Sei sulla pagina 1di 22

Name of Work :- Construction of Buildings, Two / Four wheeler parking, Roads & Drains etc.

,
at D-SCC Complex, Ayodhyanagar, Bhopal. (Civil, PH & Electrical works)
PART - A(i) Security Cabin & Rest Rooms - Civil works (Comprising of Morcha, SS
Masonry Jali & M.S. Gate)

Schedule of Quantities
Item
No
1

Rate

Quantity

Description of Item

120.00 SQM Providing and injecting Chemical emulsion for PRECONSTRUCTIONAL Anti-termite treatment and creating
a chemical barrier on top surface of plinth filling, junction
of inside wall and floor, on top of damp proof
course(DPC) or on masonry at the level of plinth filling
as per IS 6313(part-II)-1981 using chemicals like
Chloropyripos emulsifiable (IS: 8944-1978) 20EC mixed
with water in 1:19 ratio (i.e., 1 liter of Chemical to 19
liters of water). The emulsion is spread at 5 lit/sqm on
top surface of plinth filling, top of Damp proof course and
at 1 lit/linear meter along the junction of wall and floor,
all as per specifications and directions. (Plinth area of
the building at Ground floor only shall be measured)

(In words &


figure)

Unit

Amount

SQM

EARTH WORK
2

Earthwork in excavation for FOUNDATION TRENCHES


in ALL KINDS OF SOILS including dressing of sides,
ramming of bottom, disposing the surplus excavated
materials within a distance of 50m and lift 1.50m
complete as per specifications. (Disposed soil to be
leveled by breaking clods if any and neatly dressed).
75.00
7.00

CUM i) Up to 1.50 m below GL

CUM

CUM ii) 1.50 m to 3.0 m below GL

CUM

Earthwork in Excavation over AREAS in HARD ROCK


With CHISELLING upto a depth not exceeding 1.50 mtrs
including depositing and stacking useful materials for
measurements and disposing the waste materials lead
upto 50 mtr etc., complete as directed by the Engineerin-Charge.
38.00

CUM i) Up to 1.5m below GL

CUM

For Office use Only :


No. of Corrections :
No. of Overwriting's :

No. of Deletions :
No. of Omissions :

Item
No

Rate

Quantity

Description of Item

113.00 CUM Filling available excavated approved earth (excluding


rock) in trenches, sides of foundations, plinth, etc; in
layers not exceeding 15cms depth breaking clods,
consolidating each deposited layer by ramming, watering
and dressing, etc; complete for lead upto 50m and all
lifts etc., complete as per specifications.

Earthwork in rough excavation, banking excavated earth


including transportation of earth all leads in layers not
exceeding 20cms in depth, breaking clods, watering,
rolling each layer with half tonne roller of wooden/steel
rammers and rolling every third and top most layer with
power roller of minimum 8 tones / mechnical earth
rammer, consolidating under optimum moisture content
to give not less than 95% of maximum dry density
(proctor density) including dressing, dewatering
wherever necessary in embankments for roads, flood
banks, marginal banks and guide banks or filling up
ground depressions and all lifts of excavation etc.,
complete all as per specifications. NOTE : The
deductions towards voids will be made as per standard
CED Specifications.
800.00 CUM a) In hard soil

(In words &


figure)

Unit

Amount

CUM

CUM

Supplying and filling gravel/copra obtained from


approved quarry in layers not exceeding 150mm in
depth consolidating each layer by ramming with frog
rammer, watering and dressing etc.; complete including
all leads and lifts and all as per specifications.
60.00

CUM a) Under floors/In plinth protection.

CUM

PLAIN CEMENT CONCRETE


Providing and laying cement concrete using
40mm/20mm nominal size graded hard stone aggregate
obtained from approved quarry including compaction,
finishing top surface to level, curing but excluding cost of
formwork, etc.; complete as per specifications. Mix ratio
specified is for (cement: coarse sand: graded stone
aggregate).

a) In foundation and plinth / In sub-base to floors


18.00

CUM i) P.C.C 1:5:10 using 40mm aggregates

CUM

0.25

CUM ii) P.C.C 1:3:6 using 20mm aggregates

CUM

For Office use Only :


No. of Corrections :
No. of Overwriting's :

No. of Deletions :
No. of Omissions :

Item
No

Quantity

Rate
Description of Item

(In words &


figure)

Unit

Amount

Providing damp proof course with cement concrete


using graded hard stone aggregate of 20mm nominal
size obtained from approved quarry, mixed with water
proofing compound of approved quality and brand such
as CICO or ACCOPROOF or equivalent make (2% by
weight of cement) as per manufacturer's specifications
including formwork, compaction, finishing top surface to
level, curing etc.; complete all as per specifications. Mix
ratio specified is for (cement:coarse sand:graded stone
aggregate).

