Sei sulla pagina 1di 45

Flexi BSC Architecture and Interfaces

Flexi BSC Architecture and Interfaces


RG20 (BSS)

Soc Classification level


1
Nokia Siemens Networks

RN28193EN20GLA0

RN28193EN20GLA0

Flexi BSC Architecture and Interfaces

Objectives
After this module you should be able to:
Explain the architecture and capacity of NSN Flexi BSC Family (BSC3i 660, BSC3i 1000/2000, and

Flexi BSC)
Explain unit functions of switching unit, computer units (MCMU, BCSU and OMU) and PCU
Describe the synchronization and internal LAN within Flexi BSC
Describe Flexi BSC interfaces units: ET,SET,EET and ETIP/ETP for IP/Ethernet
Explain the other units related to mass memory storage (WDU), removable storage (MO, USB), I/O
devices (VDU, LPT), Power distribution (PDFU) and Fan units.
Explain the capacity of TRX, SS7 & LAPD signalling, packet channels, and capacity upgrade in BSC
type variants
Apply MML command to interrogate BSC hardware database
Interpret the information for when do hardware interrogation
Demonstrate to check the unit state with MML command
Interpret the capacity of AS7 plug-in unit related to SS7, LAPD channels
Interpret the capacity of PCU related to Gb interface and Abis interface for packet data channels

Soc Classification level


2
Nokia Siemens Networks

RN28193EN20GLA0

Refer to S15 Documentation:


BSC/TCSM descriptions\ Product description of BSC2i and BSCi High
Capacity Base Station Controller
BSC/TCSM descriptions \ Product description of BSC3i High Capacity
Base Station Controller
BSC/TCSM descriptions \ Product description of Flexi BSC
BSC/TCSM descriptions \ Product description of TCSM2A and
TCSM2E
BSC/TCSM descriptions \ Product description of TCSM3i High Capacity
Transcoder Multiplexer
Required equipment: One working VDU terminal for each work group.
Note:
This document consists of different BSC types and there architecture. The slides could
be selected depending on customer needs

RN28193EN20GLA0

Flexi BSC Architecture and Interfaces

RG20 (BSS) Compatibility Matrix


The standardization baseline of RG20 release is 3GPP
Release 8 meeting #41.
The compatibility of RG20 System Release for individual
network element (NE) releases are as follows:

RG20 consists of the releases:


BSC S15, MetroSite CXM8.0, UltraSite CX8.0, FlexiEDGE
EX4.0, BTSPlus BRG2.

RG20 is supported by the following NE releases:


NetAct OSS5.2 CD set 3, MSC M15, and SGSN SG8
Soc Classification level
3
Nokia Siemens Networks

RN28193EN20GLA0

The BSCi / BSC2i / TCSM2 and Talk Family BTS systems are compatible (supported) by
the RG20 (BSS) Release. Also, the new RG20 (BSS) features are not supported by the
Transcoder TCSM2 and Talk Family BTSs.

RN28193EN20GLA0

Flexi BSC Architecture and Interfaces

BSC Product Naming on S15 level


BSC = Base Station Controller, a general term for all BSC versions
General
name

Product name

Explanation

BSCi/2i

BSCi

High Capacity (upgraded) version of the first generation Nokia


DX 200 BSC (BSCE)

BSC2i

High Capacity version of the second generation Nokia DX 200


BSC2

BSC3i 660

660 TRX one cabinet configuration,


upgradeable to Flexi BSC

BSC3i
1000/2000

1000 TRX one cabinet or 2000 TRX two cabinet configuration,


upgradeable to Flexi BSC

Flexi BSC

3000 TRX one cabinet configuration (RG10)


4200 TRX one cabinet configuration (RG20)

Flexi BSC
product
family

Flexi BSC product family is a general term for all BSCs upgradeable to Flexi BSC configuration
Flexi BSC as product name is specific for the 3000/4200 TRX one cabinet product/configuration
Soc Classification level
4
Nokia Siemens Networks

RN28193EN20GLA0

RN28193EN20GLA0

Flexi BSC Architecture and Interfaces

RG20 (BSS) BSC Hardware Requirements


RG20 (BSS) BSC hardware Requirements
RG20 (BSS) Software supports Flexi BSC Family (Flexi BSC, BSC3i 1000/2000
and BSC3i 660), BSC2i, and BSCi.

Some functionality (such as ETP/ETP-A Plug-in unit for Packet Abis and A Over
IP) will be available only for Flexi BSC, BSC3i 1000/2000

The RG20 (BSS) Release sets the same mandatory minimum hardware:
Memory requirement (as per the RG10 (BSS) Release) :
Flexi BSC3 1 GB in MCMU, BCSU and OMU.
BSC3i 660 and 1000/2000: 512 MB in BCSU, 1 GB in MCMU and OMU.
BSCi and BSC2i: 512 MB in OMU, MCMU and BCSU.

Minimum Hard Disk (as per the BSS13 and RG10 (BSS) release) :
4GB in BSCi and BSC2i product and in minimum 9GB in BSC3i

Typical minimum O&M Link Capacity requirements (as per BSS13 and the
RG10 (BSS) release) :
BSC3i 2000: minimum 1024 kbit/s, recommended 2048 kbit/s
BSC3i 1000: minimum 512 kbit/s, recommended 1024 kbit/s
BSCi, BSC2i, BSC3i 660: minimum 256 kbit/s, recommended 512 kbit/s.
Soc Classification level
5
Nokia Siemens Networks

RN28193EN20GLA0

RN28193EN20GLA0

Flexi BSC Architecture and Interfaces

RG20 (BSS) TCSM Hardware Requirements


RG20 (BSS) TCSM hardware Requirements
RG20 (BSS) Software supports the TCSM3i and TCMS2.
New transcoding related Application SW in RG20 (BSS) will be supported
only by TCSM3i.

Soc Classification level


6
Nokia Siemens Networks

RN28193EN20GLA0

RN28193EN20GLA0

Flexi BSC Architecture and Interfaces

RG20 (BSS) PCU Hardware Requirements


RG20 (BSS) PCU hardware Requirements

RG20 (BSS) Software supports the PCU1 and PCU2.


