Sei sulla pagina 1di 12

Tube Probe Selection Guide version 3.

0
MultiScan MS5800 tube inspection: Internal probes
Welcome to the Tube Probe Selection Guide program... Version 3.0!
This tool is intended to assist our distinguished customers and representatives with the probe selection process. This guide recommends standard probes exclusively. If
no probe recommendation is provided, your specifications may require a custom probe design. If so, please contact us for feasibility and evaluation.
The information contained in this guide was carefully revised in compliance with the latest "Probe and Accessories" catalog.
http://www.olympus-ims.com/en/tube-inspection-probes/
We invite you to download this catalog at the following
address:
This guide is best viewed with a screen resolution of 1600 X 900. However, the zoom can be used for a quick fit-to-screen adjustment.

Faster is Better - Generally Available for Immediate Delivery!


The main new features included in the 3.0 version are based on recommendations from our most valuable customers. Because short delivery times are very important
to most of our customers, the 3.0 selection guide now recommends probes that are available off the shelf. Use the probe parameters to locate regularly stocked
probes.
We invite you to browse each page of this guide and to select ECT, RFT, NFT, MFL, and IRIS probes by clicking on the various tabs at the bottom of your screen. For
details, see the page summaries below:
ECT, RFT, NFT, & MFL: This page recommends the best suitable electromagnetic technology probe from a large selection of probe models tailored to your needs,
based on your tube dimensions and material.
MULTIPLE ENTRY: Use this form to generate multiple ECT, RFT, NFT, and MFL probe lists from a selection of tubes.
PROBE FINDER: Enter the required probe specifications: part number and description will automatically populate if the probe is available. Regularly stocked probes
are also displayed with their corresponding U8 ordering number.
ECT F90: This frequency calculation tool is used to calculate the optimal frequency (called "F90") based on material properties such as resistivity, conductivity, and
magnetic permeability.
IRIS: This page provides recommendations for probe components needed to perform IRIS inspections. However, an IRIS system is not complete without accessories
such as pumps, filters, units, cables, etc. See the catalog for more information.
Tools: This page provides tools to help you calculate tube dimensions and convert units.
Please feel free to contact us at any time for assistance with your application. We hope you enjoy this guide!
http://www.olympus-ims.com
Version 3.0 - Released November 11th, 2011

Selection tool for ECT, RFT, NFT, & MFL probes


MultiScan MS5800 tube inspection: Internal probes

##

Diameter (opt for ID if

Enter the tube dimensions

OD (Outside Diameter)

the actual value is known) 0.750

Inches

Wall thickness (WT)

BWG

Fill Factor (FF) [%]

16.000

Specified custom fill factor


Specify ->

86.0%

ID (Inside Diameter)

0.620

Inches

OD-finned

choix units DIA


##

Choix units WT
##

Actual Fill Factor

88.3%
OD-finned?

Select the tube material

Choix Fill factor

Brass (70/30 Cu-ZN)

(Used to calculate probe center frequency. If you do not see the material in the list, please consult the "ECT F90" page.)

Confirm the probe series

TEA - ECT Bobbin probe, attached

Select the cable type and length


(Fixed models only)

Find regularly stocked probes!

N - Standard Nylon

##

Matriel slectio

###

20 m (65 ft.)

Part number

Description

TEA-148-005-N20

ECT Bobbin probe, 14.8 mm (0.583 in.), 5 kHz center frequency, 20-m (65.6
ft.) cable.

Faster is Better - Generally Available for Immediate Delivery - U8280616

Probe series
##
TEA
TED
TEE
TEF
TEG

Version 3.0 - Released November 11th, 2011

##

###

Multiple entry for ECT, RFT, NFT & MFL probes

MultiScan MS5800 tube inspection: internal probes

Instructions:
1) Complete the TUBE parameter and PROBE data fields (please refer to the "Probe and Accessories catalog" for more information about probes).
2) Do not modify the yellow, blue, or comment cells because they contain formulas.
3) Copy the cell contents and paste them into a new Excel worksheet using the "Values only" paste option.
Tip: Drag the mouse over the column headers to view pop-up information.

1 Enter the TUBE parameters

2 Select the

3 Read or copy the automatic probe INFORMATION

PROBE data
No
Units
.

