Power Supplies
Transformers
Power Monitoring
Bulletin 1404 Powermonitor 3000 ........................................................................................................ Page 8-76
Bulletin 4983-DD DIN Rail Dataline Surge Protective Device ................................................................ Page 8-87
Bulletin 4983-PF Panel Mount Filter ........................................................................................................ Page 8-89
Bulletin 4983-DC DIN Rail Combination Filter and Surge Protective Device ........................................ Page 8-93
10
11
12
13
www.ab.com/catalogs
Publication A117-CA001A-EN-P
8-1
Bulletin 1607
0
1
2
3
Table of Contents
Standards Compliance
Certifications
UL 508, UL 60950
CSA C22.2 No. 14
CSA C22.2 No. 60950-1
EN/IEC 60950
Type
Bulletin
Output Power
Input Voltage (47...63 Hz)
Single Output
1607-XT100D1A
1607-XT200D1A
1607-XT200D2A
50 W
91.2 W
>88%, 120V AC
>89%, 230V AC
>82%, 120V AC
>85%, 230V AC
Efficiency
Output Voltage
6
7
24V (+1%)
2.1 A
3.8 A
8A
-25...+70 C
derate 2%/K,
50...70 C
-25...+70 C
derate 2.5%/K, 50...70 C
-25...+70 C
derate 2%/K,
50...70 C
-25...+70 C
derate 2%/K,
50...70 C
Non-Operating
Temperature Range
-40...+85 C
Standards Compliance
Certifications
Special Features
Dual Output
1607-XT50D1A
Product Selection
page 8-3
8
9
10
11
12
13
www.ab.com/catalogs
8-2
Publication A117-CA001A-EN-P
NEC Class 2
Bulletin 1607
Product Selection/Accessories
Product Selection
Input Voltage
Inrush Current
Cat. No.
Single Output
50
100240V AC,
100353V DC
91.2
100240V AC,
100353V DC
2.0
24 (+1%)
24 (+1%)
1607-XT50D1A
<25 A
3.8
1607-XT100D1A
<25 A
1607-XT200D1A
<25 A
1607-XT200D2A
Dual Output
100240V AC,
100300V DC
24 (+1%)
2
Accessories
Cordsets
Straight Female
Type
No. of Pins
Assembly Rating
Straight Male
889N-M4AFC-1F
889N-E4AFC-1F
Cat. No.
Input
3-Pin
600V, 13 A
889N-F3AFC-1F
889N-R3AFC-1F
Output
4-Pin
600V, 10 A
1 Replace symbol with 6 (6 ft), 12 (12 ft), or 20 (20 ft) for standard cable lengths.
4
5
Patchcords
Straight Female
Straight Male
Straight Female
Right Angle Male
Type
No. of Pins
Assembly Rating
Input
3-Pin
600V, 13 A
889N-F3AFNM-
889N-F3AFNE-
889N-R3AFNM-
889N-R3AFNE-
Output
4-Pin
600V, 10 A
889N-F4AFNM-
889N-F4AFNE-
889N-R4AFNM-
889N-R4AFNE-
Cat. No.
Replace symbol with 1 (1 m), 2 (2 m), 5 (5 m), or 10 (10 m) for standard cable lengths.
Terminal Chambers
Straight Female
Straight Male
Type
No. of Pins
Assembly Rating
Input
3-Pin
250V, 12 A
871A-TS3-N1
Output
4-Pin
250V, 9 A
871A-TS4-NM1
7
8
Cat. No.
T-Ports
Type
No. of Pins
Input
3-Pin
Output
4-Pin
Assembly Rating
Cat. No.
898N-33PB-N4KF
300V 8 A
898N-43PB-N4KF
10
No. of Pins
Assembly Rating
Input
3-Pin
250V, 13 A
Output
4-Pin
600V, 10 A
Thread Size
1/2 in. - 14 NPT
Male
11
Cat. No.
888N-D3AF1-F
888N-M4AF1-F
Description
Cat. No.
Mounting nuts for 1/2 inch-14 NPT threaded receptacles are available in bags of 10 pieces
889A-U1NUT-10
12
13
www.ab.com/catalogs
Publication A117-CA001A-EN-P
8-3
Bulletin 1607
0
1
2
Description
Cat. No.
1732D-IB16M12M12
1732D-IB16M12MINI
1732D-OB16M12M12
1732D-OB16M12MINI
1732D-16CFGM12M12
1732D-16CFGM12MN
1732D-8X8M12D
DeviceNet, I/O Module with Diagnostics, 8 Sink Inputs (2 each on 4 connectors), 8 Source Outputs (2 each on 4 connectors),
1.4/8.0 A per Point/Module, DC Micro (M12) connector
1732D-8X81212HD
3
4
1738-ADN12
1738-ADNX
ArmorPoint DeviceNet Adapter Module, Drop or Pass-through, with male and female M18 connectors
1738-ADN18P
ArmorPoint DeviceNet Adapter Module, Drop only, with male M18 connector
1738-ADN18
1738-ACNR
1738-AENT
1792D-CB18P
Note: Review exact user and adapter power requirements for all digital products.
Note: The On-Machine power supplies are designed so that user and adapter power are wired in parallel. Also, the following conditions exist:
Total power (user plus adapter power) equals the On-Machine power supply output channel.
Both user and adapter power are +24V DC.
User and adapter power are common and not isolated.
Specifications
6
7
Output Power
1607-XT50D1A
1607-XT100D1A
1607-XT200D1A
1607-XT200D2A
50 W
91.2 W
192 W
(288 W with bonus power)
Operational Range
Hold-up Time
Rated Input Current
50 ms
1.0 A (115V AC),
0.5 A (230V AC)
Inrush Current
8
9
>82%, 120V AC
>85%, 230V AC
Output Voltage
24V (+1%)
2.0 A
3.8 A
Noise
AC Power On LED
Indication for Output 1
Operating Temperature
Range (Tamb)
12
Special Features
13
-40...+85 C
up to 100% with condensation
>500 000 hours
187 x 74 x 122 mm (7.36 x 2.91 x 4.80 in.)
Ingress Protection
Certifications/Standards
IP67, EN 60529
CE, UL 508 (UL LISTED), UL 60950 (cURus), Safety standards = IEC/EN 60950, EN 60529
CE EN 60950; cULus Listed, UL508, cURus Recognized UL60950/CSA C22.2, No. 60950-1
NEC Class 2
www.ab.com/catalogs
8-4
-25...+60 C
derate 2%/K, 50...60 C
MTBF
Weight
-25...+70 C
derate 2.5%/K, 50...70 C
Humidity
Dimensions (W x H x D)
yes
Non-Operating
Temperature Range
11
8A
Ripple Voltage
Overcurrent Protection
10
<25 A
>88%, 120V AC
>89%, 230V AC
Efficiency
Publication A117-CA001A-EN-P
NEC Class 2
Bulletin 1607
Specifications/Approximate Dimensions
Pinouts
Input
Output
0
1
2
Pin
Connection
Pin
Connection
NC
Approximate Dimensions
Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.
1607-XT50D1A and 1607-XT100D1A
5
Location of
Keying Tab
130
(5.11)
6
85 (3.35)
74 (2.91)
7
35 (1.38)
140
(5.51)
1607-XT200D1A
Location of
Keying Tab
1607-XT200D2A
225
(8.86)
Location of
Keying Tab
6.6
9
10
225
(8.86)
122 (4.80)
6.6
11
122 (4.80)
100 (3.94)
100 (3.94)
245
(9.65)
245
(9.65)
12
74 (2.91)
74 (2.91)
22 (0.87)
22 (0.87)
187
(7.36)
187
(7.36)
www.ab.com/catalogs
13
Publication A117-CA001A-EN-P
8-5
Bulletin 1606
Power Supplies
Product Overview
0
1
Bulletin
Type
Output Power
1606-XLP
Essential
Single/Three-Phase
Compact
Single/Two-Phase
80...960 W
80...960 W
15100 W
100240, 323576V AC
91.6...95%
90...92%
80...90%
Rated Output
Current
3.340 A
3.340 A
0.64.5 A
Operating
Temperature
Range
-25+70 C
>60 C with derating
-25+70 C
>60 C with derating
-40+70 C
>60 C with derating
Output Voltage/
Secondary
Voltage
Non-Operating
Temperature
Range
Certifications
5
Standards
Compliance
6
7
1606-XLE
Input Voltage/
Primary
Voltage
Efficiency
1606-XLS
Performance
Single/Three-Phase
-40+85 C
cULus, CE, GL, ATEX
EN 50081-1,
EN 61000-6-2,
EN 61000-3-2 (A14),
UL 508, UL 60950,
CAN/CSA C22.2 No. 60950,
RoHS
Class 1, Div. 2
Special
Application
Products
Product
Selection
Page 8-9
Page 8-10
8
9
10
11
12
13
www.ab.com/catalogs
8-6
Publication A117-CA001A-EN-P
Page 8-11
Bulletin 1606
Power Supplies
Selection Information
Bulletin 1606 Power Supplies1
Table of Contents
Product Sizing
Quick Guide
Special Applications
Catalog Number
Explanation
Product Selection
Specifications and
Approximate
Dimensions
this page
8-8
8-8
0
1
8-9
8-9
8-13
Special Modules
Standards Compliance
World-wide Certifications
NEC Class 2
Class 1 Div. 2 (T3A)
Certifications
4
5
1 Not all features apply to all power supplies; see individual power supply descriptions for specifics
A more detailed list of performance specifications can be found at the Allen-Bradley web site
http://www.ab.com/industrialcontrols/products/power_supplies/index.html
IRATED: 5 A
ISHORT CIRCUIT: >9 A
IPOWER BOOST: 7.5 A
2. Select a power supply where the rated load is at/or below the current of
the device and the Peak Current is less than the short-circuit rating of the
power supply.
Notes:
ReservePower will deliver up to 25% additional current continuously.
PowerBoost will deliver 150% of rated current for up to 5 s.
Output Voltage
1. Determine the "Average" continuous current of the load and the typical
inrush current.
7
8
Example:
Output Current
Solution: 1606-XLS120E
Cat. No.
IRATED [A]
ISHORT CIRCUIT
(25 C) [A]
IPOWER BOOST or
IRESERVEPOWER [A]
1606-XLS80E
3.3
5.2
5.4
1606-XLS120E
7.5
1606-XLS240E
10
21
15
1606-XLS480E
20
30
30
1606-XLS480E-3
20
29
30
1606-XLSDNET4
3.8
1606-XLSDNET8
1606-XLE80E
3.3
5.5
3.6
1606-XLE120E
11
1606-XLE240E
10
16
12
10
11
12
www.ab.com/catalogs
Publication A117-CA001A-EN-P
8-7
13
Bulletin 1606
Power Supplies
Quick Guide/ Special Applications
0
1
Quick Guide
Bulletin 1606-(number from table) Power Supply Quick Guide
15...40 W
50 W
60 W
72...80 W
90...100 W
120 W
180 W
240 W
480 W
720 W
960 W
5...5.5V
XLP15A
XLP25A
10...12V
XLP30B
XLP15B
XLP50B
XLP60BQ
XLP60BQT
XLP90B
XL180B
12...15 V 3-Ph
XLE96B
XLP36C
XLS240E
XLS240EC
XLE240E
XLE240EP
XLE240EE
XLE240EN
XLS480E
XLS480EA
XLS480EC
XLS480EE
XLS960EE
12...15V 1-Ph
2
24...28V 1-Ph
XLP15E
XLP30E
XLP30EQ
XLP50E
XLP50EZ
XL60D
XLP60EQ
XLP60EQT
XLS80E
XLE80E
XLP72E
24...28V 2-Ph/3Ph
36...43V
XLP95E
XLP100E
XLS120E
XLS120EA
XLE120E
XLE120EC
XLE120EE
XLE120EN
3
4
5
48...56V 1-Ph
XLP50F
48...56V 3-Ph
24V Redundant
XL60DR
DeviceNet
XLP90E-2
XLE120E-2
XLP100E-2
XLP100F
XL120DR
XLEDNET3 XLSDNET4
XL240E-3C XLS480E-3
XLE240E-3 XLS480E-3C
XLE240F
XL720E-3
XLS480G-3
XLS480F
XLE960DX3N
XLS960E-3
XLS960FE
XLE960MX
-3N
XLS960F-3
XLE240F-3
XLS480F-3
XL240DR
XLSDNET8
Example: For a 24...28 Volt, 3-Phase, 120 Watt power supply, the Cat. No. would be 1606-XL120E-3.
Special Applications
NEC Class 2
ABS/GL Marine
Hazardeous Location
Rating, Class 1 Div 2
ODVA Requirements
Conformal Coating
ATEX
1606-XLE
XLE80E
XLEDNET3
XLE120EC
1606-XLP
XLP15A
XLP15B
XLP15E
XLP25A
XLP30B
XLP30E
XLP36C
XLP50B
XLP50E
XLP50EZ
XLP50F
XLP72E
XLP90B
XLP90E-2
XLP95E
XLP15A
XLP15B
XLP15E
XLP25A
XLP30E
XLP36C
XLP50E
XLP50EZ
XLP72E
XLP90B
XLP100E
XLP100F
XLPRED
XLP15A
XLP15B
XLP15E
XLP25A
XLP30B
XLP30E
XLP50B
XLP50E
XLP50EZ
XLP72E
XLP90B
XLP95E
XLP100E
XLPRED
XLSDNET4
XLSDNET4
XLSDNET8
XLS240EC
XLS480E-C
XLS480E-3C
XLS120EA
XLS240EA
XLS480EA
Bulletin Number
7
8
9
10
1606-XLS
11
12
13
www.ab.com/catalogs
8-8
Publication A117-CA001A-EN-P
Bulletin 1606
Power Supplies
Catalog Number Explanation/Product Selection
Catalog Number Explanation
Important: The following cat. no. breakdown is for explanation purposes only. It is not a product configurator. Not all combinations of fields
are valid product cat. nos. First, select the desired power supply using the Product Selection tables. Then, use this breakdown for verification
and explanation only.
1606 XLS
a
480
3
d
Output Voltage
Multi-Phase Variations
Code
Description
Code
Description
Code
Description
XLP
Compact family
15
15 W
5V DC
XLS
Performance family
25
25 W
XLE
Essential family
30
30 W
10...12V DC or 12...15 V
DC
36
36 W
40
40 W
24V DC
50
50 W
24...28V DC
60
60 W
48...56V DC
72
72 W
36...43V DC
80
80 W
48V DC
90
90 W
95
95 W
100
100 W
120
120 W
180
Code
Description
d
Special Functions
-2
Two phase
-3
Three phase
-3C
-3H
-3N
-D
360...900V - DC Only
Description
180 W
Conformal coating
240
240 W
Redundancy module
480
480 W
720
720 W
Removeable Terminations
960
960 W
Semi-Regulated
Regional voltage;
230V AC input only
Regional voltage;
120V AC input only
ATEX
100...240V AC,
110...300V DC
Output
Power [W]
Output
Voltage
Output
Current [A]
80
2428
3.3
120
2428
120
2428
180
1215
15
240
2428
240
2428
240
2428
10
240
4856
240
480
6
7
Steady State
Input Current
120/230
Parallel
[V AC]
Operation DC OK Relay
8
Cat. No.
1.41/0.82
Yes
1606-XLS80E
1.10/0.62
Yes
1606-XLS120E
1.10/0.62
Yes
1.65/0.93
Yes
10
2.22/1.22
Yes
10
2.22/1.22
Yes
1606-XLS240EA
2.22/1.22
Yes
1606-XLS240EC
2.22/1.22
Yes
1606-XLS240F
2832
2.22/1.22
Yes
1606-XLS240K
2428
20
4.56/2.48
Yes
480
2428
20
4.56/2.48
Yes
1606-XLS480EC
480
24...48
20
4.56/2.48
Yes
1606-XLS480EA
4.56/2.48
Yes
1606-XLS480F
4.56/2.48
Yes
1606-XLS480G
/4.6
Yes
1606-XLS960EE
200...240V AC
480
4856
10
100...240V AC,
110...300V DC
480
3642
13.3
200...240V AC,
220...300V DC
960
2428
40
1606-XLS120EA
1606-XLS240E
10
1606-XLS480E
11
12
13
Publication A117-CA001A-EN-P
1606-XLS180B
Unit has internal (not accessible/replaceable) input fuse. Additional protection is not required if used on branch circuits UL test levels.
Consult local codes and regulations for installation.
The C suffix in the Cat. No. indicates that the product has conformal coating.
1 The A suffix in the Cat. No. indicates that the product carries the ATEX rating.
www.ab.com/catalogs
4
5
Input Voltage
Code
Product Selection
8-9
Bulletin 1606
Power Supplies
Product Selection
Three-Phase
0
Output
Power [W]
Output
Voltage
Output
Current [A]
380480V AC,
600V DC
480
2428
20
380480V AC,
600V DC
480
2428
20
Input Voltage
1
2
3
Steady State
Input
Current
400...480 [V
Parallel
AC]
Operation DC OK Relay
Cat. No.
Yes
Yes
Yes
1606-XLS480E-D
Yes
1606-XLS480F-3
Yes
1606-XLS480G-3
Yes
1606-XLS960E-3
Yes
1606-XLS960F-3
1606-XLS480E-3
3 x 0.65
360900V DC
480
2428
20
380480V AC,
600V DC
480
4856
10
380480V AC,
600V DC
480
3642
13.3
380480V AC,
600V DC
960
2428
40
380480V AC,
600V DC
960
3 x 0.85
6 A Slow Blow Fuse or
Cat. No. 1489-A3C060
1606-XLS480E-3C
3 x 0.65
3 x 1.35
48...54
20
4
Output Power
[W]
Output
Voltage
Output
Current [A]
80
2428
3.3
1.5/0.68
No
1606-XLE80E
2428
2.34/1.23
No
1606-XLE120E
2428
2.34/1.23
No
90132V AC
2428
1.23/
No
1606-XLE120EN
180264V AC
2428
/1.17
No
1606-XLE120EE
Input Voltage
100120/200
240V AC
100120/200
240V AC
6
7
8
Steady State
Input Current
Parallel
120/230 [V
Operation DC OK Relay
AC]
100120/200
240V AC
120
Cat. No.
1606-XLE120EC
100120/200
240V AC
2428
10
4.34/2.23
No
1606-XLE240E
90132V AC
2428
10
3.73/
Yes
1606-XLE240EN
2428
10
/2.20
No
1606-XLE240EE
100120/200
240V AC
180264V AC
2428
10
4.34/2.00
No
1606-XLE240EP
100120/200
240V AC
4852
4.34/2.23
No
1606-XLE240F
240
9
Output Power
[W]
Output
Voltage
Output
Current [A]
380480V AC,
600V DC
96
12...15
2 x 0.56
1606-XLE96B-2
380480V AC,
600V DC
120
2428
3 x 0.60
1606-XLE120E-2
380480V AC,
600V DC
240
2428
10
380480V AC,
600V DC
240
48...56
3 x 0.60
1606-XLE240F-3
480V AC
960
24
40
3 x 1.40
1606-XLE960DX-3N
480V AC
960
48
20
3 x 1.40
1606-XLE960MX-3N
Input Voltage
10
11
12
Steady State
Input Current
Parallel
400...480 [V
Operation DC OK Relay
AC]
0.68
No
Unit has internal (not accessible/replaceable) input fuse. Additional protection is not required if used on branch circuits UL test levels.
Single/parallel operation (inclined characteristic) selectable (jumper). Consult local codes and regulations for installation.
Parallel use for 1 + 1 redundancy only.
The C suffix in the Cat. No. indicates that the product has conformal coating.
13
www.ab.com/catalogs
8-10
Publication A117-CA001A-EN-P
Cat. No.
1606-XLE240E-3
Bulletin 1606
Power Supplies
Product Selection
1606-XLP Compact Single- and Two-Phase
Single-Phase
Input Voltage
Output Power
[W]
15
25
30
100240V AC,
85375V DC
36
50
54
0
Steady State
Input Current
Parallel
120/230 [V AC] Operation
Output
Voltage
Output
Current [A]
55.5
0.28/.017
1215
1.3
0.28/.017
2428
0.6
0.28/.017
Yes
Cat. No.
1606-XLP15A
1606-XLP15B
1606-XLP15E
55.5
0.60/0.30
1012
0.60/0.25
2428
1.3
+/- 12/15V
2.8
0.65/0.40
1215
4.2
1.00/0.60
2428
2.1
0.77/0.44
Yes
1606-XLP50E
2428
2.1
1.00/0.60
Yes
1606-XLP50EZ
1.00/0.60
Yes
1606-XLP50F
0.91/0.54
Yes
1606-XLP60BQ
1606-XLP60BQT
4856
12...15
4.5
Yes
DC OK Relay
0.60/0.35
Yes
1606-XLP25A
1606-XLP30B
1606-XLP30E
1606-XLP30EQ
No
1606-XLP36C
Yes
1606-XLP50B
0.54/0.30
54
12...15
4.5
0.97/0.61
Yes
60
24...48
2.1
0.98/0.58
Yes
1606-XLP60EQ
60
24...48
2.1
1.05/0.66
Yes
1606-XLP60EQT
100120/220
240V AC,
220375V DC
72
2428
1.60/0.80
Yes
1606-XLP72E
90
1215
7.5
1.90/0.90
Yes
1606-XLP90B
100200/200
240V AC,
220375V DC
95
2428
3.9
2.00/0.95
No
1606-XLP95E
2428
4.2
2.10/1.00
Yes
1606-XLP100E
4856
2.1
2.10/1.00
Yes
1606-XLP100F
Steady State
Input Current
400...480 [V
AC]
Parallel
Operation
DC OK Relay
Cat. No.
2 x 0.36
No
1606-XLP90E-2
2 x 0.40
Yes
1606-XLP100E-2
100
1
2
3
4
5
6
Two-Phase
Input Voltage
Output Power
[W]
Output
Voltage
Output
Current [A]
380480V AC
90
2428
3.75
380480V AC
100
2428
4.2
7
8
Unit has internal (not accessible/replaceable) input fuse. Additional protection is not required if used on branch circuits UL test levels.
Single/parallel operation (inclined characteristic) selectable (jumper). Consult local codes and regulations for installation.
9
Bulletin 1606 Back-of-Panel Brackets
Instead of snapping the power supply onto a DIN Rail, you can mount it to the back of the panel. This set consists of two steel brackets
which replace the existing DIN Rail aluminum brackets at the back of the unit.
Note: You need one set per unit.
Description
10
Cat. No.
1606-XLB
Back-of-panel bracket for XLS and XLE power supplies, 20 A and above
1606-XLC
11
12
13
www.ab.com/catalogs
Publication A117-CA001A-EN-P
8-11
Bulletin 1606
Power Supplies
Product Selection/Accessories
1606 Special Modules
0
1
2
3
Input Voltage
Output Power
[W]
Output
Voltage
Output
Current [A]
1836V DC
40
5.1
N/A
N/A
Yes
1606-XLDC40A
1432.4V DC
92
24
3.8
N/A
N/A
1606-XLDC92D
1.02/0.48
Yes
1606-XLSDNET4
91
24
3.8
100240V AC,
110300V DC
192
24
2.13/1.00
Yes
1606-XLSDNET8
100120/200
240V AC
80
2428
3.3
1.50/0.68
No
1606-XLEDNET3
100120/200
240V AC,
160375V DC
60
2.5
1.30/0.70
Yes
1606-XL60DR
100120/200
240V AC,
210375V DC
120
2.60/1.40
Yes
1606-XL120DR
100120/200
240V AC,
240375V DC
240
10
6.00/2.60
Yes
1606-XL240DR
24V DC
720
30
N/A
N/A
1606-XLRED20-30
24V DC
960
40
N/A
N/A
1606-XLRED40
1060V DC
384
16
N/A
N/A
1606-XLPRED
1060V DC
480
20
N/A
N/A
1606-XLSRED
24...28
960
40
N/A
N/A
1606-XLSRED40
24...28
1920
80
N/A
N/A
1606-XLSRED80
2460V DC
480
20
N/A
N/A
1606-XLERED
24
7
8
Input Voltage
Output Voltage
22.530V DC
240
22.5
10
22.530V DC
240
22.5
10
1606-XLS240-UPSC
22.5...30V DC
240
12/22.5
5/10
1606-XLS240-UPSD
22.5...30V DC
240
22.5
10
1606-XLS240-UPSE
2428.8V DC
480
22.527.8
20
1606-XLSBUFFER24
4856V DC
960
4554
10
1606-XLSBUFFER48
Description
Cat. No.
1606-XLSBAT1
1606-XLSBATBR1
1606-XLSBATASSY2
26 Ah/12V Battery
1606-XLSBAT2
11
1606-XLS240-UPS
1606-XLSBATASSY1
7 Ah/12V Battery
10
Cat. No.
Cat. No.