PCU2 Plug-in Unit is mandatory hardware requirements for
following new RG20 (BSS) new Packet Data application software
product:

BSS21343 DLDC Territory Procedure


BSS21392 TRX Specific Link Adaptation for DLDC
BSS20083 Inter-BSC NACC
BSS21045 Inter System NACC
BSS21355 Inter System NACC for LTE
RG301397 Cositing with BS2xx

Soc Classification level


7
Nokia Siemens Networks

RN28193EN20GLA0

RN28193EN20GLA0

Flexi BSC Architecture and Interfaces

General BSC Block Diagram

Switching
Platform

Computing
platform

Soc Classification level


8
Nokia Siemens Networks

RN28193EN20GLA0

RN28193EN20GLA0

Flexi BSC Architecture and Interfaces

General BSC Block Diagram


Switching Platform:
GSW: Group Switch

Switching of internal and external PCMs

ET: Exchange Terminals

Adapts the external PCM circuits to the GSW

CLS: Clock and Synchronization unit

Distributes timing reference signals to the functional units of the BSC

Computing Platform:
OMU: Operation and Maintenance Unit

Maintenance functions

User interface

I/O device handling

BCSU: BSC Signalling Unit

Handles signalling links on A and Abis interfaces

Houses the PCU, that implements PS services in the BSC

MCMU: Clock and Synchronization unit

Controls and supervises the GSW

Soc Classification level


9
Nokia Siemens Networks

RN28193EN20GLA0

RN28193EN20GLA0

Flexi BSC Architecture and Interfaces

Flexi BSC Block Diagram

Soc Classification level


10
Nokia Siemens Networks

RN28193EN20GLA0

Refer to S15 Documentation:


BSC/TCSM descriptions\ BSC/TCSM hardware descriptions\
Engineering for Flexi BSC

RN28193EN20GLA0

10

Flexi BSC Architecture and Interfaces

Flexi BSC Product Highlights - RG20


The Worlds most powerful GSM/EDGE BSC

Up to 4200 TRXs
Over 25 000 Erl

Soc Classification level


11
Nokia Siemens Networks

Highest circuit-switched capacity for voice


Market-leading over 25,000 Erlangs from 4,200 TRXs
Very high packet data capacity for EDGE evolution
Up to 30,720 channels
Very high footprint efficiency
Low site-space costs thanks to 4,200 TRXs in one cabinet
Excellent power consumption efficiency
Market-leading power consumption per capacity
Support for most cost-efficient transport options
IP/Ethernet for all interfaces
Packet Abis and A over IP for additional efficiency
Full flexibility to configure preferred or mixed integrated
transmission type (E1/T1, STM-1/OC-3, IP/Ethernet)
Scalability
Capacity and transmission can be flexibly configured in small
resolution steps to support pay-as-you-grow approach
High reliability
Redundancy, fault management and overload protection on top
of very high availability design
Protected investment with strong evolution path
Flexi BSC module extension with Multicontroller BSC
Upgrade path for installed BSC3is to Flexi BSC

RN28193EN20GLA0

RN28193EN20GLA0

11

Flexi BSC Architecture and Interfaces

Flexi BSC Capacity Evolution


Flexi BSC with 3000 TRX

Flexi BSC with 4200 TRX

Higher capacity supported


with new Intel CPU card:
CP816 for 3000 TRXs
CP1D-A for 4200 TRXs

3,000 TRXs in RG10

Otherwise exactly the same


hardware in RG20

RG10/2009

Soc Classification level


12
Nokia Siemens Networks

4,200 TRXs in RG20

RG20/2010

RN28193EN20GLA0

RN28193EN20GLA0

12

Flexi BSC Architecture and Interfaces

Flexi BSC Capacity Evolution (RG20)


New Central Processing Unit CP1D-A
Characteristic
The Central Processor of 1st Dual core generation implemented using a Penryn SP9300
processor.

Supports SMP (Symmetrical Multiprocessing). A processor architecture in which multiple


CPUs share the same memory. None of the processors is in a special role (e.g. every
processor can handle any interruption, can schedule processes and can run any
scheduled process).

Main Features

Processor core speed 2.26 GHz max.


Memory size 8GB ( with 2GB dims)
PCI 33/32,PCI Express x4
ETH 4x1000Mbit/s
One USB 2.0 on front panel
1GB USB NAND flash module
CPCI 33Mhz,64bits

Soc Classification level


13
Nokia Siemens Networks

RN28193EN20GLA0

RN28193EN20GLA0

13

Flexi BSC Architecture and Interfaces

Flexi BSC Cabinet Configuration


Computer Units
Flexi BSC cabinet

MCMU

MCMU

BCSU

BCSU

MCMU

In the Flexi BSC, the call


control functions are
executed by microcomputers, called
Call Control Computers

OMU
OMU

BCSU

BCSU BCSU

BCSU

BCSU BCSU

2000 x 900 x 600 cabinet (HxWxD)


Soc Classification level
14
Nokia Siemens Networks

RN28193EN20GLA0

RN28193EN20GLA0

14

Flexi BSC Architecture and Interfaces

MCMU- Marker and Cellular Management Unit


MCMU

CP1D-A
SWPRO-C

MCMU

Plug-in units

MCMU

The Marker and Cellular Management Unit


(MCMU) controls and supervises the Bit
Group Switch and performs the hunting,
connecting and releasing of the switching
network circuits.
The cellular management functions of the
MCMU are responsible for cells and radio
channels that are controlled by the BSC.
The MCMU reserves and keeps track of the
radio resources requested by the MSC and
the handover procedures of the BSC.
MCMU also manages the configuration of
the cellular network.
Redundancy 2N

ESB24-D
PSC6-AB
Soc Classification level
15
Nokia Siemens Networks

RN28193EN20GLA0

RN28193EN20GLA0

15

Flexi BSC Architecture and Interfaces

Flexi BSC Hardware and Functionality


New SWPRO-C
Flexi BSC

PDFU

GSW2KB GTIC

ETC

ETC

CLS

GSW2KB GTIC

ETC

ETC

CLS

BCSU 1

OMU

BCSU 2 BCSU 3

BCSU 5 BCSU 6

FTRB
BCSU 4

MCMU

FTRB
MCMU

FTRB
BCSU

LANU

unit for a bit-oriented group switch (GSWB).