0.75

CUM a) In C.C. 1:1.5:3

CUM

Providing and constructing SIZE STONE MASONRY


using hard stones obtained from approved quarry with
bond stones at every 0.50 sqm of wall surface in cement
mortar in mixes stipulated below without pinning on face,
but including raking out joints and pointing flush in same
mortar including curing, etc.; complete as per
specifications in FOUNDATION AND PLINTH. (Rate
includes cost of bond stones wherever provided). (Mix
ratio specified is for cement : coarse sand)
41.00

CUM a) In cement mortar 1:6

10

CUM

Providing and constructing SIZE STONE MASONRY


using hard stones obtained from approved quarry, with
edges of all stones chisel dressed to obtain uniform size
and shape and in courses not less than 20cms with
bond stones 2mtrs apart in each course including raking
out joints, curing, scaffolding, etc.; complete as per
specifications IN SUPERSTRUCTURE UPTO FLOOR-V
LEVEL.( The mix ratio specified for cement : coarse
sand)The dressing on stones and quoins shall be as
follows:

For Office use Only :


No. of Corrections :
No. of Overwriting's :

No. of Deletions :
No. of Omissions :

Item
No

Rate

Quantity

Description of Item

(In words &


figure)

Unit

Amount

Dressing: Face stones shall be hammer dressed on all


beds and joints, so as to give them approx. rectangular
block shape. These shall be squared on all joints and
beds. The bed joints shall be rough chisel dressed for at
least 5 cm back from the face, and the side joints for at
least 4 cm such that no portion of the dressed surface is
more than 6mm from a straight edge placed on it. The
remaining portion of the stone shall not project beyond
the surface of bed and side joints.. The bushing on the
face shall not project more than 4 cm on an exposed
face and 1 cm on a face to be plastered. The hammer
dressed stone shall also have a rough tooling for a
minimum width of 2.5cm along the four edges of the face
of the stone.
Quoins: The quoins which shall be of the same height as
the course in which these occur, shall be formed of
stones of at least 25cm long, laid stretchers and headers
alternately. These shall be laid square on the beds,
which shall be rough chisel dressed to a depth of at
least 10 cm. These stones shall have a minimum of 2.5
cm wide chisel drafts at four edges. All the edges being
in the same plane.

11

20.00

CUM a) In cement mortar 1:6

CUM

42.00

CUM Providing and laying size stone masonry jali using

CUM

stones of width not less than 150mm with the all edges
chisel dressed and forming a jali structure as per the
drawing using cement mortar 1:4 with joints thickness
not more than 25mm.
12

Providing and constructing BRICK MASONRY in cement


mortar as per mixes stipulated below using approved
well burnt bricks of "CLASS DESIGNATION"
(Classification as per I.S. 1077-1986) as specified below
including raking out joints 10mm deep, scaffolding,
curing, etc.; complete as per specifications IN
SUPERSTRUCTURE UPTO FLOOR V LEVEL. (The mix
ratio specified is for cement : coarse sand)
34.00

SQM a)

USING BRICKS OF CLASS DESIGNATION


"3.5"(Minimum Average Compressive strength not less
than 3.5N/sqm) In cement mortar 1:6

SQM

For Office use Only :


No. of Corrections :
No. of Overwriting's :

No. of Deletions :
No. of Omissions :

Item
No

Rate

Quantity

13

Description of Item

(In words &


figure)

Unit

Amount

Providing and constructing HALF BRICK MASONRY


walls/partitions in the following mixes using FIRST
CLASS well burnt bricks of "CLASS DESIGNATION"
(Classification as per I.S. 1077-1986) as specified below
including scaffolding, raking out joints, curing, etc.;
complete with R.C.C 1:2:4 (1 cement:2 sand:4 graded
stone aggregate of 20mm nominal size) - stiffeners of
size 115mmx75mm at every 900mm centers including
formwork M.S reinforcement consisting of 2 nos. of 6mm
dia M.S bars for main reinforcement with 6mm dia M.S
links at 230mm c/c for each R.C.C stiffener etc.;
complete as per specifications in SUPERSTRUCTURE
UPTO FLOOR-V LEVEL.( The mix ratio specified is for
Cement : Coarse sand )

14.00

CUM a)

USING BRICKS OF "CLASS DESIGNATION


3.5"(Minimum Average Compressive strength not less
than 3.5N/sqm). In cement mortar 1:4

14

CUM

Providing and laying cement concrete using graded hard


stone aggregate of 20mm nominal size obtained from
approved quarry including formwork, compaction,
finishing, curing, etc.; IN BED BLOCKS, ANCHOR
BLOCKS, WINDOW CILLS, COPING BLOCKS, etc.;
upto floor-V level complete all as per specifications. Mix
ratio specified is for (cement: coarse sand: graded stone
aggregate) The work includes providing throating/ drip
mould wherever required as per standard engineering
practice of size not be less than 40mm X 15mm. The
rate is inclusive for making drip mould & no extra cost
will be paid for.
2.00

CUM i) P.C.C 1:3:6

15

CUM

Providing and laying cement concrete in pavements and


ramps in panels not exceeding 10sqm per panel and
plinth protection in panels not exceeding 3sqm per panel
using graded hard stone aggregate including providing
necessary formwork, making 10mm wide grooves in
panels for depth of 1/3 rd. of thickness of pavement or
40mm which ever is more and filling the grooves with
approved hot poured sealing compound confirming to
grade A or B of IS-1834, consolidation, curing and
treatment for the top with broom finish, etc.; complete all
as per specifications, Mix ratio specified is for (cement:
coarse sand: graded stone aggregate).
5.50

CUM a) Using 20mm nominal size aggregate In CC 1:3:6.

CUM

REINFORCED CEMENT CONCRETE :


For Office use Only :
No. of Corrections :
No. of Overwriting's :

No. of Deletions :
No. of Omissions :

Item
No

Rate

Quantity

16

Description of Item

(In words &


figure)

Unit

Amount

Providing and laying in position REINFORCED


CEMENT CONCRETE using graded hard stone
aggregate of 20mm nominal size obtained from
approved quarry including mechanical mixing,
vibrating, compaction, finishing, curing, etc.;
complete all as per specifications but excluding the
cost of form works and steel reinforcement. (Rate to
include labour for keeping embedment's if any,
wherever required while casting). Mix ratio is
specified is for (cement : coarse sand : graded
stone aggregate)
I) RCC 1:1.5:3
17.20

CUM a) All works upto plinth level.

