Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
April 2011
installation guide
Front Matter
Trademarks
Brand names and product names included in this document are trademarks, registered trademarks, or trade names of their respective holders.
ii
64192RK5K5FL1-5B
Revision History
Revision History
Revision
Date
Description
March 2011
Initial release.
April 2011
Conventions
The following typographical conventions are used in this document:
This font indicates a cross-reference link.
This font indicates screen menus, fields, and parameters.
THIS FONT indicates keyboard keys (ENTER, ESC, ALT). Keys that are to be pressed simultaneously are shown with a plus (+) sign (ALT indicates that the ALT key and X key should be
pressed at the same time).
This font indicates references to other documentation and is also used for emphasis.
Thisfont indicates on-screen messages and prompts.
Thisfont indicates text to be typed exactly as shown.
THIS FONT indicates silk-screen labels or other system label items.
This font is used for strong emphasis.
64192RK5K5FL1-5B
iii
Hazard Classifications
The following hazard classifications are used in this document:
DANGER
DANGER indicates a hazard with a high level of risk which, if not avoided,
will result in death or serious injury.
WARNING
WARNING indicates a hazard with a medium level of risk which, if not
avoided, could result in death or serious injury.
CAUTION
CAUTION indicates a hazard with a low level of risk which, if not avoided,
could result in minor or moderate injury. CAUTION can also be used to alert
against unsafe practices associated with events that could lead to personal
injury.
NOTICE
Notice call-outs indicate a potentially hazardous situation not related to
personal injury, such as messages related to property damage only.
NOTE
Notes inform the user of additional, but essential, information, or features.
iv
64192RK5K5FL1-5B
Icons
Icons
The following icons are used throughout the ADTRAN document suite.
jobAid
installation guide
deployment guide
application guide
reference guide
diagnostic guide
safety and regulatory
engineering guide
release notes
upgrade guide
user guide
Training
ADTRAN offers training courses on our products. These courses include overviews on
product features and functions while covering applications of ADTRAN product lines.
ADTRAN provides a variety of training options, including customized training and courses
taught at our facilities or at customer sites.
For inquiries concerning training, contact ADTRAN:
Training Phone: 800-615-1176, next. 6303
Training Fax: 256-963-6217
Training Email: training@adtran.com
64192RK5K5FL1-5B
vi
64192RK5K5FL1-5B
Contents
Scope of this Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
In this Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Related Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Cabinet Views . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
System Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Safety and Regulatory Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Shipping Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Tools and Materials Required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chassis Installation and DC Power/Ground Wiring . . . . . . . . . . . . . . . . . . . . . . . . .
Data Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Alarm Wire Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DLC Converter Cable Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Protector Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Turn Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12
13
14
16
18
18
21
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Appendix A
Warranty and Customer Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
ADTRAN Customer Care . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
ADTRAN Sales. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
ADTRAN Technical Support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
ADTRAN Repair/CAPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
Repair and Return Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
64192RK5K5FL1-5B
vii
Figures
Figure 1.
Figure 2.
Figure 3.
Figure 4.
Figure 5.
Figure 6.
Figure 7.
Figure 8.
Figure 9.
Figure 10.
viii
64192RK5K5FL1-5B
Tables
Tables
Table 1.
Table 2.
Table 3.
Table 4.
Table 5.
Table 6.
Table 7.
Table 8.
Table 9.
64192RK5K5FL1-5B
Topic List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Related Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Total Access 1500 Expansion Kit Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Total Access 5000 Line Modules Required for Total Access 1500 Expansion . 11
Total Access 1500 DS-1 Cable Connections . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Total Access 5000 to Total Access 1500 RS485 Cable Connections . . . . . . . . 16
Total Access 1500 to Total Access 5000 Alarm Connections . . . . . . . . . . . . . . 17
288X Protector Assignments (Block #3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
480X Protector Assignments (Block #5) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
ix
64192RK5K5FL1-5B
In this Guide
This guide contains the topics listed in Table 1.
