tagged objects (descriptor, range, alarm
levels etc.) need to be applied to the tagged, instantiated objects. Parameters are held
in SPI as other field entries against Tag Number records. Parameter data will be
extracted via SPI browsers or directly from the underlying Oracle tables by ABB special
tools (typically PETI).
For a single IO point objects Tag Number, the associated parameters are entered in the
appropriate fields for each entry.
For multiple IO objects (defined by multiple entries of the same numeric tag core and by
Control Type) it is critical that the associated parameter data is entered consistently in
pre-defined locations. For these types of objects parameter data will need to be
processed to extract the data ready for configuration within the ICSS. If data is not
entered consistently in pre-defined locations within SPI then it may not be collected
efficiently ready for ICSS configuration.

4.1.3

Non-Instrument Object Oriented Primary Tagging Parameter Definition


In a case where the SPI database is simply a list of IO points tagged in the CMPNT_NAME
field, the ICSS object tag may not be a primary SPI entry. A user defined (UDF) Soft Tag
field needs to be used for ICSS object tag definition, see table below. In this case it is
necessary to define explicitly the location for storage of associated ICSS parameter
definition data. This is a non-preferred usage of SPI.

Based on

Prep.

: C R Rogers

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

- SPI Demonstration

25Feb08

Resp. dept.

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

12
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

The following table defines possible IO showing example (Tag Number) entries against
which Soft Tag object parameters are to be entered.
Object
Description
On/Off Valve
Motorised Valve
Process Controller
Flow Alarm
LL Flow Indication
Package Alarm
ICSS/ESD Intertrip
ESD/ICSS Intertrip

ICSS Object
Soft Tag (UDF)
ESDV, HSD,
SDV
XV
FFIC, FIC, PDIC,
TIC
FAL
FLL
UA
XS
XS

Database Entry for


Object Parameter Definition
Description
Entry Tag
(CMPNT_NAME)
SOV output
XSOV, ESOV,
SSOV, etc.
Valve Open Command
XHSO
Analogue Input
FT, PDT, TT etc.
Switch Input
Analogue Input
First Input
ICSS Input
ICSS Output

FSL
FT
UAnnnnn-1
XS
XS

This table is not comprehensive and must be confirmed specifically for each project.
OBJECT DEFINITIONS

4.2

Each SPI tag entry should have a Control Type defined. Control objects (transmitters,
valves etc.) are configured in the ICSS as various Control or Function Blocks based on a
Control Type. Generally the control requirements for each Control Type will be defined in a
project specific document. At the commencement of each project these control
requirements must be defined and agreed for each Control Type.
For each control object, the Control Type (i.e. which Control/Function Block is to be used)
is defined in a field in SPI. Each Control Type is preconfigured as a standard library object
and copied in the ICSS for each tagged instance required. The specific parameter values
(Name, Description etc.) are then applied for each tag instance.
Control Types may be simple instruments (e.g. transmitter, valve) or may be a complex
control loop requirement.
Complex definitions may be detailed in a Control Narrative. Control Narratives are
normally produced by ABB in response to a customers control specification and provide a
detailed, approved solution for use in 800xA.
A project that has control requirements based on Control Types may specify as shown in
Appendices A (field named Control Type) and with specific parameterisation as shown in
Appendix C.

Based on

Prep.

: C R Rogers

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

- SPI Demonstration

25Feb08

Resp. dept.

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

13
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

4.3

PROCESS DATA
The SPI process data area may be the location where the SPI-E defines instrument ranges
and sometimes analogue alarm levels.
Data is available via the SPI Process Data
Browser. Alternatively this data may be provided in other tables and browsers, as
determined by the SPI-E

4.4

INSTRUMENT INDEX BROWSER VIEWS


Generally ABB will define a set of Instrument Index Standard Browser and Process Data
views in order to view the appropriate data. These browsers will include all of the SPI
based data required for ICSS configuration. Refer to Appendix B for examples of browser
outputs. Content of all browsers can be checked by examination of the browser
configuration in SPI.
The ABB preferred method of ICSS configuration is to use automated tools e.g. ABBs
PETI application. In these cases browsers still provide a method of viewing and manually
configuring SPI data but are not the primary mechanism for extraction and ICSS
configuration. Refer to Section 6 on ABB tools.
For non-ABB automated data extraction these browsers will be used to provide tabular
output that will form the basis for ICSS object configuration.

Based on

Prep.

: C R Rogers

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

- SPI Demonstration

25Feb08

Resp. dept.

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

14
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

THE SPI / SYSTEM 800XA RELATIONSHIP


The System 800xA format comprises two area of configuration: engineering control
application and hardware definition. This relates to SPI areas of tagged objects definition
(available via browsers) and equipment, panel, cabling design (the wiring module).
System 800xA control application engineering and hardware definition can be separately
configured as required by a project schedule, in line with the customer expectations of data
availability. This means that tagged objects and applications can proceed based on
minimum information quite separately from hardware definition. The two areas become
linked at the time of IO allocation. Thus two separate streams of project scheduling can be
followed. Refer to the process flow diagram provided in Appendix F.
This approach provides that tagged objects and applications can commence immediately
based on minimum information at project commencement, separately from hardware
definition. Refer also to paragraph 4.1.1.

5.1

CONTROL/FUNCTION BLOCK DATA POINTS


Each Control or Function Block type is populated with data extracted from SPI according to
its parameter requirements. Any parameters not included in the definition tables are left at
default setting. Function block parameters listed are those detailed in the associated
definition document.
Refer to Appendix C for Control Type parameters listings.

Based on

Prep.

: C R Rogers

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

- SPI Demonstration

25Feb08

Resp. dept.

