UNBALANCED COUPLES AND FORCES FOR

GEMINI A352 & A354 @ 1800 RPM


Pressure
Rating
PSI
2500

1725

1850

1750

1140

840

635

525

275

200

1140 x 1300

90 Series
Cyl. Bore
[in]
DA Cyl.
2.50
2.75
3.00
3.25
3.50
3.75
4.00
4.25
4.50
4.75
5.00
5.25
5.50
5.75
6.00
6.25
6.50
6.75
7.00
7.25
7.50
7.75
8.00
8.25
8.50
9.00
9.50
10.00
10.50
11.00
11.50
12.00
12.50
13.00
13.50
14.00
14.50
15.00
15.50
Stepped Cyl.
6.00 x 2.75
6.50 x 3.25

Horizontal Couples
Primary Secondary
[Kip*ft]
[Kip*ft]
1.03
1.09
1.19
1.28
1.37
1.48
1.59
1.70
1.84
1.95
2.10
2.25
2.40
1.88
2.08
2.11
2.29
2.25
2.43
2.45
2.67
2.53
2.80
2.71
2.94
3.02
3.09
2.90
3.28
2.66
3.40
2.92
3.52
3.09
3.53
3.39
4.36
3.63
4.48

0.38
0.39
0.41
0.43
0.45
0.47
0.49
0.51
0.54
0.56
0.59
0.62
0.65
0.55
0.59
0.60
0.63
0.62
0.66
0.66
0.71
0.68
0.73
0.72
0.76
0.78
0.79
0.75
0.83
0.71
0.85
0.76
0.88
0.79
0.88
0.85
1.05
0.90
1.07

1.99
2.23

0.57
0.62

Vertical Couples [Kip*ft]


Primary
0.98
Secondary
0.00
Rated Speed
RPM
1800

For A354 - 4 Throw Compressor:


Treat as two 2 throw compressors. Unit A consists of cranks
1 & 2 with equal weights and unit B consists of cranks 3 & 4
with equal weights.
1. Primary Vertical Couple equals 1.414 times the chart value
for unit A or unit B (PV is not dependent on cylinder size).
2. Secondary Vertical Couple equals 0 as in 2 throw case.
3. Primary Horizontal Couple equals 0.707 times the 2 throw
chart value (A352 chart to left) for unit A plus 0.707 times the
chart value (A352 chart to left) for unit B.
4. Secondary Horizontal Couple equals the 2 throw chart value
(A352 chart to left) for unit A minus the 2 throw chart value
(A352 chart to left) for unit B.
Example: A354, 1800 RPM
Cranks 1 & 2 = 9.00 & 5.00 Cylinder (choose 9.00 cylinder, 5.00 is balanced)
Cranks 3 & 4 = 9.00 & 5.00 Cylinder (choose 9.00 cylinder, 5.00 is balanced)
Primary Vertical Couple = 1.414 x 0.98 = 1.38 Kip*ft
Secondary Vertical Couple = 0 Kip*ft
Primary Horizontal Couple = (0.707 x 3.02) + (0.707 x 3.02) = 4.27 Kip*ft
Secondary Horizontal Couple = 0.78 - 0.78 = 0 Kip*ft

Notes:
1. Horizontal primary and secondary forces are zero.
2. Vertical primary and secondary forces are zero.
3. Select cylinder bore with largest unbalance couple. Opposing bore is balanced.
4. For lower speeds, multiply unbalance couple by the square of
the ratio of the desired speed to the rated speed.
5. For any questions contact the GE Gemini Engineering Department @ 1-800-297-4320.

UNBALANCED COUPLES AND FORCES FOR


GEMINI D422 & D424 @ 1600 RPM
Pressure
Rating
PSI
1850

1750

1140

840

635

525

275

200

90 Series
Cyl. Bore
[in]
DA Cyl.
4.00
4.25
4.50
4.75
5.00
5.25
5.50
5.75
6.00
6.25
6.50
6.75
7.00
7.25
7.50
7.75
8.00
8.25
8.50
9.00
9.50
10.00
10.50
11.00
11.50
12.00
12.50
13.00
13.50
14.00
14.50
15.00
15.50

Horizontal Couples
Primary Secondary
[Kip*ft]
[Kip*ft]
12.97
13.29
13.40
13.63
13.77
13.93
14.11
14.65
14.91
15.15
15.42
14.74
14.90
15.00
15.06
15.98
16.10
16.22
16.33
14.74
15.23
14.91
15.56
15.18
15.82
15.43
16.14
15.81
15.94
16.63
17.11
16.93
16.63

