Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
DS1235 E 01.2014
Jet nozzle
DWN2
Twist nozzle
DWV2...DR
5
30
30
4
1a
In many cases, the jet pattern can be well predicted with the help
1b
2
3
4
16
Sw
ran ivel
ge
DN
DN
The supply air jet pattern depends on the nozzle size, the dis-
21
3
Jet nozzle
mounted in the
parapet of a gallery
Jet nozzles
mounted in two
opposite walls
considerably reduced by mounting a twist element on the air intake side. The twist element is not visible from the room.
For architectural reasons, jet nozzles with and without twist
element are often placed adjacent to each other in order to get
unity of appearance.
A reduction of the jet penetration depth by using the twist
Jet nozzle
combined with
twist nozzle,
mounted in a wall
Fig. 2: Examples of arrangement
nozzles.
Where high specific supply air volume flow rates per metre are
Fig.1, middle, shows the swivel jet nozzle DW-V2. Its main com-
Size
Jet nozzle
Twist nozzle
V min
V max
V min
V max
l/s
m3/h
l/s
m3/h
l/s
m3/h
l/s
m3/h
DN 60
11
40
33
120
DN 80
21
75
61
220
10
35
40
145
DN 120
46
165
136
490
11
80
90
325
collar5.
DN 150
71
255
211
760
36
130
142
510
DN 200
125
450
378
1 360
63
225
250
900
DN 250
197
710
589
2 120
99
355
392
1 420
p. 2
DS 1235 E
01.2014
www.krantz.de
Jet nozzle
Twist nozzle
the nozzles, the layout of jet nozzles allows for the following tem-
indoor air:
8 K when cooling,
8 K when cooling,
+6 K when heating.
+6 K when heating.
10
10
0.25
0.35
0.5
0.6
0.9
1.1
H in m
Max. mounting height
H in m
Min. nozzle centre
distance 1) tmin in m
12
11
60
The graphs on pages 11 and 12 show the induction ratio, the jet
ture in relation to the jet path.
3.5
3.9
4.2
10
10
0.65
1.1
1.25
1.6
2.0
DN
20
DN
25
9
8
7
6
Jet nozzle
4
2
10
20
30
DN
80
DN
12
0
DN
15
0
DS 1235 E
3.2
www.krantz.de
2.8
10
p. 3
01.2014
4.2
15
3.9
DN 250
distance 1) tmin in m
3.5
DN 200
DN
3.2
DN 150
12
H in m
2.8
DN 120
DN
2.5
DN 80
80
H in m
Size
DN
DN
Size
DN
20
DN
40
Throw W in m
50
25
6
5
4
Twist nozzle
3
2
10
15
20
Throw W in m
25
Fig. 5: Throws of jet nozzle and twist nozzle correlated with the
1)
discharge velocity
thermal comfort
Jet nozzle
Adjustment to thermal load
For electrical adjustment, the jet nozzles must be equipped with
actuators. The discharge angle of the supply air will be set on
the basis of the measured supply and indoor air temperatures,
using the building management systems and an appropriate
control graph.
Thermostatic control (available for nozzle sizes DN 120) obviates
the need for a central control system and nozzle wiring. Each jet
nozzle is fitted with a thermostatic control unit which gets energy
Fig 8:
Left:
DW-N2
Another advantage of this control unit is that the supply air temperature is measured inside the nozzle, not at a central point such
as behind the HVAC system. With extended ductwork, significant
Fig. 9: DW-V2
Left:
Connection types
Left:
Fig. 7:
connection to pressurized
plenum or rectangular duct
www.krantz.de
DS 1235 E
p. 4
01.2014
Jet nozzle
Instructions for mounting and adjusting the nozzles 1)
In the basic setting of the swivel range, the air discharge angle of
the jet nozzle is 15 to the horizontal (with the jet nozzle being
mounted on a vertical surface) in heating mode at supply air tem-
connection type K
The swivel range can also be easily altered manually, even once
After removing the collar5, insert the jet nozzle into the duct wall
In heating mode, the supply air jet should be discharged rather flat
it is possible to alter the position of the swivel axis and thus to ad-
Mounting height
in m
Heating mode
20 C
28 C
<4
+25
46
+15
15
>6
+10
20
Cooling mode
connection type F
For connection type F, both the swivel and the non-adjustable
jet nozzles have a slip-on end 10 matching shaped parts to
15
01.2014
duct is slipped onto the connector and the jet nozzle is set to
www.krantz.de
DS 1235 E
p. 5
secured by screws.
