ROOF SOLUTIONS
TRUS JOIST
18" and 20"
TJI 360 TJI 560
JOISTS
www.iLevel.com
1.888.iLevel8 (1.888.453.8358)
ALL IN ONE
WELCOME TO iLEVEL
iLevel is an exciting new brand and business within Weyerhaeuser.
iLevel brings the most innovative and trusted products for
residential construction together under one roof. Within iLevel, youll
still nd all the reliable, brand-name building products that youve
been usingTrus Joist engineered wood products and design
software, Structurwood engineered panels, Framer's Series
lumber, and more. But with iLevel, youll work with only one
service-oriented supplier to get all of these products and the
support you need to build smarter.
iLevel. A family of brand-name building products
a source for innovative ideas and solutions
a supplier thats simpler to do business with.
TABLE OF CONTENTS
3
3
4
4
5
67
89
10
11
May 2008
Depth
2516"
18"
20"
138"
TJI
360
560
360
560
38"
18"
20"
Depth
18"
20"
TJI
360
560
360
560
(1) Web stiffeners are required at intermediate supports of continuous-span joists when the intermediate bearing length is less than
5" and the span on either side of the intermediate bearing is greater than the following spans:
TJI
312"
360
560
138"
716"
18"
20"
Long term deflection under dead load, which includes the effect of creep, has not been considered. Bold italic spans reflect initial
dead load deflection exceeding 0.33".
General Notes
DESIGN PROPERTIES
Design Properties (100% Load Duration)
Basic Properties
Depth
18"
20"
TJI
360
560
360
560
Joist
Weight
(lbs/ft)
Maximum
Resistive
Moment (1)
(ft-lbs)
Joist Only
El x 10 6
(lbs-in. 2)
Maximum
Vertical
Shear (lbs)
1"
End
Reaction
(lbs)
3.7
4.8
4.0
5.1
9,465
14,550
10,515
16,165
1,085
1,631
1,376
2,064
2,425
3,030
2,660
3,345
1,080
1,265
1,080
1,265
Reaction Properties
3" Intermediate
Reaction (lbs)
No Web
With Web
Stiffeners
Stiffeners
2,460
2,815
3,000
3,475
2,460
2,815
3,000
3,475
(1) Caution: Do not increase joist moment design properties by a repetitive-member-use factor.
General Notes
Design reaction includes all loads on the joist. Design shear is computed at
the inside face of supports and includes all loads on the span(s). Allowable
shear may sometimes be increased at interior supports in accordance with
ICC ES ESR-1153, and these increases are reected in span tables.
w
L
d
El
=
=
=
=
May 2008
Customer Satisfaction
84%
63%
96% 99.9%
45 points? 84% nd it
good to excellent and
16% nd it marginal to
unacceptable.
28%
Good
Better
Excellent
ALLOWABLE HOLES
Minimum distance from Table B
6"
6"
D1
2 x D1
minimum
(applies to all holes
except knockouts)
L2
L1
2 x L2 D
2
minimum
6"
6"
Minimum distance from edge of hole to inside face of nearest end support
Depth
18"
20"
TJI
360
560
360
560
4"
1'-0"
1'-0"
1'-0"
1'-0"
5"
1'-0"
1'-0"
1'-0"
1'-0"
6"
1'-0"
1'-0"
1'-0"
1'-0"
12"
5'-0"
5'-0"
2'-0"
1'-0"
15"
17"
10'-0"
11'-0"
7'-0" 10'-6"
7'-0" 11'-0"
4"
1'-0"
1'-0"
1'-0"
1'-0"
5"
1'-0"
1'-0"
1'-0"
1'-0"
15"
17"
13'-6"
14'-6"
14'-0" 15'-6"
14'-6" 15'-6"
TJI
360
560
360
560
4"
1'-0"
1'-0"
1'-0"
1'-0"
5"
1'-0"
1'-0"
1'-0"
1'-0"
6"
1'-0"
1'-0"
1'-0"
1'-0"
12"
9'-0"
10'-0"
6'-0"
5'-6"
15"
17"
15'-0"
16'-6"
11'-0" 15'-6"
12'-0" 16'-0"
4"
1'-0"
1'-0"
1'-0"
1'-0"
5"
1'-6"
3'-6"
1'-0"
1'-0"
15"
17"
19'-6"
20'-0"
19'-0" 21'-0"
19'-6" 20'-6"
DO NOT
cut or notch ange.