1.28
1.33
1.34
1.37
1.40
1.42
1.45
1.53
1.56
1.60
1.64
1.54
1.56
1.58
1.58
1.72
1.74
1.76
1.77
1.54
1.61
1.56
1.66
1.60
1.70
1.64
1.74
1.70
1.71
1.81
1.88
1.86
1.81

Vertical Couples [Kip*ft]


Primary
4.25
Secondary
0.00
Rated Speed
RPM
1600

For D424 - 4 Throw Compressor:


Treat as two 2 throw compressors. Unit A consists of cranks
1 & 2 with equal weights and unit B consists of cranks 3 & 4
with equal weights.
1. Primary Vertical Couple equals 1.414 times the chart value
for unit A or unit B (PV is not dependent on cylinder size).
2. Secondary Vertical Couple equals 0 as in 2 throw case.
3. Primary Horizontal Couple equals 0.707 times the 2 throw
chart value (D422 chart to left) for unit A plus 0.707 times the
chart value (D422 chart to left) for unit B.
4. Secondary Horizontal Couple equals the 2 throw chart value
(D422 chart to left) for unit A minus the 2 throw chart value
(D422 chart to left) for unit B.
Example: D424, 1600 RPM
Cranks 1 & 2 = 9.00 & 5.00 Cylinder (choose 9.00 cylinder, 5.00 is balanced)
Cranks 3 & 4 = 9.00 & 5.00 Cylinder (choose 9.00 cylinder, 5.00 is balanced)
Primary Vertical Couple = 1.414 x 4.25 = 6.01 Kip*ft
Secondary Vertical Couple = 0 Kip*ft
Primary Horizontal Couple = (0.707 x 14.74) + (0.707 x 14.74) = 20.84 Kip*ft
Secondary Horizontal Couple = 1.54 - 1.54 = 0 Kip*ft

Notes:
1. Horizontal primary and secondary forces are zero.
2. Vertical primary and secondary forces are zero.
3. Select cylinder bore with largest unbalance couple. Opposing bore is balanced.
4. For lower speeds, multiply unbalance couple by the square of
the ratio of the desired speed to the rated speed.
5. For any questions contact the GE Gemini Engineering Department @ 1-800-297-4320.

UNBALANCED COUPLES AND FORCES FOR


GEMINI D502 & D504 @ 1200 RPM
Pressure
Rating
PSI
3600

2500

2200

1800
1500

1250

800

635

635

250

250

250

250
4700

95 Series
Cyl. Bore
[in]
DA Cyl.
3.50
3.75
4.00
4.25
4.50
4.75
5.00
5.25
5.50
5.75
6.00
6.25
7.00
7.50
8.50
9.00
9.50
10.00
10.50
11.00
12.00
12.50
13.00
13.50
14.00
14.50
15.00
15.50
16.00
16.50
17.00
17.50
18.00
18.50
19.00
19.50
20.00
20.50
21.00
21.50
22.00
22.50
23.50
3.00
3.13
3.25
3.38
3.50
3.62
3.75

Horizontal Couples
Primary Secondary
[Kip*ft]
[Kip*ft]
10.26
10.31
10.38
10.42
10.56
11.06
11.33
11.63
11.91
12.18
12.48
12.83
12.30
12.60
13.34
13.65
14.09
14.84
15.20
15.53
15.88
16.30
16.54
16.79
18.11
18.57
18.82
19.17
19.53
19.87
16.92
17.35
16.76
17.45
17.88
17.67
17.99
18.13
18.25
18.47
18.57
18.62
19.00
10.42
10.46
10.53
10.60
10.67
10.79
10.90

1.28
1.29
1.30
1.31
1.34
1.42
1.47
1.52
1.57
1.61
1.67
1.73
1.64
1.69
1.82
1.87
1.94
2.07
2.14
2.19
2.25
2.33
2.37
2.41
2.64
2.72
2.76
2.82
2.88
2.94
2.43
2.51
2.41
2.52
2.60
2.56
2.62
2.64
2.66
2.70
2.72
2.73
2.79
1.31
1.32
1.33
1.34
1.36
1.38
1.40

Vertical Couples [Kip*ft]


Primary
2.81
Secondary
0.00
Speed
RPM
1200

For D504 - 4 Throw Compressor:


Treat as two 2 throw compressors. Unit A consists of cranks
1 & 2 with equal weights and unit B consists of cranks 3 & 4
with equal weights.
1. Primary Vertical Couple equals 1.414 times the chart value
for unit A or unit B (PV is not dependent on cylinder size).
2. Secondary Vertical Couple equals 0 as in 2 throw case.
3. Primary Horizontal Couple equals 0.707 times the 2 throw
chart value (D502 chart to left) for unit A plus 0.707 times the
chart value (D502 chart to left) for unit B.
4. Secondary Horizontal Couple equals the 2 throw chart value
(D502 chart to left) for unit A minus the 2 throw chart value
(D502 chart to left) for unit B.
Example: D504, 1200 RPM
Cranks 1 & 2 = 9.00 & 5.00 Cylinder (choose 9.00 cylinder, 5.00 is balanced)
Cranks 3 & 4 = 9.00 & 5.00 Cylinder (choose 9.00 cylinder, 5.00 is balanced)
Primary Vertical Couple = 1.414 x 2.81 = 3.97 Kip*ft
Secondary Vertical Couple = 0 Kip*ft
Primary Horizontal Couple = (0.707 x 13.65) + (0.707 x 13.65) = 19.30 Kip*ft
Secondary Horizontal Couple = 1.87 - 1.87 = 0 Kip*ft

Notes:
1. Horizontal primary and secondary forces are zero.
2. Vertical primary and secondary forces are zero.
3. Select cylinder bore with largest unbalance couple. Opposing bore is balanced.
4. For lower speeds, multiply unbalance couple by the square of
the ratio of the desired speed to the rated speed.
5. For any questions contact the GE Gemini Engineering Department @ 1-800-297-4320.

UNBALANCED COUPLES AND FORCES FOR


GEMINI D602 & D604 @ 1200 RPM
Pressure
Rating
PSI
3600

2500

2200

1800
1500

1250

800

635

635

250

250

250

250
4700

95 Series
Cyl. Bore
[in]
DA Cyl.
3.50
3.75
4.00
4.25
4.50
4.75
5.00
5.25
5.50
5.75
6.00
6.25
7.00
7.50
8.50
9.00
9.50
10.00
10.50
11.00
12.00
12.50
13.00
13.50
14.00
14.50
15.00
15.50
16.00
16.50
17.00
17.50
18.00
18.50
19.00
19.50
20.00
20.50
21.00
21.50
22.00
22.50
23.50
3.00
3.13
3.25
3.38
3.50
3.62
3.75

Horizontal Couples
Primary Secondary
[Kip*ft]
[Kip*ft]
12.10
12.16
12.24
12.29
12.49
13.01
13.12
13.58
13.86
14.26
14.53
14.87
14.50
14.86
15.71
16.09
16.59
17.37
17.77
18.15
18.54
19.02
19.28
19.57
21.02
21.54
21.81
22.21
22.62
23.01
19.92
20.37
19.92
20.59
21.07
20.82
21.14
21.20
21.90
21.65
21.77
21.84
22.35
12.20
12.25
12.33
12.41
12.50
12.64
12.78

1.81
1.82
1.84
1.85
1.89
1.99
2.02
2.11
2.17
2.25
2.31
2.38
2.30
2.38
2.55
2.63
2.73
2.90
2.98
3.06
3.14
3.24
3.29
3.35
3.65
3.76
3.82
3.90
3.98
4.06
3.42
3.52
3.42
3.56
3.66
3.61
3.68
3.69
3.83
3.78
3.81
3.82
3.93
1.83
1.84
1.85
1.87
1.89
1.92
1.95

Vertical Couples [Kip*ft]


Primary
3.37
Secondary
0.00
Rated Speed
RPM
1200

For D602 - 4 Throw Compressor:


Treat as two 2 throw compressors. Unit A consists of cranks
1 & 2 with equal weights and unit B consists of cranks 3 & 4
with equal weights.
1. Primary Vertical Couple equals 1.414 times the chart value
for unit A or unit B (PV is not dependent on cylinder size).
2. Secondary Vertical Couple equals 0 as in 2 throw case.
3. Primary Horizontal Couple equals 0.707 times the 2 throw
chart value (D602 chart to left) for unit A plus 0.707 times the
chart value (D602 chart to left) for unit B.
4. Secondary Horizontal Couple equals the 2 throw chart value
(D602 chart to left) for unit A minus the 2 throw chart value
(D604 chart to left) for unit B.
Example: D604, 1200 RPM
Cranks 1 & 2 = 9.00 & 5.00 Cylinder (choose 9.00 cylinder, 5.00 is balanced)
Cranks 3 & 4 = 9.00 & 5.00 Cylinder (choose 9.00 cylinder, 5.00 is balanced)
Primary Vertical Couple = 1.414 x 3.37 = 4.77 Kip*ft
Secondary Vertical Couple = 0 Kip*ft
Primary Horizontal Couple = (0.707 x 16.09) + (0.707 x 16.09) = 22.75 Kip*ft
Secondary Horizontal Couple = 2.63 - 2.63 = 0 Kip*ft

Notes:
1. Horizontal primary and secondary forces are zero.
2. Vertical primary and secondary forces are zero.
3. Select cylinder bore with largest unbalance couple. Opposing bore is balanced.
4. For lower speeds, multiply unbalance couple by the square of
the ratio of the desired speed to the rated speed.
5. For any questions contact the GE Gemini Engineering Department @ 1-800-297-4320.

