High Performance
¥ Sensitive, high-speed analysis with excellent repeatability
Application Systems
¥ Pretreatment units (headspace gas analysis, pyrolysis) ¥ Distillation GC, PONA-
GC, trace sulfur analysis
Easy Operation
¥ Self-diagnostic functions and easy-to-see large display ¥ Carrier gas constant
linear velocity mode
Data Management
¥ GCSolution Ver. 2 workstation ¥ Simple operation and comprehensive basic
functions enhance analysis productivity ¥ GLP/GMP compliant, network-compatible
Flexibility
¥ Simultaneously mount up to three injection units and four detectors ¥ Dual
injection system
3
Superb Basic Functions Promise Fast and
High Performance
Grob Test Mixture Analysis
Ultimate Repeatability
A new-generation AFC (Advanced Flow Controller) features rapid response and
temperature correction functions, plus an improved sample injection unit and
column oven all work together to achieve excellent repeatability for retention
time, peak area, and peak height.
AREA
Mean
Standard deviation
CV%
1 76579 76843 76975 76873 76294 76396 76216 76362 76371 76725 76394.0 174.815
0.229
2 60390 60666 60775 60673 60249 60362 60177 60338 60346 60552 60337.3 126.709
0.210
3 76285 76546 76693 76505 76053 76178 76037 76150 76113 76401 76155.3 132.031
0.173
4 68766 69022 69148 69003 68502 68639 68466 68590 68635 68930 68627.0 164.275
0.239
5 53094 53314 53331 53244 52872 53010 52850 52941 52976 53225 52979.0 134.922
0.255
6 54525 54785 54803 54678 54351 54516 54382 54444 54432 54675 54466.7 116.704
0.214
7 68680 69058 68954 68870 68625 68849 68651 68735 68733 68936 68754.8 118.488
0.172
8 57310 57584 57576 57487 57169 57368 57170 57274 57318 57523 57303.7 133.666
0.233
World-beating Sensitivity
Sensitivity is Up
fivefold!!
(In comparison with Shimadzu GC-17A)
Photomultiplier
Time (min.)
Time (min.)
4
Accurate Analysis Results
GAS CHROMATOGRAPH
Greater Speed
High-speed analysis with a narrow-bore capillary column reduces operator time and
increases samplethroughput. But it places stringent demands on inlet design and
carrier gas pneumatics (through high column back pressures and high split flow
rates). The new-generation AFC digital flow controller supports high-speed
analysis at a maximum pressure of 970 kPa and 1200 mL/minute maximum flow rate.
High-speed Analysis of Coffee Flavoring
Analysis time of previous model
DB-WAX 0.25mm✕60m, 0.25µm ( He 25cm/s )
60 minutes
6 12 Rtx-WAX 0.1mm✕20m, 0.1µm ( He 25cm/s )
20 minutes
3 5
4 ms sampling 40 ms sampling
Time (min.)
5
Easy Operation Saves Time and Total
Easy Operation
An information rich, large display is provided to show a lot of information. The
text and graphic screen lets you set the analysis conditions quickly and easily.
The built-in help functions make operation training almost unnecessary after the
instrument in installed. Digital setting of all parameters, including temperatures
and flowrates, allows accurate reproduction of the analysis conditions.
Large Display
Large Display
Graphic user interface Text display Built-in help functions Chromatogram display
Self-diagnostic Functions
Unit control check Hardware diagnosis Save and check diagnosis log
6
Cost
GAS CHROMATOGRAPH
(Pesticides Analysis)
Comparison of the GC-FID chromatogram and GCMS-QP2010 total ion chromatogram (TIC)
is also simple in the carrier gas constant linear velocity mode. Using the same
type of column and setting the same carrier gas linear velocity values results in
a virtually identical separation profile. Comparison of GC-FID and GC/MS-TIC
Chromatograms (Grob Test Mixture Analysis)
GC-FID
4.0
5.0
6.0
7.0
8.0
9.0
10.0
11.0
12.0
min
GC/MS (TIC)
4.0
6.0
8.0
10.0
12.0
min
7
Unit Expandability Supports all Anal
Simultaneously Mount Up to Three Injection Units and Four Detectors*
Select from three injection units and five detector types to suit the needs of the
analysis and the target components. GCsolution allows up to four detectors to be
mounted simultaneously. Options such as injection units, detectors, and auto-
injectors can be easily added after installing the unit.
