Siemens Vacuum Recloser 3AD


Medium-Voltage Equipment
Selection and Ordering Data

www.siemens.com/energy

R-HG11-172.tif

Siemens Vacuum Recloser 3AD

Siemens HG 11.42 2008

Siemens Vacuum Recloser 3AD

Siemens Vacuum
Recloser 3AD
Medium-Voltage Equipment
Catalog HG 11.42 2008

Contents

Contents

Page

Description

General

Switch unit

Controller, protection functions

Ambient conditions, altitude correction factor


and number of operating cycles

13

Product range overview and scope of delivery

14

Product Selection

15

Ordering data and configuration example

16

Selection of primary ratings

17

Selection of controller

20

Selection of additional equipment

24

Technical Data

27

Electrical data, dimensions and weights:


Voltage level 12 kV

28

Voltage level 15.5 kV

28

Voltage level 27 kV

29

Voltage level 38 kV

29

Annex

33

Inquiry form

34

Configuration instructions

35

Configuration aid
Foldout page

Siemens AG 2008

Siemens HG 11.42 2008

R-HG11-300.tif

Siemens Vacuum Recloser 3AD

Siemens HG 11.42 2008

Siemens Vacuum Recloser 3AD

Description
Contents

Contents

Page

Description

General

Switch unit:
Recloser principle

Design

Pole assemblies

Operating mechanism

Magnetic actuator

Mechanical lockout

Recloser cycle

R-HG11-301.tif

Controller:

Vacuum recloser with cubicle and controller

User interface

Protection functions

10

Communications

11

Protocols

11

Metering functions

11

Data records

11

Software

12

Standards

12

Ambient conditions

13

Altitude correction factor

13

Number of operating cycles

13

Product range overview

14

Scope of delivery

14

Siemens HG 11.42 2008

Siemens Vacuum Recloser 3AD

Description
General

Siemens vacuum recloser 3AD

Switch unit

Controller inside the cubicle

R-HG11-303.tif

The recloser consists of two main components: The


switch unit being the circuit-breaker and the controller as
protection and control unit. It is housed inside the control
cubicle.

R-HG11-302.tif

3AD vacuum reclosers are outdoor circuit-breakers


designed for frequent opening and reclosing in case of
temporary faults. They fulfill this task automatically by
monitoring the line and operating autonomously.

The switch unit is the primary part of the recloser. It is


located on top of the pole to switch the overhead line.
It is permanently exposed to weather and environment.

Siemens HG 11.42 2008

As the heart of the recloser, the controller is located in a


cubicle at the bottom of the pole.

Siemens Vacuum Recloser 3AD

Description
Switch unit

Recloser principle
Reclosers are used in distribution systems of power supply
companies (utilities). Like circuit-breakers they are capable
of switching normal and fault currents. They are equipped
with sensors and a controller being the protection and
control device. In case of a line fault, they can break and
make several times, thus avoiding longer network interruptions due to temporary faults.

1
R-HG11-304.tif

As outdoor devices they are normally pole-mounted and


exposed to environment and weather. A recloser consists of
two components: The switch unit (circuit-breaker) and the
controller (inside the control cubicle), both connected
through a control cable.
Design
Switching operation
The vacuum switching technology, proven and fully
developed for more than 30 years, is the basis for the
vacuum interrupters.

Switch unit front view

Pole assemblies
Each vacuum interrupter is embedded in an epoxy-resin pole
made out of weather-proof cycloalyphatic resin. This enables
a small design as well as resistance against environmental
effects. The vacuum interrupter is vertically mounted inside
the pole, providing a long service life. Each recloser is equipped with an integrated current transformer. For special protection purposes, a resistive voltage sensor can also be
incorporated in the pole. The accuracy achieved in this way
is much higher than that of capacitive dividers.

The pole assemblies of the recloser are directly mounted on


the operating mechanism housing. Besides the complete
kinematics, it also accommodates the position indicator and
a mechanical operations counter. The operating mechanism
housing is made of mild steel with a special coating for outdoor applications. Optionally, a stainless-steel housing is
available.

R-HG11-305.tif

Operating mechanism

Switch unit rear view

The recloser is installed on the pole by means of a pole


mounting frame. Alternatively, the recloser can be mounted
directly on a frame for pad-mounting in substations.
Magnetic actuator

HG11-2728 eps

The recloser is operated by a magnetic actuator enabling the


recloser cycle, i.e. the high number of switching operations
within a short period of time. The actuator is a bi-stable
system, locked in the end positions by permanent magnets.
If not in operation, the magnet coils do not consume any
power. The operating force is transmitted to all three poles
through a mechanical coupling.

Structure of the switch unit

Siemens HG 11.42 2008

Siemens Vacuum Recloser 3AD

Description
Switch unit

Mechanical lockout
A mechanical lockout enables tripping independently on the
controller. If this handle is pulled, the recloser opens and is
simultaneously locked out electrically and mechanically. The
handle stays extended, thus indicating the interlocked state.

To close the recloser again, the operating rod must first be


pushed back to the operation position in order to release the
lockout. Then the recloser can be closed electrically via the
control.
Recloser cycle
In case of a network fault, the recloser opens and recloses
several times. In case of temporary faults the automatic
reclosing significantly reduces the loss of power supply.
The recloser cycle is optimized accordingly:

R-HG11-306.tif

The first interruption of a fault is done quickly and


instantaneously, so that even the fuses in the system do not
operate. After approx. 300 ms (user settable), it recloses
back on.

Lock-out handle pushed in


(operational position)

The second and third interruption has a definite or inversetime delay. Thus, downstream fuses in the network have the
chance to operate and isolate the affected network section,
restoring normal operation in the remaining network. The
following dead time is usually 210 s (user settable).
The fourth (optional up to the fifth) interruption is fast
again and serves as a check. This for example utilizes the
physical effect that, when the short-circuit occurs, the lines
move due to the magnetic forces of the current, and foreign
objects are shaken off.