UNBALANCED COUPLES AND FORCES FOR


GEMINI E502 & E504 @ 1200 RPM
Pressure
Rating
PSI
3600

2500

2200

1800
1500

1250

800

635

635

250

250

250

250
4700

Cyl. Bore
[in]
DA Cyl.
3.50
3.75
4.00
4.25
4.50
4.75
5.00
5.25
5.50
5.75
6.00
6.25
7.00
7.50
8.50
9.00
9.50
10.00
10.50
11.00
12.00
12.50
13.00
13.50
14.00
14.50
15.00
15.50
16.00
16.50
17.00
17.50
18.00
18.50
19.00
19.50
20.00
20.50
21.00
21.50
22.00
22.50
23.50
3.00
3.13
3.25
3.38
3.50
3.62
3.75

Horizontal Couples
Primary Secondary
[Kip*ft]
[Kip*ft]
20.34
20.40
20.48
20.53
20.42
21.04
21.53
21.83
21.96
22.31
22.74
23.08
22.54
22.92
23.86
24.21
24.78
25.71
26.20
26.62
27.05
27.58
27.87
28.19
29.83
30.39
30.70
31.13
31.58
32.00
28.32
29.47
28.61
29.01
29.86
29.62
30.00
30.18
30.16
30.70
31.41
30.62
31.08
20.57
20.62
20.71
20.79
20.88
21.02
21.17

1.98
1.99
2.00
2.00
1.99
2.07
2.14
2.18
2.20
2.25
2.31
2.36
2.28
2.34
2.47
2.52
2.59
2.72
2.79
2.85
2.91
2.98
3.02
3.07
3.29
3.37
3.42
3.48
3.54
3.60
3.09
3.25
3.13
3.18
3.30
3.27
3.32
3.34
3.34
3.42
3.51
3.40
3.47
2.01
2.02
2.03
2.04
2.05
2.07
2.09

Vertical Couples [Kip*ft]


Primary
6.10
Secondary
0.00
Speed
RPM
1200

For E504 - 4 Throw Compressor:


Treat as two 2 throw compressors. Unit A consists of cranks
1 & 2 with equal weights and unit B consists of cranks 3 & 4
with equal weights.
1. Primary Vertical Couple equals 1.414 times the chart value
for unit A or unit B (PV is not dependent on cylinder size).
2. Secondary Vertical Couple equals 0 as in 2 throw case.
3. Primary Horizontal Couple equals 0.707 times the 2 throw
chart value (E502 chart to left) for unit A plus 0.707 times the
chart value (E502 chart to left) for unit B.
4. Secondary Horizontal Couple equals the 2 throw chart value
(E502 chart to left) for unit A minus the 2 throw chart value
(E502 chart to left) for unit B.
Example: E504, 1200 RPM
Cranks 1 & 2 = 9.00 & 5.00 Cylinder (choose 9.00 cylinder, 5.00 is balanced)
Cranks 3 & 4 = 9.00 & 5.00 Cylinder (choose 9.00 cylinder, 5.00 is balanced)
Primary Vertical Couple = 1.414 x 6.10 = 8.63 Kip*ft
Secondary Vertical Couple = 0 Kip*ft
Primary Horizontal Couple = (0.707 x 24.21) + (0.707 x 24.21) = 34.23 Kip*ft
Secondary Horizontal Couple = 3.93 - 3.93 = 0 Kip*ft

Notes:
1. Horizontal primary and secondary forces are zero.
2. Vertical primary and secondary forces are zero.
3. Select cylinder bore with largest unbalance couple. Opposing bore is balanced.
4. For lower speeds, multiply unbalance couple by the square of
the ratio of the desired speed to the rated speed.
5. For E/F 6 throw configuration or any other questions contact the GE Gemini Engineering Department @ 1-800-297-4320.

