Cost Effective Tools for Finding the Fault Faster

and Reducing Outage Duration


Cooper Power Systems manufactures a line of S.T.A.R. Superior, Tough, And
Reliable faulted circuit indicators to fit your application.

Locate Faulted Sections of Cable Systems Fast, Reliably, and Accurately


Weve put many standard features* into the S.T.A.R.
Faulted Circuit Indicators (FCI) for maximum reliability and
simplified application.
See Feature Availability Chart on page 2 for a listing of each
model, its application, features, available options, and other
details.
S.T.A.R. Faulted Circuit Indicators from Cooper Power
Systems meet or exceed IEEE Std 495-1986 standard,
Guide for Testing Faulted Circuit Indicators.

Design features:
Inrush Restraint: Feature that eliminates false tripping by
ignoring inrush currents caused by reclosing operations of
protective devices on the system. A dead time of 200 ms
will activate the inrush restraint feature.
Low Pass Filter: Prevents the faulted circuit indicator
from tripping on high frequency transients like those
caused by cable capacitive discharges.
Temperature Compensation Circuitry: Assures accurate
and reliable performance over the entire specified
temperature range, -40 C to +85 C, per IEEE Std
495-1986 standard.
High/Low Trip Rating: Allows for simplified trip rating
selection based on the primary amperage rating of the
system. For example, select low for 200 A systems, and
high for 600 A systems.
Variable Trip Rating: Trip design that indicates a fault
when a significant rise in current, followed by a loss
of voltage, is detected (rather than a specific, static trip
setting). The variable trip rating applies to Pathfinder
models, and allows for a wide range of applications, as
well as a reduction in inventories, thus, saving money.

Battery Life Optimization Circuitry (BLOC): Ensures


maximum life for the battery powering the LED display.
Used in the PATHFINDER Test Point Reset (TPR) Faulted
Circuit Indicators (FCI), the BLOC feature will shut the
LED display off after 4 hours, but retains a record of fault
occurrence in memory, which can be interrogated by use
of the manual reset/testing tool. The event will remain
in memory until the unit is either manually reset or until
normal system power is restored.
Reset Restraint: Prevents the fault indicator from falsely
resetting due to feedback voltages of less than 80% of
the normal voltage measured at the test point.
Current Transformer Design: Eliminates false tripping
due to adjacent cable conditions.
Single Clampstick Installation: Allows for quick and
simple installation with the use of a single clampstick.
FISHEYE Display: Provides 180 visual indication of FCI
operation. This unique orange reflective target designates a
fault and a black target designates a normal condition.
Test Point Adapter Kit: For applying Test Point FCI
models on non-standard test points. Kit provides metal
contact and hex wrench, for retrofitting older-style test
points, to allow installation of the Test Point FCI (Adapter
kit sold separately).
Manual Testing/Reset Tool: This simple tool allows the
user to either reset a tripped FCI or to interrogate an FCI
that is equipped to store a fault occurrence in memory,
such as the PATHFINDER TPR FCI.
Universal Power Supply: For low voltage reset model,
allows power source to be at any secondary voltage (120,
208, 240, and 277 Vac). (Standard LVR model requires
120 Vac.)
* Not all features available on all FCI models. Refer to page 2 and the
catalog section listed for complete details on each S.T.A.R. FCI.

One Cooper | www.cooperpower.com | Online


One Cooper | www.cooperpower.com | Online

S.T.A.R. Faulted Circuit Indicator

Feature Availability Chart

PATHFINDER PATHFINDER
Test
Current
Model/Type
Point
Reset
Base Part Numbers
Catalog Section
Application
Trip Rating

Standard
Features

Display Type

Available
Options

Power
Requirements

Reset
Requirements

Overhead
Underground/Pad-mounted
High/Low Trip Rating
Variable Trip Rating (PATHFINDER)
Auto Adjusting Trip
Inrush Restraint
Temperature Compensation
Low Pass Filter
Battery Life Optimization Circuitry
Reset Restraint
Single Clampstick Installation
Automatic Reset
Open-Core CT Design
Closed-Core CT Design
Reed Switch Design
LED Display
FISHEYE Display
Flag Display
Auxiliary Contacts for SCADA
Remote FISHEYE Display
Small Remote Display
Remote Fiber Optic Display
Manual Testing/Reset Tool
Test Point Adapter Kit
Universal Power Supply
Battery Powered
Line Powered
Secondary Source
Externally Replaceable Battery
2.4 kV L-G
5 kV L-G
7.2 kV L-G
90 VAC
2.4 Amps Continuous
2.0 Amps Continuous
Other

STVT
320-42

SCVT
320-77

Test
Point
Reset
STLO
STHI
320-40

Current Electrostatic
Reset
Reset
SCLO
SELO
SCHI
SEHI
320-75
320-60

Low
Voltage
Reset
SLLO
SLHI
320-50

Programmable
Delayed
Reset
SDOH
320-95

Optional

Standard

Optional

Programmable

= Product/Feature unique to the S.T.A.R. Faulted Circuit Indicator

Cooper Power Systems


2300 Badger Drive
Waukesha, WI 53188
P: 877.CPS.INFO

One Cooper | www.cooperpower.com | Online

B320-03013 1212

Cooper Power Systems, S.T.A.R., PATHFINDER, FISHEYE, and BLOC are valuable trademarks of Cooper Industries in the U.S. and other countries.
You are not permitted to use the Cooper Trademarks without the prior written consent of Cooper Industries.
2012 Cooper Industries. All Rights Reserved.

Potrebbero piacerti anche