100240V AC,
110300V DC
Steady State
Input Current
120/230 [V
Parallel
AC]
Operation DC OK Relay
1606-XLSBATBR2
12
13
www.ab.com/catalogs
8-12
Publication A117-CA001A-EN-P
Bulletin 1606
Power Supplies
Specifications/Approximate Dimensions
Bulletin 1606-XLS
1606-XLS80E
1606-XLS120E
1606-XLS120EA
1606-XLS180B
1606-XLS240E
1606-XLS240EA
1606-XLS240EC
Output Volts/Watts
2428V/80 W
2428V/120 W
12...15V/180 W
2428V/240 W
100240V AC,
110...300V DC
Operational Range
Hold-up Time
27174 ms
3359 ms
32 ms
27 ms
typ. 90.0%
typ. 92.7%
typ. 91.5%
typ. 91.8%
2428V
2428V
12...15V
2428V
3.4 A (@ 24V)
3.0 A (@ 28V)
5 A (@ 24V)
4.5 A (@ 28V)
15 A
10 A (@ 24V)
9 A (@ 28V)
ReservePower (typ. 4 s)
5.4 A (@ 24V)
5.0 A (@ 28V)
7.5 A (@ 24V)
6.7 A (@ 28V)
22.5 (@12V)
15 A (@ 24V)
13.5 A (@ 28V)
<100 mVPP
<50 mVPP
<50 mVPP
<50 mVPP
Ripple/Noise
Operating Temperature
Range (Tamb)
Dimensions (W x H x D)
Weight
1
2
3
Non-Operating
Temperature Range
MTBF
-40...+85 C
>650 000 hours
32 x 124 x 102 mm
40 x 124 x 117 mm
60 x 124 x 117 mm
60 x 124 x 117 mm
620 g
900 g
420 g
Certifications/Standards1
900 g
1, 2, 3, 5, 6, 7, 9
Special Features
1, 2, 3, 5, 6, 7, 8, 9
1 1) = CE, 2) = UL 508 (cULus LISTED), 3) = UL 1950 (cURus), 4) = CSA C22.2, No. 60950, 5) Safety standards = IEC/EN 60950, EN 50178, 6) EMC standards =
EN 55011 (Class B), EN 55022 (Class B), EN 61000-6-2, 7) EMC standards = EN 61000-3-2 (A14), EN 50081-1, 8) ATEX, 9) GL/ABS
MTBF determined by Siemens norm SN 29500 at full load current and 40 C, 8) ATEX
Indicates ATEX rating
Indicates conformal coating
1606-XLS480E
1606-XLS480EA
1606-XLS480EC
1606-XLS480E-3
1606-XLS480E-3C
1606-XLS480F
1606-XLS480F-3
1606-XLS480G
1606-XLS480G-3
Output Volts/Watts
2428V/480 W
2428V/480 W
48...56V/480 W
48...56V/480 W
36...42V/480 W
36...42V/480 W
100240V AC
/110...300V DC
380480V AC,
600V DC
100240V AC,
110...300V DC
380...480V AC
100240V AC,
110...300V DC
380480V AC,
600V DC
85276V AC,
88375V DC
323552V AC,
450780V DC
85276V AC,
88375V DC
323...552 V AC
85276V AC,
88375V DC
323552V AC,
450780V DC
3251 ms
19 ms
32...51 ms
22 ms
32...51 ms
22 ms
typ. 92.4%
typ. 94.8%
typ. 92.4%
typ. 95.4 %
typ. 92.4%
typ. 94.8%
2428V
2428V
2428V
48...55V
36...42V
36...42V
20 A (@ 24V)
17 A (@ 28V)
20 A (@ 24V)
17.5 A (@ 28V)
20 A (@ 24V)
17 A (@ 28V)
10 A (@ 48V)
13 A (@ 36V)
13.3 A (@ 36V)
ReservePower (typ. 4 s)
30 A (@ 24V)
26 A (@ 28V)
30 A (@ 24V)
26 A (@ 28V)
30 A (@ 24V)
15 A (@ 48V)
20 A (@ 42V)
20 A (@ 42V)
<100 mVPP
<100 mVPP
<100 mVPP
<100 mVPP
<100 mVPP
<100 mVPP
10
11
Operational Range
Hold-up Time
Rated Input Current
Efficiency
Output Voltage
Ripple/Noise
Operating Temperature
Range (Tamb)
-25...+70 C
>60 C with derating
Non-Operating
Temperature Range
-25...+70 C
>60 C with derating
MTBF
Dimensions (W x H x D)
Weight
Certifications/Standards1
84 x 124 x 127 mm
65 x 124 x 127 mm
84 x 124 x 127 mm
65 x 124 x 127 mm
82 x 124 x127 mm
65 x 124 x127 mm
1200 g
870 g
1200 g
870 g
1200 g
870 g
1, 2, 3, 5, 6, 7, 8, 9
1, 2, 3, 5, 6, 7, 9
Special Features
7
8
9
12
ABS/GL/RINA (Marine)
1 1) = CE, 2) = UL 508 (cULus LISTED), 3) = UL 1950 (cURus), 4) = CSA C22.2, No. 60950, 5) Safety standards = IEC/EN 60950, EN 50178, 6) EMC standards =
EN 55011 (Class B), EN 55022 (Class B), EN 61000-6-2, 7) EMC standards = EN 61000-3-2 (A14), EN 50081-1, 8) ATEX, 9) ABS/GL/RINA (Marine)
MTBF determined by Siemens norm SN 29500 at full load current and 40 C
Indicates ATEX rating
Indicates conformal coating
www.ab.com/catalogs
13
Publication A117-CA001A-EN-P
8-13
Bulletin 1606
Power Supplies
Specifications/Approximate Dimensions
Bulletin 1606-XLS
0
1
Output Volts/Watts
2428V/960 W
Operational Range
380...480 V AC
Hold-up Time
32 ms
20 ms
20 ms
4.6 A
1.65 A
1.65 A
typ. 94.6%
typ. 95.2%
typ. 95.4%
24...28V
24...28V
48...54V
40 A (@ 24V)
34 A (@ 28V)
40 A (@ 24V)
34.3 A (@ 28V)
20 A (@ 48V)
17.8 A (@ 54V)
ReservePower (typ. 4 s)
60 A (@ 24V)
51 A (@ 28V)
60 A (@ 24V)
51 A (@ 28V)
30 A (@ 48V)
26.7 A (@ 54V)
<100 mVPP
<100 mVPP
<100 mVPP
Ripple/Noise
Operating Temperature
Range (Tamb)
-25 C...+70 C
Non-Operating
Temperature Range
-40 C...+85 C
Dimensions (W x H x D)
1606-XLS960F-3
2428V/960 W
Output Voltage
1606-XLS960E-3
2428V/960 W
Efficiency
1606-XLS960EE
1800 g
1500 g
1800 g
Weight
Certifications/Standards1
1, 2, 3, 4, 5, 6, 7, 9
Special Features
1 1) = CE, 2) = UL 508 (cULus LISTED), 3) = UL 1950 (cURus), 4) = CSA C22.2, No. 60950, 5) Safety standards = IEC/EN 60950, EN 50178, 6) EMC standards =
EN 55011 (Class B), EN 55022 (Class B), EN 61000-6-2, 7) EMC standards = EN 61000-3-2 (A14), EN 50081-1, 9) ABS/GL/RINA (Marine)
MTBF determined by Siemens norm SN 29500 at full load current and 40 C
1606XLE80E
1606XLE120E
1606XLE120EC
1606XLE120EE
1606XLE120EN
1606XLE240E
1606XLE240EE
1606XLE240EN
1606XLE240EP
1606XLE240F
Output Volts/
Watts
24V...28V/
80 W
24V...28V/
120 W
24V...28V/
120 W
24V...28V/
120 W
24V...28V/
240 W
24V...28V/
240 W
24V...28V/
240 W
24V...28V/
240 W
48V...52V/
240 W
100...120/
200...240
100...120/
200...240
200...240
100...120
100...120/
200...240
200...240
100...120
100...120/200...240
Operational Range
[V AC]
90...132/
180...264
90...132
180...264
90...132
90...132/
180...264
180...264
90...132
90...132/180...264
Hold-up Time
>60 ms
(120V)
>244 ms
(240V)
>80 ms
(120V)
>78 ms
(240V)
>80 ms
(120V)
>78 ms
(240V)
>46 ms
(120V)
>42 ms
(240V)
>45 ms
(240V)
>46 ms
(120V)
1.24 A (100V
AC)
0.68 A (240V
AC)
2.6 A (100V
AC)
1.3 A (240V
AC)
2.6 A
1.4 A
5A
(100V AC)
2.5 A
(240V AC)
2.7 A
5A
typ. 90%
typ. 90%
typ. 90%
typ. 90.2%
typ. 91%
3.3 A @ 24V
2.9 A @ 28V
5 A @ 24V
4.3 A @ 28V
6
7
8
9
Efficiency
Output Voltage
10
5 A @ 24V
5 A @ 24V
Non-Operating
Temperature Range
Weight
typ. 92%
10 A
5 A @ 48V
4.6 A @ 52V
800 g
700 g
48...52V
10 A @ 24V
8.6 A @ 28V
10 A @ 24V
10 A @ 24V
-40...+85 C
>700 000 hours
32 x 124 x
102 mm
430 g
32 x 124 x 117 mm
500 g
500 g
Certifications/Standards1
Special Features
typ. 91%
MTBF
12
typ. 90.8 %
<50 mVPP
Ripple/Noise
Dimensions (W x H x D)
>46ms
(120V)
>42ms
(240V)
<5.0 A
<1.3 A
(115V)/
(115V)/
<2.3 A (230V) <0.7 A (230V)
24...28V
Operating Temperature
Range (Tamb)
11
typ. 91.6 %
>46ms
(120V)
>42ms
(240V)
60 x 124 x 117 mm
500 g
700 g
700 g
700 g
1, 2, 3, 4, 5, 6, 7, 9
NEC Class 2
1 1) = CE, 2) = UL 508 (cULus LISTED), 3) = UL 1950 (cURus), 4) = CSA C22.2, No. 60950, 5) Safety standards = IEC/EN 60950, EN 50178, 6) EMC standards =
13
EN 55011 (Class B), EN 55022 (Class B), EN 61000-6-2, 7) EMC standards = EN 61000-3-2 (A14), EN 50081-1, 9) ABS/GL/RINA (Marine)
MTBF determined by Siemens norm SN 29500 at full load current and 40 C.
Indicates conformal coating.
www.ab.com/catalogs
8-14
Publication A117-CA001A-EN-P
Bulletin 1606
Power Supplies
Specifications/Approximate Dimensions
Bulletin 1606-XLP
Output Volts/Watts
1606-XLP15A
1606-XLP15B
1606-XLP15E
1606-XLP25A
5...5.5V/15 W
12...15V/15 W
24...28V/15 W
5...5.5V/25 W
Operational Range
Hold-up Time
85...264V AC
>168 ms (230V AC)
>45 ms (100V AC)
typ. >83%
typ. >88%
typ. >80%
Output Voltage
5...5.5V
5.1V preset
12...15V
24...28V
5...5.5V
5.1V preset
5 A (at 5.1V),
4.5 A (at 5.5V)
Ripple/Noise
3A
1.0...1.3 A
0.54...0.63 A
<50 mVpp
<75 mVpp
<50 mVpp
Operating Temperature
Range (Tamb)
MTBF
<50 mVpp
-10...+70 C
>60 C: 0.5 W/K derating
Non-Operating
Temperature Range
2 686 000 hours
22.5 x 75 x 91 mm
45 x 75 x 91 mm
130 g
240 g
Weight
Certifications/Standards1
1, 2, 4, 5, 7, 9
Special Features
1 1) = CE, 2) = UL 508 (cULus LISTED), 3) = UL 1950 (cURus), 4) = CSA C22.2, No. 60950, 5) Safety standards = IEC/EN 60950, EN 50178, 6) EMC standards =
EN 55011 (Class B), EN 55022 (Class B), EN 61000-6-2, 7) EMC standards = EN 61000-3-2 (A14), EN 50081-1, 9) ABS/GL/RINA (Marine)
MTBF determined by Siemens norm SN 29500 at full load current and 40 C
1606-XLP30B
1606-XLP30E
1606-XLP30EQ
1606-XLP36C
1606-XLP50B
10...12V/30 W
24...28V/30 W
24...28V/30 W
12V/15V/36 W
12...15V/50 W
Hold-up Time
typ. 84%
typ. 87.5%
typ. 88.5%
typ. 86%
typ. 90%
12...15V
15V preset (with jumper)
12...15V adjustable
(without jumper)
10...12V
12V preset (with jumper),
10...12V adjustable
(without jumper)
24...28V
24.5V preset
24...28V
3 A (@ 10V),
2.5 A (@ 12V)
1.3 A (@ 24.5V),
1 A (@ 28V)
1.3 A (@ 24V),
1 A (@ 28V)
0...2.8 A (@ +12V),
0...1.4 A (@ -12V)
0...2.4 A (@ +15V),
0...1.4 A @ (-15V)
4.2 A (@ 12V),
3.4 A (@ 15V)
<10 mVpp
<50 mVpp
<50 mVpp
<50 mVpp
<100mVpp
Operating Temperature
Range (Tamb)
-10...+70 C
-10...+70 C
-10...+70 C
-10...+70 C
>60 C: 0.6 W/K derating >60 C: 0.5 W/K derating >60 C: 0.8 W/K derating > 60 C: 1 W/K derating
-10...+70 C
>60 C: 1 W/K derating
Non-Operating
Temperature Range
-10...+70 C
-10...+70 C
-10...+70 C
-10...+70 C
>60 C: 0.6 W/K derating >60 C: 0.5 W/K derating >60 C: 0.5 W/K derating > 60 C: 1 W/K derating
-10...+70 C
>60 C: 1 W/K derating
45 x 75 x 91 mm
22.5 x 75 x 91 mm
45 x 75 x 91 mm
45 x 75 x 91 mm
250 g
230 g
140 g
240 g
260 g
MTBF
Dimensions (W x H x D)
Weight
Certifications/Standards1
Special Features
85...264V AC
>170 ms (230V AC)
>18 ms (100V AC)
Output Voltage
Operational Range
Efficiency
-40...+85 C
Dimensions (W x H x D)
Output Volts/Watts
Efficiency
Output voltage
adjustable:
DC 12...15V without
jumper or
DC 15V with jumper;
NEC Class 2 power
supply;
Class 1 Div. 2
ABS/GL/RINA (Marine)
1 1) = CE, 2) = UL 508 (cULus LISTED), 3) = UL 1950 (cURus), 4) = CSA C22.2, No. 60950, 5) Safety standards = IEC/EN 60950, EN 50178, 6) EMC standards =
EN 55011 (Class B), EN 55022 (Class B), EN 61000-6-2, 7) EMC standards = EN 61000-3-2 (A14), EN 50081-1, 9) ABS/GL/RINA (Marine)
MTBF determined by Siemens norm SN 29500 at full load current and 40 C
www.ab.com/catalogs
Publication A117-CA001A-EN-P
8
9
10
11
1, 2, 4, 5, 7, 9
Output voltage
adjustable:
DC 12V without jumper
NEC Class 2 power
NEC Class 2 power
or
supply; Class 1 Div. 2;
supply; Class 1 Div. 2;
DC 15V with jumper;
Semi F47, ABS/GL/RINA Semi F47, ABS/GL/RINA
NEC Class 2 power
(Marine)
(Marine)
supply;
Class 1 Div. 2;
ABS/GL/RINA (Marine)
8-15
12
13
Bulletin 1606
Power Supplies
Specifications/Approximate Dimensions
Bulletin 1606-XLP
1606-XLP50E
Output Volts/Watts
1606-XLP50EZ
24...28V/50 W
Hold-up Time
typ. 88.5%
typ. 90%
24...28V
24.5V preset
48...56V
48V preset
24...28V
2.1 A (@ 24.5V),
1.8 A (@ 28V)
1.05 A (@ 48V),
0.9 A (@ 56V)
2.5 A (@ 24V),
2.1 A (@ 28V)
<200 mVpp
<50 mVpp
Output Voltage
Rated Output Current
<50 mVpp
Ripple/Noise
Operating Temperature
Range (Tamb)
Dimensions (W x H x D)
Weight
6
7
Output Volts/Watts
1606-XLP60BQ
1606-XLP60BQT
1606-XLP72E
1606-XLP90B
1606-XLP90E-2
12...15V/54 W
12...15V/54 W
24...28V/72 W
12...15V/90 W
24...28V/90 W
100...240V
100...240V
100...120/220...240V AC
manual select;
220...375V DC
100...120/220...240V AC;
220...375V DC
2, 380...480V AC
85...264V AC
85...264V AC
85...132/184...264V AC
323..552V AC
<1.9 A
<0.42 A (400V)
<0.36 A (480V)
typ. 87.2 %
typ. 87.6 %
typ. 89%
typ. 88.5%
typ. 89%
12...15V
12...15V
24...28V
24.5V preset (at 2.9 A)
12...15V
Preset at 12V
24...28V
Preset at 24.5V
4.5 A (@ 12V),
3.6 A (@ 15V)
4.5 A (@ 12V),
3.6 A (@ 15V)
3 A (@ 24V),
2.6 A (@ 28V)
7.5 A (@ 12V),
6 A (@ 15V)
3.75 A (@ 24V),
3.2 A (@ 28V)
<50 mVpp
<50 mVpp
<50 mVpp
<50 mVpp
<50 mVpp
-10...+70 C
60...70 C: 1.4 W/C
derating
-40...+70 C
60...70 C: 1.4 W/C
derating
-10...+70 C
>60 C: 1.5 W/K derating
-10...+70 C
>60 C: 1 W/K derating
-10...+70 C
>60 C: 2 W/K derating
Efficiency
Ripple/Noise
Non-Operating
Temperature Range
MTBF
Dimensions (W x H x D)
Weight
Certifications/Standards1
Special Features
13
Operating Temperature
Range (Tamb)
12
Hold-up Time
11
Removeable
Terminations;
NEC Class 2 power
supply;
ABS/GL/RINA (Marine);
Class 1 Div. 2
Output Voltage
10
250 g
1, 2, 3, 4, 5, 6
EN 55011 (Class B), EN 55022 (Class B), EN 61000-6-2, 7) EMC standards = EN 61000-3-2 (A14), EN 50081-1, 9)ABS/GL/RINA (Marine)
MTBF determined by Siemens norm SN 29500 at full load current and 40 C
Operational Range
240 g
1, 2, 3, 4, 5, 6, 9
1 1) = CE, 2) = UL 508 (cULus LISTED), 3) = UL 1950 (cURus), 4) = CSA C22.2, No. 60950, 5) Safety standards = IEC/EN 60950, EN 50178, 6) EMC standards =
Certifications/Standards1
Special Features
-40...+70 C
>60 C: 1 W/K derating
-40...+85 C
MTBF
typ. 88%
-10...+70 C
>60 C: 1 W/K derating
Non-Operating
Temperature Range
Efficiency
1606-XLP60EQT
24...28V/60 W
85...264V AC
>171 ms (230V AC)
>17 ms (100V AC)
1606-XLP60EQ
Operational Range
1606-XLP50F
48...56V/50 W
>52 ms (400V)
>93 ms (480V)
-40...+85 C
45 x 75 x 91 mm
45 x 75 x 91 mm
45 x 75 x 91 mm
73 x 75 x 103 mm
73 x 75 x 103 mm
250 g
250 g
260 g
360 g
360 g
1, 2, 3, 4, 5, 6
1, 2, 3, 4, 5, 6
1, 2, 3, 4, 5, 6, 9
1, 2, 3, 4, 5, 6, 7, 9
1, 2, 3, 4, 5, 6, 7, 9
1 1) = CE, 2) = UL 508 (cULus LISTED), 3) = UL 1950 (cURus), 4) = CSA C22.2, No. 60950, 5) Safety standards = IEC/EN 60950, EN 50178, 6) EMC standards =
EN 55011 (Class B), EN 55022 (Class B), EN 61000-6-2, 7) EMC standards = EN 61000-3-2 (A14), EN 50081-1, 9)ABS/GL/RINA (Marine)
MTBF determined by Siemens norm SN 29500 at full load current and 40 C
www.ab.com/catalogs
8-16
Publication A117-CA001A-EN-P
Bulletin 1606
Power Supplies
Specifications/Approximate Dimensions
Bulletin 1606-XLP
Output Volts/Watts
1606-XLP95E
1606-XLP100E
1606-XLP100F
1606-XLP100E-2
24...28V/95 W
24...28V/100 W
48...56V/100 W
24...28V/100 W
Operational Range
323..552V AC
>48 ms (400V)
>85 ms (480V)
2, 380...480V AC
85...132/184...264V AC
Hold-up Time
<0.46 A (400V)
<0.40 A (480V)
typ. 90%
typ. 91%
typ. 89%
24...28V
24.5V preset
48...56V
48V preset
24...28V
Preset at 24.5V
3.9 A (@ 24.5V),
3.2 A (@ 28V)
4.2 A (@ 24.5V),
3.6 A (@ 28V)
2.1 A (@ 48V),
1.8 A (@ 56V)
4.2 A (@ 24V),
3.6 A (@ 28V)
<50 mVpp
<50 mVpp
<50 mVpp
<50 mVpp
Operating Temperature
Range (Tamb)
2
3
-10...+70 C
>60 C: 2 W/K derating
Non-Operating Temperature
Range
-40...+85 C
MTBF
Dimensions (W x H x D)
73 x 75 x 103 mm
360 g
Weight
Certifications/Standards1
Special Features
1, 2, 3, 4, 5, 6, 7
1, 2, 3, 5, 6, 9
1, 2, 3, 5, 6, 9
Single/parallel operation
(inclined characteristic) select
on front panel;
ABS/GL/RINA (Marine);
Class 1 Div. 2;
Semi F47
1 1) = CE, 2) = UL 508 (cULus LISTED), 3) = UL 1950 (cURus), 4) = CSA C22.2, No. 60950, 5) Safety standards = IEC/EN 60950, EN 50178, 6) EMC standards =
EN 55011 (Class B), EN 55022 (Class B), EN 61000-6-2, 7) EMC standards = EN 61000-3-2 (A14), EN 50081-1, 9)ABS/GL/RINA (Marine)
MTBF determined by Siemens norm SN 29500 at full load current and 40 C
Shut Down
DC ok
Thermal Alarm
Current Monitor
Current Balance
Signal-GND
5
6
7
8
9
10
1 k
5V signal
1 k
Si gn al -GN D
5 V/0 .5 W
11
12
13
www.ab.com/catalogs
Publication A117-CA001A-EN-P
8-17
Bulletin 1606
Power Supplies
Specifications/Approximate Dimensions
Bulletin 1606 Special Modules
0
Output Volts/Watts
1606-XLSDNET8
24V/91 W
24V/192 W
1606-XLEDNET3
24V...28V/80 W
18...36V DC
24V DC
Operational Range
16...40V DC
14...32.4V DC
85264V AC
88360V DC
85276 V AC
88375 V DC
90...132V AC/180...264V
AC
Hold-up Time
18...36V DC
18...36V DC
43 ms (120V AC)
77 ms (240V AC)
38 ms (120V AC)
41 ms (240V AC)
>60 ms (120V)
>244 ms (240V)
<2.9 A
<5.5 A
Efficiency
AC 100240V
110...300V
DC 100...120V AC/200...240
V AC
typ. 82%
typ. 90.3%
typ. 92.4%
typ. 92.7%
Output Voltage
5.1V
24V
24V
24V
24...28V
8A
3.8 A
3.8 A
8A
3.3 A @ 24V
2.9 A @ 28V
Ripple/Noise
Operating Temperature
Range (Tamb)
MTBF
Dimensions (W x H x D)
Weight
Certifications/Standards1
1606-XLSDNET4
24V/92 W
Non-Operating
Temperature Range
1606-XLDC92D
24V/40 W
100240V AC;
110...300V DC
1606-XLDC40A
<50 mVPP
<50 mVPP
< 50 mVpp
< 50 mVpp
<50 mVPP
0...+70 C
>60 C with derating
-25...+70 C
>60 C with derating
-25...+70 C
>60 C with derating
-25...+70 C
>60 C with derating
-25...+85 C
-40...+85 C
-40...+85 C
-25...+70 C
>60 C with derating
-40...+85 C
49 x 124 x 102 mm
32 x 124 x 102 mm
40 x 124 x 117 mm
60 x 124 x 117 mm
32 x 124 x 102 mm
470 g
410 g
620 g
900 g
430 g
1, 2, 3, 5, 6, 7
1, 2, 3, 5, 6, 7
1, 2, 3, 5, 6, 7
1, 2, 3, 4, 5, 6, 7
Special Features
1 1) = CE, 2) = UL 508 (cULus LISTED), 3) = UL 1950 (cURus), 4) = CSA C22.2, No. 60950, 5) Safety standards = IEC/EN 60950, EN 50178, 6) EMC standards =
EN 55011 (Class B), EN 55022 (Class B), EN 61000-6-2, 7) EMC standards = EN 61000-3-2 (A14), EN 50081-1
MTBF determined by Siemens norm SN 29500 at full load current and 40 C
7
Output Volts/Watts
Input Voltage (47...63 Hz)
Operational Range
Hold-up Time
Rated Input Current
Efficiency
Output Voltage
9
10
N+1 Redundancy
1606-XL120DR
1606-XL240DR
24V/60 W
24V/120 W
24V/240 W
85...132/176...264V AC
typ. 86.5%
typ. 89%
typ. 89%
24V
24V
24V
2.5 A
5A
10 A
6A
12 A
Ripple/Noise
<30 mVPP
<30 mVPP
<30 mVPP
Operating Temperature
Range (Tamb)
-10...+70 C
>60 C with derating
-10...+70 C
>60 C with derating
0...+70 C
>60 C with derating
Non-Operating
Temperature Range
-10 C...+70 C
>60 C with derating
-40...+85 C
-40...+85 C
Dimensions (W x H x D)
Weight
Certifications/Standards1
12
N+1 Redundancy
1606-XL60DR
Power Boost
MTBF
11
N+1 Redundancy
Special Features
480.000 hours
390.000 hours
49 x 124 x 102 mm
64 x 124 x 102 mm
470 g
620 g
980 g
1, 2, 3, 5, 6
1, 2, 3, 5, 6, 7
1, 2, 3, 5, 6
1 1) = CE, 2) = UL 508 (cULus LISTED), 3) = UL 1950 (cURus), 4) = CSA C22.2, No. 60950, 5) Safety standards = IEC/EN 60950, EN 50178, 6) EMC standards =
EN 55011 (Class B), EN 55022 (Class B), EN 61000-6-2, 7) EMC standards = EN 61000-3-2 (A14), EN 50081-1
MTBF determined by Siemens norm SN 29500 at full load current and 40 C
13
www.ab.com/catalogs
8-18
Publication A117-CA001A-EN-P
Bulletin 1606
Power Supplies
Specifications/Approximate Dimensions
Bulletin 1606 Redundancy Module
N+1 Redundancy N+1 Redundancy N+1 Redundancy
Output Volts/Watts
Input Voltage (47...63 Hz)
Output Voltage
Rated Output Current
Operating Temperature
Range (Tamb)
Dimensions (W x H x D)
Weight
Certifications/Standards1
Special Features
1606-XLRED40
1606-XLPRED
30 A Dual
redundancy
module
40 A Single
redundancy
module
8 A Dual
redundancy
10 A Dual redundancy
20 A Dual
redundancy
40 A Dual
redundancy
DC 10...60V
DC 10...60V
24...28 V DC
24...28 V DC
10...60V DC
10...60V DC
24...28 V DC
24...28 V DC
Operational Range
Rated Input Current
N+1 Redundancy
1606-XLRED2030
18...36 V DC
1606-XLSRED
1606-XLERED
20...30 A (max.