CUM

b) Above plinth & upto floor V level.


21.00

CUM i) In walls (any thickness) including attached parapets,

CUM

fillets, columns, beams, lintels, suspended floors, roofs,


landings, balconies, shelves, chajjas, staircases etc.

17

Providing and laying Ready Mixed Concrete of specified


grade machine batched by weight, machine mixed as
per the design mix standards in the Ready Mix plant and
transported to the place of work. The concrete is made
using graded stone aggregates of maximum 20mm
nominal (down graded) size obtained from approved
quarry including fine aggregates conforming to latest IS
383
and cement all as per the design mix proportions
conforming to IS 10262 with minimum cement content
for durability including supplying and providing concrete
cover etc., which shall be followed as per latest IS 456
including pumping to all heights, placing, spreading,
vibrating, compaction, finishing to required levels, curing
etc., complete all as per specifications but excluding
cost of formwork and steel reinforcement. Rate to
include charges for mixing water proofing compound, if
any specified, and labour for keeping embedments if
any wherever required while casting. Rate also to
include lift charges and scaffolding for all heights /
depths from FFL/GL.

For Office use Only :


No. of Corrections :
No. of Overwriting's :

No. of Deletions :
No. of Omissions :

Item
No

Quantity

Rate
Description of Item

(In words &


figure)

Unit

Amount

obtained from approved quarry including fine aggregates


conforming to latest IS 383 and cement all as per
approved design mix proportions conforming to latest IS
10262 with minimum cement content for durability
including supplying and providing concrete cover blocks
etc., which shall be followed as per latest IS456-2000
including mixing, transporting, placing, vibrating,
compaction, finishing to required levels, curing etc.,
complete all as per specifications but excluding cost of
formwork and steel reinforcement.
NOTE: (1) Ready Mixed Concrete should be from
reputed manufacturers and contractors have to obtain
prior approval of EIC with respect to supplier of RMC. (2)
Cement will not be issued by the department for this
item. (3) Rate to include the transportation with all leads
from RMC plant to the place of work and pumping of
concrete to any height and the rate shall be for all leads.
(4) Cement concrete delivered at site should be
workable and should satisfy all the required standard
tests like cube test and slump test etc., as specified in
code of practice.
Samples taken at site only will be deciding factor. (5)
Department will not have any direct contact in matters
relating to payment, delivery schedule, quality of
concrete etc. It is the responsibility of contractor to
ensure proper co-ordination for the timely supply of
concrete and approved quality product.
(6) Contractor has to make arrangement for proper
approach road (for which nothing extra shall be paid for)
to enable the vehicle carrying concrete to move freely
without any extra cost to the department before ordering
the concrete. However existing approach road may be
made use of for this purpose. (7) Contractor has to
ensure proper strong shuttering / centering to receive
the concrete at all heights. (8) Contractor has to
indemnify the Department arising out of possible dispute
with the manufacturers.
(9) The design mix of RMC of the manufacturer/ supplier
of RMC has to be obtained well in time and approval of
Engineer in Charge to be obtained prior to use. The
design mix should be based on latest IS 456. This
approval has to be obtained whenever the design mix is
changed. The RMC should be supplied confirming to the
approved design mix which shall be continuously
checked during the progress of work. All the quality
checks as per IS stipulations should be scrupulously
followed during the concreting. The work shall be carried
out at all heights
For Office use Only :
No. of Corrections :
No. of Overwriting's :

No. of Deletions :
No. of Omissions :

Item
No

Rate

Quantity

Description of Item

(In words &


figure)

Unit

Amount

A) By using RMC M-20 grade


20.00

CUM a) For all works at all height

18

CUM

Extra for mixing water proofing compound of approved


quality and brand in R.C.C items with ROFFE
HYPROOF manufactured by M/s. Roffe Construction
Chemicals Pvt. Ltd. at 140ml per 50kgs of cement or
CONPLAST X 421 IC of Fosroc Chemicals ltd. at 130ml
per 50 kgs of cement or equivalent approved make
mixed with cement as per manufacturer's specifications
etc., complete all as per specifications. (Rate to include
the cost of water proofing compound).
21.20

CUM a) In M-20 grade concrete in roof slab

CUM

FORMWORK
19

Providing rigid and water tight centering and shuttering


using best quality wood/ plywood/ steel forms and
centering with steel props, acro tubes etc., including
strutting, propping, bracing, staging etc., complete for all
RCC items fixed in position as required including labour
for careful removal of form work etc., complete all as per
specifications at all heights. In Horizontal / Vertical/
slanting surfaces. Rate to include staging, lift charges.

A) For all works upto floor V level


76.50

SQM i) In Foundations, Footings, rafts, plinth beams, Bases of

SQM

columns, Mass concreting, flooring etc.


115.00 SQM ii) In Beams. Lintels, Girders, etc.,
83.00

SQM

SQM iii) In Columns, Pillars, Abutments, posts and struts.