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

15
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

ABB CONFIGURATION TOOL


ABB have a semi-automated tool for use when configuring System 800xA in relation to SPI.
PROCESS ENGINEERING TOOL INTEGRATION (PETI)

6.1

PETI is a standalone application tool that provides seamless data exchange between
Intergraph Corporations INtools 6.0 or SmartPlant Instrumentation (SPI) 7.0 (and later)
and ABB's 800xA system.
INtools/SPI manages and stores the history of the object definition and hardware design of
the control system and provides a single source of plant information that can be easily
accessed and updated. It ensures consistency across different instrument tasks and
deliverables.
PETI provides data exchange between basic, process and instrumentation engineering
function and the control engineering function. The product keeps the process and control
engineering data consistent over the entire life cycle of a plant (bidirectional data
exchange, single point of data exchange).
PETI relates tag and field data in SPI with tagged objects and parameters in 800xA
seamlessly by means of mapping techniques. PETI configures System 800xA objects and
populates parameters with SPI data automatically, without manual intervention. PETI is
used for the whole life of the plant and can reverse update SPI data, based on value
changes of 800xA parameters in order to keep SPI data aligned with the control system.
Refer to section 1.1 for reference documentation on PETI.

Based on

Prep.

: C R Rogers

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

- SPI Demonstration

25Feb08

Resp. dept.

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

16
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

ICSS PANELS AND WIRING


The following procedures are a basic definition to be reviewed and confirmed for each
project. Refer to Section 1 - Introductiion
ICSS_E will design ICSS panels and panel wiring in SPI, initially producing a set of
reference equipment. Specific instances are then produced for each ICSS panel required
on the project.
All panel and equipment design will be in accordance with the established/agreed project
standards.

7.1

STRUCTURE AND CABLING


The ICSS panels may be subdivided into various groups as required, for example Process
Control System (ICSS), Fire & Gas System (FGS), Process Shut Down (PSD), and
Emergency Shut Down (ESD). The general procedure for developing and defining this area
of the project is as follows:

SPI-E will develop the Instrument Index for the project in the SPI database
ICSS-E will develop the ICSS structure based on information held in the SPI
database
ICSS-E will review this database to identify the quantity of IO and their signal types,
to determine the required system size and structure for each of these areas.
Depending on specific project responsibilities, SPI-E may develop the field cabling
for the project in the SPI database
ICSS-E will review this database to identify the field cabling and the signals
assigned to them, to determine the marshalling and termination requirements for
each ICSS area
This structure will then be built in the SPI database by ABB

This will be an ongoing task through the Detailed Design phase of the project.
Specific panel and rack design requirements will be defined within the relevant project
documents e.g. FDS, DDS, panel drawings etc.
FIELD TERMINALS AND IO MODULES

7.2

The procedure for developing and defining this area of the project is as follows:
Development of the ICSS marshalling and IO structure will be completed in the SPI
database by the ICSS-E.

Based on

Prep.

: C R Rogers

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

- SPI Demonstration

25Feb08

Resp. dept.

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

17
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

The marshalling field terminals will be matched to the cable type that will land on them.
ICSS-E will position these terminals in the relevant ICSS panel and will connect the
relevant multicore cables to them.
The IO modules will be added and positioned in the ICSS panels to accommodate the
signals presented on the marshalling field cables. Assignment of the IO signals to these
modules is to be completed by the ICSS-E, subject to agreement with ABB with respect to
any grouping preferences.
Only IO channels and terminals that are fully functional will be displayed and available for
tag allocation.
Appendix E provides details of the IO signal definition type that can be assigned to specific
IO module/marshalling combinations where there may be non-standard requirements e.g.
in an upgrade utilising old style IO hardware. Where standard ABB IO is utilised; no
conflict of IO Signal definition type to IO modules exists e.g. on S800 or S900 hardware
structures.
7.3

CROSS WIRING
Once the marshalling field cables are connected and the IO assignment has been
completed for each ICSS area, ABB will proceed with the cross wiring operation in the SPI
database, for the area.
This approach allows parallel working to occur between these tasks and will contribute to
meeting project schedules.
When the detailed design freeze point (refer to section 8) is reached for each ICSS area,
e.g. Process, Utilities Packages, FGS etc., wiring schedules are produced from and
archived in the SPI database, by ABB. These wiring schedules are one of the deliverables
from the SPI database for the building of the ICSS panels. An electronic copy of these is
required for operations during panel build. This will be generated by extraction from SPI.
After the design freeze point, any design changes made will be identified by comparing the
archived schedules with the new revisions by ABB.
Note: Cross wiring is to be installed and removed by ICSS-E, some changes to the SPI
database result in a prompt by SPI to remove, disconnect or remove wiring; this prompt
must not be accepted until appropriately agreed.

7.4

SIGNAL TYPE AND MODULE ASSIGNMENT


A set of loop typical drawings will be required for use during any project. These drawings
are required to show the interconnection from the field, through marshalling, to the IO
modules and to show the particular signal interface hardware required. Each loop typical
shall have a unique identification number, this identity is to be entered in an agreed SPI

Based on

Prep.

: C R Rogers

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

- SPI Demonstration

25Feb08

Resp. dept.

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

18
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

field against loop or tag identities. These loop typical drawings are used as the basis for
standardised loop hardware arrangements when assigning each instrument IO point.
The SPI database Instrument Index module has a field named System IO Type (available
from various modules); this field is used in the instrument properties and on the ICSS IO
module. The instrument engineering function will assign this field for the instruments and
assign this field to the IO modules, according to IO types and functions.
These fields determine which ICSS area the signal belongs to as well as connectivity to the
ICSS IO module.
Note: There is a relationship between the ICSS module, termination and marshalling
components - IO assignment must take these factors into account.
Appendix A details typical ICSS module parameter definitions related to SPI Field Names.
7.5

EQUIPMENT IDENTIFICATION/NUMBERING
During detailed design, the Instrument Engineering Function and ABB will agree the
identification numbers required on the items built in the SPI database. This will apply to
panels, controllers, modules, terminal strips, system cables etc. and will be inline with
project numbering philosophy document.
ABB and SPI-E will check that the identification numbers applied show as intended on SPI
generated reports and drawings, i.e. Loop drawings utilise many SPI fields and require
checking to ensure identification numbers appear fully and in the correct location.

7.6

REMOTE IO PANELS
Where used, these panels are a standardised build with pre-fitted terminals that accept
individual field cables. The procedure for remote IO panels is slightly different from other
panels.
Panels will be utilised and connected as required by SPI-E and ABB will add necessary IO
hardware, SPI-E will then allocate IO and ABB will complete the cross wiring.