General Notes
4. Maintain the required minimum distance from the end and the
intermediate or cantilever support.
18"
May 2008
DO NOT
cut holes in cantilever
reinforcement.
Structural sheathing
Protect untreated wood
from direct contact
with concrete
112" knockouts
at approximately
12" on-center
WARNING
DO NOT walk on joists until braced.
INJURY MAY RESULT.
Joists are
unstable
until braced
laterally
Bracing Includes:
Blocking
Hangers
Rim Board
Sheathing
Rim Joist
Strut Lines
WARNING
Joists are unstable until
laterally braced.
See Warning Notes below.
WARNING NOTES:
1. All blocking, hangers, rim boards, and rim joists at the end supports of the TJI
joists must be completely installed and properly nailed.
2. Lateral strength, like a braced end wall or an existing deck, must be established at
the ends of the bay. This can also be accomplished by a temporary or permanent
deck (sheathing) fastened to the rst 4 feet of joists at the end of the bay.
3. Safety bracing of 1x4 (minimum) must be nailed to a braced end wall or sheathed
area (as in note 2) and to each joist. Without this bracing, buckling sideways or
rollover is highly probable under light construction loadssuch as a worker or one
layer of unnailed sheathing.
4. Sheathing must be completely attached to each TJI joist before additional loads
can be placed on the system.
5. Ends of cantilevers require safety bracing on both the top and bottom anges.
6. The anges must remain straight within a tolerance of 12" from true alignment.
May 2008
FLOOR DETAILS
Load bearing or shear wall above
(must stack over wall below)
Intermediate Bearing
No Load Bearing Wall Above
2x4 minimum
squash blocks
116"
B1
B1
W
B2
B3
W
B3
Apply suboor
adhesive to all
contact surfaces
Top flange
hanger
Face mount
hanger
Directly applied ceiling
H3
Two 8d (0.113"
x 212") box nails
or 212" screws,
typical
TJI
Depth
Filler Block(1)
(Detail H2)
Backer
(Detail F1
or H2)
360
18" or 20"
2x12 + "
sheathing
560
18" or 20"
1" net
2x12
Two 2x12
Block(1)
2x4 minimum
squash blocks
CS
116"
4"(2)
4"
6"
6"(3)
General Notes
Equivalent
Nominal
Framing Width
Maximum
Capacity
(plf)
3"
720
(1) One row of fasteners permitted (two at abutting panel edges) for diaphragms. Stagger nails when using 4" on-center
spacing and maintain 38" joist and panel edge distance. For other applications, multiple rows of fasteners are permitted
if the rows are offset at least " and staggered.
(2) Can be reduced to 3" on-center for light gauge steel straps with 10d (0.148" x 1") nails.
(3) Can be reduced to 4" on-center with maximum nail penetration of 138" into the narrow edge.
May 2008
FLOOR DETAILS
Blocking
panel
Flashing
A1
Treated
2x_ ledger
See fasteners below.
Maintain 2" distance
(minimum) from edge of
ledger to fastener.
Fastener
3 8"
lag bolt
1 2 " lag bolt
LA
A2
One 8d (0.113"
x 2") nail each
side. Drive nails
at an angle at
least 1" from
end.