* The number of units which can simultaneously mount up is limited according to a
kind.
Top of GC-2010
8 7 6 5
4
For detectors
SPL-2010
• Standard unit for high-speed analysis with a narrow bore column. • Gas saver
function can restrict the amount of split gas used. • Support high-pressure
injection.
WBI-2010
OCI/PTV-2010
• Handles sample injection using both cold on-column and PTV methods. • Uses
inactive, heat-resistant quartz PTV inserts. • The optional simple OCI insert
permits use of a small-ID capillary column for the cold on-column method without a
0.53 mm id. pre-column press-tight connection. • Supports the analysis of
compounds with a high boiling point (straight-chain hydrocarbons with 100 carbon
number) .
3 2 1
8
ysis Types
Compact, Highly Sensitive Detector Range
The detectors have been re-designed to be more compact. All detectors can be
installed under the instrument top cover to allow easy mounting of each option and
pretreatment unit. Each detector incorporates an APC (Advanced Pressure
Controller) that permits digital setting of the detector gas flowrate.
TCD
TCD-2010
ECD-2010
ECD
9
GAS CHROMATOGRAPH
FPD
Flame Photometric Detector
FPD-2010
• For analysis of organic sulfur compounds and organic phosphorus compounds such
as residual pesticides and malodorous components. • Updated optics improve
sensitivity 5 times, compared with previous instruments. • Nozzle construction
prevents adhesion and decomposition of the sample. • Designed for compactness and
high maximum operating temperature (350°C). • No tools needed for filter
replacement.
Filter replacement
Collector
Collector replacement
FTD
Flame Thermionic Detector (NPD)
• For analysis of organic nitrogen compounds and organic phosphorus compounds such
as residual pesticides. • New collector construction allows collector replacement
without tools. • Optional alkali source regeneration kit saves running costs.
FTD-2010
Remove screw Replace collector
10
Shimadzu Gas Chromatograph Workstation
Data Explorer, ensures an intuitive common user interface that can be easily
learned.
GLP/GMP compliance
● Full support of user management functions and GC-2010 self-diagnostic functions
to enhance
Network-compatibility
● Promotes the efficient use of the network environment, such as in-office data
analysis ● Provides file sharing and centralized data management tools. (CLASS-
Agent)
and remote access from the office. (GCsolution Post-run software, pcANYWHERE)
11
User Interface
The latest Windows technologies offer multifunctionality and simple operation.
User interface including drag-and-drop and right-click menus offers quick and
intuitive operation
Assistant Bar
Data Explorer
12
Data Analysis / Report Generation
Builds on the popular Chromatopac and CLASS-GC10 basic functions, including
integration algorithms. Offers comprehensive functions for identification,
quantitation, data comparison, and report generation.
13
GLP/GMP-Functions
To be compliant with management requirements and regulations such as GLP/GMP, a
variety of sophisticated demands related to: analyzer reliability, method
development, analysis method validation, and electronic file management must be
satisfied to ensure data integrity GCsolution Ver. 2 features even further
strengthened validation-related and user management functions. A Part11
compatibility kit is available to provide full support for FDA 21 CFR Part 11
compatibility.
14
Network-compatibility
Using a network such as an in-house LAN or the Internet allows centralized data
management and the sharing of files containing data or analysis methods. In
addition to the basic workstation software, GCsolution offers a range of network
tools to enhance analysis efficiency.
Other office PC
Internet data browser (CLASS-Agent Web Manager)
Internet
PC Server DB PC
Database PC server
GC-LAN connection LAN adaptor Data acquisition over LAN (GC-LAN connection
software)
GC
Factory
GC GC
RS -23 2C
Analysis laboratory
PC
Eth erN
GCsolution Ver.2
ET -LA N
PC
Access to LAN PC
15
Analysis Systems for Every Application
Headspace Analysis System
¥ A sample sealed in a vial is heated for a certain time before the vapor phase in
the headspace is analyzed. ¥ Used to analyze the volatile components in solid or
liquid samples.
System Configuration (GC with headspace sampler)
¥ GC-2010 + AOC-5000
Analysis Applications
Pyrolysis System
¥ Decomposes samples at high temperatures and analyzes the pyrolytic decomposition
products. ¥ Used to analyze high molecular weight compounds such polymers,
forensic samples etc.
