Protective Devices
Miniature Circuit Breakers mMC.
High selectivity between MCB and back-up fuse due to low let-through
energy
Compatible with standard busbar
Twin-purpose terminal (lift/open-mouthed) above and below
Busbar positioning optionally above or below
Meets the requirements of insulation co-ordination,
distance between contacts 4 mm, for secure isolation
Suitable for applications up to 48 V DC (use mMCMDC for higher DC voltages)

Accessories:
Auxiliary switch for
subsequent installation
Tripping signal contact for
subsequent installation
Shunt trip release
Undervoltage release
Switching interlock

ASAUXSN
ASALMSN
ASSNTSN
ASUVRSC230
ASPDL

Connection diagrams
1-pole

1+N-pole

2-pole

3-pole

3+N-pole

4-pole

Technical Data
Electrical
Design according to
IEC/EN 60898-1
Current test marks as printed onto the device
Rated voltage
AC: 230/400V
DC: 48V (per pole)
Rated frequency
50/60 Hz
Rated breaking capacity according to IEC/EN 60898-1
mMCM
10 kA
mMC6
6 kA
mMC4
4.5 kA
Characteristic
B, C, D
Back-up fuse
mMCM
max. 125 A gL
mMC6
max. 100 A gL
mMC4
max. 80 A gL
Selectivity class
3
Rated peak withstand voltage Uimp
4 kV (1.2/50s)
Endurance
electrical comp.
4,000 operating cycles
mechanical comp.
20,000 operating cycles
Line voltage connection
optional (above/below)

Mechanical
Frame size
Device height
Device width
Mounting

Degree of protection
Upper and lower terminals
Terminal protection
Terminal capacity
Terminal fastening torque
Busbar thickness
Mounting

Dimensions (mm)

11

45 mm
80 mm
17.5 mm per pole (1MU)
26.3 mm: device 1P+N (1.5MU)
quick fastening with
3 lock-in positions on
DIN rail IEC/EN 60715
IP20
open mouthed/lift terminals
finger and hand touch safe,
BGV A3, VE-EN 6
1-25 mm2
2-2.4 Nm
0.8 - 2 mm
independent of position

SG_Technic_EATON_MV_E_SG_Technic_EATON_MV_E.qxd 24.11.2011 11:14 Seite 27

Protective Devices
Miniature Circuit Breakers mMCT
Independent switching contacts
With isolator function, meets the requirements of insulation co-ordination,
distance between contacts 4 mm, for secure isolation

Connection diagrams
1-pole

2-pole

3-pole

3+N-pole

4-pole

Technical Data
Electrical
Design according to
EN 60947-2
Current test marks as printed onto the device
Rated voltage
AC
230/400V
DC
60V (per pole)
Ultimate short circuit breaking capacity acc. to IEC/EN 60947-2
Characteristics B,C
In = 20-63 A 25 kA
In = 80-100 A 20 kA
In = 125 A
15 kA
Characteristic D
In = 20-63 A 25 kA
20 kA
In = 80 A
In = 100 A
15 kA
Characteristic
in accordance with
characteristics B, C, D
Back-up fuse
max. 200 A gL
Rated insulation voltage
440 V
Peak withstand voltage Uimp
4 kV
Selectivity class
in acc. with class 3
Endurance
20,000 operations

Mechanical
Frame size
Device height
Device width
Mounting

Degree of protection, built-in


Upper and lower terminals
Terminal protection
Terminal capacity

Dimensions (mm)

27

45 mm
90 mm
27 mm (1.5MU) per pole
quick fastening with
2 lock-in positions on
DIN rail IEC/EN 60715
IP40
lift terminals
finger and hand touch safe,
BGV A3, VE-EN 6
2.5-50 mm2