SINGLE-MODE OPTICAL FIBRE

CABLE

Version 1.0
Issued March 2011

Owner:

Telecommunications Network Manager, Communications & Control Systems

Approved
by:

P. Kerrigan
Telecommunications Network
Manager
Communications & Control
Systems
Asset Operations

Authorised
by:

J. Byron
Chief Engineer,
Telecommunications
Chief Engineer Division

Disclaimer
This document was prepared for use on the RailCorp Network only.
RailCorp makes no warranties, express or implied, that compliance with the contents of this document shall be
sufficient to ensure safe systems or work or operation. It is the document users sole responsibility to ensure that the
copy of the document it is viewing is the current version of the document as in use by RailCorp.
RailCorp accepts no liability whatsoever in relation to the use of this document by any party, and RailCorp excludes
any liability which arises in any manner by the use of this document.
Copyright
The information in this document is protected by Copyright and no part of this document may be reproduced, altered,
stored or transmitted by any person without the prior consent of RailCorp.

UNCONTROLLED WHEN PRINTED

Page 1 of 17

Engineering Specification

Engineering Specification
Telecommunications

RailCorp Engineering Specification Telecommunications


Single-Mode Optical Fibre Cable

SPM 0677

Document control
Revision
1.0

Date
March
2011

Author
R. Faulks

Reviewers
P. Kerrigan
E. Rediblado

Summary of change
First Issue

Summary of changes from previous version


Summary of change

RailCorp
Issued March 2011

Section

UNCONTROLLED WHEN PRINTED

Page 2 of 17
Version 1.0

RailCorp Engineering Specification Telecommunications


Single-Mode Optical Fibre Cable

SPM 0677

Contents
1

PURPOSE........................................................................................................................................ 4

SCOPE & APPLICATION................................................................................................................ 4

REFERENCE DOCUMENTS........................................................................................................... 4

3.1
3.2
3.3

AUSTRALIAN STANDARDS ............................................................................................................ 4

INTERNATIONAL STANDARDS ........................................................................................................ 5

OTHER DOCUMENTS .................................................................................................................... 5

ABBREVIATIONS AND DEFINITIONS........................................................................................... 5

GENERAL REQUIREMENTS.......................................................................................................... 6

5.1
5.2
5.3
5.4
5.5
5.6

CABLE CONSTRUCTION ................................................................................................................ 6

STOCK STANDARD CABLE ............................................................................................................ 6

OPTICAL CHARACTERISTICS ......................................................................................................... 7

CABLE ELEMENT REQUIREMENTS ................................................................................................. 8

MECHANICAL AND ENVIRONMENTAL............................................................................................ 11

CABLE MARKING ....................................................................................................................... 13

PACKAGING AND DELIVERY ..................................................................................................... 13

DOCUMENTATION ....................................................................................................................... 14

REGULATORY & QUALITY ASSURANCE.................................................................................. 15

WARRANTY .................................................................................................................................. 16

10

INFORMATION TO BE SUPPLIED ........................................................................................... 16

APPENDIX 1 SAMPLE PRODUCT DATA SHEET ........................................................................... 17

RailCorp
Issued March 2011

UNCONTROLLED WHEN PRINTED

Page 3 of 17

Version 1.0

RailCorp Engineering Specification Telecommunications


Single-Mode Optical Fibre Cable

SPM 0677

Purpose
The purpose of this document is to specify the technical requirements for Single Mode
Optical Fibre (SMOF) cable, hereafter referred to as the Cable.
The Cable is required for carriage of telecommunications services by way of optical
transmissions over distances ranging from a few metres to over 100 kilometres. The
cable is to be suitable for operation in the general rail environment including areas
electrified with 1500V DC or High Voltage AC and locations where fire and life safety are
an issue.

Scope & Application


The scope of this document includes SMOF Cable with construction suited to the
following installations:

General Installation - Cable suitable for general installation in the rail


environment by way of direct burial, hauling into underground ducts, hauling into
above ground steel troughing and laying in ground level concrete troughing.