System Configuration (GC with double-shot pyrolyser)
Distillation GC System
¥ Measures the boiling point distribution of petroleum fractions using the
relationship between retention time and boiling point. ¥ Prints formatted reports
after analysis of distillation characteristics.
System Configuration (Distillation GC)
¥ Petroleum fractions
16
Direct injection mode
GC-2010 Specifications
■Column Oven
Temperature range: room temperature + 4¡C to 450¡C (using liquid CO2 gas*: -50¡C
to 450¡C) Dimensions: 280 (w) x 280 (H) x 175 (D) mm Oven volume: 13.7 L
Temperature accuracy: set value (K) ± 1% (calibration at 0.01¡C) Temperature
deviation: <2¡C max. (on 200 mm dia. circumference 30 mm from rear, 115V model)
Temperature variation coefficient: <0.01¡C/¡C Temperature program steps: Up to 20
(cooling program possible) Programmed rate setting range: -250 to 250¡C/min. Total
time for all steps: 9999.99 minutes max. * Optional parts are required to use
liquid CO2 gas.
■Injection Port
Dimensions: 515 (w) x 440 (H) x 530 (D) mm Weight: 30 kg (FID model) Power
requirements: AC100V/115V230V ±10%, 1800VA (Normal oven type) or 2600VA (High
power oven type), 50/60Hz
Temperature range: room temperature + 5¡C to 450¡C Heating rate: 50¡C to 450¡C
within 3 minutes Cooling rate: 450¡C to 50¡C within 8 minutes (for 50¡C column
temperature) Heating program: max. heating rate 250¡C/minute, heating in 7 steps
Switching possible between on-column and programmable temperature vaporizer
injection units (requires split piping re-connection between OCI and PTV) To keep
instrument specifications, max. 2 injection ports shall be heated simultaneously.
Four detectors can be installed simultaneously and individually temperature
controlled. Detector gas is electronically controlled by APC (Advanced Pressure
Control).
Flame Ionization Detector (FID) ■Detectors
Advanced Flow Controller (AFC) Pressure setting range: 0 to 970 kPa Programmable
steps: 7 (cooling program possible) Programmed rate setting range: -400 to 400
kPa/min. Split ratio setting range: 0 to 9999.9 Total flowrate setting range: 0 to
1200 mL/min. Column average linear velocity can be kept constant while temperature
is increasing.
17
GCMS-QP2010 Gas Chromatograph-Mass Spectrometer
The QP2010 provides optimum performance analysis for all GCMS measurements. High-
speed GCMS capability and optimum separation are standard with every QP2010. Our
GCMS with Lab Solutions software can analyze more unattended samples than any
other product. Unique system checking verifies ideal operation. QP2010 and GC-2010
continue the tradition of performance and maintenance simplicity - Shimadzu
trademarks. ¥ Scan Sensitivity over 60/1 for 1pg OFN ¥ Superior High-Speed GCMS. ¥
20 Temperature Ramps and patented Constant Linear Velocity for optimum separation.
¥ Front access for easy maintenance and direct probe for flexibility. ¥ Pump down
in under 4 minutes and input up to 15mL/min flow into the ion source. ¥ Optional
positive and negative chemical ionization. ¥ Optional direct inlet kit
7102 Riverwood Drive, Columbia, Maryland 21046, U.S.A. Phone: 1(410)381-1227 Fax.
1(410)381-1222 Toll Free: 1(800)477-1227
SHIMADZU DEUTSCHLAND GmbH
16 Science Park Drive #01-01 Singapore Science Park, Singapore 118227, Republic of
Singapore Phone: 65-778 6280 Fax. 65-779 2935
SHIMADZU SCIENTIFIC INSTRUMENTS (OCEANIA) PTY. LTD.
Units F, 10-16 South Street Rydalmere N.S.W. 2116, Australia Phone: 61(2)9684-4200
Fax. 61(2)9684-4055
SHIMADZU DO BRASIL COMERCIO LTDA.
Rua Cenno Sbrighi, 25, Agua Branca, Sao Paulo, CEP 05036-010, BRAZIL Phone:
(55)11-3611-1688 Fax. (55)11-3611-2209
SHIMADZU (HONG KONG) LIMITED
Suite 1028 Ocean Center, Harbour City, Tsim Sha Tsui, Kowloon HONG KONG Phone:
(852)2375-4979 Fax. (852)2199-7438
Overseas Offices
URL http://www.shimadzu.com