Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
info
1. DESIGN DATA.
Design service moment
Ms
35.0 kN.m
56.0 kN.m
20.0 kN
500.0 mm
Thickness of slab
300.0 mm
Grade of concrete
D
fcu
35 N/mm2
Grade of reinforcement
fy
415 N/mm2
Ec
3.0E+04 N/mm2
Es
3.0E+05 N/mm2
50 mm
0.10 mm
D-c-(Dia/2)
=
=
242
mm
M / bd2fcu
0.055
226
=
=
230
mm
M / 0.95 fy z
628
mm2
Diameter
16
mm
Spacing
150
mm
670
mm2
1.07
V / bvd
0.17
2.0 DESIGN
2.1 DESIGN FOR FLEXURE.
Effective depth
k
z
z - Max.
(As)req.
(As)Prov.
Safety index
670
628
mm
> 1
OK
0.8[Sqrt(fcu.)]
N/mm2
<
4.7
N/mm2
0.8[sqrt(fcu.)] & 5 N/mm2
100As / bd
0.554
(400/d)
1.65
1.65
0.66
>
Therefore 400/d
Design concrete shear stress
vc
N/mm2
Steel ratio
150
mm
(As)Prov. / bd
0.0055
OK
http://www.civildesignhelp.info
Modular ratio
ae
=
=
Es / (Ec/2)
3.0E+05
###
20.00
ae * r
X /d
0.111
ae*r {[(1+ (2 /ae*r)]0.5 - 1}
0.373
90.2
Lever arm
d - X/3
mm
=
Concrete compressive stress
fcb
211.9
mm
2M
/
Z
b
X
=
s
=
fs
N/mm2
7.3
Ms / Z As
246.4
N/mm2
0.45 fcu
15.8
fcb
0.8 fy
N/mm2
332.0
fs
N/mm2
fcb'
>
Allowable tensile stress in steel
fs'
=
=
>
E1
=
=
=
Em
Acr
Crack width
OK
OK
(h-x) * fs
(d-x) * Es
1.14E-03
bt * (h-x) * (a' - x)
3*Es * As * (d-x)
2.40E-04
E1 - Stiffening effect of concrete
8.949E-04
86.8
mm
3 * Acr * Em
1+2[(Acr-Cmin.) / (h-x)]
0.173
mm
<
OK
Safety index
Astmin
195
mm2/m
Diameter
12
mm
Spacing
150
mm
377
mm2
1.93
377
195
> 1
OK