Sei sulla pagina 1di 16

www.lgeaircon.

com

© LG Electronics Inc. Printed in Korea 2011


For continual product development, LG reserves the right to change specifications without notice.
LG Electronics Air Conditioning & Energy Solution
20 Yoido-dong, Youngdungpo-gu,
Yoido P.O.Box 355 Seoul 150-721, Korea
Phone: 82-2-3777-7613

http://www.lgeaircon.com

IDEAL HEATING AND COOLING UNITS


Catalogue 2011

Specifications, design and feature in this catalogue are subject to change without prior notice. EU-CA110

2011_Therma_V_Final_Tomi.indd 1-1 2011.05.06. 12:38:42


LG Electronics’
Eco-friendly Technology
LG Electronics’ environmental policy is centered on its “Life’s Good
When it’s Green” program. The program is divided into two areas: Nature.....
pre-production and post-production. LG Electronics’ goal is to
reduce greenhouse gases in the pre- and post-production stages
Human.....
by 150,000 tons and 30,000,000 tons, respectively, by 2020. This
reduction of greenhouse gases emitted during a product’s life cycle
(including raw materials used in production, product distribution, Comfort.....
product usage, and product disposal) will be carried out in stages.

THERMA V LINE UP 04
WHAT IS THERMA V? 06
-The Solution for New Housing and Renovation

BENEFITS OF THERMA V 08
- Energy Performance
- Respecting the Environment
- Convenient Control
- Anti-Corrosion Gold Fin™
- Easy Installation
- Constant Heating - V2 Injection

THERMA V SPLIT _ INDOOR UNIT: HYDRO KIT (1Ø, 3Ø) 14


THERMA V SPLIT _ OUTDOOR UNIT (1Ø 230V) 16
THERMA V SPLIT _ OUTDOOR UNIT (3Ø 400V) 18
THERMA V V2 INJECTION 20
THERMA V MONO _ OUTDOOR UNIT (1Ø 230V) 22
THERMA V MONO _ OUTDOOR UNIT (3Ø 400V) 24
THERMA V INDOOR BOX FOR 3Ø MONO 26
THERMA V SANITARY WATER TANK 28
FLEXIBLE APPLICATION 30

2011_Therma_V_Final_Tomi.indd 2-3 2011.05.06. 12:38:44


LINE-UP LG Innovation Ideal Heating and Cooling Unit
THERMA V Split Type (R410A) _ 1Ø 230V / 3Ø 400V THERMA V, Ideal Heating and Cooling Unit, Aiming at all-in-one Solution
Capacity _ kW 9.0 12.0 14.0 16.0
Economical : According to its innovative technology and advanced performance efficiency,
THERMA V offers one of the most cost-efficient and payback with any heating and cooling system in
the market!

Flexible : A solution that is easy to install and does not require house renovations.
Split
(R410A)
Natural : THERMA V respects the environment by using two renewable energy resources; air and
sun, by reducing CO2 emissions.

1ø 1ø / 3ø 1ø / 3ø 1ø / 3ø
Government Subsidy : According to recent trends, the adoption of renewable energy, the heat
pumps may enable consumers to obtain a government subisidy under certain conditions.
THERMA V Split V2 Injection Type (R410A) _ 1Ø 230V / 3Ø 400V
Capacity _ kW 12.0 14.0

Split
V2 Injection
(R410A)

1ø / 3ø 1ø / 3ø
* Split V2 Injection available from August in the market

THERMA V MONO Type (R407C) _ 1Ø 230V / 3Ø 400V


Capacity _ kW 10.0 12.0 14.0

MONO
(R407C)

1ø / 3ø

SANITARY TANK
Volume_Liter Single Coil, 200 liter Single Coil, 300 liter Double Coil, 200 liter Double Coil, 300 liter