Table 1. Topic List
Topic
64192RK5K5FL1-5B
See Page
Introduction
Installation
12
Maintenance
22
Related Documentation
Refer to Table 2 for additional information regarding the Total Access 1500 Expansion Kit.
Table 2. Related Documentation
Title
Part Number
61180001L1-5
61180001L1-22
61180011L4-22
Total Access 5000 Line Module Input/Output Dual Champ 50-Pin Divided Rear Panel
Job Aid
61187401G1-22
Total Access 5000 Access Module Input/Output Blank Panel Job Aid
61187923G1-22
61187001G1-22
61187001G1-5
61187001G1-17
64192RK5K5FL1-5B
Introduction
Introduction
The Total Access 1500 Expansion Kit (P/N 4192RK5K5FL1) adds a Total Access 1500 to the
following cabinets containing a Total Access 5000 OSP System:
288-Line Cross Connect (288X) Cabinet (P/N 41925K288XL1/L2)
480-Line Cross Connect (480X) Cabinet (P/N 41925K480XL1/L2)
The addition of this expansion kit provides the capacity for up to 96 additional DS0 Special
Circuits.
Cabinet Views
See Figure 1 and Figure 2 for a front view of the 288X and 480X cabinets with the Total Access
1500 Expansion Kit installed.
64192RK5K5FL1-5B
64192RK5K5FL1-5B
Introduction
System Diagrams
See Figure 3 through Figure 6 for system diagrams of the 288X and 480X cabinets before and
after installation of the Total Access 1500 Expansion Kit.
Cross
Connect
F2
1100
F1
1100
F1
101 200
F1
201 300
F2
101 200
F2
201 300
F2
301 400
F2
401 500
Slots 14-22
Not Used
Slot 1
Slot 2
Slot 3
Slot 4
Slot 5
Slot 6
Slot 7
Slot 8
Slot 9
Slot 10
Slot 11
Slot 12
Reserved
for SCM Card
Slot 13
288 Lines
POTS+ADSL
F2
501 600
25-Pair
Splice Modules
64192RK5K5FL1-5B
RS485
Alarm
216 Lines
POTS+ADSL
LP2/RX
LP1/TX
Slot 1
Slot 2
Slot 3
Slot 4
Slot 5
Slot 6
Slot 7
Slot 8
Slot 9
LP1/TX
Slots
LP2/RX
10-12
Not Used
Cross
Connect
F2
1100
F1
1100
F1
101 200
F1
201 300
F2
101 200
F2
201 300
F2
301 400
F2
401 500
D4 To DLC Converter
Cable (P/N 1180011L4)
8 HDSL4, 4 T1
24 DS0
Slots 1-6
PA
PC
PB PD
72 DS0 Output
(Future)
F2
501 600
25-Pair
Splice Modules
64192RK5K5FL1-5B
Introduction
Slot 1
Slot 2
Slot 3
Slot 4
Slot 5
Slot 6
Slot 7
Slot 8
Slot 9
Slot 10
Slot 11
Slot 12
Reserved
for SCM Card
Slot 13
Slot 14
Slot 15
Slot 16
Slot 17
Slot 18
Slot 19
Slot 20
Slot 21
Slot 22
Not Used
480 Lines
POTS+ADSL
Cross
Connect
F2
1100
F2
101 200
F1
1100
F1
101 200
F2
201 300
F2
301 400
F1
201 300
F1
301 400
F1
401 500
F2
601 700
F2
701 800
F2
401 500
F2
501 600
F2
801 900
F2
901 1000
25-Pair
Splice Modules
64192RK5K5FL1-5B
RS485
Alarm
4 DS1 (Ports 5-8)
LP2/RX
LP1/TX
408 Lines
POTS+ADSL
1 2 3
Cross
Connect
F2
1100
F2
101 200
F1
1100
F2
201 300
F1
101 200
F2
301 400
PA
PC 72 DS0 Output
(Future)
PB PD
4 5
F1
201 300
F2
401 500
24 DS0
Slots 1-6
Slot 13
Slot 14
Slot 15
Slot 16
Slot 17
Slot 18
LP1/TX
LP2/RX
Slot 1
Slot 2
Slot 3
Slot 4
Slot 5
Slot 6
Slot 7
Slot 8
Slot 9
Slot 10
Slot 11
Slot 12
Reserved
for SCM Card
8 HDSL4, 4 T1
F1
301 400
F2
501 600
F2
601 700
F1
401 500
F2
701 800
F2
801 900
F2
901 1000
25-Pair
Splice Modules
64192RK5K5FL1-5B
Introduction
WARNING
To prevent electrical shock, do not install equipment in a wet location or
during a lightning storm.
