Sei sulla pagina 1di 21

Printed Date: 29/07/2014

Job: CLINICA CHILPANCINGO GUERRERO - IMSS


Mark: VE-01

Performance Corrections
Elevation (ft)

Model: SWB-206-4

4,111

Airstream Temp.(F)

70

Backward Inclined Centrifugal Utility Fan

Air Density (ft3)

0.064

Drive Loss (%)

17.7

Inlet Conditions

Standard

Outlet Conditions

Standard

Actual Performance
Requested Volume (CFM)

350

Actual Volume (CFM)

350

External SP (in. wg)

0.2

Total SP (in. wg)

0.2

OV (ft/min)

554

Fan RPM

1978

Operating Power (hp)

0.15

Tip Speed (ft/min)

5,892

Static Eff. (%)

Fan Configuration
Quantity

Arrangement

10

Rotation

CW

Discharge Position

TH

Drive Type

Belt

Dimensional
Weight w/o Acc's (lb)

139

Weight w/ Acc's (lb)

146

Max T Motor Frame Size

145

Motor
Motor Mounted

Yes

Size (hp)

1/4

V/C/P

115/60/1

Enclosure

ODP

Motor RPM

1725

Windings

NEC FLA* (Amps)

5.8

Motor Pulley Type

Adjustable

Notes:

Sound Power by Octave Band


Sound
Data
Inlet

62.5

125

250

500

82

73

70

71

CAPS 4.15.1146

1000 2000 4000 8000 LwA


67

62

58

50

72

dBA Sones
61

10.6

All dimensions shown are in units of in.


*FLA - based on tables 150 or 148 of National Electrical
Code 2002. Actual motor FLA may vary, for sizing thermal
overload, consult factory.
LwA - A weighted sound power level, based on ANSI S1.4
dBA - A weighted sound pressure level, based on 11.5 dB
attenuation per Octave band at 5 ft - dBA levels are not
licensed by AMCA International
Sones - calculated using AMCA 301 at 5 ft

C:\Users\tcaballero\Desktop\CLINICA CHILPANCINGO GUERRERO - IMSS.gfcj

Page 1 of 21

Printed Date: 29/07/2014


Job: CLINICA CHILPANCINGO GUERRERO - IMSS
Mark: VE-01

Model: SWB-206-4
Backward Inclined Centrifugal Utility Fan
Standard Construction Features:
HOUSING: Steel housing with Lock-seam construction - Unit support angles with
prepunched mounting holes - Adjustable motor plate - Corrosion resistant
fasteners - Steel components are phosphatized and coated

Options & Accessories:


High Efficient Motor - meets Greenheck High Efficiency Table
Steel Scroll Housing
Aluminum Wheel Construction, Mill Finish
Steel Inlet Cone
Isolators (Qty:4), Rubber Mount for Indoor/Outdoor use, Single Deflection 0.25 in.
(PN: 370048)
Weatherhood
Coated with Permatector, Concrete Gray-RAL 7023, Standard Coating on Entire
Fan
Unit Warranty: 1 Yr (Standard)

CAPS 4.15.1146

C:\Users\tcaballero\Desktop\CLINICA CHILPANCINGO GUERRERO - IMSS.gfcj

Page 2 of 21

Printed Date: 29/07/2014


Job: CLINICA CHILPANCINGO GUERRERO - IMSS
Mark: VE-01

SWB-206-4

Backward Inclined Centrifugal Utility Fan

9.75

HOUSING
CENTERLINE

SHAFT
CENTERLINE

11.25

8.00

HOUSING
CENTERLINE

11
INLET

8.00

5.81

0.5
4 Holes
19.44

INLET

OUTLET
CONNECTIONS

FAN FOOTPRINT

NOT DRAWN TO SCALE

31.75
18.75

9.75
24.87

8.63

6.88
2.01

HOUSING
CENTERLINE

WEATHERHOOD

11.5

11.00
26.63

15.13

16.88
26.75

END VIEW

SIDE VIEW
*SIDE VIEW IS VIEWED FROM DRIVE SIDE

Notes: All dimensions shown are in units of in.

