Sei sulla pagina 1di 9

####Print alarms on all TGs in BSC, and their names#########

RXASP:MOTY=RXOTG;

<rxasp:moty=rxotg;
RADIO X-CEIVER ADMINISTRATION
MANAGED OBJECT ALARM SITUATIONS

MO

SCGR SC

RXOCF-4

RSITE

ALARM SITUATION

MBURABUTURO

RXOTRX-7-10

KABUGA

OPERATOR CONDITION
RF PERFORMANCE

########check status of all TGs#############


<rxmsp:moty=rxotg;
RADIO X-CEIVER ADMINISTRATION
MANAGED OBJECT STATUS

MO

STATE BLSTATE BLO BLA LMO BTS CONF

RXOTG-1

OPER

0000 0000

STA

RXOTG-4

OPER

0000 0000

STA

########Check TG status and its children##########

<rxmsp:mo=RXOTG-511,subord;
NOT ACCEPTED
COMMAND UNKNOWN

<rxmsp:mo=RXOTG-511,subord;
RADIO X-CEIVER ADMINISTRATION
MANAGED OBJECT STATUS

MO

STATE BLSTATE BLO BLA LMO BTS CONF

RXOTG-511

OPER

0000 0000

STA

RXOCF-511

OPER

0000 0000

STA

<
############Print which TG a cell belongs to########

rxtcp:moty=rxotg,cell=k005b;

<rxtcp:moty=rxotg,cell=k005b;
RADIO X-CEIVER ADMINISTRATION
TG TO CHANNEL GROUP CONNECTION DATA

MO

CELL

RXOTG-404

CHGR

K005B

K005B

K005B

END

####Check for cell resources:

rlcrp:cell=k005a;
rlcrp:cell=k005a,detail;
##Check MO Fault Information:

RXMFP:MOTY=RXOTG,FAULTY;
RXMFP:MOTY=RXOTF,FAULTY;
RXMFP:MOTY=RXOTRX,FAULTY;
RXMFP:MO=RXOTG-133,FAULTY,SUBORD;

### Check dip, and their sites:


DTSTP: DIP=ALL, STATE=ABL;
DTSTP: DIP=210RB2;
DTdiP: DIP=210RB2;
ntcop:snt=ETM2-7;
stdep:dev=RBLT2-6720&&-6751;
rxapp:moty=rxotg;
rxasp:mo=RXOTG-115;
<rrscp:scgr=483; //// for super channels TG where TMODE is SCM
RADIO TRANSMISSION SUPER CHANNEL DATA

SCGR SC DEV

DEV1

483 0 RTPGD-1248

NUMDEV DCP STATE

RBLT2-1249

31

1 WO

END

<rxmop:mo=rxotg-483;
RADIO X-CEIVER ADMINISTRATION
MANAGED OBJECT DATA

MO
RXOTG-483

RSITE
RUHANGOII_1800

COMB FHOP MODEL


HYB SY G12

SWVERREPL

SWVERDLD

B0709R041G

SWVERACT

TMODE

B0709R041G SCM

CONFMD CONFACT TRACO ABISALLOC CLUSTERID SCGR


NODEL 4

POOL FIXED

483

DAMRCR CLTGINST CCCHCMD

PTA JBSDL PAL JBPTA


7 20 0

TGFID

20

SIGDEL

BSSWANTED PACKALG

H'0000-000C NORMAL

1010

END

## The BSC has got following main parts: CP, RP, GS and AP: Check status of these main parts:

dpwsp; should be WOrking

<dpwsp;
CP STATE

MAU SB SBSTATE
NRM B WO

#### RP Status:

RPH-A
-

RPH-B
1

BUA STATE

<exrpp:rp=all;
RP DATA

RP STATE TYPE

TWIN STATE DS

807 WO

GARP2E

IDLE

808 WO

GARP2E

IDLE

809 WO

GARP2E

IDLE

810 WO

GARP2E

IDLE

811 WO

RPI1E

IDLE

812 WO

RPI1E

IDLE

813 WO

RPI1E

IDLE

MAINT.STATE

### Print RP adress and slot number:dbtsp:tab=rpsrpbspos; busconn means is ir connect to CP bus?

<dbtsp:tab=rpsrpbspos;
DATABASE TABLE

BLOCK TAB

TABLE

RPADM RPSRPBSPOS

RPADDR

WRAPPED
NO

BRNO MAGNO SLOTNO BUSCONN

1022 31

0 YES

1021 31

25 YES

1020 31

0 YES

1019 31

25 YES

1018 31

11 NO

1017 31

1 NO

### RP HW Information: exhwp:rp=1021,slot=25;

<exhwp:rp=1021,slot=25;

WO

RMBSC1_G10B_IPA-17

AD-168 TIME 130722 1341 PAGE 1

HARDWARE INFORMATION DATA

RPBUSBRANCH MAGNO PRODUCTNAME SLOTNO RESULT


31

SCB-RP

PRODUCTNO
ROJ 208 323/4

25

EXECUTED

SERIALNO

REV

TD38445329

R2A

HARDWARE SPECIFIC INFORMATION

INFO1
20100218

##RP EVENT Logs:

DIRRP:RP=ALL;
<DIRRP:RP=ALL;
RP EVENT RECORD

COMMON EVENTS

EVENT DATE TIME REASON

ETYPE INF1 INF2

362 130722 153410 ALCEASING H'000 H'0000 H'0000


362 130722 153404 ALINITIAT H'000 H'0000 H'0000

RP AND EM EVENTS

RP TYPE
817 RPI1E

INTERFACE
RP-2

EVENT DATE TIME EM REASON ETYPE INF1 INF2 INF3 INF4


361 130722 153404 ALCEASING H'000 H'0000 H'0000 H'0000 H'0000
360 130720 174332 ALINITIAT H'000 H'0000 H'0000 H'0000 H'0000
360 130720 174332 ERWORKING H'055 H'0380 H'0001 H'0000 H'0000

RP TYPE

INTERFACE

934 GARP2E RP-2

###RP Event log per specific RP:

<DIRRP:RP=1019;
RP EVENT RECORD

RP AND EM EVENTS

RP TYPE

INTERFACE

1019 RPSCB1E RP-2

NO RP EVENT RECORDED
END

### CP Logs

DIRCP;

CP EVENT RECORD

NO DATE TIME ETYPE ACT REP BNR CODE INF1 INF2 DINO
508 130722 0100

H'018C 106 H'0001 H'0000

507 130721 0100

H'018C 106 H'0001 H'0000

506 130720 0100

H'018C 106 H'0001 H'0000

505 130719 0940

H'0006 0 H'0000 H'0000

505 130719 0940

H'0189 513 H'0000 H'0018

505 130719 0939

H'0189 512 H'0002 H'0000

505 130719 0939

1 1 YES H'0182 308 H'0001 H'0000

## Check wich STM is clock reference:


<nsstp;
CLOCK-REFERENCE STATE

REF

STATE BLS

0ETM2,MS-0

EX

2ETM2,MS-0

SB

END

### Files in AP:

aploc;

afpls

Potrebbero piacerti anche