7.7

SERIAL IO
Tagged objects should be included in SPI and will be configured as described above.
Serial interface cabling should be included in SPI cable details.
FOUNDATION FIELDBUS

7.8

Tagged objects should be included in SPI and will be configured as described above.
Cabling and fieldbus items should be included in SPI installation design.

Based on

Prep.

: C R Rogers

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

- SPI Demonstration

25Feb08

Resp. dept.

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

19
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

SPI BROWSERS AND REPORTS


Browsers and reports for ABB system design should be controlled and maintained by ABB.
All ABB developed browsers will be prefixed ABB and must not be modified by non-ABB
users.

8.1

INSTRUMENT DATA REPORTS


These are generated using the Instrument Index browsers. Examples are provided in
Appendix B.
PANEL AND WIRING REPORTS

8.2

Examples of Panel and wiring reports are provided in Appendix D.


LOOP DIAGRAMS

8.3

Loop diagrams are generated in SPI in accordance with project standard templates.
The Enhanced Smart Loop style is to be used. Loops are based on a set of project loop
definitions.
8.4

SPI PREFERENCES
SPI preferences are to be agreed at an early stage and pre-defined by SPI-A and either set
as SPI global definitions by SPI-A or set locally by users in accordance with standard
settings advised by SPI-A.

Based on

Prep.

: C R Rogers

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

- SPI Demonstration

25Feb08

Resp. dept.

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

20
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

WORKFLOW PHILOSOPHY AND PROCEDURES


The workflow described here is one possible approach and may be typical for many
projects. Final procedures for specific projects will be agreed, documented and established
at project commencement.
The nature of most project setups is that parallel SPI working (SPI Owner/ABB) will be the
norm, particularly in the area of panels and wiring. This requires careful control of working
areas between the various parties.
ABB would expect that SPI browsers are ready for the start of a project. At this point a full
set of browser reports are to be taken and archived at revision P0 as a base reference.
During the initial detail design stage, as each area or item of the plant is authorised for ABB
design, ICSS configuration will proceed based on the as-of-the-moment SPI data status. In
due course objects will be configured in ICSS systems and panels and wiring will be
designed and configured by ABB in SPI.
A good interface must exist between the various parties. The intention is that all parties will
interact constantly, generally via informal discussion, to ensure that project benefits from a
good exchange of information.
Ad-hoc changes in SPI by SPI-E or others should only impact ABB design if the affected
area has already been authorised for ABB design and actual ABB work in the SPI database
has started. If configuration has already taken place the following may apply:

Instrument Index Content


The differences may only be apparent when the next browser revision compares
are undertaken. Results of the compare will be analysed and differences identified
and appropriate actions agreed.

Panels and Wiring


Some detail changes (e.g. moving a tag to another multi-core cable pair, changing
the size of a multi-core cable) may be obvious when analysing panel and wiring
views.

SPI data freeze points will be agreed as part of the detail design phase. These will be the
major reference points for change identification. Freezes will be both hardware and
software and will not necessarily occur at the same time.
Appendix F provides a process flow chart for the procedures. The following is a breakdown
of the process:

Based on

Prep.

: C R Rogers

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

- SPI Demonstration

25Feb08

Resp. dept.

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

21
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

9.1

ICSS PANELS AND WIRING


ABB will design the ICSS panels and wiring based on the SPI database information created
by SPI-E. This will be in accordance with the established/agreed project standards. This
information will be accessed and used on an ongoing basis through detailed design up to a
SPI-E design freeze point. At this point SPI-E must cease work in this area (approximately
one day) until a set of Instrument, Wiring and Control System browsers has been archived
by ABB, thus capturing the design freeze data.
The archived documents are then available for identifying changes made after the design
freeze point.
A series of freezes and archives may be required, depending on individual project
requirements. These may be by Plant, Area, P&ID etc.
The Flow Diagram in Appendix F shows details of this design process.

Based on

Prep.

: C R Rogers

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

- SPI Demonstration

25Feb08

Resp. dept.

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

22
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

10

CHANGE CONTROL

10.1 ARCHIVES AND FREEZES,


A hardware and a software freeze will be agreed at order placement. At these freeze
points SPI-E will halt work for an agreed period (approximately one day) in the affected
areas such that ABB can take archive and panel production reports.
Hardware and panel production reports may be issued to the shop floor for panel build at
this stage. The project will progress and, if required, other freezes may be agreed in which
case the browsers are again run and archived. Archived reports will be compared and
differences identified.
For ICSS object definition the resulting archive comparison reports will indicate the
differences between the freeze points.
For panels and wiring the differences report will provide a definition of the physical changes
required to the built and wired panels where build has started.
Browser reports may be archived at any stage by ABB for interim check purposes.
10.2 SPI REPORT REVISION CONTROL
For each report, each archived version will have a unique revision and the archive date
included. The format of this revision will be P0, P1, P2 etc. These are applied
automatically by SPI each time an archive is made.
Using these revision identifications it will be possible to select the required comparison
reference versions.
10.3 IO ADDITION AND DELETION
IO points are defined as database records. Additions and deletions of IO requirements can
occur at any stage of the project and may have an impact on ICSS design, configuration
and build.
After a freeze has been instituted the archive will be used to identify changes.

10.3.1

IO Addition
IO additions can be identified by regular comparison of archived SPI browser reports.

Based on

Prep.

: C R Rogers

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

- SPI Demonstration

25Feb08

Resp. dept.

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

23
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

10.3.2

IO Deletion
Tags must not be removed from the database. Where a tag is not required for
implementation it is to be highlighted by SPI-E by annotating the Status field with
DELETED

10.4 SPI STATUS FIELD


This SPI field is used to indicate the status of each tag entry as follows:
Entry
DELETED
FUTURE
IMPL

ABB Interpretation
Deleted tag to be action'ed
No action, subject to release
Tag to be implemented

Other definitions may be required depending on project specific agreed procedures.

Based on

Prep.