OD /
ID

Wall
Missin Force a
Fill
Thicknes
OD
Value Thicknes
g
fill
Factor
s
finned?
s
ID/OD factor?
(%)

inches

ID

1.00

specify
->

0.040

Yes

OD is
1.08
inches

No

inches

OD

0.75

BWG 18

0.080

No

ID is
0.65
inches

No

mm

OD

27.00

specify
->

2.600

ID is
21.8
mm

Yes

mm

OD

27.00

specify
->

2.600

inches

ID

2.50

BWG 9

mm

OD

25.40

specify
->

2.770

inches

OD

0.75

specify
->

0.070

inches

OD

0.75

BWG 21

inches

OD

1.00

specify
->

0.080

Yes

Real Fill
factor

Material

Model

Cable

Probe Part
Number

Probe Description

Comment/Stock probe

Real Fill
Factor is
89%

Brass (70/30 Cu-ZN)

TEA

N20 TEA-240-015-N20

ECT Bobbin probe, 24 mm (0.945 in.), 15


kHz center frequency, 20 m (65.6 ft.) cable.

Know fin material - please contact specialist.

Real Fill
Factor is
91%

Stainless Steel 304 - A213 TP304, A249 TP304, A688 TP304

TEB

N20

TEB-158-250

ECT Bobbin probe, detachable, 15.8 mm (0.622


in.), 250 kHz center frequency.

#REF!

Real Fill
Factor is
76%

Carbon steel - A178, A179, A192, A210, A214

TRS

N20

TRS-190-300-N20

RFT Single Exciter probe, 19 mm (0.748 in.), 300


Hz center frequency, 20 m (65.6 ft.) cable.

#REF!

ID is
21.8
mm

Real Fill
Factor is
76%

Carbon steel - A556

TRS

N20 TRS-190-02K-N20

RFT Single Exciter probe, 19 mm (0.748 in.),


2 kHz center frequency, 20 m (65.6 ft.)
cable.

#REF!

OD is
2.8
inches

Real Fill
Factor is
75%

Carbon steel - A178, A179, A192, A210, A214

TRC

N20 TRC-550-300-N20

RFT Boiler (flexible) probe, 55 mm (2.165


in.), 300 Hz center frequency, 20 m (65.6 ft.) #REF!
cable.

ID is
19.86
mm

Real Fill
Factor is
81%

Carbon steel - A178, A179, A192, A210, A214

TFB

N20

MFL High-Saturation probe, 17.9 mm (0.705 in.),


20 m (65.6 ft.) cable.

#REF!

ID is
0.61
inches

Real Fill
Factor is
70%

Stainless Steel Duplex (2205), 3RE60 - A789

TRS

N20 TRS-130-15K-N20

RFT Single Exciter probe, 13 mm (0.512 in.),


15 kHz center frequency, 20 m (65.6 ft.)
cable.

#REF!

ID is
0.69
inches

Real Fill
Factor is
86%

Brass (Admiralty) - SB111, SB543

TEA

N20

TEA-162-050-N20

ECT Bobbin probe, 16.2 mm (0.638 in.), 50 kHz


center frequency, 20 m (65.6 ft.) cable.

#REF!

ID is
0.84
inches

Real Fill
Factor is
77%

Carbon steel - A178, A179, A192, A210, A214

TFB

N20

TFB-187-N20

MFL High-Saturation probe, 18.7 mm (0.736 in.),


20 m (65.6 ft.) cable.

#REF!

88%

80%

TFB-179-N20

10

11

12

13

14

15

16

17

18

19

Version 3.0 - Released September 19th, 2011

Page 3/12

Multiple entry for ECT, RFT, NFT & MFL probes

MultiScan MS5800 tube inspection: internal probes

Instructions:
1) Complete the TUBE parameter and PROBE data fields (please refer to the "Probe and Accessories catalog" for more information about probes).
2) Do not modify the yellow, blue, or comment cells because they contain formulas.
3) Copy the cell contents and paste them into a new Excel worksheet using the "Values only" paste option.
Tip: Drag the mouse over the column headers to view pop-up information.

1 Enter the TUBE parameters

2 Select the

3 Read or copy the automatic probe INFORMATION

PROBE data
No
Units
.