35 A)
0...40 A (max. 50
A)
Single input: 8 A
max.
Dual input: 16 A
max. total
20...30 A (max.
35 A)
0...40 A (max. 50
A)
0...10 A
0...20 A
0...40 A
0...80 A
-40 C...+70 C
>60 C with
derating
-25 C...+70 C
>60 C with derating
-25 C...+70 C
>60 C with
derating
-25 C...+70 C
>60 C with
derating
36 x 124 x 127
mm
46 x 124 x 127
mm
-10 C...+70 C
48 x 124 x 102
mm
48 x 124 x 117
mm
625 g
646 g
45 x 75 x 91 mm
32 x 124 x 102
mm
32 x 124 x 117
mm
136 g
290 g
350 g
1, 2, 3, 6
1, 2, 3, 6
Single
Dual redundancy
redundancy
module for 2x35
module for 2.5-50
A; N+1
A; N+1
redundancy
redundancy
Redundancy for
DC 10...60V
applications;
ABS/GL/RINA
(Marine);
Class 1 Div. 2
1, 2, 3, 6
Redundancy for
DC 10...60V
applications;
Class 1 Div. 2
Redundancy for
DC 10...60V
applications;
Class 1 Div. 2;
DC OK
1606-XLSRED40 1606-XLSRED80
340 g
440 g
1, 2, 3, 6
1, 2, 3, 6
Redundancy for
DC 24...28V
applications;
Class 1 Div. 2
Redundancy for
DC 24...28V
applications;
Class 1 Div. 2
1
2
3
4
5
1 1) = CE, 2) = UL 508 (cULus LISTED), 3) = UL 1950 (cURus), 4) = CSA C22.2, No. 60950, 5) Safety standards = IEC/EN 60950, EN 50178, 6) EMC standards =
EN 55011 (Class B), EN 55022 (Class B), EN 61000-6-2, 7) EMC standards = EN 61000-3-2 (A14), EN 50081-1
MTBF determined by Siemens norm SN 29500 at full load current and 40 C
6
7
8
9
10
11
12
13
www.ab.com/catalogs
Publication A117-CA001A-EN-P
8-19
Bulletin 1606
Power Supplies
Specifications/Approximate Dimensions
0
1
Bulletin 1606-XLSBUFFER
Buffer Module
Buffer Module
1606-XLSBUFFER 24
1606-XLSBUFFER 48
Output Volts
22.5V DC
45V DC
Input Current
80 mA typ.
600 mA max.
40 mA typ.
500 mA max.
Hold-up Time
200 ms @ 20 A
Output Voltage
2
3
100 ms @ 20 A
Vin -2V: 45V fixed
20 A
20 A
Operating Temperature
Range (Tamb)
-25...+70 C
Non-Operating
Temperature Range
-40...+85 C
Dimensions (W x H x D)
64 x 124 x 102 mm
Weight
64 x 124 x 102 mm
740 g
740 g
Certifications/Standards1
1, 2, 3, 5, 6
Special Features
1 1) = CE, 2) = UL 508 (cULus LISTED), 3) = UL 1950 (cURus), 4) = CSA C22.2, No. 60950, 5) Safety standards = IEC/EN 60950, EN 50178, 6) EMC standards =
EN 55011 (Class B), EN 55022 (Class B), EN 61000-6-2, 7) EMC standards = EN 61000-3-2 (A14), EN 50081-1
Low inrush current
5
Bulletin 1606-XLS UPS
6
7
UPS
UPS
UPS
UPS
1606-XLS240-UPS
1606-XLS240-UPSC
1606-XLS240-UPSD
1606-XLS240-UPSE
22.5V...30V/240 W
22.25V/240 W
22.25V and
12V/240 W
typ. 0.12 A/
max. 1.3 A
typ. 0.12 A/
max. 1.3 A
typ. 0.12 A/
max. 1.3 A
22.5...30V DC
22.5...30V DC
22.5...30V DC
22.5...30V DC
Output Volts/Watts
Operational Range
Hold-up Time
8
9
10
battery dependent
Output Voltage
22.4V
22.25V
22.25V
22.25V
10 A
10 A
10 A
10 A
Power Boost
15 A
15 A
15 A
15 A
Operating Temperature
Range (Tamb)
-25...+60 C
-25...+40 C
Non-Operating
Temperature Range
-40...+85 C
-20...+50 C
MTBF
Dimensions (W x H x D)
49 x 124 x 117
49 x 124 x 117
49 x 124 x 117
530 g
2850 g
650 g
545 g
Weight
Certifications/Standards1
1, 2, 3, 5, 6
Special Features
1 1) = CE, 2) = UL 508 (cULus LISTED), 3) = UL 1950 (cURus), 4) = CSA C22.2, No. 60950, 5) Safety standards = IEC/EN 60950, EN 50178, 6) EMC standards =
11
EN 55011 (Class B), EN 55022 (Class B), EN 61000-6-2, 7) EMC standards = EN 61000-3-2 (A14), EN 50081-1
MTBF determined by Siemens norm SN 29500 at full load current and 40 C
12
13
www.ab.com/catalogs
8-20
Publication A117-CA001A-EN-P
Bulletin 1606
Power Supplies
Approximate Dimensions
Approximate Dimensions
Approximate dimensions are shown in millimeters (in.) unless otherwise indicated. Dimensions are not to be used for manufacturing purposes.
A
B
C
5.1
133
+ + - -
48.6
OUTPUT
143
133
3.15
143
INPUT
N L PE
7.5
mm
1606-XLS80E
1606-XLS120E
1606-XLS240E
1606-XLS480E-3
1606-XLSRED
A
32
40
60
65
32
B
4.8
5.3
5.8
6.3
4.8
C
22.5
29.5
48.5
40
22.5
3
4
5
6
7
8
9
10
11
12
13
www.ab.com/catalogs
Publication A117-CA001A-EN-P
8-21
Bulletin 1606
Power Supplies
Redundancy Capabilities
1606-XL Redundancy Capabilities
The 1606-XL family has two cost effective methods for providing redundancy to applications that are critical and can not risk failure.
1
XL60DR
or
XL120DR
2
3
4
XL60DR
or
XL120DR
5
The 1606-XL60DR, XL120DR and XL240DR are enhanced versions of the standard power supplies.
Each device has internal diodes which provide isolation against DC bus problems corrupting working supplies.
Provides "DC OK" output relay to allow remote monitoring of DC power status.
Utilizes pluggable terminals for easy installation.
7
1606-XLRED20-30 and 1606-XLRED40 Redundancy Modules
GND +24V
GND +24V
XL480 or XL720
10
11
XL480 or XL720
12
13
www.ab.com/catalogs
8-22
Publication A117-CA001A-EN-P
Bulletin 1606
Power Supplies
Functions
Extensive Diagnostic & Monitoring Functions
Protective Features:
Wrong battery voltage (24V instead of 12V)
Wrong battery polarity
Too high ambient temperature
Output overload or output short-circuit
E - Signal contacts:
Ready (contact 1-2):
Contact is closed when battery is charged
more than 85%, no wiring failure is
recognized, input voltage is sufficient, and
inhibit signal is not active.
Buffering (contact 3-4):
Contact is closed when unit is buffering.
Replace battery (contact 5-6):
Contact is closed when input voltage is
sufficient and battery quality test (SCH
test) indicates a negative result, three
times in a row.
A
B
C
D
2
3
4
5
6
7
8
9
10
11
12
13
www.ab.com/catalogs
Publication A117-CA001A-EN-P
8-23
Bulletin 1609
0
1
Bulletin
Output Power
1609-S Industrial
1609-P Commercial
1609-U Industrial
1609-U Commercial
350VA/280 W
3000VA
500VA/325 W
750VA/500 W
1000VA/670 W
1500VA/980 W
Efficiency
96%
Output Voltage/
Secondary Voltage
Rated Output Current
120, 208/230V AC
Operating Temperature
Range
86%
Product Selection
120V AC
1748 A
4.12 A
040 C
040 C
050 C
040 C
-20+60 C
UL, CSA, CE
UL, CSA
UL 1778
FCC Part 15, Class A
Page 8-25
Page 8-32
Page 8-28
5
6
7
8
9
10
11
12
13
www.ab.com/catalogs
8-24
9598%
2.9 A
Certifications
Standards Compliance
96%
120, 208/230V AC
Non-Operating
Temperature Range
120V AC
Publication A117-CA001A-EN-P
Page 8-36
Bulletin 1609-S
Table of Contents
0
1
2
Standards Compliance
Certifications
UL 1778
CE
CSA C22.2, No. 107
FCC
1609 S
350
Output Voltage
Battery Type
Code
Description
Code
Description
Code
Description
Code
Description
350
350VA (280 W)
120V AC
40 C Battery
208/230V AC
5
6
Product Selection
Accessories
Output Power
Input Voltage
Cat. No.
Description
Output Power
Cat. No.
350VA (280 W)
120V AC
1609-S350NS
40 C replacement battery
500VA (325 W)
1609-500SBAT
350VA (280 W)
208/230V AC
1609-S350ES
1609-RSC
1609-SDK1
1609-SDC1
7
8
9
10
11
12
13
www.ab.com/catalogs
Publication A117-CA001A-EN-P
8-25
Bulletin 1609-S
Wiring
0
Input
Nominal Voltage
120V
208/230V
81143V
160287V
75153V
150300V
Nominal Current
2.9 A
1.5 A
Capacity
350VA/280 W
Frequency
4763 Hz
PFC
Wiring
2
On Line Output
3
4
5
Battery Pack
6
7
8
Nominal Voltage
120V
208/230V
106127V
208253V
97136V
196265V
Overload Protection
Efficiency
On Battery Output
Surge Protection
Per EN50091-2
Frequency
THD
Voltage Regulation
Crest Factor
2.5:1
Efficiency
Overload Protection
Overload indication and shutdown @ 107% of rate load or electronic current limit and
shutdown under short circuit condition
Run Time
Type
Voltage
24V
Charger
Recharge Time
Lifetime
35 years @ 25 C ambient
Lifetime cut in half for every 10 C above 25 C
Temperature
Altitude
10 000 ft (operating)
Humidity
Heat Output
Audible Noise
Environment
Communication
Serial
Options
Status LEDs
On line (green)
AVR low line (yellow)
AVR high line (yellow)
On battery (yellow)
Overload and fault (red)
Bad battery (red)
Load percentage of full rating bar graph (green)
Battery state of charge bar graph (green)
Measured input voltage indicated by load bar graph when recessed switch is held
Control Buttons
Audible Alarms
10
1609-S350ES
11
Wiring of the UPS should be performed by a qualified electrician. Use appropriate size wires.
In 230V AC applications, the UPS must be protected with a circuit breaker that complies with European standards for
branch rated protection per the country of installation.
In 208V AC applications, the UPS must be protected by a dual-pole, 10 A branch rated, UL 489 circuit breaker.
The 120V AC 1609-S350NS has supplementary circuit breaker protection. The unit should be protected by a singlepole, 15 A branch rated, UL 489 circuit breaker.
Allen-Bradley part number 1492-MCAA115 is suggested.
The branch circuit breaker must be off prior to wiring the unit.
12
13
www.ab.com/catalogs
8-26
Publication A117-CA001A-EN-P
Bulletin 1609-S
0
1
(6.3)
2
(1.0)
(6.1)
(6.1)
3
4
(0.4)
(5.9)
(0.4)
(14.2)
5
(6.9)
6
7
8
9
1609-S350NS
13.15 (29)
1609-S350ES
13.15 (29)
10
11
12
13
www.ab.com/catalogs
Publication A117-CA001A-EN-P
8-27
Bulletin 1609-U
0
1
Table of Contents
2
3
Standards Compliance
Certifications
UL 1778
CE
CSA C22.2, No. 107
FCC
Overview
4
5
The Bulletin 1609-U has multiple options for remote management. The device is shipped with a DB9 serial cable for serial communication.
The product can be configured with the optional 1609-NMC Network Management Card for Ethernet communications. The serial connection
utilizes the APC PowerChute software, the 1609-NMC has an integrated web browser tool. The Network Management Tools allow the user
to:
Log data
Fault notification
Customize output relays
Monitor temperature
Operating system shutdown
Can be viewed through RSView with
generic SNMP/OPC server
6
7
8
9
10
11
12
13
www.ab.com/catalogs
8-28
Publication A117-CA001A-EN-P
Bulletin 1609-U
1609 U
500
Input/Output Voltage
Network Management
Code
Description
Code
Description
Code
Description
115V AC
NMC included
208/230V AC
b
Description
500
500VA (325 W)
Special Functions
Code
Description
Standard Battery
3
4
Product Selection
Cat. No.
Output Power
Input Voltage
Operating Temperature
120V AC
500VA (325 W)
208/230V AC
Without Network
Management Card
040 C
1609-U500NS
1609-U500NSC
050 C
1609-U500NH
1609-U500NHC
040 C
1609-U500ES
1609-U500ESC
050 C
1609-U500EH
1609-U500EHC
5
6
Accessories
Description
Output Power
Cat. No.
40 C replacement battery
500VA (325 W)
1609-500SBAT
50 C replacement battery
500VA (325 W)
1609-500HBAT
1609-NMC
1609-RSC
7
8
9
10
11
12
13
www.ab.com/catalogs
Publication A117-CA001A-EN-P
8-29
Bulletin 1609-U
1609-U500N . . .
1609-U500E . . .
120V
230V
Capacity
Output
3
4
On Line
On Battery
Efficiency
5
Protection
81143V
160287V
75153V
150300V
Current nom.
4.12 A
2.20 A
Capacity Frequency
4763 Hz
PFC
V nom.
500VA (325 W)
Environment
10
Communication
106127V
208253V
97136V
196265V
In volts AC
Frequency
Typical
THD
Typical
Crest Factor
3:1
On Battery
77%
On Line
96%
Surge
EN50091-2
Overload
Thermal Protection
None
N/A
EMC
FCC (Class A)
EN50091-2 (Class A)
Markings
Type
11
208/230V
Run Time
Battery Pack
Auto-adjusting
120V
Capacity
Safety
500VA (325 W)
Bypass
Regulatory
Input
Notes
Voltage
24V
Charger
Recharge Time
Lifetime
24 years @ 25 C ambient
Temperature
Altitude
10 000 ft (operating)
Humidity
Heat Output
Audible Noise
Typical
DB9
Dry Contact
EPO
Network
Notes
208V AC applications: The 1609-U500E ships ready for 230V AC sources. When operating the UPS in 208V AC applications, the UPS low
transfer voltage settings are adjusted through the PowerChute software or the Network Management Card.
Refer to the PowerChute User Guide or the Network Management Card instructions for details.
12
Wiring of the UPS should be performed by a qualified electrician. Use appropriate size wires.
In 230V AC applications, the UPS must be protected with a circuit breaker that complies with
European standards for branch rated protection per the country of installation.
In 208V AC applications, the UPS must be protected by a dual-pole, 10 A branch rated,
UL 489 circuit breaker.
The 120V AC 1609-U500N has supplementary circuit breaker protection. The unit should be
protected by a single-pole, 15 A branch rated, UL 489 circuit breaker.
Allen-Bradley part number 1492-MCAA115 is suggested.
The branch circuit breaker must be off prior to wiring the unit.
13
www.ab.com/catalogs
8-30
Publication A117-CA001A-EN-P
Bulletin 1609-U
0
1
2
(6.3)
3
(1.0)
(6.1)
(6.1)
4
5
(0.4)
(0.4)
(5.9)
(14.2)
6
7
(6.9)
8
9
Input Voltage
120V AC
500VA (325 W)
208/230V AC
Cat. No.
Without Network
Management Card
1609-U500NS
14.5 (31.9)
1609-U500NSC
15 (33)
1609-U500NH
13.4 (29.5)
1609-U500NHC
13.9 (30.6)
1609-U500ES
14.5 (31.9)
1609-U500ESC
15 (33)
1609-U500EH
13.4 (29.5)
1609-U500EHC
13.9 (30.6)
10
11
12
13
www.ab.com/catalogs
Publication A117-CA001A-EN-P
8-31
Bulletin 1609-P
1
2
Standards Compliance
Certifications
UL 1778
CE
CSA C22.2, No. 107
FCC
Table of Contents
The Bulletin 1609-P has multiple options for remote management. Please see page 8-28 for details.
1609 P
5
6
3000
Input/Output Voltage
Code
Description
Code
Description
Code
3000
3000VA (2100 W)
Description
120V AC
5000
5000VA (3500 W)
208/230V AC
8000
8000VA (6400 W)
230V AC
10000
10000VA (8000 W)
7
Product Selection
Accessories
Output Power
Input Voltage
Cat. No.
3000VA (2100 W)
120V AC
1609-P3000N
3000VA (2100 W)
230V AC
1609-P3000A
Description
Cat. No.
1609-NMC
5000VA (3500 W)
208/230V AC
1609-P5000E
1609-RSC
8000VA (6400 W)
208/230V AC
1609-P8000E
Replacement battery
1609-PBAT
10000VA (8000 W)
208/230V AC
1609-P10000E
Rail kit
1609-PRK1
1609-HDK1
1609-PSB1
10
11
12
13
www.ab.com/catalogs
8-32
1609-PXBP
1609-5000CCT
Publication A117-CA001A-EN-P
Bulletin 1609-P
Input
Output
1609-P3000N
1609-P3000A
1609-P5000E
1609-P8000E
1609-P10000E
V nom. (V AC)
120
230
208/230
208/230
208/230
Voltage Range,
default (V AC)
90150V
Current (A)
20 nom., 28 max.
Capacity
160280V
11 nom., 14 max.
3000VA (2100 W)
Protection
39 nom., 48 max.
8000VA (6400 W)
10 000VA (8000 W)
PFC
> 0.95
Protection
N/A
V nom.
120V
Capacity
N/A
Reg.
3000VA (2100 W)
5000VA (3500 W)
+/- 2% static
+/- 5% dynamic
On Battery
86%
On Line
88%
Surge
IEC 1000-4-4
125% : 1 minute, 150% : 30 seconds
Output Short
Safety
EN 61000-3-2
EMC
FCC (Class A)
EN50091-2
Markings
cULus, CSA
CE
cULus, CSA, CE
5
6
Voltage
192V
Charger
24 years @ 25 C ambient
Temperature
Altitude
10 000 ft (operating)
Humidity
Audible Noise
<50 dB @ 1 meter
(full load)
AC Outlets
AC Inlets
NEMA L530
Lifetime
DB9
Indicators and
Controls
2
3
Overload
Recharge Time
Communication
N/A
THD
Type
Rear Panel
10 000VA (8000 W)
N/A
Nominal +/- 3 Hz
Crest Factor
Run Time
Environment
8000VA (6400 W)
Bypass
Battery Pack
Thermal Protection
Regulatory
N/A
Frequency
Efficiency
30 nom., 40 max.
5000VA (3500 W)
Frequency
Protection
On Battery
19 nom., 24 max.
1040 BTU/hour
1536 BTU/hour
2216 BTU/hour
EPO
Network
Via Network Management Card (1609-NMC, provided as standard with units >3 KVA)
LED Status
On-line, In Bypass Mode, On Battery, Overload and Replace Battery, Fault, Bar graph for Load, Bar graph for
Battery Fuel Gauge, Bar graph for Measured Input Voltage when recessed switch is held
10
Control
Audible
On Battery: 4 short beeps repeats about 20 seconds (mutable), Low Battery: persistent 0.5 second beep every 1
second (mutable), In Bypass: continuous beeping, Failure: continuous tone, Replace Battery: occasional on/off
change - single beep
Wiring of the UPS should be performed by a qualified electrician. Use appropriate size wires.
In 230V AC applications, the UPS must be protected with a circuit breaker that complies with European standards for
branch rated protection per the country of installation.
In 208V AC applications, the UPS must be protected by a dual-pole, 10 A branch rated, UL 489 circuit breaker.
The 120V AC 1609-P3000N has supplementary circuit breaker protection. The unit should be protected by a singlepole, 15 A branch rated, UL 489 circuit breaker.
Allen-Bradley part number 1492-MCAA115 is suggested.
The branch circuit breaker must be off prior to wiring the unit.
www.ab.com/catalogs
Publication A117-CA001A-EN-P
8-33
11
12
13
Bulletin 1609-P
208V AC applications: The 1609-P5000E, 1609-P8000E, and 1609-P10000E, ship ready for 230V AC sources. When operating one of these in
208V AC applications, the UPS low transfer voltage settings are adjusted through the PowerChute software or the Network Management
Card.
Refer to the PowerChute User Guide or the Network Management Card instructions for details.
Approximate Dimensions
Approximate dimensions are shown in millimeters (in.) unless otherwise indicated. Dimensions are not to be used for manufacturing purposes.
(5.1)
(25.3)
2
3
(17.4)
4
5
6
(10.3)
(25.3)
7
(17.4)
8
9
10
11
12
Input
Voltage
Cat. No.
3000VA
(2100 W)
120V AC
1609-P3000N
63.5 (140)
3000VA
(2100 W)
230V AC
1609-P3000A
63.5 (140)
5000VA
(3500 W)
208/230V
AC
1609-P5000E
63.5 (140)
8000VA
(6400 W)
208/230V
AC
1609-P8000E
128.8 (284)
10000VA
(8000 W)
208/230V
AC
1609-P10000E
128.8 (284)
13
www.ab.com/catalogs
8-34
Publication A117-CA001A-EN-P
Bulletin 1609-P
0
(3.7)
(22.8)
1
(4.8)
2
3
(25.3)
(5.1)
4
(17.4)
5
6
7
(25.3)
(5.1)
8
(17.4)
9
10
Description
Cat. No.
Replacement battery
1609-PBAT
37.2 (82)
1609-PXBP
101.2 (223)
1609-5000CCT
63.5 (140)
1609-PRK1
3.6 (8)
11
Approx. Shipping
Weight
[kg (lb)]
12
13
www.ab.com/catalogs
Publication A117-CA001A-EN-P
8-35
Bulletin 1609-U
0
1
2
3
Standards Compliance
UL 1778
BSMI
CSA C22.2, No. 107
FCC Part 15 Class A
Certifications
UL Listed (File No. E190749,
Guide YEDU)
CSA Certified (File LR1234)
Product Selection
Input Voltage
Operating Temperature
120V AC
040 C
Output Power
Cat. No.
750VA (500 W)
1609-U750N
1000VA (670 W)
1609-U1000N
1500VA (980 W)
1609-U1500N
Accessories
Description
Cat. No.
1609-NMC
1609-RSC
1 The 750, 1000, and 1500 W selections are only available in the 115V AC size (N)
with a standard battery (S). Also if a network management card is desired, it can
not be ordered with the product and must be ordered separately. Contact your
local Rockwell Automation sales office or Allen-Bradley distributor.
Specifications
Electrical Ratings
6
Input
1609-U750N
120V
82144V
75154V
Capacity Frequency
V nom.
Output
10
11
750VA (500 W)
1000VA (670 W)
Frequency
THD
Crest Factor
Protection
up to 5:1
(6) NEMA 5-15R
Surge Rating
540 J
459 J
459 J
Filtering
Full time multi-pole noise filtering: 0.3% IEEE surge let-through, zero clamping response time, meets UL 1449
UL 1778, CSA, BSMI, FCC Part 15 UL 1778, CSA, BSMI, FCC Part 15 UL 1778, CSA, BSMI, FCC Part 15 Class
Class A, UL Listed, VCCI
Class A
A
Type
Environment
12
Communication
3 hours
Temperature
Altitude
Humidity
095%, operating
Heat Output
Audible Noise
55 dB @ 1 meter
41 dB @ 1 meter
45 dB @ 1 meter
Interface Ports
Control Panel
LED status display with load and battery bar graphs and On Line, On Battery, Replace Battery, and Overload
indicators
EPO
optional
Audible Alarm
13
www.ab.com/catalogs
8-36
1500VA (980 W)
Output Connections
Regulatory
Battery Pack
1609-U1500N
120V
Capacity
1609-U1000N
V nom.
Publication A117-CA001A-EN-P
Bulletin 1609-U
0
1
A
2
3
C
B
Output Power
[VA (W)]
Height (A)
Width (B)
4
Depth (C)
750 (500)
157 (6.2)
137 (5.4)
358 (14.1)
14.55 (32)
1000 (670)
216 (8.5)
170 (6.7)
439 (17.3)
22 (48.4)
1500 (980)
216 (8.5)
170 (6.7)
439 (17.3)
27 (59.4)
5
6
7
8
9
10
11
12
13
www.ab.com/catalogs
Publication A117-CA001A-EN-P
8-37
Transformers
Product Overview
Transformers
0
1
Bulletin
Type
3
Features
4
Output Power
5
6
1497A
1497B
1497D
Dual/Multi-tap
RoHS compliant
Single phase
50/60 Hz
Optional Fusing
Dual/Multi-tap
RoHS compliant
Single phase
60 Hz only
Optional Fusing
Indoor/outdoor non-ventilated
enclosure
Single phase
Exceeds requirements of the
Uniform Building Code (UBC)
and California Code Title 24
Copper windings provided for
all transformers rated 2 kVA
and below
Aluminum windings provided
for all transformers rated 2 kVA
and above
NEMA Type 3R rated
enclosures
50/60 HZ or 60 Hz
632000VA
503000VA
503000VA
0.0525 kVA
Input Voltage/
Primary Voltage
208600V
220550 (50 Hz)
120600V
208600V
Output Voltage/
Secondary Voltage
24120V
24230V (50 Hz)
24240V
120240V
Insulation
Certifications
Standards
1497
Control Circuit Transformer
Product Selection
cULus, CE
cULus
cULus
UL, CSA
Page 8-39
Page 8-46
Page 8-53
Page 8-59
8
9
10
11
12
13
www.ab.com/catalogs
8-38
Publication A117-CA001A-EN-P
Bulletin 1497
Table of Contents
632000VA
Single, dual, and multi-tap primary voltages
Single phase
EN 60-529 finger-safe protection
RoHS compliant
0
1
Standards Compliance
UL 5085-1, UL 5085-2
EN61558
Certifications
cULus Listed (File No. E52057;
Guide No. XPTQ, XPTQ7)
CE
1497 A M1 3 N
a
Code
VA Rating
Description [VA]
Code
Primary
Secondary
Code
Block Options
63
M1
240V, 208V
0 Primary, 0 Secondary
80
M2
240V, 208V
0 Primary, 1 Secondary
130
M3
240V, 208V
2 Primary, 0 Secondary
200
M4
2 Primary, 1 Secondary
250
M5
350
500
750
800
1000
1600
2000
5
6
d
Factory Installed Options
Code
Description
No Fusing, No Cover
7
8
1497 A BADX 3 N
a
VA Rating
Code
Description [VA]
Code
Primary
Secondary
Code
Block Options
63
HX
0 Primary, 0 Secondary
80
AX
0 Primary, 1 Secondary
130
2 Primary, 0 Secondary
200
BA1
2 Primary, 1 Secondary
250
350
CX
500
DX
750
JX
SX
JK
800
1000
1600
2000
10
11
d
Factory Installed Options
Code
Description
No Fusing, No Cover
12
1 When the primary voltage code BA is selected and a 120V AC secondary is desired, the secondary voltage code SX should be selected.