The GSWB control unit functionality provides
two control bus interfaces through the
backplane connection.
Processor Intel Celeron 1.0 GHz, 400 MHz with
SDRAM: 1 GB (with x8 memory configuration)
SWPRO-C allows to control higher amount of
connections and generates less load to the
MCMU CPU in comparison to SWCOP-A

PDFU

LANU

The SWPRO-C plug-in unit is used as a control

FTRB

SWPRO-C

Soc Classification level


16
Nokia Siemens Networks

RN28193EN20GLA0

RN28193EN20GLA0

16

Flexi BSC Architecture and Interfaces

BCSU- BSC Signalling Unit


The BSC Signalling Unit (BCSU) performs those

BCSU

BSC functions that are highly dependent on the


volume of traffic.
Consists of two parts, which correspond to the A
and Abis interfaces
Packet Control Units (PCUs) are housed in the
same cartridge.
The A interface part of the BCSU is responsible
for performing all message handling and
processing functions of the signalling channels
connected to it

Plug-in units

CP1D-A
AS7-D

BCSU

BCSU BCSU

BCSU

BCSU BCSU

PCU2-E
PSC6-D

Soc Classification level


17
Nokia Siemens Networks

Performing the distributed functions of the


Message Transfer Part (MTP) and the Signalling
Connection Control Part (SCCP) of SS7
Controlling the mobile and base station signalling
(Base Station Subsystem Application Part,
BSSAP)

The Abis interface part of the BCSU controls the


air interface channels associated with
transceivers (TRXs) and Abis signalling
channels.
The handover and power control algorithms
reside in this functional unit.
Redundancy N + 1

RN28193EN20GLA0

RN28193EN20GLA0

17

Flexi BSC Architecture and Interfaces

Flexi BSC Hardware and Functionality


New AS7-D (1/2)

Flexi BSC

ETC

ETC

GSW2KB GTIC

ETC

ETC

BCSU 1

MCMU

OMU

BCSU 2 BCSU 3

BCSU 5 BCSU 6

FTRB
BCSU 4

- Memory::SDRAM: 1 GB
- Capacity:

FTRB
MCMU

FTRB
BCSU

LANU

- L1 Instruction cache: 32 kB
L1 Write Back Data Cache: 32 kB
L2 Cache: 512 kB

GSW2KB GTIC

CLS

MHz FSB (Data quad pumped, 3.2 GB/s).

PDFU

CLS

purpose peripheral slot computing engine


- 512 HDLC channels (2x that of AS7-C), 8x
more memory, data processing performance is
estimated to be ~1.4x that of AS7-C
- an interface to OMC (X.25), then it is installed
in OMU.
- Processor and capacity Performance:
- Processor: Intel Celeron M ULV 1.0 GHz, 400

PDFU

LANU

- The AS7 plug-in unit function as a general

FTRB

Channels: 512
2M PCMs: 16 (32)

AS7-D PIU

Soc Classification level


18
Nokia Siemens Networks

RN28193EN20GLA0

Compare to AS7-B:
Processor : Intel Mobile Celeron 650 MHz, 100 MHz FSB (800 MB/s)
L1 Instruction cache: 16 kB
L1 Write Back Data Cache: 16 kB
L2 Cache: 256 kB
Memory : SDRAM: 128/256 MB
Capacity:
Channels: 256
2M PCMs: 10

RN28193EN20GLA0

18

Flexi BSC Architecture and Interfaces

Flexi BSC Hardware and Functionality


New AS7-D (2/2)
AS7_D 14 TRACK: 8
MS:FA000000 ME:FBFFFFFF IS:E240 IE:E27F
INT:20H
SW:0649005E
TSLS 30
20
10
0
LAPD
8M PCM: 400 B 11111111111111111111111111111111
R 11111111111111111111111111111111
CONNECTOR SIDE: HOR: VER: POINT: 1
LAPD

AS7_D 13 TRACK: 7
MS:F8000000 ME:F9FFFFFF IS:E200 IE:E23F
INT:22H
SW:0649005C
TSLS 30
20
10
0
CCS7
8M PCM: 416 B 11111111111111111111111111111111
R 11111111111111111111111111111111
CONNECTOR SIDE: HOR: VER: POINT: 1

8M PCM: 401 B 11111111111111111111111111111111


R 11111111111111111111111111111111
CONNECTOR SIDE: HOR: VER: POINT: 1

LAPD

LAPD

8M PCM: 402 B 11111111111111111111111111111111


R 11111111111111111111111111111111
CONNECTOR SIDE: HOR: VER: POINT: 1

LAPD

LAPD

8M PCM: 403 B 11111111111111111111111111111111


R 11111111111111111111111111111111
CONNECTOR SIDE: HOR: VER: POINT: 1

LAPD

LAPD

8M PCM: 404 B 11111111111111111111111111111111


R 11111111111111111111111111111111
CONNECTOR SIDE: HOR: VER: POINT: 1

8M PCM: 418 B 11111111111111111111111111111111


R 11111111111111111111111111111111
HOR: VER: POINT: 1

CONNECTOR SIDE:

8M PCM: 419 B 11111111111111111111111111111111


R 11111111111111111111111111111111
HOR: VER: POINT: 1

CONNECTOR SIDE:

8M PCM: 420 B 11111111111111111111111111111111


R 11111111111111111111111111111111
HOR: VER: POINT: 1

CONNECTOR SIDE:

LAPD

8M PCM: 431 B 11111111111111111111111111111111


R 11111111111111111111111111111111
CONNECTOR SIDE: HOR: VER: POINT: 2

LAPD

8M PCM: 415 B 11111111111111111111111111111111


R 11111111111111111111111111111111
CONNECTOR SIDE: HOR: VER: POINT: 2

Above is example of internal PCM connection for BCSU-1:


On track 8 : PCM 400 PCM 415 (16 PCMs) all TSL (0-31) used for LAPD
On track 7 : PCM 416 (1 PCM) all TSL (0-31) used for SS7, PCM 418-431 (14 PCM) all TSL (0-31) used for LAPD
Soc Classification level
19
Nokia Siemens Networks

RN28193EN20GLA0

RN28193EN20GLA0

19

Flexi BSC Architecture and Interfaces

OMU- Operating and Maintenance Unit


OMU

OMU is an interface between the BSC and a

OMU

Plug-in units
CP1D-A
AS7-D

SERO-B

Mass
memory
adapter:

PSC6-AB

DCAR1-A

HWAT-B

Soc Classification level


20
Nokia Siemens Networks

higher-level network management system and/or


the user. The OMU receives fault indications. It
can produce local alarm printouts to the user or
send the fault indications to NetAct
In a fault situation, the OMU automatically
activates appropriate recovery and diagnostics
procedures. Recovery can also be activated by
the MCMU if the OMU is lost.
The OMU consists of microcomputers and
contains I/O interfaces for local operation.
The tasks of the OMU can be divided into five
groups:

traffic measurement functions


maintenance functions
system configuration administration functions
system management functions
LAN topology management

RN28193EN20GLA0

RN28193EN20GLA0

20

Flexi BSC Architecture and Interfaces

NetAct link options in Flexi BSC


LAN (Ethernet) interface
LAN Ethernet interface according to IEEE802.3 for
faster access
This is the default NetAct link interface
Connected via CPRJ45 panel on top of the cabinet

Digital X.25 interface, AS7-D


(PCM time-slot-based O & M interface via A Interface, G.703)

An O&M interface via transcoders and transmission


equipment
Network management interfaces in PCM time slots

Should be used only if LAN is not available


The LAN interface redundancy is implemented by
providing a redundant LAN connection
The digital X.25 interface can optionally be
redundant by using duplicated units

Soc Classification level


21
Nokia Siemens Networks

RN28193EN20GLA0

The BSC has an X.25 and a LAN connection to the Nokia NetAct Operations Support
System (OSS). The interface between these two network elements is based on the OSI
protocol. Nokia NetAct interface plug-in unit are housed either with AS7 plug-in units or
with AC25 plug-in unit. LAN/Ethernet connection is always available in default BSC
configuration via connector panel with CPU in OMU.

RN28193EN20GLA0

21

Flexi BSC Architecture and Interfaces

Flexi BSC Mass memories


Hard Disk Units
Duplicated Hard disk units are installed with carrier
adapter per BSC to ensure high reliability
Easy to change or upgrade without traffic
interruption

USB memory stick interface


USB memory stick will provide reliable means for
backup copying SW and database on a
transferable media in BSC

Soc Classification level


22
Nokia Siemens Networks

RN28193EN20GLA0

Recommended solution for SW backups and for other additional disk storage
Easy, practical and fast to use compared to diskettes or DAT tape:
More reliable compared to Cartridge Tape (DAT) units
Media is more durable (compare Tape against CD-Rom)
MO has better heat endurance
MO is fast especially due to random Access -> Information can be read from media very fast
Maintenance is easier than with existing DAT solution
Drive and media has simple mechanical structure
Media is long-lasting
Disk drive is maintenance free
It is recommended that disk is cleaned at least every third month
BSC MO disk require correct MO disk adapter to be used. Currently ODPU-A adapter is accepted in BSC3i. Accepted units are
updated in BSC HW Revisionlist document.
MO 91 specifications:
Manufacturer: Sony
Model: SMO-F561-70 (Nokia Specific equipment)
Unformatted Capacity: 9.1GB (4.5GB/side)
Standards: SCSI-2
Rotational speed: 3000 rpm
Seek time (ms): min 2, ave 25, max 45
Internal transfer rate: 3.07 6.14 MB/s
SCSI transfer rate: async 3MB/s, sync 20 MB/s
Buffer size: 8 Mbyte
Rewritable media
Unformatted capacity of MO91 is 4.5GB per side of the media. Total unformatted capacity is 9.1GB. The drive has read/write
head only on side of the media. So disk needs to be turned around manually. Information is saved to the disk using
MSDOS/FAT 16 or MSDOS/FAT 32 format.

RN28193EN20GLA0

22

Flexi BSC Architecture and Interfaces

Flexi BSC Hardware and Functionality


DCAR1-A Plug in Unit

USB port in DCAR1-A


PIU

HDSAM (contained
HSD07) also in
DCAR1-A PIU

USB memory stick will provide

Duplicated Hard disk units are

reliable means for backup


copying SW and database on a
transferable media in BSC
Capacity of memory stick
is 4 GB

installed with carrier adapter per


BSC to ensure high reliability
Easy to change or upgrade
without traffic interruption
Capacity of HSD07 is 73 GB
Red - out of
Service
green Power
good
amber hard disk
drve activity

LED indicator on DCAR1A :


green normal operation
red failure condition

Blue Hot Swap

Hard disk AMC front panel


(HDSAM-A)
Soc Classification level
23
Nokia Siemens Networks

RN28193EN20GLA0

RN28193EN20GLA0

23

Flexi BSC Architecture and Interfaces

Flexi BSC Capacity Evolution on RG20

BCSU

MCMU

With RG20 (BSS) release, there will


be 4200 TRX capacity with 25000
Erlang from the same cabinet than
BSC3i 660 in S11.5, BSC3i 1000 in
S12 and Flexi BSC (S14) in S14
release.

MCMU

Flexi BSC, which was introduced with


RG10 (BSS) Release, is designed to
provide a leading capacity, low power
consumption and is fully flexible in
capacity and connectivity dimensions.