Sanitary
Water Tank

2011_Therma_V_Final_Tomi.indd 4-5 2011.05.06. 12:38:55


What is THERMA V?
A Natural Solution
›<Zfefd`ZXcjpjk\dn`k_X[mXeZ\[:f\]]`Z`\ekf]G\i]fidXeZ\1:FG4+%,
›Lk`c`qXk`fef]knfi\e\nXYc\\e\i^`\j18`iXe[jle%
›I\[lZ\[:F2 emissions compared to gas or fuel heating.
The Solution for New Buildings and Renovation
A Flexible Solution
THERMA V is specially conceived to respond to the needs of the renovation market (to relieve or replace a boiler) and
the new construction market. The product adapts perfectly to individual and collective residential applications. ›DfefmXc\ekfg\iXk`fe1
Moreover, this Air-to-Water heat pump makes up an eco-friendly product that uses two renewable energy resources – THERMA V is capable of responding to all of your daily comfort & energy needs.
air and sun. Finally, it proves economics with Coefficient of Performance (COP) up to 4.5, among the most advanced
technologies on the market.
In addition, if the outdoor temperature decreases below the seasonal temperature, a backup electric heater
will come to guarantee your optimal well-being.

Application : Replacing Coventional Boiler


THERMA V
Hydro Kit œKHDAL Backup Electric
Heater
Refrigerant Water
Hydro Kit Fan Coil Unit
Sanitary
Radiator
Water Tank Reversible
Heat Pump Radiator
Option : Underfloor Heating
Sanitary Water Tank

œEGFG:DG; Backup Electric


Heater
Water
Solar Panel
Fan Coil Unit
Reversible Radiator
Heat Pump Underfloor Heating
Option : Sanitary Water Tank

›8ck\ieXk`m\9`mXc\ekFg\iXk`fe1
THERMA V heat pump can also be integrated in the installation of existing boiler(gas or fuel).
Boiler takes over space heating and sanitary hot water, in case of severe low ambient temperature.
Room thermostat
Application : Using Existing Boiler

œKHDAL Backup Electric


Heater
Refrigerant Water
Hydro Kit Fan Coil Unit

Underfloor THERMA V Radiator


Reversible Boiler
Heating Outdoor Unit Underfloor Heating
Heat Pump
Option :
Sanitary Water Tank

›Different heat transmitters : ›Optional Accessories :


> Underfloor Heating > Sanitary Water Tank œEGFG:DG;
> Radiators Water
(Low Temperature Radiators) Fan Coil Unit
Reversible Radiator
> Fan Coil Units Heat Pump Boiler
Underfloor Heating
Option : Sanitary Water Tank

LG Air Conditioners 2011 06 / 07

2011_Therma_V_Final_Tomi.indd 6-7 2011.05.06. 12:39:00


:]f]^alkg^THERMA V

Energy Performance Respecting the Environment


Advanced Coefficient of Performance (COP) for More Energy Saving Reducing CO2 Emissions
As generating energy from outdoor air even in low The THERMA V solution by LG adopts two renewable energies, air and sun.

COP
temperature, THERMA V makes it possible to heat efficiently. 4.49
This eco-friendly system will decrease CO2 emissions from heating systems on fossil energies such as
With inverter technology of LG, THERMA V can make higher 4.44 gas and fuel.
efficiency level up to the range of 4.1 to 4.5. 4.20
4.09
In other words, consuming 1kW of electric energy of an
ANNUAL CO2 EMISSION
electrical network enables more than 4kW of heating energy.
(kg / year)
4,563kg
0,8~0,9

Other Heating Systems


38%
(Electrical Convector/Boiler)
2,839kg

Fuel/Gas Boiler
CO2 NO Gas Boiler
THERMA V Heating Fuel/Gas Boiler
Outdoor Air
Heat Pump Hot Water Solar Panels THERMA V Source : Eurelectric

Fuel/Gas
75% of
Free Energy 100% 90%
Electrical Convector
100%
25%

100% 100%

Other Heating Systems (Electrical Convector/Boiler)

Inverter regulation, for more serenity


Once the desired temperature is achieved, unlike conventional air to water heat pump that turns the compressor on
and off, LG inverter units adjust and constantly vary the compressor speed to maintain the desired temperature with
minimal fluctuation to ensure your comfort.