13
VA rating codes G, H, or J with primary voltage over 500V have only cULus approval.
Not available for use with primary voltage code BA.
VA rating codes HM are only available with no fuse block option (0).
www.ab.com/catalogs
Publication A117-CA001A-EN-P
8-39
Bulletin 1497
0
1
2
3
192
192
240
660
1225
1490
VA
Inrush
29
29
29
45
69
96
VA
Sealed
Bulletin 500
Selection Process
4
5
6
7
8
1. Determine the total inrush VA of the control circuits from the table
below. Do not neglect the current requirements of indicating lights
and other devices that do not have an inrush VA but are reenergized at the same time as the other components in the
circuit. Their total VA should be added to the total inrush VA.
2. Refer to the table below, Regulation Data Inrush VA. If the
supply circuit voltage (Step 1) is reasonably stable and fluctuates
not more than 5%, refer to the 90% secondary voltage column.
If it fluctuates as much as 10%, refer to the 95% secondary
voltage column. Go down the column selected until at the inrush
VA closest to, but not less than, the inrush VA of the control
circuit.
3. Read to the far left side of the chart. The transformers
continuous nominal VA rating is now selected. The secondary
voltage that will be delivered under inrush conditions will be either
85%, 90%, or 95% of the rated secondary voltage, depending on
the column selected from the table below, Regulation Data
Inrush VA. The total sealed VA of the control circuit must not
exceed the nominal VA rating of the transformer selected from the
table below, Typical Magnetic Motor Starter and Contactor Data
60 Hz, 120 Volt, 3-Pole.
4. Refer to the specification tables on the following pages to select
a transformer according to the required continuous nominal VA,
and primary and secondary voltage combinations.
9
10
11
12
Nominal
VA Rating
85%
90%
95%
Power
Factor
Multiply By
63
347
289
216
100%
0.64
80
338
290
229
90%
0.67
130
907
745
541
80%
0.71
200
1267
1039
754
70%
0.78
250
1394
1116
781
60%
0.82
350
2870
2298
1584
50%
0.91
500
3786
3013
2065
40%
1.00
750
7360
5763
3786
30%
1.11
800
7360
5763
3786
20%
1.29
1000
8837
6785
4329
10%
1.50
1600
14921
11328
7070
2000
20500
14850
9100
13
www.ab.com/catalogs
8-40
Publication A117-CA001A-EN-P
Bulletin 1497
Primary
240V (60 Hz)/220V (50 Hz)
208V
240V/
220V
INPUT
INPUT
Primary
240X480V (60 Hz) or 220X440V (50 Hz)
1
440V or
480V
220V or
240V
OUTPUT
OUTPUT
24V or
120V
24V or
120V/110V
24V or
120V/110V
Continuous VA
Secondary
24V (60 Hz)
Secondary
120V (60 Hz)
Secondary
26V (60 Hz)/
24V (50 Hz)
Secondary
120V (60 Hz)/
110V (50 Hz)
Secondary
26V (60 Hz) or
24V (50 Hz)
Secondary
120V (60 Hz) or
110V (50 Hz)
63
1497-A-HXJX-0-N
1497-A-HXDX-0-N
1497-A-AXJK-0-N
1497-A-AXSX-0-N
1497-A-BAJK-0-N
1497-A-BASX-0-N
80
1497-B-HXJX-0-N
1497-B-HXDX-0-N
1497-B-AXJK-0-N
1497-B-AXSX-0-N
1497-B-BAJK-0-N
1497-B-BASX-0-N
130
1497-C-HXJX-0-N
1497-C-HXDX-0-N
1497-C-AXJK-0-N
1497-C-AXSX-0-N
1497-C-BAJK-0-N
1497-C-BASX-0-N
200
1497-D-HXJX-0-N
1497-D-HXDX-0-N
1497-D-AXJK-0-N
1497-D-AXSX-0-N
1497-D-BAJK-0-N
1497-D-BASX-0-N
250
1497-E-HXJX-0-N
1497-E-HXDX-0-N
1497-E-AXJK-0-N
1497-E-AXSX-0-N
1497-E-BAJK-0-N
1497-E-BASX-0-N
350
1497-F-HXJX-0-N
1497-F-HXDX-0-N
1497-F-AXJK-0-N
1497-F-AXSX-0-N
1497-F-BAJK-0-N
1497-F-BASX-0-N
500
1497-G-HXJX-0-N
1497-G-HXDX-0-N
1497-G-AXJK-0-N
1497-G-AXSX-0-N
1497-G-BAJK-0-N
1497-G-BASX-0-N
750
1497-H-HXJX-0-N
1497-H-HXDX-0-N
1497-H-AXJK-0-N
1497-H-AXSX-0-N
1497-H-BAJK-0-N
1497-H-BASX-0-N
800
1497-J-HXJX-0-N
1497-J-HXDX-0-N
1497-J-AXJK-0-N
1497-J-AXSX-0-N
1497-J-BAJK-0-N
1497-J-BASX-0-N
1000
1497-K-HXJX-0-N
1497-K-HXDX-0-N
1497-K-AXJK-0-N
1497-K-AXSX-0-N
1497-K-BAJK-0-N
1497-K-BASX-0-N
1600
1497-L-HXDX-0-N
1497-L-AXSX-0-N
1497-L-BASX-0-N
2000
1497-M-HXDX-0-N
1497-M-AXSX-0-N
1497-M-BASX-0-N
63
1497-A-HXJX-3-N
With 2-Pole Primary and 1-Pole Secondary Top-Mounted Fuse Block Fuses Not Included
1497-A-HXDX-3-N
1497-A-AXJK-3-N
1497-A-AXSX-3-N
1497-A-BAJK-3-N
1497-A-BASX-3-N
80
1497-B-HXJX-3-N
1497-B-HXDX-3-N
1497-B-AXJK-3-N
1497-B-AXSX-3-N
1497-B-BAJK-3-N
1497-B-BASX-3-N
130
1497-C-HXJX-3-N
1497-C-HXDX-3-N
1497-C-AXJK-3-N
1497-C-AXSX-3-N
1497-C-BAJK-3-N
1497-C-BASX-3-N
200
1497-D-HXJX-3-N
1497-D-HXDX-3-N
1497-D-AXJK-3-N
1497-D-AXSX-3-N
1497-D-BAJK-3-N
1497-D-BASX-3-N
250
1497-E-HXJX-3-N
1497-E-HXDX-3-N
1497-E-AXJK-3-N
1497-E-AXSX-3-N
1497-E-BAJK-3-N
1497-E-BASX-3-N
350
1497-F-HXJX-3-N
1497-F-HXDX-3-N
1497-F-AXJK-3-N
1497-F-AXSX-3-N
1497-F-BAJK-3-N
1497-F-BASX-3-N
500
1497-G-HXJX-3-N
1497-G-HXDX-3-N
1497-G-AXJK-3-N
1497-G-AXSX-3-N
1497-G-BAJK-3-N
1497-G-BASX-3-N
Top-mounted fuse blocks are not available for transformers 750VA and higher.
3
4
5
6
7
8
9
10
11
12
13
www.ab.com/catalogs
Publication A117-CA001A-EN-P
8-41
Bulletin 1497
Cat. Nos.
Primary1
600V (60 Hz)/550V (50 Hz)
Primary
380V, 400V, 415V (50 Hz)
550V
600V
1
2
24V or
120V/110V
3
Continuous VA
4
5
6
Secondary
26V (60 Hz)/24V (50 Hz)
Secondary
120V (60 Hz)/110V (50 Hz)
Secondary
115V/230V (50 Hz)
63
1497-A-CXJK-0-N
1497-A-CXSX-0-N
1497-A-M4-0-N
80
1497-B-CXJK-0-N
1497-B-CXSX-0-N
1497-B-M4-0-N
130
1497-C-CXJK-0-N
1497-C-CXSX-0-N
1497-C-M4-0-N
200
1497-D-CXJK-0-N
1497-D-CXSX-0-N
1497-D-M4-0-N
250
1497-E-CXJK-0-N
1497-E-CXSX-0-N
1497-E-M4-0-N
350
1497-F-CXJK-0-N
1497-F-CXSX-0-N
1497-F-M4-0-N
500
1497-G-CXJK-0-N
1497-G-CXSX-0-N
1497-G-M4-0-N
750
1497-H-CXJK-0-N
1497-H-CXSX-0-N
1497-H-M4-0-N
800
1497-J-CXJK-0-N
1497-J-CXSX-0-N
1497-J-M4-0-N
1000
1497-K-CXJK-0-N
1497-K-CXSX-0-N
1497-K-M4-0-N
1600
1497-L-CXSX-0-N
1497-L-M4-0-N
2000
1497-M-CXSX-0-N
1497-M-M4-0-N
With 2-Pole Primary and 1-Pole Secondary Top-Mounted Fuse Block Fuses Not Included
7
8
63
1497-A-CXJK-3-N
1497-A-CXSX-3-N
80
1497-B-CXJK-3-N
1497-B-CXSX-3-N
1497-B-M4-3-N
130
1497-C-CXJK-3-N
1497-C-CXSX-3-N
1497-C-M4-3-N
200
1497-D-CXJK-3-N
1497-D-CXSX-3-N
1497-D-M4-3-N
250
1497-E-CXJK-3-N
1497-E-CXSX-3-N
1497-E-M4-3-N
350
1497-F-CXJK-3-N
1497-F-CXSX-3-N
1497-F-M4-3-N
500
1497-G-CXJK-3-N
1497-G-CXSX-3-N
1497-G-M4-3-N
Top-mounted fuse blocks are not available for transformers 750VA and higher.
9
10
11
12
13
www.ab.com/catalogs
8-42
Publication A117-CA001A-EN-P
1497-A-M4-3-N
Bulletin 1497
208V
220V
240V
277V
347V
380V
400V
415V
440V
480V
500V
550V
600V
63
0.75
0.75
0.75
0.5
0.5
0.4
0.4
0.4
0.4
0.25
0.25
0.25
0.25
690V
0.25
80
0.75
0.5
0.5
0.5
0.5
0.5
0.5
0.4
0.4
0.4
0.25
130
1.5
1.5
1.5
1.25
0.75
0.75
0.75
0.75
0.75
0.5
0.5
0.5
200
2.5
2.5
2.5
1.5
1.5
1.5
1.25
1.25
1.25
0.75
250
2.5
1.5
1.5
1.5
1.5
1.5
1.5
1.25
1.25
350
2.5
2.5
2.5
1.5
1.5
1.5
500
2.5
2.5
750
800
1000
1600
12
12
11
2000
12
11
13
12
1
2
3
4
Primary Fuse Sizing Chart (When Primary and Secondary Protection is Used)
Maximum Amp Rating for Current Limiting Fuses Based on Transformer Primary Voltage and the National Electrical Code
VA
208V
220V
240V
277V
347V
380V
400V
415V
440V
480V
500V
550V
600V
690V
63
0.75
0.75
0.5
0.5
0.4
0.4
0.4
0.4
0.3
0.3
0.3
0.25
0.25
0.25
80
1.5
1.5
1.5
0.75
0.75
0.75
0.75
0.5
0.5
0.5
130
2.5
2.5
1.5
1.5
1.5
1.5
1.25
1.25
1.25
0.75
200
2.5
2.5
2.5
1.5
1.5
250
2.5
2.5
2.5
1.5
350
2.5
2.5
500
750
800
1000
12
10
10
1600
15
15
15
12
11
10
10
2000
20
20
20
18
14
12
12
12
10
10
10
5
6
7
24V
110V
115V
120V
230V
0.4
63
0.75
0.75
0.75
80
0.5
130
1.8
1.8
1.8
0.9
200
13
2.5
2.5
2.5
1.25
250
15
3.2
3.2
3.2
1.5
2.5
350
20
4.5
4.5
4.5
500
30
6.25
6.25
6.25
750
45
4.5
800
45
4.5
1000
60
12
12
12
1600
100
20
20
20
10
2000
25
25
25
12
8
9
10
11
12
13
www.ab.com/catalogs
Publication A117-CA001A-EN-P
8-43
Bulletin 1497
0
1
2
3
4
Transformer without Fusing
5
6
VA
Without
Top-Mounted
Fuse Block
63
3-7/8
(98.00)
3-1/4
(82.55)
3-1/8
(79.38)
3-1/2
(88.90)
7/32
(5.54)
22/32
(18.29)
2-27/32
(72.39)
2-3/8
(73.91)
4-5/64
(103.51)
3-57/64
(99.01)
4-1/2
(2.04)
4-4/5
(2.18)
80
3-7/8
(98.00)
3-1/4
(82.55)
3-1/8
(79.38)
3-1/2
(88.90)
7/32
(5.54)
22/32
(18.29)
2-27/32
(72.39)
2-3/8
(73.91)
4-5/64
(103.51)
3-57/64
(99.01)
4-1/2
(2.04)
4-4/5
(2.18)
130
3-7/8
(98.00)
3-1/4
(82.55)
3-1/8
(79.38)
3-1/2
(88.90)
7/32
(5.54)
22/32
(18.29)
3-3/8
(85.60)
3-13/32
(86.61)
4-45/64
(119.5)
4-35/64
(115.44)
6-7/10
(3.04)
7-3/20
(3.24)
7
8
9
10
11
Transformer with Fuse Holder and Covers
12
13
VA
Without
Top-Mounted
Fuse Block
200
4-7/8
(123.95)
4-7/16
(112.78)
3-3/4
(95.25)
4-1/2
(114.30)
7/32
(5.59)
1-1/8
(28.70)
3-3/8
(85.60)
3-29/32
(86.61)
5-21/64
(135.26)
5-11/64
(131.44)
8-2/5
(3.81)
8-7/10
(3.95)
250
4-7/8
(123.95)
4-7/16
(108.20)
3-3/4
(95.25)
4-1/2
(114.30)
7/32
(5.59)
1-1/8
(28.70)
3-7/8
(98.30)
3-29/32
(98.30)
5-21/64
(135.26)
5-11/64
(131.44)
10-2/5
(4.72)
10-4/5
(4.90)
350
4-7/8
(123.95)
4-7/16
(108.20)
3-3/4
(95.25)
4-1/2
(114.30)
7/32
(5.59)
1-1/8
(28.70)
3-7/8
(98.30)
3-29/32
(98.30)
5-21/64
(135.26)
5-11/64
(131.44)
13-2/5
(6.08)
13-4/5
(6.26)
www.ab.com/catalogs
8-44
Publication A117-CA001A-EN-P
Bulletin 1497
0
1
2
3
4
Transformer without Fusing
VA
500
A
5-1/4
(133.35)
B
4-33/64
(114.81)
C
4-3/8
(111.25)
D
5-1/4
(133.35)
E
5/16
(7.87)
F
45/64
(18.03)
G
4-17/32
(114.81)
H
5-1/2
(139.70)
J
6-3/16
(156.97)
Without
Top-Mounted
Fuse Block
17-3/5
(7.98)
K
5-15/16
(150.62)
5
6
7
8
9
10
750
5-3/4
(146.05)
5
(127.51)
4-3/8
(111.25)
5-1/4
(133.35)
5/16
(7.87)
45/64
(18.03)
4-9/16
(114.81)
5-19/32
(137.41)
21-1/2
(9.75)
800
5-3/4
(146.05)
5
(127.51)
4-3/8
(111.25)
5-1/4
(133.35)
5/16
(7.87)
45/64
(18.03)
4-9/16
(114.81)
5-19/32
(137.41)
21-1/2
(9.75)
1000
6-3/8
(161.92)
5-3/8
(136.53)
5-5/16
(134.94)
6-3/8
(161.92)
5/16
(7.87)
45/64
(18.03)
5-33/64
(140.21)
6-1/2
(162.56)
37-1/5
(16.87)
1600
8-1/2
(215.90)
7-1/4
(184.15)
5-3/4
(143.76)
6-3/4
(171.45)
7/16
(10.92)
45/64
(18.03)
5-3/4
(146.05)
7-1/16
(168.66)
50-4/5
(23.04)
2000
9-1/2
(241.30)
8-1/4
(209.55)
5-3/4
(143.76)
6-3/4
(171.45)
7/16
(10.92)
45/64
(18.03)
5-11/64
(149.86)
7-1/16
(172.47)
61
(27.67)
www.ab.com/catalogs
12
13
Publication A117-CA001A-EN-P
11
8-45
Bulletin 1497A
Table of Contents
Standards Compliance
UL 5085-1, UL 5085-2
CSA C22.2 No. 66.1
Certifications
cULus Listed (File No. E52057;
Guide No. XPTQ, XPTQ7)
1497A A1 M6 0 N
5
6
7
8
9
VA Rating
Code
Description [VA]
A1
50
A2
75
A3
100
A4
150
A5
200
A6
250
A7
300
A8
350
A9
500
A10
750
A11
1000
A12
1500
A13
2000
A14
3000
Code
Primary
M6
220X440V,
230X460V,
240X480V
Secondary
110, 115, 120V
(50/60 Hz)
M7
230/460/575V
M8
208/277/380V
M18
208/230/480V
(50/60 Hz)
M19
240X480V
(50/60 Hz)
Code
Block Options
0 Primary, 0 Secondary
0 Primary, 1 Secondary
2 Primary, 1 Secondary
Code
Description
No Taps
Note: For complete list of valid transformer configurations, see Product Selection.
Transformers rated 350VA and below use secondary fuse clips. Transformers rated 500VA and above use secondary fuse blocks.
10
11
12
13
www.ab.com/catalogs
8-46
Publication A117-CA001A-EN-P
Bulletin 1497A
85%
90%
95%
Power
Factor
Multiply By
50
158
139
116
100%
0.63
75
242
213
177
90%
0.65
100
346
302
249
80%
0.70
150
528
461
379
70%
0.75
200
869
743
585
60%
0.82
250
1057
904
719
50%
0.90
300
1418
1200
937
40%
1.00
350
1620
1361
1047
30%
1.12
500
2681
2221
1648
20%
1.27
750
4560
3718
2700
10%
1.45
1000
7568
6118
4185
1500
15724
12423
8203
2000
16941
13660
9484
3000
25680
20180
13797
0
1
2
3
4
5
6
7
8
9
10
11
12
13
www.ab.com/catalogs
Publication A117-CA001A-EN-P
8-47
Bulletin 1497A
Primary
230/460/575V (50/60 Hz)
Primary
208/277/380V (50/60 Hz)
Primary
208/230/480V (50/60 Hz)
Primary
240X480V (50/60 Hz)
Continuous
VA
Secondary
110, 115, 120V
Secondary
115/95V
Secondary
115/95V
Secondary
120/24V
Secondary
48V
50
1497A-A1-M6-0-N
1497A-A1-M7-0-N
1497A-A1-M8-0-N
1497A-A1-M18-0-N
1497A-A1-M19-0-N
75
1497A-A2-M6-0-N
1497A-A2-M7-0-N
1497A-A2-M8-0-N
1497A-A2-M18-0-N
1497A-A2-M19-0-N
100
1497A-A3-M6-0-N
1497A-A3-M7-0-N
1497A-A3-M8-0-N
1497A-A3-M18-0-N
1497A-A3-M19-0-N
150
1497A-A4-M6-0-N
1497A-A4-M7-0-N
1497A-A4-M8-0-N
1497A-A4-M18-0-N
1497A-A4-M19-0-N
200
1497A-A5-M6-0-N
1497A-A5-M7-0-N
1497A-A5-M8-0-N
1497A-A5-M18-0-N
1497A-A5-M19-0-N
250
1497A-A6-M6-0-N
1497A-A6-M7-0-N
1497A-A6-M8-0-N
1497A-A6-M18-0-N
1497A-A6-M19-0-N
300
1497A-A7-M6-0-N
1497A-A7-M7-0-N
1497A-A7-M8-0-N
1497A-A7-M18-0-N
1497A-A7-M19-0-N
350
1497A-A8-M6-0-N
1497A-A8-M7-0-N
1497A-A8-M8-0-N
1497A-A8-M18-0-N
1497A-A8-M19-0-N
1
2
3
4
5
6
500
1497A-A9-M6-0-N
1497A-A9-M7-0-N
1497A-A9-M8-0-N
1497A-A9-M19-0-N
750
1497A-A10-M6-0-N
1497A-A10-M7-0-N
1497A-A10-M8-0-N
1497A-A10-M19-0-N
1000
1497A-A11-M6-0-N
1497A-A11-M7-0-N
1497A-A11-M8-0-N
1497A-A11-M19-0-N
1500
1497A-A12-M6-0-N
1497A-A12-M7-0-N
1497A-A12-M8-0-N
2000
1497A-A13-M6-0-N
1497A-A13-M7-0-N
1497A-A13-M8-0-N
3000
1497A-A14-M6-0-N
Primary
230/460/575V (50/60 Hz)
Primary
208/277/380V (50/60 Hz)
Primary
208/230/480V (50/60 Hz)
Primary
240X480V (50/60 Hz)
Continuous
VA
Secondary
110, 115, 120V
Secondary
115/95V
Secondary
115/95V
Secondary
120/24V
Secondary
48V
50
1497A-A1-M6-1-N
1497A-A1-M7-1-N
1497A-A1-M8-1-N
1497A-A1-M18-1-N
1497A-A1-M19-1-N
75
1497A-A2-M6-1-N
1497A-A2-M7-1-N
1497A-A2-M8-1-N
1497A-A2-M18-1-N
1497A-A2-M19-1-N
100
1497A-A3-M6-1-N
1497A-A3-M7-1-N
1497A-A3-M8-1-N
1497A-A3-M18-1-N
1497A-A3-M19-1-N
150
1497A-A4-M6-1-N
1497A-A4-M7-1-N
1497A-A4-M8-1-N
1497A-A4-M18-1-N
1497A-A4-M19-1-N
200
1497A-A5-M6-1-N
1497A-A5-M7-1-N
1497A-A5-M8-1-N
1497A-A5-M18-1-N
1497A-A5-M19-1-N
250
1497A-A6-M6-1-N
1497A-A6-M7-1-N
1497A-A6-M8-1-N
1497A-A6-M18-1-N
1497A-A6-M19-1-N
300
1497A-A7-M6-1-N
1497A-A7-M7-1-N
1497A-A7-M8-1-N
1497A-A7-M18-1-N
1497A-A7-M19-1-N
350
1497A-A8-M6-1-N
1497A-A8-M7-1-N
1497A-A8-M8-1-N
1497A-A8-M18-1-N
1497A-A8-M19-1-N
500
1497A-A9-M6-1-N
1497A-A9-M7-1-N
1497A-A9-M8-1-N
1497A-A9-M19-1-N
750
1497A-A10-M6-1-N
1497A-A10-M7-1-N
1497A-A10-M8-1-N
1497A-A10-M19-1-N
1000
1497A-A11-M6-1-N
1497A-A11-M7-1-N
1497A-A11-M8-1-N
1497A-A11-M19-1-N
1500
1497A-A12-M6-1-N
1497A-A12-M7-1-N
1497A-A12-M8-1-N
2000
1497A-A13-M6-1-N
1497A-A13-M7-1-N
1497A-A13-M8-1-N
3000
1497A-A14-M6-1-N
7
8
9
10
11
12
Secondary Fuse Block/Clip: Transformers rated 350VA and below use secondary fuse clips. Transformers rated 500VA and above use secondary fuse blocks.
13
www.ab.com/catalogs
8-48
Publication A117-CA001A-EN-P
Bulletin 1497A
Cat. Nos.
Primary
220x440V, 230x460V,
240x480V (50/60 Hz)
Primary
230/460/575V (50/60 Hz)
Primary
208/277/380V (50/60 Hz)
Primary
240X480V
(50/60 Hz)
Primary
208/230/480V (50/60 Hz)
Continuous
VA
Secondary
110, 115, 120V
Secondary
115/95V
Secondary
115/95V
Secondary
120/24V
Secondary
48V
50
1497A-A1-M6-3-N
1497A-A1-M7-3-N
1497A-A1-M8-3-N
1497A-A1-M18-3-N
1497A-A1-M19-3-N
75
1497A-A2-M6-3-N
1497A-A2-M7-3-N
1497A-A2-M8-3-N
1497A-A2-M18-3-N
1497A-A2-M19-3-N
100
1497A-A3-M6-3-N
1497A-A3-M7-3-N
1497A-A3-M8-3-N
1497A-A3-M18-3-N
1497A-A3-M19-3-N
150
1497A-A4-M6-3-N
1497A-A4-M7-3-N
1497A-A4-M8-3-N
1497A-A4-M18-3-N
1497A-A4-M19-3-N
200
1497A-A5-M6-3-N
1497A-A5-M7-3-N
1497A-A5-M8-3-N
1497A-A5-M18-3-N
1497A-A5-M19-3-N
250
1497A-A6-M6-3-N
1497A-A6-M7-3-N
1497A-A6-M8-3-N
1497A-A6-M18-3-N
1497A-A6-M19-3-N
300
1497A-A7-M6-3-N
1497A-A7-M7-3-N
1497A-A7-M8-3-N
1497A-A7-M18-3-N
1497A-A7-M19-3-N
350
1497A-A8-M6-3-N
1497A-A8-M7-3-N
1497A-A8-M8-3-N
1497A-A8-M18-3-N
1497A-A8-M19-3-N
500
1497A-A9-M6-3-N
1497A-A9-M7-3-N
1497A-A9-M8-3-N
1497A-A9-M19-3-N
750
1497A-A10-M6-3-N
1497A-A10-M7-3-N
1497A-A10-M8-3-N
1497A-A10-M19-3-N
1000
1497A-A11-M6-3-N
1497A-A11-M7-3-N
1497A-A11-M8-3-N
1497A-A11-M19-3-N
1500
1497A-A12-M6-3-N
1497A-A12-M7-3-N
1497A-A12-M8-3-N
2000
1497A-A13-M6-3-N
1497A-A13-M7-3-N
1497A-A13-M8-3-N
3000
1497A-A14-M6-3-N
3
4
5
Secondary Fuse Block/Clip: Transformers rated 350VA and below use secondary fuse clips. Transformers rated 500VA and above use secondary fuse blocks.