SQM

161.00 SQM iv) In slabs, suspended floors, roofs, landings, shelves


and their supports, Balconies and chejjas

SQM

SQM v) In staircase (except spiral staircase) excluding

SQM

9.00

landings.
52.00

SQM vi) In facias, fins and pergolas

SQM

STEEL

For Office use Only :


No. of Corrections :
No. of Overwriting's :

No. of Deletions :
No. of Omissions :

Item
No

Quantity

Rate
Description of Item

(In words &


figure)

Unit

Amount

Steel reinforcement for all R.C.C items including


decoiling,
cutting,
hooking,
bending,
cranking,
fabricating to required shape, placing in position and
tying the system with soft drawn annealed binding wire
of diameter not less than 1.00mm with 2 strands etc.;
complete all as per specifications at all heights (binding
wire will not be measured for payment).
20

6.00

MT

21

a) With Thermo Mechanically Treated (TMT) bars Fe


500D grade.

MT

Supplying, fabricating, assembling, hoisting/ erecting


and fixing in position at all heights and with all leads,
structural steel works of welded built-up sections, all as
per structural drawings and as per detailed
specifications (for materials and workmanship) in the
situations described hereinafter including
a)cutting of components to required lengths/widths and
shapes/profiles, b)smooth machining of edges/faces , c)
welding (electric arc welding) at joints of built-up
sections/single sections for required weld lengths and
sizes and d) painting all over with two coats of Synthetic
enamel paint of approved quality , make and
colour/shade over one coat of red oxide zinc chromate
primer with surfaces duly prepared to receive painting
etc., complete all as directed by the Engineer-in-charge
NOTE : The Contractor shall submit fabrication shop
drawings for work involved based on construction
drawings (that may be issued during construction period)
for approval by Engineer-in-charge. The fabrication
work shall start only after approval to the fabrication
drawings. Any change required in the fabrication
drawings shall be carried out at no extra cost over the
quoted rates. Fabrication shall be in a perfectly
workmanship like manner and as provided in Section V
and VI of IS 800 and IS 7215.
Welding shall be carried out by qualified welders.
Electrodes for welding, the procedure, selection, test
and inspection shall conform to provisions in IS 816, IS
818, IS 822, and IS 833. Erection/hoisting shall
commence only after passing of fabricated parts by the
Engineer -in- charge.
I)
Structural
steel
works
with
MS
Channels/Angles/Tees/MS Pipes and the like Painting
all over with synthetic enamel paint of approved quality,
make and colour shade over of synthetic enamel primer.

For Office use Only :


No. of Corrections :
No. of Overwriting's :

No. of Deletions :
No. of Omissions :

Item
No

Rate

Quantity

Description of Item

(In words &


figure)

Unit

Amount

a) In framework using MS medium Tubes including


bending to required shapes, Angles, Tees, rods, flats
and other section with all fixtures and fastenings etc.
0.40

MT

0.15

MT

MT

i) For MS gates
b) In MS rectangular/ MS medium tubes

MT

i) For staircase Hand rails


FLOORING:
Note for Marble/ Granite flooring items
1. The brand name / local name specified for the
coloured marble slabs/granite stone slabs are meant for
the approved quality available in the region.
2. White cement wherever specified for items shall be
Birla white or equivalent.

22

23

Providing and laying 18mm thick mirror polished granite


stone slab flooring using 18mm thick mirror polished
granite stone slabs of approved colour and pattern,
machine cut to required size, laid over a bed of 20mm
thick cement mortar 1:6 and cement slurry at the rate of
4.4kg/sqm for bedding, including machine cut edges of
all slabs in order to achieve thin joints including grouting
the joints with cement mixed with pigment to match the
shade of the slabs, finishing to required level and slope,
curing, cleaning, etc., complete all as per specifications
for size of slabs upto 1.0Mtr x 1.0Mtr.
1.50

SQM a) P/L 18mm thick mirror polished granite stone shelves

SQM

22.00

MTR Extra for nosing 18mm thick mirror polished granite

MTR

stone slab in skirting.


24

Providing and laying Indian patent stone flooring with


cement concrete 1:2:4 (1cement: 2 coarse sand: 4
graded stone aggregate) using graded stone aggregate
obtained from approved quarry laid to level or slope in
bays not exceeding 3sqm per panel including providing
3mm thick Aluminum dividing strips to the full depth of
the flooring and finished smooth, curing, etc.; complete
all as per specifications.
5.50

SQM a) In flooring

SQM

9.00

MTR b) In Skirting 125mm high

MTR

For Office use Only :


No. of Corrections :
No. of Overwriting's :

10

No. of Deletions :
No. of Omissions :

Item
No

Rate

Quantity

25

Description of Item

(In words &


figure)

Unit

Amount

Providing and laying Ceramic tile flooring/dadoing of


approved quality, size, colour and thickness according to
the dimensions of tiles and having scratch hardness and
other parameter conforming to IS (Bell or Navin or
spartek or Jhonson or kajaria or somany or equivalent
make) laid over a bed/backing as specified below, with
cement slurry at 3.30kg/sqm, close jointed and pointed
with matching white cement slurry mixed with approved
pigmement and finishing to required level, curing etc.,
complete all as per specification and as directed by
Engineer In charge at all floors.
8.00

SQM a) In flooring with approved colour floor tiles ( Regular /

SQM

plain or dark colour/ glossy or mat series) size 300mm X


200mm or bigger size as per IS over bed/backing of
12mm thick in CM 1:3.
42.00

SQM b) In dado with approved colour wall tiles ( Regular /

SQM

plain or dark colour/ glossy or mat series) size 300mm X


200mm one bigger size as per IS over a bed/backing of
12mm thick in CM 1:3.
26

Providing and laying 20 to 30 mm thick polished KOTA


stone slab flooring/ skirting/ dadoing/ riser/ tread using
slabs, machine cut to required size, laid over a bed of
20mm thick cement mortar 1:4,and cement slurry at the
rate of 4.4 kg/sqm for bedding and 2kg/sqm for joints,
close jointed and pointed with grey cement slurry mixed
with pigments to match the shade of the slabs, finishing
to required level and slope, curing, rubbing, cleaning
with oxalic acid and wax polishing etc; complete all as
per specifications.
84.00

SQM a) In flooring

SQM

55.00

RMT b) In skirting 125mm high.