: C R Rogers

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

- SPI Demonstration

25Feb08

Resp. dept.

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

24
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

APPENDIX A SPI Fields and 800xA Parameters


Tagging and Parameterisation of ICSS Objects
ICSS object tagging and parameter data is based on definitions given in the following table. This basic set of Instrument Index browsers is used
for general extract of data by ABB. The generated data file is then related to each specific Function Block / Type Circuit.
Usage of SPI fields tends to vary so all SPI field locations are to be individually confirmed at the commencement of each project.
Instrument
Tag Type

Analogue
Input

SPI
FieldName
(Configurable
name)

Intools/SPI
DatabaseFieldName
(Fixed)

Tag Number

CMPNT_NAME

Service

800xA Entry
Data Type

Entry

Responsible

N/A

String

N/A

SPI-E

CMPNT_SERV

Description

String

Max 48 chars***

SPI-E

Instrument Type

CMPNT_FUNC_TYPE_ID

N/A

String

N/A

SPI-E

Status

CMPNT_HANDLE_ID

N/A

String

N/A

SPI-E

P&ID

DWG_ID

N/A

String

N/A

SPI-E

DCS-RANGE-MAX

HiRange

Real

UOM

SPI-E

DCS-RANGE-MIN

LoRange

Real

UOM

SPI-E

DCS-RANGE-UOM

UOM

String

Max 5 chars

SPI-E

Name

String

Max 20 chars

SPI-E

Maximum DCS
Range
Maximum DCS
Range
DCS Range
Units
Soft Tag *
(Object)

SPI Table
Name

UDF_C11

800xA Property

Based on

Prep.

: C R Rogers

25Feb08

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

Resp. dept.

- SPI Demonstration

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

25
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

Instrument
Tag Type

SPI
FieldName
(Configurable
name)
Low Event
(Gap Control)
High Event
(Gap Control)

Intools/SPI
DatabaseFieldName
(Fixed)

800xA Property

800xA Entry
Data Type

Entry

Responsible

UDF_C18

Internal Variable

Real

UOM

SPI-E

UDF_C19

Internal Variable

Real

UOM

SPI-E

Low Low
Setpoint

PD_x_ALARM_LOW_LOW
or
UDF_C20 ****

AELevelLL

Real

UOM

SPI-E

Low
Setpoint

PD_x_ALARM_LOW
or
UDF_C21 ****

AELevelL

Real

UOM

SPI-E

High
Setpoint

PD_x_ALARM_HIGH
or
UDF_C22 ****

AELevelH

Real

UOM

SPI-E

High High
Setpoint

PD_x_ALARM_HIGH_HIGH
or
UDF_C23 ****

AELevelHH

Real

UOM

SPI-E

Control Setpoint

UDF_C24

Internal Variable

Real

UOM

SPI-E

UDF_C30

N/A

String

N/A

SPI-E

UDF_C31

N/A

String

N/A

SPI-E

InteractionPar

UDF_C101

InteractionPar

TransmitterPar

Max 20 chars

ABB

IOPar

UDF_C102

IO

IOPar

Max 20 chars

ABB

Control
Narrative **
Control
Type **

SPI Table
Name

Based on

Prep.

: C R Rogers

25Feb08

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

Resp. dept.

- SPI Demonstration

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

26
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

Instrument
Tag Type

SPI
FieldName
(Configurable
name)

Intools/SPI
DatabaseFieldName
(Fixed)

OutPar

UDF_C105

AEClass

SPI Table
Name

800xA Property

800xA Entry
Data Type

Entry

Responsible

OutPar

OutPar

Max 20 chars

ABB

UDF_C108

AEClass

Integer

1-9999

SPI-E

AEConfOE

UDF_C109

AEConfOE

Integer

0-4

SPI-E

AESevOE

UDF_C110

AESevOE

Integer

1-1000

SPI-E

AEConfLL

UDF_C112

AEConfLL

Real

0-4

SPI-E

AEConfL

UDF_C113

AEConfL

Real

0-4

SPI-E

AEConfH

UDF_C114

AEConfH

Real

0-4

SPI-E

AEConfHH

UDF_C115

AEConfHH

Real

0-4

SPI-E

AEFilterTime

UDF_C117

AEFilterTime

Real

secs

SPI-E

AEHysterisis

UDF_C118

AEHysterisis

Real

UOM

SPI-E

AESevLL

UDF_C120

AESevLL

Integer

1-1000

SPI-E

AESevlL

UDF_C121

AESevlL

Integer

1-1000

SPI-E

AESevH

UDF_C122

AESevH

Integer

1-1000

SPI-E

Based on

Prep.

: C R Rogers

25Feb08

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

Resp. dept.

- SPI Demonstration

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

27
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

Instrument
Tag Type

DigitalInput

SPI
FieldName
(Configurable
name)

Intools/SPI
DatabaseFieldName
(Fixed)

AESevHH

UDF_C123

AESevHH

P of PID Value

UDF_C141

I of PID Value

800xA Entry
Data Type

Entry

Responsible

Integer

1-1000

SPI-E

tba

Real

N/A

SPI-E

UDF_C142

tba

Real

N/A

SPI-E

D of PID Value

UDF_C143

tba

Real

N/A

SPI-E

Tag Number

CMPNT_NAME

N/A

String

N/A

SPI-E

Service

CMPNT_SERV

Description

String

Max 48 chars***

SPI-E

Instrument Type

CMPNT_FUNC_TYPE_ID

N/A

String

N/A

SPI-E

Status

CMPNT_HANDLE_ID

N/A

String

N/A

SPI-E

P&ID

DWG_ID

N/A

String

N/A

SPI-E

UDF_C30

N/A

String

N/A

SPI-E

UDF_C31

N/A

String

N/A

SPI-E

UDF_C101

InteractionPar

TransmitterPar

Max 20 chars

ABB

Control
Narrative **
Control
Type **
InteractionPar

SPI Table
Name

800xA Property

Based on

Prep.

: C R Rogers

25Feb08

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

Resp. dept.