OD /
ID

Wall
Missin Force a
Fill
Thicknes
OD
Value Thicknes
g
fill
Factor
s
finned?
s
ID/OD factor?
(%)

Real Fill
factor

Material

Model

Cable

Probe Part
Number

Probe Description

Comment/Stock probe

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

Version 3.0 - Released September 19th, 2011

Page 4/12

Multiple entry for ECT, RFT, NFT & MFL probes

MultiScan MS5800 tube inspection: internal probes

Instructions:
1) Complete the TUBE parameter and PROBE data fields (please refer to the "Probe and Accessories catalog" for more information about probes).
2) Do not modify the yellow, blue, or comment cells because they contain formulas.
3) Copy the cell contents and paste them into a new Excel worksheet using the "Values only" paste option.
Tip: Drag the mouse over the column headers to view pop-up information.

1 Enter the TUBE parameters

2 Select the

3 Read or copy the automatic probe INFORMATION

PROBE data
No
Units
.

OD /
ID

Wall
Missin Force a
Fill
Thicknes
OD
Value Thicknes
g
fill
Factor
s
finned?
s
ID/OD factor?
(%)

Real Fill
factor

Material

Model

Cable

Probe Part
Number

Probe Description

Comment/Stock probe

39

40

41

42

43

44

45

46

47

48

49

50

51

52

53

54

55

56

57

Version 3.0 - Released September 19th, 2011

Page 5/12

Multiple entry for ECT, RFT, NFT & MFL probes

MultiScan MS5800 tube inspection: internal probes

Instructions:
1) Complete the TUBE parameter and PROBE data fields (please refer to the "Probe and Accessories catalog" for more information about probes).
2) Do not modify the yellow, blue, or comment cells because they contain formulas.
3) Copy the cell contents and paste them into a new Excel worksheet using the "Values only" paste option.
Tip: Drag the mouse over the column headers to view pop-up information.

1 Enter the TUBE parameters

2 Select the

3 Read or copy the automatic probe INFORMATION

PROBE data
No
Units
.

OD /
ID

Wall
Missin Force a
Fill
Thicknes
OD
Value Thicknes
g
fill
Factor
s
finned?
s
ID/OD factor?
(%)

Real Fill
factor

Material

Model

Cable

Probe Part
Number

Probe Description

Comment/Stock probe

58

59

60

61

62

63

64

65

66

67

68

69

70

71

72

73

74

75

76

Version 3.0 - Released September 19th, 2011

Page 6/12

Multiple entry for ECT, RFT, NFT & MFL probes

MultiScan MS5800 tube inspection: internal probes

Instructions:
1) Complete the TUBE parameter and PROBE data fields (please refer to the "Probe and Accessories catalog" for more information about probes).
2) Do not modify the yellow, blue, or comment cells because they contain formulas.
3) Copy the cell contents and paste them into a new Excel worksheet using the "Values only" paste option.
Tip: Drag the mouse over the column headers to view pop-up information.

1 Enter the TUBE parameters

2 Select the

3 Read or copy the automatic probe INFORMATION

PROBE data
No
Units
.

OD /
ID

Wall
Missin Force a
Fill
Thicknes
OD
Value Thicknes
g
fill
Factor
s
finned?
s
ID/OD factor?
(%)

Real Fill
factor

Material

Model

Cable

Probe Part
Number

Probe Description

Comment/Stock probe

77

78

79

80

81

82

83

84

85

86

87

88

89

90

91

92

93

94

95

Version 3.0 - Released September 19th, 2011

Page 7/12

Multiple entry for ECT, RFT, NFT & MFL probes

MultiScan MS5800 tube inspection: internal probes

Instructions:
1) Complete the TUBE parameter and PROBE data fields (please refer to the "Probe and Accessories catalog" for more information about probes).
2) Do not modify the yellow, blue, or comment cells because they contain formulas.
3) Copy the cell contents and paste them into a new Excel worksheet using the "Values only" paste option.
Tip: Drag the mouse over the column headers to view pop-up information.

1 Enter the TUBE parameters

2 Select the

3 Read or copy the automatic probe INFORMATION

PROBE data
No
Units
.