RMT

27

JOINERY
Supplying and fixing solid hard core non decorative
type(BN) interior grade commercial BLOCK BOARD
FLUSH DOOR SHUTTERS of approved make
conforming to IS-2202 (part-I) - 1991 with teak wood
internal lipping on all sides and solid teak wood inserts
for mounting locks, etc; having well matched commercial
ply veneering with cross bands and face veneers on
both faces, including cost of labour for fixing builder's
hardware and locking arrangement etc; complete all as
per specifications including cost of the following builder's
hardware with three nos. of hinges for each shutter with
necessary screws confirming to ISI for each door.

i) Aluminum aldrop (1 no.)- 250mm with 4 clamps


For Office use Only :
No. of Corrections :
No. of Overwriting's :

11

No. of Deletions :
No. of Omissions :

Item
No

Rate

Quantity

Description of Item

(In words &


figure)

Unit

Amount

ii) Aluminium tower bolt (2 no.) - 250mm


a) Single/ Double shutter
7.00

SQM i) 40mm thick

28

SQM

Providing and fixing at all heights/ in all floors with all


leads Anodised Aluminium doors/ windows/ partitions
manufactured from best extruded Aluminium sections
confirming to ISI, cut to length, joints mitred and corners
grinded with joints water proof the outer frame and
shutter frame stiffened with corner angle strips or
provided for in the frame for fixing the frame to R.C.C
Columns/ masonry on sides, RCC lintels on top and
P.C.C cills or floor at bottom, the frame work fixed with
standard approved fastenings all generally as per
details shown in drawings and specification with all the
sections pretreated for removal of any rust and
prevention of further rust formation and coated with
greasy materials for non-adherence of mortar or any
other sticky materials and this coat to be removed after
installations of the sub-dividing frames by tennoned and
riveted into frames all aluminium surface be thoroughly
cleaned free or rust scale or dirt and mill scale
by pickling surfaces finished with anodised dull matt
finishing 15 MICRON thick including cost of pull and
push plates and fixtures for hinged openings
(arrangement with steel bearings wherever necessary),
cost of labour for fixing of mortice lever locks, aluminium
handles, door fittings like tower bolts etc., supplied free
for fixing including screws / bolts (Or these materials
measured separately elsewhere) where shutters are
involved etc., complete , cost of providing and fixing of
glass of selected glazing quality of thickness and type of
glass specified hereinafter or panel boards including
nylon or PVC or rubber lining of approved quality
wooden grounds, rubber gasket, aluminum glazing clips,
mastic etc., and fixing with aluminum glazing clips and
also snap-on type with holes as per drawing and
specifications provided for separately in the sub items
following the main items of frame work for partition and
door shutters as below: NOTE: All fitting works shall be
carried out as per I.S specifications including necessary
rivets, screws, lugs, scaffolding, etc., complete all
generally as per drawings. The sizes of the components
should confirm as per details in drawings.

For Office use Only :


No. of Corrections :
No. of Overwriting's :

12

No. of Deletions :
No. of Omissions :

Item
No

Quantity

Rate
Description of Item

(In words &


figure)

Unit

Amount

Note: All fittings works shall be carried out as per I.S


specifications including necessary revets, screw, lugs,
scaffolding, etc., complete all generally as per drawings.
The sizes of the components should conform as per
details in drawings.
84.00

KGS a) Providing and fixing of Anodized Aluminum (Matt

KGS

finish) frame work (Styles and rails) for partitions Doors


/Windows with required sections of JINDAL/ INDAL
make or equivalent including providing all items and
hinged/ pivoted arrangement for operation of shutter and
labour cost of fixing of door fittings and locks (Which
shall be free issues for fixing or paid separately) etc.,
complete. (Aluminium beadings and glazing clips
measured under this item only).
32.00

KGS b) Providing and fixing of Anodised Aluminium (Matt

KGS

finish) frame work (Horizontal and verticals) for partitions


Doors /Windows with required sections of JINDAL/
INDAL make or equivalent including all items and
contingencies described above complete (Aluminium
beadings and glazing clips measured under this item
only)
29

Providing and fixing Glass panes of selected glazing


quality and thickness as specified below including
providing and fixing Nylon/rubber/ PVC lining of
approved quality and fixing with Aluminium glazing clips/
Aluminium beadings (Supply cost of Aluminium clips/
Aluminium beadings are measured in items for DOORS /
WINDOWS/ PARTITIONS etc.,
13.00
3.00

SQM a) With 4mm thick plain glass

SQM

SQM d) With 4mm thick plain glass for louvered ventilator

SQM

For Office use Only :


No. of Corrections :
No. of Overwriting's :

13

No. of Deletions :
No. of Omissions :

Item
No

Quantity

30

Rate
Description of Item

(In words &


figure)

