Benefits
AIR CONTAMINATION
Quality Matters
INCREASED
SYSTEM
DOWNTIME
REDUCED
PRODUCTION
EFFICIENCY
QUALITY
CLASS
DIRT
Particle size
in Micron
WATER
OIL
Pressure Dewpoint C
(Including
(ppm. vol.) at 7 bar g vapour) mg/m3
0.1
-70 (0.3)
0.01
-40 (16)
0.1
-20 (128)
1.0
15
+3 (940)
40
+7 (1240)
25
+10 (1500)
Fixing Clamp
Joins two filters and is a wall
mounting bracket in one!
Unique Filter Element
Is available in four filtration
grades.
Built in Safety
Simply push for autodrain check
and bowl depressurisation.
Technical Specifications
Filter Grade
GP, HE
AC, DP
Pipe
Size
NPT
(Grade) 19
(Grade) 40
Flow Rates
@ 100 psi g (7 bar g)
Dimensions (inches)
C
Weight
lbs.
cfm
m3/min
1/4
19
0.53
3.5
2.0
9.8
4.0
2.2
3/8
40
1.12
3.5
2.0
10.4
4.0
2.8
(Grade) 64
1/2
64
1.80
3.5
2.0
11.3
4.0
2.4
(Grade) 123
3/4
123
3.45
5.1
2.6
13.8
5.5
5.0
(Grade) 216
216
6.05
5.1
2.6
17.5
5.5
5.7
(Grade) 275
1 1/4
275
7.70
5.1
2.6
19.8
5.5
6.3
(Grade) 350
1 1/2
350
9.80
6.3
3.5
22.8
6.9
10
(Grade) 481
1 1/2
481
13.46
6.3
3.5
27
6.9
14.5
(Grade) 563
563
15.76
6.3
3.5
29.5
6.9
15.8
(Grade) 706
706
19.76
6.3
3.5
34
6.9
17.4
(Grade) 850
2 1/2
850
23.80
8.2
4.0
37
9.8
31.3
(Grade) 1100
1100
30.80
8.2
4.0
40.8
9.8
33.5
1380
38.63
8.2
4.0
43.7
9.8
36
210
(Grade) 1380
*(Grade) 2100
2100
60.0
17.7
7.9
44.8
25.5
(Grade) 2750
2750
78.0
19.6
9.0
48
25.5
298
(Grade) 4100
4100
117
22.8
10.7
50.9
25.5
390
(Grade) 7000
7000
195
29.5
14.2
59.8
25.5
812
(Grade) 11000
10
11000
312
29.1
16
66.2
31.5
1135
(Grade) 17000
12
17000
468
39.3
19
70
33.4
1506
*
B
Operating Limitations
Maximum operating
pressure
Maximum recommended
operating temperature
(Grade GP/HE/DP)
232 psi g
(16 bar)
150F
(66C)
Maximum recommended
operating temperature
(Grade AC)
86F
(30C)
Minimum recommended
operating temperature
34F
(1.0C)
Clearance to
change element
Clearance to
change element
1900-1380 CFM
2199-16527 CFM
15
1
0.38
29
2
0.53
44
3
0.65
73
5
0.85
100
7
1.0
131
9
1.13
160
11
1.25
189
13
1.36
218
15
1.46
232
16
1.51
Ingersoll-Rand air compressors are not designed, intended or approved for breathing air. Compressed air should not be used
for breathing air applications unless treated in accordance with all applicable codes and regulations.
Nothing contained in this brochure is intended to extend any warranty or representation, expressed or implied, regarding
the products described herein. Any such warranties or other terms and conditions of sale shall be in accordance with
Ingersoll-Rands standard terms and conditions of sale for such products which are available upon request.
Product improvement is a continuing goal at Ingersoll-Rand. Designs and specifications are subject to change without
notice or obligation.
Ingersoll-Rand Company