Position

Qty. Description
1

Single Price

S2.100.200.550.4.66M.C.338.G.EX.D

Note! Product picture may differ from actual product

Product No.: 95112792


The submersible S pumps are specifically designed for handling wastewater,
process water and unscreened raw sewage in a wide range of municipal, domestic
and industrial applications.
The S pumps are fitted with 1.65 kW up to 155 kW motors.
Pumps with higher performance are available on request.
The pumps are grouped into the following pump ranges: 34, 42, 50, 54, 58, 62, 66
and 70, each representing a motor size with similar external and internal
dimensions, cooling system, shaft seal and bearings.
Each pump range consists of pump types with different features and performance
range.
The S pumps are provided with SuperVortex, single-channel, two-channel or
three-channel
impeller.
S pumps with SuperVortex impeller can handle solids up to 100 mm in size.
S pumps with channel impeller can handle solids up to 145 mm in size, depending
on the pump range.
Liquid:
Pumped liquid:
Liquid temperature range:
Density:

Any Newtonian liquid


0 .. 40 C
998.2 kg/m

Technical:
Actual impeller diameter:
Type of impeller:
Maximum particle size:
Primary shaft seal:
Secondary shaft seal:
Approvals on nameplate:

338 mm
2-CHANNEL
100 mm
SIC-SIC
SIC-CARBON
94/9/EC(ATEX)

Materials:
Pump housing:

Impeller:

Motor:

Installation:
Range of ambient temperature:
Flange standard:
Pump inlet:
Pump outlet:
Pressure stage:
Printed from Grundfos CAPS [2013.01.087]

Cast iron
EN-GJL-250
AISI A48 30
Ductile cast iron
EN-GJS500-7
AISI 80-55-06
Cast iron
EN-JL1040
AISI A48 30

-20 .. 40 C
DIN
250
200
PN 10
1/8

Position

Qty. Description

Single Price

Auto-coupling:
Frame range:

96641489
66

Electrical data:
Number of poles:
Maximum current consumption:
Power input - P1:
Rated power - P2:
Mains frequency:
Rated voltage:
Voltage tolerance:
Start. method:
Max starts per. hour:
Starting current:
Rated speed:
Motor efficiency at full load:
Motor efficiency at 3/4 load:
Motor efficiency at 1/2 load:
Enclosure class (IEC 34-5):
Insulation class (IEC 85):
Explosion proof:
Ex-protection standard:
Length of cable:
Cos phi 1/1:
Cos phi 1/2:
Cos phi 3/4:

4
108 A
61 kW
58 kW
50 Hz
3 x 400/690 V
+10/-10 %
star/delta
15
1040 A
1487 rpm
95 %
94 %
94 %
IP68
F
yes
60079-0, 60079-1
10 m
0,82
0,63
0,75

Others:
Net weight:

1130 kg

Printed from Grundfos CAPS [2013.01.087]

2/8

95112792 S2.100.200.550.4.66M.C.338.G.EX.D 50 Hz
H
[m]

S2.100.200.550.4.66M.C.338.G.EX.D, 50Hz

eta
[%]

Q = 254 l/s
H = 12.4 m

40

35

30

25

100

20

80

15

60

10

40

20

Eta pump = 55.2 %


Eta pump+motor = 52.4 %

0
0

20

40

60

80

100

120

140

160

180

200

220

240

260

280

P
[kW]
60

Q [l/s]
NPSH
[m]

P1

30

P2
50

25

40

20

30

15

20

10

10

Printed from Grundfos CAPS [2013.01.087]

5
P1 = 58.8 kW
P2 = 55.8 kW
NPSH = 7.6 m

0
3/8

Description
Product name:
Product No:
EAN number:

H
[m]

Value

S2.100.200.550.4.66M.C.338.G.EX.D, 50Hz

eta
[%]

Q = 254 l/s
H = 12.4 m

S2.100.200.550.4.66M.C.338.G.E
X.D
95112792
5700310620237

40
35
30

254 l/s
280 l/s
12.4 m
37.8 m
338 mm
2-CHANNEL
100 mm
SIC-SIC
SIC-CARBON
94/9/EC(ATEX)
with cooling jacket

25

100

20

80

15

60

10

40

Eta pump = 55.2 %


Eta pump+motor = 52.4 %

0
0

50

100

150

200

250

P1

40

Cast iron
EN-GJL-250
AISI A48 30
Ductile cast iron
EN-GJS500-7
AISI 80-55-06
Cast iron
EN-JL1040
AISI A48 30

Printed from Grundfos CAPS [2013.01.087]

296

24
8
1638

318

1320
W2

215

26

DN200

460

809

20

720
V2

W2
V2
U2
W1

T2

U1

V1

W1
U1

Optional
equipment

Item No. 176a

6
5

V2
U2

t+

Stator conductors

P3

T1

T2
8

Item
1
2
3
4
3

Item No. 176c

Item No. 520

3
4

4
4

4
2
5

P1

P3

P2

T1

t+

t+

t+

t+

Pt100 stator

Thermistor

+
Pt100 lower bearing

V1

Cable conductors

W2

W1

V2

V1

U2

W2

W2
W2

W1

W1

V1
V2

U2

V1

3
V1

U2

U1

V2

U1

U1

W1

Motor
U1

Moisture switch and thermal protectors.