Fire Safe - Cable for installation in underground stations or other underground


facilities and tunnels where fire and safety are a primary concern.

Blown Cable - Cable for installation by way of air/gas blowing through


continuous conduits.

The scope of this specification does not include the following optical fibre cables:

Multi Mode Optical Fibre

Aerial Cable - (Aerial SMOF may be included in a later revision of this


specification or a separate specification in future.)

Fire Resistant - (Fire Resistant SMOF may be included in a later revision of this
specification or a separate specification in future.)

Internal use building horizontal and riser cable

Pre-terminated SMOF tie cables - (These are the subject of a separate


specification).

This specification is applicable to both procurement and type approval assessment of the
Cable

Reference Documents

3.1

Australian Standards
AS 2706

Numerical values Rounding and interpretation of limiting values

AS 1049

Telecommunications cables Insulation, sheath and jacket

AS/NZS
1660.5.2

Test methods for electric cables, cords and conductors - Fire tests Measurement of smoke density of cables burning under defined
conditions

AS/NZS
1660.5.3

Test methods for electric cables, cords and conductors - Fire tests Determination of the amount of halogen acid gas evolved during the
combustion of polymeric materials taken from cables

AS/NZS
1660.5.4

Test methods for electric cables, cords and conductors - Fire tests Determination of degree of acidity of gases evolved during the
combustion of materials taken from electric cables by measuring pH and
conductivity

RailCorp
Issued March 2011

UNCONTROLLED WHEN PRINTED

Page 4 of 17
Version 1.0

RailCorp Engineering Specification Telecommunications


Single-Mode Optical Fibre Cable

3.2

AS/NZS 3080

Telecommunications installations Generic cabling for commercial


premises

AS/NZS ISO
9001

Quality management systems - Requirements

AS/ACIF
S008

Requirements for customer cabling products

International Standards

3.2.1

IEC Publications
IEC 60793-1-1

Optical fibres Part 1: Measurement methods and test procedures

IEC 60793-2

Optical fibres Part 2: Product specifications - General

IEC 60794-1-1

Optical fibre cables Generic specification

IEC 60794-1-2

Optical fibre cables Generic specification - Basic optical cable test


procedures

3.2.2

ITU Recommendations
G.652

Characteristics of a single-mode optical fibre and cable

G.655

Characteristics of a non-zero dispersion shifted single-mode optical fibre


and cable

3.2.3

3.3

SPM 0677

EIA Standards
ANSI/EIA
359-A

Standard Colours for Colour Identification and Coding

ANSI/TIA/EIA
598-C

Optical Fibre Cable Colour Coding

Other Documents
Australian Communications and Media Authority - Telecommunications Labelling and
Compliance
European Union Directive 2002/95/EC Restriction of the use of Hazardous Substances in
Electrical and Electronic Equipment (RoHS)
The Munsell Colour Charts

Abbreviations and Definitions


SMOF

Single Mode Optical Fibre

MMOF

Multi Mode Optical Fibre

The Cable

Single Mode Optical Fibre Cable that is the subject of this Specification

RoHS

Indicates The Cable meets European Union directive 2002/95/EC


Restriction on the use of Hazardous Substances

RailCorp
Issued March 2011

UNCONTROLLED WHEN PRINTED

Page 5 of 17
Version 1.0

RailCorp Engineering Specification Telecommunications


Single-Mode Optical Fibre Cable

General Requirements

5.1

Cable Construction

5.1.1

SPM 0677

The Cable shall incorporate an inner core comprising an inner cable sheath containing
the following elements:
a) A central strength member.
b) The specified quantity of SMOF cores which shall generally be Single Mode Low
Water Peak fibres meeting ITU-T Recommendation G652.D.
c) The specified quantity of additional SMOF Non-Zero Dispersion Shifted fibres
meeting ITU-T Recommendation G655.
d) Loose tubes containing either 6 or 12 fibres per tube.
e) Solid fillers replacing loose tubes where there are less than the full cable capacity
of fibres is required.
f)

Core Blocking. (to prevent the migration of water along the cable core)

g) A black polyethylene inner sheath.