OD /
ID

Wall
Missin Force a
Fill
Thicknes
OD
Value Thicknes
g
fill
Factor
s
finned?
s
ID/OD factor?
(%)

Real Fill
factor

Material

Model

Cable

Probe Part
Number

Probe Description

Comment/Stock probe

96

97

98

99

100

Version 3.0 - Released November 11th, 2011

Version 3.0 - Released September 19th, 2011

Page 8/12

Probe Finder for ECT, RFT, NFT & MFL probes


MultiScan MS5800 tube inspection: internal probes

Look for Regularly Stocked ECT Alternatives

1 Select the PROBE specifications

2 Read or copy the automatic probe INFORMATION

Probe Dia.
No.

Model

(mm x 10,
0.2mm rounded down.
145 = 14.4 mm)

Freq.

Cable

Probe Part Number

Probe Description

Comment/Stock probe

TEA

146

050

N15

TEA-148-050-N20

ECT Bobbin probe, 14.8 mm (0.583 in.), 50 kHz center


frequency, 20-m (65.6 ft.) cable.

#REF!

TEA

146

050

N20

TEA-148-050-N20

ECT Bobbin probe, 14.8 mm (0.583 in.), 50 kHz center


frequency, 20-m (65.6 ft.) cable.

#REF!

TFB

188

N20

TFB-187-N20

MFL High-Saturation probe, 18.7 mm (0.736 in.), 20-m


(65.6 ft.) cable.

#REF!

TEO

222

050

N20

TEO-222-050-N20

ECT CARTER Super Magnetic probe, 22.2 mm


(0.874 in.), 50 kHz center frequency, 20-m (65.6
ft.) cable.

#REF!

TED

149

050

TED-148-050

ECT Air conditioner probe, detachable, 14.8 mm


(0.583 in.), 50 kHz center frequency.

#REF!

10

11

12

<

Version 3.0 - Released November 11th, 2011

Page 9 / 12

ECT-frequency calculation tool


MultiScan MS5800 tube inspection: Internal probes
Result

F90 = 3

F90 is the optimal (center) frequency (kHz)

is the electrical resistivity (cm)


t is the tube thickness (mm)

t
2

is the relative permeability (dimensionless)

Resistivity/Conductivity
Wall Thickness
Relative Permeability

F90 frequency:
F180 Prime frequency:

Version 3.0 - Released November 11th, 2011

F90 =
F180 =

2.50E+01
0.800

mm

1.0

32.3
64.5

% I.A.C.S. (resistivity)

kHz
kHz

###
###
Result

Selection tool for IRIS probe components


MultiScan MS5800 tube inspection: Internal probes

Enter the tube dimensio

Diameter (opt for ID if


the actual value is known)

OD (Outside Diameter)

25.400

mm

Wall thickness (WT)

12.000

BWG

OD-finned

Bends

Swages

Select the probe components


Show.

Part number

Description

Turbine (TUA)

TUA-170

17.0 mm (0.67") IRIS turbine

Transducer (TUB)

TUB-254-15M

15 MHz, 25.4 mm (1.0") focal length IRIS immersion


transducer

Centering device (TUC)

TUC-SM

Small IRIS centering device, 18.0 mm to 25.4 mm


(0.71 to 1.00)

Probe cable (TUD)


20 m (65.6 ft.) - Standard length

Version 3.0 - Released November 11th, 2011

Tube dimension tools


MultiScan MS5800 tube inspection: Internal probes

BWG (Birmingham Wire Gage) tube thickness chart


BWG
2
3
4
5
6
7
8
9
10
11
12
13

Wall thickness
mm
inches
7.21
0.284
6.58
0.259
6.05
0.238
5.59
0.220
5.16
0.203
4.57
0.180
4.19
0.165
3.76
0.148
3.40
0.134
3.05
0.120
2.77
0.109
2.41
0.095

Version 3.0 - Released November 11th, 2011

BWG
14
15
16
17
18
19
20
21
22
23
24

Wall thickness
mm
inches
2.11
0.083
1.83
0.072
1.65
0.065
1.47
0.058
1.24
0.049
1.07
0.042
0.89
0.035
0.81
0.032
0.71
0.028
0.64
0.025
0.56
0.022

Inches vs. mm converter


1.00 mm
1.000 in.

0.039 in.
25.40 mm

Feet vs. meter converter


1.00 m

3.28 ft.

1.000 ft.

0.30 m

Potrebbero piacerti anche