R-HG11-307.tif

If the fault still exists, the recloser turns to the lockout and
can only be closed from the operator panel or via SCADA.

Lock-out handle pulled


(open position)

Siemens HG 11.42 2008

Siemens Vacuum Recloser 3AD

Description
Controller

The controller
The Siemens Argus-M controller is based on the Argus-M
directional overcurrent protection relay. These relays provide
protection, control, monitoring, instrumentation and metering with integrated input and output logic, data logging
& fault reports.

The controller is mounted in the control cubicle. Along with


the controller, this cubicle also contains the auxiliary power
supply with batteries for uninterruptible power supply,
electronic boards, fuses, and a general-purpose outlet to
power a laptop.

R-HG11-308.tif

Communication access to relay functionality is via a front


USB port for local PC connection or a rear electrical RS485
port for remote connection. Additional rear port options are
available.

Argus-M controller

The controller contains a large number of protection


functions (elements) which can be selected or deselected
through the menu driven display. These elements can be
customized to the utilities needs by parameters (settings) as
described below.
User interface
20-character x 4-line backlit LCD
Menu navigation keys
3 fixed LEDs
8 or 16 programmable tri-color LEDs are available
eliminating the need for expensive panel-mounted pilot
lights and associated wiring. Each LED is tri-colored (red,
green, yellow) allowing for clear indication of the associated
functions state.

Each function key has an associated tri-color LED (red,


green, yellow) allowing for clear indication of the associated
functions state.

R-HG11-309.tif

12 programmable function keys each with tri-color LED are


available for implementing scheme control functionality.

Tri-color LEDs and pushbuttons


of the controller

Siemens HG 11.42 2008

Siemens Vacuum Recloser 3AD

Description
Controller

Protection functions
(in order of ANSI numbering)
37 Undercurrent

Each element has settings for pickup level and Definite Time
Lag (DTL) delays. Operates if current falls below setting for
duration of delay.
46BC Broken conductor/phase unbalance
Element has settings for pickup level and DTL delay. With the
circuit-breaker closed, if one or two of the line currents fall
below setting, this could be due to a broken conductor.
46NPS Negative phase-sequence overcurrent
Each element has user settings for pickup level and Inverse
Definite Minimum Time Lag (IDMTL) or DTL delay. It operates
if NPS current exceeds setting and delay. NPS current elements can be used to detect unbalances on the system or
remote earth faults when a delta-star transformer is in
circuit.
49 Thermal overload
The thermal algorithm calculates the thermal states from the
measured currents and can be applied to lines, cables and
transformers. Outputs are available for thermal overload and
thermal capacity.
50/51 Phase fault
50 INST (instantaneous)/DTL (Definite Time Lag) and
51 IDMTL (Inverse Definite Minimum Time Lag)/DTL elements provide overcurrent protection, each with independent settings for pickup current, time-multiplier (51) and
time delays. The user can select IEC or ANSI time current
characteristics. The IDMT stage has a user programmable
reset characteristic, either DTL or shaped current/time reset
characteristic to improve grading with electromechanical
protection.
50G/51G/50N/51N Earth fault/sensitive earth fault
Earth-fault current is derived from the residual connection of
the 3 integrated line CTs. 50 INST/DTL and 51 IDMTL/DTL
elements provide overcurrent protection, each with independent settings for pickup current, time-multiplier (51) and
time delays. The user can select IEC or ANSI time current
characteristics. The IDMT stage has a user programmable
reset characteristic, either DTL or shaped current/time reset
characteristic to improve grading with electromechanical
protection.
50BF Circuit-breaker fail
The circuit-breaker fail function is triggered from an internal
trip signal. Line currents are monitored following a trip signal
and an output is issued if any current is still detected after a
specified time interval. This can be used to re-trip the CB or
to back-trip an upstream CB. A second back-trip time delay is
available to enable another stage to be utilized if required.

10

Siemens HG 11.42 2008

64H Restricted earth-fault scheme


The measured earth-fault input may be used in a 64H high
impedance restricted earth-fault scheme. Required external
series stabilizing resistor and non-linear shunt resistor can be
supplied.
74TC Trip-circuit supervision
The trip-circuit(s) can be monitored via binary inputs. Tripcircuit failure raises an HMI alarm and output(s).
81HBL2 Inrush restrain/second harmonic block
Where second harmonic current is detected (i.e. during
transformer energization) user selectable elements can be
blocked.
Cold load pickup
If a circuit-breaker is closed onto a cold load, i.e. one that
has not been powered for a prolonged period, this can
impose a higher than normal load-current demand on the
system which could exceed normal settings. These
conditions can exist for an extended period and must not be
interpreted as a fault. To allow optimum setting levels to be
applied for normal operation, the cold load pickup feature
will apply alternative settings for a limited period. The feature resets when either the circuit-breaker has been closed
for a settable period, or if the current has been reduced
beneath a set level for a user set period.
27/59 Under/overvoltage
Each element has settings for pickup level, drop-off level and
Definite Time Lag (DTL) delays. It operates if voltage exceeds
setting for duration of delay. It can be applied in load shedding schemes.
47 Negative phase-sequence overvoltage
Each element has settings for pickup level and Definite Time
Lag (DTL) delays. It operates if NPS voltage exceeds setting
for duration of delay.
59N Neutral overvoltage
Each element has settings for pickup level and Definite Time
Lag (DTL) delays. It operates if neutral voltage exceeds
setting for duration of delay. Neutral overvoltage can be
used to detect earth faults in high impedance earthed or
isolated systems.
60CTS CT supervision
The CT supervision considers the presence of negative
phase-sequence current, without an equivalent level of
negative phase-sequence voltage, for a user set time as a
CT failure. The element has user operate and delay settings.

