INPUTS
PRESETS
STORE
ZOOM
VSC Remote
System
Remote
IR Remote Control
Hex Codes and Signal Timing
Guide to Hex Codes and Signal Timing for
Extron IR Remote Controls
68-1323-01
Rev. A
10 06
Hex codes
Looking up the Hex Code
To find the hex codes for your individual Extron IR remote
control, match your button positions with those in figure 1, then
look up the corresponding button number in the hex code table
(e.g., button #15 [arrowed] has the hex code 0E).
N
Your remote control will not have all the buttons shown.
Figure 1 below covers the button combinations of all
available Extron IR remote models.
Button #
1
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
Hex Code
00
01
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
0F
10
11
12
13
14
15
16
17
Button #
Hex Code
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
18
19
1A
1B
1C
1D
1E
1F
40
41
42
43
44
45
46
47
48
49
4A
4B
4C
Signal Timing
Example
The figure below shows the transmitted signal to represent a
single press of button #15.
Data Bits Transmitted
Code
Device Address
1st Frame
Inverse Code
Byte 3
Byte 2
Byte 1
Lead Code
Byte 4
0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 1 1 1 0 1 1 1 1 0 0 0 1
0
9 ms
4.5 ms
1st Frame
Lead Code
Code
Byte 2
Byte 1
Inverse Code
0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 D0 D1 D2 D3 D4 D5 D6 D7 D0 D1 D2 D3 D4 D5 D6 D7
0
9 ms
4.5 ms
2.5 ms
Repeat Code
Carrier On
Carrier Off
9 ms
Bit Description
Bit 0
0.56 ms
Bit 1
Carrier On
Carrier Off
0.56 ms
Carrier On
Carrier Off
0.56 ms
1.125 ms
2.25 ms
Tf = 108 ms
Lead Code
Bytes 1-4
Tf = 108 ms
Repeat Code
Repeat Code