CHECKLIST NUMBER
INSPECTION CHECKLIST
Online Corrosion Monitoring System Material Receiving,
Storage, Handling and Preservation.
PROJECT TITLE
ITEM
No.
CRMSCL-0001
BI / JO NUMBER
ACCEPTANCE CRITERIA
DATE APPROVED
10-00914-0010
REFERENCE
D.
D1
01-SAMSS-23
Sec. 6.1.1
D2
01-SAMSS-23
Sec. 6.1.2
D3
01-SAMSS-23
Sec. 6.1.3
D4
01-SAMSS-23
Sec. 6.1.4
D5
01-SAMSS-23
Sec. 6.1.5
D6
01-SAMSS-23
Sec. 6.1.6
D7
The Probes shall have been proven to operate successfully for long
periods, typically many months, without bridging or the need for
cleaning when operating in sour service process conditions.
01-SAMSS-23
Sec. 6.1.7
D8
01-SAMSS-23
Sec. 6.1.8
D9
01-SAMSS-23
Sec. 6.1.9
D10
01-SAMSS-23
Sec. 6.1.10
Microcor Probes Type:- The M4000 series probe are called retrievable
probes and are designed for use in the COSASCO high pressure
D11 access fitting range. This permits probes to be removed or replaced at
process conditions up to 6000 PSI (400bar) and temperatures up to
400F (204C). With the COSASCO retriever and service valve.
Rohrback
Cosasco Vendor
Manual
Microcor Probes Type:- The M3000 series probes are called retractable
probes that can be removed or replaced under full system operating
D12 conditions, up to 1500PSI (100bar) and 425F (218c). With high
temperature versions this may be extended to 1000F (520C) at
pressure up to 1000PSI (67bar).
Rohrback
Cosasco Vendor
Manual
CR NUMBER
INSTRUMENTCONTRACTOR / SUBCONTRACTOR
PASS
FAIL
N/A
RE-INSP DATE
REV 0
CHECKLIST NUMBER
INSPECTION CHECKLIST
Online Corrosion Monitoring System Material Receiving,
Storage, Handling and Preservation.
PROJECT TITLE
ITEM
No.
ACCEPTANCE CRITERIA
Microcor Probes Type:- The M2000 series probes are fixed probes that
are used in high pressure or especially hazardous process streams.
D13
However, they cannot be removed or replaced without system
shutdown, unless installed in a bypass loop.
D14
CRMSCL-0001
BI / JO NUMBER
Corrosion Monitoring Access Fittings Materials:D15 Corrosion monitoring access fittings used in upstream operation will
employ Cosasco 2-inch high pressure fittings.
D16
D17
D18 Check compatibility of process fluid with probe material and seals.
DATE APPROVED
10-00914-0010
REFERENCE
Rohrback
Cosasco Vendor
Manual
01-SAMSS-23
Sec. 6.1.11
SAES-L-133 Sec
5.6.4
01-SAMSS-23
Sec. 6.1.16
ASTM G96
Sec. 7.1.3
ASTM G96
Sec. 7.1.6
D19
E.
E1
E2
Rohrback
Cosasco Vendor
Manual
E2
Verify the retrieval tool features outer barrel material type shall be
stainless steel .
Rohrback
Cosasco Vendor
Manual
E3
E4
E5
Sour Gas Service Model of Retriever tool material comply with the
requirements of NACE MR0175.
Rohrback
Cosasco Vendor
Manual
E6
Rohrback
Cosasco Vendor
Manual
E7
Verify the retriever tool kit isolation service valve maximum operating
pressure rating .
Rohrback
Cosasco Vendor
Manual
E8
Verify the retriever tool kit isolation service valve maximum operating
temperature rating.
Rohrback
Cosasco Vendor
Manual
E9
Verify the retriever tool kit isolation service valve isolation type.
Rohrback
Cosasco Vendor
Manual
Rohrback
Cosasco Vendor
Manual
Schedule Q
Att. lV
Sec. 4.2
Rohrback
Cosasco Vendor
Manual
Rohrback
Cosasco Vendor
Manual
CR NUMBER
INSTRUMENTCONTRACTOR / SUBCONTRACTOR
PASS
FAIL
N/A
RE-INSP DATE
REV 0
CHECKLIST NUMBER
INSPECTION CHECKLIST
Online Corrosion Monitoring System Material Receiving,
Storage, Handling and Preservation.
PROJECT TITLE
CRMSCL-0001
BI / JO NUMBER
ACCEPTANCE CRITERIA
CONTRACTOR / SUBCONTRACTOR
REFERENCE
Verify the retriever tool kit isolation service valve comply with the API
6FA and API 607 as a Fire-Safe Unit.
Rohrback
Cosasco Vendor
Manual
E11
Check the flarweld access fitting assembly plug type whether hollow
plug or solid plug. (hollow plug is suitable for electronic probe/device
and solid plug is suitable for mechanical probe/device).
Rohrback
Cosasco Vendor
Manual
E12
Mounting Raised Face Flange (RF) shall comply with the requirements
of ASME (ANSI) B16.5.
Rohrback
Cosasco Vendor
Manual
E13
Rohrback
Cosasco Vendor
Manual
E14
Rohrback
Cosasco Vendor
Manual
E16
CR NUMBER
INSTRUMENT-
10-00914-0010
E10
E15
DATE APPROVED
Rohrback
Cosasco Vendor
Manual
Rohrback
Cosasco Vendor
Manual
PASS
FAIL
N/A
RE-INSP DATE
REMARKS:
Contractor / Third-Party
Saudi Aramco
PMT Representative
Construction Representative*
Work is Complete and Ready for Inspection:
Name, Initials and Date:
T&I Witnessed
QC Record Reviewed
Work Verified
T&I Witnessed
QC Record Reviewed
Work Verified
T&I Witnessed
QC Record Reviewed
Work Verified
QC Inspector
PID Representative
Performed Inspection
QC Supervisor
Name, Organization,
Initials and Date:
Y = YES