OMU

Cabinet configuration will be flexible


from 700 TRX to 4200 TRX in
6 capacity steps

BCSU

BCSU

BCSU

New CPU unit in OMU, MCMU and


BCSU of Flexi BSC: CP1D-A

BCSU

BCSU

BCSU

Soc Classification level


24
Nokia Siemens Networks

The CP816 PIUs


(in S14) are
replaced with new
CP1D-A PIUs (in
S15) on each
Computer Unit
(BCSU, MCMU,
OMU)

RN28193EN20GLA0

Summary:
The Flexi BSC was introduced with the RG10 (BSS) Release to complement the existing
members of the Flexi BSC product family - The BSC3i 660 and the BSC3i 1000/2000.
The Flexi BSC is designed to provide both a leading capacity and low power
consumption in a single cabinet solution and is fully flexible in capacity and connectivity
dimensioning.
With the RG20 (BSS) Release, this evolution is continued through the introduction of a
new Intel CPU enabling the capacity to be further extended to support up to 4200 TRXs
in one single cabinet.
Benefits for the Operator:
Every aspect of the Flexi BSC contributes to its high operational efficiency.
The solution offers a unique level of capacity efficiency - being the only BSC in the
marketplace to support up to 4200 TRXs in one cabinet, whilst providing the highest
traffic handling capacity of 25000 Erlang.
Additionally, it offers a new level of efficiency in transmission, through enabling the
Packet Abis and A over IP functions through the new ETP / ETP-A modules - which can
be also be used in the BSC3i 1000/2000 and TCSM3i.
The Flexi BSC, through offering full flexibility in configuration for different transmission
media will enable the operator to realise the most cost efficient solution for their
requirements.

RN28193EN20GLA0

24

Flexi BSC Architecture and Interfaces

Flexi BSC Cartridges (Other Units)


Flexi BSC cabinet
CLOC
GTIC

ETC

CLOC

GTIC

ETC

CLOC

GSW2KB GSW2KB

GSW2KB

LANU

ETC

LANU

LANU

GTIC

Soc Classification level


25
Nokia Siemens Networks

RN28193EN20GLA0

RN28193EN20GLA0

25

Flexi BSC Architecture and Interfaces

Flexi BSC Group Switch GSW2KB

Conveys the traffic passing


through the BSC
Establishes needed
connections to the signalling
units and the internal data
transmission channels

Internal connections to ET16 via


back panel and ETS2/ETIP1-A
via front panel

Is responsible for the


submultiplexing
functions of the BSC

Soc Classification level


26
Nokia Siemens Networks

Configuration includes 8 x
SW256B plug-in units

RN28193EN20GLA0

The duplicated Group Switch (GSWB) 256 is the switching fabric of the BSC3i. The GSWB is
housed in two identical SW1C-C cartridges, and it conveys the traffic passing through the BSC3i and
switches the tones to the subscribers of the exchange and to the trunk circuits. It also establishes
the needed connections to the signalling units and the internal data transmission channels, and is
responsible for the submultiplexing functions of the BSC3i.
The operation of the GSWB is controlled and supervised by the Marker and Cellular Management
Unit (MCMU; SWCOP-A).
Redundancy: 2n with MCMU
Type: Functional unit, sub-unit of the Marker and Cellular Management Unit
Plug-in units:
SW64B Switching Network (8 Bit/s channels)
PSC1-S Power Supply for Cartridge
The dimensions of an SW1C-C cartridge are (height x width): 270 mm x 198 mm
The dimensions of the plug-in units are (height x width): 233.4 mm x 220 mm; or
9.19 in x 8.66 in.

RN28193EN20GLA0

26

Flexi BSC Architecture and Interfaces

Flexi BSC Hardware and Functionality


SW256B PIU

The GSW2KB is a congestion-free, full availability single-step


switching network based on time-space architecture.
The maximum capacity of GSW2KB related hardware is 2048
PCM lines, which realized by having 8 x SW256B piu.
Interfaces:
- 64x8Mbit/s serial interface OR
- 32x4Mbit/s,32 x8Mbit/s serial interfaces OR
- 64x4Mbit/s serial interface
- 4 x 2N redundant Serial Broadband Interface (SBI) 524 MBit /s
for connecting the Hotlink from SET/ETIP

Soc Classification level


27
Nokia Siemens Networks

RN28193EN20GLA0

RN28193EN20GLA0

27

Flexi BSC Architecture and Interfaces

Flexi BSC Clock unit

Clock and Tone Generator


(CL3TG-UA) plug-in units
generates the basic timing
signals needed by the exchange,
either independently or
synchronized to a frame
alignment signal received from
the Exchange Terminal (ET) or
external Frequency Standard
(FS).

Number of synchronization
inputs: four from PCM (ET), and
two from expernal input (FS) via
connector panel

2 x CL3TG units
(2N redundancy)

Housed in the SGC1C-A


cartridge
Soc Classification level
28
Nokia Siemens Networks

RN28193EN20GLA0

The CLS generates the clock signals necessary for the BSC. The oscillator of the CLS is normally
synchronized to an external source, usually an MSC, through a PCM line. Up to three additional
PCM inputs are provided for redundancy.
Plug-in Unit:

CL3TG (Clock and Tone Generator)

Interfaces:
- Synchronization input from Transcoder
- External synchronization input
- Synchronization output
- Wired alarm interface to OMU via GSWB
The Clock&Tone Generator (CL3TG) plug-in unit meets the requirements of the ITU-T
Q.500 Series Recommendation with respect to the Time Interval Error (TIE), the jitter, the
wander, and the transfer function. In the plesiochronous operation mode, the frequency
shift of the CL3TG is 5 * 10-9 within each 24-hour period, if the temperature of the
environment does not vary. CL3TG with external synchronised input is available by using
the external synchronisation input connector from the CPRJ45 panel. It can be
implemented either by symmetrical or asymmetrical PCM connection (RJ45 or BNC
connector).