- SPI Demonstration

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

28
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

Instrument
Tag Type

SPI
FieldName
(Configurable
name)

Intools/SPI
DatabaseFieldName
(Fixed)

IOPar

UDF_C102

AEClass

SPI Table
Name

800xA Property

800xA Entry
Data Type

Entry

Responsible

IO

IOPar

Max 20 chars

ABB

UDF_C108

AEClass

Integer

1-9999

SPI-E

AEConfOE

UDF_C109

AEConfOE

Integer

0-4

SPI-E

AESevOE

UDF_C110

AESevOE

Integer

1-1000

SPI-E

InNormal

UDF_C130

InNormal

Integer

0/1

SPI-E

AEConfDiff

UDF_C132

AEConfDiff

Integer

0-4

SPI-E

AESevDiff

UDF_C133

AESevDiff

Integer

1-1000

SPI-E
SPI-E

DigitalOutput

Tag Number

CMPNT_NAME

N/A

String

N/A

SPI-E

Service

CMPNT_SERV

Description

String

Max 48 chars***

SPI-E

Instrument Type

CMPNT_FUNC_TYPE_ID

N/A

String

N/A

SPI-E

Status

CMPNT_HANDLE_ID

N/A

String

N/A

SPI-E

P&ID

DWG_ID

N/A

String

N/A

SPI-E

Based on

Prep.

: C R Rogers

25Feb08

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

Resp. dept.

- SPI Demonstration

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

29
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

Instrument
Tag Type

SPI
FieldName
(Configurable
name)
Control
Narrative **
Control
Type **

Intools/SPI
DatabaseFieldName
(Fixed)

SPI Table
Name

800xA Property

800xA Entry
Data Type

Entry

Responsible

UDF_C30

N/A

String

N/A

SPI-E

UDF_C31

N/A

String

N/A

SPI-E

InteractionPar

UDF_C101

InteractionPar

TransmitterPar

Max 20 chars

ABB

IOPar

UDF_C102

IO

IOPar

Max 20 chars

ABB

AEClass

UDF_C108

AEClass

Integer

1-9999

SPI-E

AEConfOE

UDF_C109

AEConfOE

Integer

0-4

SPI-E

AESevOE

UDF_C110

AESevOE

Integer

1-1000

SPI-E

OutNormal

UDF_C131

OutNormal

Integer

0/1

SPI-E
SPI-E

Valve

Tag Number

CMPNT_NAME

N/A

String

N/A

SPI-E

Service

CMPNT_SERV

Description

String

Max 48 chars*

SPI-E

Instrument Type

CMPNT_FUNC_TYPE_ID

N/A

String

N/A

SPI-E

Status

CMPNT_HANDLE_ID

N/A

String

N/A

SPI-E

Based on

Prep.

: C R Rogers

25Feb08

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

Resp. dept.

- SPI Demonstration

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

30
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

Instrument
Tag Type

SPI
FieldName
(Configurable
name)

Intools/SPI
DatabaseFieldName
(Fixed)

P&ID

DWG_ID

800xA Entry
Data Type

Entry

Responsible

N/A

String

N/A

SPI-E

UDF_C30

N/A

String

N/A

SPI-E

UDF_C31

N/A

String

N/A

SPI-E

UDF_C36

Description

String

Max 20 chars

SPI-E

InteractionPar

UDF_C101

InteractionPar

ValvePar

Max 20 chars

ABB

IOPar

UDF_C102

IO

IOPar

Max 20 chars

ABB

SP

UDF_C104

Out

Control
Connection

Max 20 chars

SPI-E

AEClass

UDF_C108

AEClass

Integer

1-9999

SPI-E

AEConfOE

UDF_C109

AEConfOE

Integer

0-4

SPI-E

AESevOE

UDF_C110

AESevOE

Integer

1-1000

SPI-E

DeviceType

UDF_C135

DeviceType

Integer

1-4

SPI-E

FBConf

UDF_C136

FBConf

Integer

0,1,2,3 or special

SPI-E

Control
Narrative **
Control
Type **
ABB Service
Description

SPI Table
Name

800xA Property

Based on

Prep.

: C R Rogers

25Feb08

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

Resp. dept.

- SPI Demonstration

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

31
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

Instrument
Tag Type

Motor
On/Off

SPI
FieldName
(Configurable
name)

Intools/SPI
DatabaseFieldName
(Fixed)

Tag Number

CMPNT_NAME

Service

800xA Entry
Data Type

Entry

Responsible

N/A

String

N/A

SPI-E

UDF_C103

Description

String

Max 48 chars***

SPI-E

Instrument Type

CMPNT_FUNC_TYPE_ID

N/A

String

N/A

SPI-E

Status

CMPNT_HANDLE_ID

N/A

String

N/A

SPI-E

P&ID

DWG_ID

N/A

String

N/A

SPI-E

InteractionPar

UDF_C101

InteractionPar

ValvePar

Max 20 chars

ABB

UDF_C30

N/A

String

N/A

SPI-E

UDF_C31

N/A

String

N/A

SPI-E

UDF_C102

IO

IOPar

Max 20 chars

ABB

UDF_C104

Out

Control
Connection

Max 20 chars

SPI-E

AEClass

UDF_C108

AEClass

Integer

1-9999

SPI-E

AEConfOE

UDF_C109

AEConfOE

Integer

0-4

SPI-E

AESevOE

UDF_C110

AESevOE

Integer

1-1000

SPI-E

Control
Narrative **
Control
Type **
IOPar
SP

SPI Table
Name

800xA Property

Based on

Prep.

: C R Rogers

25Feb08

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

Resp. dept.

