Sei sulla pagina 1di 23

Heating

Technical Data
Daikin Altherma low temperature split

EEDEN13-725

EHVH-C

Daikin Altherma low temperature split EHVH-C

TABLE OF CONTENTS
EHVH-C

Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Electrical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

................................................... 7

Capacity tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Domestic Hot Water performance

10

Wiring diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
17

External Connection Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

17

Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

18

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Hydraulic performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Static Pressure Drop Unit

Heating

13

External connection diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Installation Method

11

12

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Wiring Diagrams - Single Phase

11

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Piping diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Piping Diagrams

................................... 8

Dimensional drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensional Drawings

Combination table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Combination Table

3
4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Daikin Altherma low temperature split EHVH-C

1
h t l A g n nC i i - k tH i aV aHe DEH

Features
Integrated indoor unit: all-in-one floor standing unit including the
domestic hot water tank
Energy efficient heating only system based on air to water heat pump
technology

Perfect fit for new built as well as for low energy houses

Best seasonal efficiencies, providing the highest savings on running


costs

Flexible configuration with respect to heat emitters

Heating Daikin Altherma low temperature split

Daikin Altherma low temperature split EHVH-C

Specifications

2-1 Technical Specifications


Power input
Casing
Dimensions

EHVH04S18C3V

Nom.

kW

Packing
Tank

White
Precoated sheet metal

Unit

Height

mm

600
728
1,922

Height

mm

Width

mm

690

Depth

mm

818

Unit

kg

115

116

126

120

129

Packed unit

kg

128

129

139

133

142

180

260

1.4 (1)

1.9 (1)

Wood / Carton / PE wrapping foil

Weight

kg

Water volume

12
180

260
Stainless steel (EN 1.4521)

Maximum water temperature

65

Maximum water pressure

bar

10

Material

EPS
kWh/
24h

1.4 (1)

Quantity

1.9 (1)
1

Stainless steel (EH 1 4521)

Surface

1.9

Internal coil volume

8.9

Type

DC motor

Nr of speeds

Inverter controlled

Power input

Operation range

Coefficient of flow
(kV)

46

m/h

13

Domestic hot
water tank

m/h

Volume

10

Max. water pressure

bar

Pre pressure

bar

Heating

Ambien Min.
t
Max.

-25

25

Water
side

Min.
Max.

35 (13)
15 (5)

55 (5)

CDB

-25

CDB

35

-20

Water
side

Min.

25

Max.

60

Type

Brazed plate

Quantity

1
l

Water flow rate

0.9

Min.

l/min

Heating Max.

l/min

25

1.3

1.0
11

34

Insulation material

Sound power level

-25 (13)

Ambien Min.
t
Max.

Water volume

Refrigerant circuit

160

Space heating

Domestic hot water

Water side Heat


exchanger

mm
mm

Material

Expansion vessel

Depth

Material

1,732

Width

Heat loss

3-way valve

EHVH16S26C9W

0.190

Colour

Insulation

Pump

EHVH16S18C3V

0.075

Material

Heat exchanger

EHVH08S26C9W

Material

Packed unit

Weight

EHVH08S18C3V

50
EPS

Gas side diameter

mm

Liquid side diameter

mm

6.35

9.52

Nom.

dBA

42 (2)

47 (2)

28

Sound pressure level

Nom.

dBA

Water filter

Diameter perforations

mm

15.9

Material

33
1
copper - brass - stainless steel

Heating Daikin Altherma low temperature split

Daikin Altherma low temperature split EHVH-C

Specifications

2-1 Technical Specifications


Water circuit

EHVH04S18C3V

Piping connections diameter

inch

Safety valve

bar

EHVH08S18C3V

EHVH08S26C9W

Drain valve / fill valve

Yes

Shut off valve

Yes

Item

4.8 (6)

Name

Piping connections

Bar*l

Art33

Category I

Plate heat exchanger

51.0 (0.000)

Cold water in / Hot inch


water out

Art33

G 1" FEMALE

Recirculation
connection

inch

Min.

10

Max.

10

2-2 Electrical Specifications

G 1/2" FEMALE

EHVH04S18C3V

Voltage range

5.8 (6)

Thermal cutout (on indoor unit): 90-95C

Category
Ps*V

Power supply

4.4 (6)

01

Most critical part


Water circuit Domestic hot water
side

EHVH08S18C3V

Wiring connectionsQuantity
Communication cable Remark

EHVH08S26C9W

EHVH16S18C3V

EHVH16S26C9W

3
2.5 mm

Wiring connectionsElectric meter

Quantity

Wiring connectionsPreferential kWh rate


power supply

Quantity

Power: 2

Wiring connectionsDomestic hot water


pump

5.5 (6)

Yes

Total water volume


PED

4.5 (6)

Yes

Air purge valve


Safety devices

EHVH16S26C9W

Manometer

EHVH16S18C3V

G 1"1/4 (female)

Quantity

Remark

Minimum 0.75 mm (2A inrush, 1A continuous)

Wiring connectionsFor connection with


R6T

Quantity

Remark

Minimum 0.75 mm

Wiring connectionsFor connection with


A3P

Remark

Select diameter & type according to national & local regulations / Voltage: 230V / Max.current: 100mA
/ Min. 0.75mm

Wiring connectionsFor connection with


M2S

Quantity

3G

Remark

Select diameter & type according to national & local regulations / Voltage: 230V / Max.current: 100mA
/ Min. 0.75mm

Wiring connectionsFor connection with


bottom plate heater

Quantity

Remark

Select diameter and type according to national and local regulations

Wiring connectionsFor connection with


user interface
Wiring connectionsFor connection with
optional FWXV*
(demand input and
output)

Quantity

Remark

0,75 mm till 1,25 mm (max length 500m)

Quantity

Remark

100 mA, minimum 0.75 mm

Notes

For more details on current & voltage range, refer to the installation manual.