RN28193EN20GLA0

28

Flexi BSC Architecture and Interfaces

Flexi BSC ET units


ETC 0-4 and GTIC 0-1

Provides the

ETC 0-4
GTIC 0-1

external PCM line


connections for BSC
Each ET16 plug-in units
contain 16 separate
PCMs (E1/T1)
Only one ET16
plug-in unit type
Interface specific
characteristics are
changed with cabling
and cabling panels

Flexi BSC includes in


maximum 50 ET16 units
providing 800 external
PCMs (E1/T1)
Soc Classification level
29
Nokia Siemens Networks

RN28193EN20GLA0

The ETs are housed in ET4C-B cartridges. One ET4C-B cartridge can contain up to 32 ET2E-S,
ET2E-SC or ET2A plug-in units. The total number of ET plug-in units in the BSC3i is 62
(32 in ET4C0, 30 in ET4C1) and the total number of PCMs is 124.
The ET2 plug-in units are installed in the order presented in the Equipment list in the site
documents. The ET2E plug-in unit connects BSC to a 2.048 Mbit/s PCM transmission system.
The ET2E is equipped with two PCM circuit interfaces (2x2M).
Different connector types used in ET2-units are following:
ET2E-S Exchange Terminal with Euroconnector
(balanced E1interface, 120 ohm) in ETSI environment
ET2E-SC Exchange Terminal with coaxial connectors
(unbalanced E1 interface, 75 ohm) in ETSI environment
ET2A Exchange Terminal with RJ-45 connectors
(balanced T1 interface) in ANSI environment
The dimensions of a ET4C cartridges are (height x width): 270 mm x 360 mm
The dimensions of the ET2 plug-in units are (height x depth): 100 mm x 220 mm; or 3.94 x 8.66
in.

RN28193EN20GLA0

29

Flexi BSC Architecture and Interfaces

Flexi BSC SET units


Provides the external SDH
/ Sonet line connections for
BSC
Each ETS2 plug-in units
contain two separate STM1 / OC-3 interfaces
Flexi BSC includes in
maximum 2 x 8 ETS2 units
providing 16 external
interfaces (STM-1/OC-3)
ETIP1-A/ET16 units
can be equipped to
0 - 18 x ETS2 units
the same cartridge
0 - 18 x ETIP1-A units
0 - 17 x ET16 units
alternatively

Soc Classification level


30
Nokia Siemens Networks

RN28193EN20GLA0

The ETs are housed in ET4C-B cartridges. One ET4C-B cartridge can contain up to 32 ET2E-S,
ET2E-SC or ET2A plug-in units. The total number of ET plug-in units in the BSC3i is 62
(32 in ET4C0, 30 in ET4C1) and the total number of PCMs is 124.
The ET2 plug-in units are installed in the order presented in the Equipment list in the site
documents. The ET2E plug-in unit connects BSC to a 2.048 Mbit/s PCM transmission system.
The ET2E is equipped with two PCM circuit interfaces (2x2M).
Different connector types used in ET2-units are following:
ET2E-S Exchange Terminal with Euroconnector
(balanced E1interface, 120 ohm) in ETSI environment
ET2E-SC Exchange Terminal with coaxial connectors
(unbalanced E1 interface, 75 ohm) in ETSI environment
ET2A Exchange Terminal with RJ-45 connectors
(balanced T1 interface) in ANSI environment
The dimensions of a ET4C cartridges are (height x width): 270 mm x 360 mm
The dimensions of the ET2 plug-in units are (height x depth): 100 mm x 220 mm; or 3.94 x 8.66
in.

RN28193EN20GLA0

30

Flexi BSC Architecture and Interfaces

Flexi BSC EET units for CESoPSN*


Provides the external GigE
Ethernet line connections
for BSC
Each ETIP1-A plug-in units
contain one IP interfaces
Flexi BSC includes in
maximum 2 x 8 ETIP1-A
units providing 8 redundant
external interfaces (GigE)
ETS2/ET16 units can
be equipped to the
same cartridge
0 - 18 x ETS2 units
alternatively
0 - 18 x ETIP1-A units
0 - 17 x ET16 units

*Circuit Emulation Service over Packet Switched Networks


Soc Classification level
31
Nokia Siemens Networks

RN28193EN20GLA0

The ETs are housed in ET4C-B cartridges. One ET4C-B cartridge can contain up to 32 ET2E-S,
ET2E-SC or ET2A plug-in units. The total number of ET plug-in units in the BSC3i is 62
(32 in ET4C0, 30 in ET4C1) and the total number of PCMs is 124.
The ET2 plug-in units are installed in the order presented in the Equipment list in the site
documents. The ET2E plug-in unit connects BSC to a 2.048 Mbit/s PCM transmission system.
The ET2E is equipped with two PCM circuit interfaces (2x2M).
Different connector types used in ET2-units are following:
ET2E-S Exchange Terminal with Euroconnector
(balanced E1interface, 120 ohm) in ETSI environment
ET2E-SC Exchange Terminal with coaxial connectors
(unbalanced E1 interface, 75 ohm) in ETSI environment
ET2A Exchange Terminal with RJ-45 connectors
(balanced T1 interface) in ANSI environment
The dimensions of a ET4C cartridges are (height x width): 270 mm x 360 mm
The dimensions of the ET2 plug-in units are (height x depth): 100 mm x 220 mm; or 3.94 x 8.66
in.

RN28193EN20GLA0

31

Flexi BSC Architecture and Interfaces

Flexi BSC ETP/ETP-A units


Provides the Gigabit Ethernet
interface for Packet Abis (ETP)
and A over IP (ETP-A).
Each ETP plug-in unit contains 1
external Ethernet interface
comprising 2 redundant SFP
modules.
Depending on the A over IP
scenario, ETP-A is located either
in TCSM3i or BSC.
When installed in the BSC, ETP
plug-in units can be plugged in the
GTIC and ETC cartridges.