5.1.2

The Cable inner core may contain other wrapping or strengthening elements designed
to improve cable performance subject to full details being supplied for RailCorp
engineering assessment and acceptance.

5.1.3

General Installation cable shall incorporate the following outer sheath elements:

a) An insect resistant jacket

b) A rodent resistant layer

c) A polyethylene outer sheath

5.1.4

Fire Safe cable shall incorporate the following outer sheath elements:

a) An insect resistant jacket

b) A rodent resistant layer

c) A Low Smoke, Fire Retardant, Zero Halogen outer sheath

5.1.5

Blown cable shall incorporate the following outer sheath elements:

a) An insect resistant jacket as the outer sheath

5.1.6

The Cable shall not contain any metallic or electrically conductive elements.

5.1.7

The Cable shall not contain any multi mode optical fibre.

5.2

Stock Standard Cable

5.2.1

RailCorp
Issued March 2011

The Cable shall be offered and supplied in stock standard cable sizes and
configurations as follows:

UNCONTROLLED WHEN PRINTED

Page 6 of 17
Version 1.0

RailCorp Engineering Specification Telecommunications


Single-Mode Optical Fibre Cable

Item

5.2.2

5.3

SPM 0677

Description (SMOF is G.652.D unless specified otherwise)

a)

12 SMOF General Installation

b)

12 SMOF Fire Safe

c)

24 SMOF General Installation

d)

24 SMOF Fire Safe

e)

48 SMOF General Installation

f)

48 SMOF Fire Safe

g)

72 SMOF 12 G655 + 60 G.652.D General Installation

h)

72 SMOF 12 G655 + 60 G.652.D Fire Safe

i)

72 SMOF 12 G655 + 60 G.652.D Blown

j)

96 SMOF General Installation

k)

96 SMOF Fire Safe

l)

96 SMOF Blown

m)

96 SMOF 24 G655 + 72 G.652.D General Installation

n)

96 SMOF 24 G655 + 72 G.652.D Fire Safe

o)

96 SMOF 24 G655 + 72 G.652.D Blown

p)

144 SMOF General Installation

q)

144 SMOF Fire Safe

r)

240 SMOF 24 G655 + 216 G.652.D Fire Safe

Cable sizes and configurations other than stock standard may be used only where
required to meet a particular engineering design approved by the owner of this
specification or delegated approval authority.

Optical Characteristics

5.3.1

Fibres within the cable shall meet the optical characteristic requirements tabled below:
TABLE A
OPTICAL FIBRE REQUIREMENTS
Fibre Type and Characteristics
Parameter

A1

Standards / references

Single Mode

Single Mode

Low Water Peak (LWP)

Non-Zero Dispersion
Shifted (NZDS)

AS/NZS 3080 OS1

ITU-T Rec. G655

ITU-T Rec. G652.D

IEC 60793-2 type B1.4

IEC 60793-2 type B1.3


A3

Mode Field Diameter

A4

Cladding Diameter

RailCorp
Issued March 2011

9.2 0.5 m at 1310nm

Nom 8.4 ~ 9.6 0.6m

125 0.7 m

125 0.7 m

UNCONTROLLED WHEN PRINTED

Page 7 of 17
Version 1.0

RailCorp Engineering Specification Telecommunications


Single-Mode Optical Fibre Cable

SPM 0677

TABLE A
OPTICAL FIBRE REQUIREMENTS
Fibre Type and Characteristics
Parameter

A5

Core/Cladding Concentricity
Error

A6

Cladding Non-circularity

A7

Cut-off wavelength of cabled


fibre

A9

Bending performance

Single Mode

Single Mode

Low Water Peak (LWP)

