HYUNDAI

MV & LV Circuit Breaker,


Contactor & Overload Relay

MV & LV Circuit Breaker,


Contactor & Overload Relay
Hyundai Circuit Breaker is one of the most reliable
and sophisticated products, which realizes the
optimum design through electric and kinetic analysis.

MCCB

Molded Case Circuit Breaker


up to 1200 A, 130 kA at 415 V

MC

ACB

Magnetic Contactor
up to 800 A

Air Circuit Breaker


up to 6300 A, 120 kA at 500 V

VCB

Vacuum Circuit Breaker


up to 38 kV, 40 kA, 3150 A

We build a better future!

Contents

Molded Case Circuit Breaker | 04


Air Circuit Breaker | 16

Contactor & Overload Relay | 06

Vacuum Circuit Breaker | 18

Vacuum Contactor | 15

Molded Case Circuit Breaker


Optimum design provides easy-to-use customer installation, while offering versatility
and high performance to match today's demand for a reliable and cost-effective product,
which is easy to maintain.
Qualified Standard & Approval
Standard
IEC 60947-2
NEMA AB-1
KS C8321

Approval
ISO

18001, 14001, 9001


..
(Community European / TUV Rheinland)
TSE
GOST-R
CCC
KR, LR, ABS, BV, NK, GL
CE

HiBS 103

Category

E-Type

Type

Number of Breaking Current (kA)


poles (P) AC 220 AC 415 AC 600

2, 3, 4

10

2.5

HiBL 50NT

3, 4

125

85

35

2, 3, 4

10

2.5

HiBL 100NT

3, 4

125

85

35

HiBE 100

2, 3, 4

25

10

HiBL 225NT

3, 4

125

85

35

HiBE 225

2, 3, 4

35

18

7.5

HiBL 400

2, 3, 4

125

100

30

HiBE 250J

2, 3, 4

35

18

7.5

HiBL 600

2, 3, 4

125

100

35

HiBE 400

2, 3, 4

35

30

18

HiBL 800

2, 3, 4

125

100

35

HiBE 600

2, 3, 4

50

45

22

HiBL 50NE

3, 4

125

85

35

HiBE 800

2, 3, 4

50

45

25

HiBL 100NE

3, 4

125

85

35

HiBS 30

2, 3

10

2.5

HiBL 225NE

3, 4

125

85

35

HiBS 50

2, 3, 4

25

10

HiBL 400NE

3, 4

125

85

35

HiBS 60

2, 3, 4

25

10

HiBL 600NE

3, 4

125

85

42

HiBS 100

2, 3, 4

50

25

10

HiBL 800NE

3, 4

125

85

42

HiBS 100J

2, 3, 4

50

25

10

HiBL 1000NE

3, 4

150

130

65

2, 3, 4

50

25

10

HiBL 1200NE

3, 4

150

130

65

L-Type

2, 3, 4

50

25

10

HiBX 50NT

3, 4

150

130

65

HiBS 400

2, 3, 4

50

42

22

HiBX 100NT

3, 4

150

130

65

HiBS 600

2, 3, 4

100

65

25

HiBX 225NT

3, 4

150

130

65

HiBS 800

2, 3, 4

100

65

25

HiBX 400NE

3, 4

150

130

65

HiBS 400NE

3, 4

85

50

30

HiBX 600NE

3, 4

150

130

65

HiBS 600NE

3, 4

100

65

35

HiBX 800NE

3, 4

150

130

65

HiBS 800NE

3, 4

100

65

35

HiBC 32

1.5

HiBS 1000NE

3, 4

100

100

50

HiBC 32h

2.5

HiBS 1200NE

3, 4

100

100

50

HBD 50

1, 2, 3

2.5

HiBH 30

2, 3

25

10

HBD 50h

1, 2, 3

10

HiBH 50

2, 3, 4

50

25

10

HBD 52D

1, 2

HiBH 100

2, 3, 4

65

35

18

HiBD 63

1, 2, 3

6 (230 / 400 V)

HiBH 100J

2, 3, 4

65

35

18

HiBD 100

1, 2, 3

10 (230 / 400 V)

2, 3, 4

65

35

18

2, 3, 4

65

35

18

HiBH 400

2, 3, 4

85

65

25

HiBH 600

2, 3, 4

100

85

35

HiBH 800

2, 3, 4

100

85

35

HiBH 225
HiBH 250J

04

Type

HiBE 60

HiBS 250J

H-Type

Category

HiBS 803NE

HiBE 50

HiBS 225
S-Type

Number of Breaking Current (kA)


poles (P) AC 220 AC 415 AC 600

HiBL 203NE

X-Type

Distribution
and Lighting
Protection
Type
Miniature
Circuit
Breaker

2 poles are the same as 3 poles except that the conducts of


middle pole are removed.

MV & LV Circuit Breaker, Contactor & Overload Relay

Accessories

Inter Pole Barrier [ TQQ ]

Terminal Cover [ TCF ]


Auxiliary Switch [ AUX ]
Electrically indicates breaker
status ON or OFF.

Plug-in Mounting Base [ TDM ]


Allows the MCCB to be replaced
without disconnecting the power.