Soc Classification level


32
Nokia Siemens Networks

RN28193EN20GLA0

The ETs are housed in ET4C-B cartridges. One ET4C-B cartridge can contain up to 32 ET2E-S,
ET2E-SC or ET2A plug-in units. The total number of ET plug-in units in the BSC3i is 62
(32 in ET4C0, 30 in ET4C1) and the total number of PCMs is 124.
The ET2 plug-in units are installed in the order presented in the Equipment list in the site
documents. The ET2E plug-in unit connects BSC to a 2.048 Mbit/s PCM transmission system.
The ET2E is equipped with two PCM circuit interfaces (2x2M).
Different connector types used in ET2-units are following:
ET2E-S Exchange Terminal with Euroconnector
(balanced E1interface, 120 ohm) in ETSI environment
ET2E-SC Exchange Terminal with coaxial connectors
(unbalanced E1 interface, 75 ohm) in ETSI environment
ET2A Exchange Terminal with RJ-45 connectors
(balanced T1 interface) in ANSI environment
The dimensions of a ET4C cartridges are (height x width): 270 mm x 360 mm
The dimensions of the ET2 plug-in units are (height x depth): 100 mm x 220 mm; or 3.94 x 8.66
in.

RN28193EN20GLA0

32

Flexi BSC Architecture and Interfaces

Main interfaces of ETP and ETP-A units

Hotlinks for
GSWB i/f
Internal interface

ETP
ETP-A

1 + 1 GigE
External interface

Ethernet for
LANU i/f
Internal interface

Soc Classification level


33
Nokia Siemens Networks

RN28193EN20GLA0

RN28193EN20GLA0

33

Flexi BSC Architecture and Interfaces

External interface options with SFP modules


Electrical SFP GigE, RJ45 CAT5
Twisted pair copper, short haul, 100m

ETP / ETP-A

Optical SFP GigE, LC SX

Giga Ethernet

Multimode fiber, short haul, 500m

Optical SFP GigE, LC LX (coming soon)


Single mode fiber, long haul, 5km

Soc Classification level


34
Nokia Siemens Networks

RN28193EN20GLA0

RN28193EN20GLA0

34

Flexi BSC Architecture and Interfaces

Flexi BSC IP/Ethernet Interfaces


ETIP1-A (PWE/CESoPSN), ETP (Packet Abis), ETP-A (A over IP)
ETIP1-A

Abis (CESoPSN)

1+1 x GigE
(CESoPSN)
Optical short haul
or copper SFP module

Ater (CESoPSN)
A (CESoPSN)
ETS2

ETP
1+1 x GigE
Optical short haul
or copper SFP
module

2 x STM-1
Optical long haul SFP
modules

Packet Abis (TDM)

Packet Abis (Eth)


ETP-A
1+1 x GigE
Optical short
haul
or copper SFP
module

Soc Classification level


35
Nokia Siemens Networks

A over IP

RN28193EN20GLA0

ETP
1+1 x Gigabit Ethernet port (SFP module)
Optical SFP GigE, LC SX short haul
Electrical SFP GigE, RJ45 CAT5
Packet Abis
Packet Abis over TDM (MLPPP)
Together with ETS2
Synchronization Options:
Synchronous Ethernet
Timing over Packet (IEEE1588v2)
ETP-A
Same capabilities as ETP, but is used for A over IP
in BSC (if Transcoder in MGW)
in TCSM3i (if Transcoder in BSS)
Hot standby redundant units applied for equipment protection
Additionally ETP-A cards require SFP modules, either electrical or optical
always two per card
Electrical SFP GigE, RJ45 CAT5 (sales item BSC3222)
Optical SFP GigE, LC SX (sales item BSC3214)

RN28193EN20GLA0

35

35

Flexi BSC Architecture and Interfaces

Flexi BSC PCU Solution


PCU - Packet Control Unit - a functional unit in Base Station Controller (BSC)
Controls (E)GPRS radio resources and acts as the key unit in the
following procedures
(E)GPRS Radio resource allocation and management
(E)GPRS radio connection establishment and management
Data transfer
Coding scheme selection
PCU statistics
Independent processing unit, embedded in BCSUs of BSC for
redundancy purposes
Takes advantage of BSCs O&M and overload protection
mechanisms
Provides flexible choices for transport method between BSC and
SGSN
IP and Frame Relay as transport alternatives for Gb - Interface

Soc Classification level


36
Nokia Siemens Networks

RN28193EN20GLA0

RN28193EN20GLA0

36

Flexi BSC Architecture and Interfaces

PCU2 Embedded in BCSUs of Flexi BSC


Flexible capacity extensions according to traffic needs
Configured into BCSUs according to traffic requirements
PDFU 0

Up to 5 PCU2-E plug-in units per BCSU


Asymmetrical PCU HW configuration allows PCU2-E HW

PDFU 1

installation in granularity of one


GTIC ETC
0
0

BCSU 1

LANU 0

BCSU 2

LANU 1

FTRB 2

MCMU 1

BCSU 0

Flexible and smooth capacity activation according to traffic


requirements

PCU2-Es are SW activated with license keys in granularity of 256


Abis channels

FTRB 1
MCMU 0

FTRB 0

ETC
3

CLS 1

GTIC ETC
1
2

GSW2KB-A
1

ETC
1

CLS 0

GSW2KB-A
0

OMU

BCSU 3

BCSU 5

FTRB 3

BCSU 4

Soc Classification level


37
Nokia Siemens Networks

BTS Objects

TRX Objects

Abis Channels

Up to 30 x 384

Up to 30 x 1,024

Up to 30 x 1,024

BCSU 6

RN28193EN20GLA0

RN28193EN20GLA0

37

Flexi BSC Architecture and Interfaces

Flexi BSC LANU units


2N redundant LANU unit in
basic cabinet
Contains 3 ESB24-D PIUs
For BSC3i 1000/2000,
theres another 2N
redundant LANU unit in
extension cabinet
Only if more than 6
working BCSUs in use
Extension to LANU in
basic cabinet
Contains 1 ESB unit
Soc Classification level
38
Nokia Siemens Networks