Maximum Amp Rating for Current Limiting Class C Fuses Based on Transformer Primary Voltage and the National Electrical Code
VA
115V
120V
200V
208V
220V
50
1.25
75
1.8
100
150
230V
240V
277V
380V
400V
1.25
0.75
0.6
0.6
0.6
0.6
0.5
0.3
0.3
0.3
0.3
0.3
1.8
1.125
0.75
0.75
0.75
0.5
0.5
0.5
0.5
0.4
2.5
2.5
1.5
1.4
1.25
1.25
1.25
0.75
0.75
0.6
0.6
0.6
3.5
3.5
2.25
1.8
1.8
1.6
1.125 1.125
415V
440V
460V
480V
500V
550V
575V
600V
0.3
0.3
0.25
0.25
0.25
0.4
0.4
0.4
0.3
0.3
0.6
0.6
0.5
0.5
0.5
0.75
0.75
0.75
0.75
0.75
0.75
200
2.8
2.5
2.5
2.5
1.5
1.5
1.4
1.25
1.25
1.25
1.125
250
3.5
3.2
3.5
3.5
3.2
3.2
2.5
1.8
1.8
1.8
1.6
1.6
1.5
1.5
1.25
1.25
1.25
300
4.5
3.5
3.5
3.2
2.25
2.25
1.8
1.8
1.8
1.6
1.5
1.5
350
4.5
4.5
4.5
3.5
2.5
2.5
2.5
2.25
2.25
1.8
1.8
1.6
500
6.25
3.5
3.5
3.2
3.5
3.5
3.5
3.2
3.2
2.5
2.5
2.5
750
10
10
6.25
5.6
4.5
5.6
5.6
4.5
4.5
4.5
3.5
3.5
1000
12
12
6.25
3.5
3.5
3.2
3.2
1500
20
15
12
12
10
10
10
6.25
6.25
5.6
4.5
2000
20
20
12
12
10
12
12
12
6.25
6.25
5.6
3000
30
30
15
15
15
15
15
12
12
12
12
10
10
10
10
8
9
10
11
12
13
www.ab.com/catalogs
Publication A117-CA001A-EN-P
8-49
Bulletin 1497A
Important: Select the fuse to protect the control circuit conductors in accordance with the National Electrical Code.
1
2
3
4
VA
115V
120V
200V
208V
220V
230V
240V
277V
380V
400V
415V
440V
460V
480V
500V
550V
575V
600V
50
1.25
1.25
0.75
0.6
0.6
0.6
0.6
0.5
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.25
0.25
0.25
75
1.8
1.8
1.125
0.75
0.75
0.75
0.5
0.5
0.5
0.5
0.4
0.4
0.4
0.4
0.3
0.3
100
2.5
2.5
1.5
1.4
1.25
1.25
1.25
0.75
0.75
0.6
0.6
0.6
0.6
0.6
0.5
0.5
0.5
150
3.5
3.5
2.25
1.8
1.8
1.6
0.75
0.75
0.75
0.75
0.75
0.75
200
2.8
2.5
2.5
2.5
1.5
1.5
1.4
1.25
1.25
1.25
1.125
250
3.5
3.2
3.5
3.5
3.2
3.2
2.5
1.8
1.8
1.8
1.6
1.6
1.5
1.5
1.25
1.25
1.25
300
4.5
3.5
3.5
3.2
2.25
2.25
1.8
1.8
1.8
1.6
1.5
1.5
350
4.5
4.5
4.5
3.5
2.5
2.5
2.5
2.25
2.25
1.8
1.8
1.6
500
6.25
3.5
3.5
3.2
3.5
3.5
3.5
3.2
3.2
2.5
2.5
2.5
3.5
1.125 1.125
750
10
10
6.25
5.6
4.5
5.6
5.6
4.5
4.5
4.5
3.5
1000
12
12
6.25
3.5
3.5
3.2
3.2
1500
20
15
12
12
10
10
10
6.25
6.25
5.6
4.5
2000
20
20
12
12
10
12
12
12
6.25
6.25
5.6
3000
30
30
15
15
15
15
15
12
12
12
12
10
10
10
10
600V
Primary Fuse Sizing Chart (When primary and secondary protection is used)
Maximum Amp rating for current limiting fuses based on transformer primary voltage and the National Electrical Code
5
6
7
8
9
10
11
12
VA
115V
120V
200V
208V
220V
230V
240V
277V
380V
400V
415V
440V
460V
480V
500V
550V
575V
50
0.6
0.6
0.5
0.5
0.5
0.4
0.3
0.3
0.3
0.25
0.25
0.25
0.25
0.2
0.2
0.2
75
1.6
1.5
0.75
0.75
0.75
0.75
0.75
0.6
0.4
0.4
0.4
0.4
0.4
0.3
0.3
0.3
0.3
0.3
1.125 1.125
100
1.25
150
3.2
1.8
1.8
200
2.5
2.25
250
2.8
2.5
300
6.25
6.25
3.5
3.5
3.2
3.2
1.6
0.75
0.6
0.6
0.6
0.5
0.5
0.5
0.5
0.4
0.4
0.4
1.6
1.5
1.25
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.6
0.6
0.6
1.8
1.25
1.25
1.125 1.125
0.75
0.75
0.75
2.5
2.25
1.6
1.5
1.5
1.4
1.25
1.25
1.25
1.125
2.5
1.8
1.8
1.8
1.6
1.6
1.5
1.5
1.25
1.25
1.25
350
3.5
3.5
3.5
2.25
1.8
1.8
1.8
1.6
1.5
1.5
1.4
500
10
10
6.25
5.6
4.5
3.2
2.8
2.5
2.5
2.5
2.25
750
15
15
6.25
4.5
4.5
4.5
3.5
3.5
3.2
3.2
1000
20
20
12
12
10
10
10
6.25
6.25
5.6
4.5
1500
30
30
15
15
15
15
15
12
6.25
6.25
6.25
2000
40
40
25
20
20
20
20
15
12
12
12
10
10
10
10
3000
45
45
35
35
30
30
30
25
15
15
15
15
15
15
15
12
12
12
23V
24V
25V
85V
90V
95V
100V
110V
115V
120V
125V
130V
220V
230V
240V
50
3.5
3.2
3.2
0.75
0.75
0.75
0.75
0.75
0.6
0.6
0.6
0.6
0.3
0.3
0.3
75
1.4
1.25
1.25
1.25
1.125
0.75
0.5
0.5
0.5
100
6.25
6.25
1.8
1.8
1.6
1.6
1.5
1.4
1.25
1.25
1.25
0.75
0.6
0.6
150
10
10
10
2.8
2.5
2.5
2.5
2.25
1.8
1.125
200
12
12
12
3.5
3.5
3.5
3.2
2.8
2.5
2.5
2.5
1.5
1.4
1.25
250
15
15
15
4.5
4.5
3.5
3.5
3.2
3.2
3.2
1.8
1.8
1.6
300
20
20
20
5.6
4.5
3.5
2.25
350
20
20
20
6.25
6.25
5.6
4.5
4.5
2.5
2.5
2.25
500
6.25
6.25
6.25
3.5
3.5
3.2
750
12
12
12
12
10
10
10
10
5.6
1000
15
15
15
15
15
12
12
12
12
6.25
1500
25
25
25
25
20
20
20
20
15
10
10
10
2000
35
35
35
30
30
25
25
25
25
15
12
12
3000
45
40
40
40
35
20
20
20
13
www.ab.com/catalogs
8-50
Publication A117-CA001A-EN-P
Bulletin 1497A
0
1
2
Transformer with 0 Primary Fuse Blocks
and 0 or 1 Secondary Fuse Block/Clip
(Top View)
3
4
5
6
VA
Cat. No.
1497A-A1-M6-__-N
3-25/32
(96)
1497A-A1-M7-__-N
50
1497A-A1-M8-__-N
4-1/32
(102)
1-31/32
(50)
3 (76)
2-23/32
(69)
Approx.
Shipping
Wt.
lb (kg)
2-1/5 (56)
2-1/2 (64)
15/32 (12)
1/5 (5)
3-9/64 (80)
4 (1.8)
3-25/32
(96)
1-31/32
(50)
4 (1.8)
1497A-A2-M6-__-N
4-1/32
(102)
2-27/64
(61)
4 (1.8)
1497A-A2-M8-__-N
2-23/32
(69)
4-17/32
(115)
2-53/64
(72)
4-1/32
(102)
1497A-A1-M19-__-N
3 (76)
2-1/2 (64)
3-9/64 (80)
2-5/8 (67)
15/32 (12)
4-1/32
(102)
3-3/64 (77)
3 (76)
2-13/16
(71)
3-15/32
(88)
4-23/64
(110)
5 (2.3)
4-1/32
(102)
3 (76)
2-23/32
(69)
2-27/64
(61)
2-1/2 (64)
3-9/64 (80)
4-1/32
(102)
5 (2.3)
1497A-A3-M6-__-N
4 (102)
3-3/8 (86)
3-3/64 (77)
2-27/64
(61)
2-13/16
(71)
3-15/32
(88)
4-23/64
(110)
5 (2.3)
1497A-A3-M7-__-N
4-1/16
(103)
3-3/4 (95)
3-23/64
(85)
3-5/16 (80)
3-49/64
(96)
4-21/32
(118)
1497A-A3-M18-__-N
4-17/32
(115)
1497A-A3-M19-__-N
4 (102)
15/32 (12)
1/5 (5)
3 (76)
3-3/8 (86)
3-3/64 (77)
www.ab.com/catalogs
2-27/64
(61)
9
10
5 (2.3)
1/5 (5)
3-3/8 (86)
2-13/16
(71)
4 (1.8)
1497A-A2-M19-__-N
1497A-A3-M8-__-N
3 (1.4)
1497A-A1-M18-__-N
1497A-A2-M18-__-N
100
4-17/32
(115)
1497A-A2-M7-__-N
75
11
12
6 (2.7)
6 (2.7)
2-13/16
(71)
3-15/32
(88)
4-23/64
(110)
6 (2.7)
Publication A117-CA001A-EN-P
8-51
13
Bulletin 1497A
0
1
VA
Cat. No.
1497A-A4-M6-__-N
4-1/16
(103)
1497A-A4-M7-__-N
150
1497A-A4-M8-__-N
4-17/32
(115)
1497A-A4-M18-__-N
5-1/16
(129)
1497A-A4-M19-__-N
4-1/16
(103)
2-13/16
(71)
3-3/4 (95)
3-23/64
(85)
3-3/16 (81)
3-49/64
(96)
3-5/16 (80)
15/32 (12)
1/5 (5)
3-25/32
(96)
6 (2.7)
4-21/32
(118)
7 (3.2)
7 (3.2)
3-49/64
(96)
2-13/16
(71)
Approx.
Shipping
Wt.
lb (kg)
7 (3.2)
1497A-A5-M6-__-N
1497A-A5-M7-__-N
200
1497A-A5-M8-__-N
2-5/8 (67)
4-3/8 (111)
4-1/2 (114)
3-31/32
(101)
10 (4.5)
3-3/4 (95)
15/32 (12)
1/5 (5)
4-2/5 (112)
5-9/32
(134)
1497A-A5-M18-__-N
2-63/64
(76)
1497A-A5-M19-__-N
2-5/8 (67)
10 (4.5)
2-53/64
(72)
10 (4.5)
10 (4.5)
1497A-A6-M6-__-N
1497A-A6-M7-__-N
4-3/8 (111)
1497A-A6-M8-__-N
4-1/2 (114)
250
1497A-A6-M18-__-N
4-3/4 (120)
1497A-A6-M19-__-N
4-3/8 (111)
3-31/32
(101)
3-15/32
(88)
3-3/4 (95)
15/32 (12)
1/5 (5)
4-2/5 (112)
5-9/32
(134)
2-53/64
(72)
10 (4.5)
10 (4.5)
1497A-A7-M6-__-N
4-3/4 (120)
4-1/2 (114)
3-31/32
(101)
3-3/16 (81)
3-3/4 (95)
15/32 (12)
1/5 (5)
4-2/5 (112)
5-9/32
(134)
12 (5.4)
1497A-A7-M18-__-N
6-7/64
(155)
5-1/4 (133)
4-5/8 (118)
3-7/8 (98)
4-3/8 (111)
1-1/16 (27)
5/16 (8)
4-2/5 (112)
5-15/16
(151)
12 (5.4)
1497A-A7-M19-__-N
4-3/4 (120)
4-1/2 (114)
3-31/32
(101)
3-3/16 (81)
3-3/4 (95)
15/32 (12)
1/5 (5)
4-2/5 (112)
5-9/32
(134)
12 (5.4)
1497A-A8-M6-__-N
4-3/4 (120)
1497A-A8-M7-__-N
4-63/64
(128)
4-1/2 (114)
3-31/32
(101)
3-3/4 (95)
3-3/4 (95)
15/32 (12)
1/5 (5)
4-2/5 (112)
5-9/32
(134)
1497A-A7-M7-__-N
1497A-A7-M8-__-N
300
1497A-A8-M8-__-N
350
3-3/16 (81)
12 (5.4)
1497A-A8-M18-__-N
6-7/64
(155)
5-1/4 (133)
4-5/8 (118)
3-7/8 (98)
4-3/8 (111)
1-1/16 (27)
5/16 (8)
4-2/5 (112)
5-15/16
(151)
14 (6.4)
1497A-A8-M19-__-N
4-3/4 (120)
4-1/2 (114)
3-31/32
(101)
3-3/16 (81)
3-3/4 (95)
15/32 (12)
1/5 (5)
4-2/5 (112)
5-9/32
(134)
14 (6.4)
6-7/64
(155)
5-1/4 (133)
4-5/8 (118)
3-7/8 (98)
4-3/8 (111)
1-1/16 (27)
5/16 (8)
4-2/5 (112)
5-15/16
(151)
1497A-A9-M6-__-N
500
1497A-A9-M7-__-N
1497A-A9-M8-__-N
19 (8.6)
1497A-A9-M19-__-N
1497A-A10-M6-__-N
750
1497A-A10-M7-__-N
1497A-A10-M8-__-N
1497A-A10-M19-__-N
10
1497A-A11-M7-__-N
1497A-A11-M8-__-N
8-7/64
(206)
28 (12.7)
5-1/4 (133)
4-5/8 (118)
5-7/8 (149)
4-3/8 (111)
1-1/16 (27)
5/16 (8)
4-2/5 (112)
5-15/16
(151)
7-39/64
(193)
40 (18.1)
7-7/64
(181)
6-3/4 (171)
5-55/64
(149)
4-31/32
(126)
6-1/8 (155)
9/10 (23)
5/16 (8)
4-2/5 (112)
7-3/16
(183)
1497A-A12-M7-__-N
1497A-A13-M6-__-N
12
1497A-A13-M7-__-N
1497A-A13-M8-__-N
3000
1497A-A14-M6-__-N
6-3/4 (171)
5-55/64
(149)
6-1/8 (155)
6-1/8 (155)
7/8 (22)
5/16 (8)
4-2/5 (112)
7-3/16
(183)
55 (24.9)
54 (24.5)
8-7/64
(206)
53 (24)
6-3/4 (171)
5-55/64
(149)
9 (229)
7-41/64
(194)
9 (229)
8 (203)
6-1/8 (155)
6-1/8 (155)
7/8 (22)
5/16 (8)
4-2/5 (112)
7-3/16
(183)
4-2/5 (112)
8-61/64
(227)
61 (27.7)
58 (26.3)
5-1/4 (133)
7-1/2 (191)
9/10 (23)
7/16 (11)
13
www.ab.com/catalogs
8-52
41 (18.6)
53 (24)
8-7/64
(206)
1497A-A12-M8-__-N
2000
42 (19.1)
41 (18.6)
1497A-A12-M6-__-N
1500
32 (14.5)
31 (14.1)
31 (14.1)
1497A-A11-M19-__-N
11
18 (8.2)
18 (8.2)
7-39/64
(193)
1497A-A11-M6-__-N
1000
14 (6.4)
Publication A117-CA001A-EN-P
72 (32.7)
Bulletin 1497B
Table of Contents
Standards Compliance
0
1
UL 5085-1, UL 5085-2
CSA C22.2 No. 66.1
Certifications
cULus Listed (File No. E52057;
Guide No. XPTQ, XPTQ7)
1497B A3 M11 0 N
a
VA Rating
Code
Description [VA]
Code
Primary
Secondary
Code
Block Options
A1
50
M11
600/575/550V
0 Primary, 0 Secondary
A2
75
M12
120X240V
0 Primary, 1 Secondary
A3
100
M13
120X240V
2 Primary, 0 Secondary
A4
150
M14
240X480V
2 Primary, 1 Secondary
A5
200
M15
380/400/416V
A6
250
M16
240X480V
A7
300
M17
208/240V
A9
500
A10
750
A11
1000
A12
1500
A13
2000
A14
3000
5
6
d
Factory Installed Options
Code
Description
No Taps
7
8
Note: For complete list of valid transformer configurations, see Product Selection.
Transformers rated 350VA and below use secondary fuse clips. Transformers rated 500VA and above use secondary fuse blocks.
9
10
11
12
13
www.ab.com/catalogs
Publication A117-CA001A-EN-P
8-53
Bulletin 1497B
0
1
2
3
4
5
6
7
8
Continuous
VA
12
Secondary 120X240V
(60 Hz)
Secondary 120X240V
(60 Hz)
Cat. No.
Cat. No.
1497B-A3-M11-0-N
1497B-A3-M12-0-N
200
1497B-A5-M11-0-N
1497B-A5-M12-0-N
300
1497B-A7-M11-0-N
1497B-A7-M12-0-N
500
1497B-A9-M11-0-N
1497B-A9-M12-0-N
Selection Process
750
1497B-A10-M12-0-N
1. Determine the total inrush VA of the control circuits from the table
below, Typical Magnetic Motor Starter and Contactor Data 60 Hz,
120 Volt, 3-Pole. Do not neglect the current requirements of
indicating lights and other devices that do not have an inrush VA
but are re-energized at the same time as the other components in
the circuit. Their total VA should be added to the total inrush VA.
1000
1497B-A11-M11-0-N
1497B-A11-M12-0-N
2000
1497B-A13-M11-0-N
1497B-A13-M12-0-N
3000
1497B-A14-M11-0-N
1497B-A14-M12-0-N
Primary
120x240V (60 Hz)
Primary
240x480V (60 Hz)
Primary
208/240V (60 Hz)
Secondary 24V
(60 Hz)
Secondary 24V
(60 Hz)
Secondary 24V
(60 Hz)
Cat. No.
Cat. No.
Cat. No.
11
100
Continuous
VA
50
75
1497B-A2-M13-0-N
100
150
200
1497B-A5-M13-0-N
250
300
1497B-A7-M13-0-N
10
Primary 600/575/550V
(60 Hz)
Primary 380/400/416V
(60 Hz)
Secondary 120X240V
(60 Hz)
Secondary 115X230V
(60 Hz)
Power Factor
Adjustments
85%
90%
95%
Power
Factor
Multiply By
50
158
139
116
100%
0.63
75
242
213
177
90%
0.65
100
346
302
249
80%
0.70
150
528
461
379
70%
0.75
200
869
743
585
60%
0.82
Continuous
VA
Cat. No.
Cat. No.
250
1057
904
719
50%
0.90
100
1497B-A3-M14-0-N
300
1418
1200
937
40%
1.00
150
1497B-A4-M14-0-N
500
2681
2221
1648
20%
1.27
200
1497B-A6-M14-0-N
750
4560
3718
2700
10%
1.45
500
1497B-A9-M14-0-N
1497B-A9-M15-0-N
1000
7568
6118
4185
750
1497B-A10-M14-0-N
1497B-A10-M15-0-N
1500
15724
12423
8203
1000
1497B-A11-M14-0-N
1497B-A11-M15-0-N
2000
16941
13660
9484
1500
1497B-A12-M14-0-N
1497B-A12-M15-0-N
3000
25680
20180
13797
2000
1497B-A13-M14-0-N
1497B-A13-M15-0-N
3000
1497B-A14-M14-0-N
1497B-A14-M15-0-N
13
www.ab.com/catalogs
8-54
Publication A117-CA001A-EN-P
Bulletin 1497B
Primary
240x480V (60 Hz)
Primary
208/240V (60 Hz)
1
2
Continuous
VA
Secondary 120X240V
(60 Hz)
Secondary 120X240V
(60 Hz)
Secondary 24V
(60 Hz)
Secondary 24V
(60 Hz)
Secondary 24V
(60 Hz)
Cat. No.
Cat. No.
Cat. No.
Cat. No.
Cat. No.
Continuous
VA
100
1497B-A3-M11-2-N
1497B-A3-M12-2-N
50
200
1497B-A5-M11-2-N
1497B-A5-M12-2-N
75
1497B-A2-M13-3-N
300
1497B-A7-M11-2-N
1497B-A7-M12-2-N
100
150
200
1497B-A5-M13-3-N
250
300
1497B-A7-M13-3-N
3
4
5
6
Cat. No.
Cat. No.
Cat. No.
Cat. No.
500
1497B-A9-M11-3-N
1497B-A9-M12-3-N
1497B-A9-M14-3-N
1497B-A9-M15-3-N
750
1497B-A10-M12-3-N
1497B-A10-M14-3-N
1497B-A10-M15-3-N
1000
1497B-A11-M11-3-N
1497B-A11-M12-3-N
1497B-A11-M14-3-N
1497B-A11-M15-3-N
1500
1497B-A12-M14-3-N
1497B-A12-M15-3-N
2000
1497B-A13-M11-3-N
1497B-A13-M12-3-N
1497B-A13-M14-3-N
1497B-A13-M15-3-N
3000
1497B-A14-M11-3-N
1497B-A14-M12-3-N
1497B-A14-M14-3-N
1497B-A14-M15-3-N
Continuous
VA
7
8
10
Secondary 24V (60 Hz)
Cat. No.
Cat. No.
Cat. No.
50
1497B-A1-M13-1-N
1497B-A1-M16-1-N
1497B-A1-M17-1-N
Continuous
VA
75
1497B-A2-M13-1-N
100
1497B-A3-M13-1-N
1497B-A3-M16-1-N
1497B-A3-M17-1-N
150
1497B-A4-M13-1-N
1497B-A4-M16-1-N
1497B-A4-M17-1-N
200
1497B-A5-M13-1-N
250
1497B-A6-M13-1-N
1497B-A6-M16-1-N
1497B-A6-M17-1-N
300
1497B-A7-M13-1-N
11
12
Secondary Fuse Block/Clip: Transformers rated 350VA and below use secondary fuse clips. Transformers rated 500VA and above use secondary fuse blocks.
13
www.ab.com/catalogs
Publication A117-CA001A-EN-P
8-55
Bulletin 1497B
Important: Select the fuse to protect the control circuit conductors in accordance with the National Electrical Code.
