Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
ERRATA
In the Technical Forum article Buckling of Steel Tunnel Liner under
External Pressure by David Berti, Richard Stutzman, Eric Lindquist, and
Maryam Eshghipour, which appeared in December 1998, Vol. 124(3), 55
89, the following clarifications and corrections should be made.
Pcr =
(n 2 1)
Pcr =
t
R
E
12(1 2)
nL
R
t
R
12(1 )
2
R
L
n2
t
R
n2
Et
R
n2 1
nL
R
R
L
n2
2n 2 1
n2
R
L
(8)
(9)
On page 62, the second sentence preceding Eq. (11) should read as follows:
Given that ym is equal to the sum of yo, ys, and yc, substitutions can be made
that eliminate the unknowns ym, ys, yc, and n, leaving Pcr and known values
in the equation.
92
1
42
12
sin
sin
sin
K
sin
tan2( )
1
4
R
12J
F
=0
(13a)
9
1
42
sin
sin
sin
sin
Pcr L cl R 3
=0
E
(13b)
12
92
1
42
sin
sin
sin
K
sin
sin
sin
tan2( )
1
4
R rt = 0
(15a)
92
1
42
Downloaded from ascelibrary.org by 109.224.39.98 on 09/21/13. Copyright ASCE. For personal use only; all rights reserved.
sin
sin
12Pcr R 3rt
=0
E
(15b)
On page 71, at the bottom of the page, Pcr should be 2.030 MPa, not 2,030
MPa:
cr =
w = ave,d
Ro
= (107.88 MPa)
0.003794 m2
1.8794 m
On page 86, Eq. (29) and the equation just below it should read as follows:
w=
R stf
R
Pd
t
A stf,cp
(1 2)1/4
1.52Rt
t
A stf,cp
Pd
(1 2)1/4
1.52Rt
for
R stf
1
R
(29)
where
=1
cos(d ) sin(d )
e d
Pd
t
A stf,cp
1
1.55RT
(30)
1,034 kPa
0.0127 mm
(1 (0.29)2)1/4(1.038)
2
(0.50)(0.003794 m )
1.52(1.8604 m)(0.0127 m)
Downloaded from ascelibrary.org by 109.224.39.98 on 09/21/13. Copyright ASCE. For personal use only; all rights reserved.
w=
1,034 kPa
0.0127 m
1
(0.5)(0.003794 m2)
1.55(1.8604 m)(0.0127 m)