Siemens Vacuum Recloser 3AD

Description
Controller

67/67N Directional control

Metering functions

Phase-fault, earth-fault and sensitive earth-fault elements


can be directionalized. Each element can be user set to
forward, reverse, or non-directional. Directional phase-fault
elements are polarized from quadrature voltage. Earth-fault
elements can be user set to be polarized from residual
voltage or negative phase-sequence voltage.

Primary current phases and earth

81 Under/overfrequency

Binary input/output status

Each element has settings for pickup level, drop-off level and
Definite Time Lag (DTL) delays. It operates if frequency exceeds setting for duration of delay. It is typically applied in
load shedding schemes.

Trip circuit healthy/failure

79 Auto-reclose

Event records

Each element provides independent phase-fault and earthfault/sensitive earth-fault sequences of up to 5 trips, i.e.
4 reclose attempts before lockout. Auto-reclose sequence
can be user set to be initiated from internal protection
operation or via binary input from an external protection.
Each trip in the sequence can be user set to be either instantaneous (fast) or delayed. The user can set each reclose
(dead) time and the reclaim time.

Frequency

Secondary current phases and earth


Positive phase-sequence (PPS) current

Negative phase-sequence (NPS) current


Zero phase-sequence (ZPS) current

Time and date


Starters
Fault records

Waveform records
Circuit-breaker trip counters
It summation for contact wear
Direction
Primary line and phase voltages
Secondary voltages

Battery and capacitor check (no number)


Sag/swell detection
Optional protection functionality
Sync check
Fault locator
Loop automation
Single-triple operation

Communications
Front USB port
Rear RS485 port

Optional functions
Rear fiber optic ports
IRIG-B ports

Apparent power and power factor


Real and reactive power
W Hr forward and reverse
VAr Hr forward and reverse
Historical demand record
Positive phase-sequence (PPS) voltage
Negative phase-sequence (NPS) voltage
Zero phase-sequence (ZPS) voltage

Data records
Sequence of event records
Up to 5000 events can be stored.
Fault records

RS232 ports

The last 10 fault records are displayed on the HMI, with time
and date of trip, measured quantities and type of fault.

Protocols

Disturbance recorder

IEC 60870-5-103

The waveform recorder stores analog data for all phases, the
states of protection functions, binary inputs, LEDs and binary
outputs with pre & post trigger data. A record can be triggered
from protection function, binary input or via data communications. The waveform recorder stores up to 10 s data.

Modbus RTU
DNP 3.0

Load profile recording


A rolling record of demand over the last 24 h is stored. The
demand is averaged over a user selectable period of time.
A rolling record of such demand averages is stored and
provides the demand history. A typical application is to
record 15 min-averages for the last 7 days.
Siemens HG 11.42 2008

11

Siemens Vacuum Recloser 3AD

Description
Controller, standards

Software
Reydisp Evolution
For communication with the relay via a PC (personal
computer) a user-friendly software package, Reydisp
Evolution, is available to allow transfer of relay settings,
waveform records, event records, fault data records,
instruments/meters and control functions. Reydisp Evolution
is compatible with IEC 60870-5-103.

R-HG11-310.tif

Programmable logic

Typical Reydisp Evolution screenshot

The user can map binary inputs and protection operated


outputs to function inhibits, logic inputs, LEDs and/or binary
outputs. The user can also enter up to 16 equations defining
scheme logic using standard functions e.g. timers and/or
gates, inverters and counters. Each protection element
output can be used for alarm & indication and/or tripping.
Waveform records analysis
See figure left
Quick logic
The Quick logic feature allows the user to input up to 16
logic equations (E1 to E16) in text format. Equations can be
entered using Reydisp or at the relay fascia.
Each logic equation is built up from text representing control
characters. Each can be up to 20 characters long.
Standards
The recloser conforms to the following standards
ANSI C37.60 (2003)
IEC 60255
IEC 60694 (in future IEC 62271-1)

12

Siemens HG 11.42 2008

Siemens Vacuum Recloser 3AD

Description
Ambient conditions, altitude correction factor and number of operating cycles

Ambient conditions
The recloser is designed for the normal operating conditions
defined in ANSI C37.60. This comprises an ambient temperature from 40 C to +55 C plus solar radiation.

55C

Altitude correction factor


The dielectric strength of air insulation decreases with
increasing altitude due to low air density. The rated lightning
impulse withstand voltage values specified in the chapter
Technical Data apply to a site altitude of 1000 m above sea
level. For an altitude above 1000 m, the insulation level
must be corrected according to the opposite drawing.

max. 95% per day


max. 90% per month

HG11-2515a_en eps

-40C

The characteristic shown applies to the rated short-duration


power-frequency withstand voltage and the rated lightning
impulse withstand voltage.

1.50

Rated withstand voltage under standard reference atmosphere

U0

Rated withstand voltage requested for the place of installation

Ka

Altitude correction factor according to the opposite diagram

Example
For a requested rated lightning impulse withstand voltage
of 75 kV at an altitude of 2500 m, an insulation level of
90 kV under standard reference atmosphere is required as
a minimum:
90 kV W 75 kV x 1.2

1.40

1.30

1.20
HG11-2517c_en eps

U W U0 x Ka

Altitude correction factor

To select the devices, the following applies:

1.10

1.00
1000

1500

2000

2500

3000 3500 m 4000


Site altitude

Number of operating cycles


The recloser is designed for 10,000 operating cycles at
normal current.
According to the standard IEEE C37.60, the recloser has been
tested for 116 short-circuit breaking operations. The actual
number of short-circuit breaking operations is higher than
that, and can be even more than 200 depending on the parameters of the short-circuit current (amplitude, DC component).