UNBALANCED COUPLES AND FORCES FOR


GEMINI E602 & E604 @ 1200 RPM
Pressure
Rating
PSI
3600

2500

2200

1800
1500

1250

800

635

635

250

250

250

250

Cyl. Bore
[in]
DA Cyl.
3.50
3.75
4.00
4.25
4.50
4.75
5.00
5.25
5.50
5.75
6.00
6.25
7.00
7.50
8.50
9.00
9.50
10.00
10.50
11.00
12.00
12.50
13.00
13.50
14.00
14.50
15.00
15.50
16.00
16.50
17.00
17.50
18.00
18.50
19.00
19.50
20.00
20.50
21.00
21.50
22.00
22.50
23.50
3.00
3.13
3.25
3.38
3.50
3.62
3.75

Horizontal Couples
Primary Secondary
[Kip*ft]
[Kip*ft]
24.14
24.22
24.32
24.38
24.19
24.93
25.24
25.60
25.93
26.37
26.76
27.45
26.74
27.19
28.26
28.69
29.35
30.31
30.86
31.34
31.81
32.42
32.75
33.10
34.90
35.55
35.89
36.38
36.89
37.37
33.58
33.35
33.89
34.37
35.52
35.24
35.61
35.82
35.55
35.87
36.03
36.11
36.74
24.36
24.42
24.52
24.63
24.73
24.90
25.08

2.80
2.82
2.83
2.84
2.81
2.93
2.99
3.05
3.10
3.17
3.24
3.35
3.24
3.31
3.49
3.56
3.67
3.83
3.92
4.00
4.08
4.18
4.24
4.30
4.60
4.70
4.76
4.84
4.93
5.01
4.38
4.34
4.43
4.51
4.70
4.65
4.71
4.75
4.71
4.76
4.78
4.80
4.90
2.84
2.85
2.87
2.88
2.90
2.93
2.96

Vertical Couples [Kip*ft]


Primary
7.32
Secondary
0.00
Rated Speed
RPM
1200

For E604 - 4 Throw Compressor:


Treat as two 2 throw compressors. Unit A consists of cranks
1 & 2 with equal weights and unit B consists of cranks 3 & 4
with equal weights.
1. Primary Vertical Couple equals 1.414 times the chart value
for unit A or unit B (PV is not dependent on cylinder size).
2. Secondary Vertical Couple equals 0 as in 2 throw case.
3. Primary Horizontal Couple equals 0.707 times the 2 throw
chart value (E602 chart to left) for unit A plus 0.707 times the
chart value (E602 chart to left) for unit B.
4. Secondary Horizontal Couple equals the 2 throw chart value
(E602 chart to left) for unit A minus the 2 throw chart value
(E602 chart to left) for unit B.
Example: D604, 1200 RPM
Cranks 1 & 2 = 9.00 & 5.00 Cylinder (choose 9.00 cylinder, 5.00 is balanced)
Cranks 3 & 4 = 9.00 & 5.00 Cylinder (choose 9.00 cylinder, 5.00 is balanced)
Primary Vertical Couple = 1.414 x 7.32 = 10.35 Kip*ft
Secondary Vertical Couple = 0 Kip*ft
Primary Horizontal Couple = (0.707 x 28.69) + (0.707 x 28.69) = 40.57 Kip*ft
Secondary Horizontal Couple = 3.56 - 3.56 = 0 Kip*ft

Notes:
1. Horizontal primary and secondary forces are zero.
2. Vertical primary and secondary forces are zero.
3. Select cylinder bore with largest unbalance couple. Opposing bore is balanced.
4. For lower speeds, multiply unbalance couple by the square of
the ratio of the desired speed to the rated speed.
5. For E/F 6 throw configuration or any other questions contact the GE Gemini Engineering Department @ 1-800-297-4320.

UNBALANCED COUPLES AND FORCES FOR


GEMINI E702 & E704 @ 1000 RPM
Pressure
Rating
PSI
3600

2500

2200

1800
1500

1250

800

635

635

250

250

250

250
4700

Cyl. Bore
[in]
DA Cyl.
3.50
3.75
4.00
4.25
4.50
4.75
5.00
5.25
5.50
5.75
6.00
6.25
7.00
7.50
8.50
9.00
9.50
10.00
10.50
11.00
12.00
12.50
13.00
13.50
14.00
14.50
15.00
15.50
16.00
16.50
17.00
17.50
18.00
18.50
19.00
19.50
20.00
20.50
21.00
21.50
22.00
22.50
23.50
3.00
3.13
3.25
3.38
3.50
3.62
3.75

Horizontal Couples
Primary Secondary
[Kip*ft]
[Kip*ft]
19.35
19.41
19.49
19.54
19.34
19.94
19.97
20.25
20.66
21.03
21.26
22.04
21.41
21.77
22.59
22.95
23.46
24.12
24.53
24.90
25.25
25.72
25.97
26.24
27.55
28.06
28.31
28.68
29.07
29.43
26.87
25.38
27.10
27.49
28.53
28.30
28.53
28.70
28.29
28.27
27.84
28.74
29.32
19.47
19.52
19.61
19.69
19.77
19.91
20.05