Unit

Amount

Providing and fixing 18mm thick door shutters (single or


double) for wardrobe / cupboards / shoe racks made out
of melamine faced prelaminated wood based graded
particle board of BHUTAN or NOVAPAN or equivalent or
melamine aced prelaminated wood based flat pressed
three layered particle board of NOVOPAN or equivalent,
particle bonded with phenol formaldehyde with
decorative laminate on one side and white balancing
laminate on the other side. The boards shall be
manufactured conforming to IS 3087 with teak wood
lipping of 18x10mm on all edges and painting the
beading with synthetic enamel paint to match the colour
of decorative laminate including cost of labour for fixing
builders hardware like hinges, knobs, handles, locks,
tower bolts, etc., complete all as per specifications and
also including cost of builders hardware viz., handles,
Godrej / Europa locks, A1 hinges, A1 tower bolts,
magnetic latches etc; at all heights and levels for
(samples of handles, locks, hinges & tower bolts to be
got approved by EIC.)
A) Cupboard/ wardrobe shutter with decorative laminate
on one side and balancing white on other side
28.00

SQM i) Cup board/Ward robe

31

SQM

Supplying and fixing pressed steel door frames with


rebate as specified below made of pressed steel 1.25
mm thick (conforming to IS:4351-1976):
A) Construction:
i) Each door frame shall consist of hinge jamb, head The
assembly shall be welded or rigidly fixed together by
mechanical means.
ii) Base ties made out of 12mm square rods (2nos.)
which shall be provided for all door frames at threshold
on order to form a rigid unit.
iii) Fixing the frames in position by embedding the lugs in
c.c. 1:3:6 of size
345mm/230mm/115mmx230mmx150mm as required
using 20mm nominal size stone aggregate for wall
location. Further if the frames are builtting to the
RCC/PCC columns/mullions, 8mm of the frame C.C.
1:3:6 etc., complete dia anchor fastner shall be provided
instead of MS hold fasts, filling the hollow space of the
frame with C.C. 1:3:6 etc., complete.
B) Fittings/Embedments:

For Office use Only :


No. of Corrections :
No. of Overwriting's :

14

No. of Deletions :
No. of Omissions :

Item
No

Quantity

Rate
Description of Item

(In words &


figure)

Unit

Amount

i) Fixing lugs: There shall be three adjustable lugs with


split end tail to each jamb without fanlight and four for
jamb with fanlight. The head shall be made from flat
galvansed mild steel strip 25mm wide and not less than
1.60mm thick The tail of lugs shall be made of
Galvanised mild steel strip not less than 40mm wide and
not less than 1mm thick and 20mm long (approx).
ii) Iron oxidised butt hinges conforming to IS 1341-1970
125mm long, 3 nos for each shutter shall be welded to
frame. The hinges shall be 2.5mm thick with removable
pin of 6mm diameter.
iii) Adjustable lock strike plate of Galvanized mild steel
complete with mortar guard 75mm long wooden blocks
shall be provided at top side of frame for tower bolt
female hook and at latch location to make provision for
locks or latches as per I.S.
iv) Shock absorbers - not less than three buffers of
rubber or other suitable materials inserted in holes in the
rebate.
C) Finish:
The door frames shall be painted with a coat of red
oxide zinc chromate primer after pre-treatment of the
surface by pickling and phoshating as specified in I.S.
16.00

MTR a) 'B' profile and fixing 125x60mm with rebate suitable

MTR

for 35mm/38/40mm thick shutters in all floors at all


heights.
32

Supplying of factory made composite door shutter with


frame and single shutter or equivalent with door frame of
size 70x50mm. The door shutter shall be of rigid G.R.P
sandwich composite structure of 26mm thick (minimum)
laminated on all sides with G.R.P skin fabricated using
U.V. stabilized Isopthalic gel coat and one layer of 450
GSM E glass chopped strand mat (CSM) impregnated
with polyester resin.

For Office use Only :


No. of Corrections :
No. of Overwriting's :

15

No. of Deletions :
No. of Omissions :

Item
No

Quantity

Rate
Description of Item

(In words &


figure)

Unit

Amount

The thickness of skins shall not be less than 1.5mm.


Expanded polystyrene structural foam panel of density
20kg/cum shall be used as core material for the whole
areas of door except the wooden frame structure. The
wooden reinforcements made of seasoned salwood
block of minimum cross section of 70x26 for lock side
40x26 all round forming the framework for shutter and
minimum of 75mm wide intermediate strip for the width
of the door for fixing locks and fixture and shall confirm
to IS-4020-1998. The finish of the shutter be without
grains and of approved colour etc., complete all as per
manufacturers specifications at all heights.
5.00

SQM a) 26mm thick shutter.

33

SQM

Providing and fixing M.S grills of required pattern in


wooden / steel frames of windows, ventilators, clerestory
windows, etc.; with M.S flats, square or round bars with
round headed bolts and nuts or by screws, etc.;
complete all as per drawings and directions of Engineerin-charge at all heights..
97.00

KGS Plain grill (with horizontal, vertical members or a

KGS

combination of both)

34

ROOFING
160.00 SQM Providing and laying water proofing treatment over RCC
roof in 3 courses, as specified below, after thoroughly
cleaning surface of the roof slab with wire brush,
cleaning of dust and foreign matters, raking and
cleaning of construction joints if any etc., complete to
make the surface suitable for receiving water proofing
treatment.
I COURSE : The existing covering on slab to be
removed and the surface of the RCC slab exposed.
Construction joints if any are to be raked and cleaned. A
coat of cement slurry at the rate of 4.4kg/sqm mixed with
acrylic water proofing compound (as per manufacturers
specification) is spread uniformly over the RCC roof
area

SQM

and ensuring that the slurry penetrates into the RCC


slab below and fills all micro cracks and all other porous
areas. Over this a layer of 15mm thick cement mortar
1:5, mixed with acrylic water proofing compound as per
manufacturers specifications shall be laid to place the II
course.