LSL
rim board
TimberStrand
18"
1"
1"
1" minimum bearing
at end support; 3" minimum
at intermediate support
Tight
112"
TJI 560
floor joist
114" TimberStrand LSL
rim board:
One 10d (0.128" x 3") nail
into each flange
TJI 360 rim joist:
One 16d (0.135" x 3")
nail into each flange
1" minimum
bearing
Gap:
18" minimum
234" maximum
112"
2x4 web
stiffener(2)
Tight
TJI 560
rim joist
May 2008
CANTILEVERS
Cantilevers Less Than 5" (Brick Ledge)
2'-0"
2'-0"
L1
Less than 5"
L1
5" to 24"
Web stiffeners
required at E1W
4"
5"
to 2
F1
es
tim ngth
e
1
er l
ilev
t
n
ca
1 2
ver
tile
n
a
C ngth
le -0"
4' mum only)
s
xi
ma load
m
r
o
if
(un
Wood backer
Blocking panel between each joist.
Nail with connections equivalent to
floor panel schedule.
May 2008
CANTILEVERS
Cantilever Reinforcement
Section A: Cantilevers less than 5" (Brick Ledge)
Depth
TJI
Roof
Truss
Span
35 PSF
16"
18"
or
20"
360
18"
or
20"
560
24'
26'
28'
30'
32'
34'
36'
38'
40'
24'
26'
28'
30'
32'
34'
36'
38'
40'
19.2"
X
X
X
X
X
X
X
X
24"
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
55 PSF
TJI
19.2"
X
X
X
X
X
X
X
X
X
24"
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
16"
19.2"
E1W
E1W
E1W
E1W
E1W
E1W
E1W
X
X
X
E1W
55 PSF
16"
19.2"
24"
E1W
E1W
E1W
X
E1W
E1W
X
X
X
X
X
X
E1W
E1W
E1W
X
General Notes
For conditions beyond the scope of this table, including cantilevers longer than
24", use our TJ-Beam or TJ-Xpert software.
2. Locate the Roof Truss Span (horizontal) that meets or exceeds your condition.
3. Identify the cantilever condition (less than 5" or 5" to 24") and locate the Roof
Total Load and On-Center Joist Spacing for your application.
4. Scan down to nd the appropriate cantilever detail and refer to drawing on
page 8:
Blank cells indicate that no reinforcement is required.
X indicates that cantilever will not work. Use TJ-Beam or TJ-Xpert software,
or reduce spacing of joists and recheck table.
May 2008
18"
20"
TJI
Live
Load
L/480
360
560
360
560
*
*
*
*
8'
10'
Total
Load
Live
Load
L/480
Total
Load
Live
Load
L/480
320
390
320
390
*
*
*
*
241
294
241
294
*
*
*
*
*
*
*
*
162
197
162
197
*
*
*
*
16'
Live
Load Total
L/480 Load
139
169
139
169
*
*
*
*
121
148
121
148
18"
20"
TJI
360
560
360
560
Live
Load
L/480
*
*
*
*
22'
Total
Load
97
119
97
119
Live
Load
L/480
*
*
*
*
Total
Load
88
108
88
108
81
99
81
99
61
89
*
*
75
91
75
91
28'
Live
Load Total
L/480 Load
30'
Live
Load Total
L/480 Load
72
85
60
79
85
75
79
General Notes
If a live load deection limit of L/360 is desired, multiply value in Live Load
column by 1.33. The resulting live load may not exceed the Total Load shown.