2.61
2.62
2.64
2.65
2.61
2.72
2.73
2.78
2.86
2.94
2.98
3.13
3.01
3.08
3.24
3.31
3.41
3.54
3.62
3.69
3.76
3.85
3.90
3.95
4.20
4.30
4.35
4.42
4.50
4.57
4.07
3.78
4.12
4.19
4.39
4.35
4.39
4.43
4.35
4.34
4.26
4.43
4.55
2.63
2.64
2.66
2.67
2.69
2.72
2.75

Vertical Couples [Kip*ft]


Primary
5.93
Secondary
0.00
Rated Speed
RPM
1000

For E704 - 4 Throw Compressor:


Treat as two 2 throw compressors. Unit A consists of cranks
1 & 2 with equal weights and unit B consists of cranks 3 & 4
with equal weights.
1. Primary Vertical Couple equals 1.414 times the chart value
for unit A or unit B (PV is not dependent on cylinder size).
2. Secondary Vertical Couple equals 0 as in 2 throw case.
3. Primary Horizontal Couple equals 0.707 times the 2 throw
chart value (E702 chart to left) for unit A plus 0.707 times the
chart value (E702 chart to left) for unit B.
4. Secondary Horizontal Couple equals the 2 throw chart value
(E702 chart to left) for unit A minus the 2 throw chart value
(E702 chart to left) for unit B.
Example: E704, 1000 RPM
Cranks 1 & 2 = 9.00 & 5.00 Cylinder (choose 9.00 cylinder, 5.00 is balanced)
Cranks 3 & 4 = 9.00 & 5.00 Cylinder (choose 9.00 cylinder, 5.00 is balanced)
Primary Vertical Couple = 1.414 x 5.93 = 8.39 Kip*ft
Secondary Vertical Couple = 0 Kip*ft
Primary Horizontal Couple = (0.707 x 22.95) + (0.707 x 22.95) = 32.45 Kip*ft
Secondary Horizontal Couple = 3.31 - 3.31 = 0 Kip*ft

Notes:
1. Horizontal primary and secondary forces are zero.
2. Vertical primary and secondary forces are zero.
3. Select cylinder bore with largest unbalance couple. Opposing bore is balanced.
4. For lower speeds, multiply unbalance couple by the square of
the ratio of the desired speed to the rated speed.
5. For E/F 6 throw configuration or any other questions contact the GE Gemini Engineering Department @ 1-800-297-4320.

UNBALANCED COUPLES AND FORCES FOR


GEMINI F502 & F504 @ 1200 RPM
Pressure
Rating
PSI
3600

2500

2200

1800
1500

1250

800

635

635

250

250

250

250
4700

Cyl. Bore
[in]
DA Cyl.
3.50
3.75
4.00
4.25
4.50
4.75
5.00
5.25
5.50
5.75
6.00
6.25
7.00
7.50
8.50
9.00
9.50
10.00
10.50
11.00
12.00
12.50
13.00
13.50
14.00
14.50
15.00
15.50
16.00
16.50
17.00
17.50
18.00
18.50
19.00
19.50
20.00
20.50
21.00
21.50
22.00
22.50
23.50
3.00
3.13
3.25
3.38
3.50
3.62
3.75

Horizontal Couples
Primary Secondary
[Kip*ft]
[Kip*ft]
20.75
20.82
20.90
20.95
20.84
21.45
21.94
22.25
22.38
22.72
23.15
23.49
22.96
23.34
24.27
24.63
25.19
26.13
26.61
27.03
27.47
27.99
28.28
28.60
30.24
30.80
31.11
31.55
31.99
32.42
28.74
29.89
29.03
29.42
30.27
30.04
30.42
30.60
30.57
31.12
31.82
31.03
31.49
20.98
21.04
21.12
21.21
21.29
21.44
21.58

2.03
2.04
2.05
2.06
2.05
2.13
2.20
2.24
2.26
2.31
2.37
2.42
2.34
2.39
2.52
2.57
2.65
2.78
2.85
2.91
2.97
3.04
3.08
3.12
3.35
3.43
3.47
3.53
3.60
3.65
3.14
3.30
3.18
3.24
3.36
3.32
3.38
3.40
3.40
3.47
3.57
3.46
3.53
2.07
2.07
2.09
2.10
2.11
2.13
2.15

Vertical Couples [Kip*ft]


Primary
6.10
Secondary
0.00
Speed
RPM
1200

For F504 - 4 Throw Compressor:


Treat as two 2 throw compressors. Unit A consists of cranks
1 & 2 with equal weights and unit B consists of cranks 3 & 4
with equal weights.
1. Primary Vertical Couple equals 1.414 times the chart value
for unit A or unit B (PV is not dependent on cylinder size).
2. Secondary Vertical Couple equals 0 as in 2 throw case.
3. Primary Horizontal Couple equals 0.707 times the 2 throw
chart value (F502 chart to left) for unit A plus 0.707 times the
chart value (F502 chart to left) for unit B.
4. Secondary Horizontal Couple equals the 2 throw chart value
(F502 chart to left) for unit A minus the 2 throw chart value
(F502 chart to left) for unit B.
Example: F504, 1200 RPM
Cranks 1 & 2 = 9.00 & 5.00 Cylinder (choose 9.00 cylinder, 5.00 is balanced)
Cranks 3 & 4 = 9.00 & 5.00 Cylinder (choose 9.00 cylinder, 5.00 is balanced)
Primary Vertical Couple = 1.414 x 6.10 = 8.63 Kip*ft
Secondary Vertical Couple = 0 Kip*ft
Primary Horizontal Couple = (0.707 x 24.63) + (0.707 x 24.63) = 34.83 Kip*ft
Secondary Horizontal Couple = 2.57 - 2.57 = 0 Kip*ft

Notes:
1. Horizontal primary and secondary forces are zero.
2. Vertical primary and secondary forces are zero.
3. Select cylinder bore with largest unbalance couple. Opposing bore is balanced.
4. For lower speeds, multiply unbalance couple by the square of
the ratio of the desired speed to the rated speed.
5. For E/F 6 throw configuration or any other questions contact the GE Gemini Engineering Department @ 1-800-297-4320.

UNBALANCED COUPLES AND FORCES FOR


GEMINI F602 & F604 @ 1200 RPM
Pressure
Rating
PSI
3600

2500

2200

1800
1500

1250

800

635

635

250

250

250

250
4700

Cyl. Bore
[in]
DA Cyl.
3.50
3.75
4.00
4.25
4.50
4.75
5.00
5.25
5.50
5.75
6.00
6.25
7.00
7.50
8.50
9.00
9.50
10.00
10.50
11.00
12.00
12.50
13.00
13.50
14.00
14.50
15.00
15.50
16.00
16.50
17.00
17.50
18.00
18.50
19.00
19.50
20.00
20.50
21.00
21.50
22.00
22.50
23.50
3.00
3.13
3.25
3.38
3.50
3.62
3.75

Horizontal Couples
Primary Secondary
[Kip*ft]
[Kip*ft]
24.64
24.72
24.82
24.88
24.69
25.42
25.74
26.10
26.43
26.86
27.26
27.95
27.23
27.69
28.75
29.19
29.84
30.81
31.35
31.84
32.31
32.92
33.24
33.60
35.40
36.04
36.38
36.87
37.39
37.86
34.08
33.85
34.39
34.87
36.02
35.74
36.11
36.32
36.05
36.37
36.53
36.61
37.24
24.85
24.92
25.02
25.12
25.23
25.40
25.57

2.89
2.90
2.92
2.93
2.89
3.02
3.07
3.13
3.18
3.26
3.32
3.44
3.32
3.39
3.57
3.64
3.75
3.91
4.01
4.09
4.16
4.27
4.32
4.38
4.68
4.79
4.84
4.93
5.01
5.09
4.46
4.42
4.51
4.59
4.78
4.74
4.80
4.83
4.79
4.84
4.87
4.88
4.99
2.92
2.93
2.95
2.97
2.98
3.01
3.04

Vertical Couples [Kip*ft]


Primary
7.32
Secondary
0.00
Rated Speed
RPM
1200

For F604 - 4 Throw Compressor:


Treat as two 2 throw compressors. Unit A consists of cranks
1 & 2 with equal weights and unit B consists of cranks 3 & 4
with equal weights.
1. Primary Vertical Couple equals 1.414 times the chart value
for unit A or unit B (PV is not dependent on cylinder size).
2. Secondary Vertical Couple equals 0 as in 2 throw case.
3. Primary Horizontal Couple equals 0.707 times the 2 throw
chart value (F602 chart to left) for unit A plus 0.707 times the
chart value (F602 chart to left) for unit B.
4. Secondary Horizontal Couple equals the 2 throw chart value
(F602 chart to left) for unit A minus the 2 throw chart value
(F602 chart to left) for unit B.
Example: F604, 1200 RPM
Cranks 1 & 2 = 9.00 & 5.00 Cylinder (choose 9.00 cylinder, 5.00 is balanced)
Cranks 3 & 4 = 9.00 & 5.00 Cylinder (choose 9.00 cylinder, 5.00 is balanced)
Primary Vertical Couple = 1.414 x 7.32 = 10.35 Kip*ft
Secondary Vertical Couple = 0 Kip*ft
Primary Horizontal Couple = (0.707 x 29.19) + (0.707 x 29.19) = 41.27 Kip*ft
Secondary Horizontal Couple = 3.64 - 3.64 = 0 Kip*ft