For Office use Only :


No. of Corrections :
No. of Overwriting's :

16

No. of Deletions :
No. of Omissions :

Item
No

Quantity

Rate
Description of Item

(In words &


figure)

Unit

Amount

II COURSE : A single layer of brick on edge with 15mm


wide gaps filled with CM 1:5 mixed with acrylic water
compound is laid (i.e., bricks placed vertically on its
75x115mm side or 75x230mm side as the case may be,
to suit the required thickness of course), when the
bottom layer (I course) is still green and laid to slope of 1
in 60 as per roof drainage scheme using approved well
burnt bricks (wear absorption not more than 20%) with
minimum thickness of 65mm at outer edge including the
top and bottom plastering (I & III course) to get required
gradient, laying the bricks with not less than 15mm gap
alround, which shall be properly filled completely and
compacted with CM 1:5 mixed with acrylic water proofing
compound as per manufacturers specification using full
bricks or bricks cut to required size to lay the course with
single layer with gradient said above for adequate
drainage.
III COURSE : 20mm thick cement motar 1:4 mixed with
acrylic water proofing compound with a layer of chicken
mesh 12mmx26G and marked with 300mmx300mm
false squares including curing etc., for not less than 7
days, complete all as per specifications and directions of
Engineer in charge. The 20mm thick layer shall be
carried out in two layers of 10mm thick with an inter
layer of chicken mesh of 12mmx26G laid in between the
two layers of cement mortar. NOTE : The acrylic water
proofing compound to be used shall be; a) CHEMSEAL manufactured by M/s. Overseas Water Proofing
Corporation, Mumbai. The proportion of CHEMSEAL
shall be 2% by weight of cement. OR CONPLAST X 421
IC - integral water proofing compound manufactured by
M/s. FOSROC Chemicals(India) Ltd., Bangalore. The
proportion of CONPLAST X 421 IC shall be 130ml per
50 kgs of cement.
OR
ROFFE HYPROOF
manufactured by M/s. ROFFE Construction Chemicals
Pvt. Ltd., liquid integral water proofing compound at
140ml per 50kg of cement OR Equivalent.

For Office use Only :


No. of Corrections :
No. of Overwriting's :

17

No. of Deletions :
No. of Omissions :

Item
No

Rate

Quantity

Description of Item

(In words &


figure)

Unit

Amount

b) The second course of the treatment shall be laid in


single course using full bricks / cut bricks as may be
required for laying the course in 1 in 60 slope. c) The
rate to include all labour, material and contingent coats
for execution of work in a workman like manner including
curing, etc., complete for respective courses. d) The
plane horizontal measurements of roof slab only shall be
measured for payment. e) The theoretical cement
consumption required for the above work will be worked
out based on co-efficient for each layer of work as per
specification. f) The work shall b got executed through
specialized water proofing agency. g) The contractor
should finish a guarantee bond in the prescribed format
for satisfactory water proofing performance for 10 years.

35

Providing and fixing rigid PVC SWR (soil, waste and rain
water) drainage / rain water pipe conforming to Type-A
IS 13592-1992, including accessories like bends and
fixing with clamp at not more than 1.20m c/c fabricated
using MS flat of 30mmx6mm and 30mmx3mm fixed to
masonry or RCC member using anchor fasteners etc.,.
as per the design and manufacturer's specifications
etc., complete all as per specifications and directions of
Engineer in charge. and directions of Engineer in
charge. Rate to include cost of providing a shoe at the
lower end of each RWP & painting of pipes & clamps
with two coats of synthetic enamel paint of approved
make & colour.
13.50

MTR a) 75mm dia OD pipes with minimum wall thickness of

MTR

1.80 mm.
36

Providing and making khurras of size specified below


with 12mm thick CM 1:3 plaster finish over PCC 1:2:4
using 10mm nominal size stone aggregate (1 cement : 2
fine sand : 4 stone aggregate) of 600mmx600mm of
varying thickness of 40mm at WPC side to 30mm at
pipe end, laid to slope, compacted over PVC sheet of
1000 x 1000mmx 400 micron laid over top of slab after
cleaning the surface of concrete slab. The top surface of
CM 1:3 plaster shall be finished smooth with cement
punning, rounding of edges etc., complete all as per
specifications and directions of Engineer in charge.

