b XC1AC

OsiSense XC Special
For material handling applications, type XC1AC

v With head for linear movement (plunger)

500770_1

500769_1

with slow break contacts


500768_1

Limit switches

2
Page 1/148

500771_1

500772_1

XC1AC115
XC1AC111

4
Page 1/148

XC1AC118

5
6
7
8
9
10

1/146

XC1AC117

XC1AC116

General characteristics

Limit switches

OsiSense XC Special
For material handling applications, type XC1AC

Environment characteristics
Conformity to standards
Product certifications
Protective treatment
Ambient air temperature

Special version
Version
For operation
For storage

Operating position
Vibration resistance
Shock resistance
Electric shock protection
Degree of protection
Mechanical durability
Cable entry

IEC/EN 60947-5-1, IEC 60337-1, VDE 0660-200, CSA C22-2 n 14


CSA 600 V (ac) HD
Standard: TC. Special: TH
- 25+ 70C
- 40+ 70C
All positions
9 gn (10500 Hz) conforming to IEC 60068-2-6
95 gn (11 ms) conforming to IEC 60068-2-27
Class I conforming to IEC 60536 and NF C 20-030
IP 65 conforming to IEC 60529 and NF C 20-010
10 million operating cycles
3 tapped entries for n 13 cable gland

Contact block characteristics

Conventional thermal current


Rated insulation voltage
Slow break contact blocks
Resistance across terminals
Minimum tripping force
Terminal referencing
Short-circuit protection
Electrical durability

AC supply
50/60 Hz a
inductive circuit

DC supply c
inductive circuit

10 A
500 V a and 600 V c conforming to IEC 60947-5-1, NF C 20-040
a and 600 V c conforming to CSA C22-2 n 14
8 mW
XC1AC1p1: 33 N, XC1AC1p6: 23 N, XC1AC1p7: 29 N
Conforming to CENELEC EN 50013
10 A cartridge fuse type gG (gl)
b Conforming to IEC 60947-5-1 Appendix C
b Utilisation categories AC-15 and DC-13
b Maximum operating rate: 3600 operating cycles/hour
b Load factor: 0.5
Slow break contact blocks
Power broken in VA
Voltage V
For 1 million operating cycles
For 3 million operating cycles

48
450
170

110
900
350

230
1900
430

48
100
35

110
100
40

230
95
33

Power broken in W
Voltage V
For 1 million operating cycles
For 3 million operating cycles