Siemens HG 11.42 2008

13

Siemens Vacuum Recloser 3AD

Description
Product range overview and scope of delivery

Product range overview


Rated voltage

Rated
short-circuit
breaking current

Rated
lightning impulse
withstand voltage

kV

kA

kV

12
15.5

12.5
12.5
16
12.5
12.5
16
12.5
16

27

38

Rated normal current

400 A

95
110
110
125
150
150
170
170

n
n
n

630 A

800 A

n
n
n
n
n
n
n
n

n
n
n
n
n
n
n
n

Scope of delivery
Standard equipment

Switch unit
Operating mechanism
Operating mechanism
housing
Switching medium
Insulation
Power supply
Position indicator
Operations counter
Interlocking
Configuration
Sensors
Controller and
control cubicle
Cubicle
Socket outlet
Controller size
Number of inputs/
outputs for customer use
Temperature range
Control keys
Controller interfaces

14

Siemens HG 11.42 2008

Electrical operating mechanism


(magnetic actuator)
Mild steel with outdoor protection
coating IP 55 with lifting eyes
and earthing connection
Vacuum interrupters
Cycloaliphatic epoxy resin/air
Auxiliary power input
OPEN: green
CLOSED: red
Mechanical in the switch unit;
electronical in the controller
Electrical; mechanical lockout
Pole mounting and 6 m
control cable
Integrated current transformers

Mild steel with outdoor protection


coating IP 65 with lifting eyes
and earthing connection
USA version
E10 (= 10" width)
5 x BI, 8 x BO
12 function keys
8 user-definable LEDs
Up to 30 C
5 navigation keys,
12 function keys,
2 pushbuttons
USB (front), RS485 (rear)

Optional available

Remarks

Stainless steel

Auxiliary transformer for supply


from HV line
Customer-specific color or inscription

Other cable lengths and/or


substation frame
Integrated voltage sensors

Stainless steel
Country-specific design
E12 (= 12" width)
Additional BI/BO and 12 LEDs
40 C
Customer-specific pushbuttons or
rotary CLOSE/OPEN switches
RS232, fiber optic, IRIG-B

Siemens Vacuum Recloser 3AD

Product Selection
Contents

Contents

Page

Product Selection

15

Ordering data and configuration example

16

Selection of primary ratings:


Voltage level 12 kV

17

Voltage level 15.5 kV

17

Voltage level 27 kV

18

Voltage level 38 kV

19

R-HG11-311.tif

Selection of controller:
20

Current and voltage measuring

20

Controller size

21

Auxiliary voltage

21

Control and sensor cables

22

Communication protocols

22

Communication interfaces

22

Function packages

23

Languages and power socket

23

Selection of additional equipment

24

Accessories and spare parts

25

R-HG11-312.tif

Switch unit bottom view

Recloser configuration

Control cubicle

Siemens HG 11.42 2008

15

Siemens Vacuum Recloser 3AD

Product Selection
Ordering data and configuration example

Order number structure

Mounting parts and special versions ( )

The vacuum reclosers consist of a primary part as well as of a


controller or secondary part. The relevant data make up the
16-digit order number. The primary part covers the main
electrical data of the circuit-breaker poles. The controller and
secondary part covers all auxiliary devices and the controller,
which are necessary for operating and controlling the
recloser.

In case of special versions, - Z is added to the order number


and a descriptive order code follows. If several special
versions are required, the suffix - Z is only listed once.
If a requested special version is not in the catalog and can
therefore not be ordered via order code, it has to be
identified with Y 9 9 after consultation. The agreement
hereto is made between your responsible sales partner and
the order processing department in our Switchgear Factory
in Berlin.

Order codes
Individual equipment versions, marked with 9 or Z in the 8th
to 16th position, are explained more in detail by a 3-digit
order code. Several order codes can be added to the order
number in succession and in any sequence.

a: alphabetical
Position:

Order No.:
1st position

n: numerical

10 11 12

13 14 15 16

3 A D n

Order codes

n n n

Primary part
Superior group
Switching devices

2nd position

Main group
Circuit-breaker

3rd position

Subgroup
Outdoor vacuum recloser

4th to 7th position

Basic equipment
Design and ratings
of the vacuum recloser

8th to 16th position

Secondary part
Controller, sensors, cables and
other necessary data
Order codes
Group of 3 after the Order No.
Format: a n a

Special versions ( )
Initiated with -Z
Group of 3 after the Order No.
Format: a n n

Configuration example
In order to simplify the selection of the correct order number
for the requested recloser type, you will find a configuration
example on each page of the chapter Equipment Selection.
For the selection of the auxiliary voltages, the fixing options,
the controller, etc. always the last example of the primary
part was taken over and continued, so that at the end of the
equipment selection (page 24) a completely configured
recloser results as an example.

Example for Order No.:


Order codes:

16

Siemens HG 11.42 2008

On the foldout page we offer a configuring aid.


Here you can fill in the order number you have
determined for your recloser.

3 A D 6

n n n n n

n n n n

Siemens Vacuum Recloser 3AD

Product Selection
Selection of primary ratings

12 kV

Position:

Order No.:

50/60 Hz

3 A D

n n n n

n n n n n

10 11 12

3
3
3
3
3
3
3
3

A
A
A
A
A
A
A
A

D
D
D
D
D
D
D
D

1
3
4
6
1
3
4
6

1
1
1
1
1
1
1
1

2
2
2
2
2
2
2
2

2
2
2
2
3
3
3
3

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A

D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D

1
3
4
6
1
3
4
6
1
3
4
6
1
3
4
6
1
3
4
6

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

2
2
2
2
2
2
2
2
2
2
2
2
3
3
3
3
3
3
3
3

1
1
1
1
2
2
2
2
3
3
3
3
2
2
2
2
3
3
3
3

3 A D 6

13 14 15 16

n n n n

Order codes

n n n

kV

kV

kV

kA

12

75

42

12.5

630

800

See page 24

See page 23

See page 23

See page 22

See page 22

See page 22

See page 21

See page 21

See page 20

Ir

See page 20

Rated normal current

Isc

Three-phase for
loop automation

Rated short-circuit
breaking current

Ud

3 x single-phase/
single-triple

Rated short-duration
power-frequency
withstand voltage

Up

Three-phase

Rated lightning impulse


withstand voltage

Ur

Single-phase

Rated voltage

Type

15.5 kV
50/60 Hz
Ur

Up

Ud

Isc

Ir

kV

kV

kV

kA

15.5

110

50

12.5

400

630

800

16

630

800

Configuration example
Siemens vacuum recloser 3AD
Rated voltage Ur = 15.5 kV
Rated lightning impulse withstand voltage Up = 110 kV
Rated short-duration power-frequency withstand voltage Ud = 50 kV
Rated short-circuit breaking current Isc = 16 kA
Rated normal current Ir = 630 A
Type: Three-phase recloser for loop automation
Example for Order No.:
Order codes:

3 A D

n n n n n

n n n n
Siemens HG 11.42 2008

17

Siemens Vacuum Recloser 3AD

Product Selection
Selection of primary ratings

27 kV

Position:

Order No.:

50/60 Hz

n n n n

n n n n n

kV

kV

kA

125

60

12.5

400

630

800

60

12.5

400

630

800

16

630

800

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

1 3 2 1
3 3 2 1
4 3 2 1
6 3 2 1
1 3 2 2
3 3 2 2
4 3 2 2
6 3 2 2
1 3 2 3
3 3 2 3
4 3 2 3
6 3 2 3
On request
On request
On request
On request
On request
On request
On request
On request
On request
On request
On request
On request
On request
On request
On request
On request
On request
On request
On request
On request

Configuration example
Siemens vacuum recloser 3AD
Rated voltage Ur = 27 kV
Rated lightning impulse withstand voltage Up = 125 kV
Rated short-duration power-frequency withstand voltage Ud = 60 kV
Rated short-circuit breaking current Isc = 12.5 kA
Rated normal current Ir = 400 A
Type: Three-phase
Example for Order No.:
Order codes:
Siemens HG 11.42 2008

A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A

D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D

10 11 12

13 14 15 16

n n n n

Order codes

n n n

3 A D

3 A D 3

n n n n n

n n n n

See page 24

See page 23

See page 23

See page 22

See page 22

See page 22

See page 21

See page 21

See page 20

See page 20

Rated normal current

kV
27

Three-phase for
loop automation

Rated short-circuit
breaking current

Ir

3 x single-phase/
single-triple

Rated short-duration
power-frequency
withstand voltage

Isc

Three-phase

Rated lightning impulse


withstand voltage

Ud

Single-phase

Rated voltage

Up

18

Type

Ur

150

3 A D

Siemens Vacuum Recloser 3AD

Produt Selection
Selection of primary ratings

38 kV

Position:

Order No.:

50/60 Hz

3 A D

n n n n

n n n n n

10 11 12

13 14 15 16

n n n n

Order codes

n n n

kV

kV

kV

kA

38

170

70

12.5

630

800

16

630

800

Configuration example
Siemens vacuum recloser 3AD
Rated voltage Ur = 38 kV
Rated lightning impulse withstand voltage Up = 170 kV
Rated short-duration power-frequency withstand voltage Ud = 70 kV
Rated short-circuit breaking current Isc = 16 kA
Rated normal current Ir = 800 A
Type: Single-phase
Example for Order No.:
Order codes:

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A

D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D

See page 24

See page 23

See page 23

See page 22

See page 22

See page 22

See page 21

See page 21

See page 20

Ir

See page 20

Rated normal current

Isc

Three-phase for
loop automation

Rated short-circuit
breaking current

Ud

3 x single-phase/
single-triple

Rated short-duration
power-frequency
withstand voltage

Up

Three-phase

Rated lightning impulse


withstand voltage

Ur

Single-phase

Rated voltage

Type

On request
On request
On request
On request
On request
On request
On request
On request
On request
On request
On request
On request
On request
On request
On request
On request

3 A D

on request
3 A D

n n n n n

n n n n
Siemens HG 11.42 2008

19

Siemens Vacuum Recloser 3AD

Product Selection
Selection of controller

Options

Recloser for pole mounting 1) incl. cubicle, controller and control cable
Recloser for substation application incl. cubicle and controller
Switch unit only (w/o cubicle, controller and control cable) 2)

10 11 12

n n n n n

1
2
3

13 14 15 16

n n n n

1) Pole mounting according to list of accessories


2) This option is only possible in the stated order number

9th position
Current and voltage measuring
Current transformers
1 integrated CT
per pole

Voltage sensors
1 integrated sensor
per pole
(including sensor cables)

n
n
n 1)

n
n 1)

3 x external VTs
(to be defined as
accessories)
A
B
C

n 1)

1) Necessary for recloser type: Three-phase for loop automation

Configuration example
Siemens vacuum recloser 3AD
3 A D
(Ur = 27 kV, Up = 125 kV, Ud = 60 kV, Isc = 12.5 kA, Ir = 400 A)
Type: Three-phase
3
Recloser for pole mounting incl. control cubicle and control cable
Current and voltage measuring: current transformers, 1 integrated CT per pole
Example for Order No.:
Order codes:

20

Siemens HG 11.42 2008

3 A D 3

1
A

1 A

n n n

n n n n

Order codes

n n n
See page 24

See page 23

See page 23

n n n n

See page 22

See page 22

See page 22

3 A D

See page 21

Position:

Order No.:

See page 21

8th position
Recloser configuration

Siemens Vacuum Recloser 3AD

Product Selection
Selection of controller

16

13

23

33

43

For 3-phase and single-phase applications

n
n
n

n
n

n
n
n
n
n

For loop automation

n
n
n

14

n
n

n
n

10 11 12

n n n n n

n
n

22

See page 22

13 14 15 16

n n n n

Order codes

n n n

30
A
B
C
D
E

n
n

See page 24

See page 23

n n n n

See page 23

See page 22

See page 22

3 A D

Number of binary outputs


(partly for customer use)