ling
Cooling
atin
ary lubricant can be used to help turn the nozzle, in particular with
He
end of the nozzle. If the relevant end is fitted with a seal, a custom-
10
Coo
EN1506.
Heating
5
10
15
18
20
22
24
26
28
Supply air temperature in C
30
Fig 11: Inclination of jet nozzle correlated with supply air tem-
5 (up to 20 in total)
Jet nozzle
Dimensions of DW-N2
DN
D3-N
D5-N
Connection to a
pressurized plenum
DWN2DN__K
1a
1b
H
15
13
DN
D4-N
1 Nozzle
1b Flange
2 Hemisphere
1a
3 Fastening flange
3a Slot segment 2)
3b Brush seal
H1
3c Flange seal
4 Swivel axis
5 Collar
6 Adjusting screw 2)
7 Scale of degrees 2)
8 Fastening point 2)
10
15
9 Push-in end
14
10 Slip-on end
11 Electric actuator
12 Thermostatic control unit
DN
01.2014
14 Shaped part
15 Locking screw
1a
p. 6
16 Twist element
H1
1)
DS 1235 E
Size
D3-N1)
mm
D4-N
mm
D5-N
mm
D6-N
mm
H
mm
DN 60
118
139
148
140
80
DN 80
152
179
182
180
94
DN 120
238
249
268
250
132
DN 150
300
314
330
315
158
DN 200
410
399
440
400
207
DN 250
500
499
530
500
246
2)
H1
mm
50
70
90
Weight in kg
Connection
type K
Connection type
R or F
0.1
0.3
0.13
0.4
0.4
0.9
0.6
1.4
1.0
2.0
1.4
2.6
Only for connection to a pressurized plenum (for swivel jet nozzle and twist nozzle)
www.krantz.de
D6-N
13 Connection duct
Jet nozzle
Dimensions of DW-V2 and DW-V2-...-DR
H4
H2 max
H4
LM
A1 min
Sw
ran ivel
ge
30
H4
H2 max
Connection to a flexible duct
DWV2DN__B
LT
4)
H3max
A2 min
3a
isp
he
re
He
D5-V
DN
45
30
30
11
Section B - B
30
Sw
ran ivel
ge
01.2014
5
D2
3b
3c
30
D3-V
D7
Sw
ran ivel
ge
30
12
H4
H5
D5-V
4
DN
DN
D5-V
He
m
isp
he
re
30
D6-V (inside)
30
Connection to a
pressurized plenum
DWV2DN__K
(with thermostatic
control unit)
He
m
isp
he
re
15
10
H3max
D3-V
14
Sw
ran ivel
ge
Sw
ran ivel
ge
H5
D5-V
DN
4
11
30
30
DN
D5-V
30
30
D4-V
D3-V
13
Connection to a
pressurized plenum
DWV2DN__K
(with electric actuator)
Connection to a
circular duct
DWV2DN__R
He
m
i sp
he
re
15
He
m
i sp
he
re
DS 1235 E
p. 7
17
H4
H2 max
View A:
Collar 5 removed
H3 max
www.krantz.de
1)
Size
D2
mm
D3-V
mm
DN 60
168
DN 80
207
DN 120
1)
D4-V
mm
D5-V
mm
D6-V
mm
H2 max
mm
H3 max
mm
H4
mm
155
179
186
180
79
44
12
188
223
230
224
94
55
14
295
274
314
321
315
135
78
15
DN 150
376
350
399
406
400
165
96
15
DN 200
476
453
499
506
500
206
130
22
DN 250
571
543
599
606
600
261
150
22
2)
H5
mm
50
70
90
3)
3)
DW-V2
DW-V2-...-DR
2)
D7
mm
A1 min
mm
A2 min
mm
LM
mm
LT
mm
W
kg
D7
mm
315
238
1.0
99
321
244
1.3
139
124
335
390
258
367
2.6
223
199
346
405
269
381
3.9
279
249
364
420
287
396
5.4
354
314
389
450
312
424
7.0
449
399
4)
Jet nozzle
Layout sheet for DW-N2
Sound power level of DW-N2
15
0
DN
DN
DN
12
80
11
DN
12
DN
6
Note:
The diagram values for sound power level
apply to connection type K (pressurized plenum). With connection to a straight circular
duct (type R or F), the sound power level
is 1 dB(A) higher, and even 3 dB(A) higher
when connected to an elbow.