Non-Zero Dispersion
Shifted (NZDS)

0.6 m

0.6 m

1%

1%

1260 nm

1450 nm

100 turns, 60 mm diameter

100 turns, 60 mm diameter

0.10 dB at 1625nm

0.10 dB at 1625nm

0.69 GPa (100kpsi)

0.69 GPa (100kpsi)

A10

Proof Stress

A11

Zero Chromatic Dispersion


Wavelength

1300nm o 1324nm

Supplier shall advise

A12

Maximum Zero dispersion


slope

0.092 ps/mn.km

Supplier shall advise

A13

Coating Strip Force

1.3 ~ 8.9 N

1.3 ~ 8.9 N

A14

Attenuation coefficient of
Fibre in Finished Cable

< 0.35 dB/km @ 1310nm

< 0.23 dB/km @ 1550nm

< 0.35 dB/km @ 1383nm

< 0.25 dB/km @ 1625nm

< 0.22 dB/km @ 1550nm


A15

Maximum Localised
Attenuation Discontinuity

A16

Polarization Mode Dispersion


(PMD)

A17

Refractive index for (OTDR


calibration)

5.4

< 0.05 dB @ 1310nm

< 0.05 dB @ 1310nm

< 0.05 dB @ 1550nm

< 0.05 dB @ 1550nm

0.2 ps/km, q=0.01%,


m=20

0.2 ps/km, q=0.01%,


m=20

Supplier shall advise

Supplier shall advise

Cable Element Requirements

5.4.1

RailCorp
Issued March 2011

Elements within the cable shall meet the physical characteristic requirements tabled
below:

UNCONTROLLED WHEN PRINTED

Page 8 of 17
Version 1.0

RailCorp Engineering Specification Telecommunications


Single-Mode Optical Fibre Cable

SPM 0677

TABLE B
CABLE ELEMENT PHYSICAL REQUIREMENTS
Parameter
B1

Fibres

Requirement
Fibres shall be:
a) 250 um, uv-cured acrylate coated, high purity silicon dioxide glass with
suitably doped core and to the optical characteristics in Table A.
b) Individually and indelibly coloured in accordance with EIA/TIA-598-C
Optical Fibre Cable Colour Coding and in the sequence of Blue, Orange,
Green, Brown, Grey, White, Red, Black, Yellow, Violet, Pink and Aqua.
c) Suitable for fusion splicing
d) Continuous, unjointed and un-spliced through the entire length of any
cable drum supplied

B3

Central
Strength
Member

The central strength member shall be:


a) Made of fibreglass-reinforced plastic (FRP)
b) Sheathed where appropriate to increase the diameter to accommodate
the number of tubes required.

B4

Loose Tubes

The loose tubes shall be:


a) Made of polybutylene terephthalate (PBT) or equivalent material
b) Individually and indelibly coloured in accordance with EIA/TIA-598-C
Optical Fibre Cable Colour Coding and in the sequence of Blue,
Orange, Green, Brown, Grey, White, Red, Black, Yellow, Violet, Pink &
Aqua
c) Contain 6 fibres for cables containing up to 48 fibres
d) Contain 12 fibres for cables containing more than 48 fibres
e) Contain one grade of fibre only in each tube where different grades of
single-mode fibre are incorporated into a cable
f)

Have a sequence of priority in populating the tubes with G655 in the first
tube(s) where different grades of single-mode fibre are incorporated into
a cable

g) S-Z stranded (oscillated) around the central strength member


B5

Tube Filling
Compound

The buffer tube shall be fully water-blocked with thixotropic jelly or equivalent
material, having a drop point of 80C.

B8

Fillers

Fillers shall be:


a) Used where less than the full cables capacity of fibres is required
b) Solid and of the same diameter as the tubes
c) Placed in sequence after the last tube and before first.

B9

Core Blocking

Core blocking shall:


a) Fully water-block the inner cable core
b) Preferably use dry block technology with such materials as tapes, yarns
or equivalent, loaded with super absorbent polymers.