Alarm Trip Switch [ ALT ]


Electrically indicates the
tripped state of breaker.

Shunt Trip [ SHT ]


Carries out the electrical
remote trip of the breaker.

Under Voltage Trip [ UVT ]

Terminal Cover [ TCF ]


External Operating Handle [ TFG ]
Surface attached type (Panel mounted type)
The MCCB can be installed near the panel door.
The operating mechanism is attached on the
MCCB, and the external operating handle is
mounted on the panel door.

External Operating Handle [ TFH ]


Extended type (Panel mounted type)
The MCCB can be installed inside the panel.
The operating mechanism is attached on the MCCB,
and the external operating handle is mounted on the
panel door; where the handle and the mechanism
are mechanically connected by a shaft.

Automatically trips the breaker


when control voltage drops
below predetermined value.

Prevents direct contact on


the terminals for protection.

Inter Pole Barrier [ TQQ ]


Enhances the insulation between poles of
the MCCB in the line side and load side.
Can be attached easily onto the MCCB.

05

Contactor & Overload Relay


Magnetic Contactor
HYUNDAI Magnetic Contactor employs a modular design, which allows quick and simple
mounting of auxiliary contact blocks, timers, mechanical latching blocks, etc.
HiMC Contactor provides convenience, economic benefit and high reliability.
With highly advanced design for industrial applications such as motor control centers, the
HiMC contactor is appropriate for various control systems. It is also favored by shipyards
and power plants whose criteria includes high reliability and performance.
Qualified Standard & Approval
Standard
IEC 60947
EN 60947
UL 508
BS 47794, BS 5424, BS 4941
VDE 0660
Det Norske Veritas
KS C4504
JISC 8328, JEM 1038

Approval
ISO

18001, 14001, 9001


/ C-UL
..
CE (Community European / TUV Rheinland)
UL

TSE
GOST-R
CCC
KR,

LR, ABS, BV, NK

HiMC 22 + HiTH 22

Operational Voltage
Type

Capacity (AC 3, kW / A)
Auxiliary Contact

AC

DC

HiMC 9

2.2 / 10

4/9

4/7

5.5 / 7

1a1b

HiMC 12

3.7 / 13

5.5 / 12

7.5 / 12

7.5 / 9

1a1b

HiMC 18

4.5 / 18

7.5 / 18

8.5 / 15

7.5 / 9

1a1b

HiMC 22

5.5 / 22

11 / 22

15 / 22

15 / 18

1a1b

HiMC 32

7.5 / 32

15 / 32

18.5 / 28

18.5 / 22

2a2b

HiMC 40

11 / 40

18.5 / 40

22 / 32

22 / 26

2a2b

HiMC 50

15 / 50

22 / 50

30 / 45

25 / 31

2a2b1)

HiMC 65

18.5 / 70

30 / 65

37 / 60

37 / 44

2a2b1)

HiMC 80

22 / 80

37 / 80

45 / 64

45 / 52

2a2b1)

HiMC 90

25 / 90

45 / 90

50 / 80

50 / 60

2a2b1)

HiMC 110, HiMC 110B2)

30 / 110

55 / 110

60 / 110

55 / 65

65 / 50

2a2b1)

HiMC 130

37 / 130

65 / 130

70 / 120

60 / 70

75 / 54

2a2b1)

HiMC 150, HiMC 150B2)

45 / 150

75 / 150

90 / 140

90 / 100

90 / 66

2a2b1)

HiMC 180

55 / 180

90 / 180

110 / 180

110 / 120

110 / 78

2a2b1)

HiMC 220

63 / 220

110 / 220

132 / 200

132 / 150

132 / 96

2a2b1)

HiMC 260

75 / 260

132 / 260

150 / 220

160 / 173

160 / 113

2a2b1)

HiMC 300

90 / 300

160 / 300

160 / 273

200 / 220

200 / 141

2a2b1)

HiMC 400

125 / 400

220 / 400

220 / 350

250 / 300

250 / 178

2a2b1)

HiMC 500

140 / 500

250 / 500

300 / 426

335 / 360

275 / 192

2a2b1)

HiMC 630

190 / 630

330 / 630

330 / 500

400 / 412

300 / 213

2a2b1)

HiMC 800

220 / 800

440 / 800

500 / 720

500 / 630

400 / 284

2a2b1)

1) The auxiliary contact for DC is 2a1b


2) Compact type contactor

06

HiMC 130F22

AC / DC 220~240 V 380~440 V 500~550 V 660~690 V

1000 V

MV & LV Circuit Breaker, Contactor & Overload Relay

HiMC 9 ~ HiMC 50

[ Small Frame Size Contactor ]

2
1

5
1

8
2

HiMC 65 ~ HiMC 800

[ Large Frame Size Contactor ]

5
1
2

7
7
8

1. Contactor : HiMC 9~800


2. Auxiliary Contact Block
3. Mechanical Latching Block
4. Electronic Timer Block
5. Mechanical Interlock Unit
6. Surge Absorber
7. Insulation Barrier Unit
8. Thermal Overload Relay
9. Digital Motor Protection Relay