The pressure drop values apply to connection types K, R and F as well as behind an
elbow.
20
DN
25
10
9
8
7
6
5
4
10
V A
m3/h
500
400
20
30
V A
l/s
140
140
100
100
DN
100
50
V A
l/s
300
200
40
Throw W in m
40
DN
velocity
m/s
8
10
12
6
12
12
18
12
8
10
12
3
10
17
11
18
25
14
14
10
8
10
12
8
16
22
14
22
28
14
20
13
19
11
17
8
10
12
12
19
26
20
27
34
16
23
15
22
15
22
15
8
10
12
16
24
30
27
35
41
17
25
31
12
20
26
10
18
24
15
8
10
12
20
27
34
27
34
41
19
26
33
18
25
32
15
22
29
13
19
DN 120
DN 120
DN 80
50
20
flow rate
l/s
m3/h
DN 60
22
80
28
100
33
120
DN 80
40
145
50
180
61
220
DN 120
89
320
114
410
136
490
DN 150
142
510
178
640
211
760
DN 200
250
900
315
1 130
380
1 360
DN 250
395
1 420
490
1 770
590
2 120
40
DN
Discharge
12
50
30
Nozzle volume
DN 80
DN 60
DN 60
30
80
20
60
50
2 000
10
20
Throw W in m
25
4
V A
l/s
V A
l/s
700
600
700
600
500
500
400
1 000
10
400
DN
300
0
25
10
20
30 40 50
100 120
Total pressure drop pt in Pa
DN 250
DN 250
DN 200
DN 200
300
00
200
10
20
30
Sound power level LWA
in dB(A) ref. 10-12 W
01.2014
2 500
DN 150
200
2
DN
DN 150
500
400
300
DN
100
DN 150
V min = 70 l/s
100
80
80
8
15
10
20
30
40
Throw W in m
50
10
20
30 35
Sound power level LWA
in dB(A) ref. 10-12 W
20
30 40 50
100 120
Total pressure drop pt in Pa
p. 8
V A
m3/h
DS 1235 E
10
www.krantz.de
40
a = 30 +2 dB(A)
With connection type R or F to a straight circular duct with L 3 DN, the sound power level is 1 dB(A) higher, and even 3dB(A)
higher when connected to an elbow.