RailCorp
Issued March 2011

UNCONTROLLED WHEN PRINTED

Page 9 of 17
Version 1.0

RailCorp Engineering Specification Telecommunications


Single-Mode Optical Fibre Cable

SPM 0677

TABLE B
CABLE ELEMENT PHYSICAL REQUIREMENTS
Parameter

Requirement

B10

Wrapping and
or
strengthening
elements

Any additional wrapping and or strengthening elements where used shall not
bond to any inner core components.

B12

Inner Cable
Sheath

The Inner Cable Sheath shall:


a) Be made of black polyethylene suitable for external exposed applications
b) Be free from holes, splits, blisters or other imperfections
c) Have appropriate thickness to meet all other requirements of this
specification

B13

B14

Insect Resistant
Jacket

Rodent
Resistant
Layer

The Insect Resistant Jacket shall:


a)

Be Pa 12 or Pa 11

b)

Be applied over the inner cable sheath

c)

Be light blue in colour

d)

Be free from holes, splits, blisters or other imperfections.

e)

Not buckle under curvature to the minimum cable bending radius

f)

Have minimum thickness of 0.3mm or be 0.2mm if bonded to the inner cable


sheath.

The Rodent Resistant Layer shall be:


a) Made of glass yarns, GRP or similar material designed to provide
protection of the inner core from chewing by rodents
b) Applied over the insect resistant jacket
c) Used in general installation and fire safe cable
d) Not used in blown cable

B15

Polyethylene
Outer Sheath

The Polyethylene Outer Sheath shall be:


a) Made of polyethylene of appropriate thickness to meet the requirements
of this specification
b) Meet the requirements of AS 1049 as being suitable for external exposed
applications
c) Sufficiently high in density to allow the cable glide smoothly through ducts
and across other cables while not producing excessive drag
d)

RailCorp
Issued March 2011

Light blue in colour

UNCONTROLLED WHEN PRINTED

Page 10 of 17
Version 1.0

RailCorp Engineering Specification Telecommunications


Single-Mode Optical Fibre Cable

SPM 0677

TABLE B
CABLE ELEMENT PHYSICAL REQUIREMENTS
Parameter
B16

Low Smoke,
Zero Halogen
Outer Sheath

Requirement
The Low Smoke Zero Halogen Outer Sheath shall be:
a) Made of materials suitable for use in underground locations where fire
and life safety are an issue
b) Of appropriate thickness to meet the requirements of this specification
c) Meet the requirements of AS 1049 as being suitable for external protected
applications
d) Sufficiently high in density to allow the cable glide smoothly through ducts
and across other cables while not producing excessive drag
e) Light blue and in colour.
The Low Smoke Zero Halogen Sheath shall meet the following standards
requirements:
a) Halogen content may not exceed 0.5% or 5 mg/g tested in accordance
with AS/NZS 1660.5.3
b) The limit values of acidity of combustion gases are 4.3 for pH and 10 S
for conductivity tested in accordance with AS/NZS 1660.5.4
c) When tested using a 27m volume smoke chamber in accordance with
AS/NZS 1660.5.2 the smoke emission must result in not less than 60%
light transmittance.

5.5

Mechanical and Environmental

5.5.1

The Cable shall generally be designed to meet the harsh environmental conditions that
are expected in the heavy railway industry with a service life of at least 40 years when
correctly installed and maintained to supplier recommendations and practices.