LG Air Conditioners 2011 08 / 09

2011_Therma_V_Final_Tomi.indd 8-9 2011.05.06. 12:39:05


:]f]^alkg^THERMA V

Convenient Control Easy Installation


›:fekifc_\Xk`e^Xe[jXe`kXip_fknXk\i
- Weekly scheduling Indoor Unit
- Operating modes
- Water temperature
Hydro Kit
- Heating emergency operation
Separated Shut-off valves

Afl]_jYl]\
Grips

THERMA V THERMA V Sanitary Hot Water


Outdoor Unit Indoor Unit Tank
Hydro Kit

Heating Emergency Operation


Heating is essential during winter. THERMA V is equipped
with an emergency operation that allows the maintenance Outdoor Unit
of heating in case of possible failure.
The heating security mode consist of two levels: Facilitated maintenance
›C\m\c(1N_\ek_\`e[ffile`kjc`^_kcpdXc]leZk`fej#k_\ - Refrigerating connection is possible in three directions - Access to vital parts of the unit thanks to the new remo-
vable front panel fixed with three screws.
outdoor unit operates under a pre-defined emergency
operation mode.

›C\m\c)1N_\eflk[ffile`kdXc]leZk`fej#\c\Zkife`Z
heater of the indoor unit operates under a pre-defined
emergency operation mode.

1 Direction 3 Direction
Anti-Corrosion Gold Fin™
Jacking-up Grips
- Easy to carry thanks to the integrated grips
The exchangers of our outdoor unit are treated against corrosion and pollution. This treatment guarantees the
durability of the systems and high-level performance.

> Salt Spray Test for 15 Days

LG Gold Fin™ Easy access to 3 fixation


Uncoated compressor screws
Protected Alumium
Alumium

After 15 days After 15 days

LG Gold Fin™ Conventional


Corrosion Starting to
Resistance Corrode

LG Air Conditioners 2011 10 / 11

2011_Therma_V_Final_Tomi.indd 10-11 2011.05.06. 12:39:12


:]f]^alkg^THERMA V
V2 Injection technology adopted by THERMA V Split offers you most comfortable
atmosphere in extreme cold weather condition by providing 100% heating performance
at -15ºC without an auxiliary heater or boiler. Therefore, it saves users electricity cost
greatly (Peak data result with heating steady-state without defrost effect at the test condition of A*/W35)
Split V2 Injection : Logic - Functioning
Heating capacity Increase - V2 Injection Rotary compressor
100% performance at -15ºC without electric heaters
Cycle Diagram

100% stable & constant heating down to -15ºC


A Compelling (THERMA V provides 100% comfort at any condition Water
Inlet
Reason to Use even down to -15ºC without an auxiliary heater)
D?N*Afb][lagf Heat
exchanger
75% heating performance at -20ºC EEV2

EEV3 EEV1
Save electricity Afn]jl]jl][`fgdg_q
consumption Eco-friendly offers
and reduce electricity bill ultimate comfortable
2 Stage
environment
Rotary Comp.

Water
Outlet
Phase Separator

Constant Heating - V2 Injection Technology


Effects of V2 Injection technology
LG conducted a real field test in Norway
Expansion of THERMA V operating range Heating capacity increase
to secure reliability at severe low temperatures.

LG V2 Injection (14kW)
100%

75%

50%
-20 °C -15 °C -5 °C 5 °C 10 °C

Normal AWHP LG
Outdoor Temperature Heating Capacity @A-15 / W35

LG Air Conditioners 2011 12 / 13

2011_Therma_V_Final_Tomi.indd 12-13 2011.05.06. 12:39:24


Hydro Kit (1ø, 3ø)

THERMA V
KHDAL
Af\ggjMfal INDOOR UNITS
HYDRO KIT
Hydro Kit HN0916. NK1

HN0926. NK1
Up to 9kW
HN0936. NK1

HN0914. NK1

HN1616. NK1

HN1626. NK1

HN1636. NK1 Up to 16kW

HN1629. NK1

Specifications HN1639. NK1

Hydro Kit _ Indoor Unit *HN0916. *HN0926. *HN0936. HN0914. HN1616. HN1626. HN1636. *HN1629. HN1639. 474 305
NK1 NK1 NK1 NK1 NK1 NK1 NK1 NK1 NK1
490 313.2 13
Combined Outdoor Unit
HU121.U31 - 1ø 230V HUV121.U31 - 1ø 230V 8
14

9
HU141.U31 - 1ø 230V HUV141.U31 - 1ø 230V
HU161.U31 - 1ø 230V HUV141.U31 - 1ø 230V 8’
10
15
HU091.U41 - 1ø 230V
HU123.U31 - 3ø 400V HUV123.U31 - 3ø 400V

