Sei sulla pagina 1di 1

C

E
CYCLONE VENTS TO
DETAIL

roof specifications.
it5 sheets roof cover
on steel purlins on steel
portal frames to structural
engineers design and fab
details.

Roof Lvl.

GENERAL
Roof Lvl.

Third Flr. Lvl.

PV
PV

PV

PV

PV

Third Flr. Lvl.

PV

PV

GODOWN 3

permanent ventilation
cut out on wall to
struct eng's detail

Secnd Flr Lvl.

Secnd Flr Lvl.


PV

PV

PV

PV

PV

PV

PV

PV

4,200

CONVAYOR BELT TO
ENG'S DETAIL

GODOWN 2

First Flr. Lvl.

RC COLUMNS TO
STRUCTURAL
ENGINEER'S DETAILS
First Flr. Lvl.

3. All sections are to be read as per floor plan and all drawings must be read in concert
with each other. Any discrepancies must be notified immediately to the architect and
clarified consulting the architectural or consultants drawing.
CONSTRUCTION
4. Damp proof course must be provided under all external walls at grade. DPC to be
minimum 150 mm above ground level.
5. All slab at grade to be poured at 1000 Gauge polythene on 50 mm stone dust
blinding on hardcore.
6. All soil under slab and around external foundations to be poisoned for termite
control.
7. Window sills must be finished before internal plastering.

PV
PV

PV

PV

PV

RC STAIRCASE TO
STRUCT. ENG'S
DETAILS
TREADS - 300
RISERS - 150

PV

Mez. Flr. Lvl.

5,800

PV

1. All measurements are shown in millimeters. Drawings not to be scaled. Only figured
dimensions to be used.
2. The contractor must check and verify all dimensions on site before commencement of
work. Any discrepancies must be notified immediately to the architect.

PV

4,100

PV

N0TES

Mez. Flr. Lvl.

MS GRILL TO
DETAIL

CLIENT
Grnd Flr. Lvl.

Grnd Flr. Lvl.

TECHPACK INDUSTRIES LTD.


SECTIONAL ELEVATION D-D
2

10

11

12

CLIENTS SIGNATURE

01

SECTION A-A

66,100
6,000

200

6,000

35,698

6,000
200

6,150

5,802

5,983

200

5,983

5,983

20,400

200

3,200

200

RWP

200

840

6,000

svp

UP

WC

PV
gt

WC

i.c.

PV

ms grill door
to detail
convayor belt
to detail

OUT

guard

RAMP
i.c.

200

8,250

PV

8,555

waiting

45 saddle conection
to existing sewer line

i.c.

i.c.

ms railing to
detail

8,250

8,250

8,500

DN

ms grill to
detail

LR NO. 12596/116
CULVERT TO
DETAIL

UP
PV

ms grill to
detail

UP

FUTURE
HOIST

change

change

CER. TILES

GENTS

LIFT

LADIES.

ur

WC

WC WC

WC WC

CER.
TILES

CER.
TILES

CER.
TILES

CER.
TILES

CER.
TILES

metal louvred
door to detail

RWP

PV

PV

PV

PV

PV

PV

PV

GENER TOR
ROOM

SWITCH
ROOM

CEM. SCRD FL.

TR NSFORMER
ROOM

CEM. SCRD FL.

PV

PV

CEM. SCRD FL.

PV

PV

CER.
TILES

200
6,000

6,000

2,550

6,000

6,150

42,000

5,883

200

200

200
200 100 100 100 150 100 200 200 200
900 900 900 900 850 850 1,100 1,075 2,000
1,075 200

200

200

200

32,900

GROUND FLOOR PLAN ALT. 1

JULY. 2014

DRAWN BY

G. ODHIAMBO

200

5,983

4,267

200
5,983

24,100

2,500

P.O. Box 14468 - 00800 Nairobi Kenya


Telephone 4180379

RWP

svp

6,000

DATE

Regd Architects

concrete louvred
blocks ventilators
to have expanded
metal internally
with insect gauze.

200

4,500
5,983

200

01

100
150
1,800 1,150
2,500

8,250

6,000

1:200

Satish Shah & Associates

OPEN STORM
WATER DRAIN

EXISTING CCN SEWER LINE

gt

200

PV

6,000

SCALE

200

2,400

3,350

150

200

3,300

4,500

200

svp

8,250

2,550
200

200

SUMP

17,500

1,600

i.c.

200 1,075 200

8,250

6,000

525/1

8,250
i.c.

svp

200

DRG NO.

RAMP

convayor belt
to detail

SUMP

IN

4,975

rc columns to struct.
eng's details

4,500

22,500

33,305

33,440

33,840

GODOWN 1

JOB

PROPOSED DEVELOPMENT
ON PLOT LR. NO. 12956/116,
NAIROBI.

R O A D

6,000

7,000

6,000

100
800
200
200
800
1,600
1,500
200

6,000

COPY RIGHT
THIS

DRAWING IS A COPY RIGHT AND PROPERTY

OF M/S SATISH SHAH & ASSOCIATES, NAIROBI AND


MUST NOT BE COPIED, MADE PUBLIC OR SHOWNTO ANY
OTHER PARTY WITHOUT THEIR WRITTEN PERMISSION