It is the most important test equipment at


telecom site due to it removes the entire
drawback which we discussed above. At site
we use site master of Bird electronics (USA)
Ex-25000 that is more reliable & user friendly
as well as easy to operate.
It is used in site at least two times one at
Finalization & acceptance test (AT).

Advantageous of site analyzer


It does not require BTS to measure the VSWR due to it has
own power.
It gives graphical representation of measured value.
It supports the wide range of frequency.
We can save the readings and traces up to 500.
We can recoil save traces and compare with new reading.
We can import & export with PC by Site analyzer PC tool.
We can print out the trace directly by site master.
It operates on reachable battery.
Night vision mode present in it.
We can take multiple values for single trace.
The frequency range of it is780-2500MHz

Measurement by site master


VSWR with respect to frequency
VSWR with respect to distance
Forward power
Reflected power
Cable loss
Return loss

Requirement
Calibration kit
Frequency band
Sensor
Element of 50W & 5W according to band
9-oin Rs-232 serial straight cable
1\2M-7\8F adaptor

How it looks like


ON\
OFF

Display
1

ESC

Night mode

How to use site mater


It is widely used in measurement of VSWR,
position of fault, which kind of frequency must
be reflected back & power measurement.
There are following steps are given below, by
which we check VSWR if it is high, we find the
location of fault & rectify them then further
check the VSWR, if it is ok then save the trace.
The following steps are allowed to check
VSWR & Fault location. There are there modes
in it.

Modes
Measure match mode
Fault location mode
Measure power mode

Processes
1-Press ON\OFF button, wait for 20-30 seconds.
Fault location
Save\Recall
Auto scale

VSWR

Hold

Distance (Met.)

50

2-Display shows the fault location, but VSWR is always checking in measure match mode only.
So press mode button screen will change to

Select mode
Measure match
Fault location
Measure Power

3- Select measure match & press button in front of measure match here VSWR with respect to
frequency is measured. The screen will change than

Measure Match

Auto Scale

VSWR

Save\Recall

Hold

1710

Frequency (MHz

1880

4-Right now the frequency range is 1710-1880 MHz(1800 band),& our requirement is
890-960MHz (900 band) so we have change the frequency range. For it we press the configuration button
then screen will change to

Frequency
Unit

Select Frequency that gives

Start

890

Stop

960

Select start frequency by using left\right arrow keys or by typing on numeric key pads & press
Enter.
Select stop frequency by left\right arrow keys or by typing on numeric key pads & press Enter.
Press escape ESC
Now screen will change here.

Measure Match

Save\Recall

Hold

VSWR

Auto Scale

890

Frequency (MHz)
Calibration off

960

5-Once we change frequency calibration of site mater goes off automatically. Before taking
measurement calibrate the site master in new frequency band.
6-To calibrate the site master, we have to used calibration kit. That is shown below.

Load

Short

open

7-To calibrate press the calibration button. Screen will change to

Short
Open
Load

Calibration

Connect short of calibration kit with RF antennae port of site master &
press short button, a line appear on screen & screen change to
Calibration
Short Done
Open
Load

Here short done is appear in place of short, remove the short connector
from site mater & connect open connector with antennae port & press
open button. A line is appear on screen and screen change to
Calibration
Short Done
Open Done
Load

Remove the open connector & connect the load & press load button
After pressing load screen change & appear calibration full
Measure Match

Save\Recall

Hold

VSWR

Auto Scale

890

Frequency (MHz)
Calibration Full

960

8-Now calibration full appears on the screen; remove the load connector from site master.
Now we can measure of VSWR of our transmission line. Connect 1\2M To 7\8 adaptor
with RF port of site master. Remove both the cable from BTS in same sector.
Due to antennae is cross polarized; transmitted power from one cable may be
reflected back to the another. So remove both cables from BTS for safety reason.
One of them cable connect with adaptor & press Auto scale button, screen will change to

Measure Match
Save\Recall

Hold

VSWR

Auto Scale

Frequency (MHz)
890
Calibration Full

960

9- There is no marker on graph so we cannot take accurate reading of VSWR for it we


activate the maker (up to 6), for we press the marker button, the screen will change to

Select Marker
M1
off

We press the activate button for active Marker M1 & press ESC,the screen will
change to

Measure Match
Save\Recall

Hold

VSWR

Auto Scale

Frequency (MHz)
890

960

Calibration Full

That value of VSWR is not highest and accurate, for obtaining exact value & highest we sift the marker by
arrow keys.

Highest point of VSWR

Sift the marker left to right

After choosing upward arrow


marker sift to highest value
of VSWR, then it looks like

Least value of VSWR

Measure Match
Save\Recall

Hold

VSWR

Auto Scale

Frequency (MHz)
890
Calibration Full

M 1= 945 MHZ,

1.45

960

After getting exact value of VSWR, we find where the fault is?
10-For changing mode we press the Mode button & select fault location, the
screen will change to
Fault location
Save\Recall
Auto scale

VSWR

Hold

Distance (Met.)

450

11-In above scale distance is not accordance with ours, so distance


should be change, for it we press configuration button then screen will
be changed

Distance
Unit

Press distance, screen will change to

Start

Stop

50

Max.

450

Select start or stop section by using left \right arrow keys or pressing numeric keys.
Note: Distance scale should be more than the length of the transmission line normally;
it should be 5 meter more than the total length of transmission line.

Press the Enter & ESC screen will change to

Fault location
Save\Recall
Auto scale

VSWR

Hold

Distance (Met.)

50

Press auto scale button to find fault location the screen will change to

Fault location

Auto scale

VSWR

Save\Recall

Hold

Distance (Met.)

50

There is no marker on graph so we cannot take accurate reading of Fault for this we
activate the maker (up to 6), for we press the marker button, then marker is appear on
the graph anywhere, for obtaining the exact fault position, by using up arrow we obtain
fault in term of distance. Distance is taken from top of BTS end

Fault location

Auto scale

VSWR

Save\Recall

Hold

Distance (Met.)
M 1= 42.5 M ,

50

1.45

By using fault location we can only localize the fault. We do not measure VSWR only in measure
match mode

12- It is clear from graph fault is located nearby antennae port. Go to their end & check what
kind of fault is there & rectify them.
Again check the VSWR in Measure match mode only, if VSWR is
within limit then it is OK otherwise you further go to in fault location & recheck the new fault
location then further rectify them. The corrective action accordingly till the fault is completely
rectified.
13- Now we want to save the trace, before savings we press the auto scale button 2 or 3 times for
refreshing the trace for it press Save\Recall button then screen will change to

Save
Recall

Edit
Delete

The above screen appear now on selecting Save the screen will change to

A
B
C
D
E

A
B
C
D
E

F
G
H
I
J

K
L
M
N
O

P
Q
R
S
T

U
V
W
X
Y

Z
)
(
=
@

TECH-VIDHYA- 1M

P
Q
R
S
T

After entering a desired name press "Enter Key

TECH-VIDHYA - 1M
Save
Recall

TECH-VIDHYA - 1D

Edit
Delete

TECH-VIDHYA - 2M

To get last mode press ESC KEY