850
7
HU143.U31 - 3ø 400V HUV143.U31 - 3ø 400V

848
18
HU163.U31 - 3ø 400V HU121.U31 - 1ø 230V 11

12

Electric Heater Power Supply ø/V/Hz 1ø/220-240V/50Hz 3ø/220V/50Hz 3ø/380-415V/50Hz 1ø/220-240V/50Hz 1ø/220~240V/50Hz 3ø/220V/50Hz 3ø/380-415V/50Hz 3ø/220V/50Hz 3ø/380-415V/50Hz 6

Heater Capacity kW 6 4 6 9 5

Dimension W*H*D mm 490*850*313 490*850*313


Weight kg 52 55
Noise Level at 1 meter dB(A) 28 28
Leaving Water Heating ºC 15~55 15~55 1 2 17 3 17 4
Temperature
Cooling ºC 6~30 6~30
Water Pump Max. Power Input Watt 135 205 N° ITEM N° ITEM
Minimum Water LPM 1 Refrigerating Pipe - Gas 10 Flow Switch
Flow Rate 15 15
2 Refrigerating Pipe - Liquid 11 Plate Heat Exchanger

Max. Head meter 6.4 7 3 Water Connection – Entry – 1 inch 12 Pressure Gage

Expansion Tank liter 8 8 4 Water Connection – Exit – 1 inch 13 Expansion Tank

5 Controller 14 Air-vent
* Available from June of 2011
6 Water Pump 15 Electric Heater

7 Discharge Gate – Open when pressed > 3 bars 16 Strainer


8 Thermal switch 17 Shut-off Valve

8’ Thermal switch 18 Carrying handle


9 Control Box

Separated Shut-off valves

LG Air Conditioners 2011 14 / 15

2011_Therma_V_Final_Tomi.indd 14-15 2011.05.06. 12:39:29


Outdoor Unit (1ø 230V)
Maximum 55ºC Leaving Water Temperature

THERMA V
OUTDOOR UNIT
KHDALW)¬ HU091. U41 9kW

N° ITEM

1 Liquid side service valve(mm)

834
48 56 4817 88
56 48 2 Gas side service valve(mm)

364

61

81565231
3 Air discharge grill
Specifications

158

150
81 68
24

24
74 4 Control Cover
93 27 80 42
165 620 165 390

Outdoor Unit HU091. U41 HU121. U31 HU141. U31 HU161. U31 165 620 165

Combined Indoor Unit

30
Hydro Kit

392
358
330
HN1616. NK1
HN0916. NK1
HN1626. NK1 4 Holes for anchor bolts
HN0926. NK1
HN1636. NK1
HN0936. NK1
HN1629. NK1
HN0914. NK1
HN1639. NK1
OUTDOOR UNIT
HU121. U31 12kW
Power Supply ø/ V / Hz 1ø / 220-240V / 50Hz
HU141. U31 14kW
Nominal Heating(A10/W35) kW 9.71 13.32 14.94 16.93
Capacity
Heating(A7/W35) kW 9 12 14 16 HU161. U31 16kW
Heating(A2/W35) kW 6.87 9.4 10.69 11.9
Heating(A-7/W35) kW 8.61 11.48 13.11 14.8
Cooling(A35/W18) kW 9.00 14.00 14.00 14.00
Nominal Input Heating(A10/W35) kW 2.2 2.99 3.39 3.87
Supporter
Heating(A7/W35) kW 2.2 2.67 3.15 3.81
Heating(A2/W35) kW 2.07 2.8 3.22 3.62
Heating(A-7/W35) kW 3.19 4.16 4.85 5.61
Cooling(A35/W18) kW 2.65 4.40 4.40 4.40

1380
COP Heating(A10/W35) W/W 4.41 4.45 4.41 4.37
N° ITEM
Heating(A7/W35) W/W 4.09 4.49 4.44 4.20
1 Liquid side service valve(mm)
Heating(A2/W35) W/W 3.32 3.36 3.32 3.29
2 Gas side service valve(mm)

