Some help for moshell commands

Site level: can apply grep to all commands (| grep "yyyy-mm-dd")(| grep DXU0040)
amos site#
lt all
alt (active alarms)
lga (history os alarms)
lga | grep -i T1phy (shows on and off time for alarms)
lgv (node in node out)
lge (evry minute activities on site)
lgo (changes on site)
lgs (RAX/TX crashes)
lgs -m 48h (gives hardware crashes)
lgd 60: downtime
hc-????
cabr- see restarts of nodeB
cvls (daily activies on site)
llog (log for restarts on the site)
lgsavemo (To get the history of the site for the working)
pmr -m 2 ( two hourly) (1 gives RSSI -97 to -108)
pmr -m 0.25 (quarterly 15 min rop)
st t1(status of T1's)
lst t1 (shows T1s)
pget t1 (status of T1)
st ima (IMA group status)
lh ru fui get devstat- current generated form the sctor with TMA
st link
st ethernet
get iub plane (gives if the site is ip or atm)
pmx -m 2 t1 s -a (error secs)
get . nodebfunction (it will provide you with the # of channel elements availabl
e (DL and UL)(1rax board = 128ch elements, i.e., 512, then 4 rax board is needed
(4 x 128 = 512) sometimes, the rax board defined is more than what is physicall
y at the site)
HXV3386> get . maxtot-max total power
hget rbs rbslocalcell|localcellid|maxDlPowerCapability
te log read | grep ERROR (gives log on site with errors)
readclock
hget . fq|cellid (to check freq of sectors)
get . Band (gives frequency band)
get rbslocalcell (gives rbs)
st rbs (gives operating state of rbs)
St carrier
lst cell
dump list -a
Get radiolink (gives radiolinks)
lget radiolink noofradio (gives total number of radio links, no radio links is d
isabled cells)
Get cell localcell (gives localid)
Get prach ubch
pmx . pmPropagationDelay -m 1 -a (counters)
pget rach pmprop (counters)
get . maxdl (gives maximumDlPowerCapability)
get ANTFEEDERCABLE (gives feeder attenuation, each sector and branch can be chec
ked against the RNDCIQ)
get feedercable= dlattenuation

get feedercable= ulattenuation


get . atten
get ant att (gives antenna attuenation)
get ant ulatt (gives antenna UL attuenation)
get ant dlatt (gives antenna DL attuenation)
get . internal (gives if tma is powered internally or externally)
get tma
get tma dl (gives TMA DL attenuation)
get tma ul (gives TMA UL attenuation)
lst aal (aal congestion)
cabx | grep RAX (Shows all RAX boards installed in the NodeB)
st aux (Check the Status of Auxillary Units, this will show whether you are deal
ing with an RRU or RU/FUs. With RRU, the interface card is the OBIF and the stan
dard RU/FUs utilise the RUIF)
st ruif/st obif (When the interface hardware is an RUIF, a Status Check of the R
UIF will provide the slot position you will need to allow for polling the board,
If aux shows that the Site has RRUs, then command line will be st obif, Usually
slot convention falls into: macro=12, RRU/Combo Cab=9 and micro=6)
lh ru fui get devstat (gives current, volt, Ulgain, sensitivity=49 means supervi
sion on and txfreq)
lh ru fui get vswr (gives vswr- shud be in 12 to 24 dB range, higher is better 2
0dB is good)
lh ru fui get faults
lhsh 001200/port_4_dev_12 fui get vswr or devstat (gives device status and vswr
for respective port# and dev#) (dualband tma if current ~280mA)
lhsh 001200 ps | grep -i hang (hanging board)
lhsh 001200 ps | grep FU (will give the remote RUIF board for all processes grou
ped by FU- first row will usually be carrier 1 alpha sector and so on)
st rax (checking individual borads and their slot numbers and operational state)
st tx (checking individual borads and their slot numbers and operational state)
st cbu (checking individual borads and their slot numbers and operational state)
lhsh 000slot#00 te log read (gives logs on that particular slot-000600 is slot 6
)
pgets (gives all the enabled counters)
RNC level: can apply grep to all commands (| grep "yyyy-mm-dd")(| grep DXU0040)
amos RNC#
lt all
pmr (8 | grep DXU0040)(8 | sort -k4 -n)
pmx DXU0040 pmNoSystemRabReleaseSpeech m 4 -a (4 hours and aggregate(-a), sum(-s)
)
pmx DXU0040 pmnosysRelSpeechNeighbr (gives number of drops due to missing nbrs)
pmx DXU0040 pmnosysRelSpeechUlSynch m 4 -a (gives drops due to ULsync, last 4 hou
rs aggregated)
alt (active alarms)
get . loadsharingrrcenabled (Should be true(1) in order to activate the load sha
ring)
lget utrancell=DXU1858 loadsharingcandidate (shows all the neighbors for which t
he loadsharingcandidate is true(1) i.e activated)
lget DXU4020C.*DXU4020Z qoffset2sn (shows the qoffset2sn for the respective sour
ce and target cells)
lget DXU0167.*DXU2479 qoffset2sn (shows the qoffset2sn for the respective source
and target sites)
ced | grep DXU0040 (Utran audit)
cedr | egrep '(DXU0167|DXU2479)'|sort +6n (used during live monitoring, shows al
l counters related to power utilization, can be sorted columnwise)
cedr | egrep '(DXU0167|DXU2479)' (used during live monitoring, shows all counter
s related to power utilization)
lget utrancell=CNU1732 frequencyrelationtype 0 (gives all the INTRA defined nbrs