CAPS 4.15.1146

C:\Users\tcaballero\Desktop\CLINICA CHILPANCINGO GUERRERO - IMSS.gfcj

Page 3 of 21

Printed Date: 29/07/2014


Job: CLINICA CHILPANCINGO GUERRERO - IMSS
Mark: VE-02
24.38

Model: GB-091-4
Belt Drive Centrifugal Roof Exhaust Fan

23.75

Dimensional
Quantity

Weight w/o Acc's (lb)

56

Weight w/ Acc's (lb)

58

Max T Motor Frame Size


Roof Opening (in.)

4.38

56

19

14.5 x 14.5

1.75

Reference assembly view drawings for actual


dimensions with mounted accessories
*Overall height may be greater depending on motor

Performance
Requested Volume (CFM)

340

Actual Volume (CFM)

340

External SP (in. wg)

0.2

Total SP (in. wg)

0.2

Fan RPM

797

Operating Power (hp)

0.04

Elevation (ft)

4,111

Airstream Temp.(F)

70

Air Density (ft3)

0.064

Drive Loss (%)

50.0

Tip Speed (ft/min)

2,335

Static Eff. (%)

50

Motor
Motor Mounted

Yes

Size (hp)
V/C/P

1/4
115/60/1

Enclosure

ODP

Motor RPM

1725

Windings
NEC FLA* (Amps)

1
5.8

Notes:

Sound Power by Octave Band


Sound
Data
Inlet

62.5

125

250

500

66

63

58

54

CAPS 4.15.1146

1000 2000 4000 8000 LwA


49

46

41

40

57

dBA Sones
45

4.0

All dimensions shown are in units of in.


*FLA - based on tables 150 or 148 of National Electrical
Code 2002. Actual motor FLA may vary, for sizing thermal
overload, consult factory.
LwA - A weighted sound power level, based on ANSI S1.4
dBA - A weighted sound pressure level, based on 11.5 dB
attenuation per Octave band at 5 ft - dBA levels are not
licensed by AMCA International
Sones - calculated using AMCA 301 at 5 ft

C:\Users\tcaballero\Desktop\CLINICA CHILPANCINGO GUERRERO - IMSS.gfcj

Page 4 of 21

Printed Date: 29/07/2014


Job: CLINICA CHILPANCINGO GUERRERO - IMSS
Mark: VE-02

Model: GB-091-4
Belt Drive Centrifugal Roof Exhaust Fan
Standard Construction Features:
- Aluminum housing - Backward inclined aluminum wheel - Curb cap with
prepunched mounting holes - Motor and drives isolated on shock mounts Birdscreen - Ball bearing motors - Adjustable motor pulley - Adjustable motor
plate - Fan shaft mounted in ball bearing pillow blocks - Bearings meet or exceed
temperature rating of fan - Static resistant belts - Corrosion resistant fasteners Sizes 141 and larger have internal Lifting lugs

Options & Accessories:


High Efficient Motor - meets Greenheck High Efficiency Table
Switch, NEMA-1, Toggle, Junction Box Mounted & Wired
Unit Warranty: 1 Yr (Standard)

CAPS 4.15.1146

C:\Users\tcaballero\Desktop\CLINICA CHILPANCINGO GUERRERO - IMSS.gfcj

Page 5 of 21

Printed Date: 29/07/2014


Job: CLINICA CHILPANCINGO GUERRERO - IMSS
Mark: VE-03

Performance Corrections
Elevation (ft)

Model: SWB-206-4

4,111

Airstream Temp.(F)

70

Backward Inclined Centrifugal Utility Fan

Air Density (ft3)

0.064

Drive Loss (%)

30.9

Inlet Conditions

Standard

Outlet Conditions

Standard

Actual Performance
Requested Volume (CFM)