07

Contactor & Overload Relay


Thermal Overload Relay

HiTH 40K(H)

HiTH 50K(H)

HiTH 90K(H)

HiTH 130K80

Category

HiTH 22K(H)

HiTH 40K(H)

HiTH 50K(H)

HiTH 90K(H)

Applied Contactor

HiMC 9 ~ 22

HiMC 32 ~ 40

HiMC 50

HiMC 65 ~ 90

Rated Current

0.18 ~ 22

10 ~ 40

26 ~ 50

40 ~ 90

K-Type

3 Element

3 Element

3 Element

3 Element

H-Type

2 Element

2 Element

2 Element

2 Element

Number of Element
Auxiliary Contact

1a1b

1a1b

1a1b

1a1b

Reset Type

Manual / Auto Unit

Manual / Auto Unit

Manual / Auto Unit

Manual / Auto Unit

Phase Fault Protection

K-Type Only

K-Type Only

K-Type Only

K-Type Only

Main Circuit

1~6

2 ~ 14

2 ~ 22

2 ~ 35

Control Circuit

2 0.75 ~ 2.5

2 0.75 ~ 2.5

2 0.75 ~ 2.5

2 0.75 ~ 2.5

0.17(0.16)

0.23(0.22)

0.28(0.27)

0.53(0.51)

Suitable Wire ()

Net Weight (kg)


K-Type (H-Type)

CT Assembly
Category

HiTH 130K(H)

HiTH 220K(H)

HiTH 300K(H)

HiTH 500K(H)

HiTH 800K(H)

Applied Contactor

HiMC 110 ~ 130

HiMC 150 ~ 220

HiMC 260 ~ 300

HiMC 400 ~ 500

HiMC 630 ~ 800

Rated Current

80 ~ 130

130 ~ 220

220 ~ 300

300 ~ 500

630 ~ 800

Feature

CT Assembly

CT Assembly

CT Assembly

CT Assembly

CT Assembly

K-Type

3 Element

3 Element

3 Element

3 Element

3 Element

H-Type

2 Element

2 Element

2 Element

2 Element

2 Element

1a1b

1a1b

1a1b

1a1b

1a1b

Number of Element
Auxiliary Contact
Reset Type
Phase Fault Protection
Suitable Wire ()

K-Type Only

K-Type Only

K-Type Only

K-Type Only

K-Type Only

Main Circuit

Control Circuit

2 0.75 ~ 2.5

2 0.75 ~ 2.5

2 0.75 ~ 2.5

2 0.75 ~ 2.5

2 0.75 ~ 2.5

1.65(1.3)

1.85(1.49)

1.94(1.59)

2.25(1.88)

5.7(4.62)

Net Weight (kg)

08

Manual / Auto Unit Manual / Auto Unit Manual / Auto Unit Manual / Auto Unit Manual / Auto Unit

MV & LV Circuit Breaker, Contactor & Overload Relay

Saparate Mounting Unit (HiTHMB)

Separate Mounting Unit


Type

For use with


Overload Relay Type

HiTHMB 22

HiTH 22

HiTHMB 40

HiTH 40

HiTHMB 50

HiTH 50

HiTHMB 90

HiTH 90

Mounting

DIN Rail Screw

Ratings Overview
Setting Range

Relay Types (Standard Type)


HiTH 22K

HiTH 40K

HiTH 50K

HiTH 90K

HiTH 130K

HiTH 220K

HiTH 300K

HiTH 500K

HiTH 800K

0.12~0.18 A
0.18~0.26 A
0.25~0.35 A

CT Operated Type

0.34~0.5 A
0.5~0.7 A
0.6~0.9 A
0.8~1.2 A
1.1~1.6 A
1.5~2.1 A
2~3 A
2.8~4.2 A
3~5 A
4~6 A
5.6~8 A
7~10 A
9~13 A
12~18 A
16~22 A
18~26 A
24~32 A
28~40 A
36~50 A
45~65 A
60~80 A
70~90 A
48~80 A
78~130 A
108~180 A
132~220 A
180~300 A
240~400 A
300~500 A
378~630 A
480~800 A

