Sei sulla pagina 1di 4

Code

Description

C0001

LCT Communication Failure


- Due to a software malfunction, etc., the time on the watchdog timer has run out
and a reset is performed.

C0202

Tray 1 Elevator Failure


- The Lift-Up Sensor is not unblocked even after the set period of time has elapsed
after the paper lift up operation for the drawer has begun.

C0204

Tray 2 Elevator Failure


- The Lift-Up Sensor is not unblocked even after the set period of time has elapsed
after the paper lift up operation for the drawer has begun.

C0206

Tray 3 Elevator Failure


- The Lift-Up Sensor is not unblocked even after the set period of time has elapsed
after the paper lift up operation for the drawer has begun.

C0208

Tray 4 Elevator Failure


- The Lift-Up Sensor is not unblocked even after the set period of time has elapsed
after the paper lift up operation for the drawer has begun.

C0209

LCT Elevator Motor Failure


- The Elevator Motor Pulse Sensor (PC10-LCT) cannot detect both edges of H/L
even after the set period of time has elapsed while the Elevator Motor (M5-LCT)
is turning backward/forward (raise/lower).

C0211

Bypass Lifting Motion Failure


- The Bypass Lift Sensor (PC29) is not blocked or unblocked even after the set
period of time has elapsed after the Bypass Pick-Up Solenoid (SL3) is energized
after the manual feed paper take-up operation has begun.

C0212

LCT Ejection Failure


- See PC-407 sevice manual

C0213

LCT Shift Gate Malfunction


- See PC-407 sevice manual

C0214

LCT Shifting Failure


- See PC-407 sevice manual

C0215

LCT Shift Motor Malfunction


- See PC-407 sevice manual

C0701

Manual Paper Size Detection Adjustment Failure


- The control value of the Manual Paper Size Detection Unit does not fall within
the specified range when an adjustment is made of manual paper size detection.

C1080

Exit Option Communication Failure


- The connection status of a finishing option is changed after the copier has been
turned on.

C1183

Elevator Motor Ascent/Descent Drive Failure


- See FS-530/ PU-501/ OT-602 service manual.

C1190

Aligning Plate 1 Drive Failure


- See FS-530/ PU-501/ OT-602 service manual.

C1191

Aligning Plate 2 Drive Failure


- See FS-530/ PU-501/ OT-602 service manual.

C11A0

Paper-Lifter Drive Failure

C11A1

Exit Roller Pressure/Retraction Failure

- See FS-530/ PU-501/ OT-602 service manual.


C11A2

Saddle Exit Roller Pressure/ Retraction Failure


-See SD-507 service manual.

C11A3

Shutter Drive Failure


- See FS-530/PU-501/OT-602 service manual.

C11A4

Saddle Exit Motor Failure


- See SD-507 service manual.

C11A5

Saddle In & Out Guide Motor Failure


- - See SD-507 service manual.

C11A6

Saddle Layable Guide Motor Drive Failure


- See SD-507 service manual.

C11B0

Staple Unit CD Drive Failure


- See FS-530/PU-501/OT-602 service manual.

C11B2

Staple Drive Failure


- See FS-530/PU-501/OT-602 service manual.

C11B5

Saddle Staple 1 Drive Failure


- See SD-507 service manual.

C11B6

Saddle Staple 2 Drive Failure


- See SD-507 service manual.

C11C0

Punch Cam Motor Unit Failure


- See FS-530/PU-501/OT-602 service manual.

C11D0

Crease Motor Drive Failure


- See SD-507 service manual.

C2211

IU Motor Failure
- The IU Motor Lock signal remains set to H for a set period of time while the IU
Motor is turning.
- The IU Motor Lock signal remains set to L for a set period of time while the IU
Motor remains stopped.

C2351

Toner Suction Fan Motor Failure


- The Toner Suction Fan Motor Lock signal remains set to H for a set period of
time while the Toner Suction Fan Motor is turning.
- The Toner Suction Fan Motor Lock signal remains set to L for a set period of
time while the Toner Suction Fan Motor remains stopped.

C2431

IU Fuse Blowing Failure


- The fuse is not blown even after the lapse of a predetermined period of time.

C2557

ATDC Sensor Failure


- The scanning value of the ATDC Sensor is less than 7 % while the IU Motor is
turning.
- The scanning value of the ATDC Sensor is more than 19 % while the IU Motor is
turning.

C255C

ATDC Adjustment Failure


- The adjustment of the ATDC control voltage could not be completed in the set
period of time when function F8 is run.
- The ATDC control voltage was not within the range of 5.39 V to 8.15 V when
function F8 is run.