- SPI Demonstration

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

32
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

Instrument
Tag Type

Motor
Var Speed

SPI
FieldName
(Configurable
name)

Intools/SPI
DatabaseFieldName
(Fixed)

DeviceType

UDF_C135

FBConf

800xA Entry
Data Type

Entry

Responsible

DeviceType

Integer

1-4

SPI-E

UDF_C136

FBConf

Integer

0,1,2,3 or special

SPI-E

Tag Number

CMPNT_NAME

N/A

String

N/A

SPI-E

Service

UDF_C103

Description

String

Max 48 chars***

SPI-E

Instrument Type

CMPNT_FUNC_TYPE_ID

N/A

String

N/A

SPI-E

Status

CMPNT_HANDLE_ID

N/A

String

N/A

SPI-E

P&ID

DWG_ID

N/A

String

N/A

SPI-E

InteractionPar

UDF_C101

InteractionPar

ValvePar

Max 20 chars

ABB

UDF_C30

N/A

String

N/A

SPI-E

UDF_C31

N/A

String

N/A

SPI-E

UDF_C102

IO

IOPar

Max 20 chars

ABB

UDF_C104

Out

Control
Connection

Max 20 chars

SPI-E

Control
Narrative **
Control
Type **
IOPar
SP

SPI Table
Name

800xA Property

Based on

Prep.

: C R Rogers

25Feb08

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

Resp. dept.

- SPI Demonstration

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

33
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

Instrument
Tag Type

SPI
FieldName
(Configurable
name)

Intools/SPI
DatabaseFieldName
(Fixed)

AEClass

UDF_C108

AEConfOE

SPI Table
Name

800xA Property

800xA Entry
Data Type

Entry

Responsible

AEClass

Integer

1-9999

SPI-E

UDF_C109

AEConfOE

Integer

0-4

SPI-E

AESevOE

UDF_C110

AESevOE

Integer

1-1000

SPI-E

DeviceType

UDF_C135

DeviceType

Integer

1-4

SPI-E

FBConf

UDF_C136

FBConf

Integer

0,1,2,3 or special

SPI-E

IOPar and InteractionPar are multi-element variables used in System 800xA achieve connections of the instrument object to IO and to control
applications. These are to be defined and entered into SPI by ABB. Refer to System 800xA manuals for more information.
* SoftTag, is an optional methods of defining the instatiated 800xA object name if it is not to take Tag Number definition
** Control Narrative and Control Type are optional methods of defining specific control requirements.
*** Maximum 20 characters displayable in minimised faceplate although all 48 characters will be displayed on extended faceplate
**** Typical optional locations.

Based on

Prep.

: C R Rogers

25Feb08

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

Resp. dept.

- SPI Demonstration

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

34
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

APPENDIX B Tag Browsers and Reports


Instrument Data Reports
Instrument data reports are generated using Instrument Index browsers that have been
configured in SPI for ABB use. A set of Instrument Index Standard Browser views is
included below, based on a simple sample database. These show typical data only.

ABB Reserved Data (All)


Browser fields list:
SPI Field (Given) Name

Column
Width
50
52
20
30
20
20
10
20
20
20
20
20
20
20
20
20
20
100
100
100
100
100
100
100
100
100
40
40
40
40
40

Tag Number
Service
Status
P&ID
Maximum DCS Range
Minimum DCS Range
DCS Range Unit
Soft Tag
Low Event
High Event
Low Low Setpoint
Low Setpoint
High Setpoint
High High Setpoint
Setpoint
Control Narrative
Control Type
ABB Service Desc
InteractionPar
IOPar
Service (Faceplate)
SP
OutPar
AEClass
AEConfOE
AESevOE
AEConfLL
AEConfL
AEConfH
AEConfHH
AEFilterTime

SPI Database Field Name


CMPNT_NAME
CMPNT_SERV
CMPNT_HANDLE_ID
DWG_ID
DCS_RANGE_MAX
DCS_RANGE_MIN
DCS_RANGE_UOM
UDF_C11
UDF_C18
UDF_C19
SPI Owner Dependant
SPI Owner Dependant
SPI Owner Dependant
SPI Owner Dependant
UDF_C24
UDF_C30
UDF_C31
UDF_C36
UDF_C101
UDF_C102
UDF_C103
UDF_C104
UDF_C105
UDF_C108
UDF_C109
UDF_C110
UDF_C112
UDF_C113
UDF_C114
UDF_C115
UDF_C117

Based on

Prep.

: C R Rogers

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

- SPI Demonstration

25Feb08

Resp. dept.

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

35
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

SPI Field (Given) Name

Column
Width
40
40
40
40
40
40
40
40
40
40
40
5
5
5

AEHysterisis
AESevLL
AESevIL
AESevH
AESevHH
InNormal
OutNormal
AEConfDiff
AESevDiff
DeviceType
FBConf
P of PID Value
I of PID Value
D of PID Value

SPI Database Field Name


UDF_C118
UDF_C120
UDF_C121
UDF_C122
UDF_C123
UDF_C130
UDF_C131
UDF_C132
UDF_C133
UDF_C135
UDF_C136
UDF_C141
UDF_C142
UDF_C143

Based on

Prep.

: C R Rogers

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

- SPI Demonstration

25Feb08

Resp. dept.

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

36
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

Example browser view taken from SPI display:

Based on

Prep.

: C R Rogers

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

- SPI Demonstration

25Feb08

Resp. dept.

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

37
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

ABB Extract AI
Browser fields list:
SPI Field (Given) Name

Column
Width
50
52
20
30
10
20
20
10
20
20
20
20
20
20
20
20
20
20
100
100
100
100
100
100
40
40
40
40
40
40
40
40
40
40
5
5
5

Tag Number
Service
Status
P&ID
Instrument Type
Maximum DCS Range
Minimum DCS Range
DCS Range Unit
Soft Tag
Low Event
High Event
Low Low Setpoint
Low Setpoint
High Setpoint
High High Setpoint
Setpoint
Control Narrative
Control Type
InteractionPar / Controller Action
IOPar
OutPar / UDF_C105
AEClass / UDF_C108
AEConfOE / UDF_C109
AESevOE / UDF_C110
AEConfLL / Max ICSS Range
AEConfL / Alarm Description
AEConfH / Low Low Alm Grp
AEConfHH / Low Alm Grp
AEFilterTime / High High Alm Grp
AEHysterisis / Tel Equip List Rev
AESevLL / Max Temporary UDF
AESevIL / dBA @1W, 1m
AESevH / dBA @rating, 1m
AESevHH / Transmit Power
P of PID Value
I of PID Value
D of PID Value

SPI Database Field Name


CMPNT_NAME
CMPNT_SERV
CMPNT_HANDLE_ID
DWG_ID
CMPNT_FUNC_TYPE_ID
DCS_RANGE_MAX
DCS_RANGE_MIN
DCS_RANGE_UOM
UDF_C11
UDF_C18
UDF_C19
SPI Owner Dependant
SPI Owner Dependant
SPI Owner Dependant
SPI Owner Dependant
UDF_C24
UDF_C30
UDF_C31
UDF_C101
UDF_C102
UDF_C105
UDF_C108
UDF_C109
UDF_C110
UDF_C112
UDF_C113
UDF_C114
UDF_C115
UDF_C117
UDF_C118
UDF_C120
UDF_C121
UDF_C122
UDF_C123
UDF_N01
UDF_N02
UDF_N03

Based on

Prep.