1
2
3
4
VA
115V
120V
200V
208V
220V
230V
240V
277V
380V
400V
415V
440V
460V
480V
500V
550V
575V
600V
50
1.25
1.25
0.75
0.6
0.6
0.6
0.6
0.5
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.25
0.25
0.25
75
1.8
1.8
1.125
0.75
0.75
0.75
0.5
0.5
0.5
0.5
0.4
0.4
0.4
0.4
0.3
0.3
100
2.5
2.5
1.5
1.4
1.25
1.25
1.25
0.75
0.75
0.6
0.6
0.6
0.6
0.6
0.5
0.5
0.5
150
3.5
3.5
2.25
1.8
1.8
1.6
0.75
0.75
0.75
0.75
0.75
0.75
200
2.8
2.5
2.5
2.5
1.5
1.5
1.4
1.25
1.25
1.25
1.125
250
3.5
3.2
3.5
3.5
3.2
3.2
2.5
1.8
1.8
1.8
1.6
1.6
1.5
1.5
1.25
1.25
1.25
300
4.5
3.5
3.5
3.2
2.25
2.25
1.8
1.8
1.8
1.6
1.5
1.5
350
4.5
4.5
4.5
3.5
2.5
2.5
2.5
2.25
2.25
1.8
1.8
1.6
500
6.25
3.5
3.5
3.2
3.5
3.5
3.5
3.2
3.2
2.5
2.5
2.5
3.5
1.125 1.125
750
10
10
6.25
5.6
4.5
5.6
5.6
4.5
4.5
4.5
3.5
1000
12
12
6.25
3.5
3.5
3.2
3.2
1500
20
15
12
12
10
10
10
6.25
6.25
5.6
4.5
2000
20
20
12
12
10
12
12
12
6.25
6.25
5.6
3000
30
30
15
15
15
15
15
12
12
12
12
10
10
10
10
600V
Primary Fuse Sizing Chart (When primary and secondary protection is used)
Maximum Amp rating for current limiting fuses based on transformer primary voltage and the National Electrical Code
6
7
8
9
10
11
12
VA
115V
120V
200V
208V
220V
230V
240V
277V
380V
400V
415V
440V
460V
480V
500V
550V
575V
50
0.6
0.6
0.5
0.5
0.5
0.4
0.3
0.3
0.3
0.25
0.25
0.25
0.25
0.2
0.2
0.2
75
1.6
1.5
0.75
0.75
0.75
0.75
0.75
0.6
0.4
0.4
0.4
0.4
0.4
0.3
0.3
0.3
0.3
0.3
1.125 1.125
100
1.25
150
3.2
1.8
1.8
200
2.5
2.25
250
2.8
2.5
300
6.25
6.25
3.5
3.5
3.2
3.2
1.6
0.75
0.6
0.6
0.6
0.5
0.5
0.5
0.5
0.4
0.4
0.4
1.6
1.5
1.25
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.6
0.6
0.6
1.8
1.25
1.25
1.125 1.125
0.75
0.75
0.75
2.5
2.25
1.6
1.5
1.5
1.4
1.25
1.25
1.25
1.125
2.5
1.8
1.8
1.8
1.6
1.6
1.5
1.5
1.25
1.25
1.25
350
3.5
3.5
3.5
2.25
1.8
1.8
1.8
1.6
1.5
1.5
1.4
500
10
10
6.25
5.6
4.5
3.2
2.8
2.5
2.5
2.5
2.25
750
15
15
6.25
4.5
4.5
4.5
3.5
3.5
3.2
3.2
1000
20
20
12
12
10
10
10
6.25
6.25
5.6
4.5
1500
30
30
15
15
15
15
15
12
6.25
6.25
6.25
2000
40
40
25
20
20
20
20
15
12
12
12
10
10
10
10
3000
45
45
35
35
30
30
30
25
15
15
15
15
15
15
15
12
12
12
23V
24V
25V
85V
90V
95V
100V
110V
115V
120V
125V
130V
220V
230V
240V
50
3.5
3.2
3.2
0.75
0.75
0.75
0.75
0.75
0.6
0.6
0.6
0.6
0.3
0.3
0.3
75
1.4
1.25
1.25
1.25
1.125
0.75
0.5
0.5
0.5
100
6.25
6.25
1.8
1.8
1.6
1.6
1.5
1.4
1.25
1.25
1.25
0.75
0.6
0.6
150
10
10
10
2.8
2.5
2.5
2.5
2.25
1.8
1.125
200
12
12
12
3.5
3.5
3.5
3.2
2.8
2.5
2.5
2.5
1.5
1.4
1.25
250
15
15
15
4.5
4.5
3.5
3.5
3.2
3.2
3.2
1.8
1.8
1.6
300
20
20
20
5.6
4.5
3.5
2.25
350
20
20
20
6.25
6.25
5.6
4.5
4.5
2.5
2.5
2.25
500
6.25
6.25
6.25
3.5
3.5
3.2
750
12
12
12
12
10
10
10
10
5.6
1000
15
15
15
15
15
12
12
12
12
6.25
1500
25
25
25
25
20
20
20
20
15
10
10
10
2000
35
35
35
30
30
25
25
25
25
15
12
12
3000
45
40
40
40
35
20
20
20
13
www.ab.com/catalogs
8-56
Publication A117-CA001A-EN-P
Bulletin 1497B
0
1
2
3
Transformer with 2 Primary Fuse Blocks and 0 or 1 Secondary Fuse
Block/Clip
(Top View)
4
5
6
7
Transformer with 2 Primary Fuse Blocks and 1 Secondary Fuse
Block/Clip
(Side View)
8
9
10
11
Transformer with 2 Primary Fuse Blocks and 1 Secondary Fuse
Block/Clip
(Side View)
12
13
www.ab.com/catalogs
Publication A117-CA001A-EN-P
8-57
Bulletin 1497B
VA
Cat. No.
Approx.
Shipping
Wt.
lb (kg)
3-25/32
(96)
3
(76)
2-23/32
(69)
1-31/32
(50)
2-1/2
(64)
15/32
(12)
1/5
(5)
3-9/64
(80)
4-1/32
(102)
3 (1.4)
1497B-A2-M13-0-N
4-1/32
(102)
3
(76)
2-23/32
(69)
2-27/64
(61)
2-1/2
(64)
15/32
(12)
1/5
(5)
3-9/64
(80)
4-1/32
(102)
4 (1.8)
1497B-A3-M11-0-N
4-1/16
(103)
3-3/4
(95)
3-23/64
(85)
2-13/32
(61)
3-1/8
(80)
3-49/64
(96)
4-21/32
(118)
4
(102)
3-3/8
(86)
3-3/64
(77)
2-27/64
(61)
2-13/16
(71)
3-15/32
(88)
4-23/64
(110)
4-1/16
(103)
3-3/4
(95)
3-23/64
(85)
2-13/16
(71)
4-3/8
(111)
4-1/2
(114)
3-31/32
(101)
4-3/8
(111)
4-1/2
(114)
4-3/4
(120)
1497B-A1-M13-0-N
50
1
2
1497B-A1-M16-0-N
1497B-A1-M17-0-N
75
1497B-A3-M12-0-N
100
15/32
(12)
1/5
(5)
3-5/16
(80)
15/32
(12)
1/5
(5)
3-49/64
(96)
4-21/32
(118)
6 (2.7)
2-5/8
(67)
3-3/4
(95)
15/32
(12)
1/5
(5)
4-2/5
(112)
5-9/32
(134)
10 (4.5)
3-31/32
(101)
2-53/64
(72)
3-3/4
(95)
15/32
(12)
1/5
(5)
4-2/5
(112)
5-9/32
(134)
10 (4.5)
4-1/2
(114)
3-31/32
(101)
3-3/16
(81)
3-3/4
(95)
15/32
(12)
1/5
(5)
4-2/5
(112)
5-9/32
(134)
12 (5.4)
6-7/64
(155)
5-1/4
(133)
4-5/8
(118)
3-7/8
(98)
4-3/8
(111)
1-1/16
(27)
5/16
(8)
5-15/16
(151)
18 (8.2)
7-39/64
(193)
5-1/4
(133)
4-5/8
(118)
5-7/8
(149)
4-3/8
(111)
1-1/16
(27)
5/16
(8)
5-15/16
(151)
28 (12.7)
7-7/64
(181)
6-3/4
(171)
5-55/64
(149)
4-31/32
(126)
6-1/8
(155)
9/10
(23)
5/16
(8)
7-3/16
(183)
8-7/64
(206)
6-3/4
(171)
5-55/64
(149)
6-1/8
(155)
6-1/8
(155)
7/8
(22)
5/16
(8)
7-3/16
(183)
1497B-A3-M13-0-N
1497B-A3-M14-0-N
5 (2.3)
1497B-A3-M16-0-N
1497B-A3-M17-0-N
1497B-A4-M13-0-N
150
1497B-A4-M14-0-N
1497B-A4-M16-0-N
1497B-A4-M17-0-N
1497B-A5-M11-0-N
200
1497B-A5-M12-0-N
1497B-A5-M13-0-N
1497B-A6-M13-0-N
250
1497B-A6-M14-0-N
1497B-A6-M16-0-N
1497B-A6-M17-0-N
1497B-A7-M11-0-N
300
1497B-A7-M12-0-N
1497B-A7-M13-0-N
1497B-A9-M11-0-N
500
1497B-A9-M12-0-N
1497B-A9-M14-0-N
1497B-A9-M15-0-N
1497B-A10-M12-0-N
750
1497B-A10-M14-0-N
1497B-A10-M15-0-N
1497B-A11-M11-0-N
1000
1497B-A11-M12-0-N
1497B-A11-M14-0-N
1497B-A11-M15-0-N
1500
1497B-A12-M14-0-N
1497B-A12-M15-0-N
1497B-A13-M11-0-N
1497B-A13-M12-0-N
2000 1497B-A13-M14-0-N
10
1497B-A13-M15-0-N
40 (18.1)
41 (18.6)
61 (27.7)
8-7/64
(206)
9
(229)
53 (24)
6-3/4
(171)
5-55/64
(149)
6-1/8
(155)
6-1/8
(155)
7/8
(22)
5/16
(8)
7-3/16
(183)
9
(229)
7-41/64
(194)
5-13/16
(148)
7-1/2
(191)
9/10
(23)
7/16
(11)
8-61/64
(227)
53 (24)
8-7/64
(206)
1497B-A14-M11-0-N
3000
11
1497B-A14-M12-0-N
1497B-A14-M14-0-N
8-9/16
(217)
1497B-A14-M15-0-N
12
13
www.ab.com/catalogs
8-58
Publication A117-CA001A-EN-P
78 (35.4)
Bulletin 1497D
Table of Contents
Standards Compliance
0
1
Certifications
UL Listed (File No. E311296;
Guide No. XQNX)
CSA Certified
Your order must include the cat. no. of the control circuit transformer selected.
1497D A1 M10 0 N
a
VA Rating
Code
Description [VA]
Code
Primary
Secondary
Code
Block Options
A1
50
M10
240X480V
0 Primary, 0 Secondary
A2
75
M11
600V
A3
100
M14
240X480V
A4
150
120/240V
(50/60 Hz)
A6
250
M20
208V
Code
Description
480V
22
No taps
A9
500
M21
A10
750
M22
480V
A11
1000
120/240V
(50/60 Hz)
A12
1500
M23
600V
120/240V
(50/60 Hz)
A13
2000
M24
480V
A14
3000
A15
5000
A16
7500
A17
10000
A18
15000
A20
25000
d
Factory Installed Options
7
8
9
Note: For complete list of valid transformer configurations, see Product Selection.
10
11
12
13
www.ab.com/catalogs
Publication A117-CA001A-EN-P
8-59
Bulletin 1497D
Secondary 120/240V
Continuous kVA
SECONDARY
1
BOTTOM VIEW
2
Primary 208V
Cat. No.
1497D-A1-M20-0-N
0.075
1497D-A2-M20-0-N
0.100
1497D-A3-M20-0-N
0.150
1497D-A4-M20-0-N
0.250
1497D-A6-M20-0-N
0.500
1497D-A9-M20-0-N
0.750
1497D-A10-M20-0-N
60
1.5
Temp. Rise
[C (F)]
0.050
1.0
PRIMARY
Frequency [Hz]
115 (239)
1497D-A11-M20-0-N
1497D-A12-M20-0-N
2.0
1497D-A13-M20-0-N
3.0
1497D-A14-M20-0-N
5.0
1497D-A15-M20-0-N
7.5
1497D-A16-M20-0-N
Winding
Voltage
Accuracy
[V]
Connect
Line
10.0
1497D-A17-M20-0-N
Primary
208
H1-H2
15.0
1497D-A18-M20-0-N
240
X2-X3
X1-X4
25.0
1497D-A20-M20-0-N
240/1201
X2-X3
X1-X3-X4
120
X1X3-X2X4
X1-X4
Secondary
Continuous kVA
SECONDARY
0.050
0.075
BOTTOM VIEW
0.100
PRIMARY
0.150
Primary 240x480V
8
Winding
Primary
9
Secondary
10
Voltage
Accuracy
[V]
Connect
Line
480
H2-H3
H1-H4
240
H1H3H2H4
H1-H4
0.250
0.500
0.750
1497D-A1-M10-0-N
50/60
1497D-A1-M14-0-N
60
1497D-A2-M10-0-N
50/60
1497D-A2-M14-0-N
60
1497D-A3-M10-0-N
50/60
1497D-A3-M14-0-N
60
1497D-A4-M10-0-N
50/60
1497D-A4-M14-0-N
60
1497D-A6-M10-0-N
50/60
1497D-A6-M14-0-N
60
1497D-A9-M10-0-N
50/60
1497D-A9-M14-0-N
60
1497D-A10-M10-0-N
1497D-A10-M14-0-N
240
X2-X3
X1-X4
X2-X3
X1-X3-X4
60
1497D-A11-M10-0-N
120
X1X3-X2X4
X1-X4
50/60
1497D-A11-M14-0-N
1.0
1.5
3.0
11
5.0
7.5
10.0
15.0
25.0
www.ab.com/catalogs
8-60
Cat. No.
60
240/1201
2.0
13
Temp. Rise
[C (F)]
50/60
12
Frequency [Hz]
60
115 (239)
1497D-A12-M10-0-N
50/60
1497D-A12-M14-0-N
60
1497D-A13-M10-0-N
50/60
1497D-A13-M14-0-N
60
1497D-A14-M10-0-N
50/60
1497D-A14-M14-0-N
60
1497D-A15-M10-0-N
50/60
1497D-A15-M14-0-N
60
1497D-A16-M10-0-N
50/60
1497D-A16-M14-0-N
60
1497D-A17-M10-0-N
50/60
1497D-A17-M14-0-N
60
1497D-A18-M10-0-N
50/60
1497D-A18-M14-0-N
60
1497D-A20-M10-0-N
50/60
1497D-A20-M14-0-N
Publication A117-CA001A-EN-P
Bulletin 1497D
SECONDARY
BOTTOM VIEW
Frequency [Hz]
0.050
1497D-A1-M21-0-N
1497D-A2-M21-0-N
0.100
1497D-A3-M21-0-N
0.150
1497D-A4-M21-0-N
0.250
1497D-A6-M21-0-N
Primary 480V
60
115 (239)
1497D-A10-M21-0-N
1.0
1497D-A11-M21-0-N
1.5
1497D-A12-M21-0-N
2.0
1497D-A13-M21-0-N
Winding
Connect
Line
3.0
1497D-A14-M21-0-N
Primary
480
H1-H2
5.0
1497D-A15-M22-0-N
240
X2-X3
X1-X4
7.5
1497D-A16-M22-0-N
240/1201
X2-X3
X1-X3-X4
10.0
120
X1X3-X2X4
X1-X4
15.0
1497D-A18-M22-0-N
25.0
1497D-A20-M22-0-N
50/60
115 (239)
Secondary 208V
Continuous kVA
Frequency [Hz]
0.075
1497D-A2-M24-0-N
0.100
1497D-A3-M24-0-N
0.150
1497D-A4-M24-0-N
0.250
1497D-A6-M24-0-N
0.500
1497D-A9-M24-0-N
0.750
1497D-A10-M24-0-N
1.0
1497D-A11-M24-0-N
115 (239)
3
4
Cat. No.
1497D-A1-M24-0-N
60
1497D-A17-M22-0-N
0.050
1.5
Primary 480V
Temp. Rise
[C (F)]
1497D-A9-M21-0-N
0.750
Voltage
Accuracy
[V]
Secondary
Cat. No.
0.075
0.500
PRIMARY
Temp. Rise
[C (F)]
5
6
1497D-A12-M24-0-N
2.0
1497D-A13-M24-0-N
3.0
1497D-A14-M24-0-N
5.0
1497D-A15-M24-0-N
7.5
1497D-A16-M24-0-N
10.0
1497D-A17-M24-0-N
15.0
1497D-A18-M24-0-N
25.0
1497D-A20-M24-0-N
7
8
SECONDARY
Temp. Rise
[C (F)]
Tap Quantity
0.500
50/60
1497D-A9-M22-0-2
1497D-A10-M22-0-2
0.750
BOTTOM VIEW
1.0
1.5
PRIMARY
2.0
Primary 480V
Winding
Primary
Secondary
Voltage
Accuracy
[V]
Connect
Line
480
H1-H4
5.0
456
H2-H4
7.5
432
H2-H3
10.0
3.0
Cat. No.
1497D-A6-M22-0-2
0.250
60
1497D-A11-M21-0-2
50/60
1497D-A11-M22-0-2
60
1497D-A12-M21-0-2
50/60
1497D-A12-M22-0-2
60
50/60
115 (239)
(2) 5% FCBN
1497D-A13-M21-0-2
1497D-A13-M22-0-2
60
1497D-A14-M21-0-2
50/60
1497D-A14-M22-0-2
1497D-A15-M21-0-2
1497D-A16-M21-0-2
60
10
11
12
1497D-A17-M21-0-2
240
X2-X3
X1-X4
15.0
1497D-A18-M21-0-2
240/1201
X2-X3
X1-X3-X4
25.0
1497D-A20-M21-0-2
120
X1X3-X2X4
X1-X4
13
www.ab.com/catalogs
Publication A117-CA001A-EN-P
8-61
Bulletin 1497D
Secondary 120/240V
Continuous kVA Frequency [Hz]
SECONDARY
BOTTOM VIEW
5.0
1497D-A15-M21-0-22
60
10.0
115 (239)
Winding
Primary
4
Secondary
1497D-A16-M21-0-22
1497D-A17-M21-0-22
15.0
1497D-A18-M21-0-22
25.0
1497D-A20-M21-0-22
Voltage
Accuracy
[V]
Connect
Line
504
H1-H5
492
H1-H4
480
H1-H3
468
H2-H4
456
H2-H3
240
X2-X3
X1-X4
240/1201
X2-X3
X1-X3-X4
120
X1X3-X2X4
X1-X4
SECONDARY
0.050
0.075
0.100
0.150
BOTTOM VIEW
0.250
0.500
PRIMARY
0.750
Primary 600V
Frequency [Hz]
Temp. Rise
[C (F)]
Cat. No.
1497D-A1-M11-0-N
60
1497D-A2-M11-0-N
60
1497D-A3-M11-0-N
50/60
1497D-A3-M23-0-N
60
1497D-A4-M11-0-N
60
1497D-A6-M11-0-N
50/60
1497D-A6-M23-0-N
60
1497D-A9-M11-0-N
50/60
1497D-A9-M23-0-N
60
1497D-A10-M11-0-N
50/60
115 (239)
1497D-A10-M23-0-N
1.0
1497D-A11-M11-0-N
1.5
1497D-A12-M11-0-N
1497D-A13-M11-0-N
Winding
Voltage
Accuracy
[V]
Connect
Line
2.0
Primary
600
H1-H2
3.0
240
X2-X3
X1-X4
5.0
240/1201
X2-X3
X1-X3-X4
7.5
1497D-A16-M11-0-N
120
X1X3-X2X4
X1-X4
10.0
1497D-A17-M11-0-N
15.0
1497D-A18-M11-0-N
25.0
1497D-A20-M11-0-N
Secondary
10
Primary 480V
Cat. No.
1497D-A14-M21-0-22
PRIMARY
Tap Quantity
3.0
7.5
Temp. Rise
[C (F)]
1497D-A14-M11-0-N
60
11
12
13
www.ab.com/catalogs
8-62
Publication A117-CA001A-EN-P
1497D-A15-M11-0-N
Bulletin 1497D
SECONDARY
0.250
0.500
1.0
BOTTOM VIEW
1.5
2.0
PRIMARY
3.0
Primary 600V
Winding
Primary
Secondary
Temp. Rise
[C (F)]
0
Tap Quantity
1497D-A6-M23-0-2
50/60
1497D-A9-M23-0-2
60
1497D-A11-M11-0-2
50/60
1497D-A11-M23-0-2
60
Connect
Line
600
H1-H2
570
H1-H3
540
H2-H3
240
X2-X3
X1-X4
240/1201
X2-X3
X1-X3-X4
120
X1X3-X2X4
X1-X4
7.5
(2) 5% FCBN
1497D-A13-M11-0-2
60
1497D-A14-M11-0-2
50/60
1497D-A14-M23-0-2
1497D-A15-M11-0-2
1497D-A16-M11-0-2
60
10.0
1497D-A17-M11-0-2
3
4
600V Primary with Four 2.5% Taps Below Rated Primary Volts
Secondary 120/240V
Continuous kVA Frequency [Hz]
SECONDARY
1497D-A12-M11-0-2
115 (239)
5.0
Voltage
Accuracy
[V]
Cat. No.
15.0
25.0
60
5
Temp. Rise
[C (F)]
115 (239)
Tap Quantity
(4) 2.5% FCBN
Cat. No.
1497D-A18-M11-0-4
1497D-A20-M11-0-4
BOTTOM VIEW
7
PRIMARY
Primary 600V
Winding
Primary
Secondary
Voltage
Accuracy
[V]
Connect
Line
600
H1-H5
585
H1-H4
570
H1-H3
555
H2-H4
540
H2-H3
240
X2-X3
X1-X4
240/1201
X2-X3
X1-X3-X4
120
X1X3-X2X4
X1-X4
9
10
11
12
13
www.ab.com/catalogs
Publication A117-CA001A-EN-P
8-63
Bulletin 1497D
DIA.
R.
3 TOTAL
2 TOTAL
1
N.
P.
COMP.
WIRE
2
1/2 KO
4 TOTAL
3
4
Copper
M10, M20,
M21, M24
3-31/32
(101)
3-9/16
(90)
6-23/64
(162)
7-17/64
(185)
1-1/2
(38)
2-61/64
(75)
8-29/32
(226)
4
(102)
1-47/64
(44)
1-49/64
(45)
1-2/3
(42)
1-3/8
(35)
8
(4)
M14
3-31/32
(101)
3-9/16
(90)
6-23/64
(162)
7-3/8
(187)
1-1/2
(38)
2-61/64
(75)
8-29/32
(226)
4
(102)
1-47/64
(44)
1-49/64
(45)
1-2/3
(42)
1-3/8
(35)
8
(4)
M11
3-31/32
(101)
3-9/16
(90)
6-23/64
(162)
7-17/64
(185)
1-1/2
(38)
2-61/64
(75)
8-29/32
(226)
4
(102)
1-47/64
(44)
1-49/64
(45)
1-2/3
(42)
1-3/8
(35)
8
(4)
75
(A2)
M10, M11,
M14, M20,
M21, M24
3-31/32
(101)
3-9/16
(90)
6-23/64
(162)
7-17/64
(185)
1-1/2
(38)
2-61/64
(75)
8-29/32
(226)
4
(102)
1-47/64
(44)
1-49/64
(45)
1-2/3
(42)
1-3/8
(35)
8
(4)
100
(A3)
M10, M11,
M14, M20,
M21, M23,
M24
3-31/32
(101)
3-9/16
(90)
6-23/64
(162)
7-17/64
(185)
1-1/2
(38)
2-61/64
(75)
8-29/32
(226)
4
(102)
1-47/64
(44)
1-49/64
(45)
1-2/3
(42)
1-3/8
(35)
8
(4)
150
(A4)
M10, M11,
M20, M21,
M24
3-31/32
(101)
3-9/16
(90)
6-23/64
(162)
7-17/64
(185)
1-1/2
(38)
2-61/64
(75)
8-29/32
(226)
4
(102)
1-47/64
(44)
1-49/64
(45)
1-2/3
(42)
1-3/8
(35)
8
(4)
VA
(Code)
5
6
7
Approximate
Shipping Wt.
lb (kg)
Primary and
Secondary
Voltage
Code
50
(A1)
DIA.
R.
3 TOTAL
2 TOTAL
8
N.
P.
WIRE
10
COMP.
1/2, 3/4 KO
6 TOTAL
11
VA
(Code)
12
150
(A4)
250
(A6)
13
500
(A9)
Primary and
Secondary
Voltage
M14
M10, M11,
M14, M20,
M21, M22,
M23, M24
M10, M11,
M14, M20,
M21, M23,
M24
Approximate
Shipping Wt.
lb (kg)
A
Copper
4-39/64
(117)
3-33/64
(89)
6-5/16
(160)
7-1/4
(184)
1-3/8
(35)
2-5/32
(55)
8-31/32
(228)
4-1/6
(103)
15/16
(24)
2-9/16
(65)
2-1/2
(64)
1-53/64
(46)
1-3/8
(35)
15
(6)
4-39/64
(117)
3-33/64
(89)
6-5/16
(160)
7-1/4
(184)
1-3/8
(35)
2-5/32
(55)
8-31/32
(228)
4-1/16
(103)
15/16
(24)
2-9/16
(65)
2-33/64
(64)
1-53/64
(46)
1-3/8
(35)
15
(6)
4-39/64
(117)
4-23/64
(111)
6-5/16
(160)
7-1/4
(184)
1-3/8
(35)
2-5/32
(55)
8-31/32
(228)
4-29/32
(125)
1-3/8
(35)
3
(76)
3-3/8
(86)
1-53/64
(46)
1-3/8
(35)
16
(7)
www.ab.com/catalogs
8-64
Publication A117-CA001A-EN-P
Bulletin 1497D
0
R.
DIA.
3 TOTAL
2 TOTAL
1
N.
3/4, 1-1/4 KO
2 TOTAL
P.
2
COMP.
WIRE
3
1/2, 3/4 KO
6 TOTAL
4
Primary
and
VA
Secondary
(Code)
Voltage
Approximate
Shipping Wt.
lb (kg)
A
Copper
500
(A9)
M22, M23
547/64
(146)
515/64
(133)
8-5/8
(219)
9-35/64
(243)
1-5/8
(41)
247/64
(69)
119/32
(287)
5-3/4
(146)
1-1/2
(38)
3-3/4
(95)
4-1/4
(108)
1-3/8
(35)
153/64
(46)
7/8
(22)
24
(11)
750
(A10)
M11, M21
547/64
(146)
515/64
(133)
8-5/8
(219)
9-35/64
(243)
1-5/8
(41)
247/64
(69)
119/32
(287)
5-3/4
(146)
1-1/2
(38)
3-3/4
(95)
4-1/4
(108)
1-3/8
(35)
153/64
(46)
7/8
(22)
24
(11)
750
(A10)
M10, M14,
M20, M22,
M23, M24
547/64
(146)
515/64
(133)
8-5/8
(219)
9-35/64
(243)
1-5/8
(41)
247/64
(69)
119/32
(287)
5-3/4
(146)
1-1/2
(38)
3-3/4
(95)
4-1/4
(108)
1-3/8
(35)
153/64
(46)
7/8
(22)
36
(16)
M10, M11,
M14, M20,
M21, M24
547/64
(146)
515/64
(133)
8-5/8
(219)
9-35/64
(243)
1-5/8
(41)
247/64
(69)
119/32
(287)
5-3/4
(146)
1-1/2
(38)
3-3/4
(95)
4-1/4
(108)
1-3/8
(35)
153/64
(46)
7/8
(22)
36
(16)
1000
(A11)
M22, M23
6-1/10
(155)
6
(152)
10-3/4 11-49/64
(273)
(299)
1-3/4
(44)
3
(76)
1313/32
(341)
633/64
(166)
1-7/8
(48)
4-1/8
(105)
453/64
(122)
1-3/8
(35)
153/64
(46)
1
(25)
50
(23)
1500
(A12)
M10, M11,
M14, M20, 6-1/10
M21, M22, (155)
M24
6
(152)
10-3/4 11-49/64
(273)
(299)
1-3/4
(44)
3
(76)
1313/32
(341)
633/64
(166)
1-7/8
(48)
4-1/8
(105)
453/64
(122)
1-3/8
(35)
153/64
(46)
1
(25)
50
(23)
2000
(A13)
M10, M11,
6-1/10
M14, M20,
(155)
M21, M24
6
(152)
10-3/4 11-49/64
(273)
(299)
1-3/4
(44)
3
(76)
1313/32
(341)
633/64
(166)
1-7/8
(48)
4-1/8
(105)
453/64
(122)
1-3/8
(35)
153/64
(46)
1
(25)
50
(23)
1 1000
(A11)
5
6
7
8
9
10
11
12
13
www.ab.com/catalogs
Publication A117-CA001A-EN-P
8-65
Bulletin 1497D
0
N.