09

Contactor & Overload Relay


Accessory
Control Relay
Category

AC

DC

Type

Auxiliary Contact

Additional Contact

HMX 22

2a2b

4a, 3a1b, 2a2b, 1a3b, 4b

HMX 31

3a1b

4a, 3a1b, 2a2b, 1a3b, 4b

HMX 40

4a

4a, 3a1b, 2a2b, 1a3b, 4b

HMT 22

2a2b

4a, 3a1b, 2a2b, 1a3b, 4b

HMT 31

3a1b

4a, 3a1b, 2a2b, 1a3b, 4b

HMT 40

4a

4a, 3a1b, 2a2b, 1a3b, 4b

HMT & HMX

Electronic Timer Block


Type

Control Voltage

Delay Time

HOKZE 1

AC / DC 90~240 V

0.15~220 sec

HOKZE 2

AC / DC 24~60 V

0.15~220 sec
Electronic Timer Block

Mechanical Latching Block


Type

Control Voltage

HLB 2

AC 24, 48, 110, 220, 440 V / DC 24, 48, 110, 220 V

Mechanical Interlock Unit

Mechanical Latching Block

Type

Contactors

HiTL 40

HiMC 9 ~ 40

HiTL 50

HiMC 50

HiTL 130

HiMC 65 ~ 130, 150B

HiTL 220

HiMC 150 ~ 220

HiTL 300

HiMC 260 ~ 300

HiTL 800

HiMC 400 ~ 800

Surge Absorber
Type
HRC 40 / 48

28 ~ 48 V

HRC 40 / 220

110 ~ 220 V

HRC 40 / 380

240 ~ 380 V

HRC 90 / 48

28 ~ 48 V

HRC 90 / 220

110 ~ 220 V

HRC 90 / 380

240 ~ 380 V

HRC 300 / 48

28 ~ 48 V

HRC 300 / 220

110 ~ 220 V

HRC 300 / 380

240 ~ 380 V

HOKYZX 38

10

Voltage

DC

Application
HMX
HiMC 9W ~ 40W

Surge Absorber

HiMC 50W
HiMC 65W ~ 90W, 110B

HiMC 110W ~ 300W


HMT, HiMC 9G ~ 50G

Diagram

MV & LV Circuit Breaker, Contactor & Overload Relay

HiAC 22

HiAC 20

HiAL 11

HiAL 5S

HiAR 6S

HiMK

Auxiliary Contact Block


Type

Consist

Mounting

HiAB 22

2NO + 2NC

Top Side

Application

HiAB 13

1NO + 3NC

Top Side

HiAB 31

3NO + 1NC

Top Side

HiAB 04

0NO + 4NC

Top Side

HiAB 40

4NO + 0NC

Top Side

HiAB 11

1NO + 1NC

Top Side

HiAB 02

0NO + 2NC

Top Side

HiAB 20

2NO + 0NC

Top Side

HiAL 111)

1NO + 1NC

Left Hand Side

HiAC 22

2NO + 2NC

Top Side

HiAC 13

1NO + 3NC

Top Side

HiAC 31

3NO + 1NC

Top Side

HiAC 40

4NO + 0NC

Top Side

HiAC 11

1NO + 1NC

Top Side

HiAC 02

0NO + 2NC

Top Side

HiAC 20

2NO + 0NC

Top Side

HiAL 5S

1NO + 1NC

Left Hand Side

HiAR 6S

1NO + 1NC

Right Hand Side

HiAL 7S

1NO + 1NC

Left Hand Side

HiAR 8S

1NO + 1NC

Right Hand Side

HiMC 9 ~ 50

HiMC 9 ~ 22

HMX
HMT

HiMC 65 ~ 130, 150B


HiMC 150 ~ 800

1) The side mounting auxiliary contact block shall not be used with the top mounting aux. contact block at the same time.

Capacitor Switching Contactor


Rating of 3-phase Capacitor 50~60 Hz
(at ambient temperature 55 )
Type
(AC Operation)

Composed Devices

AC-6b
Max. Power
200 V 230 V
240 V
kVAR kVAR

Contactor
AC Operational

400 V
415 V
kVAR

440 V
kVAR

500 V
550 V
kVAR

9.7

9.7

14

6.7

6.7

12.5

12.5

18

8.5

8.5

16.7

16.7

24

14

HiMC 9W

18

HiMC 12W

24

HiMC 18W

HiMK 22W 21
HiMK 22W 12

10

10

18

18

26

26

HiMC 22W

14

16

27.5

30

34

45

HiMC 32W

HiMK 32W 32
HiMK 32W 23
HiMK 40W 32
HiMK 40W 23

20

20

30

33.3

48

48

HiMC 40W

HiMK 50W 32
HiMK 50W 23

21

24

40

45

50

Auxiliary
NO
NC
(53-54) (51-52)

65

External Size
WxHxD

mm
HiAD 1A 22

HiMK 18W 21
HiMK 18W 12

Type

kVAR

HiMK 12W 21
HiMK 12W 12

Capacitor Switching Unit

690 V

HiMK 9W 21
HiMK 9W 12

Dimension

HiMC 50W

HiAD 1B 22

HiAD 1A 22

HiAD 1B 22

HiAD 1A 22

HiAD 1B 22

HiAD 1A 22

HiAD 1B 22

HiAD 1A 50

HiAD 1B 50

HiAD 1A 50

HiAD 1B 50

HiAD 1A 50

HiAD 1B 50

44 x 166 x 123

63 x 166 x 123

70 x 178 x 136

11

Contactor & Overload Relay


Digital Motor Protection Relay
High Reliability
HiMP series provides superior reliability by the Micro
Controller Unit (MCU)

Electron Wave and Noise Tolerance


Completed to EMS test.
Secured from the magnetic field as using troidal CT.

Applicable to the Inverter Control Circuit


HiMP series have high performance under the harmonic
noise, so they can be used for the inverter control circuit
under 20~200 Hz range.

