Date:
Authorized Inspector:
Date:
Vertical
217
N/A
A-250429-A1A-1A Rev.6
14
2014
(CRN)
(Drawing number)
(Year built)
N/A
None
SA 516M Gr.415N
10mm
3mm
1372mm
(Nominal thickness)
(Corr. allow.)
(Inner diameter)
7067
[Length (overall)]
No.
Type
ID
OD
Upper
1396
1538
113
SA 105M N
Lower
1400
1538
113
SA 105M N
7. Seams
Material
How Attached
Location
Bolting Material
1" UNC
Washer
(OD, ID, thk)
Spot
85%
N/A
N/A
Spot
(Eff., %)
(H.T. temp.)
(Time, hr)
[R.T. (spot
or full)]
SA 516M Gr.415N HT
85
SA 516M Gr.415N HT
(b) Material
Washer Material
Location (Top,
Bottom, Ends)
Minimum
Thickness
Corrosion
Allowance
Crown
Radius
(a)
Top
N/A
N/A
2:1
N/A
N/A
N/A
Concave
(b)
Bottom
10
N/A
N/A
2:1
N/A
N/A
N/A
Concave
Knuckle
Radius
Elliptical
Ratio
Conical
Apex Angle
Hemispherical
Radius
Flat
Diameter
Side to Pressure
(Convex or Concave)
Type
ID
OD
Material
How Attached
Washer
(OD, ID, thk)
Bolting Material
Washer Material
N/A
(b)
N/A
9. MAWP
0.601Mpa
F.V
(Internal)
-29C
N/A
0.601 Mpa
at
150C
at max. temp.
(External)
F.V
(Internal)
(External)
0.7812 Mpa
Material
Nozzle Thickness
Diameter
or Size
Type
Nozzle
Flange
Nom.
Corr.
A-Vapour Recycle
DN-200
Cl150WN
SA 106M Gr.B
SA 105M N
12.70
B- PSV 806
DN-50
CL300W
SA 106M Gr.B
SA 105M N
8.74
C-Inlet
DN-250
D-Vapour Inlet
DN-250
Cl150WN
SA 106M Gr.B
SA 105M N
15.09
E, F, G & H
DN-50
CL300W
SA 106M Gr.B
SA 105M N
8.74
Intergral
UW16.1(C)
...
...
I-Pump Drain
DN-150
Cl150WN
SA 106M Gr.B
SA 105M N
10.97
Intergral
UW16.1(C)
...
...
J-Drain
DN-50
CL300W
SA 106M Gr.B
SA 105M N
8.74
Intergral
UW16.1(C)
...
...
Yes
(Yes or no)
Lugs
No
(Number)
Legs
No
(Number)
Other
(Describe)
Reinforcement
Material
Attachment Details
No.
Nozzle
UW16.1(C)
Attached
Flange
Location
(Insp. Open.)
Note-8
Shell
...
...
Note-8
...
Note-9
(Where and how)
12. Remarks: Manufacturers Partial Data Reports properly identified and signed by Commissioned Inspectors have been furnished for the following
items of the report:
N/A
(Name of part, item number, Manufacturers name and identifying stamp)
(04/14)
14
Date:
Authorized Inspector:
Date:
Vessel constructed by
Co. name
Signed
(Representative)
.
I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by
One Beacon America Insurance Company, Lynn, MA
(04/14)