250

Actual Volume (CFM)

250

External SP (in. wg)

0.2

Total SP (in. wg)

0.2

OV (ft/min)

396

Fan RPM

1467

Operating Power (hp)

0.07

Tip Speed (ft/min)

4,370

Static Eff. (%)

15

Fan Configuration
Quantity

Arrangement

10

Rotation

CW

Discharge Position

TH

Drive Type

Belt

Dimensional
Weight w/o Acc's (lb)

139

Weight w/ Acc's (lb)

146

Max T Motor Frame Size

145

Motor
Motor Mounted

Yes

Size (hp)

1/4

V/C/P

115/60/1

Enclosure

ODP

Motor RPM

1725

Windings

NEC FLA* (Amps)

5.8

Motor Pulley Type

Adjustable

Notes:

Sound Power by Octave Band


Sound
Data
Inlet

62.5

125

250

500

80

74

65

64

CAPS 4.15.1146

1000 2000 4000 8000 LwA


60

55

48

39

66

dBA Sones
55

7.5

All dimensions shown are in units of in.


*FLA - based on tables 150 or 148 of National Electrical
Code 2002. Actual motor FLA may vary, for sizing thermal
overload, consult factory.
LwA - A weighted sound power level, based on ANSI S1.4
dBA - A weighted sound pressure level, based on 11.5 dB
attenuation per Octave band at 5 ft - dBA levels are not
licensed by AMCA International
Sones - calculated using AMCA 301 at 5 ft

C:\Users\tcaballero\Desktop\CLINICA CHILPANCINGO GUERRERO - IMSS.gfcj

Page 6 of 21

Printed Date: 29/07/2014


Job: CLINICA CHILPANCINGO GUERRERO - IMSS
Mark: VE-03

Model: SWB-206-4
Backward Inclined Centrifugal Utility Fan
Standard Construction Features:
HOUSING: Steel housing with Lock-seam construction - Unit support angles with
prepunched mounting holes - Adjustable motor plate - Corrosion resistant
fasteners - Steel components are phosphatized and coated

Options & Accessories:


High Efficient Motor - meets Greenheck High Efficiency Table
Steel Scroll Housing
Aluminum Wheel Construction, Mill Finish
Steel Inlet Cone
Isolators (Qty:4), Rubber Mount for Indoor/Outdoor use, Single Deflection 0.25 in.
(PN: 370048)
Weatherhood
Coated with Permatector, Concrete Gray-RAL 7023, Standard Coating on Entire
Fan
Unit Warranty: 1 Yr (Standard)

CAPS 4.15.1146

C:\Users\tcaballero\Desktop\CLINICA CHILPANCINGO GUERRERO - IMSS.gfcj

Page 7 of 21

Printed Date: 29/07/2014


Job: CLINICA CHILPANCINGO GUERRERO - IMSS
Mark: VE-03

SWB-206-4

Backward Inclined Centrifugal Utility Fan

9.75

HOUSING
CENTERLINE

SHAFT
CENTERLINE

11.25

8.00

HOUSING
CENTERLINE

11
INLET

8.00

5.81

0.5
4 Holes
19.44

INLET

OUTLET
CONNECTIONS

FAN FOOTPRINT

NOT DRAWN TO SCALE

31.75
18.75

9.75
24.87

8.63

6.88
2.01

HOUSING
CENTERLINE

WEATHERHOOD

11.5

11.00
26.63

15.13

16.88
26.75

END VIEW

SIDE VIEW
*SIDE VIEW IS VIEWED FROM DRIVE SIDE

Notes: All dimensions shown are in units of in.