CAUTION
CAUTION!
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY
NOTE
This product is intended for installation in Restricted Access Locations only.
This device complies with Part 15 of the FCC rules. Operation is subject to the following two
conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause
undesired operation.
Changes or modifications not expressly approved by ADTRAN could void the users
authority to operate this equipment.
64192RK5K5FL1-5B
Shipping Contents
The Total Access 1500 Expansion Kit consists of the components listed in Table 3. After
unpacking the Expansion Kit, inspect it for damage. If damage has occurred, file a claim with
the carrier then contact ADTRAN Customer Service. Refer to Appendix A, Warranty and
Customer Support for further information. If possible, keep the original shipping container
for returning the Expansion Kit for repair or for verification of shipping damage.
CAUTION
CAUTION!
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY
10
Description
Part Number
Quantity
1180001L1
1187401G1
1187923G1
1180011L4
N/A
N/A
RS485 Cable
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
64192RK5K5FL1-5B
Introduction
Part Number
Quantity
Cable Tie
N/A
N/A
64192RK5K5FL1-5
NOTE
The Expansion Kit does not include Total Access 5000 or Total Access 1500
modules, which are purchased separately. The Total Access 5000 modules
listed in Table 4 are required for the Total Access 1500 Expansion. The Total
Access 1500 modules required vary, depending on the particular application.
Table 4. Total Access 5000 Line Modules Required for Total Access 1500 Expansion
64192RK5K5FL1-5B
Description
Part Number
Quantity
1187310L1
1187300L1
11
Installation
The installation procedure consists of the following main steps:
Chassis Installation and DC Power/Ground Wiring on page 13
Data Connections on page 14
Alarm Wire Connections on page 16
DLC Converter Cable Connections on page 18
Protector Assignments on page 18
Turn Up on page 21
12
64192RK5K5FL1-5B
Installation
NOTE
Apply antioxidant compound to all ground and power interfaces before
making wire connections.
3. Connect the Total Access 1500 ground wire provided in the kit between the ground
terminal on the Total Access 1500 backplane (see Figure 7) and the rack.
4. Connect the primary and secondary DC power wires (48V and RTN) provided in the kit
between the DC power system and the Total Access 1500 power terminals as follows:
a. Connect the ring terminal ends of the four power wires to the primary and
secondary 48V and RTN terminals on the Total Access 1500 backplane according
to the wire labels (see Figure 7).
b. Connect the unterminated ends of the primary 48V and RTN wires to GMT fuse
position 2 on the DC power system.
c. Connect the unterminated ends of the secondary 48V and RTN wires to GMT fuse
position 3 on the DC power system.
NOTE
Do not install fuses for the Total Access 1500 until directed later in the
procedure.
Figure 7. Total Access 1500 (Rear View) Power and Ground Terminals
64192RK5K5FL1-5B
13
Data Connections
Make data connections between the Total Access 1500 and Total Access 5000 as appropriate
for the cabinet model as follows. Refer to the schematics in System Diagrams on page 5 as
needed.