RN28193EN20GLA0

In the BSCC cabinet, LAN switches are used to collect CPU LANs to and from computer
units and PCU LANs to and from BCSU cartridges.
In the BSCC cabinet, there are two LANU parts in diffrerent BC1C-B cartridges. LANU 0
and LANU 1 are equipped with three ESB24-D plug-in units and a power unit PSC6-CB
ESB24-D switching unit with:
4 SFP type ports in the front panel (for optical and electrical RJ45 transceivers and SFP
DA transceivers)
20 full duplex Ethernet ports in the back plane (type 10/100/1000Base-T/TX/T)

RN28193EN20GLA0

38

Flexi BSC Architecture and Interfaces

Flexi BSC SWU units


Each ESB card in the LANU is considered a
Switching Unit (SWU)
The SWUs switch traffic from user plane
(e.g. Gb over IP), control plane (e.g.
SIGTRAN on A-IF) and management plane
(e.g. Q3 IF to NetAct)
The first SWU of the LANU cartridge is
connected to the CPUs of the BSC
computing units (OMU, MCMUs and
BCSUs)
Second and third SWUs are connected to
the PCUs

Soc Classification level


39
Nokia Siemens Networks

RN28193EN20GLA0

Refer to S15 Documentation:


BSC/TCSM descriptions\ Product description of Flexi BSC\ Architecture
of the Flexi BSC\ LAN Switch Units

RN28193EN20GLA0

39

Flexi BSC Architecture and Interfaces

ESB24-D Ethernet Switches


MCMU

LANU

Used in Flexi BSC for EMB and IP LAN switching


ESB unit located in MCMU is used for EMB switching
Connects all CPUs
ESB units located in LANU are used for IP LAN Switching
3 in base cabinet LANU
Connects together all CPUs and all PCUs
Soc Classification level
40
Nokia Siemens Networks

RN28193EN20GLA0

ESB24-D is the integrated IP/Ethernet switching unit (SWU) for BSC and contains 24
Gigabit Ethernet ports
In front panel there are:
2 x Optical SFP GigE, SX short haul
2 x Electrical SFP GigE, RJ45 CAT5
1 MGT ports (RJ45) serial port for switch management
1 SER1 ports (RJ45) console connector used for initial configuration
In back panel there are:
20 Full-duplex 10/100/1000Base T/TX ethernet Ports

RN28193EN20GLA0

40

Flexi BSC Architecture and Interfaces

PCU LAN

ETP LAN

CPRJ45 panel

SWUs 0 and 1 connect the CPUs from


OMU, MCMUs and BCSUs.
SWUs 2, 3, 4 and 5 connect all of the
PCUs in the BSC.
If ETP cards are used (in case Packet
Abis or AoIP are implemented), each
LANU should be expanded with an
additional ESB PIU for ETP LAN.
Those additional ESB PIUs are SWU 6
and 7.

SWU 7 SWU 6

CPU LAN

SWU 5 SWU 4 SWU 3 SWU 2 SWU 1 SWU 0

Flexi BSC LAN topology

Soc Classification level


41
Nokia Siemens Networks

RN28193EN20GLA0

RN28193EN20GLA0

41

Flexi BSC Architecture and Interfaces

Flexi BSC Hardware and Functionality


Flexi EMB connection principle Flexi BSC

Switched LAN is used


LAN is 2N redundant
EMB LANs are
physically separate
from the internal LAN

cabling & LAN-switches


used by the internal LAN
have been excluded from
the picture

Each computer reads


its EMB address from
EMB address plug

EMB address has same


value as MB address

CPUs with 4 LAN ports


- 2 used for redundant EMB

Soc Classification level


42
Nokia Siemens Networks

RN28193EN20GLA0

RN28193EN20GLA0

42

Flexi BSC Architecture and Interfaces

BSC3i 1000/2000 Hardware and Functionality


EMB Addressing
ADMODxx, Address Module connector
ADMODxx is going to be connected into rear of CP816-A PIU to
make Ethernet MB address.
There are total of 32 different ADMOD address module
connectors available: ADMOD00 ADMOD31.
ADMODxx has 2x5 size 2mm Z-pack HM cable connector.
A
A

Soc Classification level


43
Nokia Siemens Networks

RN28193EN20GLA0

EMB interconnects the functional units of BSC. The EMB consists of a redundant L2 LAN
Switch and LAN cables from computer units.
For commands to create EMB LAN, please refer to RG20 Documentation:
\Commission\ BSC/TCSM\ Commissioning Flexi BSC\ Checking the EMB in Flexi BSC

RN28193EN20GLA0

43

Flexi BSC Architecture and Interfaces

Exercise: BSC interrogation (1/2)

MGW/TCSM

ET

ET

ET

ET
ET

ET

SGSN

BTS

ET

ET

Soc Classification level


44
Nokia Siemens Networks

RN28193EN20GLA0

Exercise: BSC Interrogation, duration ~ 30min


Required equipment: one working VDU terminal for each workgroup.
Complete the picture above according to your classroom BSC!
Write down the used MML commands!
How many BCSUs are available?
______________________________________________________________________
How many SWUs are configured and what kind of ESB card is in use? Interrogate the
Plug-in Unit info.
______________________________________________________________________
______________________________________________________________________
How many ETs are in use?
______________________________________________________________________

RN28193EN20GLA0

44

Flexi BSC Architecture and Interfaces

Exercise: BSC interrogation (2/2)

MGW/TCSM

ET

ET

ET

ET
ET

ET

SGSN

BTS

ET

ET

Soc Classification level


45
Nokia Siemens Networks

RN28193EN20GLA0

With the ZWUP-Command you can check whether an ET is used for A-IF, Abis-IF or GbIF. How?
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
Interrogate the plug-in units of the OMU (ZWTI)!
Track .....:__________
Track .....:__________
Track .....:__________
Track .....:__________
Track .....:__________
Track .....:__________
Track .....:__________
Track .....:__________
Track .....:__________
Track .....:__________
Track .....:__________
Track .....:__________
Track .....:__________

RN28193EN20GLA0

45

Potrebbero piacerti anche