5.5.2

Elements within the cable shall meet the Mechanical and Environmental characteristic
requirements tabled below:

RailCorp
Issued March 2011

UNCONTROLLED WHEN PRINTED

Page 11 of 17
Version 1.0

RailCorp Engineering Specification Telecommunications


Single-Mode Optical Fibre Cable

SPM 0677

TABLE C
MECHANICAL AND ENVIRONMENTAL REQUIREMENTS
Parameter

Test Requirements
Sample:

50m cable

C1

Tensile Strength
IEC 60794-1-2
Method E1

C2

Crush Resistance
IEC 60794-1-2
Method E3

Conditions: 2000N/100mm,
for 10 mins

Impact Resistance
IEC 60794-1-2
Method E4

Conditions: 1.5kg, 1m height,


12.5 mm anvil radius,
3 impacts ~ 100mm
apart

Torsion
IEC 60794-1-2
Method E7

Conditions: 1m twisted length,


360o, 10kg load,
10 cycles

C3

C4

C5

Cable Bend
IEC 60794-1-2
Method E11A

conditions: 2000N held at peak


load for 10min

Conditions: Mandrel OD 19 x
cable OD, one turn

C6

Sample:

C7

Temperature
Cycling
IEC 60794-1-2
Method F1

RailCorp
Issued March 2011

A representative sample of fibres to


be monitored, loss variation shall not
exceed 0.1dB in any fibre tested, and

A representative sample of fibres to


be monitored, loss variation shall not
exceed 0.1dB in any fibre tested, and
No visible damage to any fibre coating
A representative sample of fibres to
be monitored, loss variation shall not
exceed 0.1dB in any fibre tested, and
No mechanical damage to cable
A representative sample of fibres to
be monitored, loss variation shall not
exceed 0.1dB in any fibre tested, and
No buckling of cable sheath or jackets

Sample:

Representative
Samples

A representative sample of fibres to


be monitored, loss variation shall not
exceed 0.1dB in any fibre tested

No visible damage to any fibre coating

Water Penetration
IEC 60794-1-2
Method F5B

C8

Acceptance Criteria

3m

Conditions: 1m head of water,


24hrs
> 500m,

Conditions: 2 cycles
ambient to -20oC to
+70oC to ambient.

No water shall be detected at the


unsealed end of the sample.

A representative sample of fibres to


be monitored, loss variation shall not
exceed 0.1dB in any fibre tested.

Representative samples of fibres


to be monitored

a) All fibres shall be monitored

a) Cables up to 12 fibres

b) A minimum of 12 fibres distributed


evenly throughout the tubes shall
be monitored, and if more than 6
tubes then 2 fibres from each tube
shall be monitored.

b) Cables with more than 12


fibres

UNCONTROLLED WHEN PRINTED

Page 12 of 17
Version 1.0

RailCorp Engineering Specification Telecommunications


Single-Mode Optical Fibre Cable

5.6

SPM 0677

Cable Marking

5.6.1

All marking and labelling on the cable, cable drum and any other packaging shall be in
English language only.

5.6.2

The outer sheath of the cable shall be indelibly marked with a sheath message as
follows:
a) In black print of minimum 3mm print height
b) Printed at every metre length of the cable
c) Not include markings of customers other than RailCorp

5.6.3

The sheath message shall be in the following format and description:


RailCorp <product code> <description> <MMM YYYY> CN<cable number> ROHS
<mmmm>M

Format Item

Description

<product code>

Supplier to provide details

<description>

Cable description e.g. 48 SMOF - GENERAL INST.

<MMM YYYY>

Date of manufacture: month & year e.g. SEP 2011

<cable number>

A unique cable identification number provided by the cable


manufacture

<mmmm> M

Sequential length mark in meters starting at zero (0000) at the inner


end of the drum. e.g. 0125M

Packaging and Delivery


6.1.1

The Cable shall be delivered free of joints in lengths as ordered by RailCorp with both
ends sealed with heat shrink end caps.

6.1.2

Where the Cable is delivered in lengths less than that ordered, RailCorp reserves the
right to refuse delivery and/or payment for such lengths. All costs for shipping such
lengths shall be at the suppliers expense including any scrapping or return shipping
costs.

6.1.3

Where a drum contains a length in excess of the length ordered by RailCorp, RailCorp
shall only pay length that was ordered.