Read clockwise
from ground

P2
P3
3
3
3
1
6

Thermal switch

In Ex-pumps 2 pcs.Moisture switch

P3

P1
1

2
2

4/8

4
108 A
61 kW
58 kW
50 Hz
3 x 400/690 V
+10/-10 %
star/delta
15
1040 A
1487 rpm
95 %
94 %
94 %
IP68
F
yes
60079-0, 60079-1
KLIXON
10 m
2X4X25MM2+1X7X1,5MM2
0,063 Ohm
0,82
0,63
0,75

Electrical data:
Number of poles:
Maximum current consumption:
Power input - P1:
Rated power - P2:
Mains frequency:
Rated voltage:
Voltage tolerance:
Start. method:
Max starts per. hour:
Starting current:
Rated speed:
Motor efficiency at full load:
Motor efficiency at 3/4 load:
Motor efficiency at 1/2 load:
Enclosure class (IEC 34-5):
Insulation class (IEC 85):
Explosion proof:
Ex-protection standard:
Motor protec:
Length of cable:
Cable size:
R:
Cos phi 1/1:
Cos phi 1/2:
Cos phi 3/4:

Any Newtonian liquid


0 .. 40 C
998.2 kg/m

Liquid:
Pumped liquid:
Liquid temperature range:
Density:

400

-20 .. 40 C
DIN
250
200
PN 10
C
D/S
vertical
96641489
66

P1 = 58.8 kW
P2 = 55.8 kW
NPSH = 7.6 m

U2

Installation:
Range of ambient temperature:
Flange standard:
Pump inlet:
Pump outlet:
Pressure stage:
Installation:
Inst dry/wet:
Installation:
Auto-coupling:
Frame range:

10

20

Motor:

15

P2

Impeller:

0
NPSH
[m]

60

Materials:
Pump housing:

20

Q [l/s]

P
[kW]

Description
Female push-on
Wire pin
Butt splice
Ring connector

Technical:
Actual calculated flow:
Max flow:
Resulting head of the pump:
Head max:
Actual impeller diameter:
Type of impeller:
Maximum particle size:
Primary shaft seal:
Secondary shaft seal:
Approvals on nameplate:
Cooling jacket:

5
0

Description

Value

Controls:
Water-in-oil sensor:

without water-in-oil sensor

Others:
Net weight:

1130 kg

Printed from Grundfos CAPS [2013.01.087]

5/8

95112792 S2.100.200.550.4.66M.C.338.G.EX.D 50 Hz

400
720

1320

1638

26
20

24
8

DN200

318

215
296
460
809

Note! All units are in [mm] unless others are stated.


Disclaimer: This simplified dimensional drawing does not show all details.
Printed from Grundfos CAPS [2013.01.087]

6/8

131
150

365

0
4 X M24

196
485

31

430

295

535

761

86

3
3

222

852

8 x 23

DN200

170

200

1570

1201

809

Min level
Installation S

Min level
Installation C

1638

720

1769

95112792 S2.100.200.550.4.66M.C.338.G.EX.D 50 Hz

Note! All units are in [mm] unless others are stated.


Disclaimer: This simplified dimensional drawing does not show all details.
Printed from Grundfos CAPS [2013.01.087]

7/8

95112792 S2.100.200.550.4.66M.C.338.G.EX.D 50 Hz
Thermal switch
1

P1

P3

In Ex-pumps 2 pcs.Moisture switch


2

Moisture switch and thermal protectors.

Read clockwise
from ground
Motor

P3
6

U1

P2

Pt100 lower bearing

4
5
6

4
5
6
7

U1
V1

U2
V1

Pt100 stator
+

t+

V2

Thermistor

T1

W1

t+
8

W1

t+

t+

t+

U2

W2

T2

2
3
4
5

U1

U1

U2

V1

V2

W1

W2

U2
V1
V2
W1

6
W2

V2

W2

Cable conductors
1
2
3

Item No. 176c

Item No. 520

U1

V1

W1

U2

V2

W2

5
6

4
P3

Item No. 176a


P3

U1

P1

V1

W1

U2

V2

W2

P2
5

1
4

T2
T1

Stator conductors

Item
1
2
3
4

Description
Female push-on
Wire pin
Butt splice
Ring connector

Optional
equipment

Note! All units are in [mm] unless others are stated.


Printed from Grundfos CAPS [2013.01.087]

8/8