The pressure drop values apply to connection types K, R and F, and a nozzle angle of inclination a = 0 to 30. With an elbow
DN
15
0
00
2
DN
DN
12
80
11
DN
DN
6
12
50
2
DN
10
9
2 Requisite throw
W = 20 m
3 Angle of inclination
From diagram:
7
6
5 Size
= DN 150 selected
Dpt 60 Pa
10
V A
m3/h
500
400
20
30
100
50
V A
l/s
140
140
100
100
9 Number
= 93 units [from 1 : 6]
10 Discharge velocity
= 8.5 m/s
12
50
40
40
30
0
N8
30
60
20
DN
DN 60
2 500
2 000
01.2014
DS 1235 E
p. 9
V A
m3/h
10
20
Throw W in m
25
V A
l/s
10
V A
l/s
700
600
700
600
500
500
20
30 32
Sound power level LWA
in dB(A) ref. 10-12 W
50
N2
300
200
DN
300
10
DN 150
DN 150
DN 150
V min = 70 l/s
DN 200
200
Nozzle model
with and without
actuator
Also see above note
80
DN 250
300
0
20
5
N1
100
20
30 40 50
100 120
Total pressure drop pt in Pa
Nozzle model
without actuator
with actuator
Also see above note
DN 200
500
400
10
DN 250
400
400
1 000
10
DN 60
Nozzle model
without actuator
with actuator
Also see above note
50
10
DN 120
DN 80
DN 80
50
20
40
Nozzle model
without actuator
with actuator
Also see above note
DN 120
DN
200
40
Throw W in m
V A
l/s
300
www.krantz.de
= 20
20
30
40
Throw W in m
100
50
80
15
20
30
Sound power level LWA
in dB(A) ref. 10-12 W
40
20
30 40 50
100 120
Total pressure drop pt in Pa
l/s
m3/h
Discharge
velocity
LWA
m/s
dB(A)
DN 60
250
500
1K
2K
LWA
4K
dB(A)
250
500
1K
2K
4K
With actuator 1)
Without actuator
22
28
33
80
100
120
8
10
12
10
16
21
12
20
24
16
21
14
19
11
16
10
13
19
24
17
23
28
13
19
24
11
17
22
14
19
12
12
20
22
28
33
80
100
120
8
10
12
11
17
22
15
21
26
11
17
22
15
20
12
17
10
10
14
20
25
18
24
29
14
20
25
12
18
23
15
20
13
13
30
22
28
33
80
100
120
8
10
12
12
18
23
16
22
27
12
18
23
10
16
21
13
18
11
11
15
21
26
19
25
30
15
21
26
13
19
24
10
16
21
14
14
DN 80
With actuator 1)
Without actuator
40
50
61
145
180
220
8
10
12
13
19
23
13
23
28
13
21
25
10
18
23
10
17
10
15
21
25
19
25
29
17
23
27
15
21
25
13
17
10
10
20
40
50
61
145
180
220
8
10
12
14
20
24
18
24
28
16
22
26
14
20
24
12
16
16
22
26
20
26
30
18
24
28
16
22
26
14
18
11
11
30
40
50
61
145
180
220
8
10
12
15
21
25
19
25
29
17
23
27
15
21
25
13
17
10
10
17
23
27
21
27
31
19
25
29
17
23
27
15
19
12
12
89
114
136
320
410
490
8
10
12
16
22
27
27
33
36
19
25
30
10
17
23
13
19
14
10
17
23
28
27
33
38
20
26
31
12
18
23
14
19
13
12
20
89
114
136
320
410
490
8
10
12
17
23
28
27
33
38
20
26
31
12
18
23
14
19
13
12
18
24
29
28
34
39
21
27
32
13
19
24
15
20
14
13
30
89
114
136
320
410
490
8
10
12
18
24
29
28
34
39
21
27
32
13
19
24
15
20
14
13
19
25
30
29
35
40
22
28
33
14
20
25
10
16
21
10
15
14
142
178
211
510
640
760
8
10
12
18
24
29
30
34
38
19
26
31
14
22
27
15
22
14
10
20
142
178
211
510
640
760
8
10
12
19
25
30
29
35
40
21
27
32
16
22
27
10
16
21
14
14
30
142
178
211
510
640
760
8
10
12
20
26
31
30
36
41
22
28
33
17
23
28
11
17
22
10
15
10
15
DN 120
With actuator 1)
Without actuator
1)
250
315
380
900
1 130
1 360
8
10
12
21
27
31
29
35
30
18
24
30
21
27
32
17
24
14
10
20
250
315
380
900
1 130
1 360
8
10
12
22
28
32
30
36
40
19
25
29
22
28
32
13
19
23
12
11
30
250
315
380
900
1 130
1 360
8
10
12
23
29
32
31
37
40
20
26
29
23
29
32
14
20
23
12
11
DN 250
395
490
590
1 420
1 770
2 120
8
10
12
23
29
33
32
37
40
20
27
32
23
29
34
11
19
26
16
12
20
395
490
590
1 420
1 770
2 120
8
10
12
24
30
34
32
38
42
22
28
32
24
30
34
15
21
25
10
14
10
14
30
395
490
590
1 420
1 770
2 120
8
10
12
25
31
35
33
39
43
23
29
33
25
31
35
16
22
26
11
15
11
15
01.2014
DN 200
with an elbow.