for a site)
lget utrancell=CNU1732 frequencyrelationtype 1 (gives all the INTER defined nbrs
for a site)
lget cnu3229A frequencyrel (same as above)
get utrancell=DXU0040 maximumtransmissionpower
get utrancell=DXU0040 hoType
get utrancell=cnu1970 adminis (gives unlocked)
get utrancell=cnu1970 cellreserve (gived reserved)
get UTRANcell=cnu1970 qrxlevmin|usedFreqThresh2dEcno|sIntersearch|cpich|usedFreq
Thresh2dRscp|MaximumTransmissionPower (counters can ce clubbed, can check any po
ssible counters)
lki (will show consistent and in-consistent Iub links all)
h lki (help on lki)
str | grep DXU5850A (Shows the status of the cell DXU5850A)
get utrancell=HXU0470 scr (scrambling code)
Pmx -m 2 aal2ap=b265 pmUnSuccOutConnsRemoteQosClass (getting Iub congestion -rem
ote last 2 hours)
get PRSJU0033 rbsid (gives the bnum of the site)
get utrancell=PRSJU0010 (gives al information about the cell)
lget utrancell=TXV42374 directedretry
hget utrancell=HXU4921 Administrativestate|operationalstate|cellreserved
hget .HXV2921 localCellId|dlCodeAdm|pwrAdm
rbs: lgo
rnc: lgo | grep ####
get HXU0182 pwradm|pwroffset|dlcodeadm|compmodeadm|sf
hget HXV2921 maximumTransmissionPower|cpich|minpwrRL|minpwrmax|primaryCpichPower
cedr | grep####
cedh | grep2637
s+ : apply this cmd before any relations cmd to get the relations in desending o
rder.
amos -v corba_class=5,nm_credential=/home/v94868/Ericsson/OMSec/ssucredentials.x
ml SNANTX78CRBR10
to check ROP
pmx utrancell=TXU0275 pmtotnorrcconnect(req$|reqsuccess)|pmNoRabEstablishSuccess
Speech|pmNoRabEstablishAttemptSpeech -m 0.25 -a
pmx TXU0237|TXV4237 pmnosystemrabreleasespeech|pmNoSysRelSpeechSoHo|pmNoSysRelSp
eechNeighbr|pmNoSysRelSpeechUlSynch -m 0.25 -a
pmx -m 2 cell=TXU61188 pmCellDowntime -to check downtime

lget . defaulthotype
pmom . counter name
mom . Cpich ()
llog(restart info)
lhsh 000100 te log read | grep -i err
lhsh 000100 te log read | grep error

lhsh 000100 te log read | grep synchronizationFailure


pmxh . pmCapAllocIubHsLimitingRatioSpi03|pmHsDataFramesLostSpi03 -m 5-Transport
issues

pmx UtranCell=HXU2531 pmNoFailedAfterAdm -m 48 -a (Failed after admission)


get . outputpower
get externalTMA
lget utrancell=HXU4182 hsiflsmarginusers|hsiflsthreshusers|iflsmode|pathlossthre
shold
lget coveragerelation ref
lget utrancell=HXU25551 coveragerelation
get UtranCell=HXU25551,CoverageRelation
lh rax ter 3600
lh tx ter 3600
external defined or not
AUSUTXNIRNC003> lget HXV43777 external
RL attempts from OSS
pmx UtranCell=HXU0043 pmRlAddAttemptsBestCellSpeech -m 240

Hardware:
Main RBS Cabinet for macrocells contains: FU, RU, RUIF
for drpdue to others
board errors
CBU errors
RSSI
overshooting
pilot pollution in the area
vswr
transport issues
SC collision
IFHO failures
Neighboring sites with alarms or cell down time