6
7
8
9
10

1/147

Limit switches

References,
characteristics

Type of head

OsiSense XC Special

For material handling applications, type XC1AC


Complete switches with slow break contacts

Plunger

1
2

Type of operator

End plunger

End ball bearing


plunger

References of complete switches


13
14

12

2.1

5.6

mm

12

14
13
21

11

2-pole NC + NC
simultaneous, slow break ZC1AZ14

12

11-12
13-14

11-12
21-22

9.3
mm

5.6 9
mm

24

14
11

21
22

12

23

3.7

Weight (kg)
Contact operation

4.9

mm

XC1AC171
13-14
23-24

4.8 8.5

24

13

2-pole NO + NO
staggered, slow break ZC1AZ17

14

4.3

6 mm

12
7.3

6.8 mm

3.5

mm

4.3

11-12
21-22

7 11.5

11-12
13-14

8 mm

4.5

mm

XC1AC155

5.5

11-12
21-22

mm

XC1AC165
3.7

4.9

mm

XC1AC175
13-14
23-24

mm

XC1AC166

11-12
21-22

4.5

0.530
closed
open

0.530

On end

By 30 cam

mm

XC1AC176
13-14
23-24

0.595

5.8

7 11.5

11-12
13-14

8 mm

4.5

5.5

11-12
21-22

mm

12

7.6 mm

11-12
21-22

12

mm

6.2

12
mm

XC1AC178
13-14
23-24

0.595

5.8

6.2

mm

5.2 11.5

11-12
13-14

6.8

12

7.6 mm

Maximum actuation speed


Cable entry
Connection

10

1/148

11-12
13-14

1.6
6.2

mm

11-12
13-14

4.4

11-12
21-22

6.8

12.5

7 11.5
mm

mm

XC1AC177
13-14
23-24

mm

11-12
21-22

12.5
mm

7 11.5

13-14
23-24

mm

XC1AC169

12

5.5

4.4

XC1AC159

XC1AC167

11-12
21-22

6.5 11.5
11-12
13-14

XC1AC149

mm

13-14
23-24

mm

XC1AC139

mm

mm

5.2 11.5

6.5 11.5
11-12
13-14

11.5

XC1AC129

XC1AC157

7.2 11.5

4.5

11.5

XC1AC147

mm

13-14
23-24

1.6

XC1AC137

7 10.5

11-12
13-14

11-12
13-14

XC1AC127

XC1AC168

12

6.2

mm

XC1AC158

7.2 11.5

4.8 8.5
6 mm

12

XC1AC156
13-14
23-24

7.3

XC1AC148

mm

5.6 9

13-14
23-24

mm

XC1AC146

9.3

12

XC1AC138

7 10.5

11-12
13-14

2.3

XC1AC128

XC1AC136

4.8 8

11-12
13-14

mm

11-12
13-14

12

7.5 mm

0.870

Complementary characteristics
Switch actuation
Type of actuation

2.3

6 7.5

11-12
13-14

11-12
21-22

11-12
13-14

XC1AC126

XC1AC145

XC1AC161

11-12
21-22

mm

XC1AC151
13-14
23-24

2-pole NC + NC
staggered, slow break ZC1AZ16

4.8 8
3.5

5.6

XC1AC135

XC1AC141

23

13

2-pole NO + NO
simultaneous, slow break ZC1AZ15

6.8 mm

XC1AC131

14

12

11

2-pole NO + NC
make before break ZC1AZ13

11-12
13-14

XC1AC125

6 7.5

22

mm

XC1AC121
11-12
13-14

Needle bearing
mounted roller
lever plunger

XC1AC115

2.1
9
XC1AC111

13

2-pole NC + NO
break before make, slow break ZC1AZ12

Offset roller lever Reinforced roller


plunger
lever plunger

XC1AC115
XC1AC118
XC1AC116
XC1AC118
XC1AC117XC1AC117XC1AC117
XC1AC119
XC1AC116

XC1AC111
11-12
13-14

11

11

Single-pole CO
slow break ZC1AZ11

Roller lever
plunger

0.5 m/s
1 m/s (direction A), 0.5 m/s (direction B) (1)
3 tapped entries for n 13 (DIN Pg 13.5) cable gland, clamping capacity 9 to 12 mm
(2 entries fitted with blanking plug)
Screw terminals. Clamping capacity: min. 1 x 0.5 mm 2, max. 1 x 2.5 mm 2
(1) For a 45 cam the maximum actuation speed becomes 0.5 m/s and for a 15 cam, 1 m/s.

11-12
21-22

12
mm

5.5

XC1AC179
13-14
23-24

0.870

12

7.5 mm

Limit switches

Dimensions

OsiSense XC Special

For material handling applications, type XC1AC


Complete switches with slow break contacts

XC1AC1p1

XC1AC1p5

XC1AC1p6

53
26

20

20

37

53

67

(1)

67

44

77

44

83

83
=

(1)

12

139

47
130

30
113

12

83

12

56

53

77

(1)
44

67

77

XC1AC1p7, XC1AC1p9

XC1AC1p8

110
53
37

3
5

30

20

44

83

12

156.5

56

73.5

28

83
(1)

53
45.5

14

139

12

67
77

(1)
44

67

77

(1) 3 tapped entries for n 13 cable gland or ISO 20 with adaptor DE9RA1620.
: 2 elongated holes 6.5 x 10.

7
8
9
10

1/149

References

Limit switches

OsiSense XC Special
For material handling applications, type XC1AC
Replacement parts

Plunger heads
Type of operator

Type of actuation

Reference

Weight
kg

For actuation on end


ZC1AC001

2
3

Maximum
actuation
speed

End plunger

0.5 m/s

ZC1AC001

0.035

ZC1AC005

0.050

ZC1AC006

0.100

ZC1AC007

0.375

ZC1AC008

0.100

ZC1AC009

3.380

For actuation by 30 cam


End ball bearing plunger 0.5 m/s

ZC1AC005

Roller lever plunger

1 m/s
(directionA)
0.5 m/s
(directionB)

Reinforced roller lever


plunger

1 m/s
(directionA)
0.5 m/s
(directionB)

Offset roller lever


plunger

1 m/s
(directionA)
0.5 m/s
(directionB)

Needle bearing mounted 1 m/s


roller lever plunger
(directionA)
0.5 m/s
(directionB)

ZC1AC006

13

ZC1AZ17

0.040

Reference

Weight
kg
3.380

13
14
21

23
21

24

22

11
11
12

12

13

0.040

14

ZC1AZ16

11

0.045

12

14

NO + NO staggered

ZC1AZ15

22

NC + NC staggered

0.045

23

ZC1AC008

ZC1AZ14

24

NO + NO simultaneous

11

0.040

13

NC + NC simultaneous

ZC1AZ13

14

NO + NC make before break

0.045

11

ZC1AC007
ZC1AC009

ZC1AZ12

12

NC + NO break before make

ZC1AZ11

Weight
kg
0.040

13

Reference

14

CO, single-pole

Scheme

12

Contact blocks
Type of contact

Adaptation plate
Description

10

ZC1AZ1p

1/150

Mounting plate
(For replacing an old version type RN-67522 limit switch
by an XC1AC limit switch)

ZC1AZ8

Limit switches

Dimensions

OsiSense XC Special
For material handling applications, type XC1AC
Replacement parts

Dimensions

ZC1AC001

ZC1AC005

ZC1 AC006

53

20
53

20

37

26
5

53
56

47

30

ZC1AC008

2
3

ZC1AC007, AC009
110

53
37

3
5

30

20

53
45.5

16

73.5

56

28

5
6
7
8
9
10

1/151

Potrebbero piacerti anche