WIRING
COMPARTMENT
R.
P.
R.
2 TOTAL
R.
M
DOUBLE K.O.
4 TOTAL
VIEW A
SEE VIEW A
VA
(Code)
Primary
and
Secondary
Voltage
Approximate
Shipping Wt.
lb (kg)
M22
14-1/4
(362)
7-11/16
(195)
8
(203)
7-15/16
(202)
4-1/6
(103)
11-1/16
(281)
1-5/8
(41)
13
(330)
5/8
(16)
2-1/4
(57)
1-3/4
(44)
1/2, 3/4
(13, 19)
2-1/2
(64)
3-21/64
(84)
69
(31)
M10, M11,
M20, M21,
M24
14-1/4
(362)
7-11/16
(195)
8
(203)
7-15/16
(202)
4-1/6
(103)
11-1/16
(281)
1-5/8
(41)
13
(330)
5/8
(16)
2-1/4
(57)
1-3/4
(44)
1/2, 3/4
(13, 19)
2-1/2
(64)
3-21/64
(84)
65
(30)
2000
(A13)
3000
(A14)
Copper
Aluminum
SEE VIEW A
5
N.
P.
WIRING
COMPARTMENT
R.
R.
2 TOTAL
R.
M
DOUBLE K.O.
4 TOTAL
VIEW A
8
VA
(Code)
9
10
11
12
13
Primary and
Secondary
Voltage
Approx.
Shipping
Wt.
lb (kg)
A
Aluminum
3-15/32
(88)
3-39/64
(92)
113
(51)
3000
(A14)
M14, M22,
M23
16
(406)
10-3/8
(264)
9-57/64
(251)
9-4/5
(249)
5-1/6
(129)
12-53/64
(326)
1-5/8
(41)
14-3/4
(375)
5/8
(16)
3
(76)
1-7/8
(48)
3/4, 1-1/4
(19, 32)
3/4, 11/4
(19, 32)
5000
(A15)
M10, M11,
M20, M21,
M24
16
(406)
10-3/8
(264)
9-57/64
(251)
9-4/5
(249)
5-1/6
(129)
12-53/64
(326)
1-5/8
(41)
14-3/4
(375)
5/8
(16)
3
(76)
1-7/8
(48)
3/4, 1-1/4
(19, 32)
3/4, 11/4
(19, 32)
3-15/32
(88)
3-39/64
(92)
113
(51)
5000
(A15)
M14, M22
16
(406)
10-3/8
(264)
9-57/64
(251)
9-4/5
(249)
5-1/6
(129)
12-53/64
(326)
1-5/8
(41)
14-3/4
(375)
5/8
(16)
3
(76)
1-7/8
(48)
3/4, 1-1/4
(19, 32)
2-1/2
(64)
3-15/32
(88)
3-39/64
(92)
123
(55)
7500
(A16)
M10, M11,
M20, M21,
M24
16
(406)
10-3/8
(264)
9-57/64
(251)
9-4/5
(249)
5-1/6
(129)
12-53/64
(326)
1-5/8
(41)
14-3/4
(375)
5/8
(16)
3
(76)
1-7/8
(48)
3/4, 1-1/4
(19, 32)
2-1/2
(64)
3-15/32
(88)
3-39/64
(92)
123
(55)
7500
(A16)
M14, M22
19
(483)
13-3/8
(340)
10-33/64
(267)
10-15/32
(266)
5-7/6
(138)
15-53/64
(402)
1-5/8
(41)
17-3/4
(451)
5/8
(16)
3-3/8
(86)
1-7/8
(48)
3/4, 1-1/4
(19, 32)
2-1/2
(64)
3-15/32
(88)
1, 11/2
(25,
38)
3-3/4
(95)
193
(87)
10000
(A17)
M10, M11,
M20, M21,
M24
19
(483)
13-3/8
(340)
10-33/64
(267)
10-15/32
(266)
5-7/6
(138)
15-53/64
(402)
1-5/8
(41)
17-3/4
(451)
5/8
(16)
3-3/8
(86)
1-7/8
(48)
3/4, 1-1/4
(19, 32)
2-1/2
(64)
3-15/32
(88)
1, 11/2
(25,
38)
3-3/4
(95)
193
(87)
10000
(A17)
M14, M22
19
(483)
13-3/8
(340)
10-33/64
(267)
10-15/32
(266)
5-7/6
(138)
15-53/64
(402)
1-5/8
(41)
17-3/4
(451)
5/8
(16)
3-3/8
(86)
1-7/8
(48)
3/4, 1-1/4
(19, 32)
2-1/2
(64)
3-15/32
(88)
1, 11/2
(25,
38)
3-3/4
(95)
216
(98)
15000
(A18)
M10, M11,
M20, M21,
M22
19
(483)
13-3/8
(340)
10-33/64
(267)
10-15/32
(266)
5-7/6
(138)
15-53/64
(402)
1-5/8
(41)
17-3/4
(451)
5/8
(16)
3-3/8
(86)
1-7/8
(48)
3/4, 1-1/4
(19, 32)
2-1/2
(64)
3-15/32
(88)
1, 11/2
(25,
38)
3-3/4
(95)
216
(98)
www.ab.com/catalogs
8-66
Publication A117-CA001A-EN-P
Bulletin 1497D
0
Cat. No. 1491-R150
Fuse Cover without Fuse
N.
WIRING
COMPARTMENT
SEE VIEW A
P.
R.
R.
R.
M
SINGLE K.O.
4 TOTAL
VIEW A
4
VA
(Code)
Primary and
Secondary Voltage
15000
(A18)
25000
(A20)
M14, M22
23-5/16
(592)
16-11/32
(415)
14- 1/8
(359)
14-1/16
(357)
7-25/64
(188)
18-1/16
(459)
2-19/32
(66)
22
(558)
3/4
(19)
3-7/16
(87)
2-7/16
(62)
23-5/16
(592)
16-11/32
(415)
14- 1/8
(359)
14-1/16
(357)
7-25/64
(188)
18-1/16
(459)
2-19/32
(66)
22
(558)
3/4
(19)
3-7/16
(87)
2-7/16
(62)
VA
(Code)
Primary and
Secondary Voltage
15000
(A18)
25000
(A20)
Aluminum
M14, M22
2
(51)
2-7/16
(62)
4
(102)
4-7/16
(113)
2
(51)
21/32
(17)
375
(170)
2
(51)
2-7/16
(62)
4
(102)
4-7/16
(113)
2
(51)
21/32
(17)
375
(170)
5
6
7
8
9
10
11
12
13
www.ab.com/catalogs
Publication A117-CA001A-EN-P
8-67
Bulletin 1497
0
1
2
3
Cat. No. 1491-R165
1-Pole Fuse Block
4
5
6
7
8
These control circuit fusing kits are intended to be used for control circuit transformer protection and protection of control circuits capable of
delivering no more than 200 000 RMS symmetrical amps, 600V maximum.
Description1
9
10
11
12
Cat. No.
1491-R150
1491-R165
1491-R162
1491-R167
1491-R169
1491-R171
599-FR04
1491-R173
1491-R175
1 For control circuit transformers with a 350VA or larger rating, it is recommended that Bussmann Type FNQ-R, Ferraz-Shawmut Type ATDR, Littelfuse Type
13
www.ab.com/catalogs
8-68
Publication A117-CA001A-EN-P
Bulletin 1497
Nameplate
1-5/16
(33.27)
Ref.
0
1-5/16
(33.27)
Ref.
1-5/8
(41.15)
Ref.
3
(76.20)
1-5/8
(41.15)
Ref.
3
(76.20)
16/93
(4.37) Dia.
2 Holes
Ref.
Fuse
Block
3/8
(9.52)
5/16
(7.92)
3/4
(19.05)
Ref.
3
(76.20)
1-1/2
(38.10)
55/64
(21.84)
1-1/2
(38.10)
27/64
(10.92)
3
(76.20)
27/64
(10.92)
3/4
(19.05)
3/4
(19.05)
3/4
(19.05)
3/4
(19.05)
This Clip to be
for Std. Fuse
(Midget), not
Class CC
(Rejection)
4
5
1-5/16
7
2-23/64
5/16
3-45/64
21/32
(16.67)
9
10
21/32
(16.67)
11
12
13
www.ab.com/catalogs
Publication A117-CA001A-EN-P
8-69
Power Monitoring
Product Overview
Powermonitor Products
0
1
8-71, 8-73,
and 8-76
8-71, 8-73,
and 8-77 871, 7-6, and
8-76
8-71, 8-74,
and 8-77
8-71, 8-75,
and 8-78
8-71, 8-75,
and 8-80
8-72, 8-75,
and 8-80
2
3
4
5
See Page
7
8
9
10
11
12
13
www.ab.com/catalogs
8-70
Publication A117-CA001A-EN-P
Power Monitoring
Product Overview
Powermonitor 3000 Products (Bulletin 1404)
The Powermonitor 3000 has four versions, the M4, M5, M6, and the
M8. The M4 unit provides basic metering including frequency,
voltage, current, and power. It also provides calculated information
such as energy consumption, power factor, and total harmonic
distortion. The unit also has onboard logging capability that can
store data, record the min and max of each parameter, and keep an
event log.
0
1
2
3
4
9
10
11
12
13
www.ab.com/catalogs
Publication A117-CA001A-EN-P
8-71
Power Monitoring
Product Overview
0
1
2
3
4
5
6
9
10
11
12
13
www.ab.com/catalogs
8-72
Publication A117-CA001A-EN-P
Power Monitoring
Specifications
Powermonitor 3000
Environmental
1404-MX05X-000, DNT,
20+60 C (4+140 F)
Operating
1404-DM
Temperature,
1404-MX05X-RIO,
Ambient
055 C (32132 F)
RS232, ENT
Storage Temperature
40+85 C (40+185 F)
Humidity
595% non-condensing
operational: 2 g (0.012 in.)
Vibration
10500 Hz
non-operational: 2.5 g (0.015 in.)
1/2 sine pulse,
operational: 30 g
Shock
11 ms duration
non-operational: 30 g
Voltage
Current
Frequency
Voltage
Current
Frequency
Power
Energy
Features
Configurable Setpoints
Waveform Captures
Harmonic Analysis
Order
%THD
TIF
K-factor
Crest factor
IEEE 519 Compliance
Transient Detection
Range
15399V L-N rms
26691V L-L rms
5A
50 or 60 Hz
50 mA10.6 A rms
4075 Hz
10
20
8
20
2
41st
X
X
X
X
X
63rd
X
X
X
X
X
X
Powermonitor 1000
General Specifications
Dielectric withstand
Terminal Blocks
Operating Temperature
Storage Temperature
Control power
2500V
Voltage inputs
2500V
Current inputs
2500V
Status inputs
2500V
KYZ output
2500V
Vibration
2.0 g 10500 Hz
Shock
www.ab.com/catalogs
Parameter
Voltage Sense
Inputs:
V1, V2, V3
0.5%
Current Sense
Input:
I1, I2, I3, I4
0.5%
0.05 Hz
Frequency
Power
Functions:
kW, kVA, kVAR
EN62053-21:20
Demand
03 Accuracy
Functions:
Requirement
kW, kVA
Class 1
Energy
Functions:
kWH, kVAH
Metering
100 ms: V, I, Hz
Update Rates 200 ms: Power
kWh
only
0
1
2
Nominal/
Range
347V/
15399V
L-N rms
600V/
26691V
L-L rms
5 A/
0.051.0 A
rms
50 or 60 Hz/
4075 Hz
3
4
5
6
7
-40+85 C (-40+185 F)
Humidity
TR1
TR2
Energy Log
Minimum/Maximum Log
Load Factor Log
Status Log
EM1
X
EM2
X
X
X
X
EM3
X
X
X
X
X
X
X
X
X
X
X
X
X
9
10
11
12
EM2
X
X
X
X
EM3
X
X
X
X
13
Publication A117-CA001A-EN-P
8-73
Power Monitoring
Specifications
PowerPad Portable Powermonitor
Electrical
Sampling Frequency
Data Storage
Voltage (TRMS)
Current (TRMS)
Measurement
Range
Resolution
Accuracy
6480V
0.1V
0.5% 2cts
10830V
0.1V
0.5% 2cts
6680V
1V
(1% 5cts)
101360V
1V
(1% 5cts)
Frequency (Hz)
4069 Hz
0.01 Hz
0.01 Hz
6650V
0.1V
1% 2cts
0240 A
01200 A
106500 A
0.1 A
0.1 A; 11000 A
0.1 A; 11000 A
(0.5% + 2 cts)
(0.5% + 2 cts)
(0.5% + 1 A)
09999 kW
1% 1ct @ PF 0.8
09999 kVAR
1% 1ct @ PF 0.8
09999 kVA
1% 1ct
-1.0001.000
0.001
(1.5% + 0.01)
09999 MWh
1% 1ct @ PF 0.8
09999 MVARh
1% 1ct @ PF 0.8
09999 MVAh
1% 1ct
0100%
0.1%
1% 1ct
-179180
2 1ct
Unbalance (V & A)
Phase Angles (V-A, A-A, V-V)
Harmonics (150)
F=4069Hz (V 50V, A > Inom/100
0999%
0.1%
1% + 5ct
0999%
0.1%
1% + 5ct
199.99
0.01
5% 1ct
0.009.99
0.01
K-factor (Akf)
Flicker (Pst)
Power Source
Battery Life
6 hours with display on; 96 hrs with display off (record mode)
Environmental
Operating Temperature
050 C (32122 F)
Storage Temperature
-20+50 C (-4+122 F)
Mechanical
Display
Dimensions
Weight
Safety Rating
10
DC Voltage Component
Double Insulation
Yes
CE Mark
Yes
11
12
13
www.ab.com/catalogs
8-74
Publication A117-CA001A-EN-P
Power Monitoring
Specifications
Current Transformers
Core Type
Split or solid
Current Ratio
Range
50:56000:5
Burden Range
1200 VA
Window Sizes
Certifications
No. of
Wiring
Phases Configuration
Permanent
Magnet
Generator
PMG-A &
PMG-C
Floating wye
PMG-A &
PMG-C
Floating wye
Grounded
wye
(grounded
neutral)
UL, CSA
Standards
RSPower Software
System Hardware Requirements
Compatible
Microprocessor
RAM
Hard Disk
Drive
Pentium 4 or P4
256 MB
Frequency
1
Min: 50 Hz
Max: 342 Hz
Operating
System
2
3
No. of
Wiring
Phases Configuration
Grounded
Connection
Available
Voltage
VA & VC
No
Communication
Type
Floating wye
No
Communication
Interface
Grounded wye
Yes
Open delta,
grounded "B"
phase
Yes
External
Connections
3070
CD-ROM/DVD-ROM
3.5 inch, 1.44 MB
Devices
VA
(max.)
Disk Drive
Application
Voltage
Frequency
Min: 20 Hz
Max: 90 Hz
4
5
6
Frequency
50/60 Hz
Range
1 or 5 A maximum continuous
Burden
3 Phase
7
8
Field Output
Continuous
Voltage
Continuous
Current
15 A DC
10 second
Forcing Voltage
10 second
Forcing
Current
10
11
12
13
www.ab.com/catalogs
Publication A117-CA001A-EN-P
8-75
Power Monitoring
Product Selection
Powermonitor 3000 (Bulletin 1404)
(1404-M4, M5, M6, and M8) 120/240 Volt Power Supply Option
Description
M4 Monitors
RS-485
2
3
1404-M405A-000
5
6
1404-M505A-CNT-02
1404-M405A-DNT
1404-M505A-DNT-02
1404-M405A-RIO
1404-M505A-RIO-02
1404-M405A-ENT
1404-M505A-ENT-02
RS-485
1404-M505A-000
RS-485
1404-M505A-232
1404-M505A-CNT
1404-M505A-DNT
M5 Monitors
M6 Monitors
1404-M505A-RIO
1404-M505A-ENT
1404-M605A-232-02
1404-M605A-CNT-02
1404-M605A-DNT-02
1404-M605A-RIO-02
1404-M605A-ENT-02
M8 Monitors
1404-M605A-000
1404-M605A-232
RS-485
1404-M605A-CNT
1404-M805A-232-02
1404-M605A-DNT
1404-M805A-CNT-02
1404-M805A-DNT-02
1404-M605A-RIO
1404-M605A-ENT
M8 Monitors
RS-485
1404-M805A-000
1404-M805A-232
1404-M805A-CNT
1404-M805A-DNT
1404-M805A-RIO
1404-M805A-ENT
Description
Cat. No.
M4 Monitors
1404-M405B-000
1404-M805A-000-02
1404-M805A-RIO-02
1404-M805A-ENT-02
Cat. No.
M5 Monitors
RS-485
1404-M505B-000-02
1404-M505B-232-02
1404-M505B-CNT-02
1404-M505B-DNT-02
1404-M505B-RIO-02
1404-M505B-ENT-02
M6 Monitors
1404-M405B-232
1404-M405B-CNT
RS-485
1404-M405B-DNT
1404-M605B-232-02
1404-M405B-RIO
1404-M605B-CNT-02
1404-M605B-DNT-02
1404-M405B-ENT
M5 Monitors
RS-485
1404-M505B-000
1404-M605B-000-02
1404-M605B-RIO-02
1404-M605B-ENT-02
1404-M505B-232
1404-M505B-CNT
1404-M505B-DNT
RS-485
1404-M505B-RIO
1404-M805B-232-02
1404-M505B-ENT
1404-M805B-CNT-02
1404-M805B-DNT-02
M6 Monitors
RS-485
1404-M605B-000
1404-M605B-232
1404-M605B-CNT
1404-M605B-DNT
1404-M605B-RIO
1404-M605B-ENT
M8 Monitors
RS-485
12
1404-M605A-000-02
RS-485
11
1404-M505A-232-02
1404-M405A-232
RS-485
10
1404-M505A-000-02
1404-M405A-CNT
RS-485
Cat. No.
M5 Monitors
M6 Monitors
Description
1404-DM
Cat. No.
1404-M805B-000
1404-M805B-232
1404-M805B-CNT
1404-M805B-DNT
1404-M805B-RIO
1404-M805B-ENT
M8 Monitors
1404-M805B-000-02
1404-M805B-RIO-02
1404-M805B-ENT-02
Cat. No.
40863-600-51
40863-600-52
40863-600-53
13
www.ab.com/catalogs
8-76
Publication A117-CA001A-EN-P
Power Monitoring
Product Selection
Powermonitor 1000 (Bulletin 1408)
Description
Cat. No.
1408-TR1A-485
1408-TR1A-ENT
1408-TR2A-485
1408-TR2A-ENT
1408-EM1A-485
1408-EM1A-ENT
1408-EM2A-485
1408-EM2A-ENT
1408-EM3A-485
1408-EM3A-ENT
1
2
Cat. No.
1408-UP485-ENT
1408-UPE1-E3
1408-UPE2-E3
1408-UPT1-E3
1408-UPT2-E3
3
4
Cat. No.
1412-PP2127-48
1412-PP2127-49
1412-PP2127-50
1412-PP2127-51
5
6
Cat. No.
1412-PP2137-01
1412-PP2137-02
1412-PP2137-03
1412-PP2137-04
1412-PP2137-05
1412-PP2137-06
8
9
10
11
12
13
www.ab.com/catalogs
Publication A117-CA001A-EN-P
8-77
Power Monitoring
Product Selection
Current Transformers Split Core (Bulletin 1411) for Energy Management Systems and Instrumentation
ANSI Metering
Class
Current Burden
B0.1
Ratio
[VA]
B0.2
B0.5
Accuracy
Cat. No.
ANSI Metering
Class
Current Burden
B0.1 B0.2 B0.5
Ratio
[VA]
250:5
300:5
400:5
2.0
1.5
4.8
2.4
2.4
1411-600-251
4.8
1411-600-301
1411-600-401
500:5
2.0
2.4
4.8
1411-600-501
600:5
2.5
2.4
2.4
2.4
1411-600-601
1411-600-801
1411-600-102
1411-600-122
800:5
1000:5
1200:5
1.5
5.0
7.5
15
1.2
1.2
0.6
1.2
1.2
1.2
2.4
1.2
1500:5
20
0.6
0.6
1.2
1411-600-152
1600:5
20
0.6
0.6
1.2
1411-600-162
1411-600-202
2000:5
30
0.6
0.6
0.6
500:5
6.0
1%
1411-608-501
600:5
8.0
1%
1411-608-601
800:5
12
1%
1411-608-801
1000:5
13
1%
1411-608-102
1200:5
16
1%
1411-608-122
1500:5
25
1%
1411-608-152
1600:5
27
1%
1411-608-162
2000:5
33
1%
1411-608-202
2500:5
42
1%
1411-608-252
3000:5
50
1%
1411-608-302
3200:5
54
1%
1411-608-322
400:5
1.0
4.8
500:5
1.5
4.8
4.8
600:5
2.0
2.4
4.8
800:5
2.5
1.2
2.4
1000:5
5.0
1.2
1.2
1411-601-401
100:0.1
1%
1411-614-101-01
1411-601-501
200:0.1
1%
1411-614-201-01
4.8
1411-601-601
1411-601-801
100:5
1.0
5%
1411-615-101
1411-601-102
200:5
2.0
3%
1411-615-201
3.5
1%
1411-615-301
4.8
1200:5
10.0
1.2
1.2
2.4
1411-601-122
1500:5
15.0
1.2
1.2
1.2
1411-601-152
400:5
8.5
1%
1411-615-401
1600:5
15.0
1.2
1.2
1.2
1411-601-162
200:1
1.5
1%
1411-615-201-1
2000:5
20.0
0.6
0.6
1.2
1411-601-202
200:5
2.0
100:5
1.0
150:5
1.0
3%
1411-616-201
1411-604-101
400:5
5.0
1%
1411-616-401
4%
1411-604-151
800:5
5.0
1%
1411-616-801
400:0.1
1%
1411-616-401-01
1.0
2.4
200:5
1.0
2%
1411-604-201
250:5
2.0
2%
1411-604-251
300:5
2.0
1.5%
1411-604-301
400:5
4.8
1411-617-401
400:5
2.5
1.5%
1411-604-401
500:5
2.0
2.4
4.8
1411-617-501
600:5
2.5
2.4
2.4
1411-617-601
1411-606-201
800:5
5.0
1.2
1.2
2.4
1411-617-801
7.5
1.2
1.2
2.4
1411-617-102
15.0
0.6
1.2
1.2
1411-617-122
200:5
5%
300:5
Cat. No.
Accuracy
2.5
2%
250:5
3.0
1%
1411-606-251
1000:5
300:5
3.5
1%
1411-606-301
1200:5
350:5
4.0
1%
1411-606-351
400:5
5.0
1%
1411-606-401
500:5
6.0
1%
1411-606-501
600:5
8.0
1%
1411-606-601
750:5
10
1%
1411-606-751
800:5
12
1%
1411-606-801
1000:5
15
1%
1411-606-102
1200:5
20
1%
1411-606-122
10
11
12
13
www.ab.com/catalogs
8-78
Publication A117-CA001A-EN-P
Power Monitoring
Product Selection
Current Transformers Solid Core (Bulletin 1411)
ANSI Metering Class
Current Burden
Ratio
[VA] B0.1 B0.2 B0.5 B0.9 B1.8
Cat. No.
Cat. No.
