Sei sulla pagina 1di 3

DEVELOPED BY:

CONTACT:
DATE:

SCOPE OF WORK HERE

PROJECT:
PROJECT #:

Lighting System Data

Existing System

Quantity of Fixtures
Lighting System
Fixture Wattage Lamp, Module or Lamp/Ballast, Module/Driver Combination
Lamp/Module Life, Rated Hours
Per Lamp/Module Cost
Per Lamp/Module Re-lamping Cost
Occupancy Rate (Percentage of time off)
System Operating Data & Costs

Proposed System

0%

Average kWh Cost--->

Operating Hours per Year (Existing vs modified proposed with occupancy)


Total Wattage / Total System
Total Kilowatts / Total System
Total Kilowatt Hours / Total System
Annual Energy Costs
Annual Lamp/Module Maintenance Costs (Based on Life Cycle in Years)
Annual Operating Costs

$0.00
0
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

0
0
0
$0
#VALUE!
#VALUE!

Project Implementation Costs

Fixture Sell Price


Fixture Installation Sell Price
Recycling & Disposal Sell Price
Total Project Sell Price (Invoice Amount to Customer)
Rebate (Custom - based on kWh saved 0.00
kWh Rebate Amount
Rebate (Prescriptive - per unit price)
0.00
Per Fixture Amount
Total Project Cost after Rebates
Project Payback Analysis

$0
$0
$0
$0
#VALUE!
$0.00
#VALUE!

Life Cycle Calculation Years--->

Annual Energy Savings from Project


Annual Maintenance Savings from Project
Simple Payback in Years
Return on Investment
Life Cycle Savings based on Calculation Years
Life Cycle CO2 Emissions Reduction based on Calculation Years*

0
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

$10.00
$9.00
$8.00
$7.00
$6.00
Annual Operating Costs

$5.00
$4.00
$3.00
$2.00
$1.00
$0.00
Existing System

Proposed System

Fulham ROI Calculator

The Fulham ROI Calculator in Sheet 1 of this Workbook is designed to provide basic LED savings calculations.
All the light yellow fields are unprotected cells intended for users to input data.
1 DEVELOPED BY, CONTACT, DATE, PROJECT, PROJECT #, and SCOPE OF WORK HERE are all for your reference
purposes to differentiate this worksheet from others. Leaving fields blank will not affect the analysis.
2 QUANTITY OF FIXTURES - Input the number of current fixtures in the left column. Typically, the right column will
be the same, unless fewer LED fixtures are anticipated to be needed in order to replace the existing systems.
Cell F11 should never exceed cell E11.
3 LIGHTING SYSTEM is a qualitative field for you to type the kind of system you currently have, e.g. "Metal Halide"
and the details of the LED system you are doing the analysis of in the right column.
4 FIXTURE WATTAGE - Here, you have a choice. You can use the lamp/modules' "stated wattages," for example, 400W MH and
250W LED, or you can use the "system wattages," if you know them. "System wattages" are always slightly
higher because it takes extra energy (some of which is lost to heat) to power lamps/modules of stated wattages. Typically,
LED is a more efficient system, meaning that a smaller percentage of energy is lost to heat than alternatives.
5 LAMP/MODULE LIFE/RATED HOURS is for inputting the life hours of lamps/modules of different types of systems. LED's rated
hours are 50,000, for instance, while most alternatives to LED are considerably lower.
6 PER LAMP/MODULE COST - This is literally the anticipated cost of each new lamp needed of each respective type.
7 PER LAMP/MODULE RE-LAMPING COST - Maintenance costs for replacing expired lamps/modules are considerable
and contribute heavily to the financial benefits of LED over other alternatives. Since LED lasts many
multiples of alternatives, this cost is cut down drastically.
8 OCCUPANCY RATE: If you anticipate taking advantage of LED's capabilities, such that you can
turn the modules off for a certain percentage of the day compared with how you are using your existing systems now,
please enter that incremental percentage of time off into this field on the right. Oftentimes, traditional alternatives
with very long re-strike are left on 24/7, but switching to LED technology means that modules can be turned off to save
energy and extend system life.
9 AVERAGE KWH COST is the cents you pay on average for energy based on actual cost per kWh plus tariffs,
demand charges, taxes and miscellaneous charges based on tier levels.
10 OPERATING HOURS PER YEAR- This is for your CURRENT operating hours with the existing system. Notice that the
hours for LED will be adjusted based on the OCCUPANCY RATE as per 8 above.
11 PROJECT IMPLEMENTATION COSTS - These three fields encapsulate the sell price of the fixture, fixture installation,
sell price and disposal of the prior fixture sell price. These must be end-user prices, rather than costs.
12 REBATES - Enter your custom rebate amount based on kWh saved, and enter incentive amounts per fixture replaced.
13 LIFE CYCLE CALCULATION IN YEARS - We typically enter 5 years into this calculation to match the duration of our
Limited Warranty.

DEVELOPED BY:
CONTACT:
DATE:

RETROFIT ALL FIXTURES WITH NEW LED LIGHTING

PROJECT:
PROJECT #:

Lighting System Data

3/28/2007
PARKING- LOT1
1234

Existing System

Proposed System

100
METAL HALIDE
460
20,000
$25
$75

100
LED
210
100,000
$125
$75
0%

Average kWh Cost--->

$0.14

4,380
46,000
46
201,480
$28,207
$913
$29,119.70

4,380
21,000
21
91,980
$12,877
$365
$13,242.20

Quantity of Fixtures
Lighting System
Fixture Wattage Lamp, Module or Lamp/Ballast, Module/Driver Combinat
Lamp/Module Life, Rated Hours
Per Lamp/Module Cost
Per Lamp/Module Re-lamping Cost
Occupancy Rate (Percentage of time off)
System Operating Data & Costs

ABC LIGHTING
M. ALEMAN

Operating Hours per Year (Existing vs modified proposed with occupancy)


Total Wattage / Total System
Total Kilowatts / Total System
Total Kilowatt Hours / Total System
Annual Energy Costs
Annual Lamp/Module Maintenance Costs (Based on Life Cycle in Years)
Annual Operating Costs
Project Implementation Costs

Fixture Sell Price


Fixture Installation Sell Price
Recycling & Disposal Sell Price
Total Project Sell Price (Invoice Amount to Customer)
Rebate (Custom - based on kWh saved 0.05 kWh Rebate Amount
Rebate (Prescriptive - per unit price) 100.00 Per Fixture Amount
Total Project Cost after Rebates
Project Payback Analysis

Life Cycle Calculation Years--->

Annual Energy Savings from Project


Annual Maintenance Savings from Project
Simple Payback in Years
Return on Investment
Life Cycle Savings based on Calculation Years
Life Cycle CO2 Emissions Reduction based on Calculation Years*

Annual Operating Costs

$30,000.00
$20,000.00
$10,000.00
$0.00
Existing System

Proposed System

ROI Calculator Example

$300
$75
$5
$38,000
$5,475
$10,000.00
$22,525.00
5
$15,330
$548
1.42
68.06%
$79,388
285.52 tons