: C R Rogers

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

- SPI Demonstration

25Feb08

Resp. dept.

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

38
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

Browser filter settings: None

Example browser view taken from SPI display:


Part 1

Based on

Prep.

: C R Rogers

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

- SPI Demonstration

25Feb08

Resp. dept.

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

39
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

Part 2

Based on

Prep.

: C R Rogers

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

- SPI Demonstration

25Feb08

Resp. dept.

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

40
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

ABB Extract - DI
Browser fields list:
SPI Field (Given) Name

Column
Width
50
52
20
10
30
20
20
20
100
100
100
100
100
40
40
40

Tag Number
Service
Status
Instrument Type
P&ID
Soft Tag
Control Narrative
Control Type
InteractionPar / Controller Action
IOPar / UDF_C102
AEClass / UDF_C108
AEConfOE / UDF_C109
AESevOE / UDF_C110
InNormal / Housing Manufact
AEConfDiff / Camera Manufact
AESevDiff / Camera Model No

SPI Database Field Name


CMPNT_NAME
CMPNT_SERV
CMPNT_HANDLE_ID
CMPNT_FUNC_TYPE_ID
DWG_ID
UDF_C11
UDF_C30
UDF_C31
UDF_C101
UDF_C102
UDF_C108
UDF_C109
UDF_C110
UDF_C130
UDF_C132
UDF_C133

Based on

Prep.

: C R Rogers

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

- SPI Demonstration

25Feb08

Resp. dept.

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

41
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

Browser filter settings:

Based on

Prep.

: C R Rogers

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

- SPI Demonstration

25Feb08

Resp. dept.

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

42
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

Example browser view taken from SPI display:

Based on

Prep.

: C R Rogers

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

- SPI Demonstration

25Feb08

Resp. dept.

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

43
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

ABB Extract - DO
Browser fields list:
SPI Field (Given) Name

Column
Width
50
52
20
10
30
20
20
20
100
100
100
100
100
40

Tag Number
Service
Status
Instrument Type
P&ID
Soft Tag
Control Narrative
Control Type
InteractionPar / Controller Action
IOPar / UDF_C102
AEClass / UDF_C108
AEConfOE / UDF_C109
AESevOE / UDF_C110
OutNormal / Housing Part No

SPI Database Field Name


CMPNT_NAME
CMPNT_SERV
CMPNT_HANDLE_ID
CMPNT_FUNC_TYPE_ID
DWG_ID
UDF_C11
UDF_C30
UDF_C31
UDF_C101
UDF_C102
UDF_C108
UDF_C109
UDF_C110
UDF_C131

Based on

Prep.

: C R Rogers

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

- SPI Demonstration

25Feb08

Resp. dept.

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

44
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

Browser filter settings:

Based on

Prep.

: C R Rogers

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

- SPI Demonstration

25Feb08

Resp. dept.

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

45
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

Example browser view taken from SPI display:

Based on

Prep.

: C R Rogers

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

- SPI Demonstration

25Feb08

Resp. dept.

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

46
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

ABB Extract Valve


Browser fields list:
SPI Field (Given) Name

Column
Width
50
52
20
10
30
20
20
20
20
100
100
100
100
100
100
40
40

Tag Number
Service
Status
Instrument Type
P&ID
Soft Tag
Setpoint
Control Narrative
Control Type
InteractionPar / Controller Action
IOPar / UDF_C102
SP / UDF_C104
AEClass / UDF_C108
AEConfOE / UDF_C109
AESevOE / UDF_C110
DeviceType / Pan/Tilt Model No
FBConf / Telem Unit Manufac

SPI Database Field Name


CMPNT_NAME
CMPNT_SERV
CMPNT_HANDLE_ID
CMPNT_FUNC_TYPE_ID
DWG_ID
UDF_C11
UDF_C24
UDF_C30
UDF_C31
UDF_C101
UDF_C102
UDF_C104
UDF_C108
UDF_C109
UDF_C110
UDF_C135
UDF_C136

Based on

Prep.

: C R Rogers

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

- SPI Demonstration

25Feb08

Resp. dept.

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

47
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

Browser filter settings:

Based on

Prep.

: C R Rogers

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

- SPI Demonstration

25Feb08

Resp. dept.

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

48
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

Example browser view taken from SPI display:

Based on

Prep.

: C R Rogers

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

- SPI Demonstration

25Feb08

Resp. dept.

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

49
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

APPENDIX C Control Type Parameters Listings


Some projects may have specific functionality defined for each Control Type I a project
specific document. This Appendix provides some typical examples of the type of data that
may exist.
Control Type CTL_01
Description
Duty/Standby Valve
Control Block

Definition Document

Based on SPI Browser for


IO Type
Analogue Input

SPI FieldName
(Configurable name)
Tag Number or Soft Tag
Service
Control Narrative
Control Type
Control Setpoint
AESevOE
AEClass
HOLD 4
HOLD 4

Function Block Parameter

Name
Description
N/A
FB_PC_CTL_03 Function Block
pSP
pAESevOE
pAEClass
pDirect (DIR/REV control)
pController_Type (PID/PI/P control)

Control Type CTL_02


Description
ESD Valve

Definition Document

Based on SPI Browser for


IO Type
Valve

SPI FieldName
(Configurable name)
Tag Number or Soft Tag
Service
Control Narrative
Control Type

Function Block Parameter

Name
Description
N/A
N/A

Based on

Prep.