490
56 48 56 48
Heating(A-7/W35) W/W 2.70 2.76 2.70 2.64
3 Air discharge grill

74 52 31
EER Cooling(A35/W18) W/W 3.40 3.18 3.18 3.18

23 134
20 115
138

150
18 68
4 Control Cover

18
24
26
93 73 72 80 80 42
Sound Heating dBA 52 53 950 390

pressure level
Cooling dBA 52 54
165 620 165

Dimension W*H*D mm 950*834*330 950*1,380*330

30
Weight kg 64 105

404
361
330
Refrigerant Pre-charged amount g 1,900 2,980
(R410A) 4 Holes for anchor bolts
Pipe Diameter(Liquid/Gas) inch 3/8, 5/8

LG Air Conditioners 2011 16 / 17

2011_Therma_V_Final_Tomi.indd 16-17 2011.05.06. 12:39:33


Outdoor Unit (3ø 400V)
Maximum 55ºC Leaving Water Temperature

THERMA V
OUTDOOR UNIT
KHDALW+¬ HU123. U31 12kW

HU143. U31 14kW

HU163. U31 16kW

Supporter

Specifications
Outdoor Unit HU123. U31 HU143. U31 HU163. U31

1380
Combined Indoor Unit
Hydro Kit

HN1616. NK1
HN1626. NK1

490
HN1636. NK1 56 48 56 48

HN1629. NK1

74 52 31
HN1639. NK1

23 134
20 115
138

150
18 68

18
24
26
93 73 72 80 80 42
950 390

Power Supply ø/ V / Hz 3ø / 380-415V / 50Hz


165 620 165
Nominal Heating(A10/W35) kW 13.25 15.06 17.34

30
Capacity
Heating(A7/W35) kW 12 14 16
Heating(A2/W35) kW 9.46 10.89 12.22

404
361
330
Heating(A-7/W35) kW 11.66 12.72 14.92
Cooling(A35/W18) kW 14.60 15.50 16.80
4 Holes for anchor bolts
Nominal Input Heating(A10/W35) kW 3.02 3.49 4.1
Heating(A7/W35) kW 2.72 3.24 3.81
Heating(A2/W35) kW 2.83 3.28 3.82
Heating(A-7/W35) kW 4.31 4.98 5.95
N° ITEM
Cooling(A35/W18) kW 4.02 4.65 5.09
1 Liquid side service valve(mm)
COP Heating(A10/W35) W/W 4.39 4.32 4.23 2 Gas side service valve(mm)
Heating(A7/W35) W/W 4.41 4.32 4.20 3 Air discharge grill
Heating(A2/W35) W/W 3.34 3.32 3.20 4 Control Cover
Heating(A-7/W35) W/W 2.71 2.55 2.51
EER Cooling(A35/W18) W/W 3.63 3.33 3.30
Sound Heating dBA 53
pressure level
Cooling dBA 54
Dimension W*H*D mm 950*1,380*330
Weight kg 105
Refrigerant Pre-charged amont g 2,980
(R410A)
Pipe Diameter(Liquid/Gas) inch 3/8, 5/8

LG Air Conditioners 2011 18 / 19

2011_Therma_V_Final_Tomi.indd 18-19 2011.05.06. 12:39:36


Outdoor Unit (1ø 230V)
Maximum 55ºC Leaving Water Temperature

THERMA V
N*Afb][lagf
OUTDOOR UNIT
)¬$+¬ HUV121. U31 12kW

HUV141. U31 14kW

HUV123. U31 12kW

HUV143. U31 14kW

4-holes for anchor bolts

390

360

330
Specifications
Outdoor Unit HUV121. U31 HUV141. U31 HUV123. U31 HUV143. U31
Combined Indoor Unit
Hydro Kit
HN1616.NK1 Supporter
HN1626.NK1
HN1636.NK1
HN1629.NK1
HN1639.NK1

1,380

1,356
Power Supply ø/ V / Hz 1ø / 220-240V / 50Hz 3ø / 380-415V / 50Hz

Nominal Capacity Heating(A10/W35) kW 13.10 14.69 13.10 14.69


Heating(A7/W35) kW 12.00 14.00 12.00 14.00
Heating(A2/W35) kW 9.85 11.05 9.85 11.05

490
Heating(A-2/W35) kW 12.11 13.58 12.11 13.58
Cooling(A35/W18) kW 12.00 14.00 12.00 14.00
Nominal Input Heating(A10/W35) kW 3.05 3.34 3.05 3.34 165 620 165

