Sei sulla pagina 1di 14

SIMtech

20 July 2010

OWNER Manual
Multi GAMINATOR block type
The author of this guidance spares large attention drafting and association of technical information, taking into account
advantages of progressive supervisory mechanisms. Nevertheless, it is impossible fully to eliminate possible errors. Therefore a
producer carries no responsibility, including legal, for any consequences which can arise up from incorrect positions of this
guidance. An author will thank for any error diagnostics.

Introduction
Multi GAMINATOR block type alternative to the original programs of
Gaminator on the platform of Cool Fire I. In this playing program the
independent choice of version of set of slots of Gaminator is possible
from I for the XXX versions, and also forming of the set is possible
from the games resulted below. This product has similar graphic arts
with the programs of Cool Fire I, but is not a copy or modification of
multigame of Novomatic.
Games of multigame Multi GAMINATOR block type:
Always Hot
Bananas Go Bahamas
Beatle Mania
Book Of Ra
Columbus
Dolphins Pearl
Hot T arget
Just Jewels
Lucky Ladys Charm
Magic Money
Marco Polo
Olivers Bar
Pharaohs Gold II
Queen Of Hearts
Riches Of India
Roller Coaster
Sharky
Sizzling Hot
The Money Game
Ultra Hot
Unicorn Magic
Venetian Carnival
The mathematical algorithm of work of the program is similar with
original Gaminator, only that goes out on the set percent for less of
games.
User's guide

written by http://www.simtech.com.ua

Multi Gaminator block type

During setting any of variants of acquisition in the corps of vehicle


will make sure in his normal aeration! In the case of absence of the
normal cooling correctness of work of device is not guaranteed.

Installation.
For the feed of pay the power module is required with 24pin ATX Power
Connector, by power more 100Vt. At the turned off feed of the power
module will connect in turn: feed-in sockets from the power module:
24pin ATX, 4pin ATKH 12v. We connect the cord of sound and interface
cord of management comptroller . On the pay of comptroller connect a
feed from the power the socket of 4pin module +5V GND GND +12V.
We connect the lower monitor of vehicle in the socket of VGA, in the
socket of DVI overhead (take into account that an overhead monitor
will work only with a digital signal, the type of cable and monitor
must be expected under DVI-D!) Connect wires of keyboard of automat to
the regional socket of JAMMA 72pin. Pin out table is resulted in a
table in addition.

User's guide

written by http://www.simtech.com.ua

Multi Gaminator block type

Game and software.


Management

How to carry out the input of credits.


1). Turn the key of operator briefly (an automat will be commuted in a managing menu)

Active buttons:
HOLD 4 - Down
HOLD 5 - Enter

2). Press the active keys for an entrance in a menu ATTENDANT

Active buttons:
HOLD 1 - Back
HOLD 4 - Down
HOLD 5 Enter

3). Choose a point REMOTE IN

Active buttons:
HOLD 1 - Back
HOLD 3 - 10 CREDITS
HOLD 4 - 100 CREDITS
HOLD 5 - 1000 CREDITS

4). Press the necessary keys for setting of the required value of credit.
5). The chosen credit will be set automatically on a credit meter.
6). Briefly turn the key of operator.
7). An automat automatically will be commuted in the playing mode.
The function of REMOTE IN can be used only, if it is included in an administrator
menu.

User's guide

written by http://www.simtech.com.ua

Multi Gaminator block type


How to carry out handpay payment.
1). Turn the key of operator briefly (an automat will be commuted in a managing menu)

Active buttons:
HOLD 4 - Down
HOLD 5 - Enter

2). Press the active keys for an entrance in a menu ATTENDANT.

Active buttons:
HOLD
HOLD
HOLD
HOLD

1
2
4
5

Back
Up
Down
Enter

3). Choose a point HANDPAY CREDIT

Active buttons:
HOLD 1 - Back

HOLD 5 - HandPay

4). Press the necessary keys for a removal and payment of the value of credit
required by hand.
5). Payment by hand automatically will be registered on the meter of payments.
6). Briefly turn the key of operator.
7). An automat automatically will be commuted in the playing mode.

User's guide

written by http://www.simtech.com.ua

Multi Gaminator block type

Managing menu
For included in the complete administrator menu of management of owner briefly turn
the key of operator, open a door FRONT DOOR SERVICE (lock the contact of 16a on
earth). After the eigentone of the unclosed door once again turn the key of operator.
Will appear AUDIT MENU with additional points MACHINE SETUP and ADMINISTRATION.

ATTENDANT> REMOTE IN

REMOTE IN: Press the necessary keys for setting of the required value of credit.
CURRENT CREDIT: Shows the size of current credit.