Notes:
1. Horizontal primary and secondary forces are zero.
2. Vertical primary and secondary forces are zero.
3. Select cylinder bore with largest unbalance couple. Opposing bore is balanced.
4. For lower speeds, multiply unbalance couple by the square of
the ratio of the desired speed to the rated speed.
5. For E/F 6 throw configuration or any other questions contact the GE Gemini Engineering Department @ 1-800-297-4320.

UNBALANCED COUPLES AND FORCES FOR


GEMINI F702 & F704 @ 1000 RPM
Pressure
Rating
PSI
3600

2500

2200

1800
1500

1250

800

635

635

250

250

250

250
4700

Cyl. Bore
[in]
DA Cyl.
3.50
3.75
4.00
4.25
4.50
4.75
5.00
5.25
5.50
5.75
6.00
6.25
7.00
7.50
8.50
9.00
9.50
10.00
10.50
11.00
12.00
12.50
13.00
13.50
14.00
14.50
15.00
15.50
16.00
16.50
17.00
17.50
18.00
18.50
19.00
19.50
20.00
20.50
21.00
21.50
22.00
22.50
23.50
3.00
3.13
3.25
3.38
3.50
3.62
3.75

Horizontal Couples
Primary Secondary
[Kip*ft]
[Kip*ft]
19.75
19.82
19.89
19.94
19.75
20.34
20.37
20.66
21.07
21.44
21.66
22.44
21.81
22.17
22.99
23.35
23.87
24.52
24.94
25.31
25.65
26.13
26.37
26.64
27.95
28.46
28.71
29.08
29.48
29.84
27.27
25.79
27.50
27.89
28.93
28.70
28.93
29.11
28.70
28.68
28.25
29.14
29.72
19.87
19.93
20.01
20.09
20.18
20.32
20.46

2.69
2.70
2.71
2.72
2.69
2.80
2.81
2.86
2.94
3.01
3.06
3.21
3.09
3.16
3.32
3.39
3.49
3.61
3.70
3.77
3.83
3.93
3.97
4.03
4.28
4.38
4.43
4.50
4.58
4.65
4.15
3.86
4.19
4.27
4.47
4.43
4.47
4.51
4.43
4.42
4.34
4.51
4.63
2.71
2.72
2.74
2.75
2.77
2.80
2.82

Vertical Couples [Kip*ft]


Primary
5.93
Secondary
0.00
Rated Speed
RPM
1000

For F704 - 4 Throw Compressor:


Treat as two 2 throw compressors. Unit A consists of cranks
1 & 2 with equal weights and unit B consists of cranks 3 & 4
with equal weights.
1. Primary Vertical Couple equals 1.414 times the chart value
for unit A or unit B (PV is not dependent on cylinder size).
2. Secondary Vertical Couple equals 0 as in 2 throw case.
3. Primary Horizontal Couple equals 0.707 times the 2 throw
chart value (F702 chart to left) for unit A plus 0.707 times the
chart value (F702 chart to left) for unit B.
4. Secondary Horizontal Couple equals the 2 throw chart value
(F702 chart to left) for unit A minus the 2 throw chart value
(F702 chart to left) for unit B.
Example: F704, 1000 RPM
Cranks 1 & 2 = 9.00 & 5.00 Cylinder (choose 9.00 cylinder, 5.00 is balanced)
Cranks 3 & 4 = 9.00 & 5.00 Cylinder (choose 9.00 cylinder, 5.00 is balanced)
Primary Vertical Couple = 1.414 x 5.93 = 8.39 Kip*ft
Secondary Vertical Couple = 0 Kip*ft
Primary Horizontal Couple = (0.707 x 23.35) + (0.707 x 23.35) = 33.02 Kip*ft
Secondary Horizontal Couple = 3.39 - 3.39 = 0 Kip*ft

Notes:
1. Horizontal primary and secondary forces are zero.
2. Vertical primary and secondary forces are zero.
3. Select cylinder bore with largest unbalance couple. Opposing bore is balanced.
4. For lower speeds, multiply unbalance couple by the square of
the ratio of the desired speed to the rated speed.
5. For E/F 6 throw configuration or any other questions contact the GE Gemini Engineering Department @ 1-800-297-4320.

Potrebbero piacerti anche