Heating(A7/W35) kW 2.82 3.32 2.82 3.32 400


950

Heating(A2/W35) kW 3.14 3.44 3.14 3.44


Heating(A-2/W35) kW 5.16 5.71 5.16 5.71
Cooling(A35/W18) kW 3.33 3.88 3.33 3.88 N° ITEM

COP Heating(A10/W35) W/W 4.30 4.40 4.30 4.40 1 Liquid side service valve(mm)

Heating(A7/W35) W/W 4.26 4.22 4.26 4.22 2 Gas side service valve(mm)

Heating(A2/W35) W/W 3.14 3.21 3.14 3.21 3 Air discharge grill

Heating(A-2/W35) W/W 2.35 2.38 2.35 2.38 4 Control Cover

EER Cooling(A35/W18) W/W 3.60 3.61 3.60 3.61


Peak Data Heating Capacity kW 12.28 13.78 12.28 13.78
at A-15/W35 (*)
COP W/W 2.32 2.35 2.32 2.35
Sound Heating dBA 54
pressure level
Cooling dBA 53
Dimension W*H*D mm 950*1,380*330
Weight(Net) kg 105
Refrigerant Pre-charged amont g 3,400
(R410A)
Pipe Diameter(Liquid/Gas) inch (3/8)/(5/8)

›8mX`cXYc\]ifd8l^ljk
(*) : Heating steady-state performance without defrost effect

LG Air Conditioners 2011 20 / 21

2011_Therma_V_Final_Tomi.indd 20-21 2011.05.06. 12:39:40


Outdoor Unit (1ø 230V)
Maximum 55ºC Leaving Water Temperature

THERMA V
OUTDOOR UNIT
EGFGW)¬ HM091M. U31 9kW

HM121M. U31 12kW

HM141M. U31 14kW

165 620
3 165 13
13 50 40

218
150
30
2

404
361
330
Specifications
4 Holes for anchor bolts
Outdoor Unit HM091M. U31 HM121M. U31 HM141M. U31
Power Supply ø/ V / Hz 1ø / 220-240V / 50Hz
Nominal Heating(A10/W35) kW 10.58 12.7 14.68 5

Capacity Heating(A7/W35) kW 10 12 14
Heating(A2/W35) kW 5.67 6.83 8.57
Heating(A-7/W35) kW 7.40 9.0 11.05 6
7
Cooling(A35/W18) kW 10.00 12.00 14.00

1380
1356
Nominal Input Heating(A10/W35) kW 2.39 2.91 3.43
Heating(A7/W35) kW 2.35 2.86 3.38
Heating(A2/W35) kW 2.19 2.57 2.99 8 9
Heating(A-7/W35) kW 3.02 3.62 4.23 10
Cooling(A35/W18) kW 2.74 3.33 4.01 11
12
COP Heating(A10/W35) W/W 4.43 4.36 4.28
Heating(A7/W35) W/W 4.26 4.20 4.14 165 620 165

Heating(A2/W35) W/W 2.59 2.66 2.87 950

Heating(A-7/W35) W/W 2.45 2.49 2.61


EER Cooling(A35/W18) W/W 3.65 3.60 3.49
N° ITEM
Sound Heating dBA 53 53 54
pressure level 1 Energy Water Pipe
Cooling dBA 53 53 54
2 Leaving Water Pipe
Dimension W*H*D mm 950*1,380*330
3 Strainer
Weight kg 131
4 Top Cover
Refrigerant(R407C) Pre-charged amount g 3,550
5 Control Box
Leaving Water Heating ºC 20~65
6 Plate Heat Exchanger
Temperature
Cooling ºC 6~25 7 Water Pump
Water Pump Maximum Power Input W 205 8 Pressure Gage
Maximum Head m 7 9 Safety Valve
Minimum Water Flow Rate LPM 12 10 Compressor

LG Air Conditioners 2011 22 /23

2011_Therma_V_Final_Tomi.indd 22-23 2011.05.06. 12:39:45


Outdoor Unit (3ø 400V)
Maximum 55ºC Leaving Water Temperature

THERMA V
OUTDOOR UNIT
EGFGW+¬ HM103M. U31 10kW

HM123M. U31 12kW

HM143M. U31 14kW

165 620 3 165 12


12 50 40

218
150
30
2

404
361
330
Specifications
4 Holes for anchor bolts
Outdoor Unit HM103M. U31 HM123M. U31 HM143M. U31
Power Supply ø/ V / Hz 3ø / 380-415V / 50Hz
Nominal Heating(A10/W35) kW 10.79 12.70 14.81 5