Increase in sound power level DL in relation to air velocity
uL when mounted in a rectangular duct
1)
uL in m/s
2.0
2.5
3.0
4.0
5.0
6.0
DL in dB
12
p. 10
DN 150
10
DS 1235 E
Nozzle volume
flow rate
www.krantz.de
Angle of
inclination
Jet nozzle
Induction ratio Jet volume flow rate/Supply air volume flow rate V / V A
100
50
40
60
0
DN N 8
0
D
12 50
DN N 1 0
D
20 50
DN N 2
D
30
20
10
Induction ratio
Example: Size DN 150
5
4
Jet path L = 25 m
From graph:
Induction ratio Jet/Supply air volume flow rate V / VA = 50,
i.e. mixing of 49-fold indoor air volume flow rate after 25 m jet path
Tem
pe
rat
ure
10
4 5
20
30 40 50
Jet path L in m
Jet pa
Jet deflection
dif
fer
en
ce
th L =
2m
3
su
pp
ly
air
to
ind
5
6
7
8
9 10
oo
ra
ir
Z
15
2 LRL =
8 1 0
30
0
K
4
6
15
20
25
30
40
50
DS 1235 E
www.krantz.de
20
40 50
20
10
30
40 50
l/s
0.5
100
30 40 50
200
100
5
10 12
Jet deflection y in m
m3/h
l/s
DN 80
p. 11
01.2014
10
DN 60
+y Heating mode
40 50
100
20
30 40 50
10
200
100
200
m3/h
l/s
DN 120
50
100
30 40 50
200
300
y Cooling mode
m3/h
l/s
DN 150
100
50
1 000
200 300 400 500
100
200 300 400 500
m3/h
l/s
DN 200
300 400 500
200
100
1 000
2 000
m3/h
300 400 500
1 000 l/s
DN 250
2 000 3 000
Nozzle volume flow rate V
400 500
1 000
m3/h
Example:
Nozzle volume flow rate
Size DN 150
VA
= 140 l/s
From graph:
Jet path
L=
Jet deflection
10 m
11
Jet nozzle
0.4
25
30 0
4
50
0.3
0.2
12
20
30
40 50
0.4
0.3
0.2
l/s
0.1
100
DN 80
60
30
100
40 50
200
100
m3/h
l/s
400
200
DN 120
100
200
50
100
200
200
m3/h
DN 200
DN 200
100
400 500
200
Example:
DN 250
1 000
2 000
m3/h
300 400 500
900 l/s
DN 250
500
DN 120
DN 150
l/s
2 000
1 000
Nozzle volume flow rate V A
3 000 m3/h
DN 80
m3/h
l/s
DN 150
200
DN 60
10
4 5
1.4
1
0.8 1
0.6
3
2
20
5
4
2
1
30
10
4
20
30
10
5
20
10
4 5
3
30
20
10
5
30
20
10
20
Size DN 150
Temperature difference
supply air to indoor air
DJZL-RL = 8 K
Jet path
= 20 m
Size DN 150
From graph:
Jet path
L = 20 m
From graph:
12
u0 = 7.85 m/s
1)
to jet velocity
jet paths
Jet velocity in the jet axis at the respective points of observation on the
30
01.2014
m3/h
l/s
200
100
30 40 50
p. 12
50
20
DS 1235 E
DN 60
www.krantz.de
0.1
0.5
40
50
0.5
15
20
1.0
20
2
30 5
15
10
10
4m
Je
L=
2.0
L=
1.0
th
ath
a
tp
tp
2.0
Je
3.0
Twist nozzle
DW-V2-...-DR Layout sheet and sound power level
V A
m3/h
1 600
1 000
V A
l/s
300
200
100
30
0
12
DN
DN
20
DN
250
5
4
3
2
400
300
300
DN
200
DN
0
25
DN 0
20
DN 50
1
DN
0
12
DN
100
50
40
30
10
9
15
400
DN
DN
100
DN
50
40
80
DN
30
10
15
Throw W in m
20
250
DN
200
DN
150
DN
120
DN
80
DN
250
200
150
120
80
20
20
50
40
DN
V A
m3/h
200
500
400
80
DN
the graph on page 12. For this purpose, the jet path
10
20
Throw W in m
10
9
10
20
30
40
Sound power level LWA