HSIFLS
this iflsmode will tell that when to trigger eaither 0=rar_est 1=Upswitch_att, 2
=Rab_est_or_upswitch_att
hsIflsThreshUsers

First inter-frequency load sharing candidate cells must be defined, by defining


coverage relations and setting the hsLoadSharing and/or dchLoadSharing attribute
s to ON. HSDPA load sharing can then be activated by setting hsIflsThreshUsers t
o a value other than 0. Non-HSPA load sharing can then be activated by setting d
chIflsThreshPower and/or dchIflsThreshCode to a values other than 0.
this is what i under shood i am sharing to you
if we are keep 0 thenif power congestion ifls will not trigger
if you are keeping cod as 0 the n also it will not trigger
it will trigger only wehn you are keep 50
ok i will try for i cell & share

NON HS
ok so you have total power and than you have power used each cell for cs traffic
. the ideally is to keep that power as low as possible. and whateever the power
used on cs traffic rest are for the hs. the graph that shows the power utilizati
on for yoru cs are called the non-hs power utilization
you look into this to make judgement if you cell is heavily congested or not. if
it is not than you can cahnge your admission parameters cause many cases they a
re set to very high

Date: 2013-07-19
Object
UtranCell=HXU52511
UtranCell=HXU52511
UtranCell=HXU52512
UtranCell=HXU52512
UtranCell=HXU52513
UtranCell=HXU52513
UtranCell=HXU52514
UtranCell=HXU52514
UtranCell=HXU52515
UtranCell=HXU52515
UtranCell=HXU52516
UtranCell=HXU52516
UtranCell=HXU5251A
UtranCell=HXU5251A
UtranCell=HXU5251B
UtranCell=HXU5251B
UtranCell=HXU5251C
UtranCell=HXU5251C
UtranCell=HXV62511
UtranCell=HXV62511
UtranCell=HXV62512
UtranCell=HXV62512
UtranCell=HXV62513
UtranCell=HXV62513

Counter
15:00 16:00 17:00
pmNoFailedRabEstAttemptLackDlHw
0
0
0
pmNoFailedRabEstAttemptLackDlHwBest
0
0
0
pmNoFailedRabEstAttemptLackDlHw
0
0
0
pmNoFailedRabEstAttemptLackDlHwBest
0
0
0
pmNoFailedRabEstAttemptLackDlHw
0
0
0
pmNoFailedRabEstAttemptLackDlHwBest
0
0
0
pmNoFailedRabEstAttemptLackDlHw
10
6
0
pmNoFailedRabEstAttemptLackDlHwBest
8
6
0
pmNoFailedRabEstAttemptLackDlHw
56
27
0
pmNoFailedRabEstAttemptLackDlHwBest
46
12
0
pmNoFailedRabEstAttemptLackDlHw
0
0
0
pmNoFailedRabEstAttemptLackDlHwBest
0
0
0
pmNoFailedRabEstAttemptLackDlHw
0
0
0
pmNoFailedRabEstAttemptLackDlHwBest
0
0
0
pmNoFailedRabEstAttemptLackDlHw
0
0
0
pmNoFailedRabEstAttemptLackDlHwBest
0
0
0
pmNoFailedRabEstAttemptLackDlHw
0
0
0
pmNoFailedRabEstAttemptLackDlHwBest
0
0
0
pmNoFailedRabEstAttemptLackDlHw
9
6
0
pmNoFailedRabEstAttemptLackDlHwBest
9
8
0
pmNoFailedRabEstAttemptLackDlHw
15
36
0
pmNoFailedRabEstAttemptLackDlHwBest
14
32
0
pmNoFailedRabEstAttemptLackDlHw
8
6
0
pmNoFailedRabEstAttemptLackDlHwBest
6
6

********************************************************************************
****************************************************
UtranCell hsdschInactivityTimerCpc long
--------------------------------------------------------------------------------