Capacity Heating(A7/W35) kW 10.00 12.00 14.00

Heating(A2/W35) kW 7.36 8.04 8.45

Heating(A-7/W35) kW 9.29 10.83 11.65 6

Nominal Input Heating(A10/W35) kW 2.45 2.90 3.40

1380
1356
Heating(A7/W35) kW 2.35 2.86 3.38

Heating(A2/W35) kW 2.59 2.83 3.06

Heating(A-7/W35) kW 3.37 4.01 4.42 7 8


COP Heating(A10/W35) W/W 4.40 4.38 4.36
9
Heating(A7/W35) W/W 4.26 4.20 4.14 10
11
Heating(A2/W35) W/W 2.84 2.84 2.76

Heating(A-7/W35) W/W 2.76 2.70 2.64 165 620 165

Sound 950
pressure level Heating dBA 53 53 53

Dimension W*H*D 950*1,380*330


N° ITEM
Weight kg 128
1 Energy Water Pipe
Refrigerant(R407C) g 3,550
2 Leaving Water Pipe
Leaving Water
Temperature Heating ºC 20~65 3 Strainer

4 Top Cover

5 Control Box

6 Plate Heat Exchanger

7 Pressure Gauge

8 Safety Valve

9 Compressor

LG Air Conditioners 2011 24 / 25

2011_Therma_V_Final_Tomi.indd 24-25 2011.05.06. 12:39:51


An Indoor Box for MONOBLOC 3ø

THERMA V
Af\ggj:gp
The indoor box contains an electric backup heater and a water pump.
The traditional MONOBLOC includes an electric back-up heater and a water pump in the outside unit.
LG’s ‘3-phase’ MONOBLOC puts the water pump in the indoor box so that it keeps the water pump
]ifdY\`e^]ifq\eXj`k`j`ejkXcc\[`ej`[\k_\Yl`c[`e^j\gXiXk\cp%
It also generates additional heat energy with an electric back-up heater.

Specifications
Outdoor Unit CHN1426. NK1 CHN1436. NK1 CHN1429. NK1 CHN1439. NK1
Electric Heater Power Supply ø/V/Hz 3ø / 220V / 50Hz 3ø / 380-415V / 50Hz 3ø / 220V / 50Hz 3ø / 380-415V / 50Hz

Capacity Kw 6 6 9 9

Water Pump Maximum Power Input W 205 205 205 205

Maximum Head m 7 7 7 7

Minimum Water Flow Rate(LPM) 15 15 15 15

Dimension W*H*D mm 490*850*315 490*850*315 490*850*315 490*850*315

Weight kg 38 38 38 38

Water Connections Entry / Leaving mm 25 / 25 25 / 25 25 / 25 25 / 25

Safety Valve Relief Pressure Bar 3 3 3 3

INDOOR BOX
474 305
N° ITEM
9 1 Energy Water Pipe

7
2 Leaving Water Pipe

3 Control Panel
6
10 4 Water Pump

5 Safety Valve

6 Thermal Switch
848

13 7 Control Box
5

8 Pressure Gage

8 9 Air Vent

10 Electronic Heater
4
11 Strainer
3
12 Shut-off Valve

13 Carrying Handle
1 2

12 12

11
66

39

52
266 100 75.1
474

N A T U R A L H E A T I N G M A C H I N E

LG Air Conditioners 2011 26 / 27

2011_Therma_V_Final_Tomi.indd 26-27 2011.05.06. 12:39:57


THERMA V
Sanitary Water
SANITARY WATER TANK – SINGLE COIL
Tank LGRTV200E 198 LITERS

