INTRODUCTION
Three phase inverters

Three-phase inverters are used for variable-frequency drive applications and for high power
applications such as HVDC power transmission. A basic three-phase inverter consists of
three single-phase inverter switches each connected to one of the three load terminals. For
the most basic control scheme, the operation of the three switches is coordinated so that one
switch operates at each 60 degree point of the fundamental output waveform. This creates a
line-to-line output waveform that has six steps. The six-step waveform has a zero-voltage
step between the positive and negative sections of the square-wave such that the harmonics
that are multiples of three are eliminated as described above. When carrier-based PWM
techniques are applied to six-step waveforms, the basic overall shape, or envelope, of the
waveform is retained so that the 3rd harmonic and its multiples are cancelled.

PDF created with pdfFactory Pro trial version www.pdffactory.com

TECHNICAL SPECIFICATIONS
POWER CIRCUIT
1. Build in three phase gate drive signal generator with 180 and 120 degree conduction mode .
2. Conduction mode selection by switch whether 180 or 120 degree.
3. Build in three phase IGBT bridge circuit with dually connected with power supply.
4. Power supply is 12 or 24 v.
5. Six gate pulses are provided to monitor.
6. Gate drive signals isolated and dead time introduced.
7. Only gate signals to be connected to IGBT Bridge circuit.
8. Build in three phase R Load to load inverter.
9. IGBT in bridge:

: three phase bridge circuit is build in with six IGBT of FGA25N120

5. Output Load

:100 ohms, 10 watts Resistor

PDF created with pdfFactory Pro trial version www.pdffactory.com

OPERATING PROCEDURE
1. Connect the isolated gate drive signals terminals marked G1, G2, G3, G4, G5 and G6 to
corresponding terminals in igbt bridge.
2. The output Marked in three phase bridge circuit R,Y and B . Connect it to Output load circuit
as per shown.
3. Select the conduction mode switch 180 Degree.
4. Now observe the six gate drive signals in CRO and draw it and note down its ON time and
OFF Time.
5. Observe the phase relations of two gate signals in CRO. and note down.
6. Now observe the output waveform across output load as N to R, N to Y, N to B. Notedown
it
7. Observe the Phase to Phase waveforms in CRO and draw the waveforms as per shown.
8. Follow the same procedure for 120 Degree conduction mode.

PDF created with pdfFactory Pro trial version www.pdffactory.com

LAMBDA

Manual for

THREE PHASE IGBT BASED


PWM INVERTER

( Sr. No:............................)

PDF created with pdfFactory Pro trial version www.pdffactory.com

Operating instructions

PDF created with pdfFactory Pro trial version www.pdffactory.com

Potrebbero piacerti anche