Sei sulla pagina 1di 9

SIB 1

SIB 1 is a PLMN scope SIB, which means that some parts of SIB 1 information can be retained even after
the cell reselection (if PLMN is the same in the new cell). SIB 1 contains the GSM-MAP cell NAS
information for each CN

SIB 3
SIB 3 contains the cell selection and reselection parameters for the serving cell. SIB 3 also contains the
cell access restriction information for the current cell. SIB 3 information is used by the RRC in idle mode
and connected mode (only if SIB 4 is not available),
to perform cell selection and reselection.
System Information Message (SIB 3)
Time : 15:25:42.453
Vendor Header
UARFCN : Not defined
SC : Not defined
sib4indicator : False
cellIdentity
Value : 6631337 (065 2FA9 hex)
cellSelectReselectInfo
cellSelectQualityMeasure : cpich-Ec-N0
modeSpecificInfo : fdd
s-SearchHCS : -105 dB
rat-List
RAT-FDD-InfoList :
[0 ] :
rat-Identifier : gsm
s-SearchRAT : 4 dB
s-HCS-RAT : 3 dB
s-Limit-SearchRAT : 0 dB
q-QualMin : -18
q-RxlevMin : -115 dBm
q-Hyst-l-S : 4 dB
t-Reselection-S : 2
maxAllowedUL-TX-Power : 21
cellAccessRestriction
cellBarred
CellBarred : notBarred
cellReservedForOperatorUse : notReserved
cellReservationExtension : notReserved
sysInfoType3-v4b0ext
sysInfoType3-v590ext
sysInfoType3-v5c0ext
sysInfoType3-v670ext
domainSpecificAccessRestrictionParametersForPLMNOfMIB
cSDomainSpecificAccessRestriction
DomainSpecificAccessRestriction-v670ext : noRestriction
pSDomainSpecificAccessRestriction

DomainSpecificAccessRestriction-v670ext : noRestriction

SIB 4
SIB 4 contains the same information as SIBs 3, but SIB 4 is used in connected states of the the RRC and
if not scheduled in a cell, the RRC shall use SIB 3 instead.

SIB 5
SIB 5 contains parameters for common physical channels such as PRACH, SCCPCH, etc.
These parameters are used in the establishment of channels in idle mode or connected
states, except CELL DCH.

SIB 7
SIB 7 contains fast changing parameters, particularly relating to RACH usage.
System Information Message (SIB 7)
Time : 15:25:42.671
Vendor Header
UARFCN : Not defined
SC : Not defined
modeSpecificInfo : fdd
ul-Interference : -102
prach-Information-SIB5-List
DynamicPersistenceLevelList :
[0 ] : 1

SIB 11
SIB 11 contains measurement control information and the neighbour cell information list.

SIB 12 contains the same information as SIB 11 but is only to be read and used in connected
mode.
System Information Message (SIB 12)
Time : 15:25:42.671
Vendor Header
UARFCN : Not defined
SC : Not defined
fach-MeasurementOccasionInfo
fACH-meas-occasion-coeff : 4
inter-freq-FDD-meas-ind : False
inter-freq-TDD-meas-ind : False
inter-RAT-meas-ind :
[0 ] : gsm
measurementControlSysInfo
use-of-HCS : hcs-not-used
cellSelectQualityMeasure : cpich-Ec-N0
trafficVolumeMeasSysInfo
trafficVolumeMeasurementObjectList
TrafficVolumeMeasurementObjectList :
[0 ] :
UL-TrCH-Identity : rachorcpch
trafficVolumeMeasQuantity
TrafficVolumeMeasQuantity : rlc-BufferPayload
trafficVolumeReportingQuantity
rlc-RB-BufferPayload : True
rlc-RB-BufferPayloadAverage : False
rlc-RB-BufferPayloadVariance : False
measurementValidity
ue-State : all-But-Cell-DCH
measurementReportingMode
measurementReportTransferMode : acknowledgedModeRLC
periodicalOrEventTrigger : eventTrigger
reportCriteriaSysInf
TrafficVolumeReportCriteriaSysInfo : trafficVolumeReportingCriteria
trafficVolumeReportingCriteria
transChCriteriaList
TransChCriteriaList :
[0 ] :
ul-transportChannelID
UL-TrCH-Identity : rachorcpch
eventSpecificParameters :
[0 ] :

eventID : e4a
reportingThreshold : th256
pendingTimeAfterTrigger : ptat0-5