Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
SCADA/EMS
Syarif Hidayat
SCADA/EMS Hardware
Architecture
Energy
Management
System
EMS
Server Modes
Process Control Mode
Test Mode
(System and Database, e.g. after Release
Upgrading)
Training Mode
Independent Operation Mode
(Software Development and Testing)
System Configuraton
Advantages of a Relational
Source Database
Standard query language SQL
Modification and Extension of the data base
scheme is easy
Comfortable tools exist
(Graphical user interface, Report generator, Queryby-Example)
UI Functions
UI Functions (2)
Lists and Logs
Visualization and Operation in Scrollable Windows, Screen
and/or Printer Output
Curve Display/Trending
Display in any Worldmap (separate window or integrated),
Display of Historical and Forecasted Values
Softcopy
Screen or Window Output to Different Printers
Operator Notebook
Integrated Notebook Window, Schedule Function
Remote UI I Workstations
No Distance Limitations by Usage of X.25
SCADA Functions
Alarm and Event Processing
Alarm / Event Administration
Operator Alarming
Assignment to Alarm Classes and Technological Area
Responsibility
Monitoring features
Monitoring network status changes during control
operations Plausibility checks during creation of
control sequences
Network applications security check
Check-back monitoring
Check before operate (dependent on RTU )
Feeder switching
Busbar change .
Line switching
Transformer switching
EMS-DMS Difference
EMS - Transmission DMS - Distribution
Characteristics of EMS
Clear and Up-to-Date Information Display and Secure
Network Control
Simple and Quick Data Input and Maintenance
Easy Handling of Scheduled Switching Operations
Support for Fault Location & Isolation, Service
Restoration and Network Reconfiguration
Better Utilization of Network Capacity
Power Loss Minimization
Increase of Supply Reliability and Quality
Support for Enterprise-Wide Information System
Integration
EMS Functions
Automatic Dispatching
Power System Analysis
Automatic Dispatching
Operation Monitor (OM), 10 seconds
System Frequency
Actual Generation
Actual Load
Surplus/Deficiency of power
Area Control Error (ACE)
Constant Frequency Control
Frequency and Time Error Control
Pg = Po +- N*Pr
Pg = Unit Desired Generated Power
Po = Unit base Point
Pr = Unit Regulation Bandwidth
N = Analog Signal of LFC (-1 -- +1)
Branch outages
Reactor/capacitor switching
Generator outages
Load outages
State changes of switching
Off-line/on-line modes
Utilize base cases
Interactive input/output operation
Calculate and display:
Active and reactive power flow
Magnitude and angle of bus voltages