12

Number of binary inputs


(partly for customer use)

Function keys

E10 E12

Position:

Order No.:

Number of
tri-color LEDs

Controller size

10th position
Controller size

Without controller (refers to switch unit only)

11th position
Auxiliary voltage

DC voltage

AC voltage

Without auxiliary voltage supply (need for switch unit only)


48 V
60 V
110 V
220 V
110/120 V
220/240 V
With auxiliary transformer and rated voltage as below:
Rated voltage 11 kV
Rated voltage 12 kV
Rated voltage 13.8 kV
Rated voltage 15 kV

Configuration example
Siemens vacuum recloser 3AD
(Ur = 27 kV, Up = 125 kV, Ud = 60 kV, Isc = 12.5 kA, Ir = 400 A)
Type: Three-phase
Controller size: E12, 12 function keys,
16 tri-color LEDs, 33 binary inputs, 30 binary outputs
Auxiliary voltage 110/120 V AC
Example for Order No.:
Order codes:

0
On request
On request
3
4
5
6
9
9
9
9

With order code


With order code
With order code
With order code

T
T
T
T

3
3
3
3

A
B
C
D

3 A D
3

1 A
D
5

3 A D 3

1 A D 5

n n n n
Siemens HG 11.42 2008

21

Siemens Vacuum Recloser 3AD

Product Selection
Selection of controller

n n n n

10 11 12

n n n n n

13 14 15 16

n n n n

Options
(also comprises sensor cables for external voltage sensors if selected)

Without (need for switch unit only)


Cable length 6 m
Cable with special length (to be specified in clear text)

0
1
9

Options

Without communication protocol (need for switch unit only)


IEC 60870-5-103 and Modbus RTU
DNP 3.0

0
1
2

n
n

ST plug (multiple mode)

n
n
n
n

ST plug (single mode)

1 x RS232 (rear)

2 x optical

n
n

1 x IRIG-B

n
n

2 x RS485 (rear)

1 x RS485 (rear)

1 x USB (front)

14th position
Communication interfaces

n
n
n
n
n

A
B
C
D
E
Y

Without communication interface (need for switch unit only)

Configuration example
Siemens vacuum recloser 3AD
(Ur = 27 kV, Up = 125 kV, Ud = 60 kV, Isc = 12.5 kA, Ir = 400 A)
Type: Three-phase
Length of control and sensor cable 6 m
Communication protocol IEC 60870-5-103 and Modbus RTU
Communication interfaces 1 x USB, 2 x RS485, 1 x IRIG-B
Example for Order No.:
Order codes:

22

Siemens HG 11.42 2008

3 A D
3

1 A D 5
1

1
C

3 A D 3

1 A D 5

n n n

M 1

13th position
Communication protocols

Order codes

See page 24

3 A D

See page 23

Position:

Order No.:

See page 23

12th position
Control and sensor cables

n n

Siemens Vacuum Recloser 3AD

Product Selection
Selection of controller

15th position
Function packages

Position:

3 A D

n n n n

10 11 12

n n n n n

13 14 15 16

n n n n

Order codes

n n n
See page 24

Order No.:

Options

Standard protection and monitoring functions


Standard protection and monitoring functions
plus synchro-check and fault locator
Standard protection and monitoring functions
for loop automation
Standard protection and monitoring functions
for loop automation with synchro-check and fault locator
Standard protection and monitoring functions
for single-triple application
Standard protection and monitoring functions
for single-triple application with synchro-check and fault locator
Without protection functions (need for switch unit only)

A
C
D
E
F

G
Y

16th position
Languages and power socket
Language of operating
instructions and nameplate

Standard of power socket

English
American English
Spanish
Portuguese
Other languages on request

UK
USA
Mexico
Brazil

Configuration example
Siemens vacuum recloser 3AD
(Ur = 27 kV, Up = 125 kV, Ud = 60 kV, Isc = 12.5 kA, Ir = 400 A)
Type: Three-phase
Controller with standard protection and monitoring functions
Language of operating instructions and nameplate: English
Standard of power socket: UK
Example for Order No.:
Order codes:

1
2
3
4
9

3 A D
3

1 A D 5

C
A
1

3 A D 3

1 A D 5

C A

Siemens HG 11.42 2008

23

Siemens Vacuum Recloser 3AD

Product Selection
Selection of additional equipment

Selection of additional equipment

Position:

Order No.:

3 A D

n n n n

10 11 12

n n n n n

13 14 15 16

n n n n

Order codes

n n n

Z
Z
Z
Z
Z

A
F
T
T
T

3
0
0
0
0

8
2
1
2
3

Z
Z

F
T

0
0

2
1

Options

Ambient temperature down to 40 C


Seaworthy packing inside Germany
Stainless steel for tank, control cubicle
Radio modem power supply 12 V DC
Serial to Ethernet converter
Pole mounting frame with bracket for surge arrester
(source and load side)
Pole mounting frame Siemens design
(with bracket for surge arresters, source and load side)
Further non-listed special versions (only after consultation with
your responsible sales partner). Information additionally in clear text

