DOCUMENT No.

SHEET

e.g. MN-011-01
SUBJECT

OF

e.g. PUNCHING SHEAR DESIGN GROUND FLOOR

REFERENCE
(ACI 318M 05)

CALCULATIONS

OUTPUT

PUNCHING SHEAR
INPUT

(11.12.6)
(11.12.2.1)
(11-33)
(11-34)
(11-35)

(11.12.3)
(11.12.3.1)
(11.12.3.2)
(11.5.7.2)
(11.12.3.3)

DESIGN PARAMETERS:
2
Fc'=
50 N/mm
link =
mm
1010
2
Fyv=
legs A =
420 N/mm
10
no.
legs B =
inner= 1616 mm
10
no.
outside = 1212 mm
links sides =
3
no.
DIMENSIONS:
135.82 mm
A=
200 mm D =
333 mm F =
B=
200 mm ER =
0
mm G =
100 mm
C=
623 mm EL =
600 mm H =
100 mm
SLAB/DROP CAP PROPERTY:
h=
283 mm
co=
30 mm
dx =
247 mm
dy =
233 mm
opening computation =
ave d=
240 mm
manual reduction =
column type =
interior
interior
bo=
1715.95 mm inside perimeter
LOADINGS:
Vu = 2000 kN
Muy = 300 kN.m total moment about y axis
Mux = 300 kN.m total moment about x axis
Vueff =
3486 kN

automatic
0

OUTPUT
A.) Concrete Shear Sapacity (without shear reinforcements)
vc=0.17(1+2/)*(fc')^(0.5)
=
1
ratio of long side to short side of the column
vc=
=
3.61
N/mm2
40
interior column
vc=0.083*(*d/bo+2)*(fc')^(0.5)
vc=
4.46
N/mm2
vc=0.33*(fc')^(0.5)
vc=
2.33
N/mm2
therefore vc=
2.33
N/mm2
and vc=
1.75
N/mm2
concrete shear capacity
Vc=
720.74
kN
shear reinforcement is required
B.) Concrete Shear Capacity (with shear reinforcements)
Vc=0.17*sqrt(fc')*bo*d
maximum concrete shear strength permitted with bars:
Vc=
vc= 0.901561 N/mm2
371.29 kN
Vn= 0.5*sqrt(fc')*bo*d
maximum shear strength permitted with bars:
Vn= 1092.03 kN
increase slab thickness
C.) Design of Shear Reinforcements
A /s= (Vu-Vc)/(fyv*d)
v

41.2
mm2/mm total area around critical shear perimeter
13.7
mm2/mm total area per links side
mm spacing on each side respectively
mm SB=
50
50
D.) Distance from sides of column where stirrups may be terminated (a)
Vu=0.17*sqrt(fc')*bo'*d
Av/s=
Av/s=
SA=

bo' = 16112.5 mm outside perimeter


a=
4784.884 mm
note: always click this button to update a
PROVIDE shear links 10L-T10 @ 50mm on ctr starting d/2 up to 4550mm from column face on side A
PROVIDE shear links 10L-T10 @ 50mm on ctr starting d/2 up to 4550mm from column face on side B

Plan
NOTE: SHEAR LINKS DETAIL FOR INTERIOR COLUMN W/O OPENING ONLY

mm

SHEET

DOCUMENT No.

VERIFIED

OF

SUBJECT

REFERENCE

CALCULATIONS

REMARKS

(ACI 318M 05)

INPUT
DIMENSIONS:
A=
200 mm D =
333 mm G =
600.00 mm
B=
200 mm E =
H=
C=
623 mm F =
136 mm
SLAB/DROP CAP PROPERTY:
h=
283 mm
2a=
9569.769 mm
column type =
interior
bo must be zero
bo=
11754.90 mm
a=
4784.884

100.00 mm
100.00 mm

ER =
EL =

0
600

LOWER

OPENING CASES
INSIDE PERIMETER CASE

OPENING CASES
OUTSIDE PERIMETER CASE

GUIDANCE AND LIMITATIONS NOTES


1 Spreadsheet is prepared only for punching shear for all rectangular or square column.
2 Normal weight of concrete should be used
3 In case light

Revision History
Rev
Date
00
13-Dec-11

Author
RJB

Checker

Approver

Description

Potrebbero piacerti anche