Sei sulla pagina 1di 2

321-56867-21A Sep.

2009

Menu Map Sheet

Press
or
menu option.

For details on the organization of the menu settings and the method of operation of the
menu, see "3. MENU SETTINGS" (^ page 40).

STAND
POURING

Press
[MENU/ENTER].

P.77

General weighing mode

Refers to a page in the instruction manual.

Press

The default settings (settings when the menu is reset)

to confirm.

WIN|.U

WIN-

WIN-.U

WindowsDirect communication function

APL.FUNC

PCS

SAMPLE

Item number
~

PERCENT

SAMPLE

100% reference

Piece counting

Percentage weighing

OPTION
FORMULA

TOOLS
Other functions

WIN|

WIN|.U

WIN-

WIN-.U

P.111

WindowsDirect communication function

APL.PRN
P.111

Press [PRINT]
for 3 sec.

Application output

AUTO.PRN

LD. .
LD.UL.
LD. .Z
LD.UL.Z
LD.OK.

Auto print function

P.71

Zero tracking function

Application
function mode

Weight display

P.77

Pouring mode

WIN|
Z.TRC

Press
to proceed to the next
menu option.

Data Output Menu

Main Menu
Weight display

Press
to return to the previous menu option.
(Pressing
for around 3 seconds during menu
operation returns you to the weighing mode.)

to search for the

TARGT

TG.VAL

CHECK.W

OVR.RNG
HI.LIM
LO.LIM
UND.RNG

Checkweighing
mode

PARAM.W

SEQ.PRN

Continuous output
function

P.96

Output timing change function

PRINT.F

COMM.SET

Target value

Communication
settings

Permissible range
Checkweighing range
upper limit
Pass range upper limit
Pass range lower limit

FAST

BAND

System

POINT

Decimal point
indication

Zero or negative value

MODE.1
MODE.2
MODE.3
MODE.4
MODE.5

Key operation

0.5D
1D
10D
50D
100D
1000D

P.129

P.126

Standard settings (MODE1 - MODE5)

MODE.U

BPS
Baud rate

P.80

P.79

PARITY
Parity

B. 300
B. 600
B.1200
B.2400
B.4800
B.9600
B. 19.2K
B. 38.4K

[300]

P.NONE
P.ODD
P.EVEN

None

S. 1
S. 2

1 bit

HS.OFF
HS.HW
HS.SW
H.S.TIM

None

[600]
[1200]
[2400]

P.127

[4800]
[9600]
[19.2 K]
[38.4 K]

P.127

Odd
Even

PERIOD
Period

STOP

P.42

AUTO.OFF

Auto power-off

BC.LIT

Backlight
(TXB series only)

Stop bit

HAND.SHK
Handshake

P.138
P.140

AUTO

SEM.AUTO

DF.
DF.
DF.
DF.

D.FORM

Weighing mode

OFF display

Data format

P.139

MANU

1
2
3
4

P.127

2 bits

Hardware
Software

P.127

Timer
Data format 1
Data format 2
Data format 3
Data format 4

P.128

DF.FRE

All segments lit

D. HEAD

Head byte

D. LEN

Data length

Free format

BAL.ID

Balance ID

P.69

PASS.WRD

Password

P.141

COND.OUT

Menu settings output

P.53

Menu reset

P.51

RESET

P.108

No filter

COMMA

START

50%

SOON

User-specified settings

Comma

Start display

RET.50

On OK

Fast

Stability detection range

SYSTEM

P.104

Checkweighing range
lower limit

Stability mark

RET. 0

Zero return
judgment

On -0Ld

MANU
NO.FIL

P.92
Specific percentage
reference

STB.MK

Weighing
parameters

Z.RET

On 0Ld

P.106

P.102

LM.VAL

On -Ld

P.87

Formulation

Target mode

On Ld

DELIM

CR
LF
CR+LF
COMMA

Delimiter

CR
LF
CR+LF
Comma

WIN|

P.128

WIN|.U

WindowsDirect communication function

WIN-

Unit setting menu


Weight display

Press [UNIT]
for 3 sec.

UNIT- g g
UNIT- mg #1
UNIT- kg #2
UNIT- ct

Calibration menu
P.83

Other units cannot be selected in some


countries due to legal restrictions.
#1: mg cannot be selected on models
whose minimum indication is 10 mg or
greater.
#2: kg cannot be selected on the TWC***L
and TXC***L.

UNIT-U

CONV.K

User-specified
units

Minimum indication

MIN.D
Conversion factors

P.84
P.85

CAL.EXE
Weight display

Calibration

E.CAL
E.TEST
I.CAL
I.TEST

Press [CAL]
for 3 sec.