CAPS 4.15.1146

C:\Users\tcaballero\Desktop\CLINICA CHILPANCINGO GUERRERO - IMSS.gfcj

Page 8 of 21

Printed Date: 29/07/2014


Job: CLINICA CHILPANCINGO GUERRERO - IMSS
Mark: VE-04

Performance Corrections
Elevation (ft)

Model: SWB-206-4

4,111

Airstream Temp.(F)

70

Backward Inclined Centrifugal Utility Fan

Air Density (ft3)

0.064

Drive Loss (%)

33.1

Inlet Conditions

Standard

Outlet Conditions

Standard

Actual Performance
Requested Volume (CFM)

240

Actual Volume (CFM)

240

External SP (in. wg)

0.2

Total SP (in. wg)

0.2

OV (ft/min)

380

Fan RPM

1417

Operating Power (hp)

0.07

Tip Speed (ft/min)

4,221

Static Eff. (%)

16

Fan Configuration
Quantity

Arrangement

10

Rotation

CW

Discharge Position

TH

Drive Type

Belt

Dimensional
Weight w/o Acc's (lb)

139

Weight w/ Acc's (lb)

146

Max T Motor Frame Size

145

Motor
Motor Mounted

Yes

Size (hp)

1/4

V/C/P

115/60/1

Enclosure

ODP

Motor RPM

1725

Windings

NEC FLA* (Amps)

5.8

Motor Pulley Type

Adjustable

Notes:

Sound Power by Octave Band


Sound
Data
Inlet

62.5

125

250

500

80

74

65

64

CAPS 4.15.1146

1000 2000 4000 8000 LwA


59

54

47

38

66

dBA Sones
54

7.3

All dimensions shown are in units of in.


*FLA - based on tables 150 or 148 of National Electrical
Code 2002. Actual motor FLA may vary, for sizing thermal
overload, consult factory.
LwA - A weighted sound power level, based on ANSI S1.4
dBA - A weighted sound pressure level, based on 11.5 dB
attenuation per Octave band at 5 ft - dBA levels are not
licensed by AMCA International
Sones - calculated using AMCA 301 at 5 ft

C:\Users\tcaballero\Desktop\CLINICA CHILPANCINGO GUERRERO - IMSS.gfcj

Page 9 of 21

Printed Date: 29/07/2014


Job: CLINICA CHILPANCINGO GUERRERO - IMSS
Mark: VE-04

Model: SWB-206-4
Backward Inclined Centrifugal Utility Fan
Standard Construction Features:
HOUSING: Steel housing with Lock-seam construction - Unit support angles with
prepunched mounting holes - Adjustable motor plate - Corrosion resistant
fasteners - Steel components are phosphatized and coated

Options & Accessories:


High Efficient Motor - meets Greenheck High Efficiency Table
Steel Scroll Housing
Aluminum Wheel Construction, Mill Finish
Steel Inlet Cone
Isolators (Qty:4), Rubber Mount for Indoor/Outdoor use, Single Deflection 0.25 in.
(PN: 370048)
Weatherhood
Coated with Permatector, Concrete Gray-RAL 7023, Standard Coating on Entire
Fan
Unit Warranty: 1 Yr (Standard)

CAPS 4.15.1146

C:\Users\tcaballero\Desktop\CLINICA CHILPANCINGO GUERRERO - IMSS.gfcj

Page 10 of 21

Printed Date: 29/07/2014


Job: CLINICA CHILPANCINGO GUERRERO - IMSS
Mark: VE-04

SWB-206-4

Backward Inclined Centrifugal Utility Fan

9.75

HOUSING
CENTERLINE

SHAFT
CENTERLINE

11.25

8.00

HOUSING
CENTERLINE

11
INLET

8.00

5.81

0.5
4 Holes
19.44

INLET

OUTLET
CONNECTIONS

FAN FOOTPRINT

NOT DRAWN TO SCALE

31.75
18.75

9.75
24.87

8.63

6.88
2.01

HOUSING
CENTERLINE

WEATHERHOOD

11.5

11.00
26.63

15.13

16.88
26.75

END VIEW

SIDE VIEW
*SIDE VIEW IS VIEWED FROM DRIVE SIDE

Notes: All dimensions shown are in units of in.

CAPS 4.15.1146

C:\Users\tcaballero\Desktop\CLINICA CHILPANCINGO GUERRERO - IMSS.gfcj

Page 11 of 21

Printed Date: 29/07/2014


Job: CLINICA CHILPANCINGO GUERRERO - IMSS
Mark: VE-05
24.38

Model: GB-071-6
Belt Drive Centrifugal Roof Exhaust Fan

23.75

Dimensional
Quantity

Weight w/o Acc's (lb)

55

Weight w/ Acc's (lb)

57

Max T Motor Frame Size


Roof Opening (in.)

4.38

56

19

14.5 x 14.5

1.75

Reference assembly view drawings for actual


dimensions with mounted accessories
*Overall height may be greater depending on motor

Performance
Requested Volume (CFM)

120

Actual Volume (CFM)

120

External SP (in. wg)

0.2

Total SP (in. wg)

0.2

Fan RPM

898

Operating Power (hp)

0.03

Elevation (ft)

4,111

Airstream Temp.(F)

70

Air Density (ft3)

0.064

Drive Loss (%)

50.0

Tip Speed (ft/min)

2,631

Static Eff. (%)

25

Motor
Motor Mounted

Yes

Size (hp)
V/C/P

1/6
115/60/1

Enclosure

ODP

Motor RPM

1725

Windings
NEC FLA* (Amps)

1
4.4

Notes:

Sound Power by Octave Band


Sound
Data
Inlet

62.5

125

250

500

62

58

58

50

CAPS 4.15.1146

1000 2000 4000 8000 LwA


46

38

34

30

53

dBA Sones
42

3.0

All dimensions shown are in units of in.


*FLA - based on tables 150 or 148 of National Electrical
Code 2002. Actual motor FLA may vary, for sizing thermal
overload, consult factory.
LwA - A weighted sound power level, based on ANSI S1.4
dBA - A weighted sound pressure level, based on 11.5 dB
attenuation per Octave band at 5 ft - dBA levels are not
licensed by AMCA International
Sones - calculated using AMCA 301 at 5 ft

C:\Users\tcaballero\Desktop\CLINICA CHILPANCINGO GUERRERO - IMSS.gfcj

Page 12 of 21

Printed Date: 29/07/2014


Job: CLINICA CHILPANCINGO GUERRERO - IMSS
Mark: VE-05

Model: GB-071-6
Belt Drive Centrifugal Roof Exhaust Fan
Standard Construction Features:
- Aluminum housing - Backward inclined aluminum wheel - Curb cap with
prepunched mounting holes - Motor and drives isolated on shock mounts Birdscreen - Ball bearing motors - Adjustable motor pulley - Adjustable motor
plate - Fan shaft mounted in ball bearing pillow blocks - Bearings meet or exceed
temperature rating of fan - Static resistant belts - Corrosion resistant fasteners Sizes 141 and larger have internal Lifting lugs

Options & Accessories:


Switch, NEMA-1, Toggle, Junction Box Mounted & Wired
Unit Warranty: 1 Yr (Standard)

CAPS 4.15.1146

C:\Users\tcaballero\Desktop\CLINICA CHILPANCINGO GUERRERO - IMSS.gfcj

Page 13 of 21

Printed Date: 29/07/2014


Job: CLINICA CHILPANCINGO GUERRERO - IMSS
Mark: VE-06
24.38

Model: GB-091-4
Belt Drive Centrifugal Roof Exhaust Fan

23.75

Dimensional
Quantity

Weight w/o Acc's (lb)

56

Weight w/ Acc's (lb)

58

Max T Motor Frame Size


Roof Opening (in.)

4.38

56

19

14.5 x 14.5

1.75

Reference assembly view drawings for actual


dimensions with mounted accessories
*Overall height may be greater depending on motor

Performance
Requested Volume (CFM)

640

Actual Volume (CFM)

640

External SP (in. wg)

0.25

Total SP (in. wg)

0.25

Fan RPM

1123

Operating Power (hp)

0.08

Elevation (ft)

4,111

Airstream Temp.(F)

70

Air Density (ft3)

0.064

Drive Loss (%)

27.7

Tip Speed (ft/min)

3,291

Static Eff. (%)

42

Motor
Motor Mounted

Yes

Size (hp)
V/C/P

1/4
115/60/1

Enclosure

ODP

Motor RPM

1725

Windings
NEC FLA* (Amps)

1
5.8

Notes:

Sound Power by Octave Band


Sound
Data
Inlet

62.5

125

250

500

70

71

70

62

CAPS 4.15.1146

1000 2000 4000 8000 LwA


57

55

49

43

66

dBA Sones
54

7.2

All dimensions shown are in units of in.


*FLA - based on tables 150 or 148 of National Electrical
Code 2002. Actual motor FLA may vary, for sizing thermal
overload, consult factory.
LwA - A weighted sound power level, based on ANSI S1.4
dBA - A weighted sound pressure level, based on 11.5 dB
attenuation per Octave band at 5 ft - dBA levels are not
licensed by AMCA International
Sones - calculated using AMCA 301 at 5 ft

C:\Users\tcaballero\Desktop\CLINICA CHILPANCINGO GUERRERO - IMSS.gfcj

Page 14 of 21

Printed Date: 29/07/2014


Job: CLINICA CHILPANCINGO GUERRERO - IMSS
Mark: VE-06

Model: GB-091-4
Belt Drive Centrifugal Roof Exhaust Fan
Standard Construction Features:
- Aluminum housing - Backward inclined aluminum wheel - Curb cap with
prepunched mounting holes - Motor and drives isolated on shock mounts Birdscreen - Ball bearing motors - Adjustable motor pulley - Adjustable motor
plate - Fan shaft mounted in ball bearing pillow blocks - Bearings meet or exceed
temperature rating of fan - Static resistant belts - Corrosion resistant fasteners Sizes 141 and larger have internal Lifting lugs

Options & Accessories:


High Efficient Motor - meets Greenheck High Efficiency Table
Switch, NEMA-1, Toggle, Junction Box Mounted & Wired
Unit Warranty: 1 Yr (Standard)

CAPS 4.15.1146

C:\Users\tcaballero\Desktop\CLINICA CHILPANCINGO GUERRERO - IMSS.gfcj

Page 15 of 21

Printed Date: 29/07/2014


Job: CLINICA CHILPANCINGO GUERRERO - IMSS
Mark: VE-07
24.38

Model: GB-091-4
Belt Drive Centrifugal Roof Exhaust Fan

23.75

Dimensional
Quantity

Weight w/o Acc's (lb)

56

Weight w/ Acc's (lb)

58

Max T Motor Frame Size


Roof Opening (in.)

4.38

56

19

14.5 x 14.5

1.75

Reference assembly view drawings for actual


dimensions with mounted accessories
*Overall height may be greater depending on motor

Performance
Requested Volume (CFM)

480

Actual Volume (CFM)

480

External SP (in. wg)

0.2

Total SP (in. wg)

0.2

Fan RPM

913

Operating Power (hp)

0.06

Elevation (ft)

4,111

Airstream Temp.(F)

70

Air Density (ft3)

0.064

Drive Loss (%)

41.9

Tip Speed (ft/min)

2,673

Static Eff. (%)

46

Motor
Motor Mounted

Yes

Size (hp)
V/C/P

1/4
115/60/1

Enclosure

ODP

Motor RPM

1725

Windings
NEC FLA* (Amps)

1
5.8

Notes:

Sound Power by Octave Band


Sound
Data
Inlet

62.5

125

250

500

68

66

63

57

CAPS 4.15.1146

1000 2000 4000 8000 LwA


52

49

44

41

60

dBA Sones
48

5.0

All dimensions shown are in units of in.


*FLA - based on tables 150 or 148 of National Electrical
Code 2002. Actual motor FLA may vary, for sizing thermal
overload, consult factory.
LwA - A weighted sound power level, based on ANSI S1.4
dBA - A weighted sound pressure level, based on 11.5 dB
attenuation per Octave band at 5 ft - dBA levels are not
licensed by AMCA International
Sones - calculated using AMCA 301 at 5 ft

C:\Users\tcaballero\Desktop\CLINICA CHILPANCINGO GUERRERO - IMSS.gfcj

Page 16 of 21

Printed Date: 29/07/2014


Job: CLINICA CHILPANCINGO GUERRERO - IMSS
Mark: VE-07

Model: GB-091-4
Belt Drive Centrifugal Roof Exhaust Fan
Standard Construction Features:
- Aluminum housing - Backward inclined aluminum wheel - Curb cap with
prepunched mounting holes - Motor and drives isolated on shock mounts Birdscreen - Ball bearing motors - Adjustable motor pulley - Adjustable motor
plate - Fan shaft mounted in ball bearing pillow blocks - Bearings meet or exceed
temperature rating of fan - Static resistant belts - Corrosion resistant fasteners Sizes 141 and larger have internal Lifting lugs

Options & Accessories:


High Efficient Motor - meets Greenheck High Efficiency Table
Switch, NEMA-1, Toggle, Junction Box Mounted & Wired
Unit Warranty: 1 Yr (Standard)

CAPS 4.15.1146

C:\Users\tcaballero\Desktop\CLINICA CHILPANCINGO GUERRERO - IMSS.gfcj

Page 17 of 21

Printed Date: 29/07/2014


Job: CLINICA CHILPANCINGO GUERRERO - IMSS
Mark: VE-08
24.38

Model: GB-091-4
Belt Drive Centrifugal Roof Exhaust Fan

23.75

Dimensional
Quantity

Weight w/o Acc's (lb)

56

Weight w/ Acc's (lb)

58

Max T Motor Frame Size


Roof Opening (in.)

4.38

56

19

14.5 x 14.5

1.75

Reference assembly view drawings for actual


dimensions with mounted accessories
*Overall height may be greater depending on motor

Performance
Requested Volume (CFM)

1,050

Actual Volume (CFM)

1,050

External SP (in. wg)

0.36

Total SP (in. wg)

0.36

Fan RPM

1651

Operating Power (hp)

0.21

Elevation (ft)

4,111

Airstream Temp.(F)

70

Air Density (ft3)

0.064

Drive Loss (%)

13.6

Tip Speed (ft/min)

4,836

Static Eff. (%)

32

Motor
Motor Mounted

Yes

Size (hp)
V/C/P

1/4
115/60/1

Enclosure

ODP

Motor RPM

1725

Windings
NEC FLA* (Amps)

1
5.8

Notes:

Sound Power by Octave Band


Sound
Data
Inlet

62.5

125

250

500

74

78

78

70

CAPS 4.15.1146

1000 2000 4000 8000 LwA


66

66

61

54

74

dBA Sones
63

12.2

All dimensions shown are in units of in.


*FLA - based on tables 150 or 148 of National Electrical
Code 2002. Actual motor FLA may vary, for sizing thermal
overload, consult factory.
LwA - A weighted sound power level, based on ANSI S1.4
dBA - A weighted sound pressure level, based on 11.5 dB
attenuation per Octave band at 5 ft - dBA levels are not
licensed by AMCA International
Sones - calculated using AMCA 301 at 5 ft

C:\Users\tcaballero\Desktop\CLINICA CHILPANCINGO GUERRERO - IMSS.gfcj

Page 18 of 21

Printed Date: 29/07/2014


Job: CLINICA CHILPANCINGO GUERRERO - IMSS
Mark: VE-08

Model: GB-091-4
Belt Drive Centrifugal Roof Exhaust Fan
Standard Construction Features:
- Aluminum housing - Backward inclined aluminum wheel - Curb cap with
prepunched mounting holes - Motor and drives isolated on shock mounts Birdscreen - Ball bearing motors - Adjustable motor pulley - Adjustable motor
plate - Fan shaft mounted in ball bearing pillow blocks - Bearings meet or exceed
temperature rating of fan - Static resistant belts - Corrosion resistant fasteners Sizes 141 and larger have internal Lifting lugs

Options & Accessories:


High Efficient Motor - meets Greenheck High Efficiency Table
Switch, NEMA-1, Toggle, Junction Box Mounted & Wired
Unit Warranty: 1 Yr (Standard)

CAPS 4.15.1146

C:\Users\tcaballero\Desktop\CLINICA CHILPANCINGO GUERRERO - IMSS.gfcj

Page 19 of 21

Printed Date: 29/07/2014


Job: CLINICA CHILPANCINGO GUERRERO - IMSS
Mark: VE-09
24.38

Model: GB-081-6
Belt Drive Centrifugal Roof Exhaust Fan

23.75

Dimensional
Quantity

Weight w/o Acc's (lb)

55

Weight w/ Acc's (lb)

57

Max T Motor Frame Size


Roof Opening (in.)

4.38

56

19

14.5 x 14.5

1.75

Reference assembly view drawings for actual


dimensions with mounted accessories
*Overall height may be greater depending on motor

Performance
Requested Volume (CFM)

180

Actual Volume (CFM)

180

External SP (in. wg)

0.2

Total SP (in. wg)

0.2

Fan RPM

767

Operating Power (hp)

0.03

Elevation (ft)

4,111

Airstream Temp.(F)

70

Air Density (ft3)

0.064

Drive Loss (%)

50.0

Tip Speed (ft/min)

2,245

Static Eff. (%)

43

Motor
Motor Mounted

Yes

Size (hp)
V/C/P

1/6
115/60/1

Enclosure

ODP

Motor RPM

1725

Windings
NEC FLA* (Amps)

1
4.4

Notes:

Sound Power by Octave Band


Sound
Data
Inlet

62.5

125

250

500

61

61

56

50

CAPS 4.15.1146

1000 2000 4000 8000 LwA


46

40

34

32

53

dBA Sones
41

2.9

All dimensions shown are in units of in.


*FLA - based on tables 150 or 148 of National Electrical
Code 2002. Actual motor FLA may vary, for sizing thermal
overload, consult factory.
LwA - A weighted sound power level, based on ANSI S1.4
dBA - A weighted sound pressure level, based on 11.5 dB
attenuation per Octave band at 5 ft - dBA levels are not
licensed by AMCA International
Sones - calculated using AMCA 301 at 5 ft

C:\Users\tcaballero\Desktop\CLINICA CHILPANCINGO GUERRERO - IMSS.gfcj

Page 20 of 21

Printed Date: 29/07/2014


Job: CLINICA CHILPANCINGO GUERRERO - IMSS
Mark: VE-09

Model: GB-081-6
Belt Drive Centrifugal Roof Exhaust Fan
Standard Construction Features:
- Aluminum housing - Backward inclined aluminum wheel - Curb cap with
prepunched mounting holes - Motor and drives isolated on shock mounts Birdscreen - Ball bearing motors - Adjustable motor pulley - Adjustable motor
plate - Fan shaft mounted in ball bearing pillow blocks - Bearings meet or exceed
temperature rating of fan - Static resistant belts - Corrosion resistant fasteners Sizes 141 and larger have internal Lifting lugs

Options & Accessories:


Switch, NEMA-1, Toggle, Junction Box Mounted & Wired
Unit Warranty: 1 Yr (Standard)

CAPS 4.15.1146

C:\Users\tcaballero\Desktop\CLINICA CHILPANCINGO GUERRERO - IMSS.gfcj

Page 21 of 21