2.50 in. dia. with square exterior (for relay and metering)
600:5
0.3
0.3
0.3
0.6
0.6
1411-120-601
50:5
1.5
2.4
800:5
0.3
0.3
0.3
0.3
0.6
1411-120-801
75:5
2.5
1.2
2.4
1411-180SHT-500
1411-180SHT-750
2.4
4.8
1000:5
0.3
0.3
0.3
0.3
0.6
1411-120-102
100:5
2.5
1.2
1411-180SHT-101
0.6
1.2
2.4
4.8
1200:5
0.3
0.3
0.3
0.3
0.3
1411-120-122
150:5
5.0
1500:5
0.3
0.3
0.3
0.3
0.3
1411-120-152
200:5
12.5
1411-180SHT-151
0.6
0.6
1.2
2.4
1600:5
0.3
0.3
0.3
0.3
0.3
1411-120-162
250:5
1411-180SHT-201
12.5
0.3
0.3
0.6
1.2
1411-180SHT-251
300:5
25
0.3
0.3
0.6
1.2
2.4
2000:5
0.3
0.3
0.3
0.3
0.3
1411-120-202
2500:5
0.3
0.3
0.3
0.3
0.3
1411-120-252
400:5
50
0.3
0.3
0.3
0.6
1.2
1411-180SHT-401
3000:5
0.3
0.3
0.3
0.3
4000:5
0.3
0.3
0.3
0.3
0.3
1411-120-302
500:5
50
0.3
0.3
0.3
0.6
1.2
1411-180SHT-501
0.3
1411-120-402
600:5
50
0.3
0.3
0.3
0.6
1.2
1411-180SHT-601
750:5
50
0.3
0.3
0.3
0.6
1.2
1411-180SHT-751
1411-180SHT-301
1000:5
0.3
0.3
0.3
0.6
1.2
1411-125-102
800:5
75
0.3
0.3
0.3
0.6
1.2
1411-180SHT-801
1200:5
0.3
0.3
0.3
0.6
1.2
1411-125-122
1000:5
100
0.3
0.3
0.3
0.3
0.6
1411-180SHT-102
1500:5
0.3
0.3
0.3
0.3
0.6
1411-125-152
1200:5
125
0.3
0.3
0.3
0.3
0.3
1411-180SHT-122
1600:5
0.3
0.3
0.3
0.3
0.6
1411-125-162
1500:5
160
0.3
0.3
0.3
0.3
0.3
1411-180SHT-152
2000:5
0.3
0.3
0.3
0.3
0.6
1411-125-202
1600:5
175
0.3
0.3
0.3
0.3
0.3
1411-180SHT-162
2500:5
0.3
0.3
0.3
0.3
0.6
1411-125-252
2000:5
200
0.3
0.3
0.3
0.3
0.3
1411-180SHT-202
3000:5
0.3
0.3
0.3
0.3
0.6
1411-125-302
3500:5
0.3
0.3
0.3
0.3
0.3
1411-125-352
4000:5
0.3
0.3
0.3
0.3
0.3
1411-125-402
4.0
0.6
1.2
2.4
2.4
4.8
1411-126-401
500:5
7.5
0.6
0.6
1.2
2.4
2.4
1411-126-501
600:5
10
0.6
0.6
1.2
2.4
2.4
1411-126-601
800:5
20
0.3
0.3
0.6
0.6
1.2
1411-126-801
1000:5
25
0.3
0.3
0.6
0.6
1.2
1411-126-102
1200:5
40
0.3
0.3
0.3
0.6
0.6
1411-126-122
1500:5
50
0.3
0.3
0.3
0.3
0.6
1411-126-152
1600:5
50
0.3
0.3
0.3
0.3
0.6
1411-126-162
2000:5
60
0.3
0.3
0.3
0.3
0.3
1411-126-202
2500:5
75
0.3
0.3
0.3
0.3
0.3
1411-126-252
3000:5
90
0.3
0.3
0.3
0.3
0.3
1411-126-302
3200:5
95
0.3
0.3
0.3
0.3
0.3
1411-126-322
3500:5
100
0.3
0.3
0.3
0.3
0.3
1411-126-352
4000:5
125
0.3
0.3
0.3
0.3
0.3
1411-126-402
5000:5
140
0.3
0.3
0.3
0.3
0.3
1411-126-502
6000:5
140
0.3
0.3
0.3
0.3
0.3
1411-126-602
2.50 in. dia. with round exterior (for relay and metering)
50:5
1.5
2.4
75:5
2.5
1.2
2.4
1411-180RL-500
1411-180RL-750
2.4
4.8
100:5
2.5
1.2
1411-180RL-101
0.6
1.2
2.4
4.8
150:5
5.0
1411-180RL-151
200:5
12.5
0.6
0.6
1.2
2.4
1411-180RL-201
250:5
12.5
0.3
0.3
0.6
1.2
1411-180RL-251
300:5
25
0.3
0.3
0.6
1.2
2.4
400:5
50
0.3
0.3
0.3
0.6
1.2
1411-180RL-401
500:5
50
0.3
0.3
0.3
0.6
1.2
1411-180RL-501
600:5
50
0.3
0.3
0.3
0.6
1.2
1411-180RL-601
750:5
50
0.3
0.3
0.3
0.6
1.2
1411-180RL-751
800:5
75
0.3
0.3
0.3
0.6
1.2
1411-180RL-801
1000:5
100
0.3
0.3
0.3
0.3
0.6
1411-180RL-102
1200:5
125
0.3
0.3
0.3
0.3
0.3
1411-180RL-122
1500:5
160
0.3
0.3
0.3
0.3
0.3
1411-180RL-152
1600:5
175
0.3
0.3
0.3
0.3
0.3
1411-180RL-162
2000:5
200
0.3
0.3
0.3
0.3
0.3
1411-180RL-202
1411-180RL-301
www.ab.com/catalogs
Current Burden
Ratio
[VA]
Accuracy
Cat. No.
1.5
2%
1411-2DRL-500
60:5
2.0
2%
1411-2DRL-600
75:5
3.0
2%
1411-2DRL-750
80:5
4.0
2%
1411-2DRL-800
100:5
5.0
1%
1411-2DRL-101
120:5
5.0
1%
1411-2DRL-121
125:5
5.0
1%
1411-2DRL-1250
150:5
8.0
1%
1411-2DRL-151
200:5
10.0
1%
1411-2DRL-201
250:5
12.5
1%
1411-2DRL-251
300:5
15
1%
1411-2DRL-301
1.5
3%
1411-2SFT-500
60:5
2.0
3%
1411-2SFT-600
75:5
2.0
2%
1411-2SFT-750
80:5
2.0
2%
1411-2SFT-800
100:5
2.0
1%
1411-2SFT-101
120:5
2.5
1%
1411-2SFT-121
125:5
2.5
1%
1411-2SFT-1250
150:5
4.0
1%
1411-2SFT-151
200:5
4.0
1%
1411-2SFT-201
250:5
6.0
1%
1411-2SFT-251
8.0
1%
1411-2SFT-301
300:5
3
4
6
7
1.13 in. dia. with square exterior and bracket (for relay and metering)
50:5
1.00 in. dia. with round exterior (for relay and metering)
50:5
8
9
10
1.13 in. dia. with square exterior (for relay and metering)
50:5
1.5
3%
1411-2SHT-500
60:5
2.0
3%
1411-2SHT-600
75:5
2.0
2%
1411-2SHT-750
80:5
2.0
2%
1411-2SHT-800
100:5
2.0
1%
1411-2SHT-101
120:5
2.5
1%
1411-2SHT-121
125:5
2.5
1%
1411-2SHT-1250
150:5
4.0
1%
1411-2SHT-151
200:5
4.0
1%
1411-2SHT-201
250:5
6.0
1%
1411-2SHT-251
300:5
8.0
1%
1411-2SHT-301
11
12
13
Publication A117-CA001A-EN-P
8-79
Power Monitoring
Product Selection
Current Transformers Solid Core (Bulletin 1411)
Cat. No.
1.47 in. dia. window size (for energy mgmt. systems and instrumentation)
200:5
12.5
0.6
0.6
1.2
2.4
4.8
1411-605-201
400:5
25
0.3
0.3
0.6
1.2
1.2
1411-605-401
600:5
30
0.3
0.3
0.3
0.6
1.2
1411-605-601
2.31 in. dia. window size (for energy mgmt. systems and instrumentation)
150:5
2.5
0.6
1.2
4.8
4.8
800:5
35
0.3
0.3
0.3
0.6
250:5
4
5
6
7
8
9
10
1411-607-801
3.25 in. dia. window size with round exterior (for metering)
200:5
0.6
1411-607-151
5.0
7.5
1.2
0.6
1.2
0.6
2.4
1.2
4.8
2.4
4.8
4.8
1411-8RL-201
1411-8RL-251
300:5
15
0.6
0.6
1.2
2.4
2.4
1411-8RL-301
400:5
25
0.3
0.3
0.6
1.2
2.4
1411-8RL-401
500:5
35
0.3
0.3
0.6
0.6
1.2
1411-8RL-501
600:5
50
0.3
0.3
0.6
0.6
1.2
1411-8RL-601
750:5
50
0.3
0.3
0.6
0.6
1.2
1411-8RL-751
800:5
60
0.3
0.3
0.3
0.6
0.6
1411-8RL-801
1000:5
75
0.3
0.3
0.3
0.6
0.6
1411-8RL-102
1200:5
75
0.3
0.3
0.3
0.3
0.6
1411-8RL-122
1500:5
90
0.3
0.3
0.3
0.3
0.6
1411-8RL-152
1600:5
100
0.3
0.3
0.3
0.3
0.6
1411-8RL-162
2000:5
120
0.3
0.3
0.3
0.3
1411-8RL-202
2500:5
50
0.3
0.3
0.3
0.3
1411-8RL-252
3000:5
60
0.3
0.3
0.3
0.3
1411-8RL-302
3200:5
70
0.3
0.3
0.3
0.3
1411-8RL-322
4000:5
80
0.3
0.3
0.3
0.3
1411-8RL-402
12
13
9307-EM64MGRENE
9307-EM10KMGRENE
9307-EMRTENE
9307-EM83PXENE
9307-EM643PXENE
9307-EM10K3PXENE
RSEnergyMetrix ReportsPlus
9307-EMRPTENE
RSEnergyMetrix ChartsPlus
9307-EMCHTENE
9307-8MGDBPENE
9307-64MGDBPENE
9307-10KMGDBPENE
9307-8MGDBCENE
9307-64MGDBCENE
9307-10KMGDBCENE
3.25 in. dia. window size with square exterior (for metering)
Cat. No.
9307-RSP32WENE
200:5
5.0
1.2
1.2
2.4
4.8
4.8
1411-8SHT-201
250:5
7.5
0.6
0.6
1.2
2.4
4.8
1411-8SHT-251
9307-RSP32LXRENE
300:5
15
0.6
0.6
1.2
2.4
2.4
1411-8SHT-301
9307-RSP32LXWENE
400:5
25
0.3
0.3
0.6
1.2
2.4
1411-8SHT-401
9307-RSPPLXRENE
500:5
35
0.3
0.3
0.6
0.6
1.2
1411-8SHT-501
600:5
50
0.3
0.3
0.6
0.6
1.2
1411-8SHT-601
9307-RSPPLXWENE
50
0.3
0.3
0.6
0.6
1.2
750:5
1411-8SHT-751
800:5
60
0.3
0.3
0.3
0.6
0.6
1411-8SHT-801
1000:5
75
0.3
0.3
0.3
0.6
0.6
1411-8SHT-102
1200:5
75
0.3
0.3
0.3
0.3
0.6
1411-8SHT-122
1500:5
90
0.3
0.3
0.3
0.3
0.6
1411-8SHT-152
1600:5
100
0.3
0.3
0.3
0.3
0.6
1411-8SHT-162
2000:5
120
0.3
0.3
0.3
0.3
1411-8SHT-202
2500:5
50
0.3
0.3
0.3
0.3
1411-8SHT-252
3000:5
60
0.3
0.3
0.3
0.3
1411-8SHT-302
3200:5
70
0.3
0.3
0.3
0.3
1411-8SHT-322
4000:5
80
0.3
0.3
0.3
0.3
1411-8SHT-402
1.05 in. dia. window size (for ammeters, energy mgmt. sys., and instr.)
11
Cat. No.
9307-EM8MGRENE
50:5
1.5
3%
1411-AL-500
60:5
2.0
3%
1411-AL-600
75:5
2.0
2%
1411-AL-750
80:5
2.0
2%
1411-AL-800
100:5
2.0
1%
1411-AL-101
120:5
2.5
1%
1411-AL-121
125:5
2.5
1%
1411-AL-1250
150:5
4.0
1%
1411-AL-151
200:5
4.0
1%
1411-AL-201
250:5
6.0
1%
1411-AL-251
300:5
8.0
1%
1411-AL-301
400:5
10
1%
1411-AL-401
www.ab.com/catalogs
8-80
9307-RSP32RENE
9307-RSPPRENE
9307-RSPPWENE
Cat. No.
1407-CGCM
Publication A117-CA001A-EN-P
Cat. No.
1413-CAP-ME
1413-CAP-ME-PE
Bulletin 4983
Bulletin
Type
4983-DS
4983-DD
Features
4983-DH
DIN Rail Heavy-Duty AC Surge
Protective Device
2
3
AC Network
Max. Continuous Operating Voltage
Protection Level (Up)
UL1449 Voltage Protection Rating
(VPR)
Standards Compliance/Certifications
Operating Temperature (noncondensing)
Product Selection
110277/480Y
110600V
420 mA loop
RS232, RS485
150V AC
330V AC
150690V AC
828V DC
1 or 1.5 kV
0.91.8 kV
2540V
0.4 or 0.6 kV
-40...+80 C
-40...+80 C
-40...+80 C
Page 8-82
Page 8-84
Page 8-87
4
5
6
7
Bulletin
Type
Features
Operating Voltage
Max. Continuous Operating Voltage
4983-PF
4983-DC
120V or 240V AC
230 A
320 A
Ampacity
Line Frequency
Standards Compliance/Certifications
Operating Temperature (non-condensing)
Product Selection
4763 Hz
4763 Hz
UL 1283, CSA, CE
Page 8-89
Page 8-93
9
10
11
12
13
www.ab.com/catalogs
Publication A117-CA001A-EN-P
8-81
Bulletin 4983-DH
0
1
2
Table of Contents
Standards Compliance
Certifications
Examples given in this section are for reference purposes. This basic explanation should not be used for product selection; not all
combinations will produce a valid catalog number.
4983 D
5
a
Mount
120 25
d
c
Voltage
Current Rating
Type
Code
Description
Code
Description
Code
Description
Code
Description
120
120V
25
25 kA
DIN Rail
Heavy Duty
300
50
50 kA
Product Selection
7
8
AC Network
120
120/208
9
230/400
10
277/480Y
11
12
13
230/400
277/480 Y
Max.
Continuous
Operating
No. of Poles
Voltage
Connection and Devices (MCOV) (Uc)
Mode
Needed
[V AC]
L/G or N/G
L/G, N/G
L1/G, L2/G,
L3/G, N/G
L/G or N/G
L/G, N/G
L1/G, L2/G,
L3/G, N/G
L1/G, L2/G,
L3/G, N/G
L1/G, L2/G,
L3/G, N/G
L/G or N/G
L/G, N/G
L1/G, L2/G,
L3/G or N/G
L1/G, L2/G,
L3/G, N/G
L1/G, L2/G,
L3/G, N/G
Protection
Level (Up)
[kV]
UL 1449
Voltage
Protection
Rating
(VPR)
[V]
Appropriate
Fusing1
[A Max.]
Cat. No.
20
1.0
1200
250
4983-DH120-25
70
20
1.5
900
250
4983-DH300-25
70
20
1.5
1200
500
4983-DH300-50
Lightning
Current
10/350 s
(Iimp) [kA]
Max.
Discharge
Current
8/20s (Imax)
[kA]
Nominal
Discharge
Current
8/20s (In)
[kA]
150
25
70
330
25
330
50
1 Fuses required to protect the surge protector in case of short-circuit failure. They must be installed in series with each pole of the surge protector.
Note: N = Neutral
L/N = Line/neutral
N/G = Neutral/ground
www.ab.com/catalogs
8-82
Publication A117-CA001A-EN-P
Bulletin 4983-DH
Standards Compliance
Certifications
Conductor Material
Conductor Range
Strip Length
Tightening Torque
No. of Conductors/Terminal
Operating Temperature
-40+80 C
Approximate Dimensions
Note: Dimensions are shown in millimeters. Dimensions are not intended for manufacturing purposes.
22.5
4
5
45
6
7
22.5
8
9
35.6
6.6
10
43.8
59.8
11
61.4
12
13
www.ab.com/catalogs
Publication A117-CA001A-EN-P
8-83
Bulletin 4983-DS
Table of Contents
Standards Compliance
UL 1449, 3rd Edition
CSA C22.2, No. 8
IEC 61643-1
EN 61643-11
Certifications
cURus Recognized
Component (File No.
E334011, Guide VZCA2,
VZCA8)
CE Marked
CSA
3
4
5
4983 D
120 40
c
1
e
6
7
Mount
Type
Voltage
Current Rating
Poles
Code
Description
Code
Description
Code
Description
Code
Description
Code
Description
DIN Rail
Standard duty
120
120V
40
40 kA
1-pole
230
230V
80
80 kA
2-pole
277
480Y/277V
3-pole
480
480V Delta
4-pole
600
600V
1G
1-pole + 1
3G
3-pole + 1
8
9
10
11
12
13
www.ab.com/catalogs
8-84
Publication A117-CA001A-EN-P
Bulletin 4983-DS
AC
Connection
Network
Mode
120
120/
208Y
230/
400
277
277/
480Y
480D
230/
400
120
120/
208Y
230/
400
277
277/
480Y
480D
600D
No. of
Poles
Max.
Continuous
Max.
Nominal
UL 1449
Operating Discharge Discharge
Voltage
Voltage
Current
Current Protection Protection Appropriate
(MCOV)
Level
8/20s
Cat. No.
8/20s (In)
Rating
Fuse1
(Uc) [V AC] (Imax) [kA]
(Up) [kV] (VPR) [V]
[kA]
Base and Module
[A] Max.
L/G or
N/G
4983-DS120-401
L/G, N/G
4983-DS120-402
L1/G,
L2/G,
L3/G
L1/G,
L2/G,
L3/G, N/G
4983-DS120-404
L/G or
N/G
4983-DS230-401
L/G, N/G
L1/G,
L2/G,
N/G
4983-DS230-403
L/G or
N/G
4983-DS277-401
L1/G,
L2/G,
L3/G
L1/G,
L2/G,
L3/G, N/G
L1/G,
L2/G,
L3/G
L/G, N/G
L1/G,
L2/G,
L3/G, N/G
L/G or
N/G
L/G, N/G
L1/G,
L2/G,
L3/G
4983-DS120-803
L/G or
N/G
4983-DS230-801
L/G, N/G
L1/G,
L2/G, N/G
4983-DS230-803
L/G or
N/G
4983-DS277-801
L1/G,
L2/G,
L3/G
0.9
275
1.25
40
700
4983-DS230-402
1000
20
420
4983-DS120-403
4983-DS120-40
L1/G,
L2/G,
L3/G
2
3
4983-DS230-40
125
1.8
4983-DS277-403
1500
4
4983-DS277-40
4983-DS277-404
550
275
1.8
40
20
1.25
1800
4983-DS480-403
1000
4983-DS230-401G
1000
125
4983-DS230-403G
4983-DS480-40
6
4983-DS230-40 4983-DS230-40G
4983-DS120-801
150
0.9
275
1.25
80
4983-DS120-802
700
1000
20
4983-DS230-802
125
420
1500
4983-DS120-80
8
4983-DS230-80
4983-DS277-803
10
4983-DS277-804
1.8
680
4983-DS277-804
11
2500
4
0
1
4983-DS277-80
L1/G,
L2/G,
L3/G, N/G
L1/G,
L2/G,
L3/G
150
Cat. No.
Replacement
Module Only
Cat. No.
Replacement
Module Only
Gas Discharge
Tube
690
4983-DS600-804
4983-DS600-80
1 Fuses required to protect the surge protector in case of short-circuit failure. They must be installed in series with each pole of the surge protector.
12
Note: N = Neutral
L/N = Line/neutral
N/G = Neutral/ground
13
www.ab.com/catalogs
Publication A117-CA001A-EN-P
8-85
Bulletin 4983-DS
Connection/Mounting Type
Standards Compliance
Certifications
Conductor Material
Conductor Range
Strip Length
Tightening Torque
No. of Conductors/Terminal
Operating Temperature
-40+80 C
3
Approximate Dimensions
Note: Dimensions are shown in millimeters. Dimensions are not intended for manufacturing purposes.
4
5
6
7
8
9
10
11
12
13
www.ab.com/catalogs
8-86
Publication A117-CA001A-EN-P
Bulletin 4983-DD
Table of Contents
Product Selection ...... this page
Specifications.............. 8-88
Approximate
Dimensions................... 8-88
0
1
Standards Compliance
UL 497B
IEC 61643-21
Certifications
UL Listed (File No. E317213,
Guide QVGQ)
CE Marked
4983 D
06
4
5
Mount
Type
Voltage
Code
Description
Code
Description
Code
DIN Rail
Dataline UL 497B
06
Description
6V
12
12V
24
24V
Product Selection
Max. Continuous
Operating Voltage
(MCOV) [V DC]
Nominal Discharge
Current 8/20s (In)
[kA]
Max. Discharge
Current 8/20s
(Imax) [kA]
Protection Level
(Up)
Line Type
Cat. No.
420 mA Loop
type
28
20
40 V
24V
4983-DD24
RS232 type
15
20
30 V
12V
4983-DD12
High-speed
transmission (LAN)
RS485 type, RS422
type
20
25 V
6V
4983-DD06
AC Network
8
9
10
11
12
13
www.ab.com/catalogs
Publication A117-CA001A-EN-P
8-87
Bulletin 4983-DD
Connection/Mounting Type
Standards Compliance
Certifications
CE Marked, UL Listed
Conductor Material
Conductor Range
Strip Length
Tightening Torque
No. of Conductors/Terminal
Operating Temperature
-40+80 C
2
3
Approximate Dimensions
Note: Dimensions are shown in millimeters. Dimensions are not intended for manufacturing purposes.
4
48.3
13.2
42.7
6
7
45
89
8
9
10
11
64.7
12
13
www.ab.com/catalogs
8-88
Publication A117-CA001A-EN-P
Bulletin 4983-PF
Table of Contents
Standards Compliance
0
1
UL 1283
IEC 61643-1
EN 61643-11
2
Certifications
UR recognized component
(File No. E316867, Guide
FOKY2)
CE Marked
CSA C22.2
3
4
4983 P
120 2
c
Mount
Type
Voltage
Current Rating
Code
Description
Code
Description
Code
Description
Code
Description
Panel/Flange
Filter UL 1283
120
120V
2.5 A
240
240V
5A
15
15 A
30
30 A
6
7
Product Selection
Operating Voltage
[V AC]
120
240
Ampacity [A]
Cat. No.
2.5
4983-PF120-02
5.0
4983-PF120-05
15
4983-PF120-15
30
4983-PF120-30
2.5
4983-PF240-02
5.0
4983-PF240-05
15
4983-PF240-15
30
4983-PF240-30
8
9
10
11
12
13
www.ab.com/catalogs
Publication A117-CA001A-EN-P
8-89
Bulletin 4983-PF
Connection/Mounting Type
Enclosure
Approximate Weight
2.5 A 1.5 lb
5.0 A 1.5 lb
15 A 4 lb
30 A 6.5 lb
Modes of Protection
Line Neutral
Line Line
Line PE
Neutral PE
1
2
Certifications
Status Indication
Response Time
Operating Temperature
Fusing
4
5
15 kA
15 kA
15 kA
Approximate Dimensions
Note: Dimensions are shown in inches (millimeters). Dimensions are not intended for manufacturing purposes.
GREEN LED
FOR STATUS INDICATION
7
8
4.812
[122.24]
.177 [4.49]
4 HOLES
L/L1
N/L2
G
L/L1
N/L2
G
2.875
[73.02]
2.125
[53.98]
6-32 SCREW
6 PLACES
4.375
[111.12]
5.312
[134.92]
10
LOAD
LINE
11
1.812
[46.04]
12
13
www.ab.com/catalogs
8-90
Publication A117-CA001A-EN-P
Bulletin 4983-PF
GREEN LED
FOR STATUS INDICATION
7.625
[193.68]
.188 [4.77]
4 HOLES
8-32 SCREW
6 PLACES
3.500
[88.90]
L/L1
L/L1
N/L2
N/L2
4.500
[114.30]
3
8.375
[212.73]
9.125
[231.78]
5
6
LOAD
LINE
2.500
[63.50]
7
Cat. Nos. 4983-PF120-30, -PF240-15, -PF240-30
8
9
10
11
12
13
www.ab.com/catalogs
Publication A117-CA001A-EN-P
8-91
Bulletin 4983-PF
.188 [4.77]
4 HOLES
8-32 SCREW
6 PLACES
3.500
[88.90]
L/L1
N/L2
G
L/L1
N/L2
G
4.600
[116.84]
2
6.750
[171.45]
7.276
[184.81]
4
7.787
[197.79]
2.500
[63.50]
LOAD
LINE
GREEN LED
FOR STATUS INDICATION
7
.188
4 HOLES
6-32 SCREW
6 PLACES
8
L/L1
N/L2
G
L/L1
N/L2
G
4.600
REF
3.500 REF
9
5.250 REF
10
5.775 REF
11
6.225 MAX
12
LOAD
LINE
2.500 MAX
13
Cat. No. 4983-PF240-05
www.ab.com/catalogs
8-92
Publication A117-CA001A-EN-P
Bulletin 4983-DC
Table of Contents
Standards Compliance
UL 1283
UL 1449
IEC 61643-1
EN 61643-11
CSA C22.2
0
1
2
Certifications
cURus Recognized
Component (File No.
E334011, Guide VZCA2,
VZCA8), (File No. E316867,
Guide FOKY2)
CSA
CE Marked
120
4
5
Examples given in this section are for reference purposes. This basic explanation should not be used for product selection; not all
combinations will produce a valid catalog number.
4983 D
Mount
Type
Voltage
Current Rating
Code
Description
Code
Description
Code
Description
Code
Description
DIN Rail
120
120V
3A
240
240V
5A
10
10 A
20
20 A
7
8
Connection
Mode
AC Network
Frequency
[Hz]
120V AC
Maximum
Discharge Current
8/20s (Imax) [kA]
L/G
L/N
N/G
Nominal
Discharge
Current
8/20s (In)
[kA]
47...63
L/G
600
10
25
10
150
L/G, L/N, N/G
240V AC
Max.
Continuous
Operating
Voltage
(MCOV) (Uc)
[V AC]
L/N
400
N/G
600
L-L
320
1200
800
Ampacity [A]
Cat. No.
3.0
4983-DC120-03
5.0
4983-DC120-05
10
4983-DC120-10
20
4983-DC120-20
3.0
4983-DC240-03
5.0
4983-DC240-05
10
4983-DC240-10
20
4983-DC240-20
10
11
12
13
www.ab.com/catalogs
Publication A117-CA001A-EN-P
8-93
Bulletin 4983-DC
Connection/Mounting Type
Enclosure
Approximate Weight
3 A 1 lb
5 A 1 lb
10 A 1.5 lbs
20 A 1.5 lbs
Modes of Protection
Line Neutral
Line Line
Line PE
Neutral PE
1
2
3
Certifications
Status Indication
Response Time
Operating Temperature
Fusing
Approximate Dimensions
Note: Dimensions are shown in inches (millimeters). Dimensions are not intended for manufacturing purposes.
6
7
1.92
(48.77)
3.72
(94.49)
3.08
(78.23)
2.85
(72.4)
LINE
0.18
(4.57)
0.17
(4.32)
+ + +
0.16
(4.06)
LN
LINE
35mm
DIN RAIL
MOUNTING
4.84
(122.94)
9
STATUS
LOAD
NC COM NO L N
10
+ + + + + +
LOAD
WIRE RANGE
24-12 AWG
(9X)
11
12
13
www.ab.com/catalogs
8-94
Publication A117-CA001A-EN-P
Bulletin 4983-DC
0
1
2
3
2.56
(65.02)
3.72
(94.49)
4
L N
LINE
35 mm
DIN RAIL
MOUNTING
STATUS
4.84
(122.94)
NC COM NO
6
7
LOAD
L N
8
WIRE RANGE
26-10 AWG
(9X)
9
10
11
12
13
www.ab.com/catalogs
Publication A117-CA001A-EN-P
8-95