---------------------------------------------------Time after which a CPC activated connection with low throughput is downswitched
from CELL_DCH to CELL_FACH. This parameter is used instead of hsdschInactivityTi
mer for CPC activated connections.
Special value
-1: corresponding parameter on MOC ChannelSwitching is used
Resolution: 5
Dependencies: Used if the feature InactivityTimerCellConfig is activated and if
the parameter value is defined. If not the corresponding parameter on MOC Channe
lSwitching is used.
Feature: InactivityTimerCellConfig
Change takes effect: New connections
Unit: 0.1 s
Range: -1, 0 to 1000, Default=-1
********************************************************************************
****************************************************
********************************************************************************
****************************************************
UtranCell hsdschInactivityTimer long
----------------------------------------------------------------------------------------------------------------------------------Time after which a connection with low throughput is downswitched from HS-DSCH t
o CELL_FACH.
Once the throughput on both the uplink and downlink has fallen below the value o
f ChannelSwitching::downswitchTimerThreshold, a downswitch to FACH/RACH is norma
lly requested after this length of time. However, the downswitch is not requeste
d if the throughput has subsequently increased above the value of ChannelSwitchi
ng::downswitchTimerThreshold. If CELL_FACH state is not available, the connectio
n is switched down to IDLE state. Applicable only for radio connections without
CPC.
Special values:
-1: corresponding parameter on MOC ChannelSwitching is used
7200: only for internal use.
Dependencies: Used if the feature InactivityTimerCellConfig is activated and if
the parameter value is <> -1. If not the corresponding parameter on MOC ChannelS
witching is used.
Feature: InactivityTimerCellConfig
Change takes effect: New connections
Unit: s
Range: -1, 1 to 255, 7200, Default=-1
********************************************************************************
****************************************************

for parameters
mom MO parametername
for counters
pmom MO countername
HOW TO MOBATCH
mobatch sitelist.txt 'lt all;get . rbslocalcell; get . localcellid;get . maxDlPo
werCapability' Parameters
in some cases when you need something but that parameter needs pass (like cabx)
you need to add a password in the sitelist

CVU2066
CNU6108
CVU0407
CVU4366

password=rbs2066
password=rbs6108
password=rbs0407
password=rbs4366

egrep -i (optional) 'maxdl|localcellid|rbs' ./*.log > dump.txt


for multiple lookups in Parameter CR
VLOOKUP(B2,Sheet1!A:V,MATCH(D2,Sheet1!A$1:V$1,0),0)

lgaes -s 20130901-alarms,event,crashes
llog
lgd-downtime
st t1
pmr -m 3 -r 25-report no 25 to show the packetloss
lh rax te log read | grep -i error-RAX check
lh tx te log read | grep -i error-Tx Check
s+

For 1900, check if its -120/ -8


For 850, if its -95/-8
This usually helps the PS ACC..
HW/SW load
MOC
Parameter
AT&T Gold Standard
Initial Value
(Only to be used by Ericsson when building a new site)
W12B
Eul=1900
pathlossThresholdEulTti2
95..170 120
W12B
Eul=850 pathlossThresholdEulTti2
95..170 95
W12B
Eul
threshEulTti2Ecno
-8

AAL2 BO
Jose Alberto Grimaldo 4:30 PM
ok, this report show you of course if you site have ATM transport
if you have congestion issues in the transport part
every QosClass have some resources assigned for voice, video, data
Mohammed Mohiuddin 4:31 PM
ok
Jose Alberto Grimaldo 4:32 PM
and with this report you can see the number of success in every class
and how many are unsuccess

amos -v corba_class=5,nm_credential=/home/v46248C/Ericsson/OMSec/ssucredentials.
xml,secure_shell=1,secure_ftp=1,username=eeidhd OKCYOKMTCRBR12

hget SXU0048|SXV0548 qrxlevmin|primarycpich|uarfcndl|hsiflsthresh|sf8Adm$|dlcode


adm|sf16Adm$|pwradm|pwroffset|individual|dchiflsthresh|admin

mobatch -v corba_class=5,nm_credential=/home/v94868/Ericsson/OMSec/ssucredential
s.xml AUSSTXBWRNC002,AUSUTXNICRBR11,AUSUTXNICRBR12,AUSUTXNICRBR13,AUSUTXNICRBR15
,AUSUTXNICRBR17,AUSUTXNICRBR18, 'lt utranrelation;lget . frequencyrelationtype 0
' AUS_1002
mobatch HSTNTX01CR0R14,HSTNTXM2RNC003,HSTNTXM2RNC001,HSTNTX01CRBR21, 'lt utranre
lation;lget . frequencyrelationtype 0' intra_0927
mobatch sitelist.txt 'lt all; st cell; other cmds; q' outputfolder

v94868@all2e2cx2>
v94868@all2e2cx2>
v94868@all2e2cx2>
v94868@all2e2cx2>

cd AUS_1002
grep UtranCell ./*.log > AUS_1002.txt
gzip AUS_1002.txt
pwd

pmx HXU5216|HXV6216 pmOutHsIflsHhoAtt|pmOutHsIflsHhoSucc -m 2


for Eutranfreq- get HXU2547.*,eutranfreqrelation Id