The proper cost and set credit of every payment transaction is shown.

ATTENDANT> HANDPAY CREDIT

HANDPAY CREDIT: Press the proper keys for the upcast of present sum.
CURRENT HANDPAY: Shows the size of current credit.
The proper cost and set credit of every payment transaction is shown.

User's guide

written by http://www.simtech.com.ua

Multi Gaminator block type


ACCOUNTING> MASTER ACCOUNTING

TOTAL IN: Lump sum of all entered bank-papers and added credits through a
function REMOTE IN.
BILL IN: Lump sum of the accepted bank-papers.
REMOTE IN: Lump sum of all added credits through a function REMOTE IN.

TOTAL OUT: Lump sum of all paid credits.


HANDPAY: Lump sum of all paid credits through a function
TOTAL IN-OUT: Difference between TOTAL IN TOTAL OUT.

HANDPAY.

The proper cost and set credit of every payment transaction is shown.

DIAGNOSTIC> PROGRAM VERSION

Program version: Current version of the program.


Internal version: Current version of assembling of graphic package.

User's guide

written by http://www.simtech.com.ua

Multi Gaminator block type


DIAGNOSTIC> BUTTON AND LAMP TEST

BUTTON TEST: Shows the real position of the button ON/OFF.


For an exit from the mode of testing retain together HOLD1 and HOLD2
DIAGNOSTIC> VIDEO TEST

VIDEO TEST: Used for verification of the colour modes of monitors.


GAME HISTORY

History of the last games is looked over in this mode.

User's guide

written by http://www.simtech.com.ua

Multi Gaminator block type


GAME STATISTIC> The Money Game

In this mode statistics are looked over on each of slots games.


MACHINE SETUP> LIMIT SETUP

CREDIT LIMIT: Set of limit value of general credit.


JACKPOT LIMIT: Set of limit value of Jackpot.
MACHINE SETUP> BILL/COIN ACCEPTOR SETUP

PROTOCOL: Setting of type of Bill acceptor.


Supported protocols: PULSE, APEX/MATRIX, CCNET, SSP, ICT, ID-003.

User's guide

written by http://www.simtech.com.ua

Multi Gaminator block type


MACHINE SETUP> SET VOLLUME

VOLUME: Setting of volume is in the mode of game. For diminishing of


influence of hindrances on quality of sound it is recommended to put on a
level 7 highest.
To produce regulation of volume on the board of comptroller.
ADMINISTRATION> ENTER PASSWORD

ADMINISTRATION: For included in the mode of administrator enter a password.


Standard value of password AAAAAAAAAA.
ADMINISTRATION> CHANGE PASSWORD

CHANGE PASSWORD: For the change of standard password enter in this menu.
Enter a new password, will confirm Enter. You will memorize the entered
password, renewal of the lost password is possible only in a service-center!

User's guide

written by http://www.simtech.com.ua

Multi Gaminator block type


ADMINISTRATION> GAME SELECTOR

VERSION STRING: Version, represented in the overhead right corner of basic


screen of the program in the playing mode. A value can be changed on any in a
limit IXXX.
Game1 Game10: Games, represented on the screen. At the independent drafting
of set it is possible to choose from listed above than slotovykh games. The
choice of games in the menu of choice of the basic playing mode looks so:
Game1 HOLD1
Game2 HOLD2
Game3 HOLD3
Game4 HOLD4
Game5 HOLD5
after changing by the START:
Game6 HOLD1
Game7 HOLD2
Game8 HOLD3
Game9 HOLD4
Game10 HOLD5
MULTIGAME VERSION: Versions, proper the set of original versions of games
Cool Fire I Novomatic. Changing the value of this point, the sets of games
change automatically Game1 Game10 and version number in the corner of basic
playing screen.
ADMINISTRATION> INITIALIZATION

DENOMINATION: Setting of credit cost is in a money.


MAXIMUM BET PER ROW: Setting of maximally possible rate on a line.
KEY INPUT: Setting of permission of raising of credit from the key.
CHANGE PASSWORD: Changing of password with a menu INIT.

User's guide

written by http://www.simtech.com.ua

Multi Gaminator block type


After setting of necessary parameters will turn off an automat and will include in 10 seconds after a
shutdown. T uning will be saved.

Connecting of bill acceptor on protocol


General information
Recommended type of bill acceptor: Mfl-0386 (validation head Mflv-2110, power
interface Flp-1710). Such bill acceptor (with power interface 1710) unites with a
block the special interface cable, containing the microcircuit of concordance of
levels of informative signals. Bill acceptor with power interface 2810 unite with a
block an interface cable without the microcircuit of concordance (power interface
2810 corresponds standard com-port of block).