Configuration example
Siemens vacuum recloser 3AD
3 A D
Rated voltage Ur = 27 kV
Rated lightning impulse withstand voltage Up = 125 kV
Rated short-duration power-frequency withstand voltage Ud = 60 kV
Rated short-circuit breaking current Isc = 12.5 kA
Rated normal current Ir = 400 A
Type: Three-phase
3
Recloser for pole mounting incl. control cubicle and control cable
Current and voltage measuring: current transformers, 1 CT integrated per pole
Controller size: E12, 12 function keys,
16 tri-color LEDs, 33 binary inputs, 30 binary outputs
Auxiliary voltage 110/120 V AC
Length of control and sensor cable 6 m
Communication protocol IEC 60870-5-103 and Modbus RTU
Communication interfaces 1 x USB, 2 x RS485, 1 x IRIG-B
Controller with standard protection and monitoring functions
Language of operating instructions and nameplate: English
Standard of power socket: UK
Seaworthy packing inside Germany
Stainless steel for tank, control cubicle
Example for Order No.:
Order codes:

24

Siemens HG 11.42 2008

1
A
D
5
1

C
A
1

3 A D 3
0

1 A D 5

C A

Siemens Vacuum Recloser 3AD

Product Selection
Accessories and spare parts

Accessories and spare parts


A wide range of spare parts and accessories is available.
Please contact your responsible sales partner and the order
processing department in our Switchgear Factory in Berlin.

HG11-2732_en eps

Data on the nameplate


Note:
For any request regarding spare parts,
subsequent deliveries, etc. the following
details are necessary:
Type designation
Serial No.
Design code
Year of manufacture

Siemens HG 11.42 2008

25

R-HG11-313.tif

Siemens Vacuum Recloser 3AD

26

Siemens HG 11.42 2008

Siemens Vacuum Recloser 3AD

Technical Data
Contents

Contents

Page

Technical Data

27

Electrical data, dimensions and weights:


28

Voltage level 15.5 kV

28

Voltage level 27 kV

29

Voltage level 38 kV

29

R-HG11-314.tif

Voltage level 12 kV

Switch unit driver - discarge switch for the capacitor

R-HG11-315.tif

Controller with protective cap

Siemens HG 11.42 2008

27

Siemens Vacuum Recloser 3AD

Technical Data

Rated short-circuit breaking current

Rated short-circuit making current

Rated lightning impulse withstand voltage

Rated short-duration
power-frequency withstand voltage

Voltage drop U between connections

Creepage distance, phase-to-earth

Clearance,
phase-to-phase

Minimum clearance,
phase-to-earth

Weight

Line charging current

Cable charging current

Ir

tk

Isc

Ima

Up

Ud

kA

kA

kV

kV

mV

mm

mm

mm

kg

12 kV
Rated normal current

50/60 Hz

Order No.

3AD123

3AD 122

15.5 kV
50/60 Hz

3AD222
3AD223
3AD232
3AD233

3AD 221

28

Siemens HG 11.42 2008

Rated operating sequence: O - 0.2s - CO 2s - CO - 2s - CO (-30s - CO) - Lock-out

Rated duration of short-circuit

Electrical data, dimensions and weights

630

12.5

31.5

75

42

24

810

312

287

142

10

800

12.5

31.5

75

42

24

810

312

287

142

10

Ir

tk

Isc

Ima

Up

Ud

kA

kA

kV

kV

mV

mm

mm

mm

kg

400

12.5

31.5

110

50

24

810

312

287

142

10

630

12.5

31.5

110

50

24

810

312

287

142

10

800

12.5

31.5

110

50

24

810

312

287

142

10

630

16

40

110

50

24

810

312

287

142

10

800

16

40

110

50

24

810

312

287

142

10

Siemens Vacuum Recloser 3AD

Technical Data

Rated short-circuit breaking current

Rated short-circuit making current

Rated lightning impulse withstand voltage

Rated short-duration
power-frequency withstand voltage

Voltage drop U between connections

Creepage distance, phase-to-earth

Clearance,
phase-to-phase

Minimum clearance,
phase-to-earth

Weight

Line charging current

Cable charging current

Ir

tk

Isc

Ima

Up

Ud

kA

kA

kV

kV

mV

mm

mm

mm

kg

27 kV
Rated normal current

50/60 Hz

Order No.

3AD322
3AD323
3AD ...
3AD
3AD
3AD
3AD

3AD 321

38 kV
50/60 Hz


3AD
3AD
3AD

3AD

Rated operating sequence: O - 0.2s - CO 2s - CO - 2s - CO (-30s - CO) - Lock-out

Rated duration of short-circuit

Electrical data, dimensions and weights

400

12.5

31.5

125

60

24

810

312

287

142

25

630

12.5

31.5

125

60

24

810

312

287

142

25

800

12.5

31.5

125

60

24

810

312

287

142

25

400

12.5

31.5

150

60

On request

25

630

12.5

31.5

150

60

On request

25

800

12.5

31.5

150

60

On request

25

630

16

40

150

60

On request

25

800

16

40

150

60

On request

25

3
Ir

tk

Isc

Ima

Up

Ud

kA

kA

kV

kV

mV

mm

mm

mm

kg

630

12.5

31.5

170

70

On request

40

800

12.5

31.5

170

70

On request

40

630

16

40

170

70

On request

40

800

16

40

170

70

On request

40

Siemens HG 11.42 2008

29

Siemens Vacuum Recloser 3AD

Technical Data
Dimension drawings

Dimension drawings

HG11-2729 eps

638
600

600

350

365

HG11-2730_en eps

615

10

962

250

597

Dimensions of control cubicle

460
520.5

Dimensions of switch unit

Mabild 2
Mabild 1

30

Siemens HG 11.42 2008

Siemens Vacuum Recloser 3AD

Technical Data
Dimension drawings

Dimension drawings

901

600

1341

962

407
357

1334

Mabild 2
HG11-2731 eps

425

1173

425

Dimensions of switch unit with pole mounting frame

Siemens HG 11.42 2008

31

R-HG11-181.tif

Siemens Vacuum Recloser 3AD

32

Siemens HG 11.42 2008

Siemens Vacuum Recloser 3AD

Annex
Contents

Contents

Page

Annex

33

Inquiry form

34

Configuration instructions

35
Foldout page

R-HG11-180.eps

Configuration aid

Switchgear Factory in Berlin, Germany

Siemens HG 11.42 2008

33

Siemens Vacuum Recloser 3AD

Annex
Inquiry form
Please copy, fill in and return to your
Siemens partner

Inquiry concerning

o Siemens vacuum

Technical data
Rated voltage

recloser 3AD

Rated lightning impulse


withstand voltage

Please

o Submit an offer
o Call us
o Visit us
Your address

Rated short-duration
power-frequency
withstand voltage
Rated short-circuit
breaking current
Rated normal current