GLP.OUT
P.CAL

WIN-.U

Zero / tare menu


Span calibration using
an external weight
Calibration check using
an external weight
Span calibration using
the internal weight
(TW series only)
Calibration check using
the internal weight
(TW series only)

P.57
P.62

Weight display

P.56
P.60

GLP output function

P.142

Calibration of the internal


weight (TW series only)

P.64

Press [O/T]
for 3 sec.

Z.TRC

Zero tracking function

P.71

A.TARE

Auto tare function

P.74

A.ZERO

Auto zero function

P.72

TARE.F

SOON

Zero / tare timing


change function

P.75

Operation Control Panel

Operation keys

Display panel

Key

No.

5 [MENU/ENTER]
6UNIT
6
[UNIT]

Press Once and Release

Press and Hold for About 3 Seconds

[BREAK]

Switches between the operation and standby modes

[CAL]

Performs calibration

Enters the calibration menu

[O/T]

Tares the balance (setting it to zero)

Opens the zero / tare menu

[PRINT]

Outputs the weight reading to a peripheral device (printer or


PC)

Opens the data output menu

Menu operation keys


7
7FUNC
[FUNC]
2
CAL

1
BREAK

3
O/T

4
PRINT

Operation keys
With the TXB series,

Menu operation keys

is provided.

Display panel
1

No.
1

Display

Name
Battery symbol

l m

Description

See:

Lit when the weight reading is stable. Also lit when the option currently set in
menu setting is displayed.

^ P.33

Press and Hold for About 3 Seconds

Displays the main menu

Shows the menu displayed last

[UNIT]

In the weighing mode: Used to select the unit


When piece counting: Displays the unit weight
When performing percentage weighing:
Displays the reference weight

In the weighing mode: Opens the unit setting menu


When piece counting: Used to select the item number
When performing percentage weighing:
Used to select the percentage reference

[FUNC]

Switches between the weighing mode and the application


function mode

Selects the minimum number of displayed digits

[Res]

The response of the display is increased.

[Stb]

The stability of the display is increased.

No.

Press Once and Release

[MENU/ENTER]

9Stb
9
[Stb]

8Res
8
[Res]

Key

No.

Display

Name

Description

See:

Auto print symbol

Lit when the Auto Print function is set.

^ P.108

Win symbol

Lit when the WindowsDirect communication function has been set.

^ P.112

Communication symbol

Indicates that data is being exchanged with an external device.

Comparator symbol

When the comparator function (Checkweighing) has been set, indicates the
comparison judgment.

^ P.102

Stability mark

Lit when the weight reading is stable. Lit when the option currently set in menu
setting is displayed.

^ P.48
^ P.79

Minus symbol

Lit when the weight reading is negative.

Ready symbol

Lit during the standby mode (TX series only). Also, during weighing, lit to
indicate the ready to weigh status, for example when using the formulation
function.

^ P.43
^ P.96

Number symbol

Lit when it is possible to enter numerical values.

^ P.49

Hold symbol

Lit when a value that is not the real-time weight reading (for example the
indication of the unit weight in piece counting) is displayed.

^ P.90
^ P.95

Net weight symbol

Indicates that the weight reading displayed in mixing measurement (formulation)


is the net weight of the current component with the weight of the container and
prior components. Also indicates that a measuring operation is in progress.

^ P.97

Gross weight symbol

Indicates that the weight reading displayed in mixing measurement (formulation)


is the total weight of all of the components of the mixture with the weight of the
container subtracted.

^ P.97

Zero tracking symbol

Lit when the zero tracking function is set ON.

^ P.71

Weight symbol

This symbol is lit during calibration.

^ P.57
^ P.62

Item number indication

Shows the item number in the piece counting mode.

^ P.90

Easy setting indicator

Indicates what level the response and stability are currently set to.

^ P.78

Inverse triangle symbol

^ P.50

Pouring symbol

Lit when the pouring mode is set.

^ P.77

When this symbol is lit when changing the position of the decimal point in the
conversion factor with the user-specified units, numerical values can be entered
without a decimal point.

Formulation symbol

Lit during mixing measurement (formulation) operations.

^ P.96

Piece counting symbol

Lit while the piece counting mode is in effect.

^ P.90

Menu lock symbol

Lit while the menu is locked.

^ P.52

Specific percentage weighing


symbol

Lit when the specific percentage reference has been set for percentage
weighing.

^ P.94

Menu operation key symbol

During menu operation, indicates which of the menu operation keys can be
used.

^ P.47

Percentage weighing symbol

Lit during percentage weighing.

^ P.95

Potrebbero piacerti anche