6.1.4

The Cable shall be delivered on drums with:


a) Durable robust construction including reinforcing battens designed to protect the
Cable from damage during storage, shipping, handling, reeling and unreeling
b) Bark free timber where constructed from timber
c) Fasteners such as nails, screws and staples positioned so that they cannot
damage the cables even if improperly fixed
d) The spindle hole greater than 75mm

RailCorp
Issued March 2011

UNCONTROLLED WHEN PRINTED

Page 13 of 17
Version 1.0

RailCorp Engineering Specification Telecommunications


Single-Mode Optical Fibre Cable

SPM 0677

e) A protective housing providing access at least 2m of the inner cable end for
testing purposes
6.1.5

Cable drums shall be indelibly marked and labelled by stencilling on both drum flanges
as follows:
a) Clearly laid out for reading in a store yard or field installation environment
b) Not include any user company or organisation name other than RailCorp

6.1.6

Cable drum labelling shall include the following detail:


a) The word RailCorp
b) Manufacturers name or logo
c) Manufacturers product code
d) ACMA A-Tick compliance label
e) Month and year of manufacture, in the format for example of SEP 2011
f)

Length of the Cable in metres

g) Cable description including fibre count, fibre specification and cable construction
type
h) Gross weight of the cable, drum and any other packing
i)

How to access the MSDS

Documentation
7.1.1

All supplier documentation shall be in English language

7.1.2

The supplier shall provide documentation as follows:

a) Cable Product Data sheet(s) for each cable configuration included with each

request for quotation and/or tender


b) Cable test sheet(s) delivered with each drum of cable
c) Material Safety Data Sheet to be made available on request and freely available
by user access to the supplier internet site

7.1.3

The Cable Product Data sheet(s) shall include the following detail as a minimum:

a) Cable description

b) Cable cross-section showing all the various physical cable elements with

diameters and radial thickness as appropriate:


c) The materials used for construction of each cable element
d) Cable mass in kg per 1000m
e) Outside diameter and tolerance in mm
f)

Minimum bend radius at no load and full load in mm

g) Maximum allowable tensile strength during installation in kN


h) Crush resistance - short term and long term in kN/100mm
i)

RailCorp
Issued March 2011

Operating temperature range in C

UNCONTROLLED WHEN PRINTED

Page 14 of 17
Version 1.0

RailCorp Engineering Specification Telecommunications


Single-Mode Optical Fibre Cable

SPM 0677

j) Refractive index of the cabled fibre for each type of fibre used (for OTDR
calibration)
7.1.4

The Cable Product Data sheet(s) shall have data clearly laid out in a manner similar to
the sample shown in Appendix 1.

7.1.5

The Cable Test Sheet(s) shall include documentation as follows:


a) Product code / name
b) Cable description
c) Cable identification number as printed on the cables outer sheath
d) Drum and/or batch numbers
e) Tests performed
f)

Test results including dates tested and tester sign off. These documented results
shall include as a minimum:

Attenuation of each fibre at the wavelength in table A section A14.

Detail of any localised attenuation discontinuity if applicable.

Results of any batch mechanical and environmental test if applicable.

Regulatory & Quality Assurance


8.1.1

The Supplier shall have a Quality Management System that is certified to ISO 9001.

8.1.2

The cable shall be produced for the Australian market and meet the requirements of
AS/ACIF S008

8.1.3

The Cable shall be current production release with extensive proven field operation
within Australia

8.1.4

Cable materials shall be non toxic and dermatologically safe and comply with the
European Union Directive 2002/95/EC on Restriction of the use of Hazardous
Substances in Electrical and Electronic Equipment (RoHS).

