Sei sulla pagina 1di 3

(SEBP3654 - ) - Service Information System

Pgina 1 de 3

Shutdown SIS
Previous Screen
Product: TRACK-TYPE TRACTOR
Model: D8T TRACK-TYPE TRACTOR KPZ
Configuration: D8T TRACK-TYPE TRACTOR KPZ00001-UP (MACHINE) POWERED BY C15 Engine

Troubleshooting
D8T, D9T, D10T and D11T Track-Type Tractors
Media Number -RENR8056-08

Publication Date -01/07/2011

Date Updated -19/07/2011

i03213972

MID 113 - CID 2121 - FMI 07


SMCS - 1435-038-FWD
Conditions Which Generate This Code:

https://127.0.0.1:444/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/si... 11/12/2014

(SEBP3654 - ) - Service Information System

Illustration 1

Pgina 2 de 3

g01640476

Schematic of the Forward Switch

This diagnostic code is recorded when status of the direction switch is wrong. When the switch is in
REVERSE, the Normally Open circuit is grounded and the Normally Closed circuit is open. When the
switch is in FORWARD or NEUTRAL, the Normally Open circuit is open and the Normally Closed
circuit is grounded. A diagnostic code is recorded when the status of the direction switch does not
match the signal from the position sensor (direction selector). There will be no backup system for the
position sensor (direction selector) if the sensor fails.
Test Step 1. CHECK THE DIRECTION SWITCH.
A. Check the screws that hold the direction switch to the console. Tighten any loose screws.

https://127.0.0.1:444/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/si... 11/12/2014

(SEBP3654 - ) - Service Information System

Pgina 3 de 3

B. If the problem persists, loosen the screws on the direction switch and rotate the switch slightly.
C. Tighten the screws. Change the direction of the machine and then determine if the diagnostic
code is still present.
D. If the problem still exists, loosen the screws on the direction switch. Rotate the switch in the
opposite direction slightly.
E. Tighten the screws. Change the direction of the machine and then determine if the diagnostic
code is still present.
F. Determine if the CID 2121 FMI 07 is present.
Expected Result:
The CID 2121 FMI 07 diagnostic code is present.
Results:
OK - The CID 2121 FMI 07 diagnostic code is present.
Repair: The problem has not been corrected. The direction switch may have failed. Replace the
direction switch. Exit this procedure and perform the diagnostic code procedure again. If the
problem persists, the ECM may have failed. Prior to replacing an ECM, always contact your
dealership for possible consultation with Caterpillar. This consultation may greatly reduce
repair time. See the Troubleshooting, "Electronic Control Module (ECM) - Replace".
STOP
NOT OK - The CID 2121 FMI 07 diagnostic code is not present.
Repair: The problem does not exist at this time. The initial problem was probably caused by a
poor electrical connection or a short at one of the harness connectors that was disconnected and
reconnected. Resume normal machine operation.
STOP
Copyright 1993 - 2014 Caterpillar Inc.

Thu Dec 11 13:37:41 UTC-0430 2014

All Rights Reserved.


Private Network For SIS Licensees.

https://127.0.0.1:444/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/si... 11/12/2014