Pin out of bill acceptor connector


Appearance

12

Setting of conclusions

Contact

Setting

1
2
3
4
5
6
7
8
9
10
11
12
Setting of conclusions
# of pin
1
2
3
4
5
6
7
8
9

User's guide

+12 V
M.RES
+12 V (INTERFACE)
GND
LED+
NC
GND
TXD
RXD
NC
LEDNC

Name
DCD
RxD
TxD
DTR
GND
DSR
RTS
CTS
RI

Type of signal
IN
OUT
IN
OUT
IN
OUT
IN
IN

Data type
Data carrier detect
Transmit data
Receive data
Data terminal ready
Ground
Data set ready
Request to send
Clear to send
Ring indicator

written by http://www.simtech.com.ua

Multi Gaminator block type


I will eat away on a system board
RRXD1
DDTR#1
DDSR#1
CCTS#1
2
1

9
RRI#1
RRTS#1
GND
TTXD1
DDCD#1

Accordance of socket on a system board an external socket


Pin on MotherBoard
1 (DDCD#1)
2 (RRXD1)
3 (TTXD1)
4 (DDTR#1)
5 (GND)
6 (DDSR#1)
7 (RRTS#1)
8 (CCTS#1)
9 (RRI#1)
10 -

User's guide

Pin of out connector


1 (DCD)
2 (RxD)
3 (TxD)
4 (DTR)
5 (GND)
6 (DSR)
7 (RTS)
8 (CTS)
9 (RI)
-

written by http://www.simtech.com.ua

Multi Gaminator block type


Connection of kupyuropriemnika (power interface 1710) with block.
For connection the done interface cable is used from bill acceptor ICT A7.

Below on a picture chart of connecting of interface cable and feed to the socket.
ATTENTION! I will eat away bill acceptor represented from the side of wires.

Black
White
Slant
1

Interface Cable

GND

Blue

+5 V

Red

+12 V
ATTENTION! On some models of interface cable a feed is required +12 volt in place of +5A.

Setting of wires of interface cable of


Pin1
Pin2
Pin3
Pin4
Pin5
Pin6
Pin7
Pin8

GND
TXD2
RXD2
Program
Reset
VCC
RXD1
TXD1

Blue

Red
Black
White

Note: For any connecting of other bill acceptor on protocol it is possible to use the
that interface cable of A7. For this purpose a socket retires for ICT A7, a socket
for a feed and reducer is added for the necessity of bill acceptor. Connecting of
bill acceptor is possible on the impulse of see 72-pin connector.
In a menu the necessary tuning get out for bill acceptor. For the maintainance of
information it is necessary to carry out a restart by the shutdown of feed.

User's guide

written by http://www.simtech.com.ua

Multi Gaminator block type

Addition 1
JAMMA 72pin connector

pin

1a
2a
3a
4a
5a
6a
7a
8a
9a
10a
11a
12a
13a
14a
15a
16a
17a
18a
19a
20a
21a
22a
23a
24a
25a
26a
27a
28a
29a
30a
31a
32a
33a
34a
35a
36a

Part Side

SPEAKER
HOLD1 SW
HOLD 2 SW
HOLD 3 SW
HOLD 4 SW
HOLD 5 SW
START SW
BET ONE SW
SELECT GAME SW
AUTO START SW
MAXBET SW
INFO SW
FRONT DOOR (SERVICE) SW

KEY ATTENDANT SW
COLLECT SW (PAYOUT BUTTON)

REMOTE&BILLS COUNTER
GAMES COUNTER
HANDPAY COUNTER
HOLD 1 LAMP
HOLD 2 LAMP
HOLD 3 LAMP
HOLD 4 LAMP
HOLD 5 LAMP
START LAMP
GND

Solder Side

1b
2b
3b
4b
5b
6b
7b
8b
9b
10b
11b
12b
13b
14b
15b
16b
17b
18b
19b
20b
21b
22b
23b
24b
25b
26b
27b
28b
29b
30b
31b
32b
33b
34b
35b
36b

GND
BILL ACCEPTOR (PULSE)

SELECT GAME LAMP


WBA LED
UPPER LAMP BLUE
UPPER LAMP WHITE
WIN COUNTER
BET COUNTER
BET ONE LAMP
MAXBET LAMP
COLLECT LAMP
AUTO START LAMP
INFO LAMP
GND

SW - switch, the button of vehicle is connected to the pay of controller through


socket JAMMA 72pin.
LAMP a lamp is proper the button of vehicle.
COUNTER outputs of meters.
FRONT DOOR (SERVICE) SW normally-opened contact of door, if a door is opened
connected to the GND.

User's guide

written by http://www.simtech.com.ua

Potrebbero piacerti anche