Other values

o 12 kV
o 27 kV

o 15.5 kV
o 38 kV

o 75 kV
o 150 kV

o 110 kV
o 170 kV

o 42 kV
o 60 kV

o 50 kV
o 70 kV

o _ _ _ kV

o 12.5 kA

o 16 kA

o _ _ _ kA

o 400 A

o 630 A

o _ _ _ kV
o 125 kV

o _ _ _ kV

o 800 A

o ___A

Secondary equipment
For possible combinations see pages 20 to 23

Company

Recloser configuration

o Recloser for
o

Dept.
Name

Current and voltage sensing

pole mounting
Without control
cubicle

o Integrated current

o Made of
o

o Integrated voltage

transformers
Street

Controller equipment

Postal code/city
Phone
Fax

4 binary inputs
34 binary inputs
9 binary outputs
___

transformers

14 binary inputs

24 binary inputs

17 binary outputs

25 binary outputs

_ _ _ V AC, _ _ _ Hz

Control and sensor cable

o Without

o 6m

o ___m

o USB
o Optical

o RS485
o IRIG-B

o RS232

o Synchronizing and

o Fault locating

Function packages additional


to standard functions

Siemens AG

_ _ _ V DC

synchro-check
Loop automation

o Single-triple

Dept.

Application and other requirements


Name
Street
Postal code/city
Fax

o Please check off


Siemens HG 11.42 2008

o External voltage

sensors

Communication interfaces

34

substation

Auxiliary voltage

E-mail

o
o
o
o

o Application in

stainless steel
Others

_ _ _ Please fill in

For configuration of your


Siemens vacuum recloser 3AD

12 kV to 38 kV
75 kV to 170 kV
42 kV to 70 kV
12.5 kA and 16 kA
400 A to 800 A

3 A D

13 14 15 16

These ratings define the positions 4 to 7 of the order number.

3 A D

2nd step: Definition of the secondary equipment (see pages 20 to 23)

3 A D

Please specify the following equipment features:

Possible options:

Recloser configuration
(position 8)
Sensors
(position 9)
Controller
(position 10)
Auxiliary voltage
(position 11)
Cable length of control and sensor cable
(position 12)
Communication protocol
(position 13)
Communication interfaces
(position 14)
Functions of the controller
(position 15)
Language of operating instructions and nameplate
(position 16)

Recloser incl. control cubicle and cables, recloser without control cubicle
and cables, recloser for transformer substation, retrofit recloser
Integrated current transformers, integrated voltage transformers,
external voltage transformers
Housing size, number of function keys and three-color LEDs,
number of available binary inputs and outputs
Voltages from 48 V DC to 240 V AC

3 A D

Standard length 6 m, special lengths possible

IEC 60870-5-103 and Modbus RTU, DNP 3.0


3 A D

USB, RS485, RS232, IRIG-B, optical, ST plug


Standard protection and monitoring functions,
synchronizing and synchro-check, fault location
English, American English, Spanish and Portuguese

3 A D

These equipment features define the positions 8 to 16 of the order number.


+

3rd step: Do you have any further requirements concerning the equipment? (Please refer to page 24)
3 A D

Should you still need more options than the possible special equipment like country-specific mains sockets,
weather resistance down to 40 C, stainless-steel design, etc. please contact your responsible sales partner.

3 A D

35

3 A D

Siemens HG 11.42 2008

See page 24

See page 23

n n n n

See page 23

Ur:
Up:
Ud:
Isc:
Ir:

See page 22

Rated voltage (Ur)


Rated lightning impulse withstand voltage (Up)
Rated short-duration power-frequency withstand voltage (Ud)
Rated short-circuit breaking current (Isc)
Rated normal current (Ir)

9 10 11 12

See page 22

Possible options:

See page 22

n n n n n

See page 17

Please specify the following ratings:

See page 21

1st step: Definition of the primary part (see pages 17 to 19)

See page 21

See page 20

See page 20

Instruction for configuration of the Siemens vacuum recloser 3AD

n n n n n n n

See page 19

Please follow the steps for configuration and enter the order number in the configuration aid.
Alternatively you can also use your prompted online configurator under www.siemens.com/energy

to

You prefer to configure your Siemens vacuum recloser 3AD on your own?

If not stated otherwise on the individual pages of this catalog,


we reserve the right to include modifications, especially regarding
the stated values, dimensions and weights.
Drawings are not binding. All product designations used are
trademarks or product names of Siemens AG or other suppliers.
If not stated otherwise, all dimensions in this catalog are given
in mm.

Siemens AG
Energy Sector
Medium Voltage Division
Nonnendammallee 104
13623 Berlin
Germany
www.siemens.com/energy

General editing:
Siemens AG, Dept. PTD CC M
Erlangen

Subject to change without notice


Order No. E50001-K1511-A421-A1-7600
Printed in Germany
Dispo 31601
KG 03.08 1.0 36 En
103063 6101/6519

The information in this document contains general descriptions of the technical options available, which do not always have to be present in individual cases.
The required features should therefore be specified in each individual case at the time of closing the contract.

R-HG11-182.tif

Responsible for
Technical contents:
Siemens AG, Dept. PTD M C PPM
Berlin

For questions concerning Power


Transmission and Distribution:
You can contact our Customer Support
Center 24 hours a day, 365 days a year.