1. At the rear of the Total Access 5000 Chassis:
a. Disconnect the Champ cables from the following slots.
288X cabinet - slots 10, 11, and 13
480X cabinet - slots 19, 20, and 21
Label the cables from slots 10 and 11 (288X) or slots 19 and 20 (480X) with their slot
numbers as they will be reused later in the procedure.
b. Remove the LMIO2 panel from the following slots:
288X cabinet - slots 13 and 14
480X cabinet - slots 19, 20, 21, and 22
c. Install the LMIO2-CH50D (P/N 1187401G1) provided in the kit over the following
slots. Refer to the Total Access 5000 Line Module Input/Output Dual Champ 50-Pin
Divided Rear Panel Job Aid (P/N 61187401G1-22) for installation instructions.
288X cabinet - slots 13 and 14
480X cabinet - slots 19 and 20
d. In the 480X cabinet only, install an AMIO2 Blank (P/N 1187923G1) over slots 21 and
22. Refer to the Total Access 5000 Access Module Input/Output Blank Panel Job Aid
(P/N 61187923G1-22) for installation instructions. The AMIO2 Blank is not used in
the 288X cabinet.
2. Connect the male Champs on the Y cables to the newly installed LMIO2-CH50D on the
Total Access 5000 backplane as follows:
a. Connect the male Champ labeled LOOP1/TX-OUT to the TX OUT LOOP 1
connector on the following slot:
288X cabinet - slot 14
480X cabinet - slot 20
Torque the captive Champ screw provided to 3.6 in lbs. Secure the lower end of the
Champ cable to the LMIO2-CH50D using one of the cable ties provided.
b. Connect the male Champ labeled LOOP2/RX-IN to the RX IN LOOP 2 connector
on the following slot:
288X cabinet - slot 13
480X cabinet - slot 19
Torque the captive Champ screw provided to 3.6 in lbs. Secure the lower end of the
Champ cable to the LMIO2-CH50D using one of the cable ties provided.
3. Locate the two cables that were disconnected from the Total Access 5000 and modify the
male Champs so they can mate with the female Champs on the Y cables:
a. Replace the screw at the top of the Champ with the 0.400-inch captive Champ screw
provided in the kit.
b. Remove the clip at the base of the Champ as shown in Figure 8.
14
64192RK5K5FL1-5B
Installation
Replace
Screw
Remove
Clip
64192RK5K5FL1-5B
Wire Color
WHT/BLU
P11 A - T
BLU/WHT
P11 A - R
WHT/ORG
P10 B - T
ORG/WHT
P10 B - R
WHT/GRN
P9 C - T
GRN/WHT
P9 C - R
WHT/BRN
P8 D - T
BRN/WHT
P8 D - R
Drain
Ground
15
Wire Color
WHT/BLU
A - T1
BLU/WHT
A - R1
WHT/ORG
B - T1
ORG/WHT
B - R1
WHT/GRN
C - T1
GRN/WHT
C - R1
WHT/BRN
D - T1
BRN/WHT
D - R1
Drain
Ground
6. Wire wrap the RS485 cable from the Total Access 5000 to the Total Access 1500 according
to the labeling, color coding, and connections shown in Table 6.
7. Ensure that the RS485 switch (SW2) on the Total Access 1500 backplane is set to EN
(enable).