8.1.5

The interpretation of tolerances shall be in accordance with AS 2706

8.1.6

Prior to delivery, the cable shall be performance tested including the following
mandatory tests:
a) Water Penetration Test on each batch length of cable (refer to Table C item C6)
b) Attenuation of Fibre in Finished Cable for all fibres in each drum length of cable
(refer to Table A item A14)
c) Maximum Allowable Attenuation Discontinuity (Point Loss) for all fibres in each
drum length of cable (refer to Table A item A15)

RailCorp
Issued March 2011

UNCONTROLLED WHEN PRINTED

Page 15 of 17
Version 1.0

RailCorp Engineering Specification Telecommunications


Single-Mode Optical Fibre Cable

SPM 0677

W
arranty
9.1.1

The manufacturer of the cable shall warrant that for ten years from the date of supply
that the cable shall be free from all defects resulting from faulty design, faulty
materials, faulty manufacturing process or poor workmanship.

9.1.2

The supplier shall be responsible for:


a) all costs associated with the replacement of cable found defective within 5 years
from delivery
b) replacement of cable found defective after 5 years and within 10 years from
delivery

10

Information To Be Supplied

10.1.1

The following information shall be supplied with any Request for Tender and/or for
Type Approval.
a) A clause by clause statement of compliance with this specification
b) Cable Product Data Sheet(s)
c) ISO 9001 Quality Management System certification
d) AS/ACIF S008 product certification
e) A statement on the toxicological characteristics of the cable components including
detail on how to freely obtain the Material Safety Data Sheet

f)

RailCorp
Issued March 2011

Full details of the warranty offered and any condition that apply.

UNCONTROLLED WHEN PRINTED

Page 16 of 17
Version 1.0

Appendix 1 Sample Product Data Sheet

Supplier Name/logo
Product Number: #######

RailCorp Cable
Product Name: #############

Product description for example: Single Mode Optical Fibre cable 144 core, rodent resistant, loose
tube construction, 12 fibres per tube, Manufactured in accordance with RailCorp SPM0677 for general
installation in the rail corridor. Fibres 1 to 24 - G.655 and fibres 25 to 144 - G.652d.

Loose Tubes
Optical Fibres

Filling Gel

Central Strength Member

Core Wrapping and Tape

Dry Block Tapes

Glass Armour
PE Inner Sheath
PE Outer Sheath
Nylon Jacket
PE Filler

Component
Strength Member
PE Filler
Tubes
Inner PE Sheath
Nylon Jacket
Outer PE Sheath

Materials
Glass Reinforced Plastic
Medium Density Polyethylene (Black)
Polybutylene Terephthalate
Medium Density Polyethylene (Black)
Nylon 12 (Blue)
Medium Density Polyethylene (Blue)

Physical and mechanical properties


Cable mass in kg per 1000m
Minimum bend radius at no load
Minimum bend radius at full load
Crush resistance - short term
Crush resistance - long term
Maximum allowable tensile strength
Operating temperature range in C
Any other properties

Outside Diameter
X.Xmm
X.Xmm
X.Xmm
XX.X + X.Xmm
N/A
XX.X + X.Xmm

XXX kgs
XXXmm
XXXmm
XXXkN/100mm
XXXkN/100mm
XXXkN
-XX to XX
XXXXX

G655 - Fibres 1 - 24 (tubes 1 & 2)


Refractive index of cabled fibre: X.XXXX
G.652.D - Fibres 25 - 144 (tubes 3 & 12)
Refractive index of cabled fibre: X.XXXX

Radial Thickness
N/A

X.Xmm

X.Xmm

X.Xmm

X.Xmm

X.Xmm

Additional data + any toxicological


or other warnings.
e.g.
This cable is designed for
RailCorp for general use within
the rail corridor; it is not suitable
for underground locations or
installation by blowing down small
diameter pipes.
For the Material Safety Data Sheets
contact our office on (nn) nnnnnnnn
or website http://www.xxxxxx.com.au

Fibre and Tube Colour Sequence: Blue, Orange, Green, Brown, Grey, White, Red, Black, Yellow, Violet, Pink, Aqua.

Supplier details: Name, Address, Telephone, webpage etc.

UNCONTROLLED WHEN PRINTED

Page 17 of 17