: C R Rogers

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

- SPI Demonstration

25Feb08

Resp. dept.

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

50
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

Control Type CTL_03


Description
ON/OFF Valve
Pneumatic

Definition Document

Based on SPI Browser for


IO Type
Valve

SPI FieldName
(Configurable name)
Tag Number or Soft Tag
Service
Control Narrative
Control Type
AEClass
AESevOE
FBConf

Function Block Parameter

Name
Desciption
N/A
N/A
pAEClass
pAESevOE
pFBConf

Control Type CTL_04


Description
Shut Down Valve

Definition Document

Based on SPI Browser for


IO Type
Valve

SPI FieldName
(Configurable name)
Tag Number or Soft Tag
Service
Control Narrative
Control Type

Function Block Parameter

DESC
DOS_TAGNAME
N/A
N/A

Control Type CTL_05


Description
ESD Isolation Valve

Document Ref.

Based on SPI Browser for


IO Type
Valve

SPI FieldName
(Configurable name)
Tag Number or Soft Tag
Service
Control Narrative
Control Type

Function Block Parameter

Name
Desciption
N/A
N/A

Based on

Prep.

: C R Rogers

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

- SPI Demonstration

25Feb08

Resp. dept.

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

51
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

APPENDIX D Panel and Wiring Reports


ABB IO Count by ICSS Area

Based on

Prep.

: C R Rogers

25Feb08

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

Resp. dept.

- SPI Demonstration

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

52
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

Cable Connection Report by Panel

Based on

Prep.

: C R Rogers

25Feb08

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

Resp. dept.

- SPI Demonstration

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

53
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

Wiring Schedules by Panel and Signal Type

Based on

Prep.

: C R Rogers

25Feb08

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

Resp. dept.

- SPI Demonstration

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

54
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

Control System Report by ICSS Area

Based on

Prep.

: C R Rogers

25Feb08

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

Resp. dept.

- SPI Demonstration

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

55
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

APPENDIX E IO Hardware Types


ABB S800 IO module terminal strips are available from the Intergraph web site on subscription
basis. Any other forms of IO will be defined as required.

Based on

Prep.

: C R Rogers

25Feb08

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

Resp. dept.

- SPI Demonstration

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

56
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

APPENDIX F Simple Process Flow Diagram


This procedure and the responsibilities will be agreed for each project. The
procedure includes all aspects of control and safety systems, as required.

ICSS
Objects

Extract Object
Tag and Data
Including A&E

Create Tagged Objects in 800xA

Objects
Definition

Non-SPI
Function

Confign
Freeze Point

Hardware Freeze and


Reference Point
plus Formal Archive
Initial Data
Archive Point
Other archives
as required

Extract Wiring
Data
Reference
Explorer
Equipment
Build

Create
Specific
System
Panels

Attach Field
Cables to
Terminals

Add Panel
Interface
Items

Add IO
Modules &
IO Termns

Configure
Cross Wiring

Panel Build
Extract Panel
Layout Info

Isolators,
terminals etc.

SPI Based
Definition data

Feedback to
appropriate design
Functions

Reference Data
IO Modules, Cable Schedule,
IO count etc.

Allocate Tags
to IO

Create Field
Cables

Based on

Prep.

: C R Rogers

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

- SPI Demonstration

Resp. dept.

: O110

Document identity

ABB Limited

Loop Diagrams

25Feb08

3BGB000225

Identification of
PCS Change
Impacts

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

57
60

Subsequent
SPI Changes
under PQ
control

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

Workflow Process Details


ICSS Objects

SPI-E develop SPI database


ABB take initial extract of SPI object data using appropriate browsers
ABB archive browser reports
ABB relate object data with Definition Document requirements (Point A)
ABB configure objects on 800xA
At agreed time, establish software freeze
o SPI-E hold on SPI changes
o ABB take extract of SPI object data and archive browser reports
o SPI-E released to continue SPI update
Procedure continues from Point A above

PSD/F&G/ESD Objects

SPI-E develop SPI database


ABB take initial extract of SPI object data using appropriate browsers
o ABB archive browser reports
ABB relate object data with Definition Document requirements (Point A)
ABB relate object data with A&E data
ABB configure PSD/F&G/ESD objects

Based on

Prep.

: C R Rogers

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

- SPI Demonstration

25Feb08

Resp. dept.

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

58
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

At agreed time, establish software freeze


o SPI-E hold on SPI changes
o ABB take extract of SPI object data and archive browser reports
o SPI-E released to continue SPI update
Procedure continues from Point A above

Based on

Prep.

: C R Rogers

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

- SPI Demonstration

25Feb08

Resp. dept.

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

59
60

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB

ICSS Panels, Cables and Panel Wiring


SPI-E develop SPI IO database and cable schedule
ABB build standardised equipment in SPI Reference Explorer
ABB create specific ICSS panels in SPI based on SPI reference data
SPI-E create field single and multicore cables
ABB add equipment terminal strips for field cables
ABB connect field cables to equipment terminals
ABB add IO module and IO terminations
SPI-E allocate tags to IO channels
ABB add panel signal interface components
ABB configure cross wiring
Loop diagrams available for production
Establish hardware design freeze
ABB extract wiring data and panel layout information for panel build
ABB continue from the appropriate earlier point in this list
Remote IO Panels, Cables and Panel Wiring
These panels are a standardised build with pre-fitted terminals that accept single pair field cables.
SPI-E connect single pair field cables to terminals
ABB add panel signal interface components
SPI-E allocate tags to IO channels
ABB configure the cross wiring

Based on

Prep.

: C R Rogers

Appr.

: D J Dobson

25Feb08

Doc. kind

Procedure

Doc.

Item

des.

des.

Title

Project

Typical Project Procedure for use of SPI


with System 800xA

- SPI Demonstration

25Feb08

Resp. dept.

: O110

Document identity

ABB Limited

3BGB000225

Lang.

en

Rev. ind. Sheet

1.0

No. of sh.

60
60