Various Wiring Methods


Pin type : Directly mountable to HiMC series contactors
Screw type : Connectable to other devices with screws and cables
Tunnel type : Cables go through 12 mm cable holes

Ratings Overview
Characteristic
Curve

Type

Definite
HiMP 22
Inverse
Definite
Inverse

HiMP 40

Definite

HiMP 50

Inverse
Definite / Inverse

HiMP-D

Current Range

Relay Selection
Ecomomic Type

0.3~3.0 A
0.6~6.0 A
2.2~22 A
0.3~1.5 A
1.0~5.0 A
4.4~22 A
4.0~40 A
8.0~40 A
5.0~50 A
6.0~50 A
10~50 A
0.5~6.0 A
5.0~60 A

Standard Type

Deluxe Type

Economic Type
Type
(Basic)

Number of
CTs

HiMP 22
Pin Type

HiMP 40
Screw Type

HiMP 50
Tunnel Type

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Characteristic
Current Range
Curve

Auxiliary
Contact 1)
1SPDT

0.6~6.0 A
2SPST
Definite
1SPDT
2.2~22 A
2SPST

1SPDT
Definite

4.0~40 A
2SPST

1SPDT
Definite

6.0~50 A
2SPST

1) 2SPST becomes 1a1b when control power is on. 1SPDT becomes 1c when control power is on.

12

Connection
Type

Ordering Type

Pin
Screw
Tunnel
Pin
Screw
Tunnel
Pin
Screw
Tunnel
Pin
Screw
Tunnel
Pin
Screw
Tunnel
Pin
Screw
Tunnel
Pin
Screw
Tunnel
Pin
Screw
Tunnel

HiMP 22H-PE-06
HiMP 22H-SE-06
HiMP 22H-TE-06
HiMP 22H-PS-06
HiMP 22H-SS-06
HiMP 22H-TS-06
HiMP 22H-PE-22
HiMP 22H-SE-22
HiMP 22H-TE-22
HiMP 22H-PS-22
HiMP 22H-SS-22
HiMP 22H-TS-22
HiMP 40H-PE-40
HiMP 40H-SE-40
HiMP 40H-TE-40
HiMP 40H-PS-40
HiMP 40H-SS-40
HiMP 40H-TS-40
HiMP 50H-PE-50
HiMP 50H-SE-50
HiMP 50H-TE-50
HiMP 50H-PS-50
HiMP 50H-SS-50
HiMP 50H-TS-50

MV & LV Circuit Breaker, Contactor & Overload Relay

Standard Type
Type
(Basic)

Number of
CTs 1)

Pin Type

HiMP 22

Screw Type

Tunnel Type

HiMP 40

HiMP 50

2
2
2
2
2
2
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
3
3
3
3
3
3
3
3
3
2
2
2
2
3
2
3
2
3
3
3
3
2
2
2
2
3
2
3
2
3
3
3
3

Characteristic
Current Range
Curve

Auxiliary
Contact 2)

0.3~3.0 A

2SPST

2.2~22 A

2SPST

Definite

Connection
Type
Pin
Screw
Tunnel
Pin
Screw
Tunnel
Pin

0.3~1.5 A

2SPST

Screw
Tunnel
Pin

Inverse

1.0~5.0 A

2SPST

Screw
Tunnel
Pin

4.4~22 A

2SPST

Screw
Tunnel

Inverse
(with Reverse
Protection)

Definite

0.3~1.5 A

2SPST

1.0~5.0 A

2SPST

4.4~22 A

2SPST

4.0~40 A

2SPST

Pin
Screw
Tunnel
Pin
Screw
Tunnel
Pin
Screw
Tunnel
Pin
Screw
Tunnel
Pin

Inverse

8.0~40 A

2SPST

Screw
Tunnel

Inverse
(with Reverse
Protection)

8.0~40 A

2SPST

Definite

5.0~50 A

2SPST

Pin
Screw
Tunnel
Pin
Screw
Tunnel
Pin

Inverse

10~50 A

2SPST

Screw
Tunnel

Inverse
(with Reverse
Protection)

10~50 A

2SPST

Pin
Screw
Tunnel

Ordering Type
HiMP 22H-PD-03
HiMP 22H-SD-03
HiMP 22H-TD-03
HiMP 22H-PD-22
HiMP 22H-SD-22
HiMP 22H-TD-22
HiMP 22H-PI-01
HiMP 22K-PI-01
HiMP 22H-SI-01
HiMP 22K-SI-01
HiMP 22H-TI-01
HiMP 22K-TI-01
HiMP 22H-PI-05
HiMP 22K-PI-05
HiMP 22H-SI-05
HiMP 22K-SI-05
HiMP 22H-TI-05
HiMP 22K-TI-05
HiMP 22H-PI-22
HiMP 22K-PI-22
HiMP 22H-SI-22
HiMP 22K-SI-22
HiMP 22H-TI-22
HiMP 22K-TI-22
HiMP 22K-PN-01
HiMP 22K-SN-01
HiMP 22K-TN-01
HiMP 22K-PN-05
HiMP 22K-SN-05
HiMP 22K-TN-05
HiMP 22K-PN-22
HiMP 22K-SN-22
HiMP 22K-TN-22
HiMP 40H-PD-40
HiMP 40H-SD-40
HiMP 40H-TD-40
HiMP 40H-PI-40
HiMP 40K-PI-40
HiMP 40H-SI-40
HiMP 40K-SI-40
HiMP 40H-TI-40
HiMP 40K-TI-40
HiMP 40K-PN-40
HiMP 40K-SN-40
HiMP 40K-TN-40
HiMP 50H-PD-50
HiMP 50H-SD-50
HiMP 50H-TD-50
HiMP 50H-PI-50
HiMP 50K-PI-50
HiMP 50H-SI-50
HiMP 50K-SI-50
HiMP 50H-TI-50
HiMP 50K-TI-50
HiMP 50K-PN-50
HiMP 50K-SN-50
HiMP 50K-TN-50