Notes
(1) Heatloss according to EN12897
(2) DB/WB 7C/6C - LWC 35C (DT=5C)
(3) The sound pressure level is measured via a microphone at a 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment.
(4) The sound pressure level mentioned is valid for pump medium speed - 0 ESP / medium speed - nominal flow / high speed - nominal flow
(5) 15C-25C: BUH only, no heat pump operation = during commisioning
(6) Including piping + PHE + back-up heater; excluding expansion vessel
(7) Value mentioned is connection after ball valves, Connection at unit is G1-1/4 FEMALE
(8) See separate drawing for operation range
(9) For *RLQ* outdoor units \>55C BUH only, no heatpump operation
(10) For *RHQ* outdoor units \>50C BUH only, no heatpump operation

Heating Daikin Altherma low temperature split

Daikin Altherma low temperature split EHVH-C

Specifications

(11) Minimum flow is mentioned for heat pump operation. To allow backup heater to operate safety a higher minimum flow is required. For *3V models 12 l/min
(12) Minimum flow is mentioned for heat pump operation. To allow backup heater to operate safety a higher minimum flow is required. For *9W models 15 l/min

(13) Refer to operation range for detail for differences between *RHQ* and *RLQ* models
(14) PED unit category: Art33: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC
(15) For more details on current & voltage range, refer to the installation manual.

1
2

Heating Daikin Altherma low temperature split

Daikin Altherma low temperature split EHVH-C

Electrical data

3-1

Electrical Data

1
3

Heating Daikin Altherma low temperature split

Daikin Altherma low temperature split EHVH-C

Combination table

4-1

Combination Table

Heating Daikin Altherma low temperature split

1
4

Daikin Altherma low temperature split EHVH-C

Capacity tables

5-1

Domestic Hot Water performance

1
5

Heating Daikin Altherma low temperature split

Daikin Altherma low temperature split EHVH-C

Capacity tables

5-1

Domestic Hot Water performance

3
1
5

Heating Daikin Altherma low temperature split

Daikin Altherma low temperature split EHVH-C

Capacity tables

5-1

Domestic Hot Water performance

1
5

10

Heating Daikin Altherma low temperature split

Daikin Altherma low temperature split EHVH-C

Dimensional drawings

6-1

Dimensional Drawings

Heating Daikin Altherma low temperature split

11

Daikin Altherma low temperature split EHVH-C

Piping diagrams

7-1

Piping Diagrams

1
7

12

Heating Daikin Altherma low temperature split

Daikin Altherma low temperature split EHVH-C

Wiring diagrams

8-1

Wiring Diagrams - Single Phase

3
1
8

Heating Daikin Altherma low temperature split

13

Daikin Altherma low temperature split EHVH-C

Wiring diagrams

8-1

Wiring Diagrams - Single Phase

1
8

14

Heating Daikin Altherma low temperature split

Daikin Altherma low temperature split EHVH-C

Wiring diagrams

8-1

Wiring Diagrams - Single Phase

3
1
8

Heating Daikin Altherma low temperature split

15

Daikin Altherma low temperature split EHVH-C

Wiring diagrams

8-1

Wiring Diagrams - Single Phase

16

Heating Daikin Altherma low temperature split

Daikin Altherma low temperature split EHVH-C

External connection diagrams

9-1

External Connection Diagrams

3
1
9

Heating Daikin Altherma low temperature split

17

Daikin Altherma low temperature split EHVH-C

10

Installation

10 - 1 Installation Method

1
10

18

Heating Daikin Altherma low temperature split

Daikin Altherma low temperature split EHVH-C

11

Hydraulic performance

11 - 1 Static Pressure Drop Unit

3
1
11

Heating Daikin Altherma low temperature split

19

Daikin Altherma low temperature split EHVH-C

11

Hydraulic performance

11 - 1 Static Pressure Drop Unit

1
11

20

Heating Daikin Altherma low temperature split

The present leaflet is drawn up by way of information only and does not
constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V.
has compiled the content of this leaflet to the best of its knowledge. No
express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products
and services presented therein. Specifications are subject to change
without prior notice. Daikin Europe N.V. explicitly rejects any liability for
any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this leaflet. All content is copyrighted by Daikin Europe N.V.

BARCODE

Daikin products are distributed by:

Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende

EEDEN13-725 04/13 Copyright Daikin


The present publication supersedes EEDEN12-725

These products are not within the scope of


the Eurovent certification program

Potrebbero piacerti anche