Table 6. Total Access 5000 to Total Access 1500 RS485 Cable Connections
Label
TA5000 RS485
Out
Total Access
5000 Pin
Wire Color
Total Access
1500 Pin
RS485 Out-A
WHT/BLU
P12 - RS485A
RS485 Out-B
BLU/WHT
P12 - RS485B
RS485 Out-GND
Drain
NC
Label
TA1500 RS485
16
64192RK5K5FL1-5B
Installation
17
-48
ALM
SW1
OUT
1
CLK
1
TERM
21
CLK IN
21
J23
21
J24
J12
J13
J14
J15
J16
O
N
IN
21
TA1500 ALARM
64192RK5K5FL1-5B
Total Access
5000 External
Inputs Pin
Wire Color
9-A
WHT/BLU
VMJ (NO)
9-B
BLU/WHT
VMJ (C)
10 - A
WHT/ORG
VMN (NO)
10 - B
ORG/WHT
VMN (C)
Label
TA1500 ALARM
17
MANAGEMENT
Pair1
PAIR 1
T/ R
50
26
25
IN
RTN
-48VPRIMARY
ETHERNET
Pair2
PAIR 2
T1 / R1
50
1
26
Pair3
WARNING
PAIR 3
E / SG
50
1
26
IN
RTN
-48V SECONDARY
Pair4
PAIR 4
M/ SB
50
PGTC
1
25
50
PA
PB
PC
PD
Figure 10. Total Access 1500 (Rear View) with DLC Converter Cable
2. Connect the Champ labeled PA to the cable that was formerly connected to Total Access
5000 slot 13 (288X) or slot 21 (480X). Tighten the screw the top of each Champ to secure.
(The Champs labeled PB, PC, and PD are for future expansion and are not connected.)
3. Replace the existing door labels with the new labels provided in the kit.
Protector Assignments
New protector assignments for the Total Access 1500 and Total Access 5000 are shown in
Table 8 (288X) and Table 9 (480X).
NOTE
F1 cross connect assignments for the 288X and 480X cabinets match the
protector assignments.
18
64192RK5K5FL1-5B
Installation
Slot
Function
Protector
Module
Position
276
227
277
228
278
230
4
5
Loop 1
Slot
Port
1
2
279
280
281
232
282
233
283
234
284
235
236
T1 (Slot 14)
231
226
229
237
2
3
TX OUT
238-250
Not Used
285
286
287
288
289
252
290
253
291
292
255
4
5
Loop 2
293
294
257
295
258
296
259
297
260
261
262
263-275
T1 (Slot 14)
256
251
254
64192RK5K5FL1-5B
Port
2
3
4
RX IN
298
299
300
4
Not Used
Not Used
19
Slot
Function
Protector
Module
Position
476
427
477
428
478
430
4
5
Loop 1
Slot
Port
1
2
479
480
481
432
482
433
483
434
484
435
436
T1 (Slot 20)
431
426
429
437
2
3
TX OUT
438-450
Not Used
485
486
487
488
489
452
490
453
491
492
455
4
5
Loop 2
493
494
457
495
458
496
459
497
460
461
462
463-475
T1 (Slot 20)
456
451
454
20
Port
2
3
4
RX IN
498
499
500
4
Not Used
Not Used
64192RK5K5FL1-5B
Installation
Turn Up
To turn up the system, complete the following steps:
1. Install the 7.5A GMT fuses provided in the kit into fuse positions 2 and 3 on the front of
the DC power shelf.
2. Install the Total Access 1500 power supply unit (not included).
3. Verify that the Total Access 1500 powers up (the green power LED on the Total Access
1500 should light up).
4. Verify proper voltage (54 VDC) at the Total Access 1500.
64192RK5K5FL1-5B
21
Maintenance
The Total Access 1500 does not require routine maintenance for normal operation. Do not
attempt to repair the Total Access 1500 in the field. Repair services are obtained by returning
the defective unit to ADTRAN. Refer to Appendix A, Warranty and Customer Support for
further information.
22
64192RK5K5FL1-5B
Appendix A
Warranty and Customer Support
Warranty
ADTRAN will replace or repair our products within the warranty period if they do not meet
their published specifications or fail while in service. Warranty information can be found at
www.adtran.com/warranty.
ADTRAN Sales
Pricing/Availability: 1.800.827.0807
ADTRAN Repair/CAPS
Return for Repair/Upgrade: 1.256.963.8722
64192RK5K5FL1-5B
A-1
installation guide