1) For 2CT type, just R and T phase protection is applicable.


2) 2SPST becomes 1a1b when control power is on.

13

Contactor & Overload Relay


Digital Motor Protection Relay
Deluxe Type
Basic Type

Protection

Over-current

Connection Type

Current Range Ordering Type


0.5~6.0 A

HiMP-D06S

5.0~60 A

HiMP-D60S

0.5~6.0 A

HiMP-D06T

5.0~60 A

HiMP-D60T

0.5~6.0 A

HiMP-D06SI

5.0~60 A

HiMP-D60SI

0.5~6.0 A

HiMP-D06TI

5.0~60 A

HiMP-D60TI

0.5~6.0 A

HiMP-D06SZ

5.0~60 A

HiMP-D60SZ

0.5~6.0 A

HiMP-D06TZ

5.0~60 A

HiMP-D60TZ

Screw

Under-current
Phase Failure
Phase Unbalance
Restriction

Screw Unit

Screw Extension

Tunnel

Over-current
Under-current
Phase Unbalance
Short Circuit

Tunnel Unit

Tunnel Extension

Phase Unbalance
Leakage Current

Display Bracket

Screw

Phase Failure
Restriction

Connecting Cable

Tunnel

Over-current
Under-current

When extension type


is selected connecting
cable and display
braket should be
ordered separately

Screw

Phase Failure
Restriction

Remarks

Tunnel

High-trust Realization
The micro controller unit of HiMP series provides superior
reliability.
Real time processing and high precision.
Various Protective Features
Basic functions
Over-current / Under-current
Stall / Lock
Phase Loss / Phase unbalance / Reverse phase
Optional functions
Earth leakage current
Short circuit current

Preliminary Alert Function


HiMP series can prevent the sudden over-current trip
through the preliminary alert function.
HiMP series can be inspected easily due to displaying load
ratio by bar-graph during operation.

Digital Ampere Meter Function


HiMP series are able to check the three phase ampere
without additional ampere meter.
Display the Cause of Fault
Easy maintenance and repair

Operating Time Function


Accumulated motor operation time can be displayed.
Certain operating time can be set to alert, so oil exchange
point can be checked conveniently.

14

Selectable Inverse and Definite Curve


Applicable to the Inverter Control Circuit

MV & LV Circuit Breaker, Contactor & Overload Relay

Vacuum Contactor
HYUNDAI HCA series high voltage vacuum contactors are designed and manufactured
for frequent switchings, especially taking into account of safety and quality assurance.
They are suitable for switching and controlling 3 phase motors with a squirrel cage
and slipring rotor, high voltage load and resistance furnace, and a capacitor and
transformer which is of the dried or moulded type.
Qualified Standard & Approval
Standard
IEC 60470
NEMA ICS3

Approval
ISO

18001, 14001, 9001


ABS, BV, NK, KR

LRS,

General Characteristics
HCA Type
Ordering Informations

HCA
Digit
Digit
Digit 1
Digit 2
Digit 3

Digit 4

Digit 5

Digit 6

Description
Rated voltage
Rated current
Energizing type

Frame structure

Operating voltage

Cradle

Digit 7

Fuse

8
Specification

Accessories

Code

3.3 kV

6.6 kV

200 A

400 A

Continuously energized

Latched

Fixed type without fuse holder

Fixed type with single fuse holder

Fixed type with double fuse holder

Draw-out type without fuse holder

Draw-out with single fuse holder

Draw-out type with double fuse holder

DC 110 V

DC 220 V

AC 110 V

AC 220 V

DC 125 V

AC 120 V

E : No shutter

F : Insulation shutter

M : Metal shutter, bushing

T : Metal shutter, bushing with earthing switch

Fixed type

O
- 1)

Fuse rating
CTD

Digit 8

12

AC 110 V

AC 220 V

Electrical interlock

Fuse melting detector

M
P

Position switch
3.3 kV / 200 VA

4.16 kV / 200 VA

Potential

6.6 kV / 200 VA

transformer

3.3 kV / 200 VA

4.16 kV / 200 VA

6.6 kV / 200 VA

Digit 12

1set

2set
1) Fuse list is available upon request.