C2654

EEPROM Failure

- An EEPROM where no initial data is written is detected


C2702

Abnormal Image Transfer Voltage


- The image transfer voltage exceeds 100 V for the set period of time while the IU
Motor remains stopped.

C3451

Fusing Warm-Up Failure (Main)


- The Fusing Roller Thermistor does not detect the required temperature within 30
sec. after a warmup cycle has begun; therefore, the copier does not complete the
warm-up cycle.
- The temperature of the Fusing Rollers does not reach the required level even
after the set period of time has elapsed during a warm-up cycle.

C3452

Fusing Warm-Up Failure (Sub)


- The Fusing Roller Sub Thermistor does not detect the required temperature
within 30 sec. after a warm-up cycle has begun; therefore, the copier does not
complete the warm-up cycle.
- The temperature of the Fusing Rollers does not reach the required level even
after the set period of time has elapsed during a warm-up cycle.

C3751

High Fuser Temperature Failure (Main)


- The Fusing Roller Thermistor and Fusing Roller Sub Thermistor are detected to
be at a temperature above 240 C when the Main Power Switch is set to ON.

C3752

High Fuser Temperature Failure (Sub)


- The Fusing Roller Thermistor and Fusing Roller Sub Thermistor are detected to
be at a temperature above 240 C when the Main Power Switch is set to ON.

C3851

Low Fuser Temperature Failure (Main)


- The Fusing Roller Thermistor and Fusing Roller Sub Thermistor are detected to
be at a temperature below 105 C during standby.
- The Fusing Roller Thermistor and Fusing Roller Sub Thermistor are detected to
be at a temperature below 105 C during printing.

C3852

Low Fuser Temperature Failure (Sub)


- The Fusing Roller Thermistor and Fusing Roller Sub Thermistor are detected to
be at a temperature below 105 C during standby.
- The Fusing Roller Thermistor and Fusing Roller Sub Thermistor are detected to
be at a temperature below 105 C during printing.

C4001

Main body Communication Failure


Communications with the Mechanical Control Board and the MFBS
Board/MFBS2 Board fail.

C4002

HSYNC Detection Failure


- No SOS falling edges are detected within the set period of time after laser
emission began while the Polygon Motor is turning.
- No SOS falling edges are detected while VIA remains ON.

C4101

Polygon Motor Failure


- The Polygon Motor Lock signal could not be detected within the set period of
time after the Polygon Motor is energized. (Faulty start detection)
- No First Lock signals are detected during the 1- second period that starts 1
second after a First Lock signal. (Faulty lock signal detection)
- The Polygon Motor Lock signal could not be detected after the set period of time
has elapsed while the Polygon Motor is turning. (Out-of-timing lock detection)
- The Polygon Motor Lock signal is set to ON for longer than the set period of
time while the Polygon Motor remains stopped. (Abnormal lock detection)

C4721

Main Body G/A Communication Failure


- Communications with the gate array for expansion I/O (the IC mounted on the
Mechanical Control Board) fail.

C5102

Main Motor Failure


- The Transport Motor Lock signal remains set to H for a set period of time while
the Transport Motor is turning.

C5351

Power Supply Cooling Fan Motor Failure


- The Power Supply Cooling Fan Motor Lock signal remains set to H for a set
period of time while the Power Supply Cooling Fan Motor is turning.
- The Power Supply Cooling Fan Motor Lock signal remains set to L for a set
period of time while the Power Supply Cooling Fan Motor remains stopped.

C5352

Cooling Fan Motor Failure


- The Cooling Fan Motor Lock signal remains set to H for a set period of time
while the Cooling Fan Motor is turning.
- The Cooling Fan Motor Lock signal remains set to L for a set period of time
while the Cooling Fan Motor remains stopped

C5353

IU Cooling Fan Motor Failure


- The IU Cooling Fan Motor Lock signal remains set to H for a set period of time
while the IU Cooling Fan Motor is turning.
- The IU Cooling Fan Motor Lock signal remains set to L for a set period of time
while the IU Cooling Fan Motor remains stopped.

C7001

Engine connection error


- The system fails in checking initial engine connection when the Power Switch is
turned ON.
- The system succeeded in checking initial connection when the Power Switch
was turned ON; then it fails in rechecking initial connection through the execution
of a software reset when a communications error occurs during operation.

C8301

ADF Fan Motor Failure


- See DF-620 service manual.

C9701

ADF Document Size Failure Adjustment


- See DF-620 service manual.

CA052

MIO Device Failure


- The MIO device does not operate properly

CC153

Flash ROM Failure


- The Flash ROM data was determined to be faulty when the unit was turned on.

CC155

Exit Option Flash ROM Failure


- See FS-530/PU-501/OT-602 service manual.

CD004

HDD error
- When error occurs during deletion of HDD data.

Potrebbero piacerti anche