in dB(A) ref. 10-12 W
Layout example:
50
10
20 30 40 50
100
Total pressure drop pt in Pa
200
From graph:
2 Maximum throw
W = 8 m
4 Size
= 6 111 l/s
= DN 200 selected
= 156 l/s
9 Discharge velocity u
= 40 units [from 1 : 5]
= 4.9 m/s
Size
DS 1235 E
www.krantz.de
Nozzle volume
flow rate
l/s
m3/h
DN 80
10
19
31
40
DN 120
22
44
64
92
DN 150
Total
Discharge
pressure
velocity
drop
m/s
Pa
35
70
110
145
2
4
6
8
5
20
50
88
80
160
240
330
2
4
6
8
36
69
106
142
130
250
380
510
DN 200
61
125
186
253
DN 250
97
197
294
395
p. 13
01.2014
250
500
1K
2K
4K
8
27
38
46
18
35
43
49
10
30
41
47
23
34
42
24
34
41
11
29
39
18
29
5
18
41
76
7
26
37
45
19
33
42
48
27
37
44
21
31
38
22
34
38
12
28
41
14
27
2
4
6
8
5
19
41
77
8
27
38
47
17
33
42
49
10
26
38
46
26
33
41
23
35
41
11
28
41
16
29
220
450
670
910
2
4
6
8
5
19
43
78
9
28
39
48
17
33
44
51
12
28
38
47
28
36
44
23
35
42
12
30
42
18
30
350
710
1 060
1 420
2
4
6
8
5
21
46
83
11
30
40
48
18
34
43
51
13
30
39
48
29
36
44
25
37
43
14
31
42
22
33
ref.10-12 W
2.0
2.5
3.0
DL in dB
uL in m/s
4.0
5.0
6.0
DL in dB
13
Accessories
Surface finish
Adjustment
duct
Insertion into circular ducts to EN 1506, with seal
Option
DW - __ DN___ __ __ ___ __
Size
General features
Function / Kind
Type code
Jet nozzle
Features at a glance
Function / Kind
N2
= non-adjustable
V2
= swivel type
Size
60 = DN 60
150 = DN 150
80 = DN 80
200 = DN 200
120 = DN 120
250 = DN 250
Option
Jet nozzles
Throws up to 50 m
Twist nozzles
Throws up to 17 m
Available in 5 sizes for volume flow rates up to 395 l/s
[1 420 m3/h]
Surface finish
0
= no coating
14
= none
DR
01.2014
p. 14
DS 1235 E
www.krantz.de
DN 250
DN 200
MA = manual
DN 150
DN 120
DN 80
DN 60
Tender text
Jet nozzle DW-N2 1)
electric actuator
.......... units
tered manually once the swivel jet nozzle is installed; this is pos-
Non-adjustable jet nozzle for air distribution into large spaces, with
ties.
fastening screws.
EN1506.
Material:
EN1506.
to RAL ....
Push-in and slip-on ends made of galvanized sheet metal
Material:
Nozzle body and collar made of aluminium in natural colour or
Make:
Type:
KRANTZ KOMPONENTEN
DW - N2 DN___ __ ___
www.krantz.de
DS 1235 E
p. 15
01.2014
Make:
Type:
KRANTZ KOMPONENTEN
DW - V2 DN___ __ __ ___ __
.......... units
Swivel jet nozzle with rounded intake featuring good aerodynamic
and acoustic properties, housed in a hemispheric casing with
opposite swivel bearings, swivel range 30, designed as
jet nozzle with large jet penetration depth for air distribution
into large spaces, discharge direction adjustable in the horizontal and vertical planes, or
twist nozzle 2) with small jet penetration depth for air distribution into narrow spaces, with built-on twist element,
fitted with:
1)
2)
15