Note: The RWP shall be fixed during construction of


parapet to ensure filling the joints and around pipe
properly.
3.00

Nos a) 600mmx600mm size

Each

For Office use Only :


No. of Corrections :
No. of Overwriting's :

18

No. of Deletions :
No. of Omissions :

Item
No

Rate

Quantity

Description of Item

(In words &


figure)

Unit

Amount

FINISHING

Note :
1. The wording "more coats" indicate the additional
coats to be painted, whenever the desired finish has not
been achieved after the application of the specified
number of coats required to be rendered on account of
the above.
2. For plastering items, the rate to include cost of
providing grooves of size 10mm x10mm around doors,
window, ventilators and at junction of dissimilar materials
for internal and external plastering. No extra is
permissible
3. Rates for all finishing items should include lift charges
from FFL/G.L for all heights, depths and levels.
4. All the RCC faces like beam, slabs, lintels, coloums,
flush with internal or external wall faces are plastered
with CM 1:5 and measured under wall plastering and not
under item of CM 1 :4 for RCC surfaces.
5. Rates for all finishing items shall cater for plain or
curved surfaces wherever applicable at all floors and no
extra shall be admissible.
37

Plastering 12/15mm thick with cement mortar specified


below, finished smooth including scaffolding, curing,
etc.; complete for INTERNAL SURFACES of walls,
beam, ribs, sills, jambs, soffits, ceilings, etc., complete
all as per specifications at all heights. Mix specified is for
cement: coarse sand.
175.00 SQM i) 12mm thick in C.M 1:5 with lime neeru

SQM

105.00 SQM ii) 12mm thick in C.M 1:4 with lime neeru

SQM

38

Plastering 12mm/15mm thick with cement mortar 1:4/1:5


specified below, finished rough including scaffolding,
curing etc; complete for EXTERNAL SURFACES
inclusive of skills, jambs, soffits, cellings, etc; complete
all as per specifications at all heights. Mix specified is for
cement: coarse sand.
116.00 SQM I) 12mm thick in C.M. 1:4

SQM

177.00 SQM II) 12mm thick in C.M 1:5

SQM

For Office use Only :


No. of Corrections :
No. of Overwriting's :

19

No. of Deletions :
No. of Omissions :

Item
No

Rate

Quantity

39

Description of Item

(In words &


figure)

Unit

Amount

Pointing on stone work with cement mortar 1:3 (1


cement : 3 fine sand) including raking out joints,
scaffolding, curing, finishing neat, etc; complete all as
per specifications UPTO 10 MTR LEVEL ABOVE G.L
78.00

SQM a) Ruled or sunk pointing.

SQM

40

303.00 SQM Painting external plastered surfaces with two or more


coats of 100% acrylic exterior emulsion paint of
approved make and colour (weather coat of Berger or
apcolite apex of Asian or equivalent) having protection
against fungal growth, flaking, fading, alkali and UV
degradation and to give an even shade with required
finish including cleaning the surfaces, filling the crevices
with approved filler, scaffolding, curing, etc., complete all
as per specifications.

SQM

41

270.00 SQM Painting plastered surfaces with TWO or more coats of


ACRYLIC WASHABLE DISTEMPER of I quality and
approved colour to give an even shade over a coat of
Water thinnable cement primer/ oil based Cement
primer including cleaning the surfaces, filling the
crevices with approved filler,applying a coat of approved
putty on whole surface and rubbing the surface to
achieve desired smooth surface, scaffolding, etc.;
complete all as per specifications at all heights. (Rate to
include cost of primer, putty also).

SQM

42

75.00

SQM Painting wood work with TWO or more coats of

SQM

SYNTHETIC ENAMEL PAINT of I quality and approved


colour to give an even shade over a coat of synthetic
enamel primer including cleaning the surfaces, filling the
crevices with approved filler,applying a coat of approved
putty on whole surface and rubbing the surface to
achieve desired smooth surface, scaffolding, etc;
complete all as per specifications. (Rate to include cost
of synthetic enamel primer, putty also).

43

Painting steel work with TWO or more coats of


SYNTHETIC ENAMEL PAINT of I quality and approved
colour to give an even shade over a coat of red oxide
zinc chromate primer including cleaning the surfaces,
applying a coat of approved putty on whole surface and
rubbing the surface to achieve desired smooth surface,
scaffolding, etc.; complete all as per specifications (
Rate to include cost of zinc chromate primer, putty also).

13.00

SQM a) with primer

SQM

For Office use Only :


No. of Corrections :
No. of Overwriting's :

20

No. of Deletions :
No. of Omissions :

Item
No

5.00

44

Rate

Quantity

30.00

Description of Item

(In words &


figure)

Unit

SQM b) without primer

SQM

SQM Providing and fixing GI hexagonal chicken wire mesh of

SQM

Amount

size 12mm x22g at the junction of dissimilar surfaces of


brick masonry wall and R C column by beams and the
like including necessary nails for fixing etc., complete all
as per specification and direction of Engineer -in -charge
for all floor at all heights.
45

Forming groove of uniform size in the top layer of


washed stone grit plaster as per approved pattern using
wooden batterns, nailed to the under layer including
removal of wooden batterns, repair to the edges of
panels and finishing the groove complete as per
specifications and direction of the Engineer- in- charge.
75.00

46

100.00

RMT 15 mm wide and 15 mm deep groove .

RMT

Kgs Providing and fixing MS round or square guard bars at

KGS

required spacings including welding, grinding, providing


counter sunk holes in the center frame for fixing the
screws for wooden frames etc., of windows/ ventilators/
clerestorey windows, etc: complete all as per drawings
and directions of Engineer-in-charge.

TOTAL Rs.

(Rupees in words. ...


.......... Only)

For Office use Only :


No. of Corrections :
No. of Overwriting's :

21

No. of Deletions :
No. of Omissions :

Item
No

Quantity

Rate
Description of Item

(In words &


figure)

Unit

Amount

For Office use Only :


No. of Corrections :
No. of Overwriting's :

22

No. of Deletions :
No. of Omissions :

Potrebbero piacerti anche