20
25
12"
16"
19.2"
24"
20
27
32
40
25
34
40
50
10
55
60
55
74
88
110
60
80
96
120
May 2008
18'
Live
Load Total
L/480 Load
*
*
*
*
108
132
108
132
Joist
Depth
18"
20"
TJI
Hanger
360
560
360
560
MIT3518
MIT418
MIT3520
MIT420
Nailing
Capacity
(lbs)
Header
Joist
1,265
16d
10d x 1"
1,460
16d
10d x 1"
1,265
16d
10d x 1"
1,460
16d
10d x 1"
Hanger
MIU2.37/18
MIU3.56/18
MIU2.37/20
MIU3.56/20
Nailing
Capacity
(lbs)
Header
Joist
1,265
16d
10d x 1"
1,460
16d
10d x 1"
1,265
16d
10d x 1"
1,460
16d
10d x 1"
Hanger
SUR/L2.37/14
SUR/L414
SUR/L2.37/14
SUR/L414
Joist
Depth
TJI
Hanger
360
560
360
560
LBV4.75/18
B7.12/18
LBV4.75/20
B7.12/20
18"
20"
Nailing
Capacity
(lbs)
Header
Joist
2,460
16d
10d x 1"
2,920
16d
16d
2,460
16d
10d x 1"
2,920
16d
16d
Nailing
Capacity
(lbs)
Header
Joist
1,265
16d
10d x 1"
1,460
16d
10d x 1"
1,265
16d
10d x 1"
1,460
16d
10d x 1"
Hanger
MIU4.75/18
HU414-2
MIU4.75/20
HU414-2
Nailing
Capacity
(lbs)
Header
Joist
2,530
16d
10d x 1"
2,920
16d
16d
2,530
16d
10d x 1"
2,920
16d
16d
Joist
Depth
18"
20"
TJI
Hanger
360
560
360
560
THO23180
THO35180
THO23200
THO35200
Nailing
Capacity
(lbs)
Header
Joist
1,235
10d
10d x 1"
1,430
10d
10d x 1"
1,235
10d
10d x 1"
1,430
10d
10d x 1"
Hanger
THF23180
THF35157
THF23180
THF35157
Nailing
Capacity
(lbs)
Header
Joist
1,265
10d
10d x 1"
1,460
10d
10d x 1"
1,265
10d
10d x 1"
1,460
10d
10d x 1"
Nailing
Capacity
(lbs)
Header
Joist
SKH2324L/R
1,110
10d
10d x 1"
SKH418L/R
1,460
16d
16d
THF23140-SK45L/R 1,265
10d
10d x 1"
SKH418L/R
1,460
16d
16d
Hanger
Joist
Depth
18"
20"
TJI
Hanger
360
560
360
560
THO23180-2
BPH7118
THO23200-2
BPH7120
Nailing
Capacity
(lbs)
Header
Joist
2,770
16d
10d
3,180
16d
10d
2,770
16d
10d
3,180
16d
10d
Hanger
THF23160-2
HD7160
THF23160-2
HD7160
Nailing
Capacity
(lbs)
Header
Joist
2,530
10d
10d
2,920
16d
10d
2,530
10d
10d
2,920
16d
10d
General Notes
Bold italic hangers require web stiffeners.
Capacities will vary with different nailing criteria or other support conditions;
contact your iLevel representative for assistance.
Hanger capacities shown are either joist bearing capacity or hanger capacity
whichever is less. Joist end reaction must be checked to ensure it does not exceed
the capacity shown in the tables.
Use sloped seat hangers and beveled web stiffeners when TJI joist slope
exceeds 14:12.
Leave 116" clearance (18" maximum) between the end of the supported joist and
the header or hanger.
Nails: 16d = 0.162" x 312", 10d = 0.148" x 3", and 10d x 112" = 0.148" x 112".
Support Requirements
Minimum support width for single- and double-joist top mount hangers is 3".
Minimum support width for face mount hangers with 10d and 16d nails is 134"
and 2", respectively.
May 2008
11
ROOF SOLUTIONS
FLOOR SOLUTIONS
CONTACT US
OUR GUARANTEE
1.888.iLevel8 (1.888.453.8358)
www.iLevel.com
iLevel@weyerhaeuser.com
2910 East Amity Road
Boise, ID 83716
208.364.3600
P.O. Box 8449
Boise, ID 83707-2449
May 2008
Reorder TJ-4005
This document supersedes all
previous versions. If this is more
than one year old, contact your
dealer or iLevel rep.
NW
Weyerhaeuser, iLevel, Microllam, Parallam, Silent Floor, Structurwood, Structurwood Edge, Structurwood Edge
Gold, TimberStrand, TJ, TJ-Beam, TJI, TJ-Xpert, and Trus Joist are registered trademarks and All in One and TJ-Pro
are trademarks of Weyerhaeuser. 2008 Weyerhaeuser Company. All rights reserved. Printed in the USA.