15

Air Circuit Breaker


Designed for industrial and marine application, HYUNDAI ACB is built with innovated
structure, increased protection, and reliable performance.
Qualified Standard & Approval
Standard
IEC 60947-2
EN 60947-2
AS 3972-2
NEMA PUB NO. SG3
ANSI C37.13
GOST-R 50030.2-99 9
GOST-R 50030.1-2000

Approval
ISO

18001, 14001, 9001


..
(Community European / TUV Rheinland)
GOST-R
CCC
KR, GL, LR, ABS, BV, NK
CE

Rated Breaking
Rated Making
Number
Rated
Charging
Capacity (kA)
Capacity (kA)
of Poles Insulation
Mechanism
(P)
Voltage (V) (500V, With Inst.) (500V, With Inst.)

Type

Rated Current
(A)

HiAN06

630

70

154

HiAN08

800

70

154

HiAN10

1000

70

154

HiAN12

1250

70

154

HiAN16

1600

70

154

HiAN20

2000

70

154

HiAN25

2500

85

187

HiAN32

3200

85

187

HiAN40

4000

100

220

HiAN50

5000

120

286

HiAN63

6300

120

286

HiAS06

630

50

110

HiAS08

800

50

110

HiAS10

1000

50

110

HiAS12

1250

50

110

HiAS16

1600

50

110

HiAS20

2000

65

143

HiAS25

2500

65

143

HiAS32

3200

65

143

HAT06

630

50

105

HAT08

800

65

143

HAT10

1000

65

143

HAT12

1250

65

143

HAT16

1600

65

143

HAT20

2000

65

143

HAT25

2500

65

143

HAT32

3200

85

187

HAT40

4000

85

187

HAT50

5000

100

220

HAS06

630

50

105

HAS08

800

65

143

HAS10

1000

65

143

HAS12

1250

65

143

HAS16

1600

65

143

HAS20

2000

65

143

HAS25

2500

65

143

HAS32

3200

85

187

3, 4

3, 4

2, 3, 4

2, 3, 4

AC1000

AC1000

AC1000

AC1000

HiAN Type

HiAS Type

Manual
and
Motor
Charging

All HYUNDAIs ACB has the function of N phase close before R, S & T and N phase open after R, S & T in accordance with IEC 60947-2.

16

HAT Type

HAS Type

MV & LV Circuit Breaker, Contactor & Overload Relay

APR (ACB Protection Relay) Characteristics for HiAN Type


Application

General Feeder

Generator

Type

Protective Function

APR-1L-AL

AL

AS

AI

Indicating Function
IU

APR-1L-AS

AL

AS

AI

AP

MCR

NP

APR-1L-AM

AL

AS

AI

AP

MCR

NP

APR-1L-GL

AL

AS

AI

APR-1L-GS

AL

AS

AI

AP

AG

MCR

NP

APR-1L-GM

AL

AS

AI

AP

AG

MCR

NP

MCR

NP

APR-2L-GS

AL

AS

AI

AP

AG

AL

AS

AI

AP

AG

LED
LED

IU

AG

APR-1D-GM

CP / I
IUt

CP / I
IUt

LED
LED

CP / I

LED

CP / I

LED

IU

APR-1S-AL

AL

AS

AI

APR-1S-AS

AL

AS

AI

AP

MCR

CP / I

LED

APR-2S-AS

AL

AS

AI

AP

MCR

CP / I

LED

OCR (Over Current Relay) Characteristics for HAT Type


Application

Type

Protective Function

AOR-1L-AL

AL

AS

AI

AOR-1L-AS

AL

AS

AI

AOR-1L-GL

AL

AS

AI

Indicating Function
IU
MCR

AP

AOR-1L-GS

AL

AS

AI

AP

AOR-1L-AM

AL

AS

AI

AP

AOR-1L-GM

AL

AS

AI

AP

AG

AOR-1L-GM
(Digital Display Type)

AL

AS

AI

AP

AG

AOR-1S-AL

AL

AS

AI

AOR-1S-AS

AL

AS

AI

AG

General Feeder

Generator

Protective Function
AL

Adjustable Long Time Delay Trip

AS

Adjustable Short Time Delay Trip

AI

Adjustable Instantaneous Trip

AP

Adjustable Pre-trip Alarm

AG

Adjustable Ground Fault Trip

MCR

Making Current Release Function

NP

Neutral Phase Protection Function

CP / I
IU

AG
MCR

CP / I

MCR

IU

CP / I

MCR

IU

CP / I

IU

CP / I

IU
AP

MCR

CP / I

Indicating Function
IU

IUt

CP / I

LED

Integrated Indicating Operation LED & Contact


1a contact makes the signal during 40 ms when a
protective function operates.
Insulation level from earth is 1500 V.
Integrated Indicating Operation LED & Contact
2a contacts make the signal until the RESET button
is pushed when protective function operates.
Insulation level from earth is 1500 V.
Individual Indicationg Operation Contact 2a contacts
make the signal until the RESET button is pushed
which protective function operates.
Insulation level from earth is 1500 V.
Individual Indicating Operation LED.
Each LED indicates until the RESET button is
pushed which protective function operates.

17

Vacuum Circuit Breaker


HYUNDAI VCB garners superior reputation with its extended life expectancy, easy
maintenance, and excellent performance for industrial facilities, power plants,
and marine vessels.
Qualified Standard & Approval
Standard
IEC 62271-100, 60056
ESB 150
ANSI C37
KSC 4611

Approval
ISO
KR,

18001, 14001, 9001


GL

HVF Type

HVG Type

IEC 62271-100
Type

Rated
Voltage
(kV)
4.76

7.2

Withstand
Rated
Applied
Voltage (kV)
Power-frequency Breaking Standard
Current(kA)
/ Impulse

19 / 60

20 / 60

12

28 / 75

15

36 / 95

HVF Type

17.5

24 / 25.8
36

HVG Type

7.2

Type number in the square


3000 / 3150A
400A

18

38 / 95

50 / 125
70 / 170

20 / 60

Rated Current (A)


Type
400

630

1250

2000

3150

50

ANSI

25

IEC

HVF114

31.5

IEC

HVF115

40

IEC

HVF116

25

IEC

HVF214

31.5

IEC

HVF215

40

IEC

HVF216

HVF137

40

ANSI

HVF336

25

IEC

HVF314

31.5

IEC

HVF315

40

IEC

HVF316

12.5

IEC

HVF611

25

IEC

HVF614

25

IEC

HVF714

IEC

HVG109

12.5

IEC

HVG101

20

IEC

HVG113

25

IEC

HVG114

shall be listed as shown in the line for the rated current :

2500

600 / 630A

1200 / 1250A

2000A

2500A

MV & LV Circuit Breaker, Contactor & Overload Relay

HVF Type

HAF Type

IEC 60056
Type

Rated
Voltage
(kV)

7.2

12

Withstand
Rated
Applied
Voltage (kV)
Power-frequency Breaking Standard
Current(kA)
/ Impulse

20 / 60

28 / 75

HVF Type

24

50 / 125

38

80 / 150

4.76

19 / 60

7.2

12

20 / 60

28 / 75

HAF Type
(3AF Type)

15

36 / 95

24
50 / 125
(25.8)

HVG Type

7.2

20 / 60

630

1250

2000

25

IEC

HVF104

31.5

IEC

HVF105

40

IEC

HVF106

25

IEC

HVF204

400

2500

3150

31.5

IEC

HVF205

40

IEC

HVF206

50

IEC

HVF207

12.5

IEC

HVF601

25

IEC

HVF604

31.5

IEC

HVF605

40

IEC

HVF606

31.5

ANSI

HVF705

40

ANSI

HVF706

50

ANSI

HAF107

-3

HAF104

-4

25

IEC

31.5

IEC

HAF105

-4

40

IEC / ESB

HAF116

-3

50

IEC

HAF117

-3

25

IEC

HAF154

-4

31.5

IEC

HAF175

-4

40

IEC

HAF176

-3

50

IEC

HAF177

-3

25

IEC

HAF234

-4

31.5

IEC

HAF235

-4

40

IEC / ANSI

HAF236

-3

12.5

IEC

HAF611

-4

16

IEC

HAF612

-4

20

IEC

HAF613

-4

-4

25

IEC / ESB

HAF614

20

IEC

HVG103

HVG104

25
Type number in the square
3000 / 3150A
400A

Rated Current (A)


Type

IEC

shall be listed as shown in the line for the rated current :

600 / 630A

1200 / 1250A

2000A

2500A

19

HHIS-WC-LE-A39-05, 2007.3 Designed by Design Korea

www.hyundai-elec.com

Head Office

1 Jeonha-dong, Dong-gu, Ulsan, Korea


Tel. 82-52-202-8101~8
Fax. 82-52-202-8100

Seoul
(Sales & Marketing)

140-2, Gye-dong, Jongno-gu, Seoul, Korea


Tel. 82-2-746-7510, 7589
Fax. 82-2-746-7648

Orlando

3452 Lake Lynda Drive, Suite 170, Orlando, Florida 32817, U.S.A.
Tel. 1-407-249-7350
Fax.1-407-275-4940

London

2nd Floor, The Triangle, 5-17 Hammersmith Grove London, W6 0LG, UK


Tel. 44-20-8741-0501
Fax. 44-20-8741-5620

Tokyo

8th Fl., Yurakucho Denki Bldg.1-7-1, Yuraku-cho, Chiyoda-gu, Tokyo 100-0006, Japan
Tel. 81-3-3212-2076, 3215-7159
Fax. 81-3-3211-2093

Cairo

Apartment No. 503, 5th Fl., Bldg. No. 7 Block 2, 9th Division, El-nasr Road, New Maadi, Cairo, Egypt
Tel. 20-2-520-0148~9
Fax. 20-2-754-7528

Sofia

1271, Sofia 41, Rojen Blvd. Bulgaria


Tel. 359-2-803-3200
Fax. 359-2-803-3203

Yangzhong

Lianzhong Avenue, Xinba Scientific and Technologic Zone, Yangzhong City, Jiangsu 212212, China
Tel. 86-511-842-0666, 0500
Fax. 86-511-842-0668, 0231
Recyled paper used for environmental protection.

Potrebbero piacerti anche