LGRTV300E 287 LITERS

SANITARY WATER TANK – SINGLE COIL


SANITARY WATER TANK LGRTV200E LGRTV300E
GENERAL CHARACTERISTICS
Water Volume L 198 287
Diameter mm 580 580
Height mm 1230 1680
Empty Weight kg 45 59
Tank – Materials Stainless steel Stainless steel
Outer Skin – Materials Paint Epoxy Paint Epoxy
Color – White RAL White NC White NC
CHARACTERISTICS OF ELECTRICAL BACK-UP
Additional Electric Heater kW 3 3
Adjustable Thermostat ºC 60 ~ 90 60 ~ 90
CHARACTERISTICS OF EXCHANGER
Exchanger Type Single Single
Material Exchanger LDX 2101 – Stainless steel LDX 2101 – Stainless steel
Maximum Water Temperature ºC 80 80
HYDRAULIC CONNECTIONS – HEAT PUMP
THERMA V Entry mm 25 25
THERMA V Exit mm 25 25 SANITARY WATER TANK – DOUBLE COIL
HYDRAULIC CONNECTIONS – SANITARY WATER
City Water Entry mm 22 22 LGRTV200VE 198 LITERS
Hot water Exit mm 22 22
ELECTRIC CONNECTION LGRTV300VE 287 LITERS
Supply ø/V/Hz 1ø/220-240V 50Hz 1ø/220-240V 50Hz

MANDATORY OPTIONAL ACCESSORIES


Sanitary Tank Installation Kit PHLTA PHLTA

SANITARY WATER TANK – DOUBLE COIL


SANITARY WATER TANK LGRTV200VE LGRTV300VE
GENERAL CHARACTERISTICS
Water Volume L 198 287
Diameter mm 580 580
Height mm 1230 1680
Empty Weight kg 50 64
Tank – Materials Stainless steel Stainless steel
Outer Skin – Materials Paint Epoxy Paint Epoxy
Color – White RAL White NC White NC
CHARACTERISTICS OF ELECTRICAL BACK-UP
Additional Electric Heater kW 3 3
Adjustable Thermostat ºC 60 ~ 90 60 ~ 90
CHARACTERISTICS OF EXCHANGER
Exchanger Type Double Double
Material Exchanger LDX 2101 – Stainless steel LDX 2101 – Stainless steel SOLAR PANELS FOR DOUBLE COIL TANK
Maximum Water Temperature ºC 80 (With an Heat Pump) 80 (With an Heat Pump)
HYDRAULIC CONNECTIONS – HEAT PUMP For better performance and energy saving, it is possible to
THERMA V Entry mm 25 25 combine the THERMA V heat pump with solar panels.
THERMA V Exit mm 25 25
HYDRAULIC CONNECTIONS – SANITARY WATER
City Water Entry mm 22 22
Hot water Exit mm 22 22
ELECTRIC CONNECTION
Supply ø/V/Hz 1ø/220-240V 50Hz 1ø/220-240V 50Hz

MANDATORY OPTIONAL ACCESSORIES


Sanitary Tank Installation Kit PHLTA PHLTA

LG Air Conditioners 2011 28 / 29

2011_Therma_V_Final_Tomi.indd 28-29 2011.05.06. 12:40:01


>d]paZd]9hhda[Ylagf^gjF]o:mad\af_k

Application 1 Application 3
> Monovalent operation mode > Monovalent operation mode
> Functions : > Functions :
›Le[\i]cffi?\Xk`e^›CfnK\dg\iXkli\IX[`Xkfij ›Le[\i]cffi?\Xk`e^
›JXe`kXip?fkNXk\i1?\Xkgldg"8[[`k`feXc<c\Zki`ZKXeb

Controller

Check Valve

Check Valve

Application 2 Application 4
> Monovalent operation mode > Monovalent operation mode
> Functions : > Functions :
›Le[\i]cffi?\Xk`e^›CfnK\dg\iXkli\IX[`Xkfij ›CfnK\dg\iXkli\IX[`Xkfij
›JXe`kXip?fkNXk\i1?\Xkgldg"8[[`k`feXc<c\Zki`ZKXeb"JfcXiGXe\cj

Check Valve

Check Valve

Warning : Warning :
The recommended installation schemes are provided as a rough guide and are not a substitute for any centric heating design. LG is not responsible The recommended installation schemes are provided as a rough guide and are not a substitute for any centric heating design. LG is not responsible
for damage resulting from not following this warning. for damage resulting from not following this warning.

LG Air Conditioners 2011 30 / 31

2011_Therma_V_Final_Tomi.indd 30